CT398 Heaterstat TM Temperature Controller. Technical User Guide

Similar documents
OVEN INDUSTRIES, INC.

LineGuard 2300 Program User Manual (FloBoss 107)

TEC2100 Series Networked Thermostats

UNC100 Integra Manual

Mark 25 Ultrapure Water Conductivity Analyzer

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs

ND4000 Manual Marine Hydraulics

ENGINE MONITOR VOTT MODEL: YEAR WARRANTY

OPERATING MANUAL Enertronic Control System 2

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV

CT224 Setup Tutorial

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

PGR-8800 TECHNICAL FAQ

M1000 Alarm Annunciator

Ethernet General Purpose

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

TEC210x-2 Series Networked Thermostats

DGC-500 DIGITAL GENSET CONTROLLER

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

Analog Room Pressure Monitor RPC Series

VMB1TSW Temperature sensor module for the Velbus system

MicroTech Series 200 Centrifugal Chiller

JDDT1 - Single Stage Digital Thermostat

Laptop / PC Programming Manual

Carbon Monoxide Transmitter

Watchguard WGAP864 User Manual

Module Features are-configurable, no module jumpers to set

Product Manual SZ1145

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.

Dryer Master DM510 Commissioning Guide

Specifications Minimum Typical Maximum Unit

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.

Product Manual SZ1009

WeatherLink for Alarm Output Addendum

Rev Pulse Modulating Anti- Sweat Control (PMAC II) Installation and Operation Manual

Description of the application programme for KNX occupancy detectors version 3.1

The data logger is supplied with a lithium metal battery which typically gives two years logging life.

No. Icon Name Function

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504

Product Manual SZ1144

PACSystems* RX3i. Thermocouple Input Module, 12 Channels, IC695ALG412. GFK-2578B October 2011

IntelliPack : 800 Series

Dryer Controller M720

The Information Contained in this Document is Proprietary and should only be used for Service or Training of Authorized Blodgett Servicers who will

Speed and Frequency Seite 1 von 7

TCII micro-temperature Controller INSTRUCTION MANUAL

B.E.G. LUXOMAT KNX-OCCUPANCY DETECTOR

EL-OEM-3 OEM Packaged Voltage Data Logger

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Rev Pulse Modulating and Anti- Sweat Control (PMAC II Solo) Installation and Operation Manual

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

T-32-TS Touchscreen Thermostat. Installation Manual

User Manual. Dryer Controller M720

T500 Elite MANUAL (Software Version 3.0.9)

PTE0705 Electric Fence Monitor

Introduction. OM-THA2

Air Comfort. Installation instructions (English) A

TraceNet ECM Series Control System

OPERATING MANUAL Enertronic Control System 2

HOBO U14 Data Logger User Manual

ProTalk. Expander. Operating Manual Model B1292. July 28, 2009 Rev. 1.01

20 Light Remote Annunciator

DEIF A/S. Description of options. Option M17, Configurable inputs and RPM supervision Engine Controller EC-1/EC-1M. Description of option

Model 1062 Environment Monitor

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

REPEATER FS5200R INSTRUCTION MANUAL

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

RTD TEMPERATURE SENSING SYSTEM

Operations Manual TS400. Test Station for G450/G460 Gas Detector

HRX Technical Manual. Version 1.2

Oxygen (O2) Single-Point Gas Detection System

RS485 MODBUS Module 8AI

QD-ENG-68 Controller for Thermoelectric Thermal Management

FUNCTIONAL SAFETY MANUAL

AXS Strikemaster Engineering Manual

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Analog Input Module IC670ALG630

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Micro-controller X C C1 C2 AL1 AL2 AL3. Model: PXR4/5/9. Operation Manual SEL PXR. ECNO:406e

ESSEX ENGINEERING CORPORATION

DGC-1000 DIGITAL GENSET CONTROLLER

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

T600MEP-2 Programmable Economizer Thermostat

FlameGard 5 UV/IR HART

CBI-064. User Manual. Caddx to KNX-BUS Interface

AS950 REFRIGERATED SAMPLERS

Dry Contact Probe DCP (#30008)

Specification for On-Line UPS Battery Monitoring and Data Management System

General Purpose IO Technical Manual

Series DCT1000DC Dust Collector Timer Controller Specifications Installation and Operating Instructions

Comfort System T-21-P Touchscreen Thermostat Installation Manual

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

Digital Heater Element Burnout Detector K8AC-H

2-wire Passive Intelligent Loop (LED) Display Meter

Instruction Manual PCS-400-XY. Pump Controller. Y=2: 4-20 ma Y=6: 0-10 VDC X=5: 1-5 VDC. 4 Pump Control Relays 1 Alarm Relay 1 Signal Fail

Transcription:

CT398 Heaterstat TM Temperature Controller Technical User Guide

CT398 HeaterStat Controller Contents CT398 HeaterStat Controller... 2 Contents... 2 Document Overview... 2 For More Information... 2 Introduction... 1 Document Overview This document provides an overview of how to use the CT398 DC HeaterStat. For More Information For more information on the contents of this document, please contact your local Minco representative. Conventions... 1 Installation... 1 Mounting... 1 Wiring... 1 Configuration... 2 Status... 2 Heater Settings... 3 Output Settings... 4 General Usage... 5 Status/Communication LED... 5 Frequently Asked Questions (FAQ)... 6 Specifications... 7 Inputs... 7 Outputs... 7 Communication... 7 General... 7 Glossary... 8 2

Introduction The CT398 is a programmable sensorless temperature controller designed to operate on DC power. When a high TCR (Temperature Coefficient of Resistance) heater is used with the CT398, the heater element serves as the temperature sensor which completely eliminates the need for a separate sensor during operation. An optical communication interface allows for easy configuration on a computer; the included Windows software provides multiple methods of characterizing a heater and configuring the Setpoint to any desired value. The CT398 utilizes the same footprint as Minco s original HeaterStat, the CT198; however, the CT398 is shorter, has a higher current rating, and has full programmability: All settings can be programmed and changed by the user. The CT398 utilizes on/off control by applying power to the heater element when the measured heater resistance, which increases with temperature, is below the Setpoint. When power is applied to the heater, the resistance of the heater is constantly being measured. When the measured element resistance is above the Setpoint, power is disconnected from the heater except for during the Measurement Pulse. The Measurement Pulse is a momentary application of heater power for the purpose of measuring the heater element resistance. See the Output Settings and FAQ sections for more information on the Measurement Pulse and Pulse Heating. Depending on the characteristics of the thermal system, the difference between the heater element temperature and the heat sink may vary significantly. Since the CT398 directly measures the heater element and applies the control output accordingly, care should be taken to ensure that the overall system is controlled to the desired operation using external validation. The CT398 is ideal in situations where additional wires for a sensor are undesirable, or where precise temperature control is unnecessary and simplicity is important. Conventions Different typestyles are used throughout this manual to make it easier to convey whether the text refers to a physical feature of the CT398, or if it refers to a general term. A word or phrase with first letter capitalization (such as Heater Output) refers to a feature on the CT398 such as a terminal block connection or a feature such as Device Name. Installation All configurations are performed through the optical communication interface (AC221332, available separately) and the Windows application. The CT398 must be powered, and its LED must be accessible to perform any configuration. Mounting The CT398 may be mounted via the mounting hole if desired and may be operated in any position. A minimum of 1 inch (2.5 cm) airspace must be maintained around the sides and top of the CT398. An exception is if a contacted surface is maintained at or below the assumed ambient temperature. Wiring Only three wire connections are required: Power, Ground, and Heater. Each connection is explained in the following sections. page 1 2015 Minco 360-00129(-) minco.com

Power This connection provides power to the CT398 electronics and is used to monitor the heater voltage. To accurately measure the heater resistance, this connection must be as close as possible to the heater s positive side; the preferred method is to connect this terminal directly to the heater and directly to the power supply using separate wires. See Figure 1 for a connection diagram. Ground This connection is the return path for the heater current and CT398 electronics. Therefore, ensure the wire used is adequately sized to carry the heater current. Heater This connection is for the heater s negative (return) side. It is an open-drain output that sinks current to the Ground connection. As with the Ground connection, ensure the wire used is adequately sized to carry the heater current. Typical Wiring Diagrams Below is a typical wiring diagram for the CT398. Figure 1 Configuration A separate programmer, model AC221332, is necessary to configure the CT398. This device optically communicates with the CT398 though the Status/Comm LED. To use, connect the programmer to a computer with a USB Cable and place the programmer LED interface tubing over the CT398 s Status/Comm LED. Then, using the HeaterStat Utilities software, press Connect to Device. If this is successful, the configuration stored on the CT398 is retrieved and displayed, along with the calculated temperature and output status. The settings are separated into groups: Status, Heater Settings, and Output Settings. Status The Status group displays the heater s measured resistance and output status. The Heater Output status will indicate if the Heater Output is energized while attempting to increase its temperature, but not while the CT398 is pulsing the output to test the heater resistance. See Figure 2. If the heater is properly defined within the Heater Settings tab, the status page will also display the calculated temperature based on the measured resistance. page 2 2015 Minco 360-00129(-) minco.com

Figure 2 Heater Settings The Heater Settings group contains various methods CT398 Utilities may use to convert heater resistance to temperature. The different methods are outlined below; only one method is required if this feature is desired by the user. Alternately, the CT398 s Setpoint may be defined by heater resistance only (See Output Settings), meaning the entire Heater Settings group may be ignored. Each method is accessed by the tab of the same name. The last selected tab within Heater Settings (Heater Code, Heater Characteristics, Temperature/Resistance Data, or Equation) defines which method the program uses to convert resistance to temperatures. Heater Code: A string of characters which, if provided with the heater, fully describes the heater s characteristics. This code must be received from Minco. Heater Characteristics: The heater element composition, base resistance, and optional calibration data points are used to characterize the heater. Temperature / Resistance Data: A set of temperature / resistance pairs are entered and used to characterize the heater. A minimum of two temperature / resistance pairs are required, although more increases accuracy. Equation: Polynomial coefficients are entered and used to characterize a heater. The equation relating heater resistance to temperature must be known to use this method. page 3 2015 Minco 360-00129(-) minco.com

Figure 3 Output Settings The Output Settings group contains Device Name, parameters which directly control the Heater Output, and parameters which define Status/Comm LED behavior. Device Name: A string of up to 20 characters that the user may use to name the device. This may be useful to identify multiple units. Pulse Rate: The period of time between Measurement Pulses with which the CT398 tests the heater resistance while the output is off, i.e. while the heater resistance is above the Setpoint. This value is in milliseconds. When the heater s resistance is below the Setpoint, the heater is energized and its resistance is checked continuously at a high, fixed rate. Generally a lower Pulse Rate period is better since it should theoretically result in tighter control; however, the lower the Pulse Rate period, the greater the Pulse Heating effect. A Pulse Rate period of 1000ms is a recommended starting point. LED Behavior: Determines the LED behavior when used as a status indicator (when not being used for PC communication). The options are as follows: Mode 1: LED to remain off during normal operation. Mode 2: LED indicates when output is on for the purpose of heating, but not including the Measurement Pulses. Mode 3: LED indicates when output is on for the purpose of heating, including the Measurement Pulses. Mode 4: LED displays a fade on-fade off behavior when the heater resistance / temperature falls within the Process Value Range and there are no errors. This is useful as a quick visual check to ensure the CT398 is operating as desired. Additionally, if the Heater Shutdown range is violated or Analog to Digital Converter fails, the associated error code will be displayed on the LED regardless of the Mode chosen. Control Units: Selectable between Resistance and Temperature. This setting controls whether resistance or temperature is used to configure the Setpoint, Process Value Range, and Heater Shutdown limits. If Temperature is used, the Heater Settings information must be entered. If Resistance is used, no information about the heater is required by the utility program. The Setpoint, Process Value Range, and Heater Shutdown values on the same screen will be displayed / entered in the selected units. page 4 2015 Minco 360-00129(-) minco.com

Setpoint: The desired resistance or temperature of the heater. If this value is higher than the heater s measured value, the heater is energized until this is no longer true. If this value is lower than the heater resistance, the Heater Output is pulsed to monitor the resistance. Process Value Range: The lower and upper limit at which the LED will fade on-fade off when configured to do so. Heater Shutdown: The lower and upper limit at which normal operation will continue. If the heater falls outside of these limits, the CT398 goes into Heater Shutdown and power must be cycled to resume operation. It s recommended to set these to values that would indicate a problem with the heater. This feature is temporarily suppressed when HeaterStat Utilities is connected to a CT398. Figure 4 General Usage Status/Communication LED The LED present on the CT398 serves as a status indicator by default, but will switch into communications mode if a Minco Optical Communication Accessory (model AC221332) is attached to the LED. This is the method by which information is moved to and from the CT398 via the Windows CT398 Utilities. The LED is capable of different behaviors, configurable by the user. It also will display various error messages should that occur, see Table 1. NOTE: It is normal for the Status LED to exhibit a slight periodic flicker when lit. This is a result the CT398 periodically checking for communication attempts from the Optical Communication Accessory. page 5 2015 Minco 360-00129(-) minco.com

Pattern Three flashes, each of increasing length Alternating low brightness and high brightness Brief high brightness flashes Fade On/Fade Off Meaning In manufacturing mode. This should not occur during normal operation. Analog to Digital Converter failure. This is easily caused by low supply voltage, but could also indicate hardware failure. Ensure supply voltage is within specification and cycle power. An out of bounds error has occurred due to the Heater Shutdown limits. This can also occur if the maximum current rating is exceeded. Heater resistance/temperature is within Process Value Range limits, and no errors are active. Available only in LED Mode 4. On solid or semi-random Power is applied to heater. Available only in LED Modes 2 and 3. flashes of low brightness Off No power applied, Heater Output is de-energized, or LED in Mode 1. Table 1 Frequently Asked Questions (FAQ) Q: How long will the CT398 maintain configuration in non-volatile memory? A: The specification states the retention is at least 20 years and will withstand at least 1 million writes. Q: Why isn t the measured temperature of the heater surface the same as what is reported in the utility program? A: The CT398 uses the resistance of the heater s element to determine the heater s temperature. It is not uncommon for this measured value to be higher than the heater s surface temperature. External characterization of the setup is often required to correlate heater element and heatsink temperature. Q: Why does the temperature slowly increase despite already exceeding the Setpoint? A: Try increasing the Pulse Rate period. In order to measure the heater s resistance, power is briefly supplied to the heater and the current and voltage are measured. If the CT398 checks too frequently and the heater / heat sink is relatively small, this will result in excessive heating. Q: Can any heater be used with the CT398? A: Provided the applied voltage and heater resistance does not exceed the CT398 s output current rating, yes any heater may be used as long as it uses a high TCR element. If a high TCR element is not used, the heater s resistance may not change enough relative to temperature to be useful. page 6 2015 Minco 360-00129(-) minco.com

Specifications Inputs Power Input 5 80VDC Outputs Heater Output Ambient 25 C 55 C 70 C Current Rating, 60 VDC Supply Current Rating, 80 VDC Supply 10 amps 6.5 amps 3 amps 10 amps 6.5 amps Not recommended For de-rating curve, see Figure 5. Heater Setpoint Range 0.5Ω to 500Ω Pulse Rate 100ms to 60s Communication Optically via Status LED General Resistance/Temperature Setpoint Resolution 1 milliohm Resistance Measurement Accuracy +/-3%: up to 55 C and at least 0.25 amp load. +/-4%: up to 70 C and at least 0.5 amp load. Dimensions 1.50"L x 1.00"W x 1.00"D (3.81cm L x 2.54cm W x 2.54cm D). Weight Approximately 0.7 oz (20 g) Environmental Operating temperature: -25 to 70 C (-13 to 158 F) @ 90% relative humidity, non-condensing Storage temperature: -40 to 85 C (-40 to 185 F) @ 90% relative humidity, non-condensing Construction Epoxy potted polycarbonate case with one off-center mounting hole. Mounting Mounting hole for #6 screw or #8 thread-forming screw page 7 2015 Minco 360-00129(-) minco.com

12 Rated DC Switching Current 10 8 6 4 2 60 VDC 80 VDC 0-25 -15-5 5 15 25 35 45 55 65 Ambient Temperature ( C) Figure 5 Glossary LED Term Measurement Pulse Pulse Heating SSR TCR USB Definition Light Emitting Diode: A solid state device that converts electricity directly into light. The momentary application of heater power that is used only to measure heater resistance. Heating that occurs not due to the request for heat, but due to the heater being energized momentarily to check its temperature. Solid State Relay: A type of relay without mechanical contacts constructed from solid state components. Temperature Coefficient of Resistance: The relationship between the temperature and resistance of a heater. Universal Serial Bus: A common computer interface on computers for interfacing to various peripherals. page 8 2015 Minco 360-00129(-) minco.com