HE120, HE160 Humidifier Installation Kit

Similar documents
HE360 Humidifier Installation Kit

HE220, HE260 Humidifier Installation Kit

DS 2001 REVISED Humidifier Assembly and Instruction Manual

CUSTOMER SERVICE. Toll-free:

HE420A Steam Power Humidifier

installation and start-up instructions HUMIDIFIERS AND HUMIDISTAT

HE225A,B and HE265A,B Bypass Flow-Through Humidifier

HE420A,B and HE460A,B Steam Power Humidifiers OWNER S GUIDE

RECOMMENDED LOCATION STEP BY STEP INSTALLATION. MODEL S 200P, 800BP and 97 POWER HUMIDIFIERS

HE360 Powered Flow-Through Humidifier

HE360A,B Powered Flow-Through Humidifier

Installation Instructions

Installation Instructions Owner s Manual

HE365A,B Powered Flow-Through Humidifier

CEILING FAN OWNER'S MANUAL

Installation Instructions. SPANISH Installation Instructions. FRENCH Installation Instructions

T4031A,B,P; T6031A,B Refrigeration Temperature Controllers

FLOW-THROUGH FURNACE HUMIDIFIER

CEILING FAN OWNER'S MANUAL

HUMIDIFIERS OWNERS MANUAL A GUIDE TO OPERATING AND MAINTAINING YOUR HUMIDIFIER 49FH, 49FP, 49BF, 49WS, & 49BG

MODEL HUM HUMIDIFIERS

L A signature series TA T N E RE O, A L L A T S IN

F150E Media Air Cleaner

INSTALLATION. Glass Panel Doors (select models) CAUTION

CEILING FAN OWNER'S MANUAL

THE MONTICELLO CEILING FAN INSTALLATION INSTRUCTIONS

Duct Mount Atomizing Humidifier

CEILING FAN OWNER'S MANUAL

Sunburst. Instruction Manual. Includes our new Wall Control System. A Kichler Décor ceiling fan

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

CEILING FAN OWNER'S MANUAL

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

1. SAFETY RULES. 1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning.

Orrin. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

ChicagoTM. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

52 StarkkTM. Instruction Manual. A Kichler Select ceiling fan

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

F200E Charged-Media Air Cleaner

READ AND SAVE THESE INSTRUCTIONS

60" Hatteras BayTM. Patio. Instruction Manual. Includes our new Wall Control System. A Kichler Décor ceiling fan

LED. 60 StarkkTM. Instruction Manual. A Kichler Select ceiling fan

42 Kevlar. Instruction Manual. Kichler Lighting 7711 East Pleasant Valley Road P.O. Box Cleveland, Ohio

60" Tulle PatioTM. Instruction Manual. A Kichler Select ceiling fan

52 Lacey LED. Instruction Manual. 6 Speed DC Wall Control System

Installation. Leveling

CEILING FAN OWNER'S MANUAL

1. SAFETY RULES WARNING WARNING. 8. Avoid placing objects in the path of the blades.

The T6140A,B Remote Bulb Temperature Controller

60" Lyndon Patio. Instruction Manual Customer Service :30 AM to 5:00 PM EST, Monday - Friday A Kichler Decor ceiling fan

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

T4398A,B Precision Electric Heating Thermostat

CEILING FAN OWNER'S MANUAL

Select. Sutter PlaceTM. Instruction Manual. A Kichler Select ceiling fan

CEILING FAN OWNER'S MANUAL

52 DorsetTM. Instruction Manual. Basic Function Wall Control System Included. A Kichler Decor ceiling fan

Hanson LED C e i l i n g F a n

Hatteras BayTM. Patio. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

CEILING FAN OWNER'S MANUAL

UV100E Ultraviolet Air Treatment System

CEILING FAN OWNER S MANUAL

OWNER S MANUAL AND INSTALLATION GUIDE PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

ValkyrieTM. Instruction Manual. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S.

CEILING FAN OWNER S MANUAL

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE.

Instant Hot Water Dispenser Owner s Manual

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

CEILING FAN OWNER'S MANUAL

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

CEILING FAN OWNER'S MANUAL

Installation Instructions

Easy installation. EZ80N EZ Fit Ventilation Fan INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS. Table of Contents

Installation Instructions

54" Skye. Instruction Manual Customer Service :30 AM to 5:00 PM EST, Monday - Friday A Kichler Decor ceiling fan

CAUTION CAUTION HCWB2 & HCWP2 SERIES IAQ HUMIDIFIERS USER S MANUAL FOR HCWB2 AND HCWP2 HUMIDIFIERS. Table Of Contents

Table of Contents What to Expect with Your Installation. Ceiling Plate. Tools Needed.

SAVE THESE INSTRUCTIONS

Over-the-Range Microwave Oven Installation Instructions MVH130* MVH230* MVH330*

FLOW-THROUGH FURNACE HUMIDIFIER

Installing the Turbo Floor Model System

CEILING FAN OWNER S MANUAL

INSTALLATION INSTRUCTIONS

Read and Save These Instructions

KimberleyTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection.

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Preparation. Wiring. Downrod.

Highland ManorTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection.

FitchTM. Instruction Manual. Includes our Basic Function CoolTouch TM Control System Looks permanent, but goes wherever you go!

CircoloTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection.

TOUCHDOWN 48 CEILING FAN

Installation Instructions for. OmniFount

CEILING FAN OWNER S MANUAL

Installation Instructions

T874 Multistage Thermostat and Q674 Subbase

KD-27A SERIES DISHWASHERS

INSTALLATION INSTRUCTIONS

CAUTION CAUTION HCWB2 & HCWP2 SERIES IAQ HUMIDIFIERS USER S MANUAL FOR HCWB2 AND HCWP2 HUMIDIFIERS. Table Of Contents

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

GE Monogram. Installation. Instructions. Stainless Steel Bottom Mount Built-In Refrigerators. Models ZICS36N RH ZICS36N LH

Transcription:

HE120, HE160 Humidifier Installation Kit INSTALLATION INSTRUCTIONS WELCOME To the comfortable world of humidified air. When you use your Honeywell humidifier, you notice that your skin is not as dry, and that your scratchy throat and irritated nasal passages that aggravate allergies and asthma are steadily improving. You have also taken the first step in reducing the zapping you create when you walk on your carpet and then touch your TV, computer, metal door knob or your pet. Your furniture and woodwork are also benefitting from the difference that humidified air makes. Congratulations! You have just made a great investment in improving the comfort of your home. APPLICATION This installation kit contains all the parts necessary to install your new Honeywell HE120 or HE160 Humidifier. INSTALLATION Preparing for the Installation Be sure to identify all the required (Table 1) accessories (included) and make sure the appropriate tools are available before beginning the installation. Required Accessories (Included) Quantity Table 1. Required Accessories. Accessory 6 ft (1.85M) Bypass ducting including: 6 in. (155 mm) diameter flexible duct Starter collar Summer shut-off damper Duct tape 20 ft (6.2m) 18 gauge, two-strand thermostat wire 20 ft (6.2m) 1/4 in. (6.35 mm) OD feed water tubing 10 ft (3.1m) 3/8 in (9.5 mm) ID overflow tubing 1 bag Connecting and mounting hardware: Wire nuts (4) No. 8 sheet metal screws (18) Overflow tube clamps (2 sizes) Feed tube mounting clamps (6) Brass inserts (2) Plastic compression rings (2) 1 Plug-in transformer 1 Overflow fitting 1 Plastic compression nut Required Tools Tools required for installation include: Tin snip. Screwdriver. Adjustable or open-end wrench. Drill, punch or awl. Level. U.S. Registered Trademark Copyright 2001 Honeywell All Rights Reserved 69-1571

Determining Best Location for Humidifier Select a location for the humidifier on the supply (warm air stream) or the return plenum. See Fig. 1. Select a location for the bypass on the opposite plenum. The humidifier is designed to allow bypass duct mounting on either side of the humidifier. Select a location that cannot damage the air conditioner A-coil during installation. Select a location where the 6 ft (1.86m) of 6 in. (155 mm) duct provided is adequate to connect the humidifier to the bypass. Do not locate the humidifier or bypass on a furnace body. Allow adequate clearance in front of and above the humidifier so you can easily remove the cover to perform routine maintenance. Mount humidifier at least 3 in. (78 mm) above the furnace body to allow adequate space for the drain or overflow line. Mount humidifier in a conditioned space to prevent freezing. For return duct mounting, the humidistat should be mounted upstream from the humidifier or bypass so that it is properly sensing the relative humidity of the living space. Locate the control at least 8 in. (203 mm) upstream from the humidifier in the return air duct. (See Fig 2.) RETURN AIR 6 in. (152 mm) MINIMUM BEST LOCATION RETURN AIR DUCT ALTERNATE LOCATION 15 in. (381 mm) MINIMUM RETURN AIR M12831 Fig. 2. Selecting duct location for humidistat. HORIZONTAL Locating Closest 120V Electrical Outlet Select location with access to an outlet. If not available, contact an electrician to have one installed. Make sure that the 20 ft (6.2m) of thermostat wire is adequate to reach from the humidifier motor to the humidistat, to the plug-in transformer in the outlet. HIGHBOY INSTALLING HUMIDIFIER Fig. 1. Typical humidifier installation locations. Selecting Water Supply Location Use either hard or soft water in the humidifier and either hot or cold water. Make sure that the 20 ft (6.2m) of feed water tubing provided is adequate to connect the water supply (saddle valve) with the humidifier float valve. Locating Closest Floor Drain (If Available) Select location with access to a floor drain (if available); floor drain is optional for safety overflow. Make sure that the 10 ft (3.1m) of overflow tubing is adequate to reach from the humidifier overflow connection to the floor drain. Selecting Location for Humidistat Select a location for the humidistat on the return plenum or on the wall in the living space. LOWBOY DOWN FLO M12248C Mounting on the return plenum is the easiest installation for the control circuit wiring. WARNING Hazardous Voltage. Can cause personal injury or equipment damage. Do not cut or drill into any air conditioning or electrical accessory. CAUTION Sharp Edges Installation Hazard. Can cause personal injury. Wear gloves and safety glasses. 1. Turn off power to the air handing system at the circuit breaker. 2. Draw a level line on the plenum in the location chosen for the humidifier. (Leveling assures optimal humidifier performance.) 3. Locate the template in the Humidifier Installation Instructions. 4. Tape the template in position and trace around the template. 5. Remove the template and carefully cut the rectangular opening. 6. Disassemble the humidifier; remove the cover and take out the disk or drum assembly. See Fig. 4 or 5. Sidecaps are interchangeable for either left or right bypass installation. See device installation instructions. For HE120, go to step 7. For HE160, go to step 13. 69-1571 2

7. Position the HE120 Humidifier base in the opening, mark the five screw holes, and pre-drill the screw holes. 8. Insert the three 3/4 in. (19 mm) sheet metal screws into the top holes. 9. Hang the humidifier over the screws and secure with the two remaining 1/2 in (13 mm) screws. 10. Inside the humidifier housing, where the bypass tube connects, snap the bearing bracket into place with the U-shape of the bracket pointing up. 11. Snap the motor plate into place on the opposite side of the humidifier housing. DISK WHEEL Be sure the motor coupling is positioned toward the top, 12. Place the lead wires through the hole in the bottom of the motor cover and snap the cover into place. For HE120, go to Connecting Plumbing section. For HE160, go to step 13. 13. Hold the hanger bracket against the duct/plenum so the bottom of the hanger bracket is about 1/2 in. (13 mm) from the top edge of the duct/plenum opening. Ensure that it is level and mark the three mounting bolt locations (Fig. 3A). 14. Drill three 3/16 in. (5 mm) holes in the duct/plenum (Fig. 3B). 15. Mount the hanger bracket on the inside of the duct/ plenum using the 3/16 in. (5 mm) machine screws and nuts provided (Fig. 3C). Hanger can be lowered up to 3/4 in. (19 mm) to accommodate larger pre-existing holes. COVER DRAIN CAP Fig. 4. Disassembling disk humidifier. BEARING END OF DRUM SHAFT FLOAT VALVE M20221 DRUM ASSEMBLY A. HOLD HANGER LEVEL AND MARK BOLT HOLE 1/2 IN. LOCATIONS B. DRILL HOLES C. INSTALL HANGER BRACKET INSIDE PLENUM/DUCT M20220 Fig. 3. Mounting HE160 on plenum. 16. Hang the basin from the mounting hanger and secure with the sheet metal screws provided. 17. Insert the screws into the pilot holes and through to the back of the bracket. 18. Snap the motor plate and inlet into the basin. Be sure the tabs fit into the corresponding basin slots. 19. Install the drain and cap at the bottom of the basin, with the cap on the outside of the humidifier housing. Hand-tighten until the drain does not turn; do not overtighten. HUMIDIFIER HOUSING WATER PAN WATER VALVE OPENING Fig. 5. Disassembling drum humidifier M12252 CONNECTING PLUMBING 1. Install the float into the slot in the side of the basin. Hand-tighten the nut. For HE120, attach the float on the same side as the motor; install the plug in the opposite slot. 2. Shut off the water. (Either hot or cold water and either hard or softened water can be used in the humidifier.) 3 69-1571

CAUTION Chemical Hazard. Can cause personal injury or equipment damage. Do not use any line connected to an air conditioner. Do not use gas line. 3. Use the self-piercing saddle valve (included) to tap into the water supply line at the location selected. See Fig. 6. If tapping into galvanized pipe, drain line and pre-drill 3/16 in. tap for saddle valve. The saddle valve is not designed to regulate water flow. The valve is either open or closed. d. Insert the tubing into the float valve fitting and support the valve while tightening the compression nut. Do not over-tighten the compression nut. Moderate tightness prevents leaking. e. Repeat steps a. through d. for saddle valve fitting. f. Secure tubing with clamps provided. BRASS COMPRESSION NUT PLASTIC COMPRESSION RING BRASS INSERT IMPORTANT To prevent debris from clogging the solenoid inline filter, be sure to install the saddle valve handle pointing toward the ceiling. SCREW DRIVER M20176 WATER LINE Fig. 7. Installing feed tubing. 5. Connect a 3/8 in. (10 mm) overflow tube to the humidifier overflow fitting and run to the floor drain or bucket if floor drain is not available. a. Insert overflow fitting. (HE160 fitting is provided in the kit. HE120 fitting is provided with humidifier; position it in hole opposite of float.) M20175 Be sure to install water pan with overflow positioned over fitting. Fig. 6. Installing saddle valve. 4. Use 1/4 in. (6 mm) OD tubing and connect saddle valve to float valve (see Fig. 7). For HE120, use plastic compression nut for float connection. a. Place compression nut over tubing. For HE160, use brass expander insert for float connection. b. Install brass insert into end of tubing. A compression ring is required only at the tub end connected to the saddle valve. c. Slide the plastic compression ring over the tubing. (Discard copper compression ring provided with valve.) To prevent leaking, use plastic (Delrin) sleeve rings with plastic tubing. Use copper sleeve rings only with copper tubing. b. Slide the overflow clamp over the tubing. c. Push the tubing over the overflow fitting on the humidifier. d. Hand-tighten the clamp around the tubing to secure the overflow tubing. e. Fasten the overflow tubing (can use duct tape) along the route to prevent movement and ensure downward slope for correct drainage. Cut tubing to correct length so the tubing terminates at the drain or bucket. Adjusting HE160 Water Level (Fig. 8) 1. Test fit the disk assembly in the humidifier. 2. Turn on the water supply and check for leaks. 3. Adjust the float assembly so the water height just covers the disks; verify that the water is within the range of the textured bands inside the basin. 4. Adjust the float, as necessary. 5. Secure the float adjustment nut with a 9/16 in. (15 mm) wrench. 6. Remove the disk and drain the water before beginning the bypass installation. 69-1571 4

ENSURE TABS ON INLET AND MOTOR PLATE FIT INTO SLOTS IN LID FLANGES SUMMER WINTER WATER Fig. 8. Adjusting HE160 water level. OVERFLOW HOLE FLOAT ADJUSTMENT SLOT M20222 INSTALLING BYPASS 1. Use inside of the 6 in. (155 mm) starter collar as a template to mark the opening for the bypass. 2. Carefully cut the 6 in. (155 mm) opening for the starter collar. See Fig. 9. Use a drill, punch or awl to start the cut in the middle of the circle. Cut in an outward spiral to assist in controlling the cut. M20173 Fig. 10. Installing starter collar. 4. Remove liner to expose foam adhesive. Position starter collar over opening. 5. Using sheet metal screws, connect starter collar to the duct and bypass duct from humidifier to starter collar. Be sure to secure the collar to the duct with sheet metal screws. See Fig. 11. STARTING HOLE 6 IN. ROUND TEMPLATE M20223 Fig. 11. Connecting bypass ducting. Fig. 9. Cutting bypass opening. M20172 3. Assemble the summer shutoff damper into the starter collar. Verify that the damper rotates freely between the open and closed positions. Make sure handle will be accessible. Mark the damper closed position as summer and the open position as winter. See Fig. 10. IMPORTANT To avoid sagging and stress on humidifier, add support if ducting is longer than 4 ft (1.25m). 6. Seal the duct connections with duct tape. 7. Reinstall the humidifier drum or disk assembly in the humidifier housing. 8. Install the humidifier lid. 5 69-1571

Humidity Control Régulateur d'humidité OUTDOOR TEMPERATURE -20 F -30 C -10 F -25 C 0 F -20 C +10 F -10 C +20 F -5 C Over 20 F Over 0 C HUMIDITY SETTING 15% 20% 25% 30% 35% 40% HE120, HE160 HUMIDIFIER INSTALLATION KIT INSTALLING HUMIDISTAT Mounting Duct 1. Apply the template to the duct location chosen for the humidistat. Make sure the template is level before drilling the holes. 2. Refer to the template (provided with the H8909 Humidistat Installation Instructions) to drill the control assembly opening and mounting holes for the H8908. 3. Remove the H8908 case from the base. 4. Position the foam gasket on the H8908 base. 5. Position the base on the duct with the arrow up. 6. Secure the base to the duct using the four 1 in. (25 mm) mounting screws provided with humidistat. 7. Connect the low-voltage wires to the leads and replace the H8908 case. See Fig. 12. For wall mounting instructions, see the H8908 Installation Instructions. HUMIDIFIER DRIVE MOTOR BLACK WHITE TRANSFORMER WHITE BLACK Fig. 13. Wiring the controls. HUMIDISTAT M20224 1. Run the two-strand thermostat wire from the humidifier to the transformer, from the transformer to the humidistat. 2. Cut lengths of thermostat wire to reach between components, leaving adequate wire at both ends for connections. HUMIDISTAT BASE REAR OF HUMIDISTAT Transformer and humidistat can be wired in any order. 3. At the humidifier, connect the black and white conductors to the two motor leads. 4. At the transformer, connect both black conductors to the two transformer terminals. Use a wire nut to connect the white conductors. 5. At the humidistat, connect the black and white conductors to the two humidistat terminals. WIRE SLOT HUMIDISTAT WIRES M20179 TESTING HUMIDIFIER OPERATION WIRING Fig. 12. Humidistat base and rear view. CAUTION Hazardous Voltage. Can cause personal injury or equipment damage. Disconnect power supply before installing or servicing equipment. IMPORTANT All wiring must comply with applicable local code, ordinances and regulations. Wire the humidifier motor, humidistat and transformer. See Fig. 13. Checklist Humidifier is level. Starter collar is secured with sheet metal screws. Summer shut-off damper is open (in winter position). Control wiring was reviewed using circuit diagram. Transformer is plugged in. Feed line has no kinks. Overflow line slopes continuously down and ends at floor drain or bucket. After installation use the following steps to check the humidifier operation: 1. Turn on the power and the water supply. For HE160, see Adjusting Water Level section. 2. Verify that basin fills and float shuts off before water enters overflow tubing. 3. Turn the H8908 Humidity Control to On. 4. Make sure that drum or disk turns. 5. Check for leaks. 6. Reset the H8908 Humidity Control to a comfortable setting for automatic operation. 69-1571 6

TROUBLESHOOTING YOUR HUMIDIFIER (TABLE 2) HE120, HE160 HUMIDIFIER INSTALLATION KIT Table 2. Troubleshooting Humidifier. Problem What to look for What to do Water leakage Leaking joints Shut off water. Tighten connections. Brass tubing inserts Saddle valve leaking Verify that brass tubing inserts are used. Verify rubber pad is installed on saddle valve. No water to basin. Electrical Verify control circuit wiring. Check all connections. Humidistat Transformer Plumbing Saddle valve Float valve Turn humidistat up and down and listen for contact to click. Verify that outlet has power. Verify plumbing connections. Check for kinks. Verify that needle pierced water line and then back out needle to open valve. Remove cover and verify that float is moving freely. Air leakage Check duct joints Seal with duct tape. Water flowing into overflow Device level Float valve Level device. Check for free movement of float arm. Adjust water level of float. 7 69-1571

Home and Building Control Home and Building Control Honeywell Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Scarborough, Ontario M1V 4Z9 69-1571 G.H. 09-01 Printed in U.S.A. on recycled paper containing at least 10% www.honeywell.com/yourhome post-consumer paper fibers.