Fuji Electronic VFC 084P-5T

Similar documents
The G.P.I. Max-Air is a non-positive displacement, high volume, low pressure vacuum motor that can operate as a vacuum, compressor or blower.

TURBO AND HIGH PRESSURE REGENERATIVE BLOWERS

FEATURES. Vacuum Motor. Moving Ahead With Technology

MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS

SECTION PLUMBING EQUIPMENT Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections.

INDUSTRIAL. Vacuum Products

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

Blowers - HIGH PRESSURE BLOWER - HIGH VACUUM BLOWER

Selecting the Correct Fan

CLOSED COUPLED CENTRIFUGAL PUMPS

Blowers Vacuum Pumps Compressors INNOVATION DESIGN SOLUTIONS

Multistage Centrifugal Blowers

Multistage Centrifugal Blowers

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

FLANGE-MOUNT CENTRIFUGAL PUMPS

Introduction to Fans. The Basics of Fan Principles and Terminology

Blowers. Side channel compressors and vacuum pumps. Your Choice, Our Commitment

End-Suction Centrifugal Pump

End-Suction Centrifugal Pump

V-Series Oil Lubricated Rotary Vane

Design and Construction Standards SECTION PLUMBING EQUIPMENT

AIR PROCESS COMPRESSORS PUMPS BLOWERS. vacuum pressure

SECTION FIRE PUMP AND CONTROLS

SECTION STEAM CONDENSATE PUMPS

DLKF. EBARA Submersible Sewage Pumps Specifications Project: Model: Chk d: Date:

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

HOFFMAN & LAMSON ENGINEERED VACUUM SYSTEMS

Multistage Centrifugal Blowers

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPO. Open Impeller ASME (ANSI) B73.1 Pump for continuous use in Chemical Process Services

Rotodynamic Pumps INTRODUCTION:

The PV100x fans feature Class F motor insulation. 5 year fan housing and motor warranty

Vacuum Systems. A complete line of vacuum pumps and accessories for every dairy

Series SR Compact Centrifugal Mag-Drive Pumps. WARRENDER, LTD. Process & OEM Pumps From Stock or Built-to-Spec

CPO N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. ASME/ANSI B73.1 Chemical Process Pump. Springer Pumps, LLC

5 year fan housing and motor warranty

INSTALLATION MANUAL FOR ROTARY TWIN LOBE (ROOTS) BLOWERS / COMPRESSORS

GH Series End Suction Centrifugal Pumps For Flows to 2,500 GPM

A. Codes and Standards that are Standard at the University:

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls

The Experts in Vacuum Solutions

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

5. CONDENSATE PUMPS/UNITS

Vent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls Rev. 06/27/14

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

SECTION PLUMBING EQUIPMENT

RELIABLE SOLUTIONS FOR INDUSTRIAL APPLICATIONS ENGINEERED VACUUM SYSTEMS

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPO. ASME/ANSI B73.1 Chemical Process Pump

V-Series. Oil Lubricated Rotary Vane Vacuum Pumps

Domestic Pump Series VCMD TM Combination Vacuum & Boiler Feed Unit

RGE 13 A T - 1 A

KIC Air Curtains. Technical Guide

Pumps SELECTION OF A PUMP

1.1 This section applies to air handling units for HVAC Systems.

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y VTP. Vertical Turbine Pump

Full-line Product Overview

3020/3120 Series DEMING PUMPS. Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet

G-Series Side Channel

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

G-Series Side Channel

MARLOW PUMPS RECIRCULATION

ENGINEERING LETTER 4

FX5 Series Explosion-Proof Electric Air Heaters

Roots TM Blowers, Compressors & Controls

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

Booster Compressors N Series. Pressures to 650 psig Capacities 9.5 to 724 cfm

Scirocco (tri-lobe) blowers Tri-lobe design for higher efficiency and reduced noise levels in the Water Industry

Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS

DUPLEX CONDENSATE TANK SYSTEM

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

SECTION PLUMBING EQUIPMENT

Horizontal Split Case Pumps Type U

AIR COOLED PACKAGED CHILLER

SECTION XXXXX POSITIVE DISPLACEMENT BLOWER WITH SOUNDSEAL COMPACT ENCLOSURE

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

Standard Features. Performance/Capacities

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

Technologies for all vacuum F-Series Radial and pressure applications

Guidelines for Optimizing Drying and Blow-Off Operations

Fans: Features and Analysis

Rich Knoelke. Questions or Comments: Mulcahy Shaw Water.

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING

SULLAIR DESICCANT DRYERS

A. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals.

KEENER GRINDER PUMPS

Thermal Management INDEX. Management. Thermal TM-1

Air Conditioning Components

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Global Series Screw Air Compressors Life source of industries

DualPak Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Sept. 28, DualPak 6900 Series Booster System

fans & heaters SIMPLE, ROBUST AND RELIABLE

Multistage Centrifugal Blowers/ Exhausters CAST SERIES

DAE Systems. Fan Selection Guide. Section 1: Terminology

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

TM Series. Induced Draft, Counter Flow Optional Accessories

Transcription:

Fuji Electronic VFC 084P-5T Fuji s complete line of ring compressors is designed to meet the most critical application requirements. Each features an impeller, mounting base and housing manufactured of aluminum alloy for maximum strength, reduced weight and increased corrosion resistance. The compressor and motor are constructed as a unit for mechanical simplicity and maximum structural integrity. The elimination of clutches, gears, belts, and sliding vanes reduces periodic maintenance while increasing reliability. Reduces noise levels to below OSHA standards. Promotes smoother air flow and higher volumetric efficiency. Smoother operation. Allows vibration-free installation in OEM equipment. Better grease retention. Increased reliability. Protects bearings from contaminants for longer life. Eliminates the need for couplings, belts, or gears. Nothing to break or wear out. Minimizes OEM inventory requirements. Cools the motor and blower. Quieter running and more efficient. Protects the motor from overheating for greater reliability by cooling the motor and blower. Easy replacement in OEM equipment.. Features: Suction and discharge silencers Die cast impeller Dynamically balanced impeller Double shielded shaft bearing Dust-proof shaft seal Motor shaft-mounted impeller 50/60 Hz motors, wide voltage range Improved cooling fan design Built-in thermal protector Compact design Removable threaded flanges Contact us for a price on this Refurbished Enclosed Fuji Electronic Blower! 363 W. SOUTH AIRPORT ROAD - TRAVERSE CITY, MI 49686 - BUS: (231) 264-3000 - FAX: (231) 264-3001 6140 RASHELLE DRIVE, SUITE 1 - FLINT, MI 48507 - BUS: (810) 238-9190 - FAX: (810) 238-9195 7082 GRANGE HALL ROAD - HOLLY, MI 48442 - BUS: (800) 423-43 www.global-treatmentsolutions.com

FECOA-2 FUJI ELECTRIC CORP. OF AMERICA Park 80 West Plaza II Saddle Brook, NJ 07663 Phone (1) 712-0555 Fax (1) 368-8258 5/00-5M

PROFILE Fuji Electric, established in 1923, is a world leader in the electric and electronics industries. Originally a heavy electrical equipment manufacturer, Fuji Electric has grown to include power and energy systems, industrial and electrical controls, electronics, information processing, semiconductors, process and factory automation equipment, robot control systems, fuel cells and vending machines. In 1963, Fuji Electric introduced a line of Ring-Compressors in Japan, followed in 1970 by their introduction in the United States. This product was intended to meet the increasing needs of sophisticated equipment for substantial volumes of oil-free compressed air and vacuum at low to moderate pressures. Since that time, these units have gained an unexcelled reputation for performance, reliability and quality in thousands of applications, and in all types of environments. They have been constantly improved to meet even more demanding performance and environmental specifications. This catalog introduces the latest series of Ring-Compressors manufactured by Fuji. While general performance specifications remain unchanged, these new series meet the need of increasingly stringent noise requirements, with quieter operating units. Fuji Electric maintains worldwide sales and service facilities to provide the fastest possible response to calls for applications assistance as well as customer service. If any further information regarding any of the material in this catalog is necessary, our sales representatives will be only too happy to provide assistance. FUJI ELECTRIC CORP. OF AMERICA PARK 80 WEST PLAZA II SADDLE BROOK, NEW JERSEY 07663 PHONE (1) 712-0555 FAX (1) 368-8258 1 Fuji Electric

PRINCIPLES OF OPERATION AND CONSTRUCTION PRINCIPLES OF OPERATION The Fuji Ring Compressor is a non-positive displacement, high volume, low pressure blower that can operate as either a compressor or a vacuum pump. It is also known by other names such as: regenerative blower, vortex blower, and side-channel blower. All of the names describe the basic principle of operation of the blower. The blower consists of an impeller mounted directly on a motor shaft and is rotated at a high speed, about 3600 RPM. On the periphery of the impeller is a large number of radial blades. The impeller is positioned between two end-plates with the blades located with a channel on either side (hence, the name side-channel ). As the impeller spins and the blades pass the inlet port, a low pressure area is created that draws in air, or other gases. The impeller blades impart motion to the air by centrifugal force, throwing it outward and forward, where it follows the contour of the side-channel and is returned to the base, or root, of the impeller. This action is repeated many times, creating a vortex. Each regeneration causes the air to gain pressure until it reaches the portion of the housing where the air is stripped from the impeller and discharged from the blower. The ring compressor is, in effect, a multi-stage compressor with each regeneration of the air becoming another stage. The pressure increase at each stage in the cycle is very small, but the large number of stages yields inlet vacuum levels of up to 8 in. Hg and discharge pressures of up to 5 PSIG, depending on the size of the blower. Flow levels of up to 570 SCFM can be achieved, and discharge air is free of annoying pulsations. The basic construction of a ring compressor means that the only moving part is the impeller. Nothing touches except the bearings. The method of compression means that there is no requirement for lubrication in the compression chamber; the discharge air is oil-less. No oil aerosols are present in the discharge air; nor carbon dust generated by sliding vanes. The blowers may be mounted vertically (with impeller housing down) or horizontally. Vane Housing Impeller CONSTRUCTION Fuji s complete line of ring compressors is designed to meet the most critical application requirements. Each features an impeller, mounting base and housing manufactured of aluminum alloy for maximum strength, reduced weight and increased corrosion resistance. The compressor and motor are constructed as a unit for mechanical simplicity and maximum structural integrity. The elimination of clutches, gears, belts, and sliding vanes reduces periodic maintenance while increasing reliability. TEFC (totally enclosed, fan-cooled) motors are standard on all models, except VFC063P and VFC100 models, which are TENV (totally enclosed, non-ventilated). In addition, all models have NEMA class B, or class F (model VFC704), insulation, and are Underwriters Recognized (Yellow Card File E54355), CSA certified (File LR48762), and meets CE. All single phase units have built-in automatic reset thermal protectors, except models VFC400P and VFC504P. All three phase units have pilot duty thermal protectors requiring only the addition of an external contactor for overload protection, however, magnetic motor starters are recommended. All ring compressor impellers are dynamically balanced to virtually eliminate vibration while increasing overall long-term reliability. Most models have a shaft oil-seal between the impeller and bearing, as well as a double shielded bearing to reduce the possibility of foreign material influx and preclude air contamination. Fuji Electric 2

OVERVIEW FEATURES Suction and discharge silencers Die cast impeller Dynamically balanced impeller Double shielded shaft bearing Dust-proof shaft seal Motor shaft-mounted impeller 50/60 Hz motors, wide voltage range Improved cooling fan design Built-in thermal protector Compact design Removable threaded flanges BENEFITS Reduces noise levels to below OSHA standards. Makes it more comfortable for employees working near the blowers. Promotes smoother air flow and higher volumetric efficiency. Smoother operation. Allows vibration-free installation in OEM equipment. Better grease retention. Increased reliability. Protects bearings from contaminants for longer life. Eliminates the need for couplings, belts, or gears. Nothing to break or wear out. Minimizes OEM inventory requirements. Cools the motor and blower. Quieter running and more efficient. Protects the motor from overheating for greater reliability. Space saving design makes it easier for OEM s to incorporate the blower into their equipment. Easy replacement in OEM equipment. Housing 50/60 Hz Squirrel-Cage TEFC Motor Shaft Seal Built-in Thermal Protector Double Shielded Bearing Terminal Box Direct Motor-Impeller Drive Removable Threaded Flanges Dynamically Balanced Impeller Built-in Silencer 3 Fuji Electric

SELECTION GUIDE FUJI RING COMPRESSOR MODEL NUMBER DESIGNATION VFC 5 0 0 A -7W Fuji Prefix Numbers 0-9 = Blower Size Special Blower Reference Configuration Control Number P = Single Phase Blower A= Three Phase Blower Voltage Designation: 1T = 115V; 50/60 Hz; 1 Ph. 2T = 230V; 50/60 Hz; 1 Ph. 0-230V; 50/60 Hz; 3 Ph. 5T = 115V/230V;50/60 Hz;1Ph. 4W= 460V; 50/60 Hz; 3 Ph. 7W= 0-230/460V; 50/60 Hz; 3 Ph. 5W= 575V; 60 Hz; 3 Ph. (For specific electrical data see pages 50, 51) Fuji Electric 4

TABLE OF CONTENTS Company Profile...1 Principle of Operation...2 Construction...2 Features and Benefits...3 Selection Guide...4 Technical and Performance Data VFC063...6 VFC504P/500A...18 VFC084...8 VFC600... VFC100...10 VFC704...22 VFC0...12 VFC804...24 VFC300...14 VFC904...26 VFC400...16 Accessories Inlet Filter...28 Fiberglass Screen Collection Bags...31 Inlet Filter Covers...28 High Volume Filter / Receivers...32 Inlet Filter / Silencers...28 Canton Flannel Filter Bags...32 Inlet Filter / Silencer Replacement Elements...28 Disposable / Reusable Filter Bags...32 Inline Vacuum Filters...29 Vacuum and Pressure Relief Valves...33 Inline Vacuum Filter Replacement Elements...29 Vacuum Boosters...34 Inline Filter Traps...30 Aspirators...34 Exhaust Silencer (Mufflers)...30 Blower / Aspirator Performance Curves...35 Inlet Filter / Receivers...31 Air Knives...38 Applications General Classifications...36 Tank Agitation...42 Typical Applications...37 Tank Ventilation...43 Spas and Hot Tubs...40 Engineering Air Flow Through an Orifice...44 Altitude-vs-Barometric Pressure...47 Flow Coefficients for Orifices...45 Temperature Conversion Chart...48 Pressure Drop Through Tubing...46 Conversion Charts...49 Electrical...50 Design Considerations...52 Operating Limits...53 5 Fuji Electric

VFC084 ROTATION 1.93 7.76 7.21 4.33 7.80 4.02 SUCTION HOSE FLANGE PRESSURE HOSE FLANGE 4.17 1.26 DIA. 1.18 3.66 6.93 1.10 3-Phase version shown Contact factory for other versions.394 DIA. (2 HOLES) 2.95 6.50 7.41 The VFC084 is a single-stage ring compressor with a maximum pressure of 19.5 in. H 2 O, and a maximum vacuum of 18.7 in. H 2 O, and a maximum capacity of 19.5 SCFM. It comes complete with a direct-drive, 1/10 horsepower, TEFC motor capable of operating on a wide range of voltages and on 50 or 60 Hz. A pilot-duty thermal protector is standard equipment on all 3-phase models, and built-in automatic reset thermal protectors on 1-phase units. All versions have NEMA class B insulation, are UL recognized, CSA certified and CE. SPECIFICATIONS 1 Phase Model No. Hz Low Voltage/High Voltage in. H 2 O in. H 2 O SCFM SCFM F( C) lbs.(kg) VFC084P-5T Voltage Amps (Max. Rated) Amps (Locked Rotor) Max. Pressure Max. Vacuum Max. Airflow Min. Airflow 60 115/230 1.2/0.6 3.4/1.7 19.5 18.7 19.5 0 54(30) 50 110/2 1.1/0.5 3.2/1.6 15 14.4 16.5 0 36() Max. Temp Rise ( T) Weight 3 Phase VFC084A-2T 60 0-240 0.42-0.40 1.8-2.1 19.5 18.7 19.5 0 54(30) 13.3 (6.0) 50 190-230 0.37-0.32 1.8-2.1 15 14.4 16.5 0 36() VFC084A-4W 60 400-480 0.21-0. 0.9-1.1 19.5 18.7 19.5 0 54(30) 50 380-460 0.18-0.16 0.9-1.1 15 14.4 16.5 0 36() ACCESSORIES Vacuum Pressure Inlet Inlet Filter Inlet Exhaust Description Relief Valve Relief Valve Filter Cover Filter/Receiver Silencer/Muffler Model No. Not Req d Not Req d F-123 C-123 R15P1.5 VFY-021A See Page No. 28 28 31 30 NOTE: Maximum allowable time at deadhead is unlimited Fuji Electric 8

PERFORMANCE DATA PRESSURE VACUUM 0.4 0.3 0.2 0.1 AMPS (230 V/3 PH) 0.4 0.3 0.2 0.1 140 100 60 WATTS 140 100 60 18 16 14 12 10 8 6 4 2 0 0 2 4 6 8 10 12 14 16 18 Flow (SCFM) STATIC PRESSURE (Inches of Water) 18 16 14 12 10 8 6 4 2 0 0 2 4 6 8 10 12 14 16 18 Flow (SCFM) 60 Hz 50 Hz TEMPERATURE RISE SOUND LEVEL Degrees F Degrees C Sound Pressure Level (dba) 48 28 60 44 40 36 26 24 22 55 32 28 18 16 50 24 16 12 8 4 14 12 10 8 6 4 2 45 40 35 0 0 0 2 4 6 8 10 12 14 16 18 Flow (SCFM) 30 100 1000 10000 Frequency (Hz) *Measured at distance of 1.0 meters 9 Fuji Electric