Fundamentals of Insulation and their effect on buidling sustainability

Similar documents
THERMAL & ACOUSTIC INSULATION FOR RAILWAY VEHICLES

DualGuard Fluoropolymer Barrier FRP Duct. Composites USA. Fluoropolymer Barrier FRP Duct. A Critical Process Systems Group Company LISTED

FACADES AND FIRE The Essential Elements

Market-Leading Non-Metallic Enclosure Brands

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

IMO Resolution MSC 61(67): Annex 1: Part 2

ASTM F25 SEMINAR Fire Testing for SOLAS and Navy Vessels New Test Procedures and Materials Approval Process

Review Fire Test Report

Setting the Standard in Third-party Certification

Smoke detection in hazardous areas:

FIRST-CLASS IN TRAINS

Global Requirements for the Fire Protection of Ships. Dr Janet Murrell Warrington Certification Ltd

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

FIRE TESTING SERVICES FIRE TESTING SER

Belcom Cable excellence engineered through quality. CPR Construction Products Regulation

Abrasion Resistance of Fluoropolymer and polyester Coatings

KoolthermTM. Technical Data. HVAC & Building Services Pipe Insulation

Third Party Certification:

PPE Global Market Access Program

BS EN ISO : 2010

Facts about insulation and fires 29 October 2014

HazLoc Essential Guides:

Second Revision No. 1-NFPA 90A-2016 [ Section No ] Submitter Information Verification. Committee Statement

CPD Seminar: Importance of Reaction-to-Fire Properties of Materials: Combustibility, Spread of Flame and Smoke Generation

Energy Efficiency Schemes Brief Introduction

Fire Risk and CODE Compliance For Fabric Wrapped Acoustic Panels

DNVGL-CP-0399 Edition March 2016

Test Report No. AJD Date: JUN.09, 2013 Page 1 of 6

ASSOCIATION POUR LA CERTIFICATION DES MATERIAUX ISOLANTS

FRANCE M & F RANKING ACCORDING TO NF F

FIRESTOP INSPECTION. Dr. Selina LIN. Technical Manager August 01, FS Inspection 1

UL Test Methods for Determining the Combustibility Characteristics of Plastics Used in Semiconductor Tool Construction. General Information

fire resistant cables

DNVGL-CP-0401 Edition February 2016

BS EN ISO : 2010

DR AS 5389:2016 Space heating and cooling and ventilation systems Calculation of energy consumption. The physical testing

THE TRUE FIRE SURVIVAL CABLE

CERTIFICATE OF APPROVAL No CF 5635 P3 SRL

GUIDELINES FOR THE APPROVAL OF EQUIVALENT FIXED GAS FIRE-EXTINGUISHING SYSTEMS, AS REFERRED TO IN SOLAS 74, FOR MACHINERY SPACES AND CARGO PUMP-ROOMS

+ = FIRE LABORATORY INTRODUCTION. APPLUS+ LGAI - Our company history. High Technology Knowledge. Customer Confidence. Branding

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

PRESSURE-SENSITIVE TAPE CLOSURE SYSTEMS FOR USE WITH FACTORY-MADE AIR DUCTS- STANDARDS UL 181A AND UL 181B

Aerospace Industry. Steel Industry Paper Industries. Infrared Heaters. Complete Engineering Solutions


Fire Protection Industry

Reference to the Smoke Damage Index (SDI) is needed as it is part of the test method.

STEEL DUCT - FIRE RATED CLADDING INSTALLATION MANUAL

Fire Safety Compliance

PRODUCT INFORMATION. GM901 Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING AND PROCESS CONTROL. In-situ Gas Analyzers

BS EN ISO : 2010

FOGTEC Rail Systems. Rolling Stock Applications. Fire Protection Solutions from one source. Leading in Fire Protection. designed for rail 1

II Brazilian Sprinkler Conference October 27-28, 2016

The element is closed at one end and open at the other, and it s bolted onto the explosion vent opening on the equipment so that its open end overlaps

Üntel is ready for CPR

Passive protection against hydrocarbon hazards

CERTIFICATION SAFETY & BEYOND

A2L Refrigerants. Objectives 14/09/2017

The Worldwide Use of Fire Sprinklers

European Council approves EU 3rd RDE Work package; Sensors' SEMTECH CPN meets new demands

FM Approval Standard For Cavity Walls And Rainscreens

TOP TEN 2018 Energy Efficiency Technologies for the U.S. Building Sector

Water Mist Fire Protection Systems for the Protection of Industrial Oil Cookers. 8th March 2016 Dr Tim Nichols CPhys MIFireE

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Tile-diy LLC

Saving lives with coatings

Significance of the Construction Products Regulation, including for data centers WHITEPAPER

C-01 FIRE DECKS AND BULKHEADS

CERTIFICATION BULLETIN

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5

Nuclear Power Plant LSZH Cable Overview

BUSINESS PLAN CEN/TC 301 ROAD VEHICLES EXECUTIVE SUMMARY

Are Your Kitchen Hood Filters Compliant?

EnviroScape Mural. pre-pasted printable wallcovering material. Choose your GREEN resource from a leading solutions provider.

Passive fire protection. 6 Passive fire protection. 6.1 Fire compartmentation. Passive fire protection


Achieving Functional Safety with Global Resources and Market Reach

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

Radio Frequency Heating Systems

(a) Flame shall not spread to the outer extremities of the sample on the 8 ft 12 ft (2440 mm 3660 mm) wall. Flashover shall not occur.

DID YOU GET USED TO THE NEW CPR? HERE S A QUICK REVIEW!

Contents: 4. Report of Surface Burning Characteristics Tests on LP FlameBlock/BlazeGuard (30-minute test) Updated April, 2010

YOUR GUIDE TO UNDERSTANDING CPR

PASSIVE FIRE PROTECTION FTI-MARNEROS LTD

Compilation of regulatory approaches used in various countries. Information received by the Secretariat through a survey in 2009

Chapter 17, Initiating Devices

In Search of Standard Reference Materials (SRMs) for ASTM E05 Fire Standards by. Norman Alvares & Harry Hasegawa

Rol van ISSeP als sectoraal operator

DUST EXPLOSION CODES AND STANDARDS: Ensuring Regional Compliance and Global Consistency

We Identify and S.T.O.P. Your Noise Problems

BUSINESS PLAN CEN/TC 79 RESPIRATORY PROTECTIVE DEVICES EXECUTIVE SUMMARY

Classification of Fire Performance of Wall and Ceiling Lining Materials

Report Of Surface Burning Characteristics Tests On Felt Material As Submitted By Rieke Office Interiors

Fire Testing of Foams

Report Of Surface Burning Characteristics Tests On PVC Sheeting As Submitted By Jain (Americas) Inc.

Coatings for protection of FRP structures with heavy rain erosion loads

Smartness Labelling and Energy Labelling. George Wilkenfeld, PhD George Wilkenfeld and Associates, Sydney EEDAL 2017, Irvine

Loss Prevention Standard

A MORE EFFECTIVE CLEANING SYSTEM FOR YOUR PERSONAL PROTECTIVE ENSEMBLES

HKIE CPD Training Course (II) 23, 25 June and 7, 9 July 2009

White paper. Construction Product Regulations* by Multimedia Connect. Which cables are concerned by these new regulations?

Transcription:

Fundamentals of Insulation and their effect on buidling sustainability A.S.H.R.A.E. ( Qatar Chapter) Presentation George Georgiou Sekisui Foam International

Company Introduction Sekisui Chemical Co, Japan Large Japanese multinational company Multi-discipline Housing Urban Infrastructure & Environmental Products High Performance Polymers Markets: Housing, Construction, Chemical, Foams, Automotive, Pharmaceutical, Medical Turnover: USD $ 10 billion Employees: 20,000, (23 countries) Pioneered the Physically Crosslinked Polyolefin foam technology World s largest Polyolefin foam manufacturer Sekisui Foam International Manufacturing plants in Japan, USA, Europe, Australia, Thailand Korea, China Manufacturers of Thermobreak Physically Crosslinked Insulation range ISO 9000 - ISO 14000 and extensive environmental initiatives. Video ( Sekisui ) Page 2

Sekisui Chemical Co. Prominent Technology Insulation Products Thermobreak Thermal Insulation Physically Crosslinked Technology Introduced the first ALL-IN-ONE insulation range with factory applied reinforced foil and repositionable acrylic adhesive system Superior Thermal Conductivity lowest for any flexible insulation Superior Vapour Permeability resistance Extensive Fire & Smoke testing to Intrnational Standards Environmentally friendly GREEN STAR rated products Third Party Certification systems

Climate Change & Energy Climate Change and Energy Usage is one of the most significant issues of our time Page 4

Green Building Concept Green buildings are designed to reduce the overall impact of the built environment on human health and the natural environment by: Efficiently using energy, and other resources Protecting occupant health and improving employee productivity Reducing waste, pollution and environmental degradation Carbon Emissions Environmental Friendly Products Indoor Air Quality, Health & safety Energy Efficiency Building Sustainability Page 5

Insulation Central to Energy Efficiecy Global Energy Buldings consume between 25%-40% of total global energy consumption. (OECD Report) Crucial to improve energy efficiency of buildings Building Energy Cooling and heating account between 40%-70% of a building s energy consumption. Energy reduction Insulation Benefits Energy efficient equipment Automation advances Legislation by regulatory authorites. ( Green Building Councils) One of the easiest and most efficient technologies available today to significantly reduce energy costs. Other benefits include personal comfort,sound control, condensation control, fire protection and personnel protection. It has become the focus, and it is central to the Green Building concept. Page 6

Global Energy Reduction initiatives Mandatory Governments schemes to reduce energy by enforcing R values for duct, pipe, wall, roof and floor insulation Page 7 USA & Canada National grid map based on prevailing weather conditions. Each zone requires min R values for insulation such a pipe, duct, wall etc. Thickness of insulation is determined by regulatory authorities to ensure energy reduction and building sustainability levels. Installed thickness v s supplied thickness R values Australia follows the same Zone system with min R values for duct, pipe, wall and roof insulation. Intoduction of Commercial Building Disclosure program through Building Energy Effciency Certificate ( BEEC). Owners must disclose energy efficiency of the building to prospective owners and lessors. Imminent Carbon Tax system (2011) for buildings that use excessive energy.

Global Energy Reduction initiatives New Zealand is also very similar to the system adoprted in Australia ( Zones) Min R values apply Europe 2020 vision to increase energy efficiency in buildings by 20%. EU European Energy Performce of Buildings Directive established in 2002 Minimum energy performance requirements set in respect to AC systems, insulation etc. Energy performance of existing buildings to be upgraded at renovation to meet minimum requirements. Building Energy Certificate program introduced 2010 including AC system efficiency. Page 8

Implications of global trends 1 2 3 4 Insulation will become the focus of energy reductions Insulation properties will come under increasing focus. Includes both peformance and health & safety (eg VOC) Shift from up-front cost to long term performance value to comply with building sustainability directives. Building certification systems means that insulation suppliers MUST be able to verify technical properties and guarantee performance. Page 9

Insulation Changing key selction criteria Thermal efficiency Short term & long term Factors that affect peformance Sustainability Cost Vs. value Long term operating cost Cost to comply with energy reduction initiatives Envornmantall safe products VOC requirements Global Warming potential (EPA) Certification requirements ( LEED) Page 10 Fire & Smoke Standards Health related issues such as bacterial growth Indoor air quality

Insulation types Two broad categories TRADITIONAL TECHNOLOGY Open Cell or fibrous insulation Fibreglass Mineral wool ( Rockwool) NEW TECHNOLOGY Closed Cell Crosslinked Polyolefin (flexible) Elastomeric Rigid cellular (PU, Phenolic)

What is Crosslinking technology? Crosslinking is forcing the linear polyolefin molecules to attain a 3D structure Page 12 Crosslinking can be achieved by Physical means ( irradiation) or Chemical means. Physically Croslinked technology results in : Smaller cell size > lowest thermal conductivity than any other flexible insulation Extremely high vapour permeability resistance Better fire resistance, higher temperature resistance Better compression and tensile strength. More flexible Precise technology > no chemicals used

Critical Insulation Performance factors Thermal Conductivity (k) defines how good a material insulates (W/mK). It is independent of thickness. The lower the k value the better a material insulates It varies according to mean temperature. ASTM C518 most common test method.(fixed consitions) Vapour Permeability is the diffusion of water VAPOUR into the inulation (gas phase). It varies with Temperature and Relative Humidity ASTM E96 most common test method. (Ng/s) (fixed conditons) Water abrosption is the amount of water(liquid) a material can absorb Water in any insulation material decreases its thermal conductivity significantly ( up to 10 times). Very important in cases where condensation occurs some materials like closed cell do not allow spread of water. Page 13

Insulation Fire & Smoke Safety A review of Fire & Smoke Standards Fire & Smoke Standards are formed by safety committees and experts to ensure public safety. There is currently no Standard that requires non combustible materials to be used as duct or pipe insulation BS 476 Parts 6 & 7 Most widely used in ME, Asia and India. Part 6 Combustability ( ignition) measured by i indeces, and FPI total Part 7 Spread of flame : Class 1-4 Class 0 Classification : i1 <6, FPI<12, Class 1 in Part 7 Does not test for smoke density or toxicity! Test is conducted by the accredited facility on the sample submitted by the manufacturer / supplier. No facility inspection or follow up program No verification system to ensure sample origin or manufacturer! Page 14

Insulation Fire & Smoke Safety A review of Fire & Smoke Standards ASTM E84 ( UL 723, NFPA 255) US / CANADA Standard 8m tunnel test Test both Fire spread ( FSI Index) and Smoke development ( SDI) Insulation pass requirements under US Building Code : Flame Spread index MAX : 25 Smoke Developed Index MAX : 50 Test is conducted by the accredited facility on the sample submitted by the manufacturer / supplier. No facility inspection or follow up program No verification system to ensure sample origin or manufacturer! NFPA 90A & 90B Not a Fire standard but insulation requirements referenced to ASTM E84 The new Standard also requires ASTM C411 High Temperature test (120 C) Page 15

Insulation Fire & Smoke Safety A review of Fire & Smoke Standards Smoke Density and Toxicity Standards ISO 5659 with Gas Analysis International Smoke Standard 25 KW, 25KW with flame bruner, 50 Kw exposure Tests for smoke density and Toxiciy ( 6 common combustion gases with low IDLH values, HCL, SO2, HCN, HBr, HF, CO, NOx Pass requirements: Smoke Density : Ds< 200 ( 50 KW/m2 exposure) Emissions levels of above gases have MAX values BS 6853 Test conducted in tube furnace at 600 C, 40 min duration Tests cencentrations of CO, CO2, HF, HCN, HBr, NO2 and SO2 gases Average of each gases used to determine the R index, and comparison to IDLH values (Immediately Dangerous to Life and Health) Page 16

Insulation Fire & Smoke Safety A review of Fire & Smoke Standards AS 1530.3 Building Code of Australia / New Zealand Derived from BS 476 but extended to include smoke, and heat evolved Insulation pass requirements under AS/NZ Building Code : Spread of Flame Index 0 max ( Range 0-10 ) Ignition Index 0 max ( Range 0-10 ) Smoke Developed Index 3 max ( Range 0-10 ) Heat Evolved Index 0 ( Range 0-20 ) Test is conducted by the accredited facility on the sample submitted by the manufacturer / supplier. No facility inspection or follow up program No verification system to ensure sample origin or manufacturer! UL 94 HF Horizontal Fire Test specifically designed for foams. Spread Classification as HF1 HF2- HF3 Under UL follow up inspection program UL collects samples from factory. Regular un-announced inspections and testing. Page 17

Insulation Fire & Smoke Safety Third Party Certification Programs FM Global Global Loss Prevention company with increasing influence Any property insured by FM Global needs to use FM Approved products FM Philisophy is that laboratory scale fire tests are not adequate Utilise large scale fire tests to simulate actual fire situations. The most demanding fire tests. Aproval for insulation is based on FM 4924 Factory audit by FM ( Quality procedures and materials) Witnessing of manufacturing of materials Material sent directly to FM headquerters for testing. Annual audit and inspection. Approved materials carry the FM logo Page 18

Insulation Passive Safety Future and development Third Party Approvals Ensuring Product Conformity Third Party approvals under ISO Guide 67 Certification body must hold accreditation to EN45011 / ISO Guide 65 Dubai Civil Defence approvals for insulation material ( BS 476) now falls under this system. Warrington Exova is such a certification body. Procedure for Civil Defence Approval includes the following : Manfacturing facility audit by approved certification body ( e.g Exova) Quality Systems audit Product witnessing and testing at approved laboratory. Annual audit and verification. ALWAYS ASK FOR TEST CERTIFICATES BY ACCREDITED LABORATORIES NEVER ACCEPT SUPPLIERS CLAIMS AT FACE VALUE Page 19

Thermal Conductivity ( k) Thermal Conductivity varies with mean temperature. The higher the mean temperature the higher the k value Comparisons should be done at the same mean temperature. Thermal conductivity is affected by vapour permeability and water absorprtion If fiberglass absorbs 1-1.5% moisture, its insulation performance is reduced by 36% ( HVAC manual 10.6 McGraw Hill ) Thermal conductivity of a material is defined by its strucure and density and how heat is primarily transferred through the material. Hence differences is fibrous V s cellular material of the same density. Thermal conducivity in fibrous material decreases with increasing density but the opposite is true for cellular materials. Cell size is a determining factor of thermal conductivity in cellular materials, even at the same density. Physically Crosslinked foam ( 25Kg/m3) - 0.032 W/mK @ 23C Chemically Crosslinked foam ( 25 Kg/m3) - 0.038 WmK @ 23 C Smaller cell size means thinner cell wall, therefore primary heat transfer is via Convection.but air is an excellent insulator. Page 20

Water Vapour Permeability What is water vapour? Water exists in the atmoshere in two forms: Liquid Gas Vapour permeability is concerned about the GAS form of water. What affects vapour permeability? Vapour permeability depends of vapour pressure Vapour pressure is determined by : Temperature Relative Humidity Vapour pressure increases both with Temperature and Relative Humidity What is the affect on insulation? Vapour permeability is one of the leading causes of condensation. The condensation is more critical is system where ambient conditions are severe in terms of high temperature and high Relative Humidity(%RH) Page 21

Water Vapour Permeability Condensation mechanism The higher ambient temperature and Relative humidity as compared the lower conditions on the inner interface set up as Vapour Pressure differential. Vapour will permeate through the insulation until it reaches due point conditions. It will CONDENSE at those conditions forming water and saturating the insulation. Vapour permability will seriously affect thermal conductivity. The selection of insulation in areas where high temperature or humidity exist should take vapour permeability into serious consideration Page 22

Implications of Vapor Permeability on thermal performance and sustainability. 1 Vapour Permability is measured by ASTM E96 at controlled laboratory conditions. 2 3 They bare no relation to the ACTUAL ambient conditions that prevail in a region ( eg high temperature in ME) Thermal conductivity will be affected resulting in severe loss of thermal performance and increasing energy costs. (Ref ASHRAE Study- Far East Conference on Air Conditioning in hot climates) 4 Building sustainability and energy savings are compromised! Page 23

A closer look at Vapor Permability of common insulation materials Page 24

A closer look at Vapor Permability at common climatic conditions in ME Measured Vapour permeability data do not reflect observations under actual conditions. Page 25

A closer look at Vapor Permability at common climatic conditions in ME Page 26

A closer look at changes in Thermal Conductivity over time due to Vapour Permability at typical climatic conditions Page 27

Implications of Building Sustainability on insulation selection. 1 Published data on insulation key selection citeria DO NOT reflect actual conditions in severe climates. 2 Key perfoamance criteria such as Thermal conductivity are influnced by many factors and continuously change over time. 3 Desingers of HVAC system will now have to take a more cautious approach taking such changing factors into consideration, and how these affect energy costs. 4 Shift from up-front cost philosophy to long- term operating cost with health & safety also influencing decision making. Page 28

Do You Have Any Questions? We would be happy to help. Page 29