investment in R&D, the commitment to - name.

Similar documents
Campbell Soup Company Extends Use of CO2 Systems Into Their Operations

CO2 TRANSCRITICAL BOOSTER SYSTEMS

Environmentally friendly refrigeration systems for industrial use

Brazed Plate Heat Exchanger for CO Applications

DeCO2ded: Understanding ROI on CO2 Refrigeration Systems

Commercial Refrigeration

Use of transcritical CO 2 in industrial applications

PRICE CHOPPER SARATOGA, NY. First cascade supermarket system in North America Installed and Started March of 2008

Ammonia. Background on ammonia as a refrigerant

SUBCRITICAL & TRANSCRITICAL SYSTEMS

System Design, Commissioning, Operation

PACKAGED REFRIGERATION EQUIPMENT

TrilliumSeries Condenser 1 TRILLIUMSERIES CONDENSER 10 ECOFLEX CONTROLS 11 SELECTION AND PAYBACK ANALYSIS SOFTWARE 3 BENEFITS 8 MODES OF OPERATION

Applying the Frick Low Charge Central System to a New Freezer/Cooler Facility

Emerging Refrigeration Technologies

Ingersoll Rand. Rotary Screw Air Compressors 5-15 hp (4-11 kw)

Distributed by: 2008 Ingersoll-Rand Company CCN IRITS

TrilliumSeries. Condenser

CO 2 transcritical FTE System Full Transcritical Efficiency

NEW HARRIS TEETER STORE SHOWCASES FIRST HILL PHOENIX SECOND NATURE COMPACT CHILLER UNITS IN NORTH AMERICA

Atlas Copco. Oil-injected Rotary Screw Compressors Variable Speed Drive + (7-15 kw/10-20 hp)

Commercial CO2 Refrigeration Systems. Guide for Subcritical and Transcritical CO2 Applications

compact BOOSTER RACK TRANSCRITICAL CO 2 Cooling capacity LT: from 2 to 130 kw Cooling capacity MT: from 20 to 300 kw

Ingersoll Rand 5-15 hp. Rotary Screw Compressors

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 7-37 VSD+ (7-37 kw/10-50 hp)

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

March 10, 2016 San Joaquin Valley RETA Meeting

Refrigerants Management & Retrofits. Mike Saunders & Randy Tebbe Emerson Climate Technologies

CO2 Supermarket System

Comparison Ammonia / Secondary Refrigerant System against Direct Evaporation of HCFCs /HFCs

Chillers and Refrigerants. Purpose of Today s Presentation. Agenda. GLHN Architects & Engineers, Inc. APPA Institute Session 322 EU

Natural Refrigerants.

RN SERIES REFRIGERATED COMPRESSED AIR DRYERS NON-CYCLING REFRIGERATEDERATED COMPRESSED AIR DRYERS SCFM

Guidance for Stationary Refrigeration & Air-Conditioning

Air conditioning 23XRV

GEA Blu chillers. GEA BluAstrum, GEA BluGenium, GEA BluAir: A new generation of compact ammonia chillers

MAYEKAWA MFG. CO., LTD Botan Koto-ku, Tokyo , JAPAN TEL:(81) FAX:(81)

NATURAL REFRIGERANT SYSTEMS

Fixed Speed Rotary Screw Compressors UP6 Series 4-11 kw (5-15 hp)

INDUSTRIAL REFRIGERATION. Position on refrigerant selection

Commercial CO 2 Refrigeration Systems

Nirvana. Cycling Refrigerated Dryers

Transcritical CO2 Bottle Cooler Development

Cold Energy Saver. Thermal Mass Cycling Refrigerated Air Dryers ( scfm)

The Current Path of Refrigerants

Low Charge ADX Ammonia. Presented by: Bruce Nelson, President, Colmac Coil Manufacturing Rick Watters, Vice President, AMS Mechanical Systems

Environmentally friendly systems for convenience stores

OACS Outdoor Air-Cooled Central Chillers

Energy Use in Refrigeration Systems

R717 ROMANIAN REFRIGERATION SYSTEMS ANALYSIS Professor Gratiela-Maria TARLEA, Ph.D

Air-cooled Screw Chillers Model RTAF G Process

1+ SEER. 25% COP boost possible. Most valves expand your refrigerant EcoFlow expands your options. with silent defrost.

Water (R718) The Safe & Natural Refrigerant. echiller Future Proof Refrigeration

Kirby CO 2 Evaporators

Energy Efficiency Considerations in Refrigeration Systems

Chapter 2. Alternatives to HCFCs and their Characteristics

Energy Performance of Low Charge NH3 Systems in Practice. Stefan S. Jensen

Choose the winning team. Heat transfer technology for industrial cooling and air conditioning

DEMONSTRATION OF ADVANCED INTEGRATED HVAC&R SYSTEMS IN A LOBLAWS SUPERMARKET IN CANADA

Atlas Copco Oil-injected Rotary Screw Compressors GA 15-22/GA /GA VSD (11-30 kw/15-40 hp)

Natural refrigerants - naturally efficient

PHASE-IN of natural refrigerants. Prof. Dr. Armin Hafner NTNU Norway

A Technical Introduction to Cool Thermal Energy Storage Commercial Applications

CRV Variable Operation Refrigeration Dryers scfm

Recommendations to retrofit positive existing installations running with HFCs (R404A & R507) RETROFIT POSITIVE & MEDIUM REFRIGERATING SYSTEMS

REFRIGERATION CYCLE Principles of Mechanical Refrigeration Level 2: Cycle Analysis

TRENDS IN RETAIL INDUSTRY REFRIGERATION & REVIEW OF EUROSHOP 2017 EXHIBITION

F Series - Refrigeration dryers

Refrigeration dryers DW 2-504

The natural solution for domestic refrigeration

Nirvana Cycling Refrigerated Dryers

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 7-75 VSD+ (7-75 kw/ hp)

Series. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost

Atlas Copco. Heat-of-compression rotary drum dryers ND series ( l/s, cfm)

Refrigerant and Energy Regulations Update

Evaluation of HCFC Alternative Refrigerants

Innovation for a Better & Greener Future

Chapter 10. Refrigeration and Heat Pump Systems

Scroll Chillers Transition from HCFC-22 to HFCs

CO 2. ECO Water Heaters. Energy efficient and environmentally friendly water and space heating. SANYO Air Conditioners. The natural choice.

Trailblazer air cooled scroll chillers

All Chiller Products. Water Cooled and Air Cooled Modular Chillers Available in 208, 230, 460 & 575 Volts Application Ranges from 30 to 1,000 Tons

Mechanical Systems Mechanical Systems

CHAPTER 1 INTRODUCTION

ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming

600-10,000 scfm AES Series. AES Series Energy Saving. Refrigerated Air Dryer ,000 scfm. Front Page

Rotary Screw Compressors R-Series 4-11 kw (5-15 hp) Fixed and Variable Speed Drives

DuPont Refrigerants. John McCormack Business Manager DuPont Chemicals and Fluoroproducts. R22 market and the ISCEON retrofit options

The analysis proceeded by adopting the ASHRAE guideline for conventional HVAC chiller applications. This guideline is summarized in Table II.

LEWA Plunger pumps. For high hydraulic power.

Winter sports fun all year round, thanks to natural refrigerants

Fixed and Variable Speed Rotary Screw Compressors R-Series 4-11 kw (5-15 hp)

OIL-INJECTED ROTARY SCREW COMPRESSORS GX 2-7 EP G 7-15 EL

86 C freezers. New Benchmark. New Brunswick sets the standard for extraordinary freezer quality, support, and energy savings

Rotary Screw Compressors UP5 Series kw

REDUCING AMMONIA REFRIGERANT CHARGE IN SKATING RINK REFRIGERATION SYSTEMS

L07 - L22. Oil Injected Rotary Screw Compressors. Intelligent Air Technology

PRESSURE-ENTHALPY CHARTS AND THEIR USE By: Dr. Ralph C. Downing E.I. du Pont de Nemours & Co., Inc. Freon Products Division

BOGE AIR. THE AIR TO WORK. Refrigerant Dryers RA Series

A Complete Line Of Remote Rack Refrigeration Systems

Transcription:

The Hillphoenix name is synonymous with innovative, sustainable and extremely efficient refrigeration systems in a variety of business segments. While much of the company s reputation has been built as the primary choice in the Retail Supermarket category, Hillphoenix brings identical and considerable benefits to industrial refrigeration. Cold Storage, Industrial Refrigeration, Pharma and even Ice Rinks are all prime markets for the Hillphoenix expertise with DX and CO 2 refrigeration systems. No other refrigeration systems supplier can match the years of significant investment in R&D, the commitment to - flexible and custom design and the sheer number of solution options available underneath the Hillphoenix name.

Inside the Advansor CO 2 Booster System 6 5 The Advansor CO 2 booster system is defined as a trans-critical CO 2 system that provides both low- and medium-temperature refrigeration evaporators without relying on any other refrigerants. Here s how it works. 7 1 4 2 3 The cooling cycle begins with liquid CO 2 in the flash tank (receiver) (1). A network of pipes distributes the liquid to evaporators specially-designed for optimum operation in CO 2 booster systems. Electronic expansion valves (EEVs) are in place to control the flow of CO 2 into those evaporators (2)...Suction gas from the low-temperature evaporators returns to the rack and is compressed by the subcritical compressors to the pressure of the medium-temperature evaporators (3)...Suction gas from the medium-temperature evaporators returns to the rack and is combined with discharge gas from the low-temperature compressors and flash gas exiting the flash tank via the flash gas bypass valve (4)...This mixture enters the trans-critical compressors and is compressed to high pressure (5)...From there it is sent to the gas cooler where it is cooled to near ambient temperature in cooler weather, the CO 2 in the gas cooler condenses similar to conventional systems (6)...From the gas cooler, the CO 2 enters the high-pressure control valve where it is expanded back to subcritical pressures (7)...The CO 2 then enters the flash tank where it is separated into liquid and gas and the cycle begins again. For more information, contact us at: 770.285.3264 or Hillphoenix.com.

Inside the Advansor CO 2 Booster System 6 5 1 7 4 3 2

The Advansor CO 2 Booster System Enter CO 2 and Advansor by Hillphoenix. The Advansor Trans-critical booster system utilizes only one refrigerant the abundantly available, completely sustainable and economical CO 2. CO 2 is neither flammable nor toxic, making it ideal in terms of installation and system operation. Further, all Advansor booster systems are carefully manufactured to achieve optimal, safe, and service-friendly operation. State-of-the-art oil control, flash gas control, and pressure regulation systems make Advansor the most reliable and energy-efficient CO 2 refrigeration system on the market. Industrial Refrigeration systems have traditionally relied upon two refrigeration coolant technologies for decades. Ammonia has been the de facto standard for very large systems. Synthetic halocarbon refrigerants in use since the 1920s account for the rest. Regulations put in place to control the usage of both ammonia for its safety issues and the synthetics for their ozone depletion and global warming concerns have made the two coolant technologies extremely problematic. Business owners preparing to invest in a new refrigeration system must weigh all factors that impact their Total Cost of Ownership. Environmental impact and compliance or lack of compliance must loom large in those considerations. Supplier credibility is just as important and Hillphoenix has over a decade of experience and over 1500 trans-critical CO 2 systems installed worldwide. Hillphoenix closes the deal with a commitment to provide guidance and training in the newest innovations and installation and maintenance best practices through the Hillphoenix Learning Center.

Advansor at a glance Benefits Features Options Easier to operate than NH 3 systems. More cost-efficient TCO (total cost of ownership) than NH 3 in terms of equipment, installation, and service. Quick and simple commissioning. CO 2 in cold storage areas and processing areas is safer for product and people than NH 3. Systems are lighter weight and command a smaller footprint. 100% HFC free. High quality heat reclaim opportunities for under-floor heating and process heating loads. More efficient than HFC refrigerant systems in certain climates. Variable speed drives on lead medium-temp compressor. Air-cooled and adiabatic gas coolers with variable speed fans as an option. Electronic-controlled high pressure and flash gas bypass valves ensure optimal performance in all ambient conditions. Simple electronic oil management system ensures adequate lubrication for longer compressor life. Reliable, proven reciprocating compressors. Electronic expansion valves provide efficient evaporator operation. Can be packaged in Hillphoenix Paratemp or Weatherpac units with factory-piped gas cooler on common frame. De-superheater on low temperature compressor discharge for increased energy efficiency. Variable frequency drives on low-temperature compressors for increased energy efficiency.

The next logical step in natural refrigerant solutions A little ammonia tons of cooling. Ammonia is the most environmentally friendly natural refrigerant with a GWP (Global Warming Potential) and ODP (Ozone Depleting Potential) right at zero. Yet, the inherent hazards of using ammonia to cool have resulted in a tangle of regulatory liability and personal safety concerns until now. The Hillphoenix NXTCOLD technology has solved the compliance and hazard issues by creating an ultra low charge ammonia industrial refrigeration system ultra low as in 8 ounces of ammonia per ton! in systems from 5 tons up to 150 tons. More efficiency More savings. The NXTCOLD system is equal to or even more energy efficient than a central engine room system for several reasons. The use of close-coupled components eliminates a host of potential trouble spots. The system has no liquid refrigerant pump which keeps it simpler and more economical. And NXTCOLD systems keep pressure constant without pressure drops that can compromise compressor capacity and increase power usage. Ammonia s superior heat transfer properties add to the savings because it allows equipment to have smaller heat transfer areas which lowers plant construction costs and reduces operating costs!

The next logical step in natural refrigerant solutions 770-285-3264 email industrial@hillphoenix.com www.hillphoenix.com ERIC is the key. ERIC Electronic Refrigerant Injection Control is a patented technology developed for freezers, blast freezers, coolers and temperature controlled environments that reduces the amount of ammonia necessary in a system to only 8 ounces of ammonia per ton! This ultra-low-charge eases regulatory liability and personal safety concerns as well as oversight and staffing needs. A ton of choices. NXTCold refrigeration systems come in four distinct series from 5 to 150 tons. They are an extremely cost-effective solution for high and low temp applications. With the looming phase-out of HFC and HCFC systems, the timing is perfect. For new construction, for increasing refrigeration capacity, or to simply improve system performance and reduce operating costs, an ultra-low-charge NXTCOLD ammonia refrigeration system is an ideal choice. Series: 1ST-1F 1ST-2F 1ST-3F 1ST-4F 1ST-5F Capacity Range: 5 to 20 TR 10 to 40 TR 30 to 90 TR 50 to 120 TR 70 to 160 TR Ammonia Charge: 40 to 160 oz 160 to 320 oz 240 to 800 oz 400 to 1,200 oz 560 to 1,280 oz *Type A Footprint (8-6 ): 7-3 x 16-6 7-3 x 20-0 7-3 x 23-6 7-3 x 27-0 N/A Type B Footprint (9-6 ): N/A 11-11 x 23-6 11-11 x 27-0 11-11 x 31-0 11-11 x 35-0 Lowest Capacity Weight: 7,500 lbs 10,000 lbs 12,500 lbs 15,000 lbs 22,500 lbs Highest Capacity Weight: 15,000 lbs 20,000 lbs 25,000 lbs 30,000 lbs 37500 lbs Room Temperature Application Range -35 to 50 F Convertible Configuration Available x x x x x * Type A Footprint ships in a standard container

CO 2 Cascade Systems A Cascade of Benefits! Parallel Rack Technology Doubles Down on Efficiency The Hillphoenix CO 2 Cascade refrigeration product line combines one of nature s most abundant elements CO 2 with a secondary coolant of choice (ammonia, glycol, HFC etc.) in a parallel rack design that increases redundant capacity and refrigeration system availability. Hillphoenix has spent years developing and refining the compressor technology employed in the CO 2 Cascade systems. The compressors are durable and reliable and will deliver long, uninterrupted operations. But when service is required, the parallel rack design has a distinct, built-in advantage. Multiple compressors linked in parallel eliminate the costly inconvenience of downtime scheduled or otherwise because one compressor can be isolated for maintenance while the others in the system pick up the slack by adjusting their output to match load demands. There will be no interruption or degradation of service whatsoever. Maintenance is a breeze and serviceability enhanced when compressors are linked in a parallel rack configuration.

CO 2 Cascade Systems A Cascade of Benefits! 770-285-3264 email industrial@hillphoenix.com www.hillphoenix.com Save Energy. Compressors in a Hillphoenix Cascade System are carefully selected to match refrigeration loads precisely so that only a minimal amount of electrical energy will be required at any one time. Save Space. Hillphoenix designs its parallel rack systems with integrated power and control enclosures pre-installed which results in a more compact footprint. As a result, valuable floor space is freed up that can be made available for other uses. Save Hassle. Every parallel rack assembly is configured, built, installed and tested at the factory before it is shipped. The system is mounted on a skid and the entire, one-piece assembly is shipped right to the job site without hassles or hiccups. Multiple Applications End users concerned with reducing the overall operating costs as well as the amounts of refrigerant required by the systems in their cold storage, process cooling, biopharma and ice rink applications will find that benefits and peace of mind go hand-in-hand with a CO 2 Cascade parallel rack system from Hillphoenix. CO 2 Cascade Systems Rack Specifications Number of Compressors 2 2 2 3 3 3 4 4 Capacity (Tons of refrigeration) 4 23 43 65 79 98 115 144 Total Brake Horsepower 4 20 36 53 65 81 95 119 L x W x H 96 x 48 x 80 96 x 48 x 80 96 x 48 x 80 120 x 48 x 80 120 x 48 x 80 120 x 48 x 80 144 x 48 x 80 144 x 48 x 80 Weight 1577 1785 1927 2174 2304 2461 2681 2500 Operating Conditions - R-744 Refrigerant, -20 F saturated suction temp, 20 F condensing temperature, no sub cooling