Installation Instructions Owner s Manual

Similar documents
RECOMMENDED LOCATION STEP BY STEP INSTALLATION. MODEL S 200P, 800BP and 97 POWER HUMIDIFIERS

HE220, HE260 Humidifier Installation Kit

HE360 Humidifier Installation Kit

HE120, HE160 Humidifier Installation Kit

DS 2001 REVISED Humidifier Assembly and Instruction Manual

Installation Instructions. SPANISH Installation Instructions. FRENCH Installation Instructions

CUSTOMER SERVICE. Toll-free:

Installation Instructions

MODELS HUM HUMIDIFIERS. Form No. PDS HUM.56.1 HUMBBLFP1025-A-- HUMBBSFP1016-A-- HUMBBLBP2018-A-- HUMBBWTR2019-A-- HUMBBSBP2017-A--

installation and start-up instructions HUMIDIFIERS AND HUMIDISTAT

CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS

Product Data. HUM Humidifiers

FLOW-THROUGH FURNACE HUMIDIFIER

Product Data. 49FH, 49FP, 49BF, 49WS, 49BG Humidifiers

Continue to next pages for Template instructions, Owners Guide, Humidistat Instructions.

Wiring Instructions. High-Capacity Steam Humidifiers

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Product Data. HUM Humidifiers. FEATURES/BENEFITS (Bypass & Fan Powered Models) FAN POWERED MODELS BYPASS MODELS STEAM MODEL

Duct Mount Atomizing Humidifier

FLOW-THROUGH FURNACE HUMIDIFIER

Installation Instructions & Owner's Manual

Residential Steam Humidifier

Installation Instructions

OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

HEALTHY CLIMATE HUMIDIFIER

READ AND SAVE THESE INSTRUCTIONS OWNER S MANUAL FOR BYPASS AND FAN POWERED HUMIDIFIERS. Small or Large Bypass 12 Water Saver Bypass 13 Fan Powered 14

G-100ES Duct Mount Humidifier

Integrated Ventilation System

L A signature series TA T N E RE O, A L L A T S IN

Product Data. HUM Humidifiers FEATURES/BENEFITS

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be

Installation Electric Dryers Instructions 01

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL

WineZone Ceiling Mount Ductless Split 15

LZP-2 ZONE CONTROL PANEL

RSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2

SAFETY AND INSTALLATION MANUAL MODEL 8100

Steam Humidifier Fan Pack Installation & Maintenance Instructions

RSIF Power Venter USA CAN. Product Information. ... Chapters Mechanical Installation. ... Chapter 3. Electrical Installation. ...

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

MODELS HUM HUMIDIFIERS. Form No. PDS HUM Model HUMBBLFP1318 FEATURES/BENEFITS. Model HUMBBLBP2317. Model HUMBBSBP2312

INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY

CAUTION CAUTION HCWB2 & HCWP2 SERIES IAQ HUMIDIFIERS USER S MANUAL FOR HCWB2 AND HCWP2 HUMIDIFIERS. Table Of Contents

Model 8120 and 8126 Safety & Installation Instructions

INSTANT HOT WATER DISPENSER

Questions on Installation? Call: GECARES (US) or Visit our Web site at: (US) 4" DUCT CLAMPS (2) OR 4" SPRING CLAMPS (2)

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

Easy installation. EZ80N EZ Fit Ventilation Fan INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS. Table of Contents

INSTALLATION INSTRUCTIONS

Installation Instructions Preference Wall Mount Range Hood

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

G-100ES Duct Mount Humidifier

Model DEHXXCDA1070 & DEHXXCDA1095 Dehumidifier Installation Instructions

BYPASS AND POWER HUMIDIFIER OWNER S MANUAL

Installation Instructions

Installation Instructions

Model Smart Digital Humidistat

Model 1820 Dehumidifier

Installation Instructions Wall Ovens

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

Downdraft Raised Vent

INSTALLATION INSTRUCTIONS FOR 7370A736 FLUSH MOUNT CEILING PLENUM

Installation Instructions

RV Products Division INSTALLATION INSTRUCTIONS FOR SERIES PACKAGE AIR CONDITIONER

Dryer. User manual DV22K6800** DV22K A-00_EN (US)_ indd :15:41

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

MODEL HUM HUMIDIFIERS

CAUTION CAUTION HCWB2 & HCWP2 SERIES IAQ HUMIDIFIERS USER S MANUAL FOR HCWB2 AND HCWP2 HUMIDIFIERS. Table Of Contents

INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

e Bath Fan with Light User s Guide

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

Model 1750A/ 1770A Dehumidifier Installation Instructions

Duct Mounted Atomizing Humidifier. Table of Contents

Installation Instructions Remote Blowers

B.C.S. Shop Heaters 26, 30 & 36 (36 shown)

INSTALLATION INSTRUCTIONS FOR 6797A737 HEAT PUMP FLUSH MOUNT CEILING PLENUM

INSTALLATION INSTRUCTION

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

24 VAC SYSTEM CONTROL KIT

TOTALINE HUMIDIFIERS HUMIDIFIES TOTALINE GOLD FLOW-THROUGH HUMIDIFIER

for the Programmable Humidifier Automatic Flushing Timer

VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED

Product Data. HUM Humidifiers FEATURES/BENEFITS

TOUCHDOWN 48 CEILING FAN

Installation Instructions

READ AND SAVE THESE INSTRUCTIONS HUMIDIFIERS USER S INFORMATION GUIDE. For Models *HUMD200ABM00B *HUMD300ABA00B *HUMD500APA00B

OUTDOOR DISHWASHER INSTALLATION INSTRUCTIONS

Installation Instructions

24 VAC SYSTEM CONTROL KIT

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier

Oil Furnace USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE

Duct Mount Rotating Drum Humidifier

ST. KITTS CEILING FAN

HE365A,B Powered Flow-Through Humidifier

DISHWASHER INSTALLATION GUIDE SPECIFICATIONS, INSTALLATION, AND MORE

Automatic Digital Humidifier Control

Transcription:

Installation Instructions Owner s Manual FOR USE WITH GAS, OIL and HYDRONIC FORCED AIR FURNACES SEQUENCE OF OPERATION The AUTOFLO Model s SC15 & 250 use the evaporative principal to add moisture to the warm air heating system. Upon a demand for Humidity from the Humidity Control, the water solenoid valve opens and water flows in at the top of the media pad and is evaporated, as warm air passes through the media pad. When the moisture laden air re-enters the duct it is mixed with the dry air already flowing through the duct. This moisture laden air gradually increases the relative humidity level in the home. RECOMMENDED LOCATION TEMPERATURE AND SAFETY REQUIREMENTS Refer to the rating plate on the furnace for minimum clearances to combustible construction. All parts and connections of an AUTOFLO humidifier must be installed outside of the minimum clearance requirements for rear, top, sides, and flue of furnace. Do not install where humidifier or water connections may be exposed to freezing temperatures or outside weather. Attic installations are not recommended. If you have central air conditioning, carefully plan the location of the plenum opening to prevent damage to the cooling coil or other components inside the duct. HUMIDIFIER MOUNTING LOCATION The AutoFlo model SC-15, is to be mounted on the supply duct of the furnace only. Model 250 can be mounted on the supply or the return duct of the furnace. HUMIDISTAT MOUNTING LOCATION The humidistat can be mounted on the cold air return duct to sense the cool dry air returning to the furnace. It can also be mounted on an interior wall near the furnace thermostat as well. The electrical connections and basic wiring are the same for duct mounted or wall mounted humidistats. TB 218 Part # 090375A0218 Rev. B MODEL SC-15 & MODEL 250 FLOW-THRU HUMIDIFIERS STEP BY STEP INSTALLATION CAUTION: Installation should be performed by qualified personnel only. Use eye protection and gloves when drilling and handling sheet metal. All work must be performed to local & national codes and ordinances. Use multi-conductor 18 awg solid copper wire. Provide over-current protection as required. DO NOT omit the drain or overflow tubing. DRILL MOUNTING HOLES AND CUT OPENING MODEL SC-15 Turn off power to the furnace before installing the humidifier. Test Fit the SC15 housing on the side of the warm air plenum. Before proceeding, verify that adequate clearances are available for servicing the media pad. There must also be adequate room ( 5 ½ inches) inside the plenum for the louver. If necessary, relocate the unit. Use a plumb line or a level to make sure the housing is level. With a permanent marker outline the inside edge of the housing. Also mark the twelve holes to be drilled. Center punch and drill all twelve holes as indicated by the marks. Drill or punch a starter hole and then use tin snips to cut out the rectangular shaped opening. The opening should be 1/8 inch larger on all four sides than what was marked. MOUNTING HUMIDIFIER Hold the housing next to duct and start four #8 x ¾ inch long sheet metal screws through the holes in the bottom edge of the humidifier. With these four screws started the unit should remain in place while starting the other eight screws. With all twelve of the screws started they can now be tightened. With the housing mounted the louver can be installed. This should be done by rotating the louver to the proper position depending on the direction of air flow. The airflow should enter into the curved multi-louvers and exit out of the large opening. E-Mail- info@ ewccontrols.com

MODEL SC-15 & MODEL 250 FLOW-THRU HUMIDIFIERS SC-15 SC-15 mounts to the supply duct only. Horizontal flow Blower Motor Up Flow Place Baffle Here Supply Duct BYPASS Horizontal flow 250 Return Duct Side Cutaway View Model SC-15 mounted on the supply plenum of an Upflow Furnace SC-15 250 250 DRILL MOUNTING HOLES AND CUT OPENING MODEL 250 Mount the model 250 using all the same precautions as in mounting the SC-15. Use the mounting template to locate the humidifier on the duct work. Tape down the template for the humidifier and for the bypass duct adaptor. Drill and cut all holes that go with each template. Mount the adaptor and the baffle with the (6) 3/8 screws from the kit. Mount the humidifier by first putting in the bottom of the humidifier housing to catch the lip on the back of the housing. Then use the (10) 1/2 screws that come in the kit to mount the housing to the duct. Install the field supplied bypass duct and end cap. First route the bypass duct from the duct adaptor to one side of the humidifier housing. Drill 2 holes through the bypass duct and the duct adaptor. Install (2) 3/8 screws from the kit on each end of the humidifier housing. there are pre- punched holes. Use them to line up and mount the bypass duct and end cap with (2) 1/2 screws from the kit. Open the Bypass Baffle during the Winter and Close it during the Summer. Return Duct Up Flow Mounting the Model 250 Model 250 Bypass Baffle and duct adaptor. Supply Duct Down Flow

PARTS LIST Unpack the Autoflo model SC-15 Humidifier and familiarize your self with the following parts: 1. Model SC-15 Humidifier 2. Parts bag containing: A. Twelve #8 x 3/4 inch sheet metal screws B. Two #8 x 3/8 inch sheet metal screws 3. Saddle Valve Tapping kit 4. 24 volt humidistat 5. 24 volt transformer 6. 1/2 drain hose 7. 1/4 plastic water tubing 8. Evaporative media pad 9. Owner s manual ADDITIONAL RECOMMENDED PARTS 1. Relay, with 120 volt current sensing coil for furnaces with multi-speed blower motors. 2. 4x4 wire box to mount transformer and enclose line voltage connections 3. #18awg thermostat wire to make up any and all 24 volt connections. 4. 1/2 drain hose clamp.

PARTS LIST Un-pack the Autoflo model 250 humidifier and familiarize yourself with the following parts. 1. Model 250 humidifier 2. Evaporative pad with holder 3. Mounting template(not Shown) 4. 24 volt transformer 5. 1/4 plastic water tubing 6. Saddle Valve Tapping kit 7. Six #6 x 1/2 sheet metal screws 8. Sixteen #8 x 3/8 sheet metal screws 9. By-pass adaptor template(not Shown) 10. Baffle 11. End cap 12. Duct adaptor 13. Two wire nuts(not Shown) 14. 1/2 inch drain tubing 15. 24 humidistat 16. Owner s manual ADDITIONAL REQUIRED OR RECOMMENDED PARTS 1. Bypass Duct material 6 Diameter metal. 2. Relay, with 120 volt current sensing coil for multi-speed blower motors. 3. 4x4 wire box to mount transformer. To enclose line voltage connections. 4. # 18 awg thermostat wire to make up any and all 24 volt connections 5. 1/2 drain hose clamp.

MODEL SC-15 & MODEL 250 FLOW-THRU HUMIDIFIERS ELECTRICAL CONNECTIONS. The transformer should be wired in parallel with the furnace blower motor line voltage. This will allow the humidifier to run only when there is a call for fan. The transformer is designed to be attached to a 4 square outlet box. The electrical box must be mounted and wired in accordance with local building codes & the National Electrical Code. SHUT OFF THE POWER TO THE FURNACE BEFORE PROCEEDING! NOTE1: Check wiring in furnace for humidifier (HUM) terminals. If present, check to see if it is 120vac or 24vac. If it is 120vac connect the transformer primary leads to these terminals. If it is 24vac, you don t need the transformer. Simply connect one side of the humidistat to one HUM terminal and the other HUM terminal to the solenoid valve of the humidifier. Then make the last connection of the solenoid to the humidistat. If you are using the transformer you will need to connect the 24 vac common from the transformer to one of the solenoid valve wires and then the 24vac hot from the transformer to the humidistat. Then from the humidistat to the other wire on the solenoid valve. Make sure not to route wires where they can be burned or chaffed. See example wiring solutions to the right of this page. OPERATIONAL CHECK With the humidistat set to its highest setting the humidifier solenoid should open shortly after the furnace blower is activated. If solenoid does not open refer to troubleshooting guide in this manual. WIRING FOR MOST COMMON FURNACES HUMIDISTAT Solenoid Valve on Model SC15 or 250 To Motor current sensing relay NO Contact H H C T40-VA 24VAC 40VA OR EQUIVALENT WIRING FOR COMMON 2 STAGE OR VARIABLE SPEED FURNACES HUMIDISTAT C T40-VA 24VAC 40VA OR EQUIVALENT L1 L2 TO LINE VOLTAGE To 120vac HUM terminals in furnace. See Note 1. HUM CAUTION: Check the transformer, the solenoid valve and humidistat as well as all field wiring connections as they could be at fault. A qualified Electrician should be consulted to determine if 24 VAC is present at the solenoid and at the humidistat, and that line voltage is present at the transformer. Solenoid Valve on Model SC15 or 250 HUM If the HUM terminals in the furnace are 24vac, don t use the transformer! Simply connect to the HUM terminals as shown.

MODEL SC-15 & MODEL 250 FLOW-THRU HUMIDIFIERS INSTALL HUMIDISTAT The AutoFlo Humidistat should be installed as described in the installation instructions supplied with the humidistat. WATER CONNECTIONS Water supply for the humidifier should be taken from a nearby hot water line but cold water is acceptable. All water connections should be made at ground floor level. Do not use any water line served by a water softener. If your home has a water softener, make the connection up stream of the water softener. A water softener is not a demineralizer. It merely exchanges various hard-ions for soft-ions in the water. These soft-ions or minerals, will build up in the transfer media in the humidifier, causing the need for more frequent servicing. The evaporation of softened water may produce a white powder which may be carried through the duct system and ultimately in to the home. The saddle tapping valve should be mounted on top of, or on the side of the water line. If the valve is installed on the bottom of the water line it could clog with sediment from the water line. Refer to the instructions on the saddle valve package and proceed as follows. For copper water lines the valve is self piercing. Mount the saddle valve to top or side of water line, then turn T handle to the clockwise until it stops to pierce and seat the valve to the pipe. Open to flush the valve and close it again. Then connect plastic water line from the valve to the humidifier making sure not to kink it or run it near any hot flue pipes. Connect water line to valve and humidifier with supplied hardware. Now open the saddle valve turning the tee handle counter clockwise until fully open. Check for water leaks and repair as necessary. Attic installations are not recommended. DRAIN CONNECTION Connect the ½ inch plastic tubing to the drain spout and secure it. The spout is located at the bottom of the housing. Keep the tubing as short as possible and avoid sharp bends. The drain line should be routed on a continuous downward slope and into a suitable drain. WARNING: Failure to connect the drain tubing could result in a flood. INSTALL DOOR AND EVAPORATIVE PAD Make sure the evaporative pad is positioned in the door correctly. The black mark on the edge of the pad indicates the top. The pad slides into the door and rests against the four legs located inside. Position the bottom edge of the door in the tray located on the lower opening in the housing. Then simply push top of door closed until it has snapped in to place. To remove door just push down on the two tabs located at the top of the door and pull the door away from the housing. SETTING THE HUMIDISTAT Most people feel comfortable between 35% to 45% RH but the proper relative humidity for your home depends upon many factors such as outside air temperature, type and placement of insulation, vapor barrier, effectiveness of weather stripping, type of windows and doors (including frames and jams)and whether storm windows and doors are used. With all these variables it is nearly impossible to recommend a proper humidity setting. The best humidistat setting is one that you are comfortable with. Also, as the outdoor temperature fluctuates, it may be necessary to adjust the humidiy level a few times during the heating season. Refer to the Relative Humidity Chart as a starting point for your proper humidistat setting. Generally, in a tighter and better-insulated house, the humidistat may be set higher than in a drafty, uninsulated house. You may prefer to purchase an Optional #072000 Autoflo Humidity Control which will sense the outdoor temperature and automatically adjust the RH level in the home, as the outdoor temperature changes. Contact the sales department or visit us at www.ewccontrols.com to find out all there is to know about the 072000 Smart Humidistat.

DO NOT OVER-HUMIDIFY Cold air cannot hold as much moisture as warm air. Any cold drafts or cold-faces such as windows and doors (including frames and jams) may cause water vapor to condense at these points. Also, if your home is well-insulated and weatherstripped but lacks effective vapor barriers, water may seep through the walls and ceilings. This moisture may condense either inside or outside the walls or in the attic. If any of these condition are observed, the humidity should be reduced before water damage occurs. All power humidifiers require some maintenance to keep them operating at peak performance. The AUTOFLO has been designed to simplify required maintenance. For the MODEL SC-15 1. Semi-annual or Annual replacement of the evaporator pad. 2. An annual cleaning, general inspection, and shut down of the unit at the end of the heating season. 3. The evaporative pad should be replaced when it starts to look white and chalky replace it with a catalog # SC-EP pad. OUTDOOR TEMPERATURE o +30 F o +20 F o +10 F o +0 F o -9 F ADJUST %RH TO 40% 35% 30% 25% 20% For the MODEL 250 1. Semi-annual or Annual replacement of the evaporator pad. 2. An annual cleaning, general inspection, and shut down of the unit at the end of the heating season. The replacement pad catalog # is 40ep for pad with holder. Table 1. Suggested RH set points for different outdoor temperatures.

T R O U B L E S H O O T I N G SYMPTOM POSSIBLE CAUSES Water doesn t flow when solenoid is energized. 1. Saddle Valve T handle is not open. 2. Saddle Valve is clogged with mineral buildup. 3. Solenoid valve inlet screen is clogged. 4. Solenoid valve is stuck closed. Solenoid will not energize. 1. Humidity control is not set high enough. 2. Control transformer has failed. 3. HVAC system is not in the heating mode. 4. Fan motor interlock is faulty or miswired. 5. Faulty or incorrect field wiring. 6. Solenoid coil is faulty. No water flows out of the drain tube. 1. Drain tube is kinked or blocked with debris. RH level in the home is low or will not rise. 1. Humidity control is set to low. 2. Water supply has been turned off. 3. Media pad is clogged with mineral buildup. 4. Media panel is installed incorrectly. 5. Solenoid valve is not opening or is faulty. 6. Heating system is drying out the house faster than the humidifier can replace it. A sign of extremely cold outside temperatures or the unit is undersized for the space. 7. Obtain a reliable & accurate Hygrometer to determine the RH level in the home. TECHNICAL SUPPORT EWC Controls provides superior toll free Troubleshooting Support for the AUTOFLO products when you are on the job site! Call 1-800-446-3110 Monday - Friday 8am to 5pm EST Otherwise call 1-732-446-3110 for information on the MODEL SC-15 or. MODEL 250 or any other AUTOFLO products When calling for Technical Support, please have a multi-meter, pocket screwdriver, and wire cutter/stripper handy.