Operating Instructions for Air-Flow Monitor. Model: LPS-P

Similar documents
Operating Instructions for Rotor flow Indicator. Model: DKF

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

! WARNING. Before using product, read and understand instructions.

! WARNING. Before using product, read and understand instructions.

! WARNING. Before using product, read and understand instructions.

Snifter ATEX22 VERSION. User Manual. Distributor

INSTRUCTIONS CertoClav EL

USER MANUAL AND TECHNICAL MANUAL

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

L1L2L3. 99 Washington Street Melrose, MA Phone Toll Free Visit us at

Temperature Sensor TRG Original Installation Instructions English

OPTISENS TUR 2000 Technical Datasheet

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

Operating Instructions

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

WHA 3000P Hot Air Station

Owner Instructions Original Instructions Warning! Read instructions before using the machine. LoLine NLL 332 NLL 415

GESTRA Steam Systems BK 15. Installation Instructions Steam Trap BK 15, DN 40-50

INSTRUCTION MANUAL (ATEX / IECEx)

SIKA VK300 OR VK325 SERIES FLOW SWITCH Operating Manual

Instructions for the fan motor control system, SILVER C

Role of CE Marking in the Placing on the Market of Electronic Components

F17W44_MFB_F_EN INSTALLATION INSTRUCTIONS

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

Sintrol Snifter A1+ Manual. Version 1.2.2

Electro Controls. Flow WattsIndustries.co.uk

+ English + 1. Safety warnings

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Advance Optima Continuous Gas Analyzers AO2060-Caldos15, -Caldos17, -Magnos106, -Uras14 Category 2G Analyzer Modules

OO Measuring range from bar rel. OO Large selection of pressure sensors. OO Automatic sensor recognition

INSTRUCTION MANUAL. LOW SPEED CENTRIFUGE ScanSpeed MiniVac And ScanSpeed MaxiVac. Revision : 01 Date : Cat. No. :

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

HTD. High Temperature Non-Cycling Refrigerated Compressed Air Dryers. Operation & Maintenance Manual. MODELS HTD 21 thru HTD 100

HOT 2000 USER MANUAL. Version 3.1. This manual shall be read in its entirety before using the machine.

OPTIBAR DP 7060 Supplementary Instructions

OH720, OP720, HI720, HI722

1592P01. for liquids in piping DN

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

The ETA route to CE marking from the perspective of the European Commission. G. Katsarakis (DG GROW/C.1)

Instruction Manual. Model AccuPlate Hotplate AccuPlate Stirrers AccuPlate Hotplate Stirrer 12/10 CLS-EQ-LHP01REV

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

Operating Instructions

Thermo-Sealer. Manual Heat Sealer. User Manual

Instruction Manual Mini Hotplate Mini Stirrer Mini Hotplate-Stirrer Mini Auto Stirrer Mini Fixed Temperature Hotplate

METROTEC Systeme zur Messung und Regelung von Sauerstoff

Snifter. User Manual. Distributor

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

ExPolar Heating System

BESB Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

DOMEKT ReGO 400VE(W)-B Series Air Handling Units Installation and Maintenance Service Manual

MK 45-1 MK 45-2 MK 45 A-1 MK 45 A-2

Frost Protection Thermostat

Operating Instruction Centrifugal fans without scroll (Translation of the Original) BA-RLE-AC /2014 RLE RLA

Multipoint temperature sensor

LED Sensor Floodlight AZPOSE XL-S

Adsorption dryers PDAD

Instruction Manual Captive Air Level Control. Model NLP

Instruction Manual M6627 / Version 7.4. Slide Drying Bench MH6616 MH6616X1

Rosemount 1595 Conditioning Orifice Plate

Betriebsanleitung / Operation manual. Druckwächtereinheit QUINGUARD / Pressurization Controller QUINGUARD

Operating Instructions UniTech Perfect

KHM800 Professional 800w haze machine

GESTRA Steam Systems BK 37 BK 28 BK 29. Installation Instructions Steam Trap BK 37, BK 28, BK 29 BK 37 ASME, BK 28 ASME, BK 29 ASME

OPTIBAR P 1010/2010 C Supplementary instructions

Vacuum cleaner Instruction manual

IH 025 VOLCANO. Portable Induction Heater. smart mounting

SAFETY AND OPERATING MANUAL

Instruction Manual. CAT 100 & CAT 200 Continuous Analyzer Transmitter Addendum for Hazardous Area Applications. 3 rd Edition 05/2007

GESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45

Output module (230 V)

DEVIATING VALVES ART K063

Robotic Mowers (battery powered and charging station connected to electric mains or low voltage supply)

HOT 4000 USER MANUAL. Version 2.1. This manual shall be read in its entirety before using the machine.

WIO200 Water In Oil measuring instrument

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

High Output Vacuum/Pressure Pump

Submersible Garden Pump USER'S MANUAL

Operating instructions for the radio heat detector GS412

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

Translation of the assembly instructions with operating instructions and technical appendix

TRG 5-53 TRG 5-54 TRG 5-55 TRG 5-57

INSTALLATION INSTRUCTIONS

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

INSTALLATION INSTRUCTIONS ESS 7.0

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

CE Unit is suitable for material transport. The transported gas may be up to 80 C.

VC-1, VC-1-SL, VC-2-L, VC-2-SL

PH1000T PH1500T PH2000T

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

Manual Page 1 of 8. Manual. Laboratory autoclave

Magnetic-Inductive Flow Velocity Sensor PIT. Device Description

Magnetic-Inductive Flow Velocity Sensor PIT. Installation and Operating Instructions

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

EUROPUMP ATEX Guideline Part II

VST Series. INAIL approved and calibrated safety valves. Technical Data Sheet. WattsIndustries.com

INSTALLATION FB T: +44 (0) F: +44 (0) E: W:

Transcription:

Operating Instructions for Air-Flow Monitor Model: LPS-P

1. Contents 1. Contents... 2 2. Note... 3 3. Regulation use... 3 4. Operating Principle... 3 5. Instrument Inspection... 4 6. Mechanical connection... 4 7. Electrical Connection... 5 8. Commissioning... 6 9. Technical Information... 7 10. Order Codes... 7 11. Maintenance... 7 12. Dimensions... 8 13. EU Declaration of Conformance... 9 Manufactured and sold by: Kobold Messring GmbH Nordring 22-24 D-65719 Hofheim Tel.: +49(0)6192-2990 Fax: +49(0)6192-23398 E-Mail: info.de@kobold.com Internet: www.kobold.com Page 2 LPS-P K01/1116

2. Note Please read these operating instructions before unpacking and putting the unit into operation. Follow the instruction precisely as described herein. The devices are only to be used, maintained and serviced by persons familiar with these operating instructions and in accordance with local regulations applying to Health & Safety and prevention of accidents. By usage in machines, the measuring unit should be used only then when the machines fulfil the EC-machine guidelines. 3. Regulation use These units (type LPS) are employed in order to monitor the air-flow in air and environment industry. All these units are equipped with adjustable limit-contacts. Monitoring of fluids is suitable only for those gases and air, which would not attack the materials used in flow monitor. This air-flow monitor should not be used for monitoring of flammable and explosive gases. Material Combination Housing Galvanised base-plate /Cover (ABS) Paddle St. Steel (AISI) Paddle arm Brass (Ms 58) Connection- plate Galvanised iron Flat Gasket Flexoid Switch Off/On (adjustable) Switch-off values (min) 1.5 m / sec. (max) 8.0 m / sec. (with shortened paddle) Switch-on values (min) 2.5 m / sec. (max) 9.2 m / sec. (with shortened paddle) 4. Operating Principle The air flow being controlled presses against the paddle, which is mechanically linked to a dust-tight changeover microswitch. The latter will signal whether or not the minimum or maximum preset air flow exists. The switching point is adjustable over a wide range of values. LPS-P K01/1116 Page 3

5. Instrument Inspection Instruments are checked before dispatch and should arrive in perfect condition. In case of damage, please inform your local Kobold office or if you had the parcel transport your parcel service / forwarding agent immediately, since they are responsible for damages during transit. Should the damage to a device be visible, we recommend a thorough inspection of the delivery packing. Scope of delivery: Air-Flow Monitor Model: LPS-P Flat Gasket Operating Instructions 6. Mechanical connection Before mounting Please ensure that the actual flow value remains within the switching range of the unit. Make sure that the permitted max. operational pressure and temperature limits of this unit are not exceeded. Please ensure a minimum run inner pipe diameter of 5 x D upstream and downstream of the switch. Assembly Drill a hole and a slit in your air-channel as shown in the adjacent drawing. Fix the flow-monitor over the air-channel and secure it with 4 metal screws (D=3.5 mm). The paddle can also be mounted after the installation, it is then sufficient to drill a 20 mm diameter hole. Sealing is carried out by means of supplied flat gasket. Mounting of this unit is position independent. The affixed arrow sign on housing must point in the direction of the flow. The upper part of the flow-monitor must be vertical with respect to the pipe axis. With vertical mounting, the switching point must be adjusted in order to compensate for the paddle-weight. For gases containing dust particles, the flow monitor must be positioned in such a way that no dust particles can deposit inside the connection head (e.g. mounting on the upper side of the air-channel). Page 4 LPS-P K01/1116

7. Electrical Connection Please ensure that the voltage as well as the current values of your power supply does not exceed the permitted values specified for the flow monitor. Erde Before making connections, be assured that the ground power supply lines are not active. Remove the housing of the flow monitor by loosening 4 screws Make connections to the flow monitor as shown in the adjoining figure. rot red blau blue weiß white After making connections between external units and the limit-contact, the unit is ready for operation. LPS-P K01/1116 Page 5

8. Commissioning These units are supplied along with an adjustable micro-switch. The contact is change-over type, which, depending on connections, may be used as normallyclosed or normally-open switch. These units are factory-set at a switch-off value of 1.5 m / sec. A higher "switch-off" value is set by rotating the range-screw in the clockwise direction. In case a switching value over 5 m / sec. is desired, then the paddle must be truncated at the marked position. By paddle-truncation, the factory-set value changes to 2.5 m/sec. Page 6 LPS-P K01/1116

9. Technical Information Max. Switching Current: 15 (8) A Max. Switching Voltage: 24-250 VAC Protection Cat.: IP 65 (from external channel) Max. Medium Temp.: +85 C Ambient Temperature: -40 C...+85 C 10. Order Codes Description Air-flow indicator Order number LPS-1100P 11. Maintenance In case, the medium to be measured is not polluted, LPS-P flow-monitor is regarded as maintenance-free. Otherwise, presence of large-size dust-particles may lead to the jamming of paddle arm. Depending upon the degree of pollution, a routine check after regular intervals is recommended. LPS-P K01/1116 Page 7

12. Dimensions Page 8 LPS-P K01/1116

13. EU Declaration of Conformance We, KOBOLD Messring GmbH, Hofheim-Ts, Germany, declare under our sole responsibility that the product: Air-Flow Monitor Model: LPS-P to which this declaration relates is in conformity with the standards noted below: EN 60730-2-15:2010 Automatic electrical controls for household and similar use - Part 2-15: Particular requirements for automatic electrical air flow, water flow and water level sensing controls Also the following EC guidelines are fulfilled: 2014/30/EU 2014/35/EU 2011/65/EU EMC Directive Low Voltage Directive RoHS (category 9) industrial monitoring and control instruments, compliant, no CE-marking for the transitional period until 2017 Hofheim, 01. Dec. 2016 H. Peters M. Wenzel General Manager Proxy Holder LPS-P K01/1116 Page 9