Submittal. Split System Cooling 4A7A6024J-SUB-1B-EN. January A7A6024J1000B TAG:

Similar documents
Submittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG:

Product Data. Split System Cooling H-EN. January 2017

Product Data. Split System Cooling D-EN. August 2016

Service Facts. Split System Cooling 3.0 Ton 4A7A6036J-SF-1B-EN. January A7A6036J1000A

Product Data. Split System Heat Pump D-EN. February 2016

Product Data. Split System Cooling E-EN. November 2016

Product Data. Split System Heat Pump A-EN. March 2016

Product Data. Split System Heat Pump B-EN. February A6H6024H1000A

Product Data. Split System Heat Pump

Product Data. Side Discharge AC Models 4TTL6018A1000A 4TTL6024A1000A 4TTL6030A1000A 4TTL6036A1000A 4TTL6042A1000A 4TTL6048A1000A 4TTL6060A1000A

Product Data. Split System Heat Pump 4TWR4018G1000A 4TWR4024G1000A 4TWR4030G1000A 4TWR4036G1000A 4TWR4042G1000A 4TWR4048G1000A 4TWR4060G1000A

4TTB3060D1000B 208/230/1/60 35 SCROLL /230/1/ /8

Split System Cooling Product & Performance Data

7/8 NO NO NO PROPELLER DIRECT / /230/1/ SPINE FIN /8 8 LBS., 0 OZ. YES 7/8 3/8

208/230/1/ CLIMATUFF /230/1/ YES NO NO PROPELLER 23-1 DIRECT / /230/1/ SPINE FIN

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6024-SF-1B. Split System Cooling 4TTR6024A1000B CAUTION CAUTION WARNING

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTB6-SF-3. Split System Cooling 4TTB6048A1000A, 4TTB6049A1000A CAUTION

4TTR6036B1000A 208/230/1/ CLIMATUFF - SCROLL 3/4 3/4 3/4 3/4 3/4 208/230/1/ NO YES NO PROPELLER DIRECT

4TTB3030D1000B 208/230/1/60 4TTB3036D1000B 208/230/1/ RECIP /230/1/ RECIP YES YES

Product Data. Split System Cooling A. November 2013

4A6H5042G1000A 208/230/1/ DURATION - SCROLL 3/4 208/230/1/ NO (Use BAYKSKT263) YES YES PROPELLER DIRECT

4A6H5049E1000B 208/230/1/ /8 7/8 7/8 7/8 DURATION 208/230/1/ /230/1/ SPINE FIN 13 LBS., 10 OZ. YES

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6048-SF-1A. Split System Cooling 4TTR6048A1000A CAUTION CAUTION WARNING

Product Data Split System Cooling

208/230/1/60 5/8 5/8 5/8 5/8 5/8 20 CLIMATUFF /230/1/

Service Facts. Split System Heat Pump 4A6H5019H-SF-1C-EN. August A6H5019H1000A

SPLIT SYSTEM COOLING 1 1 / 2 5 TON MODELS 4A7A

3-11/ /8 4-5/16 6-5/8 5-7/8 1-9/16. Condensate drain connection 3/4 NPTI (Trap required) Electrical service access compartment panel

Submittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG:

Submittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG:

Split System Cooling Product Data

Split System Cooling Product Data

Split System Heat Pump Product Data

Split System Cooling Product Data

Split System Heat Pump Product Data

Split System Cooling Product Data

Split System Cooling Product Data

Split System Cooling Product Data

Submittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG:

AMERICAN STANDARD 14 MODELS 4A7B E

Split System Heat Pump Product Data

Split System Heat Pump Product Data

Split System Heat Pump Product & Performance Data

Split System Heat Pump Product Data

Variable Speed Convertible Air Handler 5 Ton

SPLIT SYSTEM HEAT PUMP 2, 3, 4 & 5 ton HERITAGE 20 MODELS 4A6Z0024, 036, 048, & 060A. with AccuLink and Charge Assist

Variable Speed Convertible Air Handler 4 Ton

SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON MODEL 4A7A American Standard Heating & Air Conditioning

Split System Cooling Product & Performance Data

Variable Speed Convertible Air Handler 2 1/2 Ton

Product Data. Convertible Air Handlers 1 1/2 5Ton

Split System Cooling Product Data

Split System Cooling Product Data

Split System Cooling Product Data

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

Product Data. Convertible Air Handlers 1 1/2 5Ton

Split System Heat Pump Product Data

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning

Split System Cooling Product Data

Split System Cooling Product Data

Split System Cooling Product Data

Split System Cooling Product Data XB 1000

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

Hyperion TM Split Systems

Submittal. Single Packaged Heat Pump 15 SEER Convertible 4WCY5024A-SUB-1A-EN. March WCY5024A1000A TAG:

2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil

Illusion Split System

Product Catalog Split System Air Conditioners Odyssey

Product catalog. Hyperion TM split systems 60 Hz / R410A / 13 SEER SSA-PRC009-E4

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080D3PSBA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100U4PSBA TAG:

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 60,000 BTUH S9V2B060D3PSBA TAG:

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:

SPECIFICATIONS 4YCC3060A-SPEC-1A SINGLE PACKAGED GAS HEATING ELECTRIC COOLING 4YCC3060A1096/120B TAG:

36,000-62,000 BTUH Nominal Capacity

4YCC3036A1075B /1/ / YCC3036A1064B /1/ /

Modular Multi-position Air Handler

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

PRODUCT SPECIFICATIONS 2YCC3036A1096A /1/ /

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

4YCC3048A3096A /3/ /

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:

Product Data /4WCC3018A through 2/4WCC3060A Single Package Convertible Heat Pump 13 SEER 1½ - 5 Ton R-22/R-410A

Commercial High-Efficiency Condensing Units

PRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ /

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

Submittal. Single Packaged Convertible Gas/Electric 14 SEER 4YCC4024A-SUB-1F-EN. August YCC4024A1060A TAG:

MACH N-407 Heat Pump Air-Cooled Chiller

2YCC3060A1120A /1/ / YCC3060A1096A /1/ /

Appendix J Noise Appendix

Product Data YCZ6036A through 4YCZ6060A Single Packaged Convertible Gas/Electric 16 SEER 3, 4 & 5 Ton, MBTU R-410A

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:

Vertical Upflow Horizontal Left Air Handlers

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

Cooling/Heat Pump Convertible Air Handlers

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Service Facts. Air Handler - Convertible Model: Series 2 Air Handlers ton GAT2A0B42S31SA GAT2A0C48S41SA GAT2A0C60S51SA WARNING: GAT2-SF-1B

2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½

Transcription:

Submittal Split System Cooling 4A7A6024J1000B Note: Graphics in this document are for representation only. Actual model may differ in appearance. SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. January 2017 4A7A6024J-SUB-1B-EN

Model Base A B C D E F G H J K 4A7A6024J 3 730 (28 3/4) 829 (32 5/8) 756 (29 3/4) 3/4 3/8 127 (5) 76 (3) 197 (7 3/4) 60 (2 3/8) 508 (20) SOUND POWER LEVEL A-Weighted Sound Full Octave Sound Power [db] Model Power Level [db(a)] 63 Hz* 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 4A7A6024J 73 79 69 67 70 70 64 59 53 Note: Rated in accordance with AHRI Standard 270 2008 *For Reference Only 2 4A7A6024J-SUB-1B-EN

Product Specifications OUTDOOR UNIT (a) (b) 4A7A6024J1000B POWER CONNS. V/PH/HZ (c) 208/230/1/60 MIN. BRCH. CIR. AMPACITY 13 BR. CIR. PROT. RTG. MAX. (AMPS) 20 COMPRESSOR DURATION - SCROLL NO. USED NO. STAGES 1 1 VOLTS/PH/HZ 208/230/1/60 R.L. AMPS (d) L.R. AMPS 10.1 52 FACTORY INSTALLED START COMPONENTS (e) INSULATION/SOUND BLANKET COMPRESSOR HEAT OUTDOOR FAN NO (Uses BAYKSKT263) NO NO PROPELLER DIA. (IN.) NO. USED 23.02 1 TYPE DRIVE NO. SPEEDS DIRECT 1 CFM @ 0.0 IN. W.G. (f) 2685 NO. MOTORS HP 1 1/8 MOTOR SPEED R.P.M. 850 VOLTS/PH/HZ 200/230/1/60 F.L. AMPS 0.64 OUTDOOR COIL TYPE SPINE FIN ROWS F.P.I. 1 24 FACE AREA (SQ. FT.) 16.25 TUBE SIZE (IN.) 3/8 REFRIGERANT LBS. R-410A (O.D. UNIT) (g) FACTORY SUPPLIED 5LBS., 3 OZ YES LINE SIZE IN. O.D. GAS (h) (i) 3/4 LINE SIZE IN. O.D. LIQ. 3/8 CHARGING SPECIFICATIONS SUBCOOLING 8 F DIMENSIONS H X W X D CRATED (IN.) 34 x 30.1 x 33 WEIGHT SHIPPING (LBS.) 190 NET (LBS.) 162 (a) Certified in accordance with the Air-Source Unitary Air-conditioner Equipment certification program, which is based on AHRI standard 210/240. (b) Rated in accordance with AHRI standard 270. (c) Calculated in accordance with Natl. Elec. Codes. Use only HACR circuit breakers or fuses. (d) This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size. The value shown is the branch circuit selection current. (e) No means no start components. Yes means quick start kit components. PTC means positive temperature coefficient starter. Optional kit shown. (f) Standard Air Dry Coil Outdoor (g) This value approximate. For more precise value see unit nameplate. (h) For standard, recommended linear length and lift applications, see the Subcool Charging Chart on page 5. For greater lengths and other applications, consult refrigerant piping software Pub. No. 32-3312-xx (xx denotes latest revision). (i) Trane outdoor condensing units are factory charged with the system charge required for the outdoor condensing unit and 15 feet of tested connecting lines. If connecting line length exceeds 15 feet, then final refrigerant charge adjustment is necessary. Each additional foot over 15 feet requires 0.6 lbs of refrigerant. See the Installer s Guide for full charging instructions. 4A7A6024J-SUB-1B-EN 3

Mechanical Specification Options General The Outdoor Units are fully charged from the factory for up to 15 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115 F. Cooling capacities are matched with a wide selection of air handlers and furnace coils that are AHRI certified. The unit is certified to UL 1995. Exterior is designed for outdoor application. Casing Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint finish on all louvered panels and the fan top panel. The corner panels are prepainted. All panels are subjected to our 1,000 hour salt spray test. The base is made of a CMBP-G30 weatherproof material to resist corrosion. Refrigerant Controls Refrigeration system controls include condenser fan, compressor contactor and high pressure switch. High and low pressure controls are inherent to the compressor. A factory supplied liquid line drier is standard. Some models may require field installation. Compressor The compressor features internal over temperature, pressure protection and total dipped hermetic motor. Other features include: Centrifugal oil pump and low vibration and noise. Condenser Coil The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Low Ambient Cooling As manufactured, this system has a cooling capacity to 55 F. The addition of an evaporator defrost control permits operation to 40 F. The addition of an evaporator defrost control with TXV permits low ambient cooling to 30 F. Thermostats Cooling only and heat/cooling (manual and automatic change over). Sub-base to match thermostat and locking thermostat cover. Evaporator Defrost Control See Low Ambient Cooling. 4 4A7A6024J-SUB-1B-EN

Notes 4A7A6024J-SUB-1B-EN 5

Notes 6 4A7A6024J-SUB-1B-EN

Notes 4A7A6024J-SUB-1B-EN 7

Ingersoll Rand (NYSE: IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands including Club Car, Ingersoll Rand, Thermo King and Trane work together to enhance the quality and comfort of air in homes and buildings; transport and protect food and perishables; and increase industrial productivity and efficiency. We are a global business committed to a world of sustainable progress and enduring results. ingersollrand.com Ingersoll Rand has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. 4A7A6024J-SUB-1B-EN 27 Jan 2017 Supersedes 4A7A6024J-SUB-1A-EN (October 2015) 2015 Ingersoll Rand all rights reserved