Ceiling office High-performance Radiant Ceiling Systems

Similar documents
CLIMAV 2.0 Thermoregulation Systems

Radiant Systems Catalogue Price List

b!klimax Ceiling and Wall Radiant System. Innovative Wellbeing.

b!klimax radiant wall/ceiling system

Line. Floor Heating and Cooling Systems

Hydronic Heating Fan Coils Radiant ceiling systems Water Source Heat Pumps Alumline Radiant Heating and Cooling Ceiling Panels

INTRODUCTION HOW DO RADIANT PANELS WORK? A common misconception, even among heating professionals, is that heat rises. In fact, hot air rises and cold

Intelligent Temperature Management. ThermaCool - Say goodbye to inefficient temperature peaks. GeoClima Inclusive Technical Package

Modula Standard Performance

Ray Magic Quad Metal panels for suspended ceiling

raymagic quad Installation, Operation & Maintenance Manual

product catalogue idealairgroup.com.au idealairgroup.com.au

PRE-ASSEMBLED RADIANT CONTROL PANEL INSTALLATION MANUAL

A NEW BEGINNING IN FAN COIL HISTORY

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation

Cooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation

UNDERFLOOR HEATING GUIDE

Metal and textile perforated air ducts. ONEAIR SRL - All rights reserved. Unauthorized reproduction is forbidden.

Heating Systems for Museeum and Worship Places

Galletti IWC THE HYDRONIC CASSETTE UNIT PAR EXCELLENCE A guide to choosing Create value to design better

CHAP. 01 PAGE 6 CHAP. 02 PAGE 32 CHAP. 03 PAGE 71 MECHANICAL VENTILATION

CALEFFI. Modulating temperature regulating unit for heating and cooling with high temperature distribution kit. series /04 GB.

RADIANT HEATING AND COOLING SYSTEMS Produced by FRENGER SYSTEMEN BV

SPIDER P SPIDER P mineral

KLIMA Active Chilled Beams

WEAVE RADIANT TEXTILE PANEL. Credit Reimann Architecture

Static cooling ceiling system SKS-4/3 DS 4094 E /1. Technical Selection

CHILLED & HEATED CEILINGS

Heating and cooling ceiling systems Suspended ceiling systems. Heating Cooling Fresh Air Clean Air

The heart of electric appliances ELECTRIC WATER HEATING MADE IN ITALY

SECTION RADIANT HEATING UNITS

r lo o c d n a s re tu x e T

COOLING and DE-HUMIDIFICATION WITHOUT USING REFRIGERANTS

SOLAR TECHNIQUE ATTACK SOLARTHERM, VAKUUMTHERM

Steam Humidification Light Commercial Applications. Better technology means better business.

Carat. Chilled beams. Use. Worth noting. Installation. Key figures. lindab chilled beams

NEW AR-L AR-C AND HIGH-CAPACITY LINEAR COOLING PANELS. Higher energy efficiency. Increased thermal comfort

Energy. The Energy ducted units have been designed. Heat Recovery Unit

=Classic range= Classic range technologies. Magnesium anode. Sheathed heating element

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

Systems for central heating

D. Fabrication: Steel or Aluminum with baked enamel off-white finish. B. Type: Square and rectangular, adjustable pattern, multi-louvered diffuser.

RADIANT PANELS COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING

Outdoor Enclosures. Outdoor Enclosures Protected like a bunker for all harsh environments

Helios. Unit Heater. Thickness 1 mm. Diameter 22 mm. Pitch 2,5 mm. Fin 0,12 mm

Type PWX HORIZONTAL CHASSIS TYPE WATERSIDE FANCOILS FOR CONCEALED OR EXPOSED INSTALLATIONS

Low Temperature Radiator GB 01. Heating & Plumbing. Ideas to install

SkyStar SK. Cassette Fan Coil Unit with Asynchronous Motor

Metal Coil Drapery. Technical Data. The content includes: BOEGGER. Spectifications Optional color Typical application.

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

ACCREDITED. Product range Code A2L Pre-assembled set point temperature regulating unit with manifolds and box, with UPM3 Auto L pump

RADIANT PANELS COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING

Heating and Cooling Ceiling Systems Comfortable and energy efficient. Heating Cooling Fresh Air Clean Air

OVEN LINE. Roto Bravo rack oven for bread and pastry

Air distribution systems. Opticlean OC-Q... DS 4136 E /1

INFRARED RADIANT GAS SYSTEMS FOR THERMAL TREATMENTS

SOLAR THERMAL SYSTEM. Product catalogue

Industrial infrared heater IR

OVENS LINE. Pocket 4060 rack oven for bread and pastry

Optima Compact Touchscreen Swimming Pool Heater with Ultra Efficient Titanium Heating Elements 3-kW to 24-kW

Contact, Overview, Index. Ceiling Heating/Chilled. Plexus. Professor. Pilot. Architect. Polaris I & S. Plafond. Podium. Celo. Cabinett. Capella.

Metal Cassette Ceiling with BEKA Heating and Cooling Mats

Customers. The core of our innovation. Feeding&Conveying. Drying Dosing Temperature Control Refrigeration Granulation

FIRST Heating. Company and product overview

WHAT - HOW - WHY - WHERE PROTERCEILING RADIANT CHILLED CEILINGS COMFORT - EFFICIENCY - SAVINGS - AESTHETICS

Data Centre Cooling Solutions

FLEXIBLE METAL - BENDING THE RULES OF PLUMBING CONNECT WITH CONFIDENCE SEE OUR NEW EXTENDED RANGE OF VALVES -

Radiant Ceiling. Metawell Klimadecke 1

SOLAREKS. Natural Circulated Closed Loop System SOLAREKS

Zehnder Carboline Radiant Heating and Cooling Ceiling Panels. Cooling Fresh Air Clean Air

Zehnder ZIP Radiant Ceiling Panels

Radiator Valve Program

FIREPLACE INSERTS. SINCE 1960

Easdale International INFINITY

Data Centre Cooling Solutions

Optimal work climate with open doors. Industrial air curtains Model IndAC

Agriculture Cultivation protection

RAUBIOXON PLUS AND RAUBIOFLEX ADVANCED AERATOR SYSTEMS. Construction Automotive Industry

H o t Wa te r Syste m s. Senator Electric Flow Boilers. Making Life Simpler

Ceiling diffusers. Type DLQL

Technical Sheet. Hybrid concealed radiator System Insulated Rubber Pipe

Hydronic Radiant and Snowmelt. Product Catalog. Living full of energy

caleffi hydronic valves page 1 of 12

JH Series Installation

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

METALWORKS. Airtite Panels. Radiant Ceiling Systems

WE RE FLEXIBLE BY DESIGN. At QPI, we ll tailor our services to satisfy your most demanding design projects.

messana system Thermal Wellbeing comes from above

Krantz. Multifunction exposed ceiling AVACS. Cooling and heating systems

Carbon Fibre Heating Technology Heating Systems for Industrial Use

Towel Warmers Electric Rad catalogue

BEKA ceiling heating versus traditional underfloor heating

Fibreglass reinforced polyester (FRP) water collection basin with sloping base and smooth internal finish with rounded corners for easy cleaning.

C OLOU R S & FI NI SH

Thermal Wellbeing comes from above

Series 4. Rotary rack oven. For pastry chefs and bakers, Series 4 rotary rack ovens concentrate a range of technology to ensure real benefits:

Heating Installation Guide published by

Sargasso Range. A new range of radiant panels for heating commercial applications

700 & 900 RANGE EFFICIENT RELIABLE INNOVATIVE

INFRA-RED BURNERS BR-70 SERIES FEATURES APPLICATIONS. Bulletin E3005 rev03 31/01/00

Transcription:

Ceiling office High-performance Radiant Ceiling Systems EN

TIEMME, INNOVATION FOR A STEADY GROWTH Tiemme Raccorderie is an international leader in the production and marketing of plumbing and heating components. Experience, innovative capacity, creativity and exclusive Made in Italy production, tradition and culture, attentive customer care and environmental consciousness are the key values from which Tiemme creates solutions for plumbing and heating system engineering, in a perfect mix of technical competence and top material quality. That allowed Tiemme to develop through the years an extensive catalogue of products introducing itself to the world of systems engineering as an all-in-one supplier, able to meet the most diverse demands of the plumbing and heating industry. Tiemme prides itself in keeping the entire production chain on national territory so as to ensure high quality, unquestionable safety and reliability of its products and systems Each year, Tiemme also invests considerable resources in the research and development of new solutions so as to anticipate the requests of an increasingly global market.4,000,000 metres of PE-X extruded oxygen barrier tube. 3

RADIANT CEILING SYSTEM WIDESPREAD WELL-BEING The ceiling heating system distributes heat in all the rooms of a house through a principle of exchange by radiation between hot surfaces and cold surfaces. What is this? Irradiation is the phenomenon that frequently occurs in nature when a surface absorbs the heat contained in or generated by a surface with a relatively higher surface temperature. Similarly, the walls of a room which the ceiling heating system is located in represent the cold surface and accumulate the heat generated by the suspended ceiling, distributing it in turn into the surroundings and heating it. 4

WHY CHOOSE A RADIANT CEILING SYSTEM? 1 It does not require masonry works A ceiling heating system is a cheap solution, because the installation of radiant panels does not require demolitions or other masonry works. 2 Homogeneous heat The ceiling heating system provides homogeneous heating and allows balanced exchange between the environment and the radiant system. This prevents from thermal shock. 3 4 5 6 Practical installation and flexible usage Radiant panels are pre-built and assembled, and are perfect for producing both heat during cold periods and cool in warmer time. Reduced dimensions Radiant ceiling panels are an invisible heating system and occupy minor space. They are less than 50 mm thick and their installation does not imply restrictions the space in which they are located. Wide architectural compatibility The ceiling heating system is highly modular and integrates perfectly with the architecture, so that panels can fit any type of ceiling. Reduced humidity, mould, and off-odours Heat is spread by thermal exchange, thus reducing humidity, mould, and off-odours. This is extremely favourable in the northern areas of the house, where unwanted microorganisms are likely to thrive. 22 C 24 C 22 C 40 C 20 C 16 C 18 C Radiator heating system Ceiling heating system 5

TIEMME FOR THE TERTIARY Tiemme has developed a line of ceiling radiant systems that is perfect for offices, schools, businesses or any other situation related to the tertiary sector. The systems department of Tiemme specializes in designing and consulting for the tertiary sector, guaranteeing support from the early stages of design to the selection of the most suitable products, from the transition to the executive phase to on-site assistance. 6

CEILING OFFICE CEILING OFFICE specific solution for residential and commercial heating and cooling systems where a maximum thermal yield is required without any surface temperature restrictions. 1 2 3 4 5 1 Insulation: polystyrene (from catalog) - mineral wool - polyester fiber - biocompatible - packaged wool 2 Aluminum diffuser 3 PE-X piping with 8x1mm oxygen barrier - availability of piping in copper 4 TNT - non-woven fabric 5 Steel finish (from catalog) metal or plaster variants available, highly customizable in sizes, colors, and materials in order to satisfy any aesthetic need. 7

CEILING OFFICE Specific solution for residential and commercial heating and cooling systems where a maximum thermal yield is required without any surface temperature restrictions. 4 3 2 5 1 1 Metallic square 2 Serpentine 3 Polystyrene 4 Insulated Pex pipe Ø 8x1 8

CEILING OFFICE / PANEL SK600_PL Radiant micro-perforated aluminum panel for ceiling radiant systems with white colored polystyrene insulation layer Codes Code Size Unit/Box 450 0493 600 x 600 mm on demand Technical characteristics SK600 panel technical features 450 0168 Insulation thickness [mm] 30 Total thickness [mm] 31 Thermal conductivity UNI EN 12667 [W/mK] 0,0389 Thermal resistance EN 13163 [m²k/w] 0,86 Reaction to fire EN 13501-1 Euroclass E Total panel size [mm] 600 x 600 Panel surface [m²] 0,6 Panels per package [n] on demand Panel surface per package [m²] on demand Thermal yields of radiant panels according to UNI EN 15377* 200 190 180 170 160 150 140 130 120 Ceiling heating Ceiling cooling θ [K] Temperature difference between the average temperature of the radiant surface and the temperature of the ambient air * Performances certified by the Department of Technical Physics of the University of Padua, Italy Specifications Active radiant panel 600 x 600 mm, on the ceiling, for summer and winter cooling systems at low temperatures consisting of: Metallic panel in white-colored micro-perforated aluminum, thickness of 0.6 mm; Insulation layer in 30-mm expanded polystyrene, conductivity 0.0389 W/mK according to UNI EN 12667; Plastic 8x1-mm coil made of PE-Xb b.o. that complies with EN 15875 with oxygen-free barrier according to DIN 4726; Aluminum diffusers for improved heat exchange. 9

CEILING OFFICE / OTHER COMPONENTS SK600_PLN Micro-perforated aluminum infill panel for ceiling radiant systems, white-colored, non-insulated 5580 Straight fitting with quick coupling in polyamide for PEX tube 8x1 mm Code Size Unit/Box 450 0494 600 x 600 mm on demand Specifications. Aluminum infill panel 600 x 600 mm for radiant ceiling systems consisting of a white-colored micro-perforated aluminum metallic panel, thickness of 0.6 mm. 0200BR High density cross-linked polyetylene pipe with anti-oxygen barrier (EVOH). White colour. In rolls Code Size Unit/Box 556 0149 8 x 8 mm 10/50 Specifications. Straight quick coupling fitting for PEX tube 8x1.0 mm consisting of: Body in nylon 6,6 loaded with 30% glass fiber, resistant to hydrolysis; Stainless steel; Double OR in peroxygen EPDM; Operating temperature: max 80 C continuously at 2 bar, max 120 C for peaks; Operating pressure: max. 8 bar at room temperature. Code Size Unit/Box 450 0391 8 x 1,0 mm 10 m 5580TAP Closing cap in polyamide for articles 5580C, 5580T and 5580 5580T Tee distributor 20x8x20 mm with quick coupling in polyamide Code Size Unit/Box 556 0147 20 x 8 x 20 mm 10/50 Specifications. Straight quick coupling distributor for PEX tube 8x1.0 mm consisting of: Body in nylon 6,6 loaded with 30% glass fiber, resistant to hydrolysis; Stainless steel tweezers; Double OR in peroxygen EPDM; Operating temperature: max 80 C continuously at 2 bar, max 120 C for peaks; Operating pressure: max. 8 bar at room temperature. Code Size Unit/Box 556 0152 8 x 1 mm 10/50 556 0150 20 x 2 mm 10/50 Specifications. End-of-line cap for closing lines on quick-fit fittings consisting of: Body in PA6.6; Operating temperature: max 80 C continuously at 2 bar, max 120 C for peaks; Operating pressure: max. 8 bar at room temperature. 3670 Y filter for impurity 5580C Double line distributor 20x8x8x20 mm with quick coupling in polyamide Code Size Unit/Box 367 0002 1 10/30 367 0005 1 1/4 4/16 367 0009 1 1/2 3/12 367 0004 2 2/8 Code Size Unit/Box 556 0148 20 x 8 x 8 x 20 mm 10/50 Specifications. Straight quick coupling distributor for PEX tube 8x1.0 mm consisting of: Body in nylon 6,6 loaded with 30% glass fiber, resistant to hydrolysis; Stainless steel tweezers; Double OR in peroxygen EPDM; Operating temperature: max 80 C continuously at 2 bar, max 120 C for peaks; Operating pressure: max. 8 bar at room temperature. 5570 Micro bubbles deareator, made of brass, stainless steel PALL rings for radiant systems Code Size Unit/Box 556 0001 3/4 on demand 556 0002 1 on demand 556 0003 1 1/4 on demand 556 0004 1 1/2 on demand Specifications. Air separator suitable for radiant systems, made of brass, completed with PALL stainless steel ring, conical air chamber and adjusting screw. 10

CEILING OFFICE / OTHER COMPONENTS 4539 Protective against corrosion of metal parts with Universal germicide for heating and cooling systems N.B. It is advised to use 1 lt of protective every 100 lt of circulating water. Code Size Unit/Box 450 0486 1000 ml 1/12 Specifications. Liquid chemical protective additive against corrosion of metallic parts with universal fungicide bactericide for heating and cooling systems. 11

CEILING OFFICE CUSTOM SOLUTIONS CEILING OFFICE / OFFICE ALU EPS insulation with GRAPHITE for maximum thermal performance Drywall, thickness 15 mm Tubing, 8x1 mm Pitch, 30 mm or 50mm Aluminum diffusers in the ALU version CEILING OFFICE GEX / OFFICE GEX ALU EPS insulation with GRAPHITE for maximum thermal performance Drywall, thickness 15 mm Tubing, 8x1 mm Pitch, 30 mm or 50mm Aluminum diffusers in the ALU version CEILING OFFICE GEX SILENT / GEX ALU SILENT EPS insulation with GRAPHITE for maximum thermal performance Drywall, thickness 15 mm Tubing, 8x1 mm Pitch, 30 mm or 50mm Aluminum diffusers in the ALU version 12

CEILING OFFICE CUSTOM SOLUTIONS CEILING OFFICE GEX FIRE / GEX ALU FIRE EPS insulation with GRAPHITE for maximum thermal performance Drywall, thickness 15 mm Tubing, 8x1 mm Pitch, 30 mm or 50mm Aluminum diffusers in the ALU version Project design requirements that require certain acoustic requirements are satisfied with Tiemme SILENT solutions, which can be combined with the CEILING HOME and CEILING HOME ALU radiant systems. The Tiemme acoustic system is obtained through a layer of perforated drywall coupled with visible acoustic felt and thick rock-wool in which the thickness can be defined by the designer. By request, Tiemme can supply radiant panels with specific fire reaction requirements. Fire reaction class of the surface layer using special drywall up to class A1. Fire reaction class of the insulating layer using mineral wool up to class A1. EXAMPLES OF POSSIBLE CONFIGURATIONS Panel in smooth plaster Panel in perforated plaster Plaster panel with a centered hole Plaster panel with rectangular slots Plaster panel with rectangular slots 13

CEILING OFFICE CUSTOM SOLUTIONS CEILING OFFICE METAL EPS insulation with GRAPHITE for maximum thermal performance, rock-wool, mineral wool as requested Metal panel in steel or aluminum in dimensions, colors, and finishes that are completely customizable Tubing 8x1 mm Pitch, 30 mm or 50mm Aluminum diffusers in the ALU version 14

CEILING OFFICE CUSTOM SOLUTIONS Circuits available in copper for a complete customization of the internal piping of the panels. The perfectly calibrated copper pipe in the requested diameter is housed within the metal diffuser for high thermal performance. 15

CEILING OFFICE COMMERCIAL APPLICATIONS EFFICIENT SOLUTIONS THAT CAN INTEGRATE WITH A MODERN BUILDING. WE GUARANTEE A HIGH LEVEL OF COMFORT. Applications in heating and cooling that, thanks to the microboring of the modules, increase heating and cooling performance and guarantee a high level of comfort. WE LL TAKE CARE OF THE MAINTENANCE Thanks to the inspectability of each panel, maintenance becomes much easier. It is also possible to intervene with a serviceable system. 16

CASE HISTORY MENSA INDUSTRIA BRESCIANA INSPECTABILITY OF INSTALLATIONS. HIDDEN METALLIC SUPPORTING STRUCTURE. MODULARITY OF THE ELEMENTS. 17

CASE HISTORY JUVENTUS DIRECTIONAL CENTER 18

TIEMME RACCORDERIE S.p.A. Via Cavallera, n. 6/A - 25045 Castegnato (BS) - Italy Tel. +39 030 2142211 - Fax +39 030 2142206 info@tiemme.com Customer Service Fax +39 030 2142254 customerservice@tiemme.com www.tiemme.com 9 9 0 0 6 7 8