Hydroflo Prepackaged Pumping Systems

Similar documents
SECTION PACKAGED HEAT TRANSFER SYSTEM

CTO BOOSTER SPECIFICATION

SECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY

Lift Station Monitoring & Control The process begins here

Custom Pump Controls. The Custom Controls Solution Provider. A New Generation. Complete Management. Page 2

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

Automation and Energy Efficiency of Industrial Refrigeration Systems

Tri-Stack Smart System

Note: The office/work area is not in the scope of the PER. Existing Condition

Wilo CO-Helix Booster Systems. Product Presentation July, 2017

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

Operational Overview and Controls Guide

LMV51 Control. Specifications. Document No. LV February 7, Product Description. Sample Specification

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

Precise Temperature Control; Compact Footprint

LC150 VIEW-AT-A-GLANCE PUMP CONTROL-TELEMETRY UNIT

NQ Series Portable Chillers

Sequence of operation

PUMP CONTROL CENTER (PCC)

SECTION 4000 LIFT STATIONS

Casey Craft

Wet Well Mounted Pump Stations

V1.21: (Required for All Dryers with Static Sampler or Incoming MST Sensor, Good for All Dryers)

Pump Station Appliance

LMR Electric Fire Pump Controllers Features

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Complete packaged and custom solutions for mechanical, plumbing, and industrial systems.

ENGINEERED SYSTEMS CUSTOM DESIGNED AND BUILT DESIGNED FOR YOU CAPABILITIES IDENTIFYING YOUR NEEDS COMMISSIONING YOUR SYSTEM

HEAT TROL ELITE SERIES HWE-Single Stage, HWE-MOV, HWE-Mulit Stage Hot Water Reset Control for Light Commercial and Residential Applications Provides q

Lift Station Level Controller

LMR Electric Fire Pump Controllers Features

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

SPECIFICATIONS - DETAILED PROVISIONS Section Magnetic Flowmeters C O N T E N T S

DemandAire. amaximize Energy Efficiency aincreased Kitchen Comfort acustomizable Systems. Demand Control Kitchen Ventilation System

MYRIAD DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL VERSION 3.7

Operation Manual. Programmable Logic Controller

Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass

Annunciation, Remote Monitoring, Control Industrial Control Panels

CALL FOR TENDER - MUNICIPALITY OF THE DISTRICT OF CLARE LITTLE BROOK, N.S.

CONTROL SYSTEMS Combustion Control Burner Management Control Balance of Plant Equipment Control Supervisory Control and Data Acquisition

SCC Inc. TS Series. Technical Instructions. Document No. TS 5000 February 12, TS CE Combustion Enclosures with LMV3.

SYSTEMS THINKING AND TROUBLESHOOTING

SECTION BUILDING AUTOMATION SYSTEM

Frequently asked questions: Intelligent Transmitter Series

Section UV DISINFECTION SYSTEM Greater Vernon Water Page 1 of 18 TABLE OF CONTENTS

70E Pressure Booster. Bell & Gossett. Bulletin D-215D. Efficient Operation. Easy to Select and Install. Quick Set-up through EZ Start

I/O ZONE 560/583 USERS GUIDE

CELLTROL II BIOREACTOR CONTROL SYSTEM OPERATIONS MANUAL

Transfer Switch Features

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

AccuBrine automated brine maker Technical Specifications

November 11, City of Sparks 215 S. 21 st St. Sparks, NV

opti-visor ultra-efficient chiller plant automation Typical specification

SCC Inc. TS Series. Technical Instructions. Document No. TS 1000 June 25, TS Touchscreen Kits. Description. Touchscreen

PS SERIES PARALLEL RACK SYSTEM GLYCOL CHILLER START UP GUIDE. Master Rack Compressor Sequencer 7/21/2017

PRODUCT REVIEW Honeywell HC900 Hybrid Vacuum Furnace Control System

Transfer Switch Features

Drawing Submittal Package

Outstanding Performance; Application Flexibility

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

TS Series. Technical Instructions. Document No. TS-4000 June 25, TS-CE Combustion Enclosures with LMV5. Description

OPERATING MANUAL Enertronic Control System 2

CPF PRODUCT DESCRIPTION

Connected Control (BCC100)

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

I P. Tough Starters for Tough Environments. Explosion Proof Starter. Ready to Install, Completely Wired and Assembled

SECTION FIRE PUMPS 1.00 PART 1 & GENERAL Description of Work. A. Provide pumps for fire suppression Section Includes

P.C. Simonton & Associates, Inc. Consulting Engineers. Paul C. Simonton

DIESEL Engine Fire Pump Controllers Features

Mission Critical. Fuel Supply Systems

Labkotec Ice Detector

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

Touchscreen & PLC Control System

Drawing Submittal Package

Feature Summary. I. System

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

CPVS PRODUCT DESCRIPTION

Corrigo E. Second generation which contains all applications and languages

Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch

VACUUM BREAKER MEDIUM VOLTAGE AUTOMATIC TRANSFER SWITCHES

K-Controller Brochure.qxp_ Controller Brochure 2/27/17 3:03 PM Page 4 Versa IC Platform

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

C1N & C2N SERIES Fluid heating for light industrial applications


Electric Coils. Blower Coils. Product Information

Central Chillers TS Series

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

CONSTANT PRESSURE CONTROLLER

REMOTELY OPERATED STENCH GAS RELEASE SYSTEM. Front Panel View Remote Activated Stench Gas Release System 240 Volt AC Supply

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Monitoring Solutions

SECTION SANITARY SEWAGE PUMP STATIONS

Transcription:

Hydroflo Prepackaged Pumping Systems Presented to: Presented by: John Curls Jr., P.E. BARNEY S PUMPS INC.

What is it? Hydroflo A Hydroflo Packaged Pumping System provides variable volume at a constant pressure regardless of flow requirements. Why buy it? Availability Quality UL QCZJ listed as an entire assembly Cost Pre-engineering provides cost savings A framework with options Accountability Witness testing at no charge

A Hydroflo System

Hydroflo Applications Potable water Reclaimed water Sewage Seal water system Process water Any application for Quick turnaround Minimized on-site presence Possible elimination of or reduced need for a contractor

Hydroflo Applications

Pump(s) Main Hydroflo Components Jockey/pressure maintenance pump Skid base Pipe and valves Hydraulically-actuated automatic control valve (Cla-Val) Hydropneumatic tank? Depends on system, but VFD s are generally better A tank means a larger footprint Control Panel Instrumentation Other Power Zone Antennae

A Hydroflo System

A Hydroflo System

Hydroflo Pump Types Basically most any type of pump can be used to meet the needs of the application Flow considerations Pressure considerations Space/geometry considerations Special constraints imposed by the application (material, environmental, etc.) Cost considerations

Hydroflo Valves, Pipe & Skid Valves & Pipe AWWA, Plug, Control, etc. Steel, ductile iron, stainless steel or HDPE pipe Baseplate / Skid Steel or aluminum Stainless steel bolts Rigid and flexible conduit on Aluminum Unistrut NEC code wiring Coatings Epoxies NSF 61 Zinc

Hydroflo Valves, Pipe & Skid

Hydropneumatic Tank Not standard for Hydroflo/VFD system Allows the system to shut down all pumps. Low demand and/or system leakage slowly drain the tank until the pressure drops to the cut-in point. System reactivation brings the system pressure back up and recharges the tank. Used on systems that have periods of no flow, or very, very low flow Bladder vs. Non-bladder Small percentage of volume is useable Can be located anywhere in the system Bypass line is an alternative Control Valve

Hydropneumatic Tanks

Barney s Pumps Engineering Four P.E. s on staff Electrical and mechanical CAD dwgs 3D models available with SolidEdge Adobe Acrobat Document

Barney s Pumps Engineering

Barney s Pumps Testing Test Tank 2500 gal capacity 2000 gpm max 150 psi max Instrumentation Flow (Mag Meter) Power Pressure

Hydroflo Control Systems A framework with options Constant pressure variable speed Pressure transducer(s) with pressure switch backup Flowmeter Pump sequencing VFD feedback Flow calls Pumps always operate on their curve PLC with HMI Control other equipment SCADA interface Local wireless (spread spectrum) Mobile wireless (GSM and CDMA)

Hydroflo Control Systems System adjusts to changes in demand By adjusting pump speed By sequencing pumps on/off Energy savings Avoids running a large pump at low flows Only what is needed is provided Design point on right-side of curve Operate through the BEP H.I. Variable Speed Pumping

Hydroflo Pumps & Controls Pump selection example Engineer wanted 1000 gpm @ 200 TDH 4 main split-case pumps 75 hp Barney s Pumps selected 1375 gpm @ 200 TDH 100 hp

Hydroflo Pump Types

Hydroflo Pump Types

Hydroflo Pump Types

Hydroflo Pump Types

Hydroflo Pump Types

Hydroflo Pump Types

Hydroflo Control Systems Manufactured by Unitron Controls Wholly-owned by Barney s Pumps UL 508A, UL 698, UL QCZJ certified The heart of the UL Listed Packaged Pumping System

Control System Components Panel enclosure NEMA 3R/12, 4X, 12 NEMA starters Not IEC Circuit breakers Not fuses!!! Pressure transducer and backup switch Flowmeter Accuracy depends on application Variable Frequency Drive One or one per pump PLC and HMI

Standard Hydroflo Features Enclosure cooling Reversing starters HOA switch per pump not on HMI VFD / VFD Bypass switch VFD Speed Control switch (manual/auto) Laptop GFI PID control

Standard Hydroflo Alarms High pressure Low pressure (manual reset) Low water level PT failure (manual reset) Flowmeter failure (manual reset) Phase failure Motor start failure VFD fault (manual reset)

Human Machine Interface Color touchscreen displays Screens System status Individual pump status VFD parameters Pressure configuration Flow configuration Timer Configuration Alarms Alarm flashes to main screen Alarm page with history

Programmable Logic Controller Microprocessor based controller with many inputs and outputs Rugged and dependable (no reboots) Digital and analog I/O Ladder logic is in the software Functionality increasing Cost decreasing

Programmable Logic Controller Pros: Can handle very complex control systems. Much less wiring required (logic is internal) Can be less expensive than hardwired panel for complex systems New control sequences can be incorporated by simple reprogramming Setpoints easily changed through panel HMI External communication (Ethernet) Cons: Panel HMI or laptop required to allow access to setpoints More expensive on simple systems

Hard-wired Relays Simple technology NOT simple to use! Pros: Individual relays inexpensive / easily replaced Setpoints and time delays are mechanically manipulated and adjusted (hardware specific) Cons: Complex systems are intricate, complex & expensive Numerous components to go bad Not always easy to identify relays and wiring Not easy to change Easy to make setpoint mistakes Cannot do some things that a PLC can Control sequence can be modified within PLC without shutdown of system.

Remote Access All systems should incorporate capability Remote troubleshooting Saves service call dollars SCADA Modem High-speed connection is preferred Many components have on-board web servers Access times can be controlled by customer with use of remote access selector switch. VPN

Custom Applications

Hydroflo Support Custom mechanical & electrical design CAD drawings Specifications Standard with pump-type and datasheet inserts Witness testing at no charge Full-service start-up Remote and on-site troubleshooting Pump warranty center

Why? Availability Quality Cost Accountability Summary Hydroflo Packaged Pumping Systems offer many advantages