Product Description. Options. Fan Voltage. Electrical Connections Technical Data - Key Characteristics

Similar documents
ClimaSys Resistance heaters Selection guide

electronics Protection

Resistance heaters. Ventilation systems. Air-air exchangers. Air-water exchangers. Cooling units. Control devices. Calculation and selection

Performance Data. Accessories Enclosure Heaters. curus Component Recognized; File No. E IP 20 CE

Thermal management for your cabinets!

Enclosure Heaters and Fan Heaters

Application. Specifications. Finish

Performance Data. curus Component Recognized; File No. E IP 20

TOUCH-SAFE HEATERS INDUSTRY STANDARDS

SELECTION GUIDE. Industrial Thermoregulation. Products for panels and enclosures

CR 027 PTC Fan Heater W

Anti Condensation Heaters

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE

Hazardous Area Portable Fan Heater The Bulldog

Stego accessories for cabinets

Content. Heating. Ventilating. Regulating and Monitoring. Lighting. Accessories

Thermal Management Products & Accessories for Enclosures

VIII. Heaters Mobile Climate Control 121 MCC Reference Manual 2014

Hazardous Area Portable Fan Heater The Bulldog

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Positive Temperature Coefficient (PTC2) Heater Manual

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE

The Inceptor Lighting Range is perfect for all types of installation...

stego_katalog_2008_en.qxp:englisch :09 Uhr Seite 1 Product Catalogue

Condensing Units CUS 15-60

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

RIVERA P5000. Folding awning P5000

Hazardous Area Portable Fan Heater The Bulldog

EFBW series - BiWire Ultra control panel

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

Refrigeration and Air Conditioning Technical leaflet. Electronic controller EKC 201 and EKC 301

The ideal cooler at a competitive price KELVION TEC COMMERCIAL AIR COOLER

The new WAREMA external venetian blind 80 S PROVEN THINGS IN PERFECTION

Heaters, Thermostats and Hygrostats

Scha tschra Hei u g E c sure heater R sista ces chauffa tes Scha e astverwar i ge. Risca dat re a tic de sa Resiste cia ca efact ra 3105 XXX

Life insurance for your electronics

Element: Stainless steel (encapsulated) resistance wire. Fresh-Air-Fan 2 capacities. Standing model IP24

5 Litex Elite. Industrial. Up to 170Llm/cW. Mains lighting IK10

Industrial Signalling. Signalling Solutions

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Sinus Jevi (Explosion-Proof) Condens Heaters

VEROTEC Electronics Packaging

Cooling unit Mechanical control

standards: standards:

GV Standard X-Vent Operation and Maintenance Manual

CoreLine Panel the clear choice for LED

LINETRAXX VMD420. Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry

HEATING. Anticondensation Heaters

Dual Pressure Controls

DCS-100. intelligent damper control & monitoring system

Frequently Asked Questions- Kapton and Silicone Rubber Heaters Kapton (Polyimide) and Silicone Flexible Heaters FAQ s

Main technical datas:

Ledinaire Batten Simply great LED

ISIS SAFETY SYSTEM Installation guide

Extreme industrial environments Air/water heat exchangers (roof-mounted, wall-mounted) Recooling system

Off-Grid CyboInverter Installation Guide. For CI-Mini-1200H Solar Mini-Inverter for Electric Water Heaters

UV Flame Supervision System

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

Motogard. Over Temperature Protection System. Installation Instructions

THERMASREG TR 040 THERMASREG TR 060

FAST RESPONSE TEMPERATURE SENSORS 42.11a

Helios. Unit Heater. Thickness 1 mm. Diameter 22 mm. Pitch 2,5 mm. Fin 0,12 mm

Fire protection in tunnels and public buildings

Heating THERMAL MANAGEMENT SOLUTIONS FOR ELECTRICAL ENCLOSURES

Homepage > Products > Decentralised ventilation Systems > Vertical devices > Type FSL-V-ZUS. Type FSL-V-ZUS

Industrial Signalling

The insurance for your regulation!

Rittal roof-mounted fans Efficiency on top

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE

MSM - Expansion modules

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

CF1 ProVector Explosion-Proof Heaters

Advantages / Characteristics

Level gauges Series LS Level indicator, switch and transmitter for liquids

Sun Ray Electric Radiators Stylish, Efficient, Low Energy

Eldon Product Overview

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

RAYPAK HOT WATER & HEATING

INSTRUCTION MANUAL A131 High Level Audible Warning System

Optimal work climate with open doors. Industrial air curtains Model IndAC

RAYPAK HOT WATER & HEATING

Rittal roof-mounted fans

CMD420 / CMD421 Series

Product Management, Rev 3 December 2009

INSTRUCTION & SERVICE MANUAL

Gas cylinder scale Model GCS-1

THERMAL MANAGEMENT THERMAL MANAGEMENT. Accessories: GV 400/500 or GV 600/700 AM 420P TRS 60, TRW 60, TWR 60, TKW 60 FILTER FANS SERIES LV

Dräger Polytron 5700 IR Detection of flammable gases and vapours

ALL THE BENEFITS OF THE ALL COPPER HEAT EXCHANGER

VA G 052 S

Outdoor Enclosures. Outdoor Enclosures Protected like a bunker for all harsh environments

ROOFTOP PACKAGED AIR CONDITIONERS

Proximity Sensors Capacitive Thermoplastic Polyester Housing Types CA18CAN/CAF...

Maxos LED General Lighting innovative, flexible solution delivers ideal light output

Interface Modules for SENTRI

INTRAD WALL PROTECTION SYSTEMS

Safety Rope Pull Switches SRM, SR. General information on safety rope pull switches

Safe Enclosure Cooling

Transcription:

Cirrus 25/1 The Cirrus 25/1 range of fan heaters uses PTC ceramic heating technology to provide the user with a product ideally suited to climate control. The heater can be controlled independently to the fan, allowing a fan-only mode for air circulation. There are nine variants, giving different power and supply voltage capability. The product has been designed, and approved, for build-in applications. It has a robust construction utilising two anodised aluminium extrusions, coupled to a 25mm fan. The heating element is a DBK PTC heater. For ease of installation the product can be supplied with a factory fitted 35mm DIN-rail mounting clip, and electrical connection is via colour coded stripped-end wires. To enable the use of different supply voltages to the fan nominal, Smartcan is employed within the harness on certain units. DBK Part No Power Output (@ 10ºC) Heater Voltage Fan Voltage FGC 0002.2R 5W 12V AC/DC 12V DC FGC 0004.2R 10W 12V AC/DC 12V DC FGC 0005.2R 20W 12V AC/DC 12V DC FGC 0011.2R 5W 12V AC/DC 12V AC* FGC 0013.2R 10W 12V AC/DC 12V AC* FGC 0014.2R 20W 12V AC/DC 12V AC* FGC 0015.2R 5W 24V AC/DC 24V AC/DC* FGC 0017.2R 10W 24V AC/DC 24V AC/DC* FGC 0018.2R 20W 24V AC/DC 24V AC/DC* * Use Smartcan FGF 01 25mm wire finger guard Factory fitted at outlet only Nominal Power @ 10º C 5W 10W 20W Typical max in-rush current (A) RMS @ 12V AC Typical max in-rush current (A) RMS @ 24V AC 0.5 1.5 3 1.3 1.3 3 5.1 5.1 5.1 Fan life time - L10 @ 40ºC(Hrs) 120,000 120,000 120,000 Fan Operating temperature range (ºC) -10 to +70-10 to +70-10 to +70 Nominal input voltage Dimensions (mm) - cross section 26x27 26x27 26x27 Length (mm) 50 50 50 Weight (g) 60 60 60 Finger guards at outlet Optional Optional Optional

Cirrus 25/2 The Cirrus 25/2 range of fan heaters uses PTC ceramic heating technology to provide the user with a product ideally suited to climate control. The heater can be controlled independently to the fan, allowing a fan-only mode for air circulation. There are eighteen variants, giving different power and supply voltage capability. The product has been designed, and approved, for build-in applications. It has a robust construction utilising two anodised aluminium extrusions, coupled to a 25mm fan. The heating element is a DBK PTC heater. For ease of installation the product can be supplied with a factory fitted 35mm DIN-rail mounting clip, and electrical connection is via colour coded stripped-end wires. To enable the use of different supply voltages to the fan nominal, Smartcan is employed within the harness on certain units. DBK Part No Power Output (@ 10ºC) Heater Voltage Fan Voltage FGC 0501.2R 20W 12V AC/DC 12V DC FGC 0502.2R 30W 12V AC/DC 12V DC FGC 0503.2R 40W 12V AC/DC 12V DC FGC 0504.2R 20W 115/ 12V DC FGC 0505.2R 30W 115/ 12V DC FGC 0506.2R 40W 115/ 12V DC FGC 0515.2R 20W 12V AC/DC 12V AC* FGC 0516.2R 30W 12V AC/DC 12V AC* FGC 0517.2R 40W 12V AC/DC 12V AC* FGC 0518.2R 20W 115/ 12V AC* FGC 0519.2R 30W 115/ 12V AC* FGC 0520.2R 40W 115/ 12V AC* FGC 0521.2R 10W 24V AC/DC 24V AC/DC* FGC 0523.2R 30W 24V AC/DC 24V AC/DC* FGC 0524.2R 40W 24V AC/DC 24V AC/DC* FGC 0525.2R 20W 115/ 24V AC/DC* FGC 0526.2R 30W 115/ 24V AC/DC* FGC 0527.2R 40W 115/ 24V AC/DC* * Use Smartcan FGF 01 25mm wire finger guard Factory fitted at outlet only Nominal Power @ 10º C 10W 20W 30W 40W - 2.5 4 5 @ 12V AC 2.5-5.5 9.5 @ 24V AC @ - 0.5/2.5 1/3.5 1/3.5 115/ 5.1 5.1 5.1 5.1 Fan life time - L10 @ 40ºC(Hrs) 120,000 120,000 120,000 120,000 Fan Operating temperature range (ºC) -10 to +70-10 to +70-10 to +70-10 to +70 Nominal input voltage (Fan) Nominal input voltage (Heater) 12AC/DC or 12AC/DC or 12AC/DC or 24AC/ 115/230 or 115/230 DC or 115/230 Dimensions (mm) - cross section 26x27 26x27 26x27 26x27 Length (mm) 72 72 72 72 Weight (g) 90 90 90 90 Finger guards at outlet (High Voltage N/A Yes Yes Yes Finger guards at outlet (Low Voltage Optional Optional Optional Optional

Cirrus 40/1 DBK Part No Power Output (@ 10ºC) Heater Voltage Fan Voltage FGC 1032.2R 50W 12V AC/DC 12V DC FGC 1002.2R 60W 12V AC/DC 12V DC FGC 1035.2R 50W 115/ 12V DC FGC 1005.2R 60W 115/ 12V DC FGC 1006.2R 80W 115/ 12V DC FGC 1007.2R 100W 115/ 12V DC FGC 1033.2R 50W 12V AC/DC 12V AC* FGC 1018.2R 60W 12V AC/DC 12V AC* FGC 1036.2R 50W 115/ 12V AC* FGC 1021.2R 60W 115/ 12V AC* FGC 1022.2R 80W 115/ 12V AC* FGC 1023.2R 100W 115/ 12V AC* FGC 1034.2R 50W 24V AC/DC 24V AC/DC* FGC 1026.2R 60W 24V AC/DC 24V AC/DC* FGC 1037.2R 50W 115/ 24V AC/DC* FGC 1029.2R 60W 115/ 24V AC/DC* FGC 1030.2R 80W 115/ 24V AC/DC* FGC 1031.2R 100W 115/ 24V AC/DC* * Use Smartcan FGF 01 40mm wire finger guard Factory fitted at outlet only. Optional at inlet. FGF 08 Plastic 40mm finger guard Optional FGF 05 Plastic 40mm finger guard and filter assembly Optional The Cirrus 40/1 range of fan heaters uses PTC ceramic heating technology to provide the user with a product ideally suited to climate control. The heater can be controlled independently to the fan, allowing a fan-only mode for air circulation. There are eighteen variants, giving different power and supply voltage capability. The product has been designed, and approved, for build-in applications. It has a robust construction utilising two anodised aluminium extrusions, coupled to a 40mm fan. The heating element is a DBK PTC heater. For ease of installation the product can be supplied with a factory fitted 35mm DIN-rail mounting clip, and electrical connection is via colour coded stripped-end wires. To enable the use of different supply voltages to the fan nominal, Smartcan is employed within the harness on certain units. Nominal Power @ 10º C 50W 60W 80W 100W @ 12V AC @ 24V AC @ 115/ 5 6.5 - - 5.5 7.5 - - 2/6 1.5/5 2/6.5 1.5/4.5 13.6 13.6 13.6 13.6 Fan life time - L10 @ 40ºC(Hrs) 120,000 120,000 120,000 120,000 Fan Operating temperature range (ºC) Nominal input voltage (Fan) Nominal input voltage (Heater) -10 to +70-10 to +70-10 to +70-10 to +70 12AC/DC or 24AC/ DC or 115/230 12AC/DC or 24AC/ DC or 115/230 115/230 115/230 Dimensions (mm) - cross section 42x42 42x42 42x42 42x42 Length (mm) 72/77 72/77 77 77 Weight (g) 175 175 175 175 Finger guards at outlet (High Voltage Yes Yes Yes Yes Finger guards at outlet (Low Voltage Optional Optional N/A N/A

Cirrus 40/2 DBK Part No Power Output (@ 10ºC) Heater Voltage Fan Voltage FGC 1500.2R 125W 115/ 12V DC FGC 1501.2R 150W 115/ 12V DC FGC 1502.2R 200W 115/ 12V DC FGC 1503.2R 230W 115/ 12V DC FGC 1507.2R 230W 115/ 24V DC FGC 1508.2R 125W 115/ 12V AC* FGC 1509.2R 150W 115/ 12V AC* FGC 1510.2R 200W 115/ 12V AC* FGC 1511.2R 230W 115/ 12V AC* FGC 1512.2R 125W 115/ 24V AC/DC* FGC 1513.2R 150W 115/ 24V AC/DC* FGC 1514.2R 200W 115/ 24V AC/DC* FGC 1515.2R 230W 115/ 24V AC/DC* FGC 1580.2R 275W 115/ 12V DC FGC 1581.2R 275W 115/ 12V AC* FGC 1582.2R 275W 115/ 24V DC FGC 1583.2R 275W 115/ 24V AC/DC* * Use Smartcan The Cirrus 40/2 range of fan heaters uses PTC ceramic heating technology to provide the user with a product ideally suited to climate control. The heater can be controlled independently to the fan, allowing a fan-only mode for air circulation. There are seventeen variants, giving different power and supply voltage capability. The product has been designed, and approved, for build-in applications. It has a robust construction utilising two anodised aluminium extrusions, coupled to a 40mm fan. The heating element is a DBK PTC heater. For ease of installation the product can be supplied with a factory fitted 35mm DIN-rail mounting clip, and electrical connection is via colour coded stripped-end wires. To enable the use of different supply voltages to the fan nominal, Smartcan is employed within the harness on certain units. FGF 01 40mm wire finger guard Factory fitted at outlet only. Optional at inlet. FGF 08 Plastic 40mm finger guard Optional FGF 05 Plastic 40mm finger guard and filter assembly Optional Nominal Power @ 10º C 125W 150W 200W 230W 275W (CE Marked only) Typical max in-rush current (A) 10 10 9 9 11 RMS @ 12.4 12.4 12.4 17 17 Fan life time - L10 @ 40ºC(Hrs) 120,000 120,000 120,000 50,000 50,000 Fan Operating temperature -10 to +70-10 to +70-10 to +70-20 to +60-20 to +60 range (ºC) Nominal input voltage (Fan) 12DC, 12AC or 12DC, 12AC or Nominal input voltage (Heater) 115/230 115/230 115/230 115/230 115/230 Dimensions (mm) - cross 42x42 42x42 42x42 42x42 42x42 section Length (mm) 112 112 112 122 122 Weight (g) 260 260 260 275 275 Finger guards at outlet Yes Yes Yes Yes Yes

Cirrus 60 The Cirrus 60 range of fan heaters comprises forced air enclosure heaters that use PTC ceramic heating technology. They can also be used in a fan-only mode (no heat) providing the user flexibility of use applications. There are two primary variants, giving different power and supply voltage capability. are capable of running both heater and fan from mains voltage whilst maintaining the high airflow and power performance normally seen only using a DC fan. Each option has a user selectable power output for no heat, 200W, 300W or full power output at 400W. The product has been designed, and approved, for built-in applications. It has a robust construction utilising high temperature plastic mouldings, coupled to a 60mm fan. VDE 40024197 The heating element is a DBK Al finned PTC air heater. For ease of installation the product can be supplied with a factory fitted 35mm DIN-rail mounting clip or either two bracketmount options, and electrical connection via flying leads. DBK Part No Power Output (@ 10ºC) Supply Voltage FGC 3000 400/300/200W Heater & Fan FGC 3001 400/300/200W Heater & Fan FGB 300 35mm DIN clip EN50022 Factory fitted FGB 301 Side mount bracket Factory fitted FGB 302 Bulkhead bracket Factory fitted Nominal Power @ 10º C 400W 300W 200W Typical peak in-rush current (A) RMS 10 8 4 @ Typical peak in-rush current (A) RMS 5 3.5 1.75 @ Maximum body temperature (40ºC 55 50 45 Ambient) Electrical protection class II II II Ingress protection IP20 IP20 IP20 Operating temperature range (ºC) -10 to +70-10 to +70-10 to +70 Storage temperature range (ºC) -40 to +70-40 to +70-40 to +70 at 50Hz (230V 10 10 10 AC) at 60Hz (115V 13 13 13 AC) Fan life time - L10 @ 40ºC(Hrs) 49,000 49,000 49,000 Nominal input voltage (depending on variant) Dimensions (mm) cross section length 71x70 96.5 71x70 96.5 71x70 96.5 Harness length (mm) 240 240 240 Weight (g) - add 35g for bracket 275 275 275 Finger guards at inlet and outlet Yes Yes Yes

Cirrus 80 The Cirrus 80 range of fan heaters comprises forced air enclosure heaters that use PTC ceramic heating technology. They can also be used in a fan-only mode (no heat) providing the user flexibility of use applications. There are four variants, giving different power and supply voltage capability. (Each has a user selectable power output for no heat, half heat or full heat output.) The product has been designed, and approved, for built-in applications. It has a robust construction utilising an anodised aluminium extrusion and a high temperature plastic moulding, coupled to an 80mm fan. VDE 40024201 The heating element is a DBK Al finned PTC air heater. All products in this range have a built-in electrically re-settable safety thermostat to protect the product in the event of fan failure. For ease of installation the product can be supplied with a factory fitted 35mm DIN-rail mounting clip, electrical connection is via an easily accessible connector block. DBK Part No Power Output (@ 10ºC) Supply Voltage FGC 2000 300/600W 115V FGC 2001 450/800W 115V FGC 2002 300/600W 230V FGC 2003 450/800W 230V FGB 100 35mm DIN clip Factory fitted FGF 100 30 PPI Filter assembly Approx 10% power output reduction Nominal Power @ 10º C 300/600W 450/800W Typical max in-rush current (A) @ 10 11 Typical max in-rush current (A) @ 15 14 Maximum at body temperature 55 80 (ºC) Operating temperature range (ºC) -40 to +60-40 to +60 31-35 31-35 Fan life time - L10 @ 40ºC(Hrs) 43.500 43.500 Nominal input voltage V AC 115 or 115 or 230 230 Dimensions (mm) cross section length 82x110 150 82x110 150 Weight (g) 785 785 Finger guards at inlet and outlet Yes Yes