A.U.P.C.I ASOCIACIÓN URUGUAYA DE PROTECCION CONTRA INCENDIO AUPCI

Similar documents
Foam Products ENGLISH

SECURITY BLANKET Foam Fire Protection Products

TECHNICAL DATA 3% AR-AFFF

The metering orifice is sized according to the type and percentage of concentrate used and is also secured with a stainless steel retaining ring)

WILLIAM HICKS. MSc, CFEI, CFPS, IAAI-CFI, MIFireE, EFO, CFOD, F-IAFI. Associate Professor Eastern Kentucky University

Foam Systems U.S. Quick Reference Guide

Technical Article. Foam Systems - Low Expansion, Medium Expansion, High Expansion. Martin Workman, Product Manager Special Hazards Division

II Brazilian Sprinkler Conference October 27-28, 2016

Tel Web: dyayan.com

A HISTORICAL REVIEW OF FLUORINATED FOAM FIREFIGHTING AGENTS, PERFORMANCE REQUIREMENTS/ ENVIRONMENTAL SAFEGUARDS REVIEW

HKIE CPD Training Course (II) 23, 25 June and 7, 9 July 2009

TYPES OF EXTINGUISHING AGENTS

Aircraft Hangers. ft. (3,716 sq. m) per hangar construction type as defined by NFPA 409

Aircraft Hangars DESCRIPTION. A single fire area not larger than 40,000 sq. ft. (3,716 sq. m) per hangar construction type as defined by NFPA 409

Second Revision No. 11-NFPA [ Section No. 2.4 ] Submitter Information Verification. Committee Statement

PERFORMANCE AT HAND RED LINE Hand Portable Fire Extinguishers

Transforming Challenges with Expertise. Total Protection. from concept to commissioning

The Next Generation of Foam Fire Suppression. Automatic CAF Fire hose reel system FEATURES

TWO TIMES THE FIGHT Twin-Agent Fire Suppression Systems

& Fire Extinguisher Training

Foam Products. Quick Reference Guide EMEA. Trusted above all.

Self Expanding Foam Fire Suppression System SPECIFICATION SHEET Rev

JET-X HIGH-EXPANSION FOAM GENERATORS Data/Specifications

Exploration and extraction can be on land or on offshore platforms. Once extracted, ground transportation is done by means of oil or gas pipelines,

ANSUL. Twin-Agent Fire Fighting/Securing Systems Specifications. Models 450/50-B, 450/100-B, 900/100-B INDEX SPECIFICATIONS

Creating A Global Industrial Leader

An Overview Of Fluorinated Firefighting Foams: Past, Present & Future Presented by: Jerry Back, JENSEN HUGHES FOAM SYSTEM SYMPOSIUM

Twin-Agent Fire Fighting/Securing Systems Specifications

TECHNICAL DATA OBSOLETE

The Combustion Process THE FIRE TETRAHEDRON FUEL TEMPERATURE

MODULE 2. Water-Based Suppression System Basics

Fire Suppression Solutions

standard in firefighting foam technology worldwide

Technical Article. High Expansion Foam Systems. Martin Workman Viking Product Manager. September,

CITY OF MOBILE. Purchasing Department and Package Delivery: Government Plaza 4th Floor, Room S Government St Mobile, Alabama 36644

The development Of the new CEN standard For fire fighting foam systems EN13565 Part 2

BP U.S. Pipelines and Logistics (USPL) Safety Manual Page 1 of 6

OPTIONAL INFORMATION PORTABLE FIRE EXTINGUISHERS SELF INSPECTION CHECKLIST

To understand FIRE and how to EXTINGUISH it, we first need to know: What is FIRE?

POLY extinguishing systems. The high-performance, unique, and versatile extinguishing system for initial, effective fire fighting.

Hazard Control Technologies, Inc.

INSTRUCTOR GUIDE COURSE: FIREFIGHTER PRE-BASIC SESSION REFERENCE: 1 TOPIC: ORIENTATION AND FIRE BEHAVIOR LEVEL OF INSTRUCTION:

Portable Fire Extinguishers

FireIce & FireIce Shield F.A.Q.

Fire Fighting Foam and Foam Hardware

FIRE AND FIRE FITTING By Mr. Prashant Sansare

Foam Solutions, LLC Performance Parkway, Columbus, Ohio Ph ; Fax

STORED PRESSURE YES TEST STANDARDS: CAN/ULC S504 & ANSI/UL 229 CAN/ULC S508 & ANSI/UL 711. Available Options: Stationary Design Tow Loop

Firefighting. It is the temperature at which a substance will continue to burn, when ignited.

A.8.6 Part 6 : Special Fire Extinguishing Systems

Three elements of fire. Heat Oxygen Fuel. Remove one of the three and the fire is extinguished.

Firefighting Foam Concentrates Protecting what matters. Protecting lives, the environment and critical assets

GUILFORD COUNTY SCHOOLS

Fire Extinguisher Training

extinguishers. extinguishers. Skills Objectives

GEPRO PROTECTIA LA INCENDIU

MSC Guidelines for Foam Fire Suppression Systems

HIGH-EXPANSION FOAM GENERATORS

Savard Labor & Marine Staffing, Inc. Fire Prevention Program Rev3/14

Chapter 3 FF II Fire Department Communications

A Guide for Meeting NFPA 10 Subsection

Fire Risks in our Woodshops. Sam Altshuler January 2018

FireAde 2000 Hydrocarbon suspension technology

FoamFatale INTRODUCTION OF A NOVEL HIGH END TECHNOLOGY FOR LARGE ATMOSPHERIC STORAGE TANK FIRES. TFEX 1 Ltd.

CrownFire Foam Systems

Safety is more than just being careful: it

Risk Management Department. Fire Extinguishers

Model Policy On Portable Fire Extinguishers (Ontario Version)

Fire Extinguisher Training

7 Fire Protection Systems Synopsis

2007 Fire Equipment Product Catalog

LOW EXPANSION FOAM FIRE EXTINGUISHING SYSTEM

RIM SEAL SYSTEMS E-BOOK

MAXIMUM KNOCKDOWN ABILITY Large Dry Chemical Fire Suppression Systems

Fixed firefighting systems Foam systems

READY FOR CHANGE. A Guide for Meeting the NFPA Compliance Standard for Portable Fire Extinguishers

The regulatory section first discusses codes and standards and then Federal and State legislative and local requirements.

ONE SEVEN FAST. EFFECTIVE. SAFE. ENVIRONMENTALLY FRIENDLY

XL PLUS FFC (EQUALLY USABLE AT: 1%, 3%, & 6%) PFE-FR FFC EXP FFC

Portable Fire Extinguishers

Extinguishers. Commercial Industrial High rise buildings

SERT FIRE ELEMENTS & HAZ MAT

FOAM CHAMBER MODEL - FCA & FCA-S HD FIRE PROTECT PVT. LTD. TECHNICAL DATA FEATURES APPLICATION

SPECIAL HAZARDS THE MOST ADVANCED TECHNOLOGY FOR PROTECTING

PRODUCT OVERVIEW P.O. BOX 1359 MAURICEVILLE, TX HR EMERGENCY

FOAM CHAMBER MODEL - FCA & FCA-S TECHNICAL DATA FEATURES APPLICATION. Carbon Steel Construction FCA-65, FCA-80 & FCA-100. Stainless Steel Construction

FUEL. Fire & Flammable Liquids Properties. Flammable & Combustible Liquid Safety. Safety. Practice. Laws: OSHA & NFPA. Safety.

Fire, extreme heat, smoke, toxic fumes, noise, falling objects, uneven terrain, debris,

Hazardous Goods Warehouse. VOSSCHEMIE GmbH. Preventive Fire Protection. Case study

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

Deluge & Preac tion Systems

IMO. Resolution A.951(23) Adopted on 5 December 2003 (Agenda item 17) IMPROVED GUIDELINES FOR MARINE PORTABLE FIRE EXTINGUISHERS

Public Input No. 2-NFPA [Chapter F]

Global innovation in fire fighting

EXTINGUISHMENT AND BURNBACK TESTING OF FIRE FIGHTING AGENTS

Leader s Guide 2007 CLMI Training

Portable Fire Extinguishers

COGEN CONSULT. Page 1 of 23

Institute for Plasma Research Welcomes you all on

You will be able to carry out the following activities: use firefighting tools in an appropriate and competent manner

Transcription:

A.U.P.C.I ASOCIACIÓN URUGUAYA DE PROTECCION CONTRA INCENDIO

Foam Overview

Applications Flammable Liquid Storage Tanks Diked Storage Tanks Loading Racks/Transfer Stations Closed Head Sprinkler Systems Deluge Sprinkler Systems

Applications Aircraft Hangers Flammable Liquid Storage, LNG Coal Transfer Houses, Mines, Basements Hush Houses, Turbine Generators, Solvent Rooms

Introduction to Foam & Fuels A B C D Ordinary Combustibles Wood Cloth Paper Wool Flammable Liquids Gasoline Acetone Kerosene Energized Electrical Equipment Transformers Computers Electric Ovens Combustible Metals Magnesium Titanium Zirconium Sodium Potassium CLASS A FOAM CLASS B FOAM FOAM NOT RECOMMENDED

Why use Foam? Many agents can extinguish a Class B fire, however foam provides: Firefighter Safety! Prevention of Fuel Ignition, or Re-Ignition Suppression of Flammable Vapours Post Fire Security Economical

Agents & Hardware

Expansion Ratio NFPA 11 Foam Extinguishing Systems xxxx Low Expansion - < 20:1 Medium Expansion - 20:1-200:1 High Expansion - > 200:1

Protein & Fluoroprotein Concentrates 20-120 O F ((-7)-49 O C)

Protein-Based Foam Concentrate Minimum Shelf Life Protein & Fluoroprotein 7 to 10 Years

Synthetic AFFF s

Aqueous Film Forming Foam (AFFF) Concentrates (-20)-120 O F ((-29 )-49 O C) Mil-Spec 35-120 O F (2-49 O C)

AFFF Solutions

Class B Foam Agents For Polar Solvent Fires... 0-120 O F ((-17)-49 O C) 35-120 O F (2-49 O C)

Polar Solvent Solution Adds a POLYMERIC MEMBRANE. A thin, durable, plastic like layer formed on a polar solvent fuel surface protecting the foam cells from destruction by the fuel

Medium Expansion Foam Long Drain Time Vapor Suppressors Designed for Hazardous Chemicals NOT FIRE FIGHTING Refer to Data Sheet and CLO2 Case Study

High & Medium Expansion Foam Agents 35-120 O F (2-49 O C)

High Expansion Foam ADVANTAGES OF HIGH-EXPANSION FOAM Low water consumption - minimal water damage. Controls three-dimensional fires. Excellent foam mobility & stability. Reduces the need for containment and/or fire pumps. Low foam consumption. Cost effective and expedient installation. Minimized maintenance. Environmentally-friendly.

Class A Foam Concentrate U.S. Forest Service Approved for Toxicology & Corrosion Standards for Fixed Wing Aircraft, Helicopter Bucket & Ground Application. Biodegradable 2009 30-120 O F ((-1)-49 O C)

Class A Foam Uses FORESTRY MARKET Ground Attack Used to form a firebreak Helps Prevent Rekindling Applied from plane in hardto-reach areas

Class A Foam Concentrate Can be used with any type of water or foam nozzle. Performs with fresh, brackish or sea water. Proportioned from 0.1% to 1.0% Can be used on Class B Hydrocarbon Fires if higher expansion ratios are used.

Municipal Class A Foam

Class A Foam Concentrate Reduces surface tension of water. Reflects heat (white bubbles) Insulator between fuel and oxygen. Clings to surface acting as a slow drain foam.

Synthetic Foams Minimum Shelf Life AFFF, Class A, Polar Solvent & Multiple-Expansion Concentrates 20 to 25 Years Premixes 3 to 5 Years Refer Tech Bulletin 54 ¼ Mineral Oil when Stored in Atmospheric Tanks

Shipping Containers Sizes include 5 gal. (19 lit.) pails 55 gal. (208 lit.) drums 265 gal. (1000 lit.) totes

Foam Testing NFPA recommends yearly inspection and testing of foam concentrate. Ansul test labs perform a complete analysis including panfire & quality testing. Foam Concentrate Test Kit is available for submitting samples to Ansul. Refer to Foam Test Kit Data Sheet.

Line Proportioners Eductors CONCENTRATE Venturi Device

Line Proportioners Typical Water Pressure required at inlet 125-200 PSI. Maximum Back pressure beyond Outlet can not exceed 65% of Inlet Pressure. Fixed Flow Venturi Device

Complimentary Packages

Portable High Expansion Foam Generators with Built-in Eductor

Master Foam Tote Trailer 350/500/750 GPM (1325/1893/2839 LPM)

Balanced Pressure Proportioning Bladder Tanks Pump Skids In-line / Pump Modified Venturi Device

Balanced Pressure Proportioners

Bladder Tanks

FLOWMAX CL Variable Range Proportioner Designed To Meet The Requirements Of NFPA 16 & 30 Standards Fast Response (Foam Proportioned With 1-2 Sprinkler Heads Open) Expanded Flow Range Of 25-3,000 gpm Min/Max Flow Rate Ratio 1:120 Standard Proportioner Ranges: 3 = 70-800 gpm 4 = 200-1,600 gpm 6 = 300-3,400 gpm 8 = 500-5,500 gpm

Pump Skid / Diaphragm Valve

In-Line Balanced Pressure Pump Proportioning System

In-Line Balanced Pressure Pump Proportioner

Discharge Devices

Sprinklers Air-Aspirated (B-1) Conventional Non-Aspirated

Monitors Tank Farm Applications

Monitors For Many ANSUL Monitors Nozzles are Options Design Factors Waterway Friction Loss Required K-Factor

Monitors FJM Monitors High-Flow Series Built-in Nozzles Field Adjustable K-factors Options Oscillating Educting Remote Control

Foam Chamber

Foam Chamber Type II

Floating Roof Foam Maker

Floating Roof Foam Maker

Floating Roof Foam Maker

Floating Roof Foam Maker

Floating Roof Foam Maker Foam Pourer

Fixed High Expansion Foam Generators

Generator Components

Large Volumes of High Expansion Foam can be produced.

LNG Local Application 500:1 & 6 cfm/ft2

ANSUL ADVANTAGES Both Dry Chemical and Foam Systems Name Brand Recognition R&D Testing Facilities Global Support of Sales

Questions? Thank You

Thank You