Pluggit iconvent Decentralized residential ventilation with heat recovery Operating and installation instructions

Similar documents
AirUnit. Installation instructions. mfh systems modern floor heating. Decentralised domestic ventilation

AirUnit. Operating manual. mfh systems modern floor heating. Decentralised domestic ventilation

Operating Manual SEVi 160 Series

Warnings, Safety Information and Guidance

The breakthrough in round ventilation pipes

Operation Manual. Control TJ-HRC

Operating instructions for the radio heat detector GS412

SD2. Differential Controller. Operating and Installation Instructions F2 72.3

Convection Panel Heater

2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC

SCHMIDT LED Measured Value Display MD Instructions for Use

Operating Manual MS220KA and MSR220KA

AIRGOCLEAN 10 E OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN

½ CAUTION ½ DANGER. Getting to know the smoke detector. ARGUS Smoke Detector Single. Accessories. Operating instructions. For your safety A B C D E

TDS 20 R / TDS 30 R / TDS 50 R

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

Operation Manual for Drying Storage Cabinet with Drying Unit U-5002

Installation and operating instruction. Digital-Thermostat. Thermo 2

Instruction manual. Digital Radar Motion Detector with Infrared Remote Control MWD BF. FEIG ELECTRONIC GmbH Lange Straße Weilburg/Lahn

LUNOS Domestic Ventilation Systems With Heat Recovery. Innovations for New Buildings and Redevelopment. e2 + e go

1. Safety instructions Mounting location in rooms of the heat detectors... 3

ST710-KHJV.03. Wiring diagram. Product description. Temperature controller. Order number

Operating Manual MS220DA

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

THERMOFILM CONVECTIVE PANEL HEATER INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Models: CP 2400 CP 2000 CP 1500 CP 1000 TABLE OF CONTENTS

SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 OPERATION MANUAL

SWARCO TRAFFIC SYSTEMS GMBH. TDD1-MW Traffic Detector User Manual TDD1-MW_BE_00

Technical information for installation and operation

Interface and EOL Modules 8

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

OPERATING INSTRUCTIONS

DS 96/48 P. Digital indicator. Short manual 41/33-89 EN Rev. 00 DIM

Electronic Smoke Detector m-rmf150

Installation manual Mini Comfort 50 S/L 07/ V EN

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Operating Manual. Kunstwinder OIL BARON

Insulation fault evaluator EDS460-DG

Gira nurse call system Installation, start-up, operation. Gira emergency set

5, SE GÅNGHESTER,

Table of Contents. 1. Mounting Tips... 2

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Installation and operating instructions KEMPER KHS-Timer-Set Figure and Figure

Accessories for Alarm Systems in the Protect Series. Instruction Manual en/en

DECENTRALIZED VENTILATION THE X series

Installation and Operating Instructions. Models: T4-12LOW-9IS

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

TCH 2000 E OPERATING MANUAL DESIGNER GLASS CONVECTOR TRT-BA-TCH2000E-TC-001-EN

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

Radiant Heater. Instruction Manual QH-200 N13275

SINGLE-ROOM ENERGY RECOVERY VENTILATORS

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60

MPK-09CRN2 / MPK1-09CRN1 / MPK1-12CRN1 DE EN IT FR NL

Decentralised ventilation systems Trust the original.

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Function description. Channel A light. Motion detector

SERIES 4000 AUTO GATE MANUAL

PORTABLE AIR CONDITIONER OWNER S MANUAL

Installation instructions. For the competent person. Installation instructions VRT 350 VRT 350 GB, IE

Remote alarm indicator and test combination MK2430

TTK 75 E OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75E-TC-002-EN

WIRING DIAGRAM. This manual describes the unit features and explains how to set-up, operate and maintain these AirPac Models. COOLIT2600 COOLIT2900

Whole Home Heat Recovery Ventilation

GMA4100-DP. Control Panel. Operation Manual. Worldwide Supplier of Gas Detection Solutions

MCS 4000 Control Panel

Ozonizer XT Instructions

EasyStart T. Installation instructions. Comfort Timer with 7-day preset capability.

Rotary Tube Furnaces

TTK 70 S OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK70S-TC-001-EN

EN Z Subject to change due to technical improvements! Operating instructions

Conductive Leakage detectors of the Leckstar range

Operating Manual MSF220V(VU)

TTV 4500 / TTV 4500 HP / TTV 7000

Datasheet CALYPSO II R. Interlinkable smoke alarm device

3. Intended use. 4. Function. 1. Product characteristics. 2. Safety. Functional description. Channel A light. Motion detector

1.7. Insulation fault evaluators EDS460/490 EDS461/491

B 400. Operating Manual Humidifier B 400

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

IT system floor-standing distribution

Mounting bezel Retaining spring. Detects movement within the detection range, allowing load control in response to changes in room occupancy.

DS English... 5 Français Español CONSUMO DE ENERGIA. 1. En Operación: 287,82 Wh 2. En Modo de Espera: N/A Modelo: DS 5.

User manual UV Flash Dry C1

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

Operating Instructions Version 1.2

LS800S Intruder Alarm System. Engineering Manual

GE Lighting. Lighting Controls. DALI Digital Lighting Controls

Supplement to operating and installation manual no for the VR 81 remote control unit

Alarm System SECURE AS 302

Operating instructions

3-way switching valve

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

USER MANUAL HD SERIES. WARNING Read the instructions before using the machine. EN (Original Instruction) / 1704 HD5.

EN ES-D5B Wireless Smoke Detector. Instrukcja pobrana ze sklepu

Operating Instructions UniTech Perfect

UBS1RF OPTICAL SMOKE ALARM EN 14604:2005/AC:2008 DOP:UBS1RF-001-V1

Electric Hand dryer. Installation and operating manual

Air. Pressure. Motion. nnnnnnnn

Turbo Inline Fan, White - Non Illuminated Art no.33500

Installer manual AG-WL10

Operating manual GTL 369 GTL 369M GTL 389 GTL 389M. Temperature probe. Please keep the manual for future use.

SOUND-INSULATED FAN. Iso-B OPERATION MANUAL

Transcription:

git iconvent Decentralized residential ventilation with heat recovery Operating and installation instructions www.pluggit.com

The technology makes the difference. Innovations of git with an added value for the human being and environment. Q The Q-ventilation typical for PLUGGIT room systems guarantees efficiency and comfort for the distribution of supply air. The first Q - the displacement ventilation - distributes the fresh air very slowly without any background noises and draughts in the room. The second Q - the cross ventilation - causes a complete air flow of the room. In this, the fresh air outlet in the outside wall area is positioned as far away as possible from the door of the supply air room. The special PLUGGIT iqoanda-air outlet is positioned above the access of the supply air room, if possible. The Qoanda effect leads the air flow along the ceiling in the furthest corner of the room. By means of this type of flow a comprehensive air quality is ensured without any background noises and draughts. allfloor ServoFlow The distribution systems of PLUGGIT allow an installation of pipe systems at all three installation levels. For new buildings or renovation the ventilation ducts can be assembled safely and easily: in the insulating layer of the floor, in the bare concrete of the ceiling or below the ceiling. The innovative and unique PLUGGIT ServoFlow-technology guarantees the supply of utilization-oriented air volume for a building at any time. Above all, it ensures the important balance of supply and exhaust air flows by means of an automatically conducted calibration once a week and documents modifications, like the filter contamination in the plant. The energy efficiency of ventilation units is defined by two factors. The high heat recovery of our ventilation units ensures low heat losses and comfortable supply air temperatures. Decisive, however, is the power consumption. By means of highly efficient direct current vans the operating costs are reduced to a minimum. Thus, the ratio of heat recovery and power consumption, which means the efficiency, is the most significant value and is defined as coefficient of performance. At the coefficients of performance PLUGGIT ventilation units achieve maximum values of up to and thus guarantee an excellent energy efficiency. CleanSafe CleanSafe stands for an easy cleaning. As a first company PLUGGIT had a cleaning system certified which facilitates cost-effective cleaning and maintenance of all system components, whether a round tube or a shallow duct distribution system is installed. Fresh air and heat supply in one system - faster, more flexible and more energysaving than common heating systems. Perfect feel-good climate by means of optimal air humidity in the room air with the air humidifier AeroFresh.

TABLE OF CONTENTS. General safety instructions.... General notes..... Appropriate use..... Non-appropriate use..... Warranty.... Overview..... Single-room ventilation unit iconvent Mono..... Single-room ventilation unit iconvent Duo.... Function/principle..... Single-room ventilation unit iconvent Duo..... Single-room ventilation unit iconvent Mono... 7.. Cross ventilation... 8.. Installation type single-room ventilation unit iconvent Duo... 9.. Installation type single-room ventilation unit iconvent Mono and iconvent Duo... 0.. Installation type single-room ventilation unit iconvent Duo and exhaust air van....7. Installation type single-room ventilation unit iconvent Mono, iconvent Duo and exhaust air van....8. Regulation....8.. Regulation schemes....9. Time-delay relay....9.. Connection diagram....9.. Technical data....9.. Measurements.... Installation (qualified staff)..... Notes for installation..... Assemble installation stone ICVS and installation sleeve ICVH...... Installation stone ICVS for single-room ventilation unit iconvent Mono...... Installation stone ICVS for single-room ventilation unit iconvent Duo...... Installation sleeve ICVH for single-room ventilation unit iconvent Mono...... Installation sleeve ICVH for single-room ventilation unit iconvent Duo..... Install single-room ventilation unit..... Initial operation... 7 BIA Single room ventilation unit iconvent Mono and iconvent Duo

.. Technical data... 8... Unit data... 8... Regulation... 8... Measurements... 8... Basic wiring diagram, electrical... 0. Operation (user)..... Overview regulation..... Increase/ reduce fan level..... Reset filter alarm..... Error correction...... Disturbances... 7. Maintenance (user)... 7.. Clean inside panel... 7.. Clean ceramic heat exchanger... 7.. Clean/ change filter... 8. Decommissioning/disposal... 8.. Decommissioning at extension... 8.. Packaging... 8.. Old unit... BIA Single room ventilation unit iconvent Mono and iconvent Duo

. GENERAL SAFETY INSTRUCTIONS. GENERAL NOTES Warning: The following safety instructions shall be noted, otherwise injuries or damages can be implied: Before you begin with the installation and operation of the decentralized single-room ventilation unit, carefully read these operation and installation instructions. The installation and all electrical works shall only be carried out by qualified staff. Consider all necessary legal and national standards (accident prevention regulations and acknowledged rules of technology) for the installation and initial operation of the decentralized single-room ventilation unit and observe them. Damages which occur due to product-inappropriate storage, improper operation and installation or non-appropriate use are excluded from each kind of liability. Subject to technical changes... APPROPRIATE USE The decentralized single-room ventilation unit iconvent Mono and iconvent Duo serve as regulated aeration and ventilation of individual supply air rooms, for example, living rooms and children's rooms as well as exhaust air rooms, for example, kitchen and bathroom with window in accordance with DIBt-approval... NON-APPROPRIATE USE Other uses of the decentralized single-room ventilation unit than those described under "appropriate use" are inadmissible. The decentralized single-room ventilation unit shall not be applied for construction drying... WARRANTY For a full legal warranty claim the technical standards of these operating and installation instructions shall be observed. BIA Single room ventilation unit iconvent Mono and iconvent Duo

. OVERVIEW.. SINGLE-ROOM VENTILATION UNIT ICONVENT MONO 7.. git iconvent inside panel Mono ICVM-B Base plate, inside git iconvent functional unit ICVF. git iconvent installation stone ICVS. git iconvent installation sleeve ICVH Base plate, outside Insulation mat 7 git iconvent weather protection grid Mono ICVM-WSG M+P-A-0 Depending on the construction plan the git iconvent installation sleeve ICVH (.) can also be used instead of the git iconvent installation stone ICVS (.). This is designed as round EPP sleeve 98 mm. BIA Single room ventilation unit iconvent Mono and iconvent Duo

.. SINGLE-ROOM VENTILATION UNIT ICONVENT DUO.. 7 git iconvent inside panel Duo ICVD-B Base plate, inside git iconvent functional unit ICVF. git iconvent installation stone ICVS. git iconvent installation sleeve ICVH Base plate, outside Insulation mat 7 git iconvent weather protection grid Duo ICVD-WSG M+P-A-0 Depending on the construction plan the git iconvent installation sleeve ICVH (.) can also be used instead of the git iconvent installation stone ICVS (.). This is designed as round EPP sleeve 98 mm. BIA Single room ventilation unit iconvent Mono and iconvent Duo

. FUNCTION/PRINCIPLE.. SINGLE-ROOM VENTILATION UNIT ICONVENT DUO Rotation direction A Rotation direction B Outside wall Outside wall up up down Inside wall M+P-A-0 down Inside wall M+P-A-0 Single-room ventilation unit iconvent Duo Single-room ventilation unit iconvent Duo Functional unit supply air operation Functional unit supply air operation Supply air Supply air Functional unit exhaust air operation Functional unit exhaust air operation Exhaust air Exhaust air For the hygienically necessary exchange of air outside air is fed into the functional unit () of the single-room ventilation unit () and transported in the living room as supply air (). Humid and used exhaust air () is discharged through the functional unit () out of the building. Approximately each 80 seconds the rotation direction of the fans in the functional units () and () is changed. This way, also the direction of supply air () and exhaust air () is changed. The ceramic heat exchanger of the functional unit () is heated by the inside room temperature. This heat is supplied at the change of rotation direction of the supply air (). Due to this operation a permanent heat recovery is achieved. BIA Single room ventilation unit iconvent Mono and iconvent Duo

.. SINGLE-ROOM VENTILATION UNIT ICONVENT MONO Rotation direction A Rotation direction B Outside wall Outside wall up up Inside wall down M+P-A-07 Inside wall down M+P-A-08 Single-room ventilation unit iconvent Mono Single-room ventilation unit iconvent Mono Functional unit supply air operation Functional unit exhaust air operation Supply air Exhaust air The change of rotation direction of the fan in the singleroom ventilation unit iconvent Mono () is carried out correspondingly as in the single-room ventilation unit iconvent Duo. The single-room ventilation units iconvent Mono () shall be operated in pairs for a regulation. This means one unit runs in supply air operation whereas the second unit simultaneously runs in exhaust air operation. The change of rotation direction is also conducted simultaneously in pairs. Only this way the balance between supply and exhaust air volume stream required according to DIN 9- and DIBt-approval can be guaranteed. BIA Single room ventilation unit iconvent Mono and iconvent Duo 7

.. CROSS VENTILATION +% +% +% +/-0% +/-0% +% 8 9 7 Sample installation Single-room ventilation units Regulation Cross ventilation Supply air room, for example, living room and dining room Supply air room, for example, bedroom Supply air room, for example, guest room 7 Supply air room, for example, bathroom with window 8 Exhaust air room, for example, kitchen with window 9 Overflow area, for example, corridor or hall Thus the single-room ventilation units () can be controlled by the regulation (), so that a sufficient cross ventilation () of the entire utilization unit is guaranteed. For the realisation of cross ventilation () the supply air volume flows in this sample installation, for example, in the living room and dining room (), must be increased by + %. In the opposite rooms, for example, in the bedroom () and guest rooms (), the exhaust air volume flows must by higher by + %. Additionally suitable overflow openings, for example, door undercuts are necessary. In exhaust air rooms with windows, for example, bathroom (7) and kitchen (8), no cross ventilation is necessary. Here the single-room ventilation units () must be operated in balance according to the DIBt-approval. This means they run independently with regard to air technology, independent from the settings of the supply air rooms. In such a case either two single-room ventilation units iconvent Mono or one single-room ventilation unit iconvent Duo must be installed. In the overflow sector, for example, corridor or hall (9), an own single-room ventilation unit can be renounced, because, as a rule, the cross ventilation () is sufficient, in order to achieve a sufficient air exchange in these rooms. M+P-A-0 8 BIA Single room ventilation unit iconvent Mono and iconvent Duo

.. INSTALLATION TYPE SINGLE-ROOM VENTILATION UNIT ICONVENT DUO The described installation type is valid for bathrooms with integrated window. +% +% +% +/-0% +/-0% +% 8 9 7 Sample installation Single-room ventilation unit iconvent Duo Regulation Cross ventilation Supply air room, for example, living and dining room Supply air room, for example, bedroom Supply air room, for example, guest room or children's room 7 Exhaust air room, for example, bathroom with window 8 Exhaust air room, for example, kitchen with window 9 Overflow area, for example, corridor or hall M+P-A-0 BIA Single room ventilation unit iconvent Mono and iconvent Duo 9

.. INSTALLATION TYPE SINGLE-ROOM VENTILATION UNIT ICONVENT MONO AND ICONVENT DUO The described installation type is valid for bathrooms with integrated window. +/-0% +/-0% 8 9 7 Sample installation Single-room ventilation unit iconvent Mono Single-room ventilation unit iconvent Duo Regulation Supply air room, for example, living and dining room Supply air room, for example, bedroom Supply air room, for example guest room or children's room 7 Exhaust air room, for example, bathroom with window 8 Exhaust air room, for example, kitchen with window 9 Overflow area, for example, corridor or hall M+P-A-0 0 BIA Single room ventilation unit iconvent Mono and iconvent Duo

.. INSTALLATION TYPE SINGLE-ROOM VENTILATION UNIT ICONVENT DUO AND EXHAUST AIR VAN The described installation type is valid for inside bathrooms without window according to DIN 807-. +m /h +m /h +m /h +/-0% VAB = 0m /h +m /h Sample installation Single-room ventilation unit iconvent Duo Exhaust air fan according to DIN 807- Regulation Supply air room, for example, living and dining room Supply air room, for example, bedroom Supply air room, for example, guest room or children's room 7 Exhaust air room, for example, bathroom without window 8 Exhaust air room, for example, kitchen with window 9 Overflow area, for example, corridor or hall In flats with an inside bathroom without window (7) an exhaust air fan () must be installed according to DIN 807-. This has to generate an exhaust air volume flow of 0 m³/h (V AB ). 8 9 7 To realize a balanced air exchange additional volume flows must be generated in the supply air rooms, which balance the air volume flow of the exhaust air fan. Only this way it can be ensured that there is no vacuum in the utilization unit and the single-room ventilation units () which are in exhaust air operation can continue to generate heat recovery. Example: The exhaust air fan () is connected with two regulations () of supply air rooms, as it is described here. The supply air volume flow of the single-room ventilation units () must be adjusted respectively + m³/h higher in the supply air operation. By this, in total the 0 m³/h exhaust air volume flow of the exhaust air fan () is compensated. The single-room ventilation unit () in the kitchen (8) continues to run in balance. BIA Single room ventilation unit iconvent Mono and iconvent Duo M+P-A-07

.7. INSTALLATION TYPE SINGLE-ROOM VENTILATION UNIT ICONVENT MONO, ICONVENT DUO AND EXHAUST AIR VAN The described installation type is valid for inside bathrooms without window according to DIN 807-. +0m /h +0m /h 7 +/-0% VAB = 0m /h Sample installation Single-room ventilation unit iconvent Mono Single-room ventilation unit iconvent Duo Exhaust air fan according to DIN 807- Regulation Supply air room, for example, living and dining room Supply air room, for example, bedroom 7 Supply air room, for example, guest room or children's room 8 Exhaust air room, for example, bathroom without window 9 Exhaust air room, for example kitchen with window 0 Overflow area, for example, corridor or hall The installation type with single-room ventilation unit iconvent Mono (), iconvent Duo () and exhaust air fan () is carried out correspondingly. BIA 9 0 8 Single room ventilation unit iconvent Mono and iconvent Duo M+P-A-08 Example: The exhaust air fan () is also connected with the regulation (), which also controls the single-room ventilation units () for the cross ventilation. The supply air volume flow of the single-room ventilation units () must be adjusted respectively +0 m³/h higher, as soon as and as long as the exhaust air fan () is in operation. Thus, in total the 0 m³/h (V AB ) exhaust air volume flow of the exhaust air fan () is compensates and hear recovery is guaranteed. The single-room ventilation units iconvent Mono () and iconvent Duo () can be adjusted to various additional volume flows depending on the number of installed units. The single-room ventilation unit iconvent Duo () in the kitchen (9) continues to run in balance.

9ABCDEF08.8. REGULATION 7 For the single-room ventilation units, which are always installed in pairs in the exhaust air rooms, for example, kitchen, bathroom and toilet with window, always both upper plug s () and () shall be used. As supply line for the supply voltage of the regulation (8) an insulated cable x. mm² shall be applied. Depending on the cable length the following insulated cables are applied as control wire for the single-room ventilation units: Cable length 0- m: x 0. mm² Cable length -0 m: x 0. mm² E E 8 Cable length 0- m: x 0.8 mm² 7 0 x,mm functional unit (exhaust air) functional unit (supply air) functional unit (exhaust air) functional unit (supply air) functional unit (exhaust air) functional unit (supply air) 7 External entry, potential-free 0/0 V the time-delay relay at the connection E (arrow). 8 Regulation M+P-A-0 The single-room ventilation units iconvent Mono and iconvent Duo as well as the exhaust air fan are controlled by a regulation ICVC (8). This has six plug s (-) for the connection of the single-room ventilation units as well as one plug (7) for the connection of the exhaust air fan. The connection of two single-room units iconvent Mono or one iconvent Duo always shall be carried out at the horizontally opposite plug s. The regulation is carried out by the rotary switch (0). Depending on the required air volume flow various operating modes can be adjusted, see from page onwards. Level C-F are without function assignment. M+P-A- BIA Single room ventilation unit iconvent Mono and iconvent Duo

.8.. Regulation schemes Legend M+P-A-80 iconvent regulation Additional volume flow supply air Additional volume flow exhaust air Example connection level x,mm² / 0V / 0Hz N Example: kitchen +0m³/h Example: bedroom +0m³/h Example: children s room PE L Example: Dining room +0m /h additional volume flow Example: Living room +0m /h additional volume flow Connection insulated cable Cable length 0- m: x 0. mm² Cable length -0 m: x 0. mm² Cable length 0- m: x 0.8 mm² M+P-A-09 Analogous to the below described example of level the connection of all levels is carried out. BIA Single room ventilation unit iconvent Mono and iconvent Duo

Level 0 A B Rotation direction A Rotation direction A Rotation direction A Position Supply air Exhaust air Supply air Exhaust air Supply air Exhaust air Level 0 Balance Balance Balance Balance Balance Balance Rotation direction B Rotation direction B Rotation direction B Position Exhaust air Supply air Exhaust air Supply air Exhaust air Supply air Level 0 Balance Balance Balance Balance Balance Balance Level A + % + % B + % + % Rotation direction A Rotation direction A Rotation direction A Position Supply air Exhaust air Supply air Exhaust air Supply air Exhaust air Level Balance Balance + % +/ % +/ % + % Rotation direction B Rotation direction B Rotation direction B Position Exhaust air Supply air Exhaust air Supply air Exhaust air Supply air Level Balance Balance +/ % + % + % +/ % BIA Single room ventilation unit iconvent Mono and iconvent Duo

Level A + 0m³/h + 0m³/h B + 0m³/h + 0m³/h Rotation direction A Rotation direction A Rotation direction A Position Supply air Exhaust air Supply air Exhaust air Supply air Exhaust air Level Balance Balance +0 m³/h +/ % +0 m³/h +/ % Rotation direction B Rotation direction B Rotation direction B Position Exhaust air Supply air Exhaust air Supply air Exhaust air Supply air Level Balance Balance +/ % +0 m³/h +/ % +0 m³/h Level A +,m³/h +,m³/h B +,m³/h +,m³/h Rotation direction A Rotation direction A Rotation direction A Position Supply air Exhaust air Supply air Exhaust air Supply air Exhaust air Level Balance Balance +. m³/h +/ % +. m³/h +/ % Rotation direction B Rotation direction B Rotation direction B Position Exhaust air Supply air Exhaust air Supply air Exhaust air Supply air Level Balance Balance +/ % +. m³/h +/ % +. m³/h BIA Single room ventilation unit iconvent Mono and iconvent Duo

Level A + m³/h + m³/h B + m³/h + m³/h Rotation direction A Rotation direction A Rotation direction A Position Supply air Exhaust air Supply air Exhaust air Supply air Exhaust air Level Balance Balance + m³/h +/ % + m³/h +/ % Rotation direction B Rotation direction B Rotation direction B Position Exhaust air Supply air Exhaust air Supply air Exhaust air Supply air Level Balance Balance +/ % + m³/h +/ % + m³/h Level A + 0m³/h + 0m³/h B + 0m³/h + 0m³/h Rotation direction A Rotation direction A Rotation direction A Position Supply air Exhaust air Supply air Exhaust air Supply air Exhaust air Level Balance Balance +0 m³/h +/ % +0 m³/h +/ % Rotation direction B Rotation direction B Rotation direction B Position Exhaust air Supply air Exhaust air Supply air Exhaust air Supply air Level Balance Balance +/ % +0 m³/h +/ % +0 m³/h BIA Single room ventilation unit iconvent Mono and iconvent Duo 7

Level A + 0m³/h + 0m³/h B + 0m³/h + 0m³/h Rotation direction A Rotation direction A Rotation direction A Position Supply air Exhaust air Supply air Exhaust air Supply air Exhaust air Level Balance Balance +0 m³/h +/ % +0 m³/h +/ % Rotation direction B Rotation direction B Rotation direction B Position Exhaust air Supply air Exhaust air Supply air Exhaust air Supply air Level Balance Balance +/ % +0 m³/h +/ % +0 m³/h Level 7 A + 0m³/h + 0m³/h + 0m³/h B + 0m³/h + 0m³/h + 0m³/h Rotation direction A Rotation direction A Rotation direction A Position Supply air Exhaust air Supply air Exhaust air Supply air Exhaust air Level 7 +0 m³/h +/ % +0 m³/h +/ % +0 m³/h +/ % Rotation direction B Rotation direction B Rotation direction B Position Exhaust air Supply air Exhaust air Supply air Exhaust air Supply air Level 7 +/ % +0 m³/h +/ % +0 m³/h +/ % +0 m³/h 8 BIA Single room ventilation unit iconvent Mono and iconvent Duo

Level 8 A +,m³/h +,m³/h +,m³/h B +,m³/h +,m³/h +,m³/h Rotation direction A Rotation direction A Rotation direction A Position Supply air Exhaust air Supply air Exhaust air Supply air Exhaust air Level 8 +. m³/h +/ % +. m³/h +/ % +. m³/h +/ % Rotation direction B Rotation direction B Rotation direction B Position Exhaust air Supply air Exhaust air Supply air Exhaust air Supply air Level 8 +/ % +. m³/h +/ % +. m³/h +/ % +. m³/h Level 9 A + m³/h + m³/h + m³/h B + m³/h + m³/h + m³/h Rotation direction A Rotation direction A Rotation direction A Position Supply air Exhaust air Supply air Exhaust air Supply air Exhaust air Level 9 + m³/h +/ % + m³/h +/ % + m³/h +/ % Rotation direction B Rotation direction B Rotation direction B Position Exhaust air Supply air Exhaust air Supply air Exhaust air Supply air Level 9 +/ % + m³/h +/ % + m³/h +/ % + m³/h BIA Single room ventilation unit iconvent Mono and iconvent Duo 9

Level A A + 0m³/h + 0m³/h + 0m³/h B + 0m³/h + 0m³/h + 0m³/h Rotation direction A Rotation direction A Rotation direction A Position Supply air Exhaust air Supply air Exhaust air Supply air Exhaust air Level A +0 m³/h +/ % +0 m³/h +/ % +0 m³/h +/ % Rotation direction B Rotation direction B Rotation direction B Position Exhaust air Supply air Exhaust air Supply air Exhaust air Supply air Level A +/ % +0 m³/h +/ % +0 m³/h +/ % +0 m³/h Level B A + 0m³/h + 0m³/h + 0m³/h B + 0m³/h + 0m³/h + 0m³/h Rotation direction A Rotation direction A Rotation direction A Position Supply air Exhaust air Supply air Exhaust air Supply air Exhaust air Level B +0 m³/h +/ % +0 m³/h +/ % +0 m³/h +/ % Rotation direction B Rotation direction B Rotation direction B Position Exhaust air Supply air Exhaust air Supply air Exhaust air Supply air Level B +/ % +0 m³/h +/ % +0 m³/h +/ % +0 m³/h Level C-F are without function assignment. 0 BIA Single room ventilation unit iconvent Mono and iconvent Duo

.9. TIME-DELAY RELAY The time-delay relay 0 V AC with control input and potential-free solid state relay exit is applied in connection with an exhaust air fan on site. As soon as the control input is triggered (room lighting is switched on), a timer is started for the start delay. After the expiration of the start delay the output relay is activated and connects both white connections of the timedelay relay with the single-room ventilation unit iconvent. After the release of the control signal the time delay begins. If during a time delay the input is again triggered, this is only considered when the adjusted start delay has been achieved. Dependent on the settings of the exhaust air fan on site the start delay and stop delay must be adjusted in the timedelay relay..9.. Connection diagram L N S Exhaust air fan (on site) Time-delay relay Single-room ventilation unit iconvent.9.. Technical data M+P-A- Start delay Stop delay Supply voltage 0 V AC Operating voltage sector 9- V AC 0 seconds minutes seconds 0 minutes Power consumption Standby at 0 V AC Input resistance Maximum permissible switching voltage at the exit Maximum permissible load current at the exit Output resistance Connections pipes.9.. Measurements 0 mw 80 kω 8 V 00 ma 0 Ω x LiY 0, mm² (strands) 00 m length 0 seconds minutes 8. 0 seconds minutes.0 The voltage supplied to the exit shall not exceed 8 V. Install the time-delay relay as close to the regulation as possible..0 9.0 M+P-A- BIA Single room ventilation unit iconvent Mono and iconvent Duo

. INSTALLATION (QUALIFIED STAFF) Warning: The installation of the single-room ventilation unit shall only be implemented by qualified staff to avoid injuries or damages... NOTES FOR INSTALLATION The installation stones ICVS and installation sleeves ICVH for the installation of the single-room ventilation units have to be installed in the outside walls, see page. The shell construction must be concluded and the complete wall structure must be terminated. For the wall structure the git iconvent plaster tissue ICV-PG must be integrated with the interior plaster. A coordination with the electrician has to be made that the electric lines are integrated in the groove of the installation stones ICVS or installation sleeves ICVH and are labeled with the corresponding room designation in the provided double cavity wall flush-mounted socket for the regulation. Depending on the necessary air exchange in each supply and exhaust air room one or several single-room ventilation units can be installed. The correct settings of the air volume flows must be considered. The air flow shall not be obstructed by furniture, curtains or similar things. The single-room ventilation units iconvent Mono always must be operated in pairs on a regulation. The single-room ventilation units must be freely accessible for all maintenance works. The single-room ventilation units shall only be taken into operation after terminating all installation works. BIA Single room ventilation unit iconvent Mono and iconvent Duo

.. ASSEMBLE INSTALLATION STONE ICVS AND INSTALLATION SLEEVE ICVH... Installation stone ICVS for single-room ventilation unit iconvent Mono up Inside min. 8 mm down min., m min. mm min. 0 mm mm min. 0 mm 0 mm min. 8 mm mm min., m Inside Plaster % Outside Plaster M+P-A-... Installation stone ICVS for single-room ventilation unit iconvent Duo up Inside min., m min. 8 mm down min. mm min. 0 mm mm min. 0 mm 0 mm min. 8 mm mm min., m Inside Plaster % Outside Plaster M+P-A- BIA Single room ventilation unit iconvent Mono and iconvent Duo

98 mm... Installation sleeve ICVH for single-room ventilation unit iconvent Mono up Inside min. 8 mm down min., m Ø 00 mm min. 0 mm Ø 98 mm min. 8 mm mm min., m Inside Plaster % Outside Plaster M+P-A-... Installation sleeve ICVH for single-room ventilation unit iconvent Duo up Inside min. 8 mm down min., m Ø 00 mm Ø 00 mm min. 0 mm Ø 98 mm Ø 98 mm min. 8 mm mm min., m Inside Plaster % Outside Plaster M+P-A- BIA Single room ventilation unit iconvent Mono and iconvent Duo

.. INSTALL SINGLE-ROOM VENTILATION UNIT The installation of the single-room ventilation unit iconvent Mono and the installation of the single-room ventilation unit with the installation sleeve ICVH is carried out correspondingly. Outside wall Inside wall 7 M+P-A-. Make drill holes for base plate inside () as described.. Attach base plate inside () with screws (7). up For the assembly of installation stones () use the insulation fixings contained in the scope of delivery and for the assembly of the installation sleeves ICVH use the universal dowels contained in the scope of delivery. A change to the iconvent design panel is possible with identical drillings in the base plate. un M+P-A-0. Remove construction protection () and ().. Insert the plug () in groove (). Do not dispose of construction protection () and (). These are required as manual locking mechanisms, for example, at outside air contaminations. BIA Single room ventilation unit iconvent Mono and iconvent Duo

9 + red s purple - blue 9 8 M+P-A-8 9. Make drill holes for base plate outside () as described. 0 9 8 M+P-A- For the assembly of installation stones () use the insulation fixings contained in the scope of delivery and for the assembly of the installation sleeves ICVH use the universal dowels contained in the scope of delivery.. Insert functional units (8) until the stop in the installation stones ().. Connect plug () with plug (9). 7. Insert filter inside (0). 0. Attach base plate outside () with screws (). M+P-A-0. Insert insulation mat () in the groove of the base plate outside (). 8. Attach inside panel () on base plate inside (). M+P-A-8. Attach weather protection grid () on the base plate outside (). BIA Single room ventilation unit iconvent Mono and iconvent Duo

9ABCDEF08.. INITIAL OPERATION 7 7 M+P-A-07. Insert regulation with control unit () in installed double cavity wall flush-mounted socket (7). M+P-A- All installed regulations () which are required according to the air volume flow, see from page onwards. BIA Single room ventilation unit iconvent Mono and iconvent Duo 7

.. TECHNICAL DATA... Unit data... Measurements Single-room ventilation unit iconvent Mono Weight iconvent Mono Weight iconvent Duo approx. kg incl. panels approx. 0 kg incl. panels I Supply voltage Energy consumption level Air volume flow Rotation speed control V DC.7 W Level : 8 m³/h Level : 0 m³/h Level : 8 m³/h -stage adjustable in advance E G C H J D Fan Axial fan piece per functional unit F B A Heat exchanger Filter Heat provision level according to DIBt-approval... Regulation Supply voltage Overall performance Control voltage Recommended performance cross section Technical ceramic in hexagonal structure Filter quality G (inside) Filter quality G (outside) approx. 9 % 0 V AC, 0 Hz until W V x. mm² for supply voltage x 0. mm² (at cable length 0- m) for control line per functional unit x 0. mm² (at cable length -0 m) for control line per functional unit x 0.8 mm² (at cable length 0- m) for control line per functional unit min. x 0. mm² for external entry A Total depth installation stone 00 mm B Minimum installation depth 8 mm C Width installation stone 0 mm D Height installation stone mm E Depth inside panel 0 mm F Width inside panel 0 mm G Height inside panel 00 mm H Depth weather protection grid mm I Width weather protection grid 9 mm J Height weather protection grid 90 mm B A C M+P-A-08 Connections External entry 8 BIA six functional units, at maximum Single room ventilation unit iconvent Mono and iconvent Duo A Overall depth installation sleeve 00 mm B Minimum installation depth 8 mm C Diameter installation sleeve 98 mm

Single-room ventilation unit iconvent Duo I E G C F B A H J D C B A M+P-A-8 M+P-A-09 A Total depth installation stone 00 mm B Minimum installation depth 8 mm C Width installation stone 0 mm A Overall depth installation sleeve 00 mm B Minimum installation depth 8 mm C Diameter installation sleeve 9 mm D Height installation stone mm E Depth inside panel 0 mm F Width inside panel 0 mm G Height inside panel 00 mm H Depth weather protection grid 8 mm I Width weather protection grid 9 mm J Height weather protection grid 89 mm BIA Single room ventilation unit iconvent Mono and iconvent Duo 9

blue -... Basic wiring diagram, electrical L N PE 0V/0Hz Min. x, mm git Relay white white 0V/0V potential-free min. x0, mm Time-delay relay Exhaust air fan on site with follow-up. Please consider connection plan of the exhaust air fan. M. V E E red + purple S iconvent Duo e.g. kitchen, bathroom iconvent Mono e.g. living room iconvent Mono e.g. bedroom iconvent Mono e.g. children s room iconvent Mono e.g. dining room M+P-A- Connection insulated cable Cable length 0- m: x 0. mm² Cable length -0 m: x 0. mm² Cable length 0- m: x 0.8 mm² the time-delay relay at the connection E (arrow). 0 BIA Single room ventilation unit iconvent Mono and iconvent Duo

. OPERATION (USER).. INCREASE/ REDUCE FAN LEVEL On demand the fan level can be manually increased or reduced. All descriptions in this chapter "operation" may be carried out by the user. All settings of a regulation are taken over for all singleroom ventilation units connected with this regulation... OVERVIEW REGULATION M+P-A-7 7 Press key () to increase or key () to reduce the fan level. Correspondingly to the fan level the number of LEDs () flashes. In case of operation of the single-room ventilation unit at fan level the unit changes automatically to fan level after hours. Increase fan stage Reduce fan stage 9 Switch on winter operation Approximately each 80 seconds the rotation direction of the fans in the functional units changes. Switch on summer operation A change of rotation direction and heat recover do not take place. LEDs for fan stages - LED lights at switched on winder operation. 7 LED lights at switched on summer operation. 8 LED flashes without interruption if a change of filter is required. 9 LED flashes three times if there is a communication problem with the functional units. LED flashes six times if there is a system error. 8 M+P-A-.. RESET FILTER ALARM The filter alarm () flashes in a factory-adjusted manner after 80 days. The filter must be cleaned or changed and the filter alarm must be reset. M+P-A- Keep key () and () pressed. The filter alarm is reset. The LED () expires. BIA Single room ventilation unit iconvent Mono and iconvent Duo

.. ERROR CORRECTION... Disturbances Disturbance The air exchange is too low. Potential reason Remedy The filters are clogged. Control filter of contamination and, if necessary, change it, see page. Reset filter alarm. The adjusted fan level is too low. If necessary, adjust higher fan level, see page. Disturbance A single-room ventilation unit causes too many noises and vibrates. Potential reason A fan has an unbalance. Remedy Request customer service of the specialized company and have the functional unit controlled and, if necessary changed. Disturbance The LED () flashes three times. One or several single-room ventilation units do not work anymore. The fans do not rotate. M+P-A-8 Potential reason Line voltage is interrupted. There is a communication problem. Remedy Re-establish line voltage. Request customer service of the specialized company and have functional unit or fans controlled and, if necessary, changed. Disturbance The LED () flashes six times. A regulation does not work. M+P-A-8 Potential reason Line voltage is interrupted. There is a system error. Remedy Re-establish line voltage. Request customer service of the specialized company. Have regulation group controlled and, if necessary, changed. BIA Single room ventilation unit iconvent Mono and iconvent Duo

7. MAINTENANCE (USER) All descriptions in this chapter "maintenance" may be implemented by the user. 7.. CLEAN CERAMIC HEAT EXCHANGER Risk of injury: Before all cleaning works disconnect all poles of the single-room ventilation unit from the power supply, otherwise it can cause injuries. All maintenance works shall be carried out for the single-room ventilation units iconvent Mono and iconvent Duo. The following descriptions are demonstrated on the basis of the example of a single-room ventilation unit iconvent Duo and are implemented for the iconvent Mono correspondingly. Control and clean the ceramic heat exchanger for contamination each months. Only use warm water for cleaning. 7.. CLEAN INSIDE PANEL Risk of injury: Before all cleaning works disconnect all poles of the single-room ventilation unit from the power supply, otherwise it can cause injuries. M+P-A-7. Remove inside panel ().. Remove inside panel ().. Clean inside panel () with a damp cloth and neutral cleaning agent.. The installation is carried out in reverse order. M+P-A-7. Take out filter ().. Pull out plug ().. Pull out functional units (). BIA Single room ventilation unit iconvent Mono and iconvent Duo

M+P-A-09. Ceramic heat exchanger () out of functional units (), soak it with warm water and then drain entire water.. The installation is carried out in reverse order. 7.. CLEAN/ CHANGE FILTER By means of the installed filters the air is cleaned from dirt particles and the contamination of the heat exchanger is prevented. The operation of the single-room ventilation unit without filter can imply an increased contamination in the heat exchanger and of the fan, so that a hygienic operation is not guaranteed. Control the filter inside and outside approximately each six months and change them at least once per year. Risk of injury: Before all cleaning works disconnect all poles of the single-room ventilation unit from the power supply, otherwise it can cause injuries.. Remove inside panel ().. Take out filter () and clean or change it.. Pull out plug ().. Pull out functional units ().. Take out filter () and clean and change it.. Reset filter alarm, see page. 7. The installation is carried out in reverse order. M+P-A-7 BIA Single room ventilation unit iconvent Mono and iconvent Duo

8. DECOMMISSIONING/DISPOSAL 8.. DECOMMISSIONING AT EXTENSION The decommissioning may only be carried out by qualified staff. Disconnect plant from mains voltage. Disconnect all poles of the plant from the power. 8.. PACKAGING The transport and protection packaging is produced from reusable materials. All packaging materials shall be disposed off according to the local stipulations. 8.. OLD UNIT The single-room ventilation units contain valuable materials and substances, which shall not get into the residual waste. The old units can be transferred to a local recycling operation for reutilization. BIA Single room ventilation unit iconvent Mono and iconvent Duo

Further good ideas of git Avent AP90/AP0/AP0 Ventilation Units gline Design Floor-Mounted Air Diffuser gvoxx Air Processing AeroFresh Plus Air Humidification V0.0/ M-BIA-iconVent-E PLUGGIT GmbH Valentin-Linhof-Straße 889 Munich Germany Telephone +9 89-0 Fax +9 89-00 www.pluggit.com