Similar documents
carbon monoxide alarms

putting safety first natural gas

Carbon Monoxide Safety Information

Gas Safety. Information for homeowners. orbit.org.uk

Carbon Monoxide Safety

Gas safety. Information for homeowners. orbit.org.uk

Carbon Monoxide Alarm

Comhshaol, Pobal agus Rialtas Áitiúil Environment, Community and Local Government. Fire safety at home

Specification and Electrical Contractor Guide

Carbon Monoxide Room Alarm Installation and User Guide Part No:

Technical Bulletin 008 (Edition 2) CIP-RACL Developed by Industry

Special Edition. Routt County Office of Emergency Management. Carbon Monoxide The Silent Killer. What is Carbon Monoxide (CO)?

OWNER GUIDE. Sunfire II Radiant. Radiant / Convector Gas Fire. Model 347 (G. C. Number )

Ventilation and Hand Dryers

OWNER GUIDE. Model 739 OPEN DECORATIVE GAS FIRE. (GC No )

Carbon Monoxide Detectors. What is carbon monoxide?

PROTECTING AGAINST CARBON MONOXIDE. Questions and Answers about Carbon Monoxide (CO) and CO Alarms

LOMBARD FIRE DEPARTMENT ILLINOIS CARBON MONOXIDE ALARM DETECTOR LAW. Carbon Monoxide Law. Takes effect January 1, 2007 One outside each sleeping area

Protecting your home. For information on Gas Safe registered engineers in your area please visit or call

Professional Home Safety. X-Series CO Alarms. Battery Powered Carbon Monoxide Alarms XC70, XC100, XC100D

from the world leaders manufacturing over 35 million smoke, heat and carbon monoxide alarms every year

Technical Bulletin 005(B) Developed with Building Standards Scotland

WIRELESS GAS DETECTION & SHUT OFF SYSTEM INSTRUCTION MANUAL. Wireless Gas Detection & Shut Off System - User Manual & Instructions

Professional Home Safety. X-Series CO Alarms. Battery Powered Carbon Monoxide Alarms XC70, XC100, XC100D

Seriously how do you know your CO monitor is Working!

Link-Up. Solid Fuel Association Guide to Central Heating.

PLUMBING & CARBON MONOXIDE

Technical Bulletin. Concealed extended flues

5.5.1 General CD/30 (Oil Condensing Boiler Installation Assessment Form) General Technician Stationary...

CARBON MONOXIDE DETECTOR, i4h-co-m330

Protecting Children from Carbon Monoxide Poisoning

Addressable Carbon Monoxide Detection, Monitoring & Ventilation System

carbon monoxide Preventing carbon monoxide poisoning in your home

Part J of the Building Regulations: Changes for 2010 Tuesday 28 th September 2010 Presenter: David Bleicher

Carbon monoxide household alarm. DURAN ELECTRONICA. Tomás Bretón 50, Madrid, Spain

Office of the Fire Commissioner

HEAT YOUR HOME SAFELY

Model BR660VA Heat Engine

Carbon monoxide Knowing more

DOMESTIC SMOKE. working for a cleaner, quieter, healthier world

CHC's One Big Housing Conference Health and Safety Update: Gas Safety

Agenda. Intro Objective What is Carbon Monoxide Carbon Monoxide Law History Nelsons Law NFPA 720

Ontario is taking another step to keep families and homes in Ontario safe by making carbon monoxide alarms mandatory in all residential homes.

ULTIMATE INSET LIVE FUEL EFFECT GAS FIRE MODEL 417 OWNER GUIDE

169MHz Telecare Devices Gas & Carbon Monoxide Detector

Installation and User Guide

INSTALLATION AND OPERATION MANUAL

Combustion gases in your home: What you should know about combustion spillage

Esse B MODEL Roomheater with boiler WOOD BURNING ONLY MODEL

Rigoletto 60,90 & 120 Built-In Cupboard Hood

Annex 5a Solid fuel (Domestic) Annex 5a Common Minimum Technical Competency Requirements for Solid fuel burning appliance installation (domestic)

Building Regulations Update. by Eamonn Smyth

The Village of Franklin Gas Safety Pamphlet

Rigoletto 60,90 & 120 Built-In Cupboard Hood

Riva Studio Dedicated Sealed External Air Kit

Safety Alert New Gas Regulation 2013

Your guide to gas safety

Instruction Manual JLCHDD601/JLCHDD901 60cm/90cm Cooker hood

From Your Building Inspector

Carbon monoxide (CO) is a colorless, odorless gas that is the product of incomplete combustion of carbon-based fuels.

NCEHSA Conference. Carbon Monoxide Detector Regulations for Lodging Establishments (S.L )

OWNER GUIDE. Model 750. INSET LIVE FUEL EFFECT GAS FIRE Fitted with Harmony, Avignon or Style fascia. (GC No )

morsø PANTHER GAS STOVE

Safety in the home. 1

ARCHIVED. Compliance Document for New Zealand Building Code Clause G4 Ventilation Second Edition. Prepared by the Department of Building and Housing

TECHNICAL BOOK 4: OIL FIRED APPLIANCE & SYSTEM INSTALLATION REQUIREMENTS

Revolutionise your smart home at the touch of a button...

Model 341 Black Beauty Slimline

OWNER GUIDE. Anthem, Bolero, Camden, Minima, Victorian or Westminster fascia

MODEL 466 Radiant / Convector Gas Fire Black Beauty

Verdi 90 & 120 Ceiling Hood Re-Circulating and Ducted Installation & User Instructions

Ways we can help. Making your energy easy

INSET LIVE FUEL EFFECT GAS FIRE

COMBUSTION APPLIANCE SAFETY INSPECTION FOR VENTED APPLIANCES*

DIESEL/PARAFFIN HEATERS

Sonnet Plus Anthem Genesis Soraya

Introduction. Products conforming with a European Council Directive. CE marked construction products. Other regulations

Europe s Leading Manufacturer of Fire + Carbon Monoxide Alarms

OFTEC s role in promoting safe domestic oil storage

PARAFFIN/DIESEL HEATER

GrateGlow THE ALL NEW CAPITAL COLLECTION. G20 at 20mbar convertible to G31 at 37mbar. For use in GB and le. Users Instructions

A message from the Holyrood Fire Department. Chimney Fire Safety

Model 347 BLACK BEAUTY

Sonnet Plus Anthem Genesis Soraya

OWNER S GUIDE MODEL BR417 VA

ORT6WXA ORT9WXA Slide-out Rangehoods

Permanent Ventilators (for the Supply of Combustion Air)

Frequently Asked Smoke Alarm Questions

DIGITAL 7 YEAR LIFE CARBON MONOXIDE ALARM

Riva Studio Duplex. Inset Convector Cassette. Instructions for Use, Installation & Servicing

State of ALASKA, Weatherization Assistance Program. Technical Support Document. Combustion Safety

Gas appliances. Keeping them safe

Model Carbon Monoxide (CO) Alarm Response Policy

Leonardo 90 Wall Hood

Carbon Monoxide Detection in Buildings Frequently Asked Questions

Introduction Carbon monoxide (CO) is a colorless, odorless and tasteless gas which is toxic and can quickly become a mortal danger. Amongst others, ca

Decorative Fuel Effect Appliances

Baxi Brazilia F 5, F 5S, F 8S & Comfort Stat F 8ST Oak

Hamlet 60 & 80 Wall Hood

Transcription:

Safety Alarms Product Catalogue 2018

Protect Safety Alarms Deta s new range of interlinkable mains powered Smoke and Heat Alarms satisfy all Grade D domestic requirements as laid down by BS 5839: Part 6 and the Building Regulations of England & Wales, Scotland and Northern Ireland. (For more information contact Deta s Technical Services Department). Optical Smoke Alarms incorporates the latest optical sensing technology, which is more sensitive at detecting large particles of smoke, which tend to be produced in greater amounts by slow mouldering fires. Heat Alarms form an integral part of any domestic fire protection installation, with all Building Regulations recommending Heat Detectors within areas where dust and fumes may trigger nuisance alarms. Deta Carbon Monoxide Alarms are available for detecting dangerous levels of carbon monoxide gas. Carbon Monoxide alarms are available as interlinkable mains voltage or standalone battery models. Deta s award winning Carbon Dioxide Monitor meets the requirements for CO2 monitoring within the latest edition of the Scottish Technical Handbook for Domestic Dwellings (October 2015) 98

Safety Alarms Product Features Mains powered smoke and heat alarms incorporate a 9V battery backup and are interlinkable (up to 12 units) to provide maximum protection throughout the home. Easy Fix Simply rotate and connect alarm head to base Optical Smoke Alarm Fly Lead Simplifies connection for second fix installation 230V mains rated Battery back-up and low battery warning Interlinkable - up to 12 units LED operating indicators Removable dust cover Missing battery indicator Test button Dust Cap Prevents dust ingress during building works Silencer Sound output 85dB at 3m Maximum power consumption 9W Conforms to BS EN 14604:2005/AC: 2008 5-year guarantee EASY INSTALL 1163** Optical Smoke Alarm NEW 1163 Heat Alarm 230V mains rated Battery back-up and low battery warning Interlinkable - up to 12 units LED operating indicators Removable dust cover Missing battery indicator Test button Silencer Sound output 85dB at 3m Maximum power consumption 9W Conforms to BS 5446-2:2003 5-year guarantee EASY INSTALL 1165** Heat Alarm NEW **Available Summer 2018 1165 99

Safety Alarms Carbon Monoxide Alarms Carbon Monoxide is a poisonous gas created when fossil fuels go through a combustion process. It is tasteless and odourless and if you are exposed to it in unvented areas, it can have very serious health effects. There are various appliances around the home that can create carbon monoxide. These fossil burning appliances can include boilers, gas fires or portable heaters, your fireplace and even gas cookers. These appliances should be vented correctly to allow any carbon monoxide to be exhausted into the open atmosphere, taking it safely away. Carbon monoxide is created when the combustion of these fossil fuels is incomplete. To ensure that appliances are working correctly, they should be maintained regularly, preferably annually. The level of carbon monoxide is measured in parts per million (ppm). The maximum allowable concentration for continuous exposure is 35ppm in an 8 hour period. Know the danger signs Staining, sooting or discolouration around the appliance A yellow or orange flame where normally blue Condensation on walls and windows once the appliance is lit Rusting or water streaking on appliance cabinet/vent/chimney Loose or disconnected vent/chimney connections or guards What the regulations say The Building Regulations Approved Document J, 2010 edition, calls for carbon monoxide alarms to be provided in the room where a solid fuel appliance is installed, whether it is a new or replacement appliance being installed (clause 2.34). Where properties have flues that are concealed and in voids, inspection hatches need to be fitted, but until this happens CO alarms should be installed in the interim (TB008 Edition 2). Positioning of Alarms Alarms should be placed in the same room as the fuel burning appliance, between 1-3m away horizontally. The alarm should also be placed in any room that has a flue running through it. Alarms should not be positioned in enclosed spaces, for example behind curtains or cupboards, and not next to doorways or windows. 100

Safety Alarms Carbon Monoxide Alarms Test/silence button Mains powered and battery operated versions LED operating indicators In compliance with BE EN 50291:2001 Mains powered: 5-year guarantee Battery powered: Long life 7-year sensor and sealed for life battery Battery powered: 7-year guarantee 1121 Carbon monoxide alarm - mains powered 1137 Carbon monoxide alarm - battery powered 1121 1137 Carbon Dioxide Monitor Mains powered Monitors average CO2 levels for previous 8 hour and 24 hour periods Monitors highest CO2 level for previous 24 hour period Display uses traffic light system indicating CO2 levels and if improved ventilation is required Surface mountable, or will mount on a standard 1 gang flush mounting back box 2-year guarantee 1141 Carbon Dioxide Monitor WINNER of BEST NEW PRODUCT 2016 at the Electrical Industry and Select Awards. ELECTRICAL INDUSTRY AWARDS 2016 Winner 1141 101

Deta Electrical Company Limited Kingsway House Laporte Way Luton Bedfordshire LU4 8RJ UK t: +44 (0) 1582 544 544 f: +44 (0) 1582 544 501 e: sales@detaelectrical.co.uk w: detaelectrical.co.uk