Sensor MSS100 Multi-Sonic

Similar documents
, Temperature Sensor Product Electrical Installation

Series 45 Pumps Fan Drive Control (FDC)

Proportional Valve Group Modules PVSK

PVSK Module with Integrated Diverter Valve and P-Disconnect Function. Tech Note

RS485 MODBUS Module 8AI

SGJ. 80, 120-inch Stroke Range Options. Polycarbonate Enclosure IP67. In Stock for Quick Delivery. General. CANbus Specifications

User Manual Doc.Ref : JA-KNX-UM. JA-KNX Jablotron KNX Interface ELAUSYS JA-KNX. KNX Interface for Jablotron alarm system.

User Manual Doc.Ref : EVO-KNX-UM. EVO-KNX Paradox KNX Interface ELAUSYS EVO-KNX. KNX Interface for Paradox alarm system. User Manual.

HM-4201-RTCM High-Temp Real Time Clock Module

MS4525DO SPECIFICATIONS FEATURES APPLICATIONS

ECO N DATE DESCRIPTION OF CHANGE CHG

KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no )

Series Digital Controller Instruction Sheet

FlameGard 5 UV/IR HART

Light Level Detector, Surface Mount 5754PE. Installation Instructions

IFT-RC150 IntelliFire Touch Remote Control Installation Instructions

DOG2 MEMS SERIES CAN J1939 INCLINOMETER

Isolated Thermocouple Module

OEM REFRIGERANT GAS SENSORS for Leak Detection & Measurement

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick

Issue C CAUTION

TD80 LEVEL GAUGING & OVERFILL PREVENTION SYSTEM PRODUCT MANUAL SUPPLEMENT. TPM 005 Revision 0.0

SKJ. Specifications. Stroke Range Options 250 inches (6.4 m), 400 inches (10.2 m)

Long Range Radio Alarm Transmitter

Long Range Radio Alarm Transmitter

USER MANUAL FOR OPERATING SYSTEM

MODBUS / BACnet Adapter Installation Instructions

MAKING MODERN LIVING POSSIBLE. Installation Guide. ECtemp 550. Electronic Intelligent Thermostat.

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

FlameGard 5 MSIR HART

US$ 350 for a single warranty claim

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

Mark 25 Ultrapure Water Conductivity Analyzer

ATEX. Tough controls for tough environments. ia.danfoss.com. Brochure Controls. Danfoss controls - designed and approved for hazardous areas

NGC-40 Bridge. Modbus Overview. Raychem-AR-H58862-NGC40BridgeModbusOV-EN-1805 nvent.com 1

HM-4201-RTCM High-Temp Real Time Clock Module

Installation Instructions for the

34% A temperature sensor overview Cut back on system costs Upgrade to the right technology. cost reduction

FL500 Modbus Communication Operating Manual. Order No.: /00. MSAsafety.com

General Purpose IO Technical Manual

Public Safety DAS Annunciator Panel

FTP-1000 Touchpad/Display Installation Manual

P2267 NETWORK INTERFACE

HBPS PRESSURE SENSOR For analogue pressure measurement of refrigerants

89BSD Digital Output

200 SERIES ADVANCED PHOTO/THERMAL/IR DETECTOR PRODUCT SPECIFICATION

ENGINE MONITOR VOTT MODEL: YEAR WARRANTY

OWNERS MANUAL OPERATION GUIDE

C-Bus Four Channel General Input Unit Installation Instructions

mtc001 Thermocouple Converter

Meridian wiredhart. HART Field Device Specification Goldmine Rd. Monroe, NC USA

Netbiter Tank Sensor

SERIES PSE-690 INSTALLATION & OPERATION MANUAL IMPORTANT: PSE-690 REMOTE STROBE POWER SUPPLY

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

HPM Series. Issue D. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

Operating instructions

FOT-100. Fiber Optic Temperature Sensor User s Manual P/N: I3A-110

HPM Series. Issue C. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

Analog Input Module IC670ALG630

HPM Series. Issue B. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

TESS WIRELESS SENSOR TAG DEMO V1.1

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Database for CTS6000 MODBUS

WIO500 and WIOI500 Water in oil sensor

DE20 INSTRUCTION MANUAL

MEAS PICTAIL PLUS FOR MICROCHIP EXPLORER 16

SonoSelect and SonoSafe energy meters

RC-122BZ Two Stage Heat/Cool 2 Stage Heat / 2 Stage Cool Thermostat Installation Instructions

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

Fan Coil Thermostat Controller Specification and Installation Instructions. Model TFHB24F3XYZ1 with External Humidity Sensor and BACnet Communication

PACSystems* RX3i. Thermocouple Input Module, 12 Channels, IC695ALG412. GFK-2578B October 2011

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

2CDC D Product manual ABB i-bus KNX LGS/A 1.2 Air Quality Sensor with RTC

Model A-5. Low Range Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES

/9308 External Battery Chargers Installation Instructions

Module Features are-configurable, no module jumpers to set

User Guide OI/FEX100HART EN Rev. A. WaterMaster FEX100 HART Field Device Specification

Danfoss the world s biggest producer of radiator thermostats

85 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Compod. Instruction Manual IM-COMPOD Revision: C.1, November 2010

AN FXPS7xxx series pressure sensor self-test features. Document information

Analog Room Pressure Monitor RPC Series

154BC SPECIFICATIONS. Please refer to the 154N uncompensated and constant voltage datasheets for more information on different features of the 154.

Burner control unit BCU 370

4100U City and Relay Cards Installation Instructions

NGC-UIT2 MODBUS PROTOCOL INTERFACE MAPPING FOR NGC-30 SYSTEMS. Firmware versions up to V2.0.X

Easy Dose Chemical Injection and Dispensing System DEMA Engineering Company

Honeywell Zephyr Digital Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

Remote Vacuum Sensor and Variable Speed Vacuum Pump Control Manual. Version Date - June Part Number

Infrared Thermometer

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

PROFIBUS-PA Display RID 261 PROFIBUS-PA

Ethernet General Purpose

IMM TECHNOLOGY YOUR SOLAR PLANT AT YOUR FINGERTIPS WHAT IS IMM? WHY IMM? PL EN V1.1

Transportation Attitude Reference System (TARS Series) Ruggedized Inertial Measurement Unit (IMU) Issue 2. Datasheet

RK Carbon Monoxide Transmitter Operator s Manual

MSP100 Pressure Transducer

Model 144H. Product Data Sheet , Rev DB February Content

Weather compensated flow temperature control of heating and boiler systems

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Transcription:

Technical Information Sensor MSS100 Multi-Sonic powersolutions.danfoss.com

Revision history Table of revisions Date Changed Rev November 2017 Minor update 0101 November 2013 Rebranded in InDesign, wait until next update before publishing to CMS; LED control summary, CAN message to sensor AB February 2013 First edition AA 2 Danfoss November 2017 L1230958 BC00000216en-US0101

Contents General Information Product Installation Sensor Configuration Product Overview...4 Features and Options...4 User liability and safety statements...4 OEM responsibility...4 Theory of Operation... 5 Ordering Information...5 Dimensions and Key Features...6 Mechanical Installation...6 Connector Pin Assignments... 7 Machine wiring guidelines...7 Machine welding guidelines... 8 Using the Sensor s Configuration Input Pin to Set the Source Address... 9 Controller Area Network (CAN) Message Protocols Sensor Data and Status...10 LED Control Summary... 10 CAN Message to Sensor...10 Sensor Control Example... 11 Request to Sensor to Transmit Data 11 bit ID... 11 Return sensor Data/Status to Controller 11 bit ID... 11 Broadcast Message to Sensor LEDs 11 bit ID...11 Configure Sensor Work Mode 11 bit ID...12 Configure Sensor On/OFF 11 bit ID... 12 Request to Sensor to Transmit Data 29 bit ID... 12 Return Sensor Data/Status to Controller 29 bit ID...12 Broadcast Message to Sensor LEDs 29 bit ID...12 Configure Sensor On/OFF 29 bit ID... 13 Configure Sensor Work Mode 29 bit ID...13 Specifications Notes Electrical... 14 Environmental...14 Mechanical... 14 Danfoss November 2017 L1230958 BC00000216en-US0101 3

General Information Product Overview The MSS100 Multi-Sonic grade sensor is designed to be highly versatile with regards to use and connectivity. It s equipped with four ultra sonic sensors operating at an optimized frequency resulting in high precision. The large span of the four sensors gives the MSS100 excellent abilities for string line sensing. The sensor is equipped with LED panels on two sides. The active panel facing the operator and his crew gives a visual indication showing how the current mat thickness is following the set reference. Switching between string line mode and ground mode is achieved by pressing the Mode button or by digital communication. When in string line mode an LED indicator shows if the sensor is working within or is about to exceed it s operating range. The MSS100 features a reference bail for optimum temperature and wind compensation. The bail is made of spring steel and will return to it s original shape despite significant bending. The reference bail can easily be removed when the sensor is not in use. Sensor communications is maintained digitally via CAN bus. Features and Options Ceramic based ultrasonic sensing technology Multiple sensors PLUS+1 Compliant Capable of string line or ground sensing String line sensing range: 270 to 650 mm Ground sensing range: 250 to 900 mm CAN 2.0 B compliant Supports 11 bit and 29 bit message ID 1 mm resolution Temperature bail for temperature and wind compensation LED grade indicators for high/on/low operator feedback User liability and safety statements OEM responsibility The OEM of a machine or vehicle in which Danfoss products are installed has the full responsibility for all consequences that might occur. Danfoss has no responsibility for any consequences, direct or indirect, caused by failures or malfunctions. Danfoss has no responsibility for any accidents caused by incorrectly mounted or maintained equipment. Danfoss does not assume any responsibility for Danfoss products being incorrectly applied or the system being programmed in a manner that jeopardizes safety. All safety critical systems shall include an emergency stop to switch off the main supply voltage for the outputs of the electronic control system. All safety critical components shall be installed in such a way that the main supply voltage can be switched off at any time. The emergency stop must be easily accessible to the operator. 4 Danfoss November 2017 L1230958 BC00000216en-US0101

M OD E Technical Information General Information Theory of Operation MSS100 Ranges for String Line and Ground Sensing mm [in] 0 [0 in] 0 [0 in] 150 [5.91] 150 [5.91] 250 [9.84] 250 [9.84] 350 [13.78] 350 [13.78] 450 [17.72] 450 [17.72] 550 [21.65] 550 [21.65] 650 [25.59] String Line Sensing Mode 650 [25.59] 750 [29.53] 850 [33.46] 900 [35.43] Ground Sensing Mode P200 102 Switch between string line and ground sensing mode by pushing Mode button or through set work mode CAN message. Ordering Information Product Danfoss part number MSS100 11103282 CG150 CAN/USB Gateway 10104136 Mating connector 11031032 PLUS+1 GUIDE single user license 10101000 Danfoss November 2017 L1230958 BC00000216en-US0101 5

Multiple Ceramic Senso Technical Information Product Installation Dimensions and Key Features 257.5 [10.14] 109.5 [4.31] 63.0 [2.48] 6 Pin Connector Mounting Puck M OD E 63.0 [2.48] Grade Indicators Temperature Bail C Caution This device is not field serviceable. Opening the device housing will void the warranty. Mechanical Installation Install by either using the mounting puck or inserting a 5/8 rod through the center of the mounting puck with two set screws. Cup Mounting Puck 5/8 Rod Mounting Puck P200 105 6 Danfoss November 2017 L1230958 BC00000216en-US0101

Product Installation Connector Pin Assignments 6 Pin Connector (Configuration resistor between pins E and B) F A E B D C P200 106 Connector Pin A B C D E F Controller function Power Ground CAN Hi CAN Lo Config Not used Use care when wiring mating connector. Above pinouts are for device pins. Machine wiring guidelines W Warning Unintended movement of the machine or mechanism may cause injury to the technician or bystanders. Improperly protected power input lines against over current conditions may cause damage to the hardware. Properly protect all power input lines against over-current conditions. To protect against unintended movement, secure the machine. C Caution Unused pins on mating connectors may cause intermittent product performance or premature failure. Plug all pins on mating connectors. Protect wires from mechanical abuse, run wires in flexible metal or plastic conduits. Use 85 C (185 F) wire with abrasion resistant insulation and 105 C (221 F) wire should be considered near hot surfaces. Use a wire size that is appropriate for the module connector. Separate high current wires such as solenoids, lights, alternators or fuel pumps from sensor and other noise-sensitive input wires. Run wires along the inside of, or close to, metal machine surfaces where possible, this simulates a shield which will minimize the effects of EMI/RFI radiation. Do not run wires near sharp metal corners, consider running wires through a grommet when rounding a corner. Do not run wires near hot machine members. Provide strain relief for all wires. Avoid running wires near moving or vibrating components. Avoid long, unsupported wire spans. Ground electronic modules to a dedicated conductor of sufficient size that is connected to the battery (-). Danfoss November 2017 L1230958 BC00000216en-US0101 7

Product Installation Power the sensors and valve drive circuits by their dedicated wired power sources and ground returns. Twist sensor lines about one turn every 10 cm (4 in). Use wire harness anchors that will allow wires to float with respect to the machine rather than rigid anchors. Machine welding guidelines W Warning High voltage from power and signal cables may cause fire or electrical shock, and cause an explosion if flammable gasses or chemicals are present. Disconnect all power and signal cables connected to the electronic component before performing any electrical welding on a machine. The following is recommended when welding on a machine equipped with electronic components: Turn the engine off. Remove electronic components from the machine before any arc welding. Disconnect the negative battery cable from the battery. Do not use electrical components to ground the welder. Clamp the ground cable for the welder to the component that will be welded as close as possible to the weld. 8 Danfoss November 2017 L1230958 BC00000216en-US0101

Sensor Configuration Using the Sensor s Configuration Input Pin to Set the Source Address An external resistor at the cable connection point is used to generate a unique source address for each sensor. The Sensors have a fixed base transmit message identifier from 0x630 (11 bit)/ 0x18FF5209 (29 bit) combined with its Sensor configuration resistor the sensor modifies the base identifier to create the final Sensor transmit identifier. An offset is added to the receive identifier: Offset * 0x1 (11 bit) or Offset * 0x10 (29 bit). CAN IDs Baud rate = 250 kbps 11 bit address 29 bit address, J1939 Transmit ID 0x630 + offset 0x18FF5209 + ( offset * 0x10) Receive ID 0x530 + offset 0x18FF4209 + ( offset * 0x10) Configuration ID Offset Offset Resistor (Ohms) 1 Open 2 0 3 390 4 750 5 1100 6 1500 7 2000 8 2700 9 3300 10 4300 11 5600 12 7500 13 10,000 14 13,000 15 22,000 16 33,000 Configuration resistor must be placed between pins E and B. Danfoss November 2017 L1230958 BC00000216en-US0101 9

Controller Area Network (CAN) Message Protocols Sensor Data and Status Height CAN Message from Sensor: Cyclic and/or Requested Sensor Data Byte Sensor transmit ID: 0x530 + Offset (11 bit) or 0x18FF4209 + (Offset * 0x10) (29 bit) 0 0x01 1 Sensor status Name Bit 1 Bit 0 0 Sensor stale Sensor stale/wrong data Correct data 1 Sensor On/OFF Sensor is switched off Sensor is active (default) 2 3 4 5 6 Reference bail Bail (default) No bail 7 Sensor mode String line mode Ground mode (default) 2 Low byte Elevation data sensor absolute range [LSB = 1 mm] 3 High byte LED Control Summary CAN Controller LED Transmit Message to All Sensors: Broadcast Byte Controller transmit ID: 0x630 (11 bit) or 0x18FF5209 (29 bit), no offset 0 0x01 1 External LED command Hex byte Bit 2 Bit 1 Bit 0 LED description on 0x0 0 0 0 All off 0x1 0 0 1 Up 0x2 0 1 0 On-grade 0x3 0 1 1 Up and on-grade 0x4 1 0 0 Down 0x5 1 0 1 Up and down 0x6 1 1 0 Down and on-grade 0x7 1 1 1 All on 2 Bit 0-3 ON time (0-15) (0 to 750 ms) in 50 ms steps 3 Bit 0-3 OFF time(0-15) (0 to 750 ms) in 50 ms steps 4-7 NA 7 NA CAN Message to Sensor Data Request Byte Controller transmit ID: 0x630 + Offset (11 bit) or 0x18FF5209 + (Offset * 0x10) (29 bit) 0 0x01 1 Low byte Cycle time in ms (if cycle time = 0 only one data message will be sent) 10 Danfoss November 2017 L1230958 BC00000216en-US0101

Controller Area Network (CAN) Message Protocols Data Request (continued) 2 High byte 3-7 NA Command: Sensor On/Off Byte Controller transmit ID: 0x630 + Offset (11-bit) or 0x18FF5209 + (Offset * 0x10) (29 bit) 0 0x02 1 Status unsigned char ; $00 = Sensor active ; $01 = Sensor off 2-7 NA No answer from the sensor. The result will be shown in the next data message in the status flag. Default: Sensor on. Command: Set Work Mode Byte Controller transmit ID: 0x630 + Offset (11 bit) or 0x18FF5209 + (Offset * 0x10) (29 bit) 0 0x03 1 Work mode unsigned char ; $00 = Ground Mode ; $01 = String line mode 2-7 NA No answer from the sensor. The result will be shown in the next data message in the status flag. Default: Ground mode. Sensor Control Example Request to Sensor to Transmit Data 11 bit ID Wait 2 seconds for sensor to initialize from power up before sending request. SA ID offset used. 0631 8 01 14 00 FF FF FF FF FF Request to sensor from controller 0x01 Cycle time in ms LSB 20 ms Cycle time in ms MSB Return sensor Data/Status to Controller 11 bit ID Sensor returns data/status after the receipt of: Request to sensor to transmit Data 11 bit ID. SA ID offset used. 0531 8 01 40 70 01 FF FF FF FF Status and data from sensor to controller 0x01 Status = correct data, sensor is active, bail on Elevation data in mm LSB Elevation data in mm MSB Broadcast Message to Sensor LEDs 11 bit ID No SA ID offset used. If multiple sensors at different IDs are present they receive the same broadcast message. Danfoss November 2017 L1230958 BC00000216en-US0101 11

Controller Area Network (CAN) Message Protocols 0630 8 01 02 0A 0A 0A FF FF FF 271.604 R Broadcast message to sensor from controller 0x01 Sensor LED command LED on time LED off time LED intensity Configure Sensor Work Mode 11 bit ID SA ID offset used. 0631 8 03 00 FF FF FF FF FF FF Configure message to sensor from controller 0x03 sensor work mode type 0 = Ground (default) 1 = String line Configure Sensor On/OFF 11 bit ID SA ID offset used. 0631 8 02 01 FF FF FF FF FF FF Configure message to sensor from controller 0x02 sensor on/off type 0 = sensor off 1 = sensor on (default) Request to Sensor to Transmit Data 29 bit ID Wait 2 seconds for sensor to initialize from power up before sending request. SA ID offset used. 18FF5219 X 8 30 00 00 FF FF FF FF FF Data request sent to sensor from controller 29 bit 0x30 Return Sensor Data/Status to Controller 29 bit ID Sensor returns data/status after the receipt of: Request to sensor to transmit data 29 bit ID. SA ID offset used. 18FF4219 X 8 01 C0 A2 01 00 00 00 00 Status and data sent from sensor to controller 0x01 Status = Correct data, sensor is active, bail on Elevation data in mm LSB Elevation data in mm MSB Sensor Control Example (continued) Broadcast Message to Sensor LEDs 29 bit ID No SA ID offset used. If multiple sensors at different IDs are present they receive the same broadcast message. 18FF5209 X 8 01 07 0A 0A 0A FF FF FF Broadcast message sent to sensor from controller 29 bit 0x01 Sensor LED command LED on time LED off time LED intensity 12 Danfoss November 2017 L1230958 BC00000216en-US0101

Controller Area Network (CAN) Message Protocols Configure Sensor On/OFF 29 bit ID SA ID offset used. 18FF5219 8 02 01 FF FF FF FF FF FF Configure message to sensor from controller 0x02 sensor on/off type 0 = Sensor off 1 = Sensor on (default) Configure Sensor Work Mode 29 bit ID SA ID offset used. 18FF5219 8 03 00 FF FF FF FF FF FF Configure message to sensor from controller 0x03 sensor work mode type 0 = Ground (default) 1 = String line Danfoss November 2017 L1230958 BC00000216en-US0101 13

Specifications Electrical Supply voltage Maximum power consumption 12 to 30 Vdc 250 ma Environmental Operating temperature range -10o C to 70o C (-14 F to 158 F) Storage temperature range -40o C to 85o C (-40 F to 185 F) Mechanical Resolution Temperature compensation Transducer beam width degrees String line sensing range Ground sensing range Weight 1 mm (0.04 in) 165 mm ( 6.50 in) detachable bail 12o ± 2o 270 to 650 mm (10.63 to 25.59 in) 250 to 900 mm (9.84 to 35.43 in) 1400 g (3.09 lbs) 14 Danfoss November 2017 L1230958 BC00000216en-US0101

Notes Danfoss November 2017 L1230958 BC00000216en-US0101 15

Products we offer: Bent Axis Motors Closed Circuit Axial Piston Pumps and Motors Displays Electrohydraulic Power Steering Electrohydraulics Danfoss Power Solutions is a global manufacturer and supplier of high-quality hydraulic and electronic components. We specialize in providing state-of-the-art technology and solutions that excel in the harsh operating conditions of the mobile off-highway market. Building on our extensive applications expertise, we work closely with our customers to ensure exceptional performance for a broad range of off-highway vehicles. We help OEMs around the world speed up system development, reduce costs and bring vehicles to market faster. Danfoss Your Strongest Partner in Mobile Hydraulics. Hydraulic Power Steering Go to www.powersolutions.danfoss.com for further product information. Integrated Systems Wherever off-highway vehicles are at work, so is Danfoss. We offer expert worldwide support for our customers, ensuring the best possible solutions for outstanding performance. And with an extensive network of Global Service Partners, we also provide comprehensive global service for all of our components. Joysticks and Control Handles Microcontrollers and Software Open Circuit Axial Piston Pumps Orbital Motors Please contact the Danfoss Power Solution representative nearest you. PLUS+1 GUIDE Proportional Valves Sensors Steering Transit Mixer Drives Comatrol www.comatrol.com Local address: Turolla www.turollaocg.com Hydro-Gear www.hydro-gear.com Daikin-Sauer-Danfoss www.daikin-sauer-danfoss.com Danfoss Power Solutions (US) Company 2800 East 13th Street Ames, IA 50010, USA Phone: +1 515 239 6000 Danfoss Power Solutions GmbH & Co. OHG Krokamp 35 D-24539 Neumünster, Germany Phone: +49 4321 871 0 Danfoss Power Solutions ApS Nordborgvej 81 DK-6430 Nordborg, Denmark Phone: +45 7488 2222 Danfoss Power Solutions Trading (Shanghai) Co., Ltd. Building #22, No. 1000 Jin Hai Rd Jin Qiao, Pudong New District Shanghai, China 201206 Phone: +86 21 3418 5200 Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. Danfoss November 2017 L1230958 BC00000216en-US0101