ANALYSIS OF SOLAR THERMAL WATER HEATERS ON PEAK DEMAND

Similar documents
Performance of Solar Water Heating Systems in the United States

INSTRUMENTATION AND EVALUATION OF COMMERCIAL AND HOMEMADE PASSIVE SOLAR PANELS

1 Exam Prep Solar Water and Pool Heating Manual (UCF) Questions and Answers (Plumbing Contractor)

Guide To Troubleshooting INEFFICIENT COOLING FANS

Solar Thermal Planning Worksheet Date: / /

SOLAR HOT WATER HEATERS

Solar Water Heaters. Bastián Acevedo Bustos. Electronic Engineering Student, Tarapacá University. Environmental Studies Student, York University

Solar water heating system

Selecting a New Water Heater

New Construction Builders Challenge: Sealed Attic and High Efficiency HVAC in Central Florida: A Year in Review

OPERATING MANUAL Enertronic Control System 2

WeatherLink for Alarm Output Addendum

VENTILATIVE COOLING CONTROL STRATEGIES APPLIED TO PASSIVE HOUSE IN ORDER TO AVOID INDOOR OVERHEATING

Effect Of Setup Thermostat Schedule On Heat Pump Water Heater Energy Consumption, Coefficient Of Performance And Peak Load

Solar Hot Water Heating Systems

Mechanical System Redesign. Dedicated Outdoor Air System. Design Criteria

U.S. Department of Energy - Energy Efficiency and Renewable Energy

PASSIVE HEAT EXCHANGER ANTI-FOULING FOR SOLAR DHW SYSTEMS

Energy Efficiency Potential of Heat Pump Water Heaters in Commercial Buildings

Kills bills. How Vaillant technologies reduce home heating bills

CodeNotes. Solar Water Heating Systems Based on the 2018 International Solar Energy Provisions (ISEP ) Introduction OFFICIAL

Evaluating Peak Load Shifting Abilities and Regulation Service Potential of a Grid Connected Residential Water Heater

ASHRAE JOURNAL ON REHEAT

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

Measurement of Attic Temperatures and Cooling Energy Use in Vented and Sealed Attics in Las Vegas, Nevada

PERFECT ORIENTATION ZONE 40 E 40 W GOOD GOOD ORIENTATION ZONE ORIENTATION ZONE

AHE S -12 VDC AHE S - 24 VDC

SOLAR WATER DISTILLATION BY USING WATER IN THE INNER GLASS EVACUATED TUBES

Solar Water Heating Basics for Homeowners

Calculated Energy Savings for Disabling Anti- Sweat Door Heat on Glass Display Case Doors

INDIRECT SYSTEM FOR FROST LOCATIONS

Performance Comparison of Hydronic Secondary Loop Heat Pump and Conventional Air-Source Heat Pump ABSTRACT 1. INTRODUCTION

Chilled beam technology overview John Woollett 1, Jonas Åkesson 2 Swegon AB 1,2

Florida Energy Extension Service

Tempco s process controllers provide integrated solutions to manage your thermal loop system.

Multifamily Buildings: Real World Monitored Data on Hot Water Energy and Water Use

STUDY ON SOLAR WATER HEATER AND ITS SYSTEM PERFORMANCE

B-40/B-41 Modulating Temperature Controller

THERMAL ICE STORAGE: Application & Design Guide

CN7232 Advanced Garage Ventilation Controller

Copyright 2003 IBACOS, Inc. All rights reserved.

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

Open and Closed Door Moisture Transport and Corresponding Energy Consumption in Household Refrigerator

PRESSURE INDEPENDENT CONTROL VALVE TECHNOLOGY. 3/16/2012 Fred Ferrara 1

ProgressivTube PASSIVE SOLAR WATER HEATERS HOT OUT

RIGID DC LIQUID CHILLER

EZ Plate Instantaneous

SOLAR THERMAL HEATING: ALIVE AND WELL

Orange Solar Pump HD50

Heat Your Water with the Sun

Homework 5: Theory of Operation and Hardware Design Narrative

Ambient (ºF) Temperature Rise Above

Frequently asked questions: Intelligent Transmitter Series

A Technical Introduction to Cool Thermal Energy Storage Commercial Applications

Bosch. Gas Condensing Boiler. Applications Manual. 100, 151 Combi Boiler 57, 100, 131, 151 Heating Boiler

Demonstration of 2nd Generation Ducted GE "Brillion" Hybrid Water Heater in the PNNL Lab Homes

Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water

Testing a capacitive humidity sensor

INSTALLATION INSTRUCTIONS

Heating and D.h.w. Controller RVL482 Basic Documentation

Alternate Energy Technologies, LLC PO Box Jacksonville, FL INSTALLATION OPERATION MAINTENANCE MANUAL THERMOSIPHON FREE-FLOW

GENSET ENGINE HEATING IN A DATA CENTER ENVIRONMENT

Submitted to. Texas A&M University-Corpus Christi The Texas A&M University System. Submitted by. Yeqiao Zhu Dan Turner David Claridge

Energy Efficient Homes: Laundry Area 1

Appendix A Equipment Used to Monitor Hotels

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Falling Film Heat Exchangers for Solar Water Heaters

SEISCO APPLICATIONS & DIAGRAMS

CodeNotes. Solar Water Heating Systems Based on the 2015 International Solar Energy Provisions. Introduction. Solar Water Heating System Designs

25 per cent of energy used in the home is used to heat water.

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

Head Pressure Control Application Guide

Hydronic & HVAC Control Systems

Solar & Hydronic Heating

TRACENET TM TN SERIES

BEST-IN-CLASS PERFORMANCE 2015 Q3 SAME-STORE

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

HOBO U30 Remote Monitoring Systems

Laboratory Evaluation of Hybrid and Advanced Water Heaters: Performance Overview in Hot Humid Climate

TECHNOLOGY GUIDE. :: the dawn of a new era in commercial HVAC technology. The all-new Rheem Commercial Renaissance Line featuring:

Isotemp. Improve the productivity of your laboratory with accurate, efficient temperature control products from Fisher Scientific.

Substation Monitoring System

User reference guide. Daikin Altherma Low temperature split EHBH04CB EHBH08CB EHBH11CB EHBH16CB EHBX04CB EHBX08CB EHBX11CB EHBX16CB

SURVEY ON THE OCCUPANT BEHAVIOR RELATING TO WINDOW AND AIR CONDITIONER OPERATION IN THE RESIDENTIAL BUILDINGS

OPERATING MANUAL Enertronic Control System 2

Storing excess daytime solar energy to heat greenhouse at night!

Hot Food Holding Cabinets Test for FWE HLC

Substation Monitoring System

Open Source Home Security System

Air & Water Heat Pump R832

Flair 500 Series Annunciators

SOLAR HOT WATER AND HEAT PUMP BOOSTER ENERGY CALCULATION METHODOLOGY

H o t Wa te r Syste m s. Senator Electric Flow Boilers. Making Life Simpler

Dehumidification: Energy Efficiency Comparisons

Solar Matters III Teacher Page

Mechanical Heat Pump R515

BUILDING MANAGEMENT SYSTEMS. Introduction to Building Management Systems

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

Computer Modelling and Simulation of a Smart Water Heater

Transcription:

Proceedings of ECTC 2008 2008 ASME Early Career Technical Conference October 3-4, 2008, Miami, Florida, USA ANALYSIS OF SOLAR THERMAL WATER HEATERS ON PEAK DEMAND Benjamin S. Swanson University of Florida Gainesville, Florida, USA James H. Fletcher University of North Florida Jacksonville, Florida, USA William Lear University of Florida Gainesville, Florida, USA Author Name Affiliation City, State, Country Author name Affiliation City, State, Country ABSTRACT The University of North Florida (UNF) has a long term working partnership with the local utility company, JEA. As a winter peaking utility JEA and UNF are investigating the effects of solar thermal water heaters on peak demand. This investigation includes household usage studies, a solar water heater performance comparison study and their thermal capacitance, and a software model to predict system performance. In this paper, initial household usage and incentivized popular solar thermal systems are studied and incorporated into a solar thermal direct comparison test rig. INTRODUCTION JEA and UNF are long term partners in building the UNF Clean and Renewable Energy lab. The focus of the partnership and lab is to educate students and explore alternative approaches to meeting the greater Jacksonville area s utility needs. JEA currently is a winter peaking utility, with a large percentage of Jacksonville s population using the most residential power on weekdays between 6am and 10am in the morning and 6pm to 10pm in the evening [1]. Domestic water heating can account for as much as 21% of residential electrical consumption [2]. Residential solar water heating systems have been in use since the late 1800s and presently have the potential of displacing the electricity used in domestic water heating [3]. In an effort to reduce and offset the winter peaks, JEA and UNF are partnering to study the effects of Solar Thermal Water Heating Systems on Peak Demand. HOUSEHOLD USAGE AND SYSTEM SIZING Studies show that residential hot water usage correlates with electrical peak times. Usage trends, as seen on Figure 1, suggest that 29% of hot water usage is between 6am and 10am and 31% is between 6pm and 10pm [4]. JEA s energy demand peaks could be greatly reduced and/or offset through an effective solar water heating system. Figure 1. Histogram of identified hourly hot water draw profiles To best study the effects of solar thermal water heating systems on peak demand, two popular incentivized systems are incorporated into a test rig. The Department of Energy suggests sizing each system s collector area as 20 square feet for each of the first two family members and 1.5 to 2 gallons of storage per square feet of collector [5]. Based on these guidelines the particular systems included in the study are: one Integral Collector Storage (ICS) passive unit with 32 square feet of solar collection area and 40 gallons of storage, and an Active Drain-Back Solar Technology System with an 80 gallon remote storage tank, 10 gallon drain-back heat exchanger tank, and 32 square feet of collector surface area. Based on the average home of 2.8 occupants with the most common being two and the approximate suggested sizing of 20 square feet per 1.1

occupant, the systems installed each provide a base for a larger than half scale experiment [6]. Figure 2. ICS Passive System The ICS system, shown on Figure 2, is a simple system not requiring any controls or moving parts. The system provides 40 gallons of additional storage and preheats the water entering the conventional electrical resistance domestic water heater. A major concern with this type of system is the potential to freeze in harsh winter environments. In comparison, the Active Drain-Back Solar Technology System, shown on Figure 3, is more complex. The system incorporates a temperature controlled closed heating loop that circulates water from the heat exchanger through the collector. The system also has an open loop that circulates water from a storage tank through the heat exchanger. The controls strategy compares the temperature of the bottom of the storage tank with the exit temperature of the collector and engages pumps to move water according to the control logic. If the collector cannot provide additional heat to the storage tank it will drain back into the heat exchanger; protecting the active system from freezes. Figure 3. Active Drain-Back System TEST RIG SUPPORT STRUCTURE The test rig is currently installed on the top of the UNF Science and Engineering Building facing south. South facing orientation provides optimal solar collection in any location in the Northern Hemisphere. For year round performance the recommended tilt for the collectors is equal to the latitude. For increased winter performance and to protect from overheating in the summers many installers increase the angle up to 20 degrees greater than the latitude [7]. Conventional roof slopes range from a 4:12 to a 9:12, which corresponds to approximately an 18 to 37 degree range [8]. Due to ease of installation and aesthetics many collectors are installed directly on to the roof of houses and experience minimal loss in performance. The latitude in Jacksonville is 30.3 degrees, which directly corresponds to a 7:12 roof pitch. Initial testing for these systems is with a latitude +10 degree tilt for improved winter performance. The flexibility for varying tilt angles for future testing has been incorporated into the design of construction. Access to the roof of the UNF Science and Engineering Building is provided by an elevator. Consequently, much of the construction had to take place on the roof, adding a design restraint. An additional design restraint is making the unit hurricane ready without altering the roof or building in any way. The decided best short term approach to this hurdle is to use modular construction allowing for break down in a short time period and relocation of the modules into a near by room through a door with a width of 42 inches. A long term solution is being incorporated into another solar project on the roof and will provide a hurricane approved steel structure. The support structure, for the time being, includes a multilevel platform constructed of two by six inch pine lumber and half inch plywood. Multilevel construction provides the panels a sturdy mounting structure and prevents one panel from shading the other as seen on Figure 4. The structure also provides a protected location for support systems and components. It is recommended that the Active panel be mounted portrait and the Passive panel be mounted landscape. After study and discussions with suppliers and installers, it was determined that mounting both panels landscape would not affect performance, but was a potential freeze hazard as the active panel could retain a small amount of water even after drain-back. The storage tank for the active system is located in an adjacent storage room and plumbed in through access ports in the wall. This was decided as the storage space best replicates a garage environment similar to that of a typical domestic water heater. 1.2

Figure 4. Multilevel Structure consumed hot water during each morning peak, lull between peaks, and evening peak for each system. Based on this information the subsystem will need to provide 51 +/- 7 degree Fahrenheit water at a flow rate of approximately 2.3 gallons per hour (gph) during peak periods and 1.15 gph in between the morning and afternoon peaks for each system. To control the variables and minimize water waste a closed loop subsystem was constructed. This subsystem consists of a shallow well pump, a solenoid valve controlled by a timer switch, ball valves for throttling, two 94 gallon tanks, a temperature controlled secondary pump running water through a radiator loop, and a temperature controlled immersion heater. A simple layout is shown on Figure 6. GROUNDWATER AND USER SUBSYSTEM A critical component to the experiment is a subsystem for replicating groundwater temperature and pressure for input, and approximate residential hot water consumption. As there is no fresh water supply on the roof; water conservation is important. Groundwater temperature varies from the mid forties to the upper sixties throughout the year. Because the main focus of the study pertains to winter peaks, groundwater temperatures during the months November to March are most critical. Figure 5 shows this to range from approximately 44 degrees to 58 degrees Fahrenheit [9]. Temperatures during this time frame in Jacksonville range from approximately 42 to 51 degrees Fahrenheit for the lows and 64 to 73 degrees for the highs [10]. City water pressure varies from 40 to 60psi. Figure 5. Average Monthly Cold Water Inlet Temperature for Each Home Figure 6. Subsystem Layout The primary pump for replicating groundwater conditions is a shallow well pump with a pressure switch. Using a pressure switch the pump can be set to shut off when proper designated pressure is reached and the system can be timer controlled with a solenoid valve. This timer and valve can turn on at various times to replicate peaks and will respond very similar to a family opening a valve to turn on the shower. A ball valve is installed on each system to throttle the flow to an established setting. Storage is provided by two 30 by 30 by 26 inch polyethylene tanks. The tanks provide approximately 94 gallons of storage each, presented on Figure 7. The primary pump draws from one tank and the solenoid valve returns to the other. The tanks are connected to provide water level equalization as well as a quiescent reservoir. Household loading includes water temperature, flow rates, time of day, and consumption. Household hot water consumption averages between 45 and 66 gallons a day depending on time of year. Based on the distribution of hot water usage throughout the day, the average hot water consumption, and the reduction as a factor of scale, the load profile can be broken down as 7.5 to 11 gallons of 1.3

The temperature control loop is made up of a secondary pump, a radiator with fans, an immersion heater, and a custom made relay network controlled by the data acquisition system. Sizing the secondary pump and radiator system involved a thorough analysis to effectively rid the water of the heat created by the solar thermal systems. Due to the nature of the closed loop system it is critical that the water temperature return to groundwater temperature before returning to the inlet of the systems. One of the design parameters is the system must run off 115 Volts Alternating Current (VAC). This parameter is important in that many of the portable chiller units require 230VAC and would not be applicable. Using the First Law of Thermodynamics heat removal can be calculated. Q = H H = m x h Figure 7. Subsystem Water Storage Using these equations and some estimated extremes, a radiator with 10,900 British Thermal Units per hour (BTU/hr) heat removal was put into place with two fans moving 550 cubic feet per minute (cfm) each and a pump moving approximately two gallons per minute are incorporated into the cooling loop. The radiator and fans are shown on Figure 8. An immersion heater is also incorporated into the subsystem for the rare days when tank water temperatures drop unreasonably low. Both the radiator loop and the immersion heater are reasonably oversized in the event that any unexpected extreme temperatures are encountered and controlled using a custom temperature controlled relay network. The Data Acquisition system has programmable control outputs. The outputs are small Direct Current (DC) voltages and are not strong enough to close the power relays. A custom amplifier was built to take the small DC voltage and provide adequate power to close the relays. The amplifier is essentially an additional set of small relays that use the control signals to power a switch completing the circuit between an AC power supply and the power relays. The amplifier is made up of an AC power supply, an AC to DC rectifier, a couple of diodes, transistors and resistors. The components are shown on Figure 9. This system allows temperature set points declared in the data logger to control the secondary pump and fans of the cooling loop and also the immersion heater. These set points can be programmed to replicate ground water conditions. Figure 9. Power Supply, Power Relays, and Custom Amplifier Circuit The Data Acquisition system, shown on Figure 10, consists of a Data Logger with 20 analog differential channels. The unit collects temperature data from six T- Type Thermocouples. These include: ambient, tank, and each system s inlet and outlet temperatures. A pyranometer collects solar radiation data for referencing. Positive displacement flow meters are installed and provide a pulse for recording flow rates. Data is sampled every second and recorded every fifteen minutes. The Data Logger and custom control network are enclosed in a NEMA cabinet for protection from the elements. A flash memory card is installed in the Data Logger for easy data retrieval and the unit also has a serial cable with USB interface for program updates and data retrieval. Figure 8. Radiator with Fans 1.4

Figure 10. Data Acquisition REFERENCES [1] Owens, K.. "Request for Letters of Interest." Renewable Energy Generation. 22 March 2007. JEA. 20 Jul 2008 <http://www.eere.energy.gov/greenpower/financial/pdfs/0 307_jea.pdf>. [2] Merrigan, T. and Parker, D. "Electrical Use, Efficiency, and Peak Demand of Electric Resistance, Heat Pump, Desuperheater, and Solar Hot Water Systems." American Council for an Energy Efficient Economy, August 1990, Asilomar Conference Center, Pacific Grove, CA FSEC-PF-215-90(1990) 1-2. 31 Jul 2008 <http://www.fsec.ucf.edu/en/publications/html/fsec-pf- 215-90/index.htm>. [3] Perlin, John. "Solar Thermal." SOLAR EVOLUTION The History of Solar Energy. (2005). California Solar Center. 31 Jul 2008 <http://www.californiasolarcenter.org/history_solartherma l.html>. [4] Fairey, P, and Parker, D. "A Review of Hot Water Draw Profiles Used in Performance Analysis of residential Domestic Hot Water Systems." FSEC-RR-56-04.20 July 2004 5. 31 Jul 2008 <http://www.fsec.ucf.edu/en/publications/pdf/fsec-rr- 56-04.pdf>. [5] "Sizing a Solar Water Heating System." A Consumer's Guide to Energy Efficiency and Renewable Energy. 12 September 2005. U.S. Department of Energy - Energy Efficiency and Renewable Energy. 25 Jul 2008 <http://www.eere.energy.gov/consumer/your_home/water _heating/index.cfm/mytopic=12880?print>. [6] Masiello, J., and Parker, D. " The Symposium on Improving Building Systems in Hot and Humid Climates, San Antonio, TX, May 15-17, 2000.." The Symposium on Improving Building Systems in Hot and Humid Climates FSEC-CR-1671-00 (2000): 2. [7] "Solar Hot Water System Sizing- Collector Tilt." SunMaxxSolar. Solar Energy Powerhouse company, Silicon Solar Inc. 25 Jul 2008 <http://solarhotwater.siliconsolar.com/solar-collectortilt.php>. [8] "Roof Slope." Buyer's Choice Home Inspection. 2008. 25 Jul 2008 <http://www.buyerschoiceinspections.com/roof-slope>. [9] Wiehagen, J., and Sikora, J.L. "DOMESTIC HOT WATER SYSTEM MODELING FOR THE DESIGN OF ENERGY EFFICIENT SYSTEMS." ToolBase Services, c/o NAHB Research Center. April 2002. NREL. 20Jul 2008 <http://www.toolbase.org/design-construction- Guides/Plumbing/domestic-hot-water-system-modeling>. [10] " Climate for Jacksonville, Florida." rssweather.com your local weather feed. 2007. HAMweather. 25 Jul 2008 <http://www.rssweather.com/climate/florida/jacksonville/ >. 1.5