EUROBOX SERIES TYPES CM... SM... MM...

Similar documents
EUROBOX SERIES TYPES CM...N SM...N MM...N

EUROFLAT SERIES TYPES C... S... M...

MICROFLAT SERIES TYPES C.../U T X

EURO-OIL SERIES TYPES G.. G../. OR.. OR../. F.. FR..

LGA... Gas Burner Controls. Siemens Building Technologies HVAC Products

LGA... Gas Burner Controls. Siemens Building Technologies Landis & Staefa Division

UV Flame Supervision System

Flame Safeguards LFE10. Building Technologies HVAC Products

Flame Safeguards LFE10. Building Technologies HVAC Products

LAE10 LFE10. Use. Series 02

C Note! LGI16... Burner Controls. Building Technologies

DKG 972. Gas Burner Safety Control. For 2-stage atmospheric gas burners

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

DMG 970. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners

LGA... Gas Burner Controls. Building Technologies Division

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

CATALOGUE PRODUITS - CSA - CSI - CSM - CSS - CSS2 - P16 - P19 - P20 - P25 - UV DETECTOR

LOA44.252A27. Oil Burner Control. Building Technologies HVAC Products

Gas burner automatic safety control MMI / 811.1

LFL Series Burner Flame Safeguard Control

MMI (40-34) Gas burner safty control

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

Oil Burner Controls LOA3... Building Technologies HVAC Products

Forced draught gas burner

LOA2... LOA3... Oil Burner Controls. Siemens Building Technologies Landis & Staefa Division

MMG Gas burner safety control

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

Oil Burner Controls LMO24... LMO44...

LC3000 Level Controller Installation and Maintenance Instructions

Forced draught gas burner

SERIES 35-63J APPLICATIONS FEATURES SPECIFICATIONS AGENCY CERTIFICATIONS

Oil Burner Controls LMO24... LMO44...

LOA2... LOA3... Oil Burner Controls. Siemens Building Technologies HVAC Products

Use. Burner controls for use with forced draught gas or gas / oil burners of small to medium capacity in intermittent operation.

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

DKO 974/976 DKO 974 N/976 N. Oil Burner Safety Control

AUTOMATIC BURNER CONTROL SYSTEM SAFETY INFORMATION CONFORMITY

No. Of Ignition Trials: No. Of Re-Ignition Attempts. Reset by interrupting power for 5.0 Seconds. Diagnostic Output. Re-Ignition Limit Exceeded

Gas Burner Safety Control DMG 970

Technical

BGH Series Hot Surface Ignition Control

24 VAC Intermittent Pilot Gas Ignition Control

SLATE. Burner Control Module INSTALLATION INSTRUCTIONS R8001B2001

Use. The burner controls are certified to EN 230 and EN 298.

Infrared Flame Detectors

Eclipse 90 UV Scanner Model A Version 1

New Power Vented Rheem FVIR Tanks

RE-PR3-E-27 3-Phase Panel Mount 27kW

Burner controls. Building Technologies HVAC Products

INSTALLATION INSTRUCTIONS FOR SERIES 9 INTERMITTENT PILOT IGNITION CONTROL

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

PRODUCT CATALOGUE. PACTROL SOLUTIONS New and Replacement electronics for the Gas Industry

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

Interrupted Ignition Series Oil Primary Control

QRC1... Blue-flame Detectors. Siemens Building Technologies HVAC Products

BENSON LINEAR RADIANT TUBE

Old documentation - Only for your information! Product is not available anymore!

7800 SERIES: EC7895A,C; RM7895A,B,C,D; RM7896A,B,C,D RM7897A,C and RM7898A Relay Modules

7800 SERIES 22-Terminal Universal Subbase

Oil Burner Controls LOA3... Building Technologies Division

SET-2000 Hi Level/Oil

7800 SERIES RM7840E,G,L,M; EC7840L Relay Module

INSTALLATION AND MANINTENANCE INSTRUCTIONS

FIREYE M4RT1 FLAME SAFEGUARD CONTROLS DESCRIPTION

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

Eclipse Self-Check UV Scanner

TECHNICAL SUPPORT: SERVICE BULLETIN #4 (v ) AB2017 HOT SURFACE IGNITION MODULE OVERVIEW

Operator: Save these instructions for future use!

RM7895A,B,C,D/EC7895A,C; RM7896A,B,C,D 7800 SERIES Relay Modules

RM7897A,C 7800 SERIES Relay Modules

OilSET-1000 (12 VDC)

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

LGB Gas fired boiler

Burner Management System

Quick Reference Guide. Application. Gas Furnaces Boilers Water Heaters Commercial Cooking. Features

Operator: Save these instructions for future use!

SAITEK srl. Serie. < Automatic burner control unit > Casalgrande (RE) ITALY Tel Fax

24 VAC Direct Spark Gas Ignition

DOMESTIC HOT WATER Follow operational sequence

7800 SERIES EC7895A,C; RM7895A,B,C,D and RM7896A,B,C,D Relay Modules

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

Gas Burner Controls. Building Technologies HVAC Products

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

Quickheat 30 weather compensated boiler control

Q7800H Integrated Burner Control Subpanel

Old documentation - Only for your information! Product is not available anymore!

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

7800 SERIES EC7890A,B; RM7890A,B,C Relay Module

Operator: Save these instructions for future use!

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

CUSTOMER SPECIFICATION

Intermittent Pilot Ignition (IPI) and Direct Spark Ignition (DSI) Applications with Flame Current Probes

GAS FIRED ATMOSPHERIC ELECTRONIC VERSION kw

LC2200 Level Controller Installation and Maintenance Instructions

Transcription:

EUROBOX SERIES TYPES CM... SM... MM... AUTOMATIC GAS BURNER CONTROL SYSTEMS FOR GAS BURNERS AND GAS BURNING APPLIANCES WITH OR WITHOUT FAN Application This range of electronic gas burner control systems has been designed specifically for atmospheric and fan assisted burners for intermittent operation (systems for nonpermanent operation ). All these controls are provided with non-volatile lock-out, which means that a restart from the safety shut-down condition can only be accomplished by a manual reset of the system. The automatic burner control units of this series are suitable for: -combi boilers -heating boilers -warm air generators -radiant heaters -water heaters Due to the design and the variety of models they can be used also for the automation of ovens, cookers and in general in gas firing installations with atmospheric burner. Features Table 1 shows the main features of this series. Other important features are: EC - Type certification (CE Reg. N 63AQ0625) in accordance with Gas Appliance Directives 90/396 and 93/68; in accordance with EN298 (European standard for automatic gas burner control systems); flame monitoring by the rectification property of the flame: ionization; two independent safety contacts in series on the gas valve output; electrical service life at max. loading >250.000 operations; inbuilt or remote reset facility; inbuilt ignition device completely of solid state design and high efficiency; auxiliary contact for low power ignition or main gas valve control for intermittent pilot systems (this contact is not isolated from the main supply voltage by reinforced isolation, therefore the relay contact is not suitable to supply SELV circuits - Safety Extra Low Voltage, e.g. 24V); different connections and fixings. 3989_r00 1/6

TABLE 1 BURNER RESET CONNECTION single flame dual flame atmospheric without fan atmospheric with fan auxiliary contact (1) single electrode external igniter remote inbuilt classification code according to EN298 (2) Socket P Socket R Socket NG Socket MG CM 191 * * (B) (A) AMCLXN * * * SM 191 * * * (A) AMCLXN * SM 192 * * (B) (A) AMCLXN * * * CM 381 * * (B) (A) FMCLXN * * * CM 391 * * (A) FMCLXN * SM 152 * * (B) (A) AMCLXN * * * SM 592 * * * (B) (A) AMCLXN * * * MM 191 * * * (B) (A) AMCLXN * * * MM 192 * * * (B) (A) AMCLXN * * * NOTE: (A) Box type xxxxx.1 - xxxxx.2 (1) : This contact is not isolated from the main supply voltage by reinforced (B) Box type xxxxx.3 - xxxxx.4 isolation, therefore the relay contact is not suitable to supply SELV circuits - Safety Extra Low Voltage, e.g. 24V. (2) : Flame failure during TS causes spark restoration. TECHNICAL DATA Supply Voltage: 230V-50/60Hz on request: 110/120V-50/60Hz Operating temperature range: -20 C +60 C Ambient humidity: 95% max at 40 C Protection degree: socket NG: IP 40 (after installation) socket P/R IP 00 Times: -Prepurge or waiting time (TW): 1,5/3/5/10/20/30/40 s the waiting time for type SM152 is: 3/5/10/20/30/40 s -Safety time (TS): 3/5/8/10/20/30/40/50/60 s -Drop out time on running flame failure: < 1 s The times given on the burner control label correspond to the values guaranteed. The actual values differ slightly from the values given, pre-purge and waiting times are in fact longer and safety time shorter than their nominal values. Power consumption, at starting up: atmospheric burner 10 VA atmospheric fan-assisted burner 12 VA Power consumption, running: atmospheric burner 7 VA atmospheric fan-assisted burner 9 VA Contact rating: I max -Thermostat: 4 A cos ϕ = 0.4 -EV1: 0.5 A cos ϕ = 0.4 -EV2: 0.5 A cos ϕ = 0.4 -EVG: 0.5 A cos ϕ = 0.4 -Fan: 1 A cos ϕ = 0.4 -Alarm: 0.5 A cos ϕ = 1 -Auxiliary contact: 0.5 A cos ϕ = 0.4 -External ignition: 1.5 A cos ϕ = 0.2 Max. length of the cables of external components: 1 m Fuse rating internal: 4 A Fast Fuse rating external: 3.15 A Fast Flame control: The ionization flame detector device makes use of the rectification property of the flame. The ionization flame detector device is not a safe to touch output (no provision with protective impedances). Minimum ionization current: 1.2µA on request: 0.5µA -Recommended ionization current: 3 5 times the minimum ionization current -Max. length of the cable: 1m -Minimum insulation resistance of cable and flame detector device to earth: 50MΩ -Max. parasitic capacitance of detection probe: 1nF -Max. short circuit current: < 200µA AC Ignition: -Ignition voltage: 8 KV at 30pF loading -Repetition rate: 25 Hz -Max.length of the cable: 2 m -Spark gap recommended: 2-4 mm -Consumption: 2,5 VA -Spark energy: 15 mj Weight: -with socket P or R: 220 g -with socket NG or MG: 275 g Controls for special applications: On request it is possible to meet special requirements concerning times, repetition rate of the sparks, minimum ionization current and operating cycle. CONSTRUCTION The enclosure made of plastic material protects the control from mechanical damage, dust and dirt from the conditions of installation.the particular construction, consisting of four printed circuit boards in order to form a "box" structure, has allowed a reduction in the volume of the control unit. A varistor protects the control from voltage transients on the mains supply. An internal fuse protects the relays of the control box in case of short circuits on the outputs (valves, fan and lock-out signal). This is not an accessible fuse and the control must be protected with a fuse of the fast blow type suitable to the load connected and never exceeding 3.15A. Overall Dimensions The control units of the EUROBOX series can be supplied with different executions of the enclosure depending on the functions and the fixing system required. 2/6 3989_r00

Enclosures are available with or without reset button and can be provided or not with fixing brackets on the sides. Please note that the control units with fixing brackets on the sides can only fit connecting sockets type P or R, as these are provided with suitable hooks. In the part reference the suffix describes the execution of the enclosure: 1 with reset button with fixing brackets 2 with reset button no fixing brackets 3 no reset button with fixing brackets 4 no reset button no fixing brackets The possibility to use the enclosures without the reset button is limited to those controls having the provision for remote reset. The following figure (fig. 1) shows the overall dimensions of the controls. screw terminal suitable for the CM381 control unit. Socket type P differentiates from type R on positions 8 and 10 for the presence of standard holes to suit female fast-on terminals of standard type (please see Fig. 4 and Fig. 5) Regarding the connection of the control units, provisions such as strain reliefs, sufficient earth terminals and neutral terminals should be present in the appliance or in external connection boxes. Socket R Fig.1 Accessories The control units are usually supplied with inbuilt reset button; there are versions with remote reset, with which we can supply a suitable illuminated reset button (see Fig.2). Cable holders/core hitches can be fitted on the sides of the enclosures (see Fig.3). These accessories can be supplied upon request. Socket NG Fig.4 RESET BUTTON DRILLING PLAN Socket NG RESET LOCK-OUT S. NEUTRAL Fig.2 Socket R Fig.5 Fig.3 Connection As regards the interconnection system, different solutions are possible; in fact, different types of connecting sockets can be used: type NG and MG with a screw terminal board or type P and R for fast-on terminals.the slots on socket R are suitable for female fast-on terminals.socket type MG differentiates from type NG for the presence of an auxiliary DIRECTIONS FOR THE USE For technical-safety reasons a regulation shutdown must occur every 24 hours (systems for non-permanent operation). Automatic controls are safety devices and shall not be opened. Responsibility and guarantee of the manufacturer is invalidated if the control is opened. The control must be connected and disconnected only without the main power. 3989_r00 3/6

The control can be mounted in any position. Avoid exposure of the control unit to dripping water. Ventilation and the lowest temperature ensures the longest life of the control Make sure that the type (code and times) you are using is correct before installing or replacing the control. For controls which are specified as IP00, the gas appliance in which the control is installed must provide adequate protection against the risk of electrical shock (at least IP20). Electrical installation The applicable national regulation and European standards (e.g. EN60335-1/prEN50165) regarding electrical safety must be respected. Live and neutral should be connected correctly, a mistake could cause a dangerous situation, i.e. the valves would still be live with the thermostats and limits switched off. Besides, if live-neutral polarity is not respected the control performs a non-volatile lock-out at the end of the safety time at starting up. Before starting check the cables carefully. Wrong connections can damage the control and compromise the safety. Take great care while connecting the lock-out signal and reset button: an inversion in the connection can damage the control. The earth terminal of the control, the metal frame of the burner and the earth on the mains supply must be well connected. Avoid putting the detection cable close to power or ignition cables. Use a heat resistant cable for the detection probe, well insulated to ground and protected from possible moisture (or water in general). Use an ignition cable as short and straight as possible and keep it far from other conductors to reduce the emission of electromagnetic interference (max.length <2m and insulation voltage >25KV). In case of live-neutral network with unearthed neutral or livelive network (with centre of the star not earthed) the control can operate correctly by means of a built-in resistor. IMPORTANT: in the event of "partial" short circuits or bad insulation between phase(s) and earth the voltage on the ionization probe can be reduced until it causes the lock-out of the control. In the presence of this kind of network it is advisable to use our isolation transformer type AR1. Checking at start Always check the control before the first start and also after substitutions or a long period of non operation of the system. Before any ignition attempt make sure that the combustion chamber is free from gas. Then make sure that: if the attempt to start occurs without the gas supply the control performs a non-volatile lock-out after TS; when stopping the gas flow (while the control is in running state) supply to the gas valve is interrupted within 1 second and after a recycling, the control proceeds to a non-volatile lock-out; operating times and sequence are suitable; the level of the flame signal is sufficient, see Fig.6 for the measuring test; the ignition probe(s) is (are) adjusted in the most stable way for a spark gap between 2-4 mm; the intervention of limiters or safety devices causes a safety shut-down according to the application. Fig.6 Operation At every start the control unit proceeds to a self-checking of its own components. During the pre-purge or waiting time the internal circuit makes a test of the flame signal amplifier circuit. A parasitic flame signal or fault in the amplifier prevents the control from starting. In the types with control of the fan, before the elapsing of pre-purge time, the air pressure switch contacts are checked to prove their "no air flow" state.only if the test is positive the fan is started and with the air pressure switch in "air flow" state, pre-purge time begins. At the end of the waiting or pre-purge times the gas valve is energized and the ignition device is operated. If a flame is detected during the safety time the ignition device is inhibited and, in the suitable models, the indipendent auxiliary contact will switch from off to flame detected position or the second gas valve will be energized. On the contrary, if the control doesn't detect a flame by the end of TS, it proceeds to non-volatile lock-out, the gas valve and the ignition device are switched off while the lock-out signal output is supplied. When the flame fails during the safety time, then the ignition device is activated within one second. The attached diagrams are useful to understand how each control operates. Reset of the control When a control has gone to non-volatile lockout, an interval of 10 seconds should be allowed before attempting to reset the control unit; if this time is not observed then the control may not reset correctly. 4/6 3989_r00

CONNECTION DIAGRAMS NOTE: the limit thermostat has to be wired in series to the live. 3989_r00 5/6

OPERATING CYCLES Eurobox Series Types CM... SM... MM... 6/6 3989_r00