DAYLIGHTING ANALYSIS. Generic Design/Analysis Methods (applicable to all sorts of systems)

Similar documents
Daylight and Whole-Building Energy Analysis Using Radiance in IES <Virtual Environment>

Windows Influence on Room Daylighting in Residential Buildings

Buidling 661 Annual Daylight Performance Modeling Studies

Advanced Lighting For Office

NRG SYSTEMS, HINESBURG, VT

University of California Santa Barbara. Student Resource Building

Schematic Design Proposal Presentation

SMEAL COLLEGE OF BUSINESS BUILDING University Park, PA

354: Composing with Light: An inside-out Evaluation of the Role of Intuition and Simulation throughout the Design Process

Lord Stirling Community School

Lighting Control Strategies. to meet code requirements save energy and improve building performance

Guidelines for sizing roof windows

Depth Work Part 1: Lighting Design

POTENTIAL ENERGY SAVINGS WITH EXTERIOR SHADES IN LARGE OFFICE BUILDINGS AND THE IMPACT OF DISCOMFORT GLARE. Sabine Hoffmann, Eleanor Lee

Lighting Depth: Courtyard Franklin Care Center, Franklin Lakes, NJ

Knowledge Based Expert System Computer Aided Climate Responsive Integrated Approach to Architectural Design

Lighting Application Guide for K-12 Classrooms

Are LED s ready for Prime Time?

BAINBRIDGE ISLAND MUSEUM OF ART

Course Syllabus LIGHTING DESIGN

Annual environmental performance evaluation of light and heat in daylight harvesting systems using Radiance and NewHASP

Fast. Precise. Versatile. UL Lighting Sciences

A home that grows with its residents. Transforming an old house into a family home for the future

VEROSOL sun control blinds

HARRY RANSOM HUMANITIES RESEARCH CENTER

Thomas Brown, Architect, LEED-AP. Part 4 Daylighting Strategies Glazing Resources

Cosmetology Lab Redesign

KAPSARC Competition Entry. Riyadh, Saudi Arabia

NEW CD WARP CONTROL SYSTEM FOR THE CORRUGATING INDUSTRY

MANDATORY MEASURES. There are two major steps for exterior spaces to comply with Title 24:

ANNIVERSARY

Shepherd University Wellness Center AE 481 Revised Thesis Proposal

THE GLARE EVALUATION METHOD FOR CIVIL AIRPLANE FLIGHT DECK

Lighting Existing Conditions and Design Criteria Report EXECUTIVE SUMMARY

Clare Hall daylight in window design

A new model for CEN/TC 89 Thermal performance of buildings and building components

EVALUATING DAYLIGHT PERFORMANCE IN A PASSIVE SOLAR HOME: A STUDY BASED ON DESIGN SIMULATION AND POST- OCCUPANCY MONITORING RESULTS

Lecture 8 OPENINGS &ORGANIZATION OF FORM AND SPACE

Carpenter Center Cambridge, MA DAYLIGHT AS A DESIGN FACTOR Anahita Anandam

11.0. Design Manual: Sustainable Initiatives. Chapel Hill Streetscape and Lighting Master Plan mikyoung kim design all rights reserved.

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

3. Desk lamps are generally 12 to 20 high and are used to light a specific work area.

Optimizing the Radiance Workflow: In an Integrated Firm Environment

Developing Early Design Simulation Tools For Persons with Vision Impairments

California s 2008 Building Energy Efficiency Standards for Residential and Nonresidential Buildings

Lindsey Beane. Executive Summary

Advances in Non-Residential Lighting Technologies

Optimal control for superior lighting performance

Lighting Existing Conditions and Design Criteria Report

VENTILATIVE COOLING CONTROL STRATEGIES APPLIED TO PASSIVE HOUSE IN ORDER TO AVOID INDOOR OVERHEATING

Energy Using Products Directive: Implementation of Lot 17

Lighting Existing Conditions and Design Criteria Report

Code Compliance. Lightcloud. Guides for California Title 24 & ASHRAE

BUG stands for Backlight, Uplight and Glare. The acronym

Daylighting Control Design and Application Guide

DEVELOPMENT DESIGN GUIDELINES

PRINCIPLES OF HEATING, VENTILATION AND AIR CONDITIONING with Worked Examples

LIGHTING EXISTING CONDITIONS SUMMARY EXECUTIVE SUMMARY Sara Lappano Ltg./Elec. Corron Cultural Center Middletown, VA

Technical Report IVb: Proposal

Center for Health Research and Rural Advocacy

Copyright 2017 Integrated Environmental Solutions Limited. All rights reserved.

Jennifer Mers. Rio Hondo Library and Learning Resource Center. Executive Summary. General Building. Lighting/Electrical Option

Exterior Façade Lighting Design

Prof. Lee In-Hee, Faculty of Architecture, PNU.

Shepherd University Wellness Center AE 481 Thesis Proposal

Technical Report One

ISOLIEREN & GESTALTEN MIT GLAS SANCO

English Version. Daylight of buildings

MANDATORY MEASURES DAYLIGHTING. (Reference: Sub-Chapter 4, Section 130)

Engineering Simulation in Built Environment and Civil Engineering Projects

A New Federal Office Building for San Juan, Puerto Rico. Project Total Square Footage: 167,505 sf. Anticipated Date of Completion: November 2018

Thesis Proposal Update #2

An exciting lighting tour of Japan: Experience how Japan utilises lighting design and technology into city lighting projects

Available online at ScienceDirect. Procedia Engineering 155 (2016 )

1. Avoid extensive blank walls that would detract from the experience and appearance of an active streetscape.

Information paper 18. Prepared by: David Clark. book:

Lobby Lighting Design

Monterey Downtown Lighting Strategy

Home Designer HOME DESIGN SOFTWARE

The forecast will always be clear and cool. Pilkington Activ and Pilkington Activ Blue Self-cleaning and Solar Control Glass for conservatories

ISO 9050 INTERNATIONAL STANDARD

13-15, 2001 USING LIGHTING SIMULATION TO ASSESS THE PERFORMANCE OF AND INDIRECT OFFICE LIGHTING SYSTEMS IN DYNAMIC WORKPLACES

DAYLIGHTING PERFORMANCE ON VENETIAN BLIND FOR HEALTHY APARTMENT HOUSING

Rethinking Bexley Hall

Recent BRANZFIRE enhancements and validation

Perot Museum of Nature and Science Final Lighting Design Presentation. Yucheng Lu, Lighting Electrical, Adviser: Shawn Good

Duke University Medical School. Duke School of Nursing

Steve Neimeister 8 October 2003 AE 481W AstroPower Headquarters Newark, Delaware Lighting/Electrical Option Consultant: M. Moeck

ARTICLE XVI LIGHTING, NOISE AND ODOR/ODOROUS MATTER Shelby County Zoning Regulations 2013

Architectural Engineering Lighting/Electrical Option

BUILDING MANAGEMENT SYSTEMS. Introduction to Building Management Systems

FR-A180 FR-A360. Occupancy detector. Use

Albany Senior Center Remodel

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

THEODORE ROOSEVELT SENIOR HIGH SCHOOL WASHINGTON,DC

Lighting Concepts: Residential

Vernonia K-12 School: Thermal Comfort in Passively-Cooled Zones

Existing Area Description: The area is an angle around the North point of the building. It is a wide patio wrapping the façade of the building.

Heat Transfer in Evacuated Tubular Solar Collectors

Main Lobby Area (North Vestibule thru South Vestibule):

Transcription:

DAYLIGHTING ANALYSIS www.interactivearchitecture.org/lightmodulator-nick-rich.html Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 1 Generic Design/Analysis Methods (applicable to all sorts of systems) Rules/patterns/precedents Simple to use; little input information is required; results have limited accuracy; such methods are typically used to establish best first design moves First principles Looking to the laws of physics for analysis procedures; very difficult for complex systems due to multiple interactions between numerous variables Correlation methods Can appear complex, but intended to be relatively simple to use; some specific input information is required (namely, the correlating parameters); can give fair accuracy; typically used to refine first design moves Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 2

Generic Design/Analysis Methods Digital simulation methods Computer software programs crunching numbers; simulations may use correlations or (more commonly) first principles; lots of specific input information is required; accuracy can be exceptional (or not remember the junk in, junk out rule); historically used as a design refinement tool, but there is a strong trend in practice toward use in the early stages of the design process Analog methods Object-based using scale models; the extent of required input information varies with the accuracy desired; accuracy can be great (and is a direct function of model accuracy); can be used as both a first-moves and as a design-refinement tool Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 3 Generic Design/Analysis Methods Rules/patterns/precedents I can replicate this First principles www.useefficiency.eu I can solve this equation www.slideshare.net Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 4

Generic Design/Analysis Methods Correlation methods I can handle 10 variables expanding-sketchup.blogspot.com Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 5 Generic Design/Analysis Methods Digital simulation methods I have the data (and knowledge) to complete the input files www.tboake.com www.lowenergystudio.com Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 6

Generic Design/Analysis Methods Analog methods I can make it www.boora.com www.educate-sustainability.eu Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 7 Daylighting Patterns: Getting Started The 2.5H rule This empirical rule predicts that useful daylight will penetrate a space to a distance of 2.5 times the height (H) of a window (above the work plane) assuming a window width of about 50% of the wall width and an overcast sky (the sky type may not be critical, however, as this is a rough rule) The 15/30 rule Suggests that a 15-foot-deep zone inward from a window (the wall plane) will receive adequate daylight for office work, the next 15 feet (to 30 feet total) will receive some daylight (to be supplemented with electric lighting), after 30 feet there is not much daylighting assuming no intervening opaque partitions Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 8

Daylighting Patterns: Getting Started Rough estimations For sidelighting DF average = 0.2 (window area/floor area) DF minimum = 0.1 (window area/floor area) For toplighting Clerestory DF average = 0.2 (glazing area/floor area) Horizontal skylight DF average = 0.5 (skylight area/floor area) compare these two results as with all such estimates, a reasonable design layout is assumed Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 9 More-Refined Daylighting Prediction/Validation Methods BRS daylighting protractors (consisting of drawing overlays) CIE method (involving many charts) IES lumen method (similar to the zonal cavity method used with electric lighting) Computer simulations (many programs are available) Physical models Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 10

BRS Protractors (Correlation) these are transparent overlays that are used in conjunction with plan and section drawings Building Research Station (UK) for overcast sky conditions daylighting units are read off overlays; rarely used in the US, but the graphic approach can inform design thinking (see next slide) Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 11 BRS Protractors note that this approach graphically defines the extent of sky resources available at any given point within a building forget the overlay and just do the sketch! Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 12

CIE Method (Correlation) input output CIE (Europe) for overcast sky conditions DF is read from chart; rarely used in the US Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 13 CIE Method vs. LEED & 2.5H note that a 60% window area, in a 30 foot wide room, with a room depth of 2.5H yields an initial 2% minimum DF (as required by LEED-NC 2.1) Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 14

IES Lumen Method (Correlation) IESNA (from L-O-F) (USA) -- obsolete overcast sky conditions? this method is similar to a commonly used electric lighting design method Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 15 Daylighting Software (may be correlation or first principles) numerous software packages are readily available for overcast and clear sky conditions electric light integration usually included early example of daylighting software Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 16

Daylighting Software Ecotect (and then part of Autodesk; and now??) Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 17 Daylighting Software photo-realistic rendering developed in Radiance (from LBL) image from Arup Lighting Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 18

Daylighting Software questions to ask: -- does a program do daylighting analysis or just direct solar? -- what is the learning curve like? -- what is the required input? (too little = inaccurate; too much = time consuming) -- what is the output like? image from Arup Lighting www.buildingenergysoftwaretools.com/software-listing Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 19 Physical Models (Analog) as good as the model maker s skills what you see can be what you ll get Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 20

Daylighting Models TVA Building, Chattanooga model testing showed that atrium louvers would cast too-intense shadows Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 21 Using Daylighting Models ^^ architectural daylight meter ^^ mirror sky what you see (windows behind stage not a good idea) ^^ Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 22

Daylighting Design Tools vs. Shading Design Tools artificial sky (LBL): can simulate clear and overcast skies heliodon (PEC): simulates direct solar radiation Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 23 Several Examples of Daylighting as with the Kimbell Art Museum, a very architectural daylighting fixture is a key building feature Mount Angel Library, Mt. Angel, OR, Alvar Aalto (1970) Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 24

supplemental electric lighting compare size of circular skylight to size of opening on roof (three slides down) Mount Angel Library Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 25 Mount Angel Library Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 26

Mount Angel Library Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 27 note electric lamps over bubble skylights honest / dishonest? note three different shading treatments on one façade; the interior conditions drive this Mount Angel Library Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 28

surfaces adjacent to apertures are designed to spread daylight and reduce contrast Mount Angel Library Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 29 reading carrels receive and pass on daylight; providing for both privacy and daylight transfer Mount Angel Library Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 30

www.usafa.af.mil/ U.S. Air Force Academy Chapel, Colorado Springs, CO, SOM Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 31 U.S. Air Force Academy Chapel Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 32

stained glass as object Churches, Color, and Daylighting, Portland, OR Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 33 stained glass as illuminator Churches, Color, and Daylighting, Eugene, OR Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 34

under daylight under electric light the lighting fixtures >> Churches, Color, and Daylighting, Portland, OR Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 35 daylighting as fallout from a powerful design concept Thorncrown Chapel, Eureka Springs, AR, Fay Jones Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 36

Thorncrown Chapel Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 37 Thorncrown Chapel Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 38

Thorncrown Chapel Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 39 Thorncrown Chapel Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 40

daylighting as a means of expression http://en.wikipedia.org/wiki/mit_chapel MIT Chapel, Cambridge, MA, Eero Saarinen see following slide for results Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 41 daylighting (and electric lighting) as expression a hard-to-photograph detail where daylighting provides uplight a daylit sculpture highlighting texture MIT Chapel Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 42

sunlighting/daylighting as connection circulation spine, earth sheltered bookstore, University of Minnesota unless blinding, direct solar is often welcomed below ground Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 43