Electronic Crimping Tools

Similar documents
Electronic Crimping Tools REF Operation Guide

Notices. Safety Notices. 2 Restek Corporation

Notices. 2 Restek Corporation. Safety Notices

Agilent Electronic Crimping and Decapping Tools Operating Guide. Agilent Technologies

Electronic Crimping Tools Operations Guide. Contents

Vials and caps from. Crimping tools. Manual crimping tools Ergonomic Standard Electronic crimping tools Battery-powered High power crimping tool

Mini-Rooter Operating Instructions

D100S-T420 Portable Service Hose Crimpers

Operating instructions

PRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO:

MC2000 OPERATING AND CALIBRATION INSTRUCTIONS

Tempest TP420/180 Electric Pressure Washer

UNIQUE USER FRIENDLY MICROMETER STYLE ADJUSTMENT

DOC JAN06 LT 200

ASG EZ-9000GR Tape Dispenser User Manual ASG #66136

INSTALLATION INSTRUCTIONS ESS 7.0

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

Paper Shredder. Installation & User Instructions Please keep for future reference 913/0153

FastGene Plate Centrifuge. Instruction Manual. Catalog No. NG

JS. Bosch Remote Control

Instruction Manual. Model AccuPlate Hotplate AccuPlate Stirrers AccuPlate Hotplate Stirrer 12/10 CLS-EQ-LHP01REV

IMPORTANT Warnings and Safeguards

FEB 15 Rev C

Vacu-Mixer. Operating Instructions

OPERATIONS MANUAL. Hotplate Stirrer/Hotplate/Magnetic Stirrer Model HTS-1003/HTP-1002/MGS Certified

ASSEMBLY AND OPERATING INSTRUCTIONS PADDLE MIXER. FOX Model F V / 110V

TTK 75 E OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75E-TC-002-EN

Operating Manual Bathroom Balance

A4 Laminator. Installation & User Instructions Please keep for future reference 908/6197

COMPACT AND LIGHTWEIGHT FOR OUTDOOR CLEANING

Ireland. Australia. New Zealand

Translation of the original instructions. Type: MKR 600

IMPORTANT SAFETY INSTRUCTIONS

Operating instructions

A-MIP 100 Installation and Operating Manual

Operating and Maintenance Instructions

Silent TS. Nr / Ideas for dental technology / A. Made in Germany

Hydraulic Crimping Systems

RX550i Electric Pressure Washer

M O D E L G W T - 202P OPERATIONS MANUAL TABLE OF CONTENTS

User Manual. GPD 3000 e. gas detector

PORTABLE AIR CONDITIONER

Kitchen Appliance Lift INSTRUCTION MANUAL

Installation and Operation Manual

Bose Home Theater Speakers. Owner s Guide

DLC Instruction Manual. Light Curing Machine MODEL. Table of Contents

Installation and operation manual

Operating instructions

ProAction. Paper Shredder. Installation & User Instructions Please keep for future reference 903/1537

L1L2L3. 99 Washington Street Melrose, MA Phone Toll Free Visit us at

Grain crusher Universal. Purpose: This machine is designed for the crushing of grain in agricultural operation.

FAILURE TO ADHERE TO THESE WARNINGS CAN RESULT IN FIRE, SERIOUS INJURY, ELECTRICAL SHOCK AND/OR DEATH. Technical Service

Operator's Manual. LIGHTNING 2 Laser Detector

Instruction Manual. For All Corning Hot Plates, Stirrers, Stirrer/Hot Plates with Digital Displays, and External Temperature Controller (6795PR)

FEB 16 Rev T

FLAMA USER S AND INSTALLER S MANUAL

Instruction Book for HD Punch Machines

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

WELCOME IMPORTANT SAFEGUARDS

Owner s Manual Super-Slim Four-Way Cassette

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets with screw connection (16/32 A)

UNIQUE USER FRIENDLY MICROMETER STYLE ADJUSTMENT

ACQUITY UPLC HT Column Heater Instructions

WIRELESS THERMO-HYGROMETER Instructions manual Cat. No. WS9070IT+

Single- Action Double- Action

24 & 30 Drum Fan. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

AUSTRALIA PAD1200-XE NEW ZEALAND

Portable Washing Machine GPW-6

DESIGNED FOR HEAVY DUTY, OUTDOOR CLEANING

Package Contents. Dry Block Heater Power Cord Instruction manual Warranty Card. Serial Number: Date of Purchase: Supplier: Table of Contents

GE Healthcare. Mixer M-925. Instructions

Ireland. Australia. New Zealand

e Bath Fan with Light User s Guide

OPERATING MANUAL MODEL NO MODEL NO AND MODEL NO MODEL NO

SimpleVIS Viscometer Reference Guide P

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

Installation and Operation Manual CLEARVIEW DAY COVER CAUTION: To view a video scan the QR code above

PORTABLE DEHUMIDIFIER

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets QUICK-CONNECT (63 A)

TA-12. Tabbing System USER'S GUIDE

Electronic Thermostat With RF

MAR 16 Rev C

1F60-22 INSTALLATION & OPERATING MANUAL SETBACK THERMOSTAT. Homeowner: Save this booklet for future use!

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

INSTALLATION & OPERATION MANUAL

This section applies to the use of cord- and plug-connected equipment, including cord sets (extension cords).

e Bath Fan with Light User s Guide

INSTRUCTION- AND MAINTENANCE MANUAL FOR ELECTROMAGNETIC AIR PUMP JDK-60, JDK-80, JDK-100, JDK-120

PRO 2000i LOW LEVEL DEPOSITOR

Ireland Australia New Zealand

Operating instructions

Installation, Operating and Servicing Instructions

Operating Instructions

OPERATING & SERVICE PARTS MANUAL 700ES ENERGY SMART WRAPPER SERIES B

English... 5 Čeština Slovenčina Magyarul Polski Русский... 85

TTK 70 S OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK70S-TC-001-EN

Remote alarm case VENTIremote alarm 10 m WM VENTIremote alarm 30 m WM Device description and instructions for use

Version 1.6. Operating instructions HYDROMETTE BL COMPACT TF 2. Hydromette BL Compact TF 2

Operating instructions

THANK YOU. For purchasing the VMI HYBRID TM

Transcription:

Electronic Crimping Tools REF 735700 Electronic high power crimping tool with power supply and separately available crimping/decapping heads (also suitable for magnetic/bimetal crimp caps) Operation Guide

Notices Safety Notices MACHEREY-NAGEL GmbH & Co. KG Part No. 735EGUIDE-HP Rev. A Printed in USA Mar - 2012 MACHEREY-NAGEL GmbH & Co. KG Düren, Germany A CAUTION notice warns of a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met. WARNING A WARNING notice warns of a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met. Declaration of Conformity These instruments conform to the following directives: 2006/95/EC Low-Voltage Directive 2004/108/EC - EMV Directive 2006/42/EC - Machinery Directive Recycling Disposal in accordance with EU Directive 2002/96/CE. In compliance with local and national legal regulations (EU Directive 2002/96/CE), the MACHEREY-NAGEL company disposes old instruments free of charge. Note: With effect from August 2005, disposal using public waste disposal facilities is no longer permitted. In the case of disposal, please contact your MACHEREY-NAGEL representative. Sound Pressure Sound pressure LpA = 79 db(a) 2 MACHEREY-NAGEL GmbH & Co. KG

Electronic Crimping Tool 735700 Operations Guide Contents Warnings, Intended Use, Limits 4 Description 5 Setup 5 Operation 5 Storage 8 Fault Conditions and Display Codes 9 Maintenance/Repair 9 Troubleshooting 10 Appendix A - Accessory: Stand for Electronic Crimping Tools 11 This operation manual applies to the following products: REF Electronic High Power Crimping Tool 735700 Related Items REF Stand for electronic crimping tools 735501 11 mm Crimping Head 735711 20 mm Crimping Head 735720 11 mm Decapping Head 735811 20 mm Decapping Head 735820 Electronic Crimping Tool 735700 3

Warnings Remember to wear safety glasses when crimping or decapping. The crimper or decapper jaws can pinch severely. Only change jaws after the power supply has been disconnected or the tool has been locked. Never insert fingers into the crimping tool jaws. Use only the 12 volt DC Power Supply supplied with the crimping tool. Intended Use The Electronic High Power Crimping Tool is intended for use in a laboratory environment. Prohibited Use All other uses are prohibited. Limits Temperature 15ºC to 35ºC Humidity not more than 75% Pressure 0.75 to 1 bar 4 MACHEREY-NAGEL GmbH & Co. KG

Description The Electronic High Power Crimping Tool 735700 can be used to crimp and decap standard crimp caps on laboratory sample vials. In contrast to the battery operated electronic crimping tools this one can also crimp/decap magnetic/bimetal crimp caps without any problems. A variety of jaw sets can be used to accommodate the most popular sizes. Crimping Tool Setup Please read through this entire manual to familiarize yourself with the operation of the tool before proceeding. Use the same degree of care as you would with any precision instrument. Remove the tool, power supply, cable and CD from the shipping container. Inspect all components of the tool carefully. If there is any visible damage contact your supplier immediately. Operation Connecting the Power Supply Connect the 12 volt DC supply to the mains with the power cord provided and also plug it into the connector on top of the crimping tool. After power up the right jaw set type may be selected with the and buttons while the display is blinking. Electronic Crimping Tool 735700 5

Locking the Crimping Tool If the power is connected, the crimping tool must be locked before changing jaw sets. To lock the tool hold the or button for 2 seconds. The display will show Off and then flash with the last jaw set code in use. The go-button will not start the tool when it is locked. Selecting or Changing a Jaw Set while Power is Connected First lock the tool by holding the or button for 2 seconds. Insert the jaw set into the bushing at the bottom of the tool. Push up against the spring load and then twist until the set locks into position. To remove a jaw set, push the button on the outside of the supporting cup and rotate. While the jaw set code is flashing, use the button to choose the size and the button to select c for crimper or d for decapper. When the selection is complete, press and hold the go-button 2 seconds to confirm the selection. The display will show On momentarily and then enter operating mode. The last setting for a given jaw set is reloaded when it is selected for use. Selecting the wrong jaw set can cause the crimping tool to attempt to travel too far, creating an Er1 (Stall) condition. See page 9. 6 MACHEREY-NAGEL GmbH & Co. KG

Selecting Compatible Vials, Caps and Seals Standard aluminum crimp caps or steel (magnetic) caps or two-part caps with aluminum sides and magnetic tops (bimetal caps) together with seals of standard size and thickness are appropriate. 20 mm caps with very thin seals cannot be removed with the 20 mm decapper jaw set. Adjusting the Tool for Crimping Jaws The electronic crimping tools must be adjusted for the vials, caps and seals that need to be crimped. The and adjustment buttons on the top of the crimping tool set a stop position for the motor that drives the tool. Pressing either button one time displays the current setting. Pressing again will change the setting. The numerical setting of the crimping tool sets a stop position that determines the amount of compression of the cap and is very accurate. There may be some drifting in the setting over time due to stretching or wearing-in of components of the new tool, but generally the reproducibility of the crimp is as good as the consistency of the vials and seals. Some adjustment for different lots of caps and seals is to be expected. Select 5 or so vials, caps and seals for the purpose of setting the crimp. Place the seal and cap on the vial and rest the tool on top of the cap. Squeeze the go-button lightly to engage the motor. This button must be held down until the crimp is complete. If the button is released early, the tool will retract and display the error code Er0. An error code Er1 means that the tool stalled it was not able to deliver enough power to reach the position requested in the setting. Check the crimped vial for satisfactory cap form as an indicator for correct crimping as well as for tightness. If the cap spins easily, press the button two or three times. Try the new setting with a new vial and cap. Crimping the same vial two times will not give the same results and sometimes will result in vial breakage. See the section on Troubleshooting for more information. Good Crimp Too Tight Too Loose Electronic Crimping Tool 735700 7

Adjusting the Tool for Decapping Jaws The adjustment is not very important when decapping. The factory settings for the decapper jaw sets are probably satisfactory. The 11 mm and 13 mm decapper jaws work by closing the jaws around the neck of the vial and stripping the cap off. For the 11 mm and 13 mm decapper jaw sets to work, the glass vial must be strong enough to resist the force applied by the tool. In the case of inferior or soft glass, or if a vial is reused, the lip of the vial may break during cap removal. To adjust the tool for the11 mm and 13 mm decapper jaw set, make sure that the stroke is long enough to remove the cap. Each step for the decapper jaw set is 5 units. The 20 mm decapper jaw set works by pinching the sides of the cap with the decapper jaws and pushing out the glass. The pinching action starts to pull the cap off, and the force of the tool does the rest of the work. To adjust the tool for the 20 mm decapper jaw set, just make sure that the stroke is long enough to remove the cap. Saving Multiple Programs for a Jaw Set If you use more than one type of cap and seal of the same size, you may decide to store multiple settings. To do this, hold the and buttons down together for two seconds, until the current program number is displayed. Then use the and buttons to scroll through the programs (Pr1 Pr9 ). Programs displaying --- are not in use. After choosing a program, press the go-button to select it. The program setting can be adjusted at that point. To remove a program, use the button until --- is displayed. (Hold a button to scroll rapidly). Unless multiple programs are in use, they will not appear on the display. Reset Pressing the reset button is the same as disconnecting and reconnecting power. After selecting the jaw set and pressing the go-button the crimping tool retracts to the top zero position. Reset button Go-button Storage Remove power from the tool to prevent accidental cycling before storing. 8 MACHEREY-NAGEL GmbH & Co. KG

Fault Conditions Major and minor faults are identified on the LED display, normally after a crimp cycle. Fault Code Possible Cause Recommendation Er0 Er1 Er9 Early go-button release the tool retracted before completing cycle. Stall condition Crimp setting is too high. Motor drive failure Other Display Codes Try again, making sure to hold the button down until the tool is returning to the home position. Adjust tool to a lower setting. See Maintenance / Repair section for contact information and for warranty and repair service information. Display Description Comment xx d (e.g. 11d ) xx decapper jaw set selected See page 6. xx c (e.g. 20c) xx crimper jaw set selected See page 6. xx (e.g. 38 ) The tool setting is 38 Prx (e.g. Pr0) Off On Program x for the given jaw set. Tool has been locked. Tool is returning to operation. Press the Go-button for 2 seconds to resume operation. Maintenance and Repair General Maintenance The electronic crimping tools do not contain user serviceable parts. Cleaning Disconnect power before cleaning! The crimping tool may not be immersed in water or solvent. The outside of the case may be cleaned with an ordinary detergent and wiped off with a damp rag. Care should be taken not to get the electronics wet. Avoid permitting metal parts of the crimping tool to come into contact with corrosive material during use. If they do, try to wipe them clean with a suitable mild neutralizing solution. Electronic Crimping Tool 735700 9

Troubleshooting Condition Possible Cause Recommendation Side of cap is indented. Seal is deformed in hole. Cap spins easily. Crimping is inconsistent. Some vials are good and some are not. 11 mm or 13 mm decapper leaves caps hanging on vials Motor does not come on or moves in one direction only. No activity when power supply is connected. Crimp setting is too high. The crimp is too tight. Crimp setting is too low. The crimp is too loose. Vials, caps or seals are inconsistent. Electronic failure in crimper. Decapper adjustment is too low. Jaws are worn or broken. Drive circuit failure. Power supply failure Adjust tool to a lower setting by pressing the button. Adjust tool to a higher setting by pressing the button. Check crimper by using some standard, approved, vials, caps and seals. Visit www.mn-net.com for support information. Adjust the decapper to a higher setting by pressing the button. The decapper will have to be replaced or repaired. Visit www.mn-net.com for support information. Visit www.mn-net.com for support information. Visit www.mn-net.com for support information. (Power supply must be replaced). Support and Repair If the crimping tool is still in the warranty period, contact your dealer for support. If the warranty period has expired, please visit www.mn-net.com for information about the crimper repair service. 10 MACHEREY-NAGEL GmbH & Co. KG

Appendix A 1 Accessory: Stand for Electronic Crimping Tools (735501) 2 3 4 5 Electronic Crimping Tool 735700 11

Further Information For further information on autosampler vials and caps, please visit our website on www.mn-net.com/vials or check our specialized brochure. Contact MACHEREY-NAGEL GmbH & Co. KG Neumann-Neander-Str. 6-8 D-52355 Düren Germany Tel.: +49 2421 969-0 Fax: +49 2421 969-199 E-mail : sales@mn-net.com Internet : www.mn-net.com