DIGITAL-FLO SEMI-INSTANTANEOUS VERTICAL HOT WATER

Similar documents
WATER HEATING & WATER TEMPERATURE CONTROL DIGITAL & FEED-FORWARD

DIGITAL HOT WATER SOLUTIONS

SECTION. Hot Water ARMSTRONG PRODUCT CATALOGUE

Intelligent System Solutions Steam Air Hot Water

ADMS. AERCO Digital Mixing Station. AERCO.com

DigiTemp. Digital Water Tempering System. PVI.com

Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water

TECHNOLOGY GUIDE. :: the dawn of a new era in commercial HVAC technology. The all-new Rheem Commercial Renaissance Line featuring:

Heat Transfer Packages

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

ecocirc XL HIGH EFFICIENCY LARGE WET ROTOR PUMP FOR HEATING, COOLING AND POTABLE WATER SYSTEMS A-162C

IntelliStation. The Smart Mixing & Recirculation System. For Domestic Hot Water in Commercial and Institutional Facilities. PowersControls.

Packaged Semi-Instantaneous Steam Fired Water Heater

TECHNOLOGY GUIDE :: THE DAWN OF A NEW ERA IN COMMERCIAL HVAC TECHNOLOGY. The all-new Ruud Commercial Renaissance Line featuring:

Submittal S-NV-150-LF-M November, 2018 MEGATRON MODEL NV-150-LF DIGITAL TEMPERATURE CONTROL STATION

I/O ZONE 560/583 USERS GUIDE

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

Submittal S-NV-200-LF-M DIGITAL TEMPERATURE CONTROL STATION. Valve assembly is ASSE 1017 Certified. Valve assembly is cupc Certified

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

C SINGLE-POINT HEAT-TRACING CONTROL SYSTEM. product overview

SECTION PACKAGED HEAT TRANSFER SYSTEM

EZ Plate Instantaneous

Water-Cooled Modular Chillers. Product Data Catalog. Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X

INDUSTRIAL HOT WATER SOLUTIONS

DGC-1000 DIGITAL GENSET CONTROLLER

Hoffman Specialty General Catalog

Digital Hot Water Systems

TABLE OF CONTENTS STEAM TRAPS INVERTED BUCKET SERIES PAGE FLOAT AND THERMOSTATIC SERIES PAGE THERMOSTATIC THERMODISC B0 26. How to Select All 107

Med Touch Master Alarm

Advanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module

DIVISION FINNED WATER-TUBE BOILERS

INDIRECT FIRED EQUIPMENT INSTALLATION FORM

Conquest. Condensing Gas Water Heater. 199 to 300 MBH 100 Gallon Tank 15-year Warranty. PVI.com

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER. Compact Design. High Recovery. Energy Efficient. Stainless Alloy Construction

EZT Series Integra Med Touch Area Alarm & Zone Valve Box with EZ Backfeed

Tri-Tech Medical Inc.

SEH Series. Stainless Steel Instantaneous Packaged Steam Fired Water Heaters

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

SENTRA Series Water Unit

CONDENSING HIGH EFFICIENCY BOILERS

Touchpoint Pro Flexible Gas Control System

PLC / HMI Modbus (Slave) Addressing

POWER VTX. Condensing Storage Water Heater. 500 to 1000 MBH 225 Gallon Tank 15-year Warranty. PVI.com ENGINEERED DUPLEX ALLOY

FLEXIBLE, AFFORDABLE, HIGH SPECIFICATION OXYGEN GAS ANALYSIS DESIGNED FOR DEMANDING HAZARDOUS AREA PROCESS CONTROL APPLICATIONS.

Rada 320R Installation and Maintenance

BURNHAM COMMERCIAL 27 February 2008 MPC Multiple Pass Commercial Boiler Suggested Specifications

Hubbell NX500 High Efficiency Gas Condensing Water Heater

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

NH Series. Installation and Operation Manual

CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated)

Liebert PPC Second Generation Power Distribution Cabinet

Project Name: Location: Engineer: Contractor: I. GENERAL

Integrated Automation Instrumentation & Terminal Devices

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

FINNED WATER-TUBE POOL HEATERS

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

SECTION DOMESTIC WATER PIPING SPECIALTIES

DIVISION FINNED WATER-TUBE BOILERS

PRESSURE FOG HIGH ATOMIZING HUMIDIFICATION SYSTEM

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

SmartVFD HVAC and BYPASS

DIVISION FINNED WATER-TUBE BOILERS

Centro-Matic Automated Lubrication Systems System Controls

Sequence of operation

Pressure Steam Humidifiers. Designed to deliver reliable humidity from facility steam boilers. Live Steam

Guide Specifications PART 1 - GENERAL 1.01 SUMMARY

Liebert Mini-Mate2. 8-Ton (28kW) Capacity, Air, Water, Glycol, GLYCOOL, Chilled Water; 50 & 60 Hz. Technical Data Manual

EC-BOS-602/616 AX Security

High Pressure Conductivity Monitor

DIVISION FINNED WATER-TUBE BOILERS

OPTIMUM APPLIED SYSTEMS,

Catalog HW-410. Generation Distribution Control

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

Med Touch Combination Alarm Conversion Kits

CONDAIR RS. Resistive steam humidifier With advanced scale management. Humidification and Evaporative Cooling

ONQUEST. Featuring... Condensing Water Heater. Requires no tank linings or heat exchanger linings. Requires no anodes of any type. 10- year warranty.

K-Controller Brochure.qxp_ Controller Brochure 2/27/17 3:03 PM Page 4 Versa IC Platform

Gas Detection. Touchpoint Plus. A whole new control experience

Tried, true, and trusted for over 40 years. EL Series Electrode Steam Humidifier. Humidification and Evaporative Cooling. humidity.

FLO-RITE-TEMP INSTANTANEOUS WATER HEATER INSTALLATION AND ADJUSTMENT INSTRUCTIONS FOR SINGLE AND DOUBLE WALL UNITS

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

AS950 REFRIGERATED SAMPLERS

Dual-point heat-tracing control system

Less Than.25% Lead Proudly Assembled in the U.S.A

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications

EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

Document # R01

910 Series Single-point heat-tracing control system

Powerful intelligence. Breakthrough functionality. SV2 Series Intelligent Safety Shut-off Valve

Flo-Rite-Temp Instantaneous Steam/Water Heater

AS950 PORTABLE SAMPLERS

Dräger Polytron 8100 EC Detection of toxic gases and vapors

The integral solution for. Air Handling Units. Technology & Evolution

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

GAS FIRED HUMIDIFIER. Advantages. Typical Applications. Typical Installation

Transcription:

DIGITAL-FLO SEMI-INSTANTANEOUS VERTICAL HOT WATER

Armstrong blends revolutionary digital water temperature control technology with a semi-instantaneous heat exchanger to deliver Armstrong s first Vertical Series of Steam Water Heaters. Digital-Flo Semi-Instantaneous (DFS) uses digital technology featuring The Brain Digital Recirculating Valve (DRV) to offer a level of hot water system temperature control accuracy previously considered unattainable. DFS is SAGE ready and compatible with Building Automation Systems. Armstrong Digital Technology Powered by low voltage electronics Quick response times eliminate the need for pneumatic control valves Programmable high/low temperature alert function Programmable hot water system safety shutdown Self diagnostic display messaging SAGE hot water system monitoring and reporting tool Simplified system commissioning Armstrong Heat Exchange Technology Constant steam pressure provides positive condensate drainage Low surface temperature option for hard water applications Water raised above Legionella survival temperature Vertical configuration means smaller footprint No overhead clearance needed for tube bundle removal Connectivity SAGE - Hot Water System Monitoring and Reporting Tool. For Building Automation Systems Interface module available with Building Automation System (BAS) specific ProtoCessor cards for systems which operate on the Modbus, BACnet, or LonWorks protocols. For the Web Dashboard operable, smart hot water system monitoring and reporting software that works seamlessly as it analyzes data to track behavior and performance ensuring full compliance with ASHRAE, VA and World Health Organization hot water system safety guidelines. DFS35DW40 DFS3540 Single Wall and Double Wall Tube Bundle Available. 2

316L body construction Lead Free +/-2 F/1 C water temperature control Hot water shutoff upon power failure Output display Set point Operating temperature Over/under temperature alert RS485 port: Integral Modbus RTU Protocol Serial port to connect Sage for Bacnet, LonWorks, and web access LCD display Error message display Over temperature error PCB error Thermister error Motor error/emergency mode Battery error SPCO relay contacts Integral relay for auxiliary device (alarm, solenoid) ASSE 1017 CSA B125 CE UL Battery back-up for emergency shutdown and programmed settings retention upon power failure DB9 Port for valve programming: Set point Two level temperature alert Thermal disinfection Default settings Recirculating Valve (DRV40 & DRV80) 3

Specifications Digital-Flo Semi-Instantaneous Shell & Tube w/ Single-Wall, Tube Bundle Water Side Connections @ 7.5ft/sec [2.3m/s] Steam Side Connections Model Hot/Cold Recirc. HX Capacity @ 100ºF [55ºC] Delta T* Max Package Capacity at 120ºF [49ºC] Blend Outlet* Steam/ Condensate Inlet/Outlet Capacity @ 15psi [1bar] DFS1540 1 [25mm] 1 [25mm] 14gpm [53lpm] 18gpm [68.1lpm] 2 [50mm] 737lb/hr [334kg/hr] DFS3540 1.5 [40mm] 1 [25mm] 27gpm [102lpm] 35gpm [132.5lpm] 3 [80mm] 1421lb/hr [645kg/hr] DFS5050 2 [50mm] 1.5 [40mm] 46gpm [174lpm] 60gpm [227.1lpm] 3 [80mm] 2421lb/hr [1098kg/hr] DFS9080 3 [80mm] 2 [50mm] 84gpm [318lpm] 106gpm [401.3lpm] 4 [101.6mm] 4422lb/hr [1714kg/hr] *Assumes 40 to 140ºF [4.4 to 60ºC]; Using Blend Formula w/ a mixing valve setpoint of 120ºF [49ºC] to determine Max. Package Capacity Digital-Flo Semi-Instantaneous Shell & Tube w/ Double-Wall, Tube Bundle Water Side Connections @ 7.5ft/sec [2.3m/s] Steam Side Connections Model Hot/Cold Recirc. HX Capacity @ 100ºF [55ºC] Delta T* Max Package Capacity at 120ºF [49ºC] Blend Outlet* Steam/ Condensate Inlet/Outlet Capacity @ 15psi [1bar] DFS15DW40 1.5 [40mm] 1 [25mm] 14gpm [53lpm] 18gpm [68.1lpm] 2 [50mm] 737lb/hr [334kg/hr] DFS35DW40 1.5 [40mm] 1 [25mm] 27gpm [102lpm] 35gpm [132.5lpm] 3 [80mm] 1421lb/hr [645kg/hr] DFS50DW50 2 [50mm] 1.5 [40mm] 46gpm [174lpm] 60gpm [227.1lpm] 3 [80mm] 2421lb/hr [1098kg/hr] DFS90DW80 3 [80mm] 2 [50mm] 84gpm [318lpm] 106gpm [401.3lpm] 4 [101.6mm] 4422lb/hr [1714kg/hr] *Assumes 40 to 140ºF [4.4 to 60ºC]; Using Blend Formula w/ a mixing valve setpoint of 120ºF [49ºC] to determine Max. Package Capacity Operational Limitations (all models): Steam pressure, maximum allowable = 150 PSIG (10 barg) and maximum operating = 15 PSIG (1 barg) Water pressure, maximum allowable = 150 PSIG (10 barg) Setpoint temperature, maximum allowable = 158 F (70 C) Factory connections are US nominal pipe sizes (NPS) w/ ANS taper pipe threads (NPT) or ASME/ANSI B16.5, Class 150, bolted flange connections, as noted. The nearest equivalent pipe sizes in SI (the metric system), known as diametre nominel, are listed in parentheses. Consult factory for pressure drop information. 4

Dimensions Dimensions and Weight Model Dimensions In (mm) A B C D E DFS1540 23.5 (598mm) 86.0 (2185mm) 43.9 (1116mm) 44.4 (1129mm) DFS3540 25.0 (636mm) 86.9 (2207mm) 48.5 (1231mm) 48.8 (1240mm) DFS5050 26.1 (663mm) 88.4 (2245mm) 56.7 (1440mm) 54.6 (1387mm) DFS9080 29.6 (752mm) 91.5 (2324mm) 57.6 (1463mm) 65.4 (1662mm) 16.4 (416mm) 17.1 (434mm) 18.8 (477mm) 4.4 (113mm) F G H I J DFS1540 21.3 (542mm) 80.8 (2052mm) 42.8 (1087mm) SW=21.1 (536mm) DW=20.3 (515mm) 35 (899mm) DFS3540 22.8 (578mm) 81.4 (2067mm) 45.3 (1150mm) SW=19.2 (488mm) DW=18.4 (467mm) 35 (899mm) DFS5050 25.5 (646mm) 82.6 (2098mm) 46.8 (1189mm) SW=17.3 (439mm) DW=16.3 (413mm) 35 (899mm) DFS9080 28.0 (712mm) 81.7 (2076mm) 49.6 (1259mm) SW=15.4 (390mm) DW=14.4 (365mm) 35 (899mm) All dimensions apply to both single wall and double wall units. Refer to drawings on previous page for locations. 5

Specifications Matrix Digital-Flo Semi-Instantaneous Vertical Optional Standard Optional Model Heat Exchanger Double-Wall Tube Bundle DRV SAGE For Building System (BS) Integration DFS 15 DW 40 BS DFS 35 DW 40 BS DFS 65 DW 50 BS DFS 90 DW 80 BS Example of heater package Single-Wall Tube Bundle, with SAGE : DFS1540BS Example of heater package Double-Wall Tube Bundle, without SAGE : DFS15DW40 6

INTELLIGENT SOLUTIONS IN STEAM, AIR AND HOT WATER Armstrong International North America Latin America India Europe / Middle East / Africa China Pacific Rim armstronginternational.com 2016 Armstrong International, Inc. HW-428-E-EN Printed in USA - 6/16