Preparing the Cabinet

Refrigerators. Technical Manual and Replacement Parts List FORM NO REV H MODEL SKTTR7FW MODEL SKC1220W

DIRECT DRAW BEER COOLERS Installation, Operation and Maintenance Instructions

Technical Manual and Replacement Parts List. f Real Freezers

INSTALLATION AND OPERATION INSTRUCTIONS CONCESSIONAIRE PORTABLE DISPENSERS MODEL NOS.

Operation Manual and Parts Directory

BOTTLE COOLERS SLIDE TOP INSTALLATION AND OPERATION INSTRUCTION MANUAL MODEL SERIES BC24- BC36- BC48- BC72- BC96-

BACK BAR REFRIGERATION Installation, Operation and Maintenance Instructions

Installation & Operation Manual

IMPORTANT PLEASE RETAIN FOR YOUR RECORDS

INSTALLATION and OPERATING. INSTRUCTIONS for. SMZP26 Series. elf-contained Freezers

CABINET PARTS For Models: ET18GKXBW00, ET18GKXBN00 (White) (Almond)

Installation & Operation Manual

MODEL PRODUCT GUIDE

COOLER CART. INSTALLER/ASSEMBLER: Leave these instructions with consumer. CONSUMER: Keep this manual for future reference. MODEL PRODUCT GUIDE

Installation & Operation Manual

CABINET PARTS. REFRIGERATOR For Models: GR2SHKXKQ00, GR2SHKXKT00, GR2SHKXKB00, GR2SHKXKS00 (White) (Biscuit) (Black) (Stainless Steel)

Installation & Operation Manual

Installation & Operation Manual

CABINET PARTS REFRIGERATOR. For Models:ET21PKXGW03, ET21PKXGT03 (White) (Biscuit) Part No Litho In U.S.A. (cre) 1

ET14JKXAW01, ET14JKXAN01, ET14JKYAW01, ET14JKYAN01

Installation & Operation Manual

CABINET PARTS For Model: IST (White)

Glass Door Merchandiser. Model RM-45-SD

Technical Manual and Replacement Parts List. Mobile Freezer

SERIES NAV S Display Merchandisers

GCG-10. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-10-N33EB G-10-N33EB UPRIGHT COOLER

REFRIGERATOR MODELS: WRT138TFYW00 (White) WRT138TFYB00 (Black) WRT138TFYS00 (Stainless Steel)

Installation & Operations Manual for. BMG-HGP Model Bottom Mounted Full-Length Swing Glass Door Refrigerator Merchandisers. 4/17 Rev.

Installation & Operation Manual

Operation Manual and Parts Directory

Installation & Operations Manual for R-290 SERIES. BMG-HGP Model Bottom Mounted Full-Length Swing Glass Door Refrigerator Merchandisers 2/

CABINET PARTS For Models: KBRS22KGWH0, KBRS22KGAL0, KBRS22KGBL0 (White) (Almond) (Black)

CABINET PARTS For Models: GT2SHMXMS04 (Stainless Steel)

Operation Manual and Parts Directory

CABINET PARTS For Models: ET21DKXDW02, ET21DKXDN02, ET21DKXDB02 (White) (Almond) (Black)

CABINET PARTS REFRIGERATOR. For Models: 8ET1FTKXKT00 (Biscuit) Litho In U.S.A. (mdg) 1. Part No

CABINET PARTS REFRIGERATOR. For Models: GT2SHMXMS01 (Stainless Steel) Litho In U.S.A. (ebk) 1. Part No

ICE CREAM TOPPING CABINETS REFRIGERATOR or FREEZER Installation, Operation and Maintenance Instructions

Installation & Operation Manual

User Manual. Commercial School Milk Cooler User s Manual. Commercial School Milk Coolers: MC34, MC49, MC58

CABINET PARTS For Model: IRT (White)

Glass Door Merchandiser. Model RM-49

REFRIGERATOR MODELS: WRT111SFAW00 (White) WRT111SFAB00 (Black) WRT111SFAF00 (Satina) 11/25/ Whirlpool Corporation Part No. W Rev.

UNDERCOUNTER REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

CABINET PARTS. For Models: GS5SHAXNQ02, GS5SHAXNT02, GS5SHAXNB02, GS5SHAXNS02, GS5SHAXNL02 (White) (Biscuit) (Black) (Stainless Steel) (Stainless VCM)

BMG-HGP & BMG-SLP Model Bottom Mounted Full-Length Glass Door Refrigerator Merchandisers

CABINET PARTS For Models: ET21MMXJW01, ET21MMXJT01 (White) (Biscuit)

Glass Door Merchandiser Refrigerator and Freezer

CABINET PARTS REFRIGERATOR

REPAIR PARTS LIST REFRIGERATOR. Model No.(s) (White) (Stainless Steel) (Silver on Black) 106.

Stainless Steel. Care and Cleaning. Mott Manufacturing Limited PO Box 1120 Brantford, Ontario N3T 5T3 Canada

Glass Door Merchandiser

IMPORTANT INFORMATION. for SPE SERIES

GCG-9. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-9-N13EB G-9-N13EB GCG-9-B13EB UPRIGHT COOLER

REF Series Undercounter Refrigerator

CABINET PARTS Printed In U.S.A. (rrm) Part No. W Rev.A REFRIGERATOR

REPAIR PARTS LIST REFRIGERATOR

Installation and Operations Manual for HORIZONTAL DISPLAY MERCHANDISERS

COUNTER TOP REFRIGERATION MODEL SERIES HUBM-2RB/HUBM-2FB/HUBM-3.5RB/HUBM-3.5FB HUBM-2R/HUBM-2F/HUBM-3.5R/HUBM-3.5F

GENERAL LABORATORY REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

CABINET PARTS. For Models: KSRT25CRWH00, KSRT25CRBT00, KSRT25CRBL00, KSRT25CRSS00 (White) (Biscuit) (Black) (Stainless Steel)

CHEF BASE CABINETS Installation, Operation and Maintenance Instructions

WCPT-3 and WCPT-4. Effective Date: 2017 IMPORTANT INFORMATION READ BEFORE USE. Drop-in Display Cases

REPAIR PARTS LIST. Model Nos (White On White) (Bisque) (Black) (Graphite) REFRIGERATOR

CC-2222C-PL, CC-2222C-PRL, CC-2222C-PR-2, CC-2222C-PL-2,

CABINET PARTS For Model: ED5GTGXNQ14, ED5GTGXNB14 (White) (Black)

REFRIGERATED PREP TABLES Installation, Operation and Maintenance Instructions

TOP MOUNT REFRIGERATOR MODELS: WRT106TFDW01 (White) WRT106TFDB01 (Black) WRT106TFDT01 (Biscuit)

Solid Door Top Mount Reach-In Freezer

Installation & Operation Manual

CABINET PARTS Printed In U.S.A. (mat) Part No. W Rev. B

Operation Manual and Parts Directory

CABINET PARTS For Models: ET21GKXGW00, ET21GKXGN00 (White) (Almond)

CABINET PARTS For Models: 7GS2SHEXPQ03, 7GS2SHEXPL03 (White) (Stainless VCM) REFRIGERATOR

ref. com Owner s Manual for models: A Step Above the Standard Thank you for choosing EVEREST

REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

Installation & Operations Manual

Model:WHS-109FB1/WHS-109FW1/WHS-109FSS1

User Manual / Installation Instructions

CHEF BASE CABINETS Installation, Operation and Maintenance Instructions

CABINET PARTS For Models: W8RXNGMWB02, W8RXNGMWS02, W8RXNGMWL02 (Black) (Stainless Steel) (Satina)

InstructIon Manual KrEs EQuIPMEnt stands

Installation & Service Manual

Front Roller (2) Screw Roller (Rear) (2) Screw Clip, Grille Screw Shim

CABINET PARTS. For Models: GR2SHWXPQ00, GR2SHWXPT00, GR2SHWXPB00, GR2SHWXPS00, GR2SHWXPL00 (White) (Biscuit) (Black) (Stainless) (Stainless VCM)

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

WARMING AND MERCHANDISING CABINET

Transcription:

INSTALLATION AND OPERATION INSTRUCTIONS CUSTOM BACK BAR CABINET SELF CONTAINED AND REMOTE MODEL NOS. BS Series BR Series BS Series BR Series IMPORTANT INFORMATION Fill out the enclosed warranty card and mail to the Perlick Corporation to register the warranty. If the card is not returned, the warranty period will begin from the date the equipment is shipped from the factory. This manual has been prepared to assist you in the installation of your Cabinet and to acquaint you with its operation and maintenance. We dedicate considerable time to ensure that our products provide the highest level of customer satisfaction. If service is required, your dealer can provide you with a list of qualified service agents. For your own protection, never return merchandise for credit without our approval. We thank you for selecting a Perlick product and assure you of our continuing interest in your satisfaction. Table of Contents PREPARING THE CABINET Specifications...2,3 List of Included Parts...4 Tools Required...4 Plumbing...4 Electrical...4 Uncrating and Inspection...4 Placing the Cabinet...4 Leveling the Cabinet...4 Installing Casters or Legs...4 Installing the Base Plate...4 Refrigeration and Temperature Control...5 Cleaning the Cabinet...5 Cleaning Stainless Steel...5 Replacement Parts...6 Reversing Door Hinge...7 Wiring Diagram...8 WARNING: When lifting, the full weight of the cabinet must be supported. Lift from the cabinet base and not from the top. Improper lifting can result in severe damage to the cabinet. 8300 West Good Hope Road Milwaukee, WI 53223 Phone 414-353-7060 Fax 414-353-7069 Toll Free 800-558-5592 E-Mail: Perlick@Perlick.com www.perlick.com

Installation and Operating Instructions Sizes and Specifications, Custom Back Bar Cabinets Self Contained MODEL NOS. BS60 BS84 BS108 NUMBER OF S 2 Door 3 Door 4 Door CABINET Length 60 (1524) 84 (2134) 108 (2743) DIMENSIONS Depth 24 3 /4 (629) 24 3 /4 (629) 24 3 /4 (629) (mm) Height 34 1 /2 (876) 34 1 /2 (876) 34 1 /2 (876) CASE CAPACITY (based on 12oz. Export bottle) 12.9 20.4 27.7 CONDENSING UNIT H.P. 1 /4 1 /3 1 /3 RUNNING LOAD AMPS 6.3 8.1 8.3 Ship Wt. Lbs. (kg.) 380 (172) 490 (222) 630 (286) INTERIOR Door sill: High strength polyethylene. Door pan and ceiling: High strength polystyrene. Floor pan and Walls: Stainless steel. Includes pilasters, (2) vinyl coated shelves and floor rack per door, and interior lights. EXTERIOR: Front, back, top and sides stainless steel. Bottom galvanized steel. HINGING Stainless steel hinges with standard locations as illustrated. For special hinging specify hinge locations starting from left to right. Field reversible. HARDWARE REFRIGERATION Door handles: Black vinyl with chrome ends. Lock finish: chrome R-134A capillary tube-type. Aluminum fin and copper tube evaporator, epoxy coated coil. Adjustable temperature control. Self-defrosting. Pull-out condensing unit for service and cleaning. Compressor left, standard. ELECTRICAL 115V, 60Hz., 1 phase AC. Furnished with 3-prong, 6 foot NEMA5-15 PC cord. Contact Perlick for other voltage/ frequency requirements. PLUMBING None required. Condensate evaporates automatically. INSULATION Foamed-in-place polyurethane, 2 walls, 1 1 / 2 top. OPTIONAL Leg set Compressor right Door finishes ACCESSORIES & Tapping kit Brass hardware Black vinyl coated MODIFICATIONS Laminated top Caster sets Stainless steel Laminated ends Base plates Customers choice of laminate Laminated grille Floor access kit Prepared for field lamination Glass door with black vinyl coated frame Glass door with stainless steel frame Glass door with laminated frame 6 3/16 [157] 12 [305] 5 1/8 [130] 108 [2743] 4 84 [2134] 3 60 [1524] 2 92 [2337] 4 68 [1727] 3 44 [1118] 2 6 5/16 [161] NOTE B 4 1/4 [107] 31 1/4 [794] HEIGHT 6 3/8 [163] 24 3/4 [629] 7 3/4 [197] 7 3/16 [182] OPTIONAL FLOOR ACCESS KIT 2 23 1/2 [597] 19 7/8 [505] OPENING R23 1/2 18 3/4 [476] BACK LINER TO INSIDE OF SILL 27 7/16 [697] OPENING NOTE A: 3/4 NPT DRAIN EXIT NOTE B: 1 DRAIN ACCESS 4 3/16 [106] 22 3/4 [578] 1 1/8 [29] 34 1/2 [876] NOTE A 2

Installation and Operating Instructions Sizes and Specifications, Custom Back Bar Cabinets Remote MODEL NOS. BR48 BR72 BR96 NUMBER OF S 2 Door 3 Door 4 Door CABINET Length 48 (1219) 72 (1829) 96 (2439) DIMENSIONS Depth 24 3 /4 (629) 24 3 /4 (629) 24 3 /4 (629) (mm) Height 34 1 /2 (876) 34 1 /2 (876) 34 1 /2 (876) CASE CAPACITY (based on 12oz. Export bottle) 12.9 20.4 27.7 AMPS.9.9.9 BTU/HR 1800 2200 2600 Ship Wt. Lbs. (kg.) 380 (172) 490 (222) 630 (286) INTERIOR Door sill: High strength polyethylene. Door pan and ceiling: High strength polystyrene. Floor pan: Stainless steel. Includes pilasters, (2) vinyl coated shelves and floor rack per door, and interior lights. EXTERIOR: Front, back, top and sides, stainless steel. Bottom galvanized steel. HINGING Stainless steel hinges with standard locations as illustrated. For special hinging specify hinge locations starting from left to right. Field reversible. HARDWARE Door handles: Black vinyl with chrome ends. Lock finish: chrome REFRIGERATION Aluminum fin and copper tube evaporator, epoxy coated coil. ELECTRICAL 115V, 60Hz., 1 phase AC. Contact Perlick for other voltage/ frequency requirements. PLUMBING Independent floor drain or condensate evap. pan is req d. Optional 2 1 / 8 I.D. floor access kit-left rear corner. INSULATION Foamed-in-place polyurethane, 2 walls, 1 1 / 2 top. OPTIONAL Leg set Brass hardware Door finishes ACCESSORIES & Tapping kit Caster sets Black vinyl coated MODIFICATIONS Laminated top Base plates Stainless steel Laminated ends Floor access kit Customers choice of laminate Prepared for field lamination Glass door with black vinyl coated frame Glass door with stainless steel frame Glass door with laminated frame 6-3/16 [157] OPTIONAL FLOOR ACCESS KIT 2 96 [2439] 4 72 [1829] 3 48 [1219] 2 92 [2337] 4 68 [1727] 3 44 [1118] 2 5-1/8 [130] 23-1/2 [597] 19 7/8 [505] OPENING R23-1/2 6-5/16 [161] 4-1/2 [107] 18-3/4 [476] BACK LINER TO INSIDE OF SILL 31-1/4 [794] HEIGHT 6-3/8 [163] 27-7/16 [697] OPENING 22-3/4 [578] 7-3/4 [197] 3-7/16 [87] NOTE A 3/4 NPT DRAIN EXIT NOTE B 1 NPS DRAIN ACCESS 24-3/4 [629] 4-3/16 [106] 7-3/16 [182] 34 1/2 [876] 1-1/8 [29] REFRIGERATION & ELECTRICAL ACCESS RIGHT OR LEFT NOTE A 3

Preparing the Cabinet for Use Parts List (2) Shelves plus (1) Floor Rack-per door. Shelf Clips. Suggested Tools #2 Phillips Screwdriver. 10 Crescent Wrench. 9 / 16 Allen Wrench. 5 / 16 and 3 / 8 Hex Socket. Power Drill or Driver. Plumbing No plumbing required. Condensate from the cooling coil is automatically evaporated through a condensate pan located in the side condensing unit compartment. Unit can be plumbed with a floor drain out rear right corner 3 4 NPT thread or bottom right 1 NPS thread connection out side or bottom. Both drains are plugged and can be removed if needed. Electrical The cabinet must be connected to a separately fused power source (see electrical specification plate) and grounded in accordance with National and Local Electrical Codes. Caution: Do not attempt to operate the equipment on any other power source than that listed on the Electrical Specification plate. Uncrating and Inspection Remove all crating material before operating. Carefully inspect cabinet for hidden damage. If damage is discovered, file your claim immediately with the transportation company. Perlick is not responsible for damage in transit. Installing Casters or Legs (Optional) Attach four casters to the cabinet bottom; rigid casters at the rear and swivel casters on the front. Use the supplied 1 / 4-20 x 3 / 4 hex head self-tapping machine screws. Placing the Cabinet Push the cabinet into place using rollers when necessary. Important: Proper air flow around the condensing unit is necessary for efficient operation. Never obstruct the air flow in and out of the condensing unit. For sanitation purposes, it may be necessary to seal the base of the cabinet to the floor. This can be accomplished by laying a bead of silicone sealant between the base of the cabinet and the floor as shown by the figure at below. CABINET BEAD SILICON SEALER (RTV) FLOOR Leveling the Cabinet When the cabinet is in place, check installation with carpenter s level. When level front to back and left to right, accumulated water will drain out of cabinet evaporator drain. Installing Base Plate (Optional) Attach brackets to cabinet bottom in holes provided. Attach base plate to brackets. (See separate instructions, provided with kit). When returning cabinet to upright position, be careful not to bend brackets. WARNING! To avoid compressor damage,after returning cabinet to an upright position, let unit stand for 24 hours before plugging it in and running the unit. 4

General Information Refrigeration and Temperature Control The Single Door Cooler cabinet is equipped with a heavy-duty refrigeration system designed to automatically maintain a storage temperature of 36-41 degrees F. The control is factory set at 38 degrees F. COLDER 2 3 1 Adjusting the temperature 4 OFF The temperature control is inside the cabinet on the left-hand side of the evaporator fan panel assembly. You will need a screwdriver to turn the adjusting screw. Make small adjustments until the desired temperature is achieved. Colder Temperatures: Turn the adjusting screw clockwise (to the right). Warmer Temperatures: Turn the adjusting screw counterclockwise (to the left). Temperature Control OFF : Turn the adjusting screw completely counterclockwise to the O position until a click is noted. 5 COLD 6 The condenser fan motor turns off and on with the compressor. The evaporator fan motor is on all the time. NOTE: Cabinet Temperatures lower than 34 will not allow for proper defrosting of the evaporator coil. If defrosting is necessary, turn the control knob to the OFF position until coil is defrosted. Cleaning the Cabinet Use a mild detergent and water to clean the inside and outside of the cabinet. Dry thoroughly. Never use a scouring pad or abrasive cleanser. NOTE: An industrial strength, commercial cleaner can be used to clean the outside of painted cabinets. Cleaning the Condenser Use a long handled, stiff brush to clean the dirt from the front surface of the condenser. Keeping the condenser free from dust and dirt will ensure efficient operation. CAUTION: Do not bend the fins while brushing the front of the condenser. Condenser The condenser (located behind the front grille cover) should be inspected every 30 days and cleaned, if necessary. Failure to keep the condenser clean will cause a loss in condensing unit efficiency. Recommended Cleaning Agents JOB CLEANING AGENT* COMMENTS Routine Cleaning Soap, ammonia, detergent Apply with sponge or cloth. Can be used on all finishes. Fingerprints and smears Areal 20, Lac-O-Nu, Lumin Wash, Provides barrier film to minimize O Cedar Cream Polish fingerprints. Can be used on all finishes. Stubborn stains and Allchem Concentrated Cleaner, Rub lightly, using dry or damp Discolorations Samae, Twinkle, Zud Restoro, cloth in the direction of polish Grade F or FFF Italian Pumice, lines on the stainless steel. Whiting or Talc, Liquid Nu Steel, Copper s or Revere Stainless Steel Cleaner, Lumin Cleaner, Sta-Clean, Cameo Copper Cleaner, Allen Polish Highlite, Penny-Brite, Copper Brite * Use of propriety names is intended only to indicate a type of cleaner and does not constitute an endorsement.omission of any proprietary cleaner does not imply its inadequacy. All products should be used in strict accordance with instructions on the package. NOTE: Do Not Use Steel Wool or Scouring Pads to clean stainless steel. 5

Replacement Parts Custom Back Bar Cabinets MODEL NOS. BS60 BS84 BS108 BR48 BR72 BR96 Condensing Units (BS Only) Condensing unit 115 volt, 60 hz. C22647 C22646 C22646 Condensing unit 515301063 515301062 515301062 Compressor 513200314 513200003 513200003 Fan motor assembly 215315009 215315009 215315009 Condenser coil 15352019 15352019 15352019 Terminal board 219101538 219101538 219101538 Overload protector MRT20AGK5590 MRT22AGK5590 MRT22AGK5590 Relay 21351619 21351619 21351619 Capacitor 13556529 13556532 13556532 Evaproator Assembly Self Contained (BS) complete 65555-1 65555-2 65555-2 Remote (BR) complete 65555-1R 65555-2R 65555-2R Evaporator coil (BS) & (BR) C17511-1EP C17511-2EP C17511-2EP Liquid & Suction line (BS) 65084 65085 65085 Fan blade 57699 57699 57699 Fan motor C15239A C15239A C15239A Evaporator fan guard 65557 65557 65557 Temperature control 61283 61283 61283 Bulb clamp C6634 C6634 C6634 Wire harness, compressor bottom 65560 65560 65560 Wire harness, evaporator 65561 65561 65561 Wire harness, light jumper 65538 65539 65540 Wire harness, mullion heater 65571 65572 65573 Light bulb 63821 63821 63821 Light bulb guard 65525 65525 65525 Light socket 63484 63484 63484 Light switch 65535 65535 65535 Lock 63762 63762 36762 Space, lock 63761-1 63761-1 63761-1 Lock rail 65432-24SS or 65432-24 65432-24SS or 65432-24 65432-24SS or 65432-24 Grille rail 65432-12SS or 65432-12 65432-12SS or 65432-12 65432-12SS or 65432-12 Condenser pan 65565-1 65565-1 65565-1 Condenser end panel 66215-1SS 66215-1SS 66215-1SS Grille, black 66210-12 66210-12SS 66210-12SS Grille, SS 66210-12SS 66210-12 66210-12 Condenser housing back 65435-12SS 65435-12SS 65435-12SS Evaporator, liquid & suction line cover 65576-1L 65576-2L 65576-3L Evaporator pan 65526-1 65526-2 65526-2 Door sill 65500-1 65500-1 65500-1 Door handle bracket 65189-1 65189-1 65189-1 Door handle C31409-1 C31409-1 C31409-1 Door gasket 66237-4 66237-4 66237-4 Cabinet hinge 65436-LBRT 65436-LBRT 65436-LBRT Cabinet hinge 65436-LBRB 65436-LBRB 65436-LBRB Hinge pin 63679-1 63679-1 63679-1 Hinge assembly, cabinet left side 65505L 65505L 65505L Hinge assembly, cabinet right side 65505R 65505R 65505R End shelf kit 57928 57928 57928 Center shelf kit 57929 57929 Left or right shelf 62307-2 62307-2 62307-2 Center shelf 62308-2 62308-2 Vertical partition 61830-1 61830-1 61830-1 Pilaster strip C19271-1 C19271-1 C19271-1 Shelf clip C15875 C15875 C15875 *Replacement door RD-NL2 RD-NL2 RD-NL2 *Contact Perlick Milwaukee for complete door replacement. Cabinet serial no. required. 6

Reversing Door Hinge Tools Required Phillips Screwdriver. #4 Allen Wrench. Flathead Screwdriver or Putty Knife Right Hinged Door (as shipped from factory) STEP 9: Re-insert top hinge pin. STEP 10: Re-assemble lock rail from STEP #3 Bottom Hinge Bracket Operations to Perform on Door Top Hinge Bracket Step #14 Operations to Perform on Cabinet STEP 1: Remove bottom hinge pin from assembly. STEP 2: Carefully lift and tilt out door assembly from the unit and set aside. Step #12 Step #11 Step #13 STEP 3: Remove lock rail from cabinet, requires removal of four screws. STEP 4: Remove top hinge pin. Remove top and bottom hinge brackets from the unit. STEP 5: Remove hinge bushing from bottom hinge bracket and assemble to top hinge bracket. STEP 6: Taking care not to scratch the surface, remove hole plugs from the left hinge holes. STEP 7: Insert hole plugs into vacant right hinge holes Remove these screws Top Hinge Bracket Hinge Bushing Bottom Hinge Bracket Step #6 Step #7 STEP 8: Re-assemble hinge brackets to unit. Bottom right bracket is assembled as the top left bracket. Top right bracket is assembled as the bottom left bracket. STEP 11: Remove bottom door hinge bracket from door assembly and remove door hinge bushing from bracket. Re-assemble door hinge bracket to previous position, without bushing. STEP 12: Remove top door hinge bracket from door assembly and assemble door hinge bushing from STEP 11 to bracket. Re-assemble door hinge bracket to previous position with bushing attached. STEP 13: Remove handle and reposition in other set of pre-drilled mounting holes directly underneath.. STEP 14: Remove lock retainer and install on opposite end of door.. STEP 15: What was the door top is now the door bottom. Carefully lift the door onto the hinge brackets of the cabinet. The two hinge bushings should meet. reinsert the bottom hinge pin to complete the door switching operation. 7

Wiring Diagram Custom Back Bar Cabinets [2] [3] [4] MULLION HEATER MULLION HEATER MULLION HEATER BR Series Remote 2, 3 and 4 Door RED LIGHT SWITCH LIGHT LIGHT LIGHT LIGHT EVAPORATOR FAN EVAPORATOR FAN THESE WIRES CAPPED IN SINGLE CABINET INSTALLATIONS EVAPORATOR HOUSING GROUND WIRE RED CABINET JUNCTION BOX NOTE: FIELD WIRING FROM CABINET JUNCTION BOX TO CONDENSING UNIT MUST COMPLY WITH ALL LOCAL AND NATIONAL ELECTRICAL CODES. GREEN CONDENSING UNIT GREEN POWER CONNECTION JUNCTION BOX FIELD INSTALLED [2] [3] [4] MULLION HEATER MULLION HEATER MULLION HEATER PRESSURE SWITCH BS Series Self-Contained 2, 3 and 4 Door EVAPORATOR FAN RED LIGHT SWITCH LIGHT LIGHT LIGHT LIGHT EVAPORATOR FAN THERMOSTAT RED POWER CONNECTION GREEN GREEN CONDENSING UNIT JUNCTION BOX 8300 West Good Hope Road Milwaukee, WI 53223 Phone 414-353-7060 Fax 414-353-7069 Toll Free 800-558-5592 E-Mail: Perlick@Perlick.com www.perlick.com 8