DEHUMIDIFIERS /2015 OWNER S MANUAL FOR HEALTHY CLIMATE DEHUMIDIFIER CONTROL MODEL Y6456

Similar documents
Model 75 Dehumidifier Control Owner s Manual

Model 76 Dehumidifier Control Installation Instructions

Model 1870F Dehumidifier Installation and Operating Manual

Model 1850F Dehumidifier Installation and Operating Manual

Model 1820 Dehumidifier

MODEL 1830/1850/1870 DEHUMIDIFIER APPLICATION QUICK START GUIDE

Model 1750A/ 1770A Dehumidifier Installation Instructions

Model 1870 & 1870W Dehumidifier Installation Instructions

Model 65 Humidifier Control Owner s Manual

SmartVent. Digital Controller User Guide Manual. NZ s Home Ventilation Specialists

SmartVent. Keypad Controller User Guide Manual. NZ s Home Ventilation Specialists

Model DEHXXCDA1070 & DEHXXCDA1095 Dehumidifier Installation Instructions

about your house Measuring Humidity in Your Home Figure 1 Do you have a humitity problem? Table 1 Humidity hassles

Control Excess Humidity. Enjoy year-round comfort with whole-home dehumidifiers from Aprilaire

Model 1700 Whole-Home Dehumidifier

Fresh Air Solutions Whole-Home Ventilation

S1-CVD070T01A / S1-CVD095T01A Central Dehumidifier Installation Instructions. Johnson Controls Unitary Products WARNING CAUTION

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.

User Guide: *IG1605EW*

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

IMPORTANT SAFETY INSTRUCTIONS

User Guide: *IG1624EW*

SAS6000UTK-7 UNIVERSAL THERMOSTAT

Buttons on remote controller

20L/D DEHUMIDIFIER Model Number: IG9800

SUKI. Dehumidifier WDH-928DB -20R. User s Manual

CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS

INSTALLER S & OWNER S MANUAL

USER MANUAL. Safety Precautions. Unit Specifications and Features. Operating Instructions. Installation Instructions.

Humidity Solutions Whole-Home Dehumidifiers

Indoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE.

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

Dehumidifier/Dryer. Model: EDV Please read the instruction manual before operating. Keep in a safe place for future reference

User s Manual ELITE PROGRAMMABLE THERMOSTAT WITH MENU DRIVEN DISPLAY

VACUUM CLEANER USER GUIDE

USER GUIDE: COLOR TOUCHSCREEN COMMUNICATING WITH HUMIDITY CONTROL THERMOSTAT. Outside Temperature (if installed) Room Temperature.

Air Conditioning Refrigeration Electrical Work TEL: 0(204) (254)

Using the Remote Control Unit

INSTALLER S & OWNER S MANUAL

VIGÖR HRV PLUS AND VIGÖR ERV

USER GUIDE HEAT RECOVERY VENTILATORS MODELS HRV 90H-V ECM, 90H-V AND 60H NOVO+, MODEL ERV 90H-V ECM PLEASE READ AND SAVE THESE INSTRUCTIONS

Installation, Safety & Maintenance Manual Model 1750A/1770A

Digital Electronic Thermostat With RF

CONTENTS SAFETY PRECAUTIONS. En-1 DANGER! CAUTION!

Safety and Installation Instructions Model 1700

Zone Perfect Plus. Zoning Systems USER S INFORMATION MANUAL. NOTE TO INSTALLER: This manual must be left with the equipment user.

Owner s Manual. Model 8800 Universal Communicating Thermostat. Includes Operating Instructions and Warranty Information

Reducing Allergens and Improving Your Overall Indoor Air Quality

9 LITRE DESICCANT DEHUMIDIFIER INSTRUCTION MANUAL

Instructions manual DEHUMID HP50

USER S MANUAL. Remote Controller 88-MACC007-1A-EN

INSTRUCTIONS Français 2 Nederlands 15 English 28 Italien

DEHUMIDIFIER USER MANUAL 95 PINT FOR MODEL: 3PAD95. Quick Start Tips on Page 1 COMFORT...BUILT TO LAST

Digital Electronic Thermostat With RF

MAINTENANCE SEAL MAINTENANCE PREVENTING WINDOW CONDENSATION. Kohltech.ca

Indoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE.

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW SIMPLE. Read This Manual

OWNER S MANUAL. Portable Dehumidifier: BHD-H Series BHDP-H Series R-410A

USER MANUAL. Portable Air Conditioner and Heater With Heat Pump Technology PAC18. Please read this manual carefully prior to operating the product.

INSTALLATION & USER MANUAL

USER INSTRUCTION MANUAL. Autofill Wall Mount Boilers /12/14

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW CLASSIC

HOMEOWNER S MANUAL. Harmony III Zone Control System. IMPORTANT: Read this instruction manual completely! Retain for future reference.

IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS AIR PURIFIER

INSTALLER S & OWNER S MANUAL

Manual Hygrometer PCE-555

Meaco Platinum Range Instruction Manual

LAF 50 / 100 / 150. Condensing dehumidifiers for professional use. Accessories. Design. Approvals LAF

ATC32U01 igate Communicating, Programmable Thermostat

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

DEHUMIDIFIER USER MANUAL 11 PINT FOR MODEL: 3PAD11 COMFORT...BUILT TO LAST

VMH 09/12/18/24 SD Series Inverter Single Zone Ductless Mini-Split

MD400 Intelligent Dehumidifier with Humidistat and 1.5 litres Tank USER MANUAL

RC-2000 Thermostat Installation Instructions

USER S INFORMATION MANUAL

healthy comfort Indoor Air Quality Solutions

Automation System TROVIS 5400 Ventilation Controller TROVIS Mounting and Operating Instructions EB 5477 EN. Electronics from SAMSON

Air Dehumidification System. Instruction Book CLI-DH8D

CONTENTS SAFETY PRECAUTIONS DANGER! CAUTION!

OWNER'S MANUAL MODEL: D-40ES. For any service needs, call

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

OPERATING MANUAL AIR CONDITIONER CASSETTE TYPE. AUT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

COMFORT CONTROL. Thermidistat Control Homeowner s Guide

Model: S88907 Instruction Manual DC: WIRELESS COLOR WEATHER STATION

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

Important safety information

Owner s Manual MODEL 8555

SAS6000UTK-7-WIFI OPERATING INSTRUCTION

Choosing an Air Cleaner

Model: M Instruction Manual DC: WIRELESS COLOR WEATHER STATION Mold Risk for Weather Station & Indoor Remote Sensor Location

HEALTH. Particles. Chemicals

SPECIFICATIONS for AIR CONDITIONING CONTROLLER ZONE CONTROL

TTK 75 E OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75E-TC-002-EN

Thermo-/Hygrometer with Mould Alert Model WS 1500 Operating Manual

KTX 1, KTX 2, KTX 3, KTX 4. User Manual Electric Heating KTX 1, KTX 2, KTX 3, KTX 4.

DD122 CLASSIC MK5. FOR MORE LANGUAGES, PLEASE VISIT:

USER MANUAL TPS-M5/M55/M555

Model: C Instruction Manual DC: WIRELESS COLOR WEATHER STATION

THERMIDISTAT CONTROL. Homeowner s Guide

Transcription:

DEHUMIDIFIERS 507422-01 11/2015 HEALTHY CLIMATE DEHUMIDIFIER CONTROL OWNER S MANUAL FOR HEALTHY CLIMATE DEHUMIDIFIER CONTROL MODEL Y6456 THIS MANUAL MUST BE LEFT WITH THE HOMEOWNER FOR FUTURE REFERENCE Installed as: EXTERNAL CONTROL or REMOTE CONTROL Installed by: Installer Phone: Date Installed: Thank you for your purchase of the Y6456 Dehumidifier Control. When used as an external control, your control allows you to set the relative humidity level for your home and provides control of the dehumidifier from a convenient living space location. The Y6456 uses an onboard sensor to monitor the relative humidity in the space in which it is located and displays the measured relative humidity on the digital display. The Y6456 can also act as a remote control for your HCWHD3-070, HCWHD3-095, or HCWHD3-130 dehumidifier if it is located in an inconvenient or hard to access area. For example, when the dehumidifier is located in and dehumidifying a crawl space or a basement, the Y6456 can be installed where you spend most of your time, allowing you to make changes to the setting and to see what the humidity is in these areas without having to access the dehumidifier.

Setting the Desired Humidity Level The control will allow you to set the desired humidity level in your home and can be used to turn dehumidification On or Off. LCD Display The materials in a home act like a sponge, so the moisture in the materials of your home is at the same level as the air. After drying the air, the materials of the home will release moisture back into the air until they are again at the same level. As a result, it is not uncommon for the dehumidifier to operate for an extended period of time when first installed. EXTERNAL CONTROL Begin by pressing the ON button and ON will be displayed on the LCD Screen (see LCD display in Figure 1). Use the arrow buttons to set the control at 55% when first installed. Allow the dehumidifier to run for 24 hours before deciding if you want to change the humidity setting. Raise the setting if you prefer the air to be less dry; this will reduce the amount of time that the dehumidifier runs. Lower the setting if you prefer the air to be more dry; this will increase the amount of time that the dehumidifier runs. REMOTE CONTROL Begin by pressing the ON button and ON will be displayed on the LCD Screen (see LCD display in Figure 1). Use the arrow buttons to set the control to a dryness level of 3 when first installed. Allow the dehumidifier to run for 24 hours before deciding if you want to change the dryness level setting. Increase the dryness level setting if you prefer the air to be more dry; this will increase the amount of time that the dehumidifier runs. Decrease the dryness level setting if you prefer the air to be less dry; this will reduce the amount of time that the dehumidifier runs. The dryness level settings can be approximated to relative humidity (%RH) using Table 1. Table 1. %RH (+/-5%) Based on Dryness Level Setting & Indoor Temperature Dryness Level Indoor Temperature ( F) Setting 65 70 75 80 1 84% 71% 60% 2 86% 73% 61% 52% 3 74% 63% 53% 45% 4 64% 54% 45% 39% 5 55% 46% 39% 33% 6 47% 39% 33% 28% 7 40% 34% 28% 24% Note: This table is for reference only. Mode Buttons Use to turn control On/Off. Buttons Use to view and set humidity or dryness level setting. Figure 1. Control Display and User Buttons Energy Savings Tip #1: To reduce dehumidifier run time, when using the Y6456 as an external control, adjust the setting to be as high as is comfortable and when using the Y6456 as a remote control, adjust the setting to be as low as is required for the space. If it feels clammy or smells damp, change the setting to allow for drier conditions. Energy Savings Tip #2: When using the Y6456 as an external control, turn the dehumidifier control OFF when you open your windows, just as you would with air conditioning. Energy Savings Tip #3: When using the Y6456 as an external control, and if vacating your home for an extended period in the summer, set the RH at 59% and set your thermostat to as high as you are comfortable setting it in the cooling mode. Consult with appropriate professionals regarding the highest temperature that is safe for your pets or possessions. This will keep the humidity at a controlled level to help prevent mold while minimizing the amount of cooling energy used. 2 3

LCD DISPLAY TURNING CONTROL ON/OFF Numbers show current room humidity OR humidity setting Solid ON: Control On Blinking ON: Dehumidifying SET is displayed when or is pressed. The value displayed is the humidity setting. See Figure 5. Pressing the ON button will turn on the control. Pressing the OFF button will turn off the control. The control will continue to display the measured humidity when OFF. The humidity or dryness level setting cannot be changed when the control is OFF. Figure 4. ON/OFF Buttons Numbers show remote location humidity OR dryness level setting Solid ON: Control On Blinking ON: Dehumidifying OFF: Control Off OFF: Control Off Blinking ON + : Control Limit Exceeded. * See Control Limits, page 6. Figure 2. External Control LCD Display Figure 3. Remote Control LCD Display SET is displayed when or is pressed. The value displayed is the dryness level. See Figure 7. CHANGING THE HUMIDITY OR DRYNESS LEVEL SETTING The first press of either the or button will display the humidity or dryness level setting on the LCD. Each subsequent push of the up or down buttons will change the setting by 1% or 1 dryness level. If a button is held down, the setting will continually change by 1% or 1 dryness level every 1/2 second for as long as the button is pressed. The control will exit the setting screen 5 seconds after the last button press/release. Figure 5. UP/DOWN Buttons Figure 6. External Humidity Setting Screen 90-1637 Figure 7. Remote Dryness Level Setting Screen 4 5

How Does the Control Work? EXTERNAL CONTROL When the measured humidity is greater than the setting, the control will turn on the dehumidifier and ON will blink on the LCD display. When the measured humidity falls 3% below the setting, the control will turn off the dehumidifier and ON will stop blinking. REMOTE CONTROL The control sends the dryness level to the dehumidifier. Once per Cycle Period (set by your installer in the dehumidifier), the dehumidifier will sample the air in the area served by the dehumidifier. If the dew point of the incoming air is above the dryness level, the dehumidifier will turn on and ON will blink on the LCD display. When the dew point of the incoming air falls below the setting, the dehumidifier will turn off and ON will stop blinking. Control Limits The control limits are used to make sure the dehumidifier does not run when conditions are outside of the operating limits. Dehumidifiers are not as effective when conditions are outside of the operating limits. For example, the dehumidifier will not remove much moisture when conditions are cool and dry. Control limits allow the dehumidifier to work efficiently within the operating range and turn off when conditions are outside of these limits. Dew Point Lower Limit: 40 F External Control Temperature High Limit: 99 F External Control 104 F Remote Control Temperature Low Limit: 50 F Remote Control EXTERNAL CONTROL SEQUENCE OF OPERATION The dehumidifier will turn off if one of the control limits has been exceeded. If the control measures a dew point below 40 F OR a temperature above 99 F, the control will deactivate the dehumidifier output if actively dehumidifying, the dehumidifier will stop dehumidifying, and ON and will blink on the LCD screen (see Figure 2). * The control will resume normal operation when conditions fall back within the control limits. REMOTE CONTROL SEQUENCE OF OPERATION The dehumidifier will turn off if one of the control limits has been exceeded. If the dehumidifier measures a temperature below 50 F or above 105 F, the dehumidifier will stop dehumidifying. The control will resume normal operation when conditions in the remote space fall back within the dehumidifier control limits. Cleaning the Control The surface of the Y6456 Dehumidifier Control can be cleaned with water or a non-abrasive household cleaner, including glass cleaner. Do not spray any liquid directly onto the control. Spray water or a cleaner onto a soft cloth and gently wipe the surface of the control. 6 7

10010836 11.15 B2206365A