INSTRUCTIONS FOR OPERATION AND CARE OF

Similar documents
INSTRUCTIONS FOR OPERATION AND CARE OF

INSTRUCTIONS FOR OPERATION AND CARE OF

INSTRUCTIONS FOR OPERATION AND CARE OF

INSTRUCTIONS FOR OPERATION AND CARE OF

INSTRUCTIONS FOR OPERATION AND CARE OF

INSTRUCTIONS FOR OPERATION AND CARE OF

INSTRUCTIONS FOR OPERATION AND CARE OF. P.O. Box 3527 City of Industry, CA, , U.S.A

INSTRUCTIONS FOR OPERATION AND CARE OF

INSTRUCTIONS FOR OPERATION AND CARE OF

INSTRUCTIONS FOR OPERATION AND CARE OF

Instruction Manual. Double Candy Apple Cooker

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

MANUAL FOOD HOLDING & TRANSPORT CABINETS WITTCO MODEL NUMBERS

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations

Electric Digital Kettle

OPERATING INSTRUCTIONS

Product Code: AP816. User Manual. T: F: Page 1 of 6

WATER BATH SP-1600-D April 2013

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Professional Warming Drawer and Warming Drawer Cabinet

ELECTRIC STOVE MODEL CGESS SAFETY INFORMATION AND OPERATION MANUAL

OPERATING INSTRUCTIONS

Instruction Leaflet. Heater with Adjustable Thermostat PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

Moving Rehabilitation Forward. Hydrocollator. HEATING UNITS User Manual 120 Volt Units E-2 SS E-1 M-4 M-2 SS-2 ISO CERTIFIED

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

MERIDIAN MODEL# 3793

Models: DB-2-HF, DB-3-HF, DB-4-HF, and DB-5-HF. For Service Information, Call

USE AND CARE GUIDE FOR MODEL MEK1, MEK15. Express Cordless Kettle

DELUXE ALTERNATING PRESSURE SYSTEM USER GUIDE

Cooler Mounted Bottle Fillers

A910.8A Remote Water Chiller, 8 GPH A A / A A-220V TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:

Operator s Manual. Model G17-EU (International) Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

OPERATIONS MAINTENANCE MANUAL

Instruction Manual. Portion Cup Cheese Warmer

OWNER S MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS WHOLE ROOM RADIATOR HEATER. Model: HO-0221 THERMOSTAT

Portable Heated Black Glass Shelves

OPERATIONS FOOD HOLDING & TRANSPORT CABINETS. wîttco foodservice. equipment

1.5 L Electric Kettle

Instruction Manual. Cheese Warmer with Pump

Compact Refrigerator. User's Manual PLEASE READ THIS MANUAL CAREFULLY BEFORE USING YOUR REFRIGERATOR AND KEEP IT FOR FUTURE REFERENCE.

hot air popcorn popper

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

MODEL NO: WD Warming Drawer, Rated 120V, 60 Hz,450W, 4A. Certificate Project Figure No. Version A

EcoBrite Smooth Light LED Light Fixtures

With Remote Control. English

Hot Dog Hutch. Models HDH-3, HDH-3DR, & HDH-4 owner s manual. Manufacturing Numbers:

TOASTER OVEN INSTRUCTION MANUAL. Model: MCSTO6B. 6 Slice

ELECTRIC STOVE HEATER Models: FS2213B

Instruction Manual. 36 in. and 42 in. Popcorn Staging Cabinets

A112408B/S-VR-UBL TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: Technical Assistance Fax:

PLEASE READ THIS MANUAL BEFORE USING YOUR APPLIANCE. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE.

Instruction Manual. Table Top Steamer Cart

Air Pump Up to 800 gallons

SAVE THESE INSTRUCTIONS

Earn BISSELL Rewards! Register your

SFH136-CN TRUSTED FOR OVER 100 YEARS. Sunbeam Heater. Instruction Leaflet PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

Use and Care Manual. Flammable Material Storage Refrigerator LRBFS06W1HC

INSTALLATION & OPERATING INSTRUCTIONS

V. (Versus ) Bare Floor Vacuum

PLEASE READ THIS MANUAL BEFORE USING YOUR APPLIANCE. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE.

InstructIon Manual KrEs EQuIPMEnt stands

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

SOUP COOKER/WARMER 120V, 240V MODEL 6423 INSTRUCTIONS. Installation Operation Maintenance

Earn Reward Points register your new

MC MC MC MC MC833130

Instruction Manual. Cheddar Easy All-In-One Cheese Corn Shop

1500 Watt OIL FILLER RADIATOR INSTRUCTION MANUAL. pure indoor living MODEL BOF2001-CN

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG)

Instruction Manual. Astro Staging Cabinet

ICE DISPENSER. Installation/Service Manual

SAVE THESE INSTRUCTIONS

UNDERCOUNTER REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

OWNER S MANUAL ELECTRIC FIREPLACE INSERT. Model No.: WESTERN (EF42D-45D) WARNING CAUTION

Installation Guide. Manufactured for Aero-Spa, LLC Web:

INSTRUCTIONS FOR OPERATION AND CARE OF

COH-267. COH-2670W Half Size Convection Oven

Natural Mist Humidifier. Vicks. (Model V3500) IMPORTANT! READ AND SAVE THESE INSTRUCTIONS. Use and Care Manual

e Bath Fan with Light User s Guide

Steam Mop USER S GUIDE 1867 SERIES. 3 Safety Instructions. Product View. Assembly 5-6. Special Features. Operation 7-8. Maintenance and Care 8-9

DOUBLE DOOR COMPACT REFRIGERATOR. User Manual MODEL:KSTRC312BW KSTRC312BB

With Remote Control. English. Model

(The chances are you re never going to read me) Owner s Manual. Model S10E.

e Bath Fan with Light User s Guide

Ultra Lightweight Household & Commercial Vacuums

EMERGENCY DRENCH SHOWER

NM A D E in MIC HIG A HL400 & HL800. Owner s Manual

Operator s Manual. Model G17 Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

8 lb Lightweight Vacuum Model CK LW 13/1

BIONAIRE HEATER. Instruction Leaflet. pure indoor living MODEL: BCH4130. Read instructions before operating. Retain for future reference.

ULTRASONIC HUMIDIFIER

froth tec Automatic Milk Frother

User Manual. Commercial Chest Freezer User s Manual 360CF5, 360CF8, 360CF14, 360CF18

Store Name: Location: Date Purchased: Serial Number (located on back of unit):

Manual Feed Slot Opening. Wastebin. Credit Card Casters

TWIN EAGLES WARMING DRAWERS INSTALLATION, USE, AND CARE MANUAL

Ozone + UV Sanitation

1600 Watt Professional

Instruction Manual. Dogeroo, Super Dogeroo, and Mini Dogeroo

Contents. Getting Started. Operation. Maintenance and Care. Problem Solving Guide. Warranty 13

Transcription:

INSTRUCTIONS FOR OPERATION AND CARE OF LITTLE Therm Compact Thermalator Model LT-4 800-782-7706 626-968-6681 www.whitehallmfg.com Whitehall Manufacturing is a Member of Acorn Engineering s Family of Companies. 6900-xxx-000 August 2010

Instructions for Operation and Care of Little Champ Compact Whirlpool TABLE OF CONTENTS Introduction...3 Model Descriptions... 3 Caution... 4 Warning... 4 Danger... 4 Setting Up... 5 Filling... 6 Emptying... 7 Checking Out My Little Therm... 8 Using the Thermal Pack... 8 Using the Wire Rack...10 Maintenance... 11 Cleaning and Sterilizing...11 Storage... 11 Troubleshooting... 12 Repair of Unit... 12 Parts Diagram Wiring Assembly... 13 Parts Diagram Final Assembly...14 2 WHITEHALL MANUFACTURING P.O. BOX 3527 City of Industry, CA 91744-0527 U.S.A Phone (800) 782-7706 (626) 968-6681 Fax (626) 855-4862 Web: www.whitehallmfg.com

Congratulations on receiving your compact Little Therm Thermalator. Little Therm is a simple and trouble-free unit to operate. The tank body, bottom and lid are all made from type 304 stainless steel with a thermostat on the rear to control the water temperature. Unit should be set for 160 F for normal operating temperature. Side handles and a knob on the lid minimize contact with the hot surface. The unit has Thermal Packs with colored tabs and an exposed heating element with a concealed temperature sensor. Unit rating is 120V, 8.3A, 50/60 Hz. White Tabs Thermal Pack Wire Rack Blue Tabs Lid Tank Body Indicator Light Hospital Grade Power Cord WHITEHALL MANUFACTURING P.O. BOX 3527 City of Industry, CA 91744-0527 U.S.A Phone (800) 782-7706 (626) 968-6681 Fax (626) 855-4862 Web: www.whitehallmfg.com 3

The instructions below are indicated by specific symbols. An understanding of these symbols, their companion text and the specific instructions and captions must be understood prior to operation of the equipment and patient treatment. CAUTION- Ignoring the following could cause injury or equipment damage. The table or cart must be level for proper and safe use.!! WARNING- These are safety infractions that could result in serious injury. DANGER- These are possible safety infractions if this equipment is used where flammable anesthetics are present. CAUTION All internal parts capable of transmitting electric current are grounded. Therefore, the electrical outlet to which the unit is attached must be properly grounded. Grounding reliability can only be achieved when the equipment is connected to an equivalent receptacle marked "Hospital Only" or "Hospital Grade". If there is any question as to the electrical protection, a qualified electrician should be consulted. Little Therm Compact Splint Pans are intended for use only where the person utilizing the treatment is under the supervision of trained personnel. DO NOT operate the unit dry - always make sure to fill with water before plugging in unit. Treatment temperature must be monitored closely and, of course, a patient's medical history must be reviewed, as with any heat modality, for heat sensitivity and circulatory problems. Do not use bleach or iodine based products to clean the tank as such products can quickly corrode the stainless steel tank resulting in pin holes and leaking water. Do not touch cord or plug if you are wet, standing in water or on a wet surface. Constant supervision is necessary when the unit is used with children, invalids, or any one who cannot safely operate the unit. WARNING Do not use the unit outdoors. Do not reach into water to get the thermal packs. Use the blue or white tabs or tongs. Do not place the Thermal Pack on bare skin. Always place the Thermal Pack in a terry cover. Refer service and electrical problems to qualified personnel and/or Whitehall Manufacturing only. Do not use if the unit, cord, or plug has been damaged. Return unit to Whitehall Manufacturing or a qualified service center. Do not use an electrical extension cord. Plug unit directly into a properly grounded receptacle. If there is any question on the grounding of the receptacle, call an electrician.! DANGER Always disconnect the line cord plug from the receptacle before working on any unit. Replace fuse as marked 10A/250VAC fast acting glass tube type. Do not operate any thermalator where flammable anesthetics are present. 4 WHITEHALL MANUFACTURING P.O. BOX 3527 City of Industry, CA 91744-0527 U.S.A Phone (800) 782-7706 (626) 968-6681 Fax (626) 855-4862 Web: www.whitehallmfg.com

SETTING UP 1. Your new Little Therm includes the following: 1 Little Therm Model LT-4 4 Thermal Packs (10" x 12") 1 Wire Rack - (stainless steel with vinyl coating) 1 Warranty Registration Card 1 Instructions for Operation and Care If you are missing anything, please call the phone number listed on the back page. 2. Unpacking your Little Therm Remove all the shipping material. Remove Thermal Packs and wire rack from inside the tank. Remove all packaging from inside the tank, especially from under the heating element inside the tank. Clean the unit thoroughly before using. 3. Device Placement: Place the Little Therm at a convenient level, such as on a table or a scratch resistant counter top. Before moving the Little Therm, unplug and cool the unit. Only move the unit to empty or fill it. Always use the handles. The unit may be hot to the touch. 4. Pre-Soaking Thermal Packs Before the first use, you must condition each Thermal Pack. Soaking in water lets the pack swell to its full size. This is necessary only BEFORE the first use. You can then reuse the pack after about 15 minutes of reheating. 1- Take the Thermal Pack by the corner loops - one white and one blue - so the sections are horizontal. 2- Gently shake the pack back and forth to evenly distribute the filler material. Shake to distribute the dry material 3- Place the Thermal Packs in a large metal pan to pre soak (use stainless steel or enamel-ware, DO NOT use aluminum) or plastic container. You may use the Little Therm for pre soaking. Place the Thermal Pack in the unit with sections horizontal. Change the water after soaking or water will become cloudy. 4- Fill the container with enough tap water to completely cover the Thermal Packs. 5- Soak the packs for 1 hour minimum, 2 hours or more is recommended. 6- Return the packs to upright position. The packs are now ready for heating. Turn the packs to upright WHITEHALL MANUFACTURING P.O. BOX 3527 City of Industry, CA 91744-0527 U.S.A Phone (800) 782-7706 (626) 968-6681 Fax (626) 855-4862 Web: www.whitehallmfg.com 5

FILLING 1 2 Make sure the unit is unplugged and all packaging has been removed. Fill unit about 3/4 full with tap water. 3 4 Place the wire rack inside the unit. Be careful of the heating element. Put the Pre-Soaked Thermal Packs on the wire rack. Place all the blue or white tabs up. 5 6 Add more water. if necessary, to cover the Thermal Packs. Uncovered packs may be damaged during heating. Close the lid. 6 WHITEHALL MANUFACTURING P.O. BOX 3527 City of Industry, CA 91744-0527 U.S.A Phone (800) 782-7706 (626) 968-6681 Fax (626) 855-4862 Web: www.whitehallmfg.com

7 Plug the power cord into an AC outlet. A Ground Fault Circuit Interrupter is recommended because it will give additional protection from electric shock. Indicator light should be illuminated. 8 AC EMPTYING 1 Unplug the unit. 2 Let the water cool to room temperature. Remove the Thermal Packs and the wire rack. Pick up the unit by the handles and pour out into a sink or floor drain. 3 WHITEHALL MANUFACTURING P.O. BOX 3527 City of Industry, CA 91744-0527 U.S.A Phone (800) 782-7706 (626) 968-6681 Fax (626) 855-4862 Web: www.whitehallmfg.com 7

CHECKING OUT my Little Therm Before the FIRST use, check the following: 1- The Little Therm should be level. 2- The Little Therm should be plugged directly into a properly grounded GFCI receptacle. Do not use extension cord. Undersized extension cords can overheat. 3- The Little Therm should be in good condition. Your new Little Therm is now ready for use. If you have any questions about SETTING UP or CHECKING OUT your unit, please call the phone number listed on the back page. USING the Thermal Pack 1- For each use: 1 Open the lid. Using tongs, carefully remove the Thermal Pack. 2 Caution: the Thermal Pack can cause skin burns. 3 Wrap the pack in a Thermal Pack Cover or 5 to 6 layers of terry toweling. 4 Put the wrapped pack on the area to be treated for a pre-set treatment time. 8 WHITEHALL MANUFACTURING P.O. BOX 3527 City of Industry, CA 91744-0527 U.S.A Phone (800) 782-7706 (626) 968-6681 Fax (626) 855-4862 Web: www.whitehallmfg.com

5 Remove the Thermal Remove the Thermal Pack Pack from the patient. Cover or toweling. Hang to dry or launder. 6 7 Open the lid.return the pack to the Little Therm. If the blue tab was up, put the white tab up now. Work your way from first to last, reversing tabs each time. Close the lid. The Thermal Pack will be reheated within 15 minutes and ready for use. 8 2- Daily use: 1 Add more water, if necessary, to cover the Thermal Packs. Uncovered packs may be damaged during heating. 2 Place all colored tabs in the same reference (either all up or all down) to start the day. BLUE WHITEHALL MANUFACTURING P.O. BOX 3527 City of Industry, CA 91744-0527 U.S.A Phone (800) 782-7706 (626) 968-6681 Fax (626) 855-4862 Web: www.whitehallmfg.com 9

3- Periodic use: The water temperature for normal operating conditions is about 165 F. The thermostat is very sensitive; even a small adjustment can raise or lower the temperature several degrees. To adjust the temperature, you need the following: Small, flat blade screwdriver Thermometer capable of 190 F 5 Facing the back of the unit, find the metal temperature knob between the 2 screws in lower right side of the unit. Using the screwdriver, turn the stem clockwise to increase the temperature. Allow the temperature to stabilize, and measure the water temperature with the thermometer. CAUTION: Sensitive thermostat; a small adjustment changes several degrees. 6 TEMPERATURE USING the Wire Rack Your Little Therm uses many different sizes of Thermal Packs. For Half, Cervical or Myofacia sizes, a small rack adapter is provided. For Standard, Knee/Shoulder, 10" x 18" and 10" x 24" sizes, use only the stainless steel wire rack provided. Half Small Rack Adapter (Optional) Cervical Myofacia Knee/Shoulder 10" x 18" 10" x 24" Standard 10 WHITEHALL MANUFACTURING P.O. BOX 3527 City of Industry, CA 91744-0527 U.S.A Phone (800) 782-7706 (626) 968-6681 Fax (626) 855-4862 Web: www.whitehallmfg.com

MAINTENANCE The Little Therm design is nearly maintenance-free. It should, under most conditions, give many years of reliable service. Clean and replace the Thermal Packs as described below. 1. Routine Maintenance (As Needed) See Cleaning and Sterilizing Destroy or discard any contaminated Thermal Packs. See Cleaning and Sterilizing Always keep the Thermal Packs under water. Replace any water that has evaporated. 2. Monthly Maintenance Clean wire rack and insert using mild soap. Rinse thoroughly with clean tap water. Dry with soft cloth. Scrub your Thermal Packs with warm soap and water. Keep the ph (a measure of acidity of the water) between 7.4 and 7.8 to reduce the scaling and residue build-up. 3. Yearly Maintenance Replace worn out Thermal Packs. When The packs begin to wear out, the non-toxic filler oozes through the fabric and seams. The individual cells seem empty. These packs don't hold the heat. Throw away worn Thermal Packs. Have a professional electrician thoroughly check the following: 1 - Test for leakage current, dielectric strength, and receptacle polarity and ground. If you need test need test details, call the number listed on the b a c k page. 2 - Check the power cord and plug. They should be free of cuts, abrasion and other damage. Replace the power cord assembly if it is damaged. Use only factory replacement parts. 3 - Remove the cover and check all electrical components and connections. Replace any parts that are in questionable condition. Use only factory authorized replacement parts. CLEANING AND STERILIZING Cleaning of the tanks can best be accomplished with a very mild, non-scratching household cleaner and a very low abrasion plastic scouring pad lightly applied. On a stainless steel tank, never use a metal scouring pad as it is too abrasive and may leave carbon metal deposits on the stainless which will rust. Again, disinfection and sterilizing is different from facility to facility, and we have found that alcohol is still the best (but expensive) cleaning and sterilizing solution. Bleaches and/ or iodine should not be used, but if they are if they must be that thorough rinsing of all metal parts be accomplished. Never should bleach or iodine be allowed to soak on the surface of stainless steel without the solution being immediately washed completely off. Initial evidence of excessive bleach and/or iodine use or lack of thorough rinsing will be a dulling appearance. Continued use of such practices will result in pin holes in the stainless steel tank and leaking. STORAGE 1. Storing the Little Therm See Cleaning and Sterilizing Place the Little Therm upright in a dry area away from any chemicals. 2. Storing the Thermal Packs Scrub your Thermal Packs with warm soap and water. Moist and Cold Dry 1 - Put the moist Thermal Pack in a plastic bag. 2 - Seal the bag. 3 - Store the bag in the freezer (recommended) or refrigerator. 1 - Air dry the Thermal Pack completely in a well ventilated area. The filler will become hard and caked. This doesn't hurt the bags; more Pre- Soaking time is then necessary. 2 - Store in a dry area away from any chemicals. WHITEHALL MANUFACTURING P.O. BOX 3527 City of Industry, CA 91744-0527 U.S.A Phone (800) 782-7706 (626) 968-6681 Fax (626) 855-4862 Web: www.whitehallmfg.com 11

TROUBLESHOOTING Problem Cause Solution Water doesn't get hot, even though unit is plugged in and switch is ON Circuit breaker is off Thermostat is not working Heating element is burned out Adjust the thermostat Replace the thermostat Replace the heating element Water is cloudy The Thermo Packs are worn out (seeping) Too long between cleaning Replace the Thermal Packs Drain, clean and refill Thermal Packs too hot The thermostat is set too high The thermostat is broken Adjust the thermostat Replace the thermostat Thermal Packs too hot and then too cool The thermostat is broken Replace the thermostat Thermal Packs too cool The thermostat is set too low The thermostat is broken There is a power failure Adjust the thermostat Replace the thermostat Check the circuit and turn on the breaker Rust in unit Contact with ferrous metal Remove the ferrous metal item from the unit -usually a staple, paper clip, safety pin, etc. Clean thoroughly. REPAIR OF UNIT It may be necessary or you may desire to return the Little Therm unit for service. In that case, we would appreciate you contacting Whitehall Manufacturing directly. We will make arrangements for the unit to be returned to our production location. When the unit is received by us, an estimate of repairs will be made and you will be contacted. Please- we appreciate warranty repair or any other repair be arranged directly with Whitehall Manufacturing. If you are not satisfied with our service, then and only then, contact your dealer. 12 WHITEHALL MANUFACTURING P.O. BOX 3527 City of Industry, CA 91744-0527 U.S.A Phone (800) 782-7706 (626) 968-6681 Fax (626) 855-4862 Web: www.whitehallmfg.com

Whitehall Part # Description 1 6505-546-000 10A/15A 250VAC C14 Snap-In Power Outlet 2 6900-135-000 Neon Indicator Light (Green), 125 VAC 3 6505-500-000 1000W 120V Tubular Heating Element 4 0710-450-000 1/2" Disc Thermostat, Auto Reset 5 0302-011-000 #6-32 UNC Stainless Steel Hex Nut 6 0322-003-000 #6 Plated Star Lock Washer (External) 7 0335-010-000.515 ID x.815 OD x.064 Thick Brass Washer 8 0440-000-000.515 ID x.875 OD x.064 Thick SBR Washer 9 0312-008-000 1/2-20 Jam Nut, Brass 10 6903-150-000 Operating Thermostat- Formasplint 11 6900-102-000 Clamp- Steel Cable 12 0710-230-001 Fuse Holder Assembly 13 6704-075-001 Wire Connector Assembly, Brown 14 5904-064-001 Wire Connector Assembly, Brown 15 6704-088-001 Wire Connector Assembly, Brown 16 5904-061-001 Wire Connector Assembly, Blue 17 5904-060-001 Wire Connector Assembly, Blue 18 6704-086-001 Ground Wire Connector Assembly, Green/Yellow 19 0710-108-000 Insulated Crimp Wire Connector 20 6704-077-001 Wire Connector Assembly, Brown 21 5904-065-001 Wire Connector Assembly, Blue 22 0710-216-000 Fuse, 10 Amp, 5mm 23 6505-056-000 Power Cord, 13A, 125V WHITEHALL MANUFACTURING P.O. BOX 3527 City of Industry, CA 91744-0527 U.S.A Phone (800) 782-7706 (626) 968-6681 Fax (626) 855-4862 Web: www.whitehallmfg.com 13

Whitehall Part # Description 1 6750-002-001 Thermalator Assembly (LT-4) 2 6702-040-199 Vinyl Coated Insert Rack 14 WHITEHALL MANUFACTURING P.O. BOX 3527 City of Industry, CA 91744-0527 U.S.A Phone (800) 782-7706 (626) 968-6681 Fax (626) 855-4862 Web: www.whitehallmfg.com

Mailing Address: P.O. Box 3527 City of Industry, CA 91744-0527 U.S.A Physical Address: 15125 Proctor Avenue City of Industry, CA 91746 U.S.A Phone 800-782-7706 626-968-6681 Fax 626-855-4862 Web: www.whitehallmfg.com E-mail: info@whitehallmfg.com Any questions regarding servicing of products in Europe or the Middle East should be directed to: Niva Medical Company Olarinluoma 14 B, FIN-02200 Espoo, Finland Phone 358 9 615 00 540 Fax 358 9 615 00 545 Web www.nivamedical.fi E-mail info@nivamedical.fi MANUFACTURER'S WARRANTY Whitehall Manufacturing Company warrants that its products are free from defects in material or workmanship under normal use and service for a period of one year from date of shipment. Whitehall's liability under this warranty shall be discharged solely by replacement or repair of defective material, provided Whitehall is notified in writing within one year from date of shipment, F.O.B. Industry, California. This warranty does not cover installation or labor charges, and does not apply to materials which have been damaged by other causes such as mishandling or improper care or abnormal use. The repair or replacement of the defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Whitehall under this warranty. Whitehall shall not be liable under any circumstances for incidental, consequential or direct charges caused by defects in the materials, or any delay in the repair or replacement thereof. This warranty is in lieu of all other warranties expressed or implied. Product maintenance instructions are issued with each fixture, and disregard or noncompliance with these instructions will constitute an abnormal use condition and void the warranty. Stainless steel must be protected on jobsites during construction and must be properly maintained after the water has been introduced into the fixture, or Whitehall's limited warranty is void. If you have any questions or require technical assistance, please call 800-743-8219. NOTICE TO KEEP ORIGINAL PACKAGING- Regarding warranty claims: customer must retain original packaging for one year upon receipt of product. If packaging is discarded, it is the customer's responsibility to provide adequate packaging. Any shipping claims that are a direct result of customer-provided packaging materials will be handled by the shipper. Whitehall Manufacturing is a Division of Acorn Engineering Company