Rheem Classic Series Downflow/ Horizontal Gas Furnaces

Similar documents
Ruud Acheiver Series Upflow Gas Furnaces

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES CLASSIC 95% A.F.U.E. HIGH EFFICIENCY UPFLOW GAS FURNACES

GAS FURNACES SELECT 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES. RGRK- SERIES Models with Input Rates 120,000 BTU/HR [35.17 kw] (All Models 90% A.F.U.E. or Above)

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY UPFLOW GAS FURNACES

Rheem Classic Plus Series Two Stage Multi position Gas Furnaces

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

Rheem Classic Plus Series Multi position Gas Furnaces

Rheem Classic Series Multi-position Gas Furnaces

GAS FURNACES 90 PLUS WITH DUAL COMFORT CONTROL TWO-STAGE UPFLOW GAS FURNACES

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.

COMFORT CONTROL 90 PLUS WITH DUAL TWO-STAGE UPFLOW GAS FURNACES

GAS FURNACES. Visit taxcredit for complete details.

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

Ruud Achiever Plus Series Multi-position Gas Furnaces

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. )

90TJ SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to kw] (All Models 90% A.F.U.E. or Above)

TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. )

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )

MULTI POSITION GAS FURNACE

Rheem Prestige Series Two-Stage Downflow Gas Furnace equipped with the Comfort Control 2. System. RGLE- Series 80% A.F.U.E. Input Rates kbtu

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

Rheem Prestige Series Modulating Horizontal Gas Furnace equipped with the Comfort Control 2. System

Multi-Position Gas Furnaces

MULTI POSITION GAS FURNACE

80% A.F.U.E. DOWNFLOW GAS FURNACES

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES

GAS FURNACES. ACHIEVER SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES w/ecm MOTOR

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

GAS FURNACES. RGFD- SERIES Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58 to kw] (All Models 92% A.F.U.E.

Rheem Prestige Series Communicating Two-Stage Variable Speed Multi-Position. Gas Furnaces

GAS FURNACES 90 PLUS COMMUNICATING MODULATING DOWNFLOW GAS FURNACES EQUIPPED WITH THE COMFORT CONTROL 2 SYSTEM AND

GAS FURNACES. RGFD- SERIES Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58 to kw] (All Models 92% A.F.U.E.

Rheem Prestige Series EcoNet Enabled Modulating Upflow Gas Furnaces

Ruud Achiever Series Multi position Gas Furnaces

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES

Multi-Position Gas Furnaces

Rheem Prestige Series Communicating Two-Stage Variable Speed Downflow Gas Furnace

GAS FURNACES. Communicating Furnace Thermostat. FORM NO. G Supersedes Form No. G RHC-TST550CMMS MID HIGH

GAS FURNACES 90 PLUS COMMUNICATING MODULATING UPFLOW GAS FURNACES EQUIPPED WITH THE COMFORT CONTROL 2 SYSTEM AND CONTOUR COMFORT CONTROL

GAS FURNACES II 78% A.F.U.E. UPFLOW GAS FURNACES CRITERION

GAS FURNACES SILHOUETTE II PLUS 2 LXE TWO STAGE 80% A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

COMMUNICATING TWO-STAGE VARIABLE SPEED MULTI-POSITION GAS FURNACES

Ruud Ultra Series EcoNet Enabled Two-Stage Variable Speed Multi- Position Gas Furances

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace

Hydronic Air Handler Powered by Tankless Technology

Rheem Classic. Series Highboy & Lowboy Oil Furnaces with PSC/Direct Drive Motor

Hydronic Air Handler Powered by Tankless Technology

OIL FURNACES PREMIUM CLASS UPFLOW OIL FURNACES. ROBF- SERIES Heating Capacities 56,000 to 151,200 BTU/HR [16.41 to kw]

Hydronic Air Handler Powered by Tankless Technology

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

INTEGRATED HVAC & WATER HEATING

TECHNICAL SPECIFICATIONS

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

G6RC Series TECHNICAL SPECIFICATIONS

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

RG7D 1-Stage Heat Series

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

TECHNICAL SPECIFICATIONS

Rheem Air Handlers. RHML- Series X-13 (ECM) Motor

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

Rheem Standard Efficiency Air Handler

Rheem Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

FG7T (C and L Series)

Comfort, Quality and Efficiency.

Hydronic Air Handler Powered by Tankless Technology

Rheem Air Handler. RHBL- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RHAL- Series PSC Motor Efficiencies up to 14.5 SEER

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

Energy Saving. Space Saving.

TECHNICAL SPECIFICATIONS

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY

Ruud Standard Efficiency Air Handler

Cooling Capacity CFM in. w.c. (125 Pa)

Rheem High Efficiency Air Handler

Ruud Standard Efficiency Air Handler

Ruud Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

Wt. Lbs Model Number (BTUH) Hz

Rheem High Efficiency Air Handler

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM range

TECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 92 AFUE DESCRIPTION WARRANTY FEATURES Rev.

H9MPV. 2- Stage Variable Speed 90. Flexibility. Quality. Comfort. Efficiency. Service (7/2004)

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Ruud High Efficiency Air Handler

Gas Furnaces. Gas Furnaces. 2-Stage Variable-Speed. 2-Stage Multi-Speed Multipoise. Multipoise 80AFUE. 2-Stage Variable-Speed Multi-Speed Multipoise

Transcription:

Gas Furnaces Rheem Classic Series Downflow/ Horizontal Gas Furnaces RGTC- Series Up to 95% A.F.U.E. Input Rates from 45 to 105 kbtu [13.19 to 30.77 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy test procedures. The Rheem Classic 90 Plus High Efficiency line of down - flow/hori zontal gas furnaces are designed for utility rooms, closets, alcoves, attics or crawl spaces. The RGTC is shipped in the downflow configuration and is easily converted for horizontal left-hand airflow applications. The design is certified by CSA. Heat exchanger is constructed of all stainless steel for maximum corrosion resistance and thermal fatigue reliability. Low profile 34 inch design is lighter and easier to handle and leaves room for optional accessories. Top electrical connections, left or right gas and condensate drainage connections on downflow models. Condensate drain for horizontal application provided standard. Integrated control board manages all operational functions and provides hookups for humidifier and electronic air cleaner. An insulated blower compartment, a slow-opening gas valve and a specially designed inducer system make it one of the quietest furnaces on the market today. Pre-paint galvanized steel cabinet. Molded permanent filters. Optional indoor or outdoor combustion air. Transformer and control fuse protection. Control board diagnostics. A variety of cooling coils and plenums designed to use with the Classic 90 Plus gas furnaces are available as optional accessories for air conditioning models. FORM NO. G11-526

Table of Contents TABLE OF CONTENTS Standard & Optional Equipment...3 Physical Data & Specifications...4 Model Number Identification...5 Dimensional Data...6-7 Blower Performance Data...8 Accessories...9 Limited Warranty...10 2

Standard & Optional Equipment INTEGRATED FURNACE CONTROL FUSE PROTECTION PRESSURE SWITCH DRAFT INDUCER GAS VALVE AND MANIFOLD PRIMARY AND SECONDARY HEAT EXCHANGER DIRECT SPARK IGNITION IN-SHOT BURNERS STANDARD EQUIPMENT Completely assembled and wired; heat exchanger; primary: 409 and aluminized 409 stainless steel, secondary: 29-4C stainless steel; induced draft; pressure switch; redundant main gas control; blower compartment door safety switch; solid state time on/off blower control; limit controls; manual shut-off valve; 100% safety lock out; cool fan off delay; field selectable heat fan off delay; one hour automatic retry; power and selftest diagnostics; flame sense current diagnostics; electronic air cleaner connections; twinning (built-in) features; humidifier connections; humidifier on/off delay; low speed continuous fan option; single speed option for heating and cooling applica - tions; transformer; direct drive, multi-speed blower motor. (Please note: a thermostat is not included as standard equipment.) REMOTE SENSOR OPTIONAL EQUIPMENT NOTE: Furnace is not listed for use with fuels other than natural or L.P. (propane) gas. All models can be converted by a qualified distributor or local service dealer to use L.P. (propane) gas without changing burners. Factory approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optional accessories from a parts distributor. For L.P. (propane) operation, refer to Conversion Kit Index Form. WARNING THIS FURNACE IS NOT APPROVED OR RECOMMENDED FOR USE IN MOBILE HOMES 3

Physical Data & Specifications Physical Data and Specifications Downflow/Horizontal Models U.S. and Canadian Models MODEL NUMBERS RGTC-04EMAES RGTC-06EMAES RGTC-07ERBGS RGTC-09EZAJS RGTC-10ERBJS INPUT-BTU/HR [kw] ➀ 45,000 [13.19] 60,000 [17.58] 75,000 [21.98] 90,000 [26.38] 105,000 [30.77] HEATING CAPACITY BTU/HR [kw] 43,000 [12.61] 58,000 [16.99] 72,500 [21.25] 87,000 [25.50] 101,500 [29.75] HIGH ALTITUDE INPUT [kw] ➁ 40,500 [11.87] 54,000 [15.83] 67,500 [19.78] 81,000 [23.74] 94,500 [27.70] HIGH ALTITUDE OUTPUT CAPACITY [kw] ➁ 37,000 [10.84] 50,400 [14.77] 63,000 [18.46] 75,000 [21.98] 87,500 [25.64] BLOWER (D x W) [mm] 11 x 7 [279 x 178] 11 x 7 [279 x 178] 11 x 10 [279 x 254] 12 x 11 [305 x 279] 11 x 10 [279 x 254] MOTOR H.P. [W] SPEEDS-TYPE 1/2 [373]-4-PSC 1/2 [373]-4-PSC 1/2 [373]-4-PSC 3/4 [559]-4-PSC 3/4 [559]-4-PSC MOTOR FULL LOAD AMPS 6.8 6.8 6.8 9.5 9.5 HEATING SPEED MED-LOW MED-HI MED-HI MED-HI MED-HI COOLING SPEED HIGH HIGH HIGH HIGH HIGH HEAT EXT. STATIC PRESSURE (IN. W.C.) [kpa].10 [.025].12 [.029].12 [.029].15 [.037].20 [.049] RATED EXT. STATIC PRESSURE (IN. W.C.) [kpa].50 [.124].50 [.124].50 [.124].50 [.124].50 [.124] HEATING CFM @.2" W.C. E.S.P. [L/s] 866 [409] 1122 [530] 1516 [716] 1698 [802] 1812 [856] COOLING CFM @.5" W.C. E.S.P. [L/s] 1220 [576] 1242 [586] 1559 [736] 1850 [873] 1977 [934] TEMPERATURE RISE RANGE F [ C] 30-60 [16.7-33.3] 30-60 [16.7-33.3] 30-60 [16.7-33.3] 30-60 [16.7-33.3] 35-65 [19.4-36.1] STANDARD FILTER [mm] (2) 12" x 20" [305 x 508] (2) 12" x 20" [305 x 508] (2) 12" x 20" [305 x 508] (2) 12" x 20" [305 x 508] (2) 14" x 20" [356 x 508] APPROX. SHIPPING WEIGHT (LBS.) [kg] 123 126 137 148 160 AFUE ➂ 95.0% 95.0% 95.0% 95.0% 95.0% NOTES: All models are 115V, 60HZ, 1ø. Gas connection size for all models is 1 /2" [13 mm] N.P.T. ➀ See Conversion Kit Index Form for high altitude derate. ➁ Canadian installations only. ➂ In accordance with D.O.E. test procedures. [ ] Designates Metric Conversions 4

Model Number Identification Model Number Identification R G T C 06E M A E S Rheem Gas Furnace Downflow/ Horizontal Condensing Gas Furnace Design Series Electric Ignition 04E 06E 07E 09E 10E Heating Input Designation Input BTU/HR 45,000 [13 kw] 60,000 [17.6 kw] 75,000 [20.5 kw] 90,000 [26.4 kw] 105,000 [30.7 kw] Blower Size M = 11 x 7 [279 x 178 mm] R = 11 x 10 [279 x 254 mm] Z = 12 x 11 [305 x 279 mm] Variations A = Std. B = Wide Cabinet Heat/Cool Designation E = 1100-1300 CFM [519-613.5 L/s] G = 1500-1700 CFM [707.9-802.3 L/s] J = 1900-2100 CFM [896.7-991.1 L/s] Fuel Code S = U.S. and Canadian Natural Gas [ ] Designates Metric Conversions 5

Dimensional Data MINIMUM CLEARANCE (IN.) [mm] SHIP MODEL LEFT A B C D E F WGTS. RGTC- SIDE RIGHT BACK TOP FRONT VENT SIDE [kg] 04 17 1 /2 [445] 16 11 /32 [415] 15 5 /8 [397] 2 [51] 16 5 /8 [422] 13 7 /8 [352] 0 0 0 1 [25] 2 [51] 0 123 [56] 06 17 1 /2 [445] 16 11 /32 [415] 15 5 /8 [397] 2 [51] 16 5 /8 [422] 13 7 /8 [352] 0 0 0 1 [25] 2 [51] 0 126 [57] 07 21 [533] 19 27 /32 [504] 19 3 /16 [486] 2 [51] 20 1 /8 [511] 17 3 /8 [441] 0 0 0 1 [25] 2 [51] 0 137 [62] 09 21 [533] 19 27 /32 [504] 19 3 /16 [486] 2 [51] 20 1 /8 [511] 17 3 /8 [441] 0 0 0 1 [25] 2 [51] 0 148 [67] 10 24 1 /2 [622] 23 11 /32 [593] 22 5 /8 [575] 2 [51] 23 5 /8 [600] 20 7 /8 [530] 0 0 0 1 [25] 2 [51] 0 160 [73] [ ] Designates Metric Conversions IMPORTANT NOTE: Horizontal furnace may be installed for horizontal left hand air supply ONLY. The condensate trap provided for horizontal application must be installed in the field beneath the unit as directed in the furnace Installation & Operating Instructions. 6

Dimensional Data [ ] Designates Metric Conversions IMPORTANT NOTE: Horizontal furnace may be installed for horizontal left hand air supply ONLY. The condensate trap provided for horizontal application must be installed in the field beneath the unit as directed in the furnace Installation & Operating Instructions. 7

Blower Performance Data MODEL RGTC- 04 06 07 09 10 BLOWER SIZE IN. [mm] 11 x 7 [279 x 178] 11 x 7 [279 x 178] 11 x 10 [279 x 254] 12 x 11 [305 x 279] 11 x 10 [279 x 254] MOTOR H.P. [W] 1/2 [373] 1/2 [373] 1/2 [373] 3/4 [559] 3/4 [559] BLOWER SPEED LOW MED-LO MED-HI HIGH LOW* MED-L0 MED-HI HIGH LOW* MED-L0 MED-HI HIGH LOW* MED-L0 MED-HI HIGH LOW* MED-L0 MED-HI HIGH NOTE: Recommended heating blower speeds are in bold. *Not allowed for heating speed tap. NOTE: CFM values represent furnace-only airflow ratings. CFM [L/s] AIR DELIVERY EXTERNAL STATIC PRESSURE INCHES WATER COLUMN [kpa] 0.1 [.02] 0.2 [.05] 0.3 [.07] 0.4 [.10] 0.5 [.12] 0.6 [.15] 0.7 [.17] 794 [375] 890 [420] 1110 [524] 1383 [653] 816 [385] 924 [436] 1164 [550] 1409 [665] 1126 [532] 1338 [632] 1555 [734] 1743 [823] 1213 [573] 1504 [710] 1734 [819] 2111 [997] 1324 [625] 1617 [764] 1842 [870] 2204 [1041] 765 [361] 866 [409] 1084 [512] 1350 [638] 792 [374] 895 [423] 1122 [530] 1367 [646] 1097 [518] 1309 [618] 1516 [716] 1696 [801] 1196 [565] 1474 [696] 1698 [802] 2059 [972] 1309 [618] 1505 [753] 1812 [856] 2153 [1017] 735 [347] 842 [398] 1057 [499] 1317 [622] 767 [362] 866 [409] 1080 [510] 1325 [626] 1068 [504] 1280 [604] 1477 [698] 1649 [779] 1179 [557] 1443 [681] 1662 [785] 2007 [948] 1294 [611] 1573 [743] 1781 [841] 2102 [993] 704 [332] 811 [383] 1023 [483] 1274 [602] 739 [349] 832 [393] 1044 [493] 1284 [606] 1036 [489] 1253 [592] 1440 [680] 1604 [757] 1158 [547] 1415 [668] 1621 [766] 1946 [919] 1272 [601] 1533 [724] 1728 [816] 2040 [963] 672 [317] 779 [368] 989 [467] 1230 [581] 711 [336] 798 [377] 1008 [476] 1242 [586] 1003 [473] 1225 [579] 1402 [662] 1559 [736] 1136 [536] 1387 [655] 1579 [746] 1885 [890] 1250 [590] 1493 [705] 1674 [791] 1977 [934] 633 [299] 750 [354] 946 [447] 1171 [553] 686 [324] 754 [356] 966 [456] 1195 [564] 963 [455] 1185 [560] 1349 [637] 1501 [709] 1108 [523] 1348 [637] 1526 [721] 1821 [860] 1221 [577] 1448 [684] 1619 [765] 1905 [900] 594 [281] 721 [341] 902 [426] 1112 [525] 661 [312] 710 [335] 923 [436] 1148 [542] 923 [436] 1145 [541] 1295 [612] 1442 [681] 1079 [510] 1308 [618] 1472 [695] 1756 [829] 1191 [562] 1402 [662] 1564 [739] 1833 [866] [ ] Designates Metric Conversions 8

Accessories VENT TERMINATION KITS CONCENTRIC: HORIZONTAL/ VERTICAL = RXGY-E03A (US & Canadian Installations) HORIZONTAL TWO PIPE: RXGY-D02, RXGY-D03, RXGY-D04 (US Installations) RXGY-D02A, RXGY-D03A, RXGY-D04A (Canadian Installations) RXGY-G02 (US Only) CONDENSATE PUMP KIT: RXGY-B01 NEUTRALIZER KIT: RXGY-A01 COMBUSTIBLE FLOOR BASE: RXGC-B17 RXGC-B21 RXGC-B24 EXTERNAL FILTER RACK: RXGF-CC MODEL RGTC- FILTER RACK FILTER SIZES* INCHES [mm] RXGF-CC 04 (2) 12 x 20 [305 x 508] 06 (2) 12 x 20 [305 x 508] 07 (2) 12 x 20 [305 x 508] 09 (2) 12 x 20 [305 x 508] 10 (2) 14 x 20 [356 x 508] *Filter racks are shipped without filters. Filters shipped with furnace may be used or a suitable 1" [25.4 mm] filter. [ ] Designates Metric Conversions PLENUM DATA FOR A COILS Plenum adapters are required in some instances for use on downflow applications when plenum and furnace size do not match. FURNACE WIDTH IN. [mm] PLENUM WIDTH IN. [mm] PLENUM ADAPTER DOWNFLOW COIL PLENUM 17 1 /2 [445] 16 1 /4 [413] RXAA-C186 RXAL-B16BU 17 1 /2 [445] 20 1 /4 [514] RXAA-C173 RXAL-B20BU 17 1 /2 [445] 21 5 /8 [549] RXAA-C187 RXAL-B21BU 17 1 /2 [445] 25 1 /4 [641] RXAA-C174 RXAL-B25BU 21 1 /2 [533] 25 1 /4 [641] RXAA-C175 RXAL-B25BU 21 1 /2 [533] 22 1 /4 [565] RXAA-C176 RXAL-B22BU 21 1 /2 [533] 21 5 /8 [549] RXAA-C188 RXAL-B21BU 24 1 /2 [622] 25 1 /4 [641] RXAA-C177 RXAL-B25BU 24 1 /2 [622] 21 5 /8 [549] RXAA-C187 RXAL-B21BU FOSSIL FUEL KIT: RXPF-F01 FOR HIGH ALTITUDES RXPF-F02 (TVA) NOTE: For Canadian installations only, an optional derate (manifold gas pressure reduction) method may be used to adjust the furnace for altitude. See Installation Instructions for more information. This optional method may NOT be used for U.S. installations. FOR LEFT SIDE (ALTERNATE) CONDENSATE DRAIN KIT: RXGY-H01 (All Models) 9

Limited Warranty GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty. *For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate. Conditional Parts (Registration Required)...Ten (10) Years Heat Exchanger...Limited Lifetime 10

Notes 11

The new degree of comfort. In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Heating, Cooling & Water Heating P.O. Box 17010 Fort Smith, Arkansas 72917 www.rheem.com Rheem Canada Ltd./Ltée 125 Edgeware Road, Unit 1 Brampton, Ontario L6Y 0P5 PRINTED IN U.S.A 03/12 QG FORM NO. G11-526