New Size Available Menu SL 10-85G3 Express Setup Load Status Supply Supply User Setup Installer Setup Diagnostics Back IBC 5:59 Return Return A Better Boiler Just Got Better Better Boilers
High Performance Domestic Hot Water Series Indirect Fired Water Heaters Sizes: 30, 40, 55, 65, 80MAX, 119 MAX, 85 XHO, 115XHO (USG) UP TO Hot THAN CONVENTIONAL GAS OR ELECTRIC WATER HEATERS Cold Domestic Water Features High performance domestic hot water. Constructed of 444 grade stainless steel, pickled & passivated for the highest possible resistance to corrosion. High capacity smooth wall stainless steel coil. Maintenance free, light weight design for easy installation. 2 of polystyrene foam insulation for an extremely low standby heat loss. Removable inspection port for easy access to coil and tank. Standard Aquastat & 10KΩ temperature sensor. 10 year non-prorated residential warranty with limited lifetime option. 4011083 Conforms to ANSI Std. 372 4011083 Conforms to the A.G.A. Requirement for Indirect Water Heaters for use with External Heat Source, No. 1-91. MODEL MAX. FIRST HOUR RATING US GAL/Hr @ 135F Based on 180 F boiler supply & 58 F entering cold water CONTINUOUS RATING US GAL/HR@ 135F BOILER OUTPUT REQUIRED BTU/HR BTI 30 159 137 88,000 BTI 40 188 156 100,000 BTI 55 200 156 100,000 BTI 65 325 269 172,000 BTI 80-MAX 453 393 251,000 BTI 119-MAX 545 449 288,000 XHO models have top DHW connections MAX. FIRST HOUR RATING US GAL/Hr @ CONTINOUS RATING US GAL/HR@ MODEL 140F 115F 140F 115F Based on 200 F boiler supply & 50 F entering cold water BOILER OUTPUT REQUIRED BTU/HR 85 XHO 738 992 660 914 495,000 115XHO 763 1017 660 914 495,000 Based on 180 F boiler supply & 50 F entering cold water 85 XHO 641 862 570 790 428,000 115XHO 673 893 570 790 428,000
SL 10-85G3 10,600 to 85,000 BTU/H SL 30-199G3 32,000 to199,000 BTU/H SL 14-115G3 14,000 to 115,000 BTU/H SL 26-260G3 26,000 to 260,000 BTU/H SL 20-160G3 20,000 to 160,000 BTU/H SL 40-399G3 40,000 to 399,000 BTU/H Easy to Use Boiler Control Express setup - program your boiler in seconds. Remote monitoring & diagnostics. Easy USB programmability. Intuitive alert system with detailed error messages. Visible flame current data for troubleshooting. Simplified load pairing. Optional true native BACnet. Easy to Install & Service With supply and return connection on both sides of 4 models, your boiler installation can t get any easier. PVC/CPVC/PPs approved. Longest combined vent lengths Up to 200 ft in 2 and 480 ft in 3 More common parts. With only 2 fans and a universal controller servicing all models just got a lot easier. Fuel conversion kits included in the 4 smaller models. More Built-in Features Built-in zone pump control - up to 4 zones. Replacing the need for external pump controls. Technology: Patented moisture management system. Protects and ensures long life for all components in the boiler. Turndown ratio of up to 10:1 means you have the power to heat your home in the coldest weather, yet reduce short cycling when the weather is mild. Built-in outdoor reset control of water temperature. Built-in CSA/UL approved low water cut-off and manual reset high limit. Reverse flow detection. Unmatched safety features. Connect your IBC Indirect Water Tank directly to the boiler without a primary loop. Better efficiency up to 96% A.F.U.E. (SL 40-399G3 TE/CE 96%). Superior Heat Exchanger The most advanced stainless steel fire tube boiler on the market today. Increased efficiency: Custom baffling to ensure even heat transfer and long life. Commercial Features Multi-boiler communication. Easy boiler network setup. Up to 9.5 million Btu/h (24 boilers) without additional controls. With 24 boilers turndown ratio is 240:1 = min. firing rate range is 40,000 Btu/h all the way up to 9.5 million Btu/h in 1000 Btu/ h increments. Ti option available on SL 40-399G3. DDC Control 0-10 VDC or 4-20 ma without additional controls. Internet capable. Turnkey Multiplex Racking System designed for the SL 399. Complete with all hardware, pumps, valves & fittings. Residential Parts Kit A convenient and cost effective way to maintain and service the 85/115/160/199 residential models. P-350 case contents include: Fan, V-10 Touchscreen Controller, Ignitors, SIM+, Gas Valve, Sensors and Gaskets. Vent kits Flush mount horizontal termination for two pipe PVC systems. P-741 (2 ) P-742 (3 ) Stainless steel horizontal termination for two pipe PVC systems. P-256 (2 ) P-257 (3 ) Floor Stands P-267 Vertical Floor Stand SL 85/115/160/199 Models HC/DC Series P-266 Expandable Floor Stand SL 260/399 Models Convert any SL wall hanging boiler to a floor standing boiler instantly. The expandable floor stand expands and retracts to suit both the 260 and 399 models. All models feature adjustable feet and secure floor bolts. Models Shown: SL 14-115G3 P-267 www.ibcboiler.com
Interior & Technical Information B A B A A) Combustion Air B) Exhaust C) Heat Exchanger D) Ignition Module D E H E) Fan D F) Supply Pipe G) Return Pipe F I E F H) Gas valve I) Supply Temp. Sensor J) Return Temp. Sensor I C K) V-10 Touch Screen L) Air Intake Snorkel M) Tridicator M C L H K J J G G K F G Residential Interior The SL 40-399G3 features an innovative side bolt heat exchanger lid configuration. Commercial / Large Residential Interior SPECIFICATIONS SL 10-85G3 SL 14-115G3 SL 20-160G3 SL 30-199G3 SL 26-260G3 SL 40-399G3 CSA Input (Natural Gas or Propane *) - MBH 10.6-85 14-115 20-160 32-199 26-260 40-399 CSA Input (Natural Gas or Propane *) - KW 3.10-24.9 4.10-33.7 5.86-46.7 9.37-58.3 7.6-76.2 11.7-117 CSA Output - MBH 10.1-79 13.3-109 19.0-147 30-181.3 24.9-239 38.4-383 CSA Output - KW 2.96-23 3.90-32 5.57-43.1 8.8-3.1 7.31-70.0 11.2-112 A.F.U.E. 96% 95% 95% 95% 95% Thermal Efficiency 96% Min gas pressure (NG or Propane) - inch w.c. 4 4 4 4 4 4 Max gas pressure (NG or Propane) - inch w.c. 14 14 14 14 14 14 Ambient temperature - Low ( F/ C) 32 F / 0 C 32 F / 0 C 32 F / 0 C 32 F / 0 C 32 F / 0 C 32 F / 0 C Ambient temperature - High ( F/ C) 122 F / 50 C 122 F / 50 C 122 F / 50 C 122 F / 50 C 122 F / 50 C 122 F / 50 C Max relative humidity (non-condensing) 90% 90% 90% 90% 90% 90% Min water temperature 34 F / 1 C 34 F / 1 C 34 F / 1 C 34 F / 1 C 34 F / 1 C 34 F / 1 C Max programmable water temperature 190 F / 88 C 190 F / 88 C 190 F / 88 C 190 F / 88 C 190 F / 88 C 190 F / 88 C Max ΔT - supply / return (electronic fence) 40 F 40 F 40 F 40 F 40 F 40 F Power use (120Vac/60Hz) - Watts @ full fire - Watt (less pumps) 54 54 73 73 127 190 Weight (empty) - lbs/kg 85 / 39 85 / 39 102 / 46.3 152 / 69 162 / 74 240 / 110 Pressure vessel water content USG/Liters 2.47 / 9.35 2.47 / 9.35 1.72 /6.51 5.09 / 19.3 4.64 / 17.6 6.66 / 25.2 Max boiler flow rate - USgpm 14 14 19 25 25 45 Min boiler flow rate - USgpm 2 2 4 6 6 20 Max operating pressure - psig 30 30 30 30 30 80 Min water pressure - psig 8 8 8 8 8 8 Approved installation altitude - ASL 0-12,000 0-12,000 0-12,000 0-12,000 0-12,000 0-12,000 Maximum equivalent vent length, each side 2 100' 100' 35' (Natural Gas or Propane) 3 240 240 170 150 200 Air intake options: either direct vent or indoor supply 4 200
IBC CONTROL AT YOUR FINGERTIPS All SL Series Boilers come with an IBC V-10 Touch Screen boiler control that is equipped with all of the latest control technology. Easy to setup and monitor with intuitive features like Express Setup, easier Diagnostics & Intuitive Alert System with plain English Warnings & Error Messages, no boiler has ever been easier to use! Express Setup Program your boiler in seconds with an interview style, quick start menu. Pre-programmed values for all load types. User friendly interface for contractor and home owner. Simplified load pairing. Zoning Now featuring multiple zone pump control - up to 4 zones. Replacing the need for external pump controls. Complete Remote Access Built-in internet connectivity. Monitor your boilers operation in real time from your PC/Mac. Easy USB Programmability USB Port for software updates and copying settings to the next boiler. True native BACnet (Optional) Seamlessly integrate IBC BACnet enabled boilers, into your current building automation system. Flexibility - Easy to Service Intuitive alert system with plain English warnings & error messages. Flame current is displayed for troubleshooting. Built-in alarm notification relay. Remote monitoring & diagnostics. Automatic altitude adjustment. A secure method of remotely managing your SL Boiler from any location. MULTI-PLEX RACKING ENGINEERED EASY TO INSTALL TURNKEY SYSTEM A Modular system for commercial and multi family installation the Multiplex racking system components fit through standard doorways reducing the need for heavy transport equipment. Our easy to set up boiler networks also provide for precise load matching through wide turndown ratios. Advanced high grade 439 stainless steel fire tube heat exchanger
Technical Information MAXIMUM EXHAUST VENT LENGTH Exhaust pipe size Maximum equivalent length SL 10-85G3 / SL 14-115G3 SL 20-160G3 SL 30-199G3 SL 26-260G3 SL 40-399G3 Sched.40; Rigid PPs 2 100 35 3 240 170 150 200 4 200 90 Vent elbow allow 8 equivalent allow 8 equivalent allow 8 equivalent allow 8 equivalent allow 8 equivalent 90 Long sweep elbow allow 5 equivalent allow 5 equivalent allow 5 equivalent allow 5 equivalent allow 5 equivalent 45 Elbow allow 3 equivalent allow 3 equivalent allow 3 equivalent allow 3 equivalent allow 3 equivalent PPs 87-90 Elbows use 8 equivalent use 8 equivalent use 8 equivalent use 8 equivalent use 8 equivalent 2 SS Sidewall Terminal (SST) allow 20 equiv. of 2 sched. 40 3 SS Sidewall Terminal (SST) allow 20 equiv. of 3 sched. 40 allow 20 equiv. of 3 sched. 40 allow 20 equiv. of 3 sched. 40 allow 20 equiv. of 3 sched. 40 allow 65 equivalent 3 CPVC (to adapt to the SST) for each 1 allow 3.2 equivalent Flexible PPs 3 Flexible 45 (max.) lineal x 1.2 = equiv. 45 (max.) lineal x 2 = equiv. 30 (max.) lineal x 3.33 = equiv. 60 (max.) lineal x 3.33 = equiv. 4 Flexible 160 max, using 1.2 x for equiv. length CLEARANCE FROM BOILER CABINET Distance from Recommended distance for Surface combustible installation and service surfaces Distance from combustible surfaces Recommended distance for installation and service Distance from combustible surfaces Recommended distance for installation and service SL 10-85G3 / SL 4-115G3 / SL 20-160G3 / SL 30-199G3 SL 26-260G3 SL 40-399G3 Front 2 24 2 24 2 24 Rear 0 0 0 0 0 0 Left side 1 4 (to non-combustibles) 1 0 (to non-combustibles) 1 0 (to non-combustibles) Right side 1 4 (for electric and gas if required) 1 4 (for electric and gas if required) 1 4 (for electric and gas if required) Top 2 6 (for vent connection) 2 6 (for vent connection) 12 12 (for vent connection) Bottom 0 12 (for condensate trap and piping) 0 12 (for condensate trap and piping) 12 12 (for condensate trap and piping) Fuel Conversion Kits: SL 10-85G3 / SL 14-115G3 / SL20-160G3 / SL 30-199G3: Included in the box. SL 26-260G3 NG to LP Part# P-300 / LP to NG Part # P-301 - To be ordered separately SL 40-399G3 NG to LP Part# P-302 / LP to NG Part # P-303 - To be ordered separately Boilers are shipped with 30psi pressure relief valve. H CONNECTIONS SL 10-85G3 / SL 14-115G3 Description SL 20-160G3 SL 30-199G3 SL 26-260G3 SL 40-399G3 Exhaust outlet 3 Schedule 40 3 Schedule 40 3 Schedule 40 4 Schedule 40 Combustion air 3 Schedule 40 3 Schedule 40 3 Schedule 40 4 Schedule 40 Safety relief valve & air vent 3/4 NPT - F 3/4 NPT - F LCD Display 2 1/4 x 4 2-1/4 x 4 2-1/4 x 4 2-1/4 x 4 Water outlet 1 NPT - M 1 1/4 NPT - M 1 1/2 NPT - M 1 1/2 NPT - M Water inlet 1 NPT - M 1 1/4 NPT - M 1 1/2 NPT - M 1 1/2 NPT - M Knock-outs (8) 1/2 1/2 1/2 1/2 Gas inlet 1/2 NPT - F 1/2 NPT - F 3/4 NPT - F 3/4 NPT - F Condensate outlet 3/4 Hose 3/4 Hose 3/4 Hose 3/4 Hose PATENTED MOISTURE MANAGEMENT SYSTEM Protects and ensures long life for all components in the boiler. Burner plate Combustion chamber Flue gas channels Condensate dish oisture ree one Better Boilers IBC Technologies Inc. info@ibcboiler.com www.ibcboiler.com Toll Free: 1-844-HEAT IBC / 1-844-432-8422 British Columbia 8015 North Fraser Way Burnaby, BC V5J 5M8 Tel: 604-877-0277 Fax: 604-877-0295 Ontario Unit 5, 1455 16th Ave., Richmond Hill, ON L4B 4W5 Tel: 905-918-0113 Fax: 604-877-0295 Wisconsin 4507 South Taylor Drive, Sheboygan, WI 53081 Tel: 920-783-8340 Fax: 920-783-8339 New Jersey Unit 1, 1100 Taylors Lane, Cinnaminson, NJ 08077 Tel: 856-887-0544 Fax: 856-735-5584 As part of our continuous product improvement, regulation change or clerical error, IBC reserves the right to change specifications and design without notice. 900-041 (R3) Feb 28th 2018