Panel Functions & Indicators - Key to Icons General & Zone Fire LEDs ACCEPT SOUNDERS START/ STOP RESET BUZZER MUTE KEYSWITCH DELAY ON/OFF ITEM SELECT

Similar documents
USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

User Operation Manual

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

USER MANUAL & MAINTENANCE GUIDE OG OO

Intelligent Security & Fire Ltd

Fire Alarm Control Panel. System Maintenance and Log Book

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

SYSTEM 5000 USER MANUAL

ID2000. operating manual

FIRE ALARM CONTROL PANEL FVC01-08

Conventional Fire Alarm System 2014 V1.2

Installation, Operating and Maintenance Manual

Document No Issue 4 user manual

Scimitar user manual & log book. Petersfield Business Park, Bedford Rd, Petersfield, Hampshire GU32 3QA Tel: Fax:

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

PAT E N T System 88. COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Noby-448 User Operating Manual & Log Book Page 1 of 12. Fire Control Panel. User Operating Manual & Log Book

Intelligent Security & Fire Ltd

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

Sigma XT. Extinguishant Control Panel. User Manual Man-1091 Issue 03 October 2009 (K11031M2, K11031F2)

SYSTEM 3400 ANALOGUE ADDRESSABLE FIRE DETECTION. (with Devices) Operating Manual Version 3.3X Issue 2 September 1996

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

CSP-204 CSP-208 CSP-104 CSP-108

user manual Document No , Revision 03 November 2015

Intelligent Security & Fire Ltd

Firetrax Professional Conventional Fire Control Panel

Intelligent Security & Fire Ltd

Operating instructions SENTRI4 Control panel based Fire detection and alarm system

ZERIO PLUS EDA-Z5008, Z5020 & Z5100

ZP2 Series Operation Manual

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

CHECKFIRE 110 DETECTION AND ACTUATION SYSTEM

Fire Control Panel. Installation & Programming Manual TABLE OF CONTENTS

Operating instructions Vigilon panel and Network node Fire detection and alarm system

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

Algo-Tec 6500/6600 INTERACTIVE ADDRESSABLE FIRE CONTROL SYSTEM

Conventional & Twin-wire Fire System

Logbook. Precept EN Fire Detection/Alarm Panel. & Precept EN Repeater

Syncro Matrix Analogue Addressable Fire Alarm Mimic Panel Product Manual

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

KFP-CF Series Operation Manual

EX8. Instruction Manual: COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 AND EN54 PARTS 2 & 4

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

Conventional Fire System. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI User Manual

Saffire User & Installation Manual. IMPORTANT This manual should be left with the panel after installation.

Control Panel User Guide

Operator's Handbook. Interactive Fire Alarm System Release 3. Information Panel, BV-320. Protecting life, environment and property...

FIRE BRIGADE RESPONSE GUIDE. LoopSense. Fire Alarm Control Panel (AS4428 & AS & 4) Operation & Onsite Programming MAN

EP203. User Manual and. Approved Document No. DFU Rev 1

OPERATION AND INSTALLATION MANUAL

XFP NETWORKABLE ANALOGUE ADDRESSABLE FIRE ALARM CONTROL PANEL. user manual and log book. approved document no. DFU Rev 1

909e Series 2/4 Zone Panel. Operating and Configuration. Manual Version V01

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections.

Application, Installation, Operation & Maintenance Manual

one Operating instructions SenTRI ONE panel-based Fire detection and alarm system

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

Operator's Handbook. Release 3. Fire Alarm Control Panel, BS-310 / 320 / Operator Panel BS-330. System Program Version 3.8.0

VSN-RP1r Extinguishing Control Panel. User Manual (Software version 3.x) by Honeywell. doc. MIE-MN-570I rev.008

JUNO-NET. Fire Alarm Control Panel OPERATION & MAINTENANCE MANUAL

Control Panel User Guide

Racal-Guardall. Countess. User Instructions. Countess

NFS Supra / VSN-2Plus / ESS-2Plus Conventional Fire Alarm Control Panel. Installation and Operating Manual

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

ZP3 Operator & Maintenance Manual Version 1

636 and 646 Keypads. User s Manual

ZSC100 Gas Detection and Alarm System Controller

HILLS Series LED Code Pad User Manual

PROFYRE C8 USER MANUAL, MAINTENANCE GUIDE & LOG BOOK FIRE ALARM CONTROL PANEL USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

Fire detection and alarm system Operating instructions

user manual and log book XFP NETWORKABLE ANALOGUE ADDRESSABLE FIRE ALARM CONTROL PANEL

Excel-EN Conventional Fire Control Panel

Fire Alarm Control Panel EN54 2 & Operation & Programming MAN

SIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL

PREMIER EX8 INSTALLATION MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4 INSTALLATION MANUAL

ORION Mini-Rep INSTALLATION MANUAL

SFC-200 SERIES LED FIRE ALARM PANEL

VICTORIAN RESPIRATORY SUPPORT SERVICE AUSTIN HEALTH

NetworX NX-8V2. LED Keypad User Manual

SECURIT 700L USER MANUAL

Conventional Leaflets

RP1r-Supra / VSN-RP1r+ / ESS-RP1r-Supra Extinguishing Control Panel User Manual. HLSI-MN-103I v.06 September 2017

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

Surveyor Excel. Fire Alarm Control Equipment Network version. Programming Manual MASTER MANUAL. VERSION 14.0 and Above

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

NETWORX TM. User manual NX-4

MAG2/4. AL MAG2 Soft. Version 2.1 MAG4 Soft.Version 2.0 USER MANUAL

Door Release Power Supply

FEC403EN Installation Manual

NX-148 LCD CODE PAD TABLE OF CONTENTS

Transcription:

Islenska Français Deutsch Nederlands Svenska EN54-8 Zone Conventional Fire Control Panel User Manual 997-493-00, Issue 0 November 003

Panel Functions & Indicators - Key to Icons General & Zone Fire LEDs ACCEPT SOUNDERS START/ STOP RESET BUZZER MUTE KEYSWITCH DELAY ON/OFF ITEM SELECT Zone FAULT/ DISABLE/ TEST LEDs System LEDs LAMP TEST DISABLE/ TEST/ NORMAL Contents Introduction Panel Indicators & Controls Indicators Controls 3 FIRE - What do you do? 3 4 Sounders - How to Stop/Start 3 5 FAULT - What do you do? 4 6 TEST /DISABLEMENT Functions (Access Level ) 4 6 Lamp Test 4 6 Test/ Disable Options 5 6 3 Delay On/Off 6 7 Maintenance 6

Introduction Only authorised and suitably-trained personnel must carry out procedures in response to fire alarm events or perform scheduled test and maintenance activities This manual contains operating instructions for the EN54, - 8 zone conventional fire control panel All the control and operation functions described in this manual can be carried out using the pushbuttons on the front of the panel Users of this manual are assumed to be working with a panel that has already been installed and configured appropriately for the area under its supervision Panel Indicators and Controls The panel s indicators display the panel status and the controls are used to operate the overall system The panel has up to eight zonal LED indicators, a FIRE indicator, thirteen system status LED indicators and eight function pushbuttons Indicators The location of the panel s indicators is shown below: FIRE - The following red status indicators are provided: General Fire and 8 Zone Fire LEDs FAULT - The following yellow status indicators are provided: Fault /Disabled /Test and 8 Zone Fault /Disable /Test LEDs SYSTEM - The following 3 status LEDs are provided: Power available - mains and/or battery G General Fault; General Disablement; General Test; Delay On (active); System Fault; Earth Fault; Power Supply Fault; Sounder Fault /Disabled; Fire Routing Fault /Disabled; Fault Routing Fault /Disabled; Auxiliary Fault Y Fire Brigade Called /Fire Routing Output Active R Note: Yellow LEDs: Red LEDs: Flashing - Fault; Steady - Disablement Flashing - New alarm; Steady - Accepted alarm 997-493-00, Issue

Buzzer This activates with panel status change, i e through FIRE or FAULT condition When active the buzzer indicates the highest priority condition, e g FIRE over FAULT Push-button operation is confirmed by a brief audible buzzer action Controls The position of the panel s controls and keyswitch is shown below: The access Level of the panel s controls is indicated,,, Keyswitch A keyswitch provides access to the Level control functions Insert the key and turn clockwise through 90 Access Level and control functions are described below Other Controls: Access Level - changes any flashing indications of new zones in fire to steady indications of confirmed zones in fire, mutes the buzzer and extends any delay Access Level - changes (mutes) operation of internal buzzer; changes flashing indications of new zones in fire to steady indications of confirmed zones in fire Access Level - ends an active delay and activates any configured outputs Access Level - with no delays active - toggles the delay mode Access Level - with panel in a quiescent state - activates all sounders for EVACUATE 997-493-00, Issue Access Level - returns panel to its normal quiescent condition; test and disablement modes are not affected and remain active after this selection Existing fire conditions are re-indicated within 3 secs and/or any fault conditions within 00 secs Access Level - used with to select disablement and test mode selections See Section 6 TEST/DISABLEMENT Functions Access Level - used with to cycle though normal, disablement or test states of selections See Section 6 TEST/DISABLEMENT Functions Access Level - illuminates all LEDs and operates internal buzzer

3 FIRE - Red LED Indication - What do you do? No delays configured: Status: - Flashing - Steady tone - Operating Action/Result: Press to silence the buzzer and change LED to steady With configured delay: Status: L - Press buzzer the - Flashing Action/Result: - Flashing:st stage - Steady tone to silence the and change LED to steady - the LED flashes; press to end delay L - Press to extend delay 4 Sounders - How to Stop/Start To stop/start sounders: Status: - Flashing - Operating,,3 - Steady tone Action/Result Insert key and turn 90 clockwise Press Sounders stop operating 3 Press again to resound sounders 3 997-493-00, Issue

EN54-8 Zone Conventional Fire Panel - User Manual 5 FAULT - Flashing Yellow LED Indication - What do you do? Status: - Flashing - Intermittent tone Action/Result: Press to mute buzzer ; LED continues flashing Investigate cause of fault - contact service engineer 6 TEST/DISABLEMENT Functions (Access Level ) - Steady Yellow LED Indication Caution: If the System Fault LED is lit steadily your building may not have fire protection - contact service engineer immediately! 6, 3 Insert key and turn 90 clockwise for Level access Lamp Test Insert and turn key 90 clockwise to enable access Level controls Press and hold : the following LEDs illuminate:, and The buzzer activates 3 Release to extinguish LEDs, and and silence the buzzer 4 Turn key 90 anticlockwise: returns you to access Level 997-493-00, Issue 4

6 Test/ Disable Options 3 3 4 The test and disablement options available are tabulated below TEST or DISABLE status change method for single zones is described Follow the same procedure to change status of other setup options Insert and turn key 90 clockwise to enable access Level controls To step through setup options -6, press to illuminate LEDs Flashing LED indicates current selection, e g Zone 3 Press to select NORMAL, TEST or DISABLEMENT status - confirmed by LED indication change 4 Repeat steps & 3 as required to make other changes 5 Turn key 90 anticlockwise: returns you to access Level and saves all changes The LED is lit steadily 6 To cancel status change, repeat steps to 5 to extinguish the LEDs able ALL zon 4 5 997-493-00, Issue

6 3 Delay On/Off Delay countdown pattern of flashing follows buzzer - unaffected by MUTE BUZZER Last 5 secs of delay, pulsing of buzzer doubles to warn of imminent delay end Insert and turn key 90 clockwise to enable access Level controls Press The DELAY ON LED lights 3 Turn the key 90 anticlockwise: retuns you to access Level and saves selection LED is lit steady 4 To cancel, repeat procedure to extinguish LED 7 Maintenance Create a log book with reference data (see below) and event data (refer to page layout at back of this manual) Use this log book to record all maintenance test results and details of any faults or problems that arise Enter details of the maintaining company The responsible person should ensure that functional tests are performed daily, weekly, quarterly and annually: daily - check for normal operation; weekly - testing of at least one sensor/mcp/zone to check panel and audible alarms; quarterly checks - log book entries/actions, battery state/charger voltage, remote manned centre links plus perform weekly tests; annually - test all devices and perform visual inspection of cable fittings and equipment Reference Data Name & Address Responsible person Date Date Date Date The system was installed by and maintained by Tele No Cleaning The panel case may be cleaned periodically by wiping with a soft, damp lint-free cloth Do not use solvents 997-493-00, Issue 6

997-493-00, Issue Event Data