GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL

Similar documents
GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL

GASGUARD SO2 Sulfur Dioxide Sensor OPERATING & INSTALLATION MANUAL

GG-H2S HYDROGEN SULFIDE GAS SENSOR. Installation and Operation Manual

GG-NO2 NITROGEN DIOXIDE GAS SENSOR. Installation and Operation Manual

GG-NH3 AMMONIA GAS SENSOR. Installation and Operation Manual

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL

GASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL

GASGUARD H2S EXP. Hydrogen Sulfide Sensor OPERATING & INSTALLATION MANUAL

GG-CO-EXP CARBON MONOXIDE SENSOR. Installation and Operation Manual

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

GG-NH3-2% AMMONIA GAS SENSOR. Installation and Operation Manual

GG-R REFRIGERANT SENSOR. Installation and Operation Manual

GASGUARD VENT LINE3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

GG-VL-R REFRIGERANT VENT LINE SENSOR. Installation and Operation Manual

GG-LEL2 COMBUSTIBLE GAS SENSOR. Installation and Operation Manual

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

CO2 RESPONDER Portable Carbon Dioxide Detector QUICK REFERENCE GUIDE

MGC Dock User s Manual

OI-2400-DOCK Multi Gas Docking Station. Operation Manual trevision 2.2w

MGC Dock User s Manual

RK Carbon Monoxide Transmitter Operator s Manual

RK Carbon Monoxide Transmitter Operator s Manual

RK Carbon Monoxide Transmitter Operator s Manual

Single Gas Clip and SGC Plus User s Manual Rev 2.1 READ FIRST BEFORE OPERATION WARNING STATEMENTS / AVERTISSEMENT Activating tthe detector for the

RK-05 Carbon Monoxide Transmitter Operator s Manual

CT-7 Series Toxic Gas Transmitter Operator s Manual

RK-02 Multi Point Detector Operator s Manual

RK Hydrogen Sulfide Transmitter Operator s Manual

RK-05 Carbon Monoxide Detector Operator s Manual

Single Gas Clip and SGC Plus User s Manual Rev 2.3

RK CO 2 Transmitter Operator s Manual

RK/ RK Oxygen Detector Operator s Manual

RK-05 Combustible Gas Transmitter Operator s Manual

Tox-COMB/ANA Combustible Gas Transmitter Operator s Manual

RK/ RK Carbon Monoxide Detector Operator s Manual

RK Multi Point Detector Operator s Manual

RK/ RK Oxygen Detector Operator s Manual

RK Combustible Gas Transmitter Operator s Manual

RK Transmitter Technical Notice

RK / RK Methane Detector Operator s Manual

QUICK REFERENCE GUIDE

GasAlertMicro 5. 1, 2, 3, 4, and 5 Gas Detectors. Quick Reference Guide

1228s Multidrop INSTRUCTIONS. Installation and Operation of the AMC-1228s Electrochemical Sensor Module For Use With Multidrop AMC Monitors

RK/ RK Combustible Gas Detector Operator s Manual

User Manual. PolyGard CO LC-1112 V3. Electrochemical analog carbon monoxide transmitters serial no. EC-S 002. August 29, 2006

RK-03 Hydrogen Detector Operator s Manual

RK-CH4-4 Combustible Gas Transmitter Operator s Manual

CMF, CMX & CMA series

NH 3 RESPONDER Portable Ammonia Leak Detector QUICK REFERENCE GUIDE

! "! # Please read these installation and operating instructions completely and carefully before starting.

WATCHMAN Model LBW-WATCHMAN Ammonia Leak Detector

Single Gas Detector. Quick Reference Guide

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

RK / RK CO 2 Detector Operator s Manual

RK-OXY Oxygen Sample-Draw Detector Operator s Manual Part Number: RK Revision: P1 Released: 7/18/02

Operator s Manual. 1, 2, 3, and 4-Gas Detector

Combustible Gas Sample-Draw Detector Operator s Manual

Controllers. Instruction Manual WARNING

Carbon Dioxide Sample-Draw Detector Operator s Manual

Beacon 800 Gas Monitor Operator s Manual

Instruction Manual WARNING

Carbon Monoxide Sample-Draw Detector Operator s Manual

1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR

MaxLite LED MICRO-T PANEL

SEC 2000 Millenium Infrared Gas Detector

Document No

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

GasAlertMicro 5 and GasAlertMicro 5 PID O 2, CO, H 2 S, PH 3, SO 2, Cl 2, NH 3, NO 2, HCN, ClO 2, O 3, VOC, and Combustibles

HIGH VOLTAGE A.C. PROXIMITY DETECTOR HI-PROX

ANALOX 101 D2 PORTABLE OXYGEN MONITOR USER MANUAL

NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL

LV-S-5. Instruction Manual DIRECT CONTACT STRAY VOLTAGE DETECTOR GENERAL DESCRIPTION HOW IT WORKS

Operator s Manual. 1, 2, 3, and 4-Gas Detector

TrueClean ToteCleaner

RKA-03 Sample-Draw Detector Head

NH3 RESPONDER PORTABLE AMMONIA LEAK DETECTOR. Quick Reference Guide

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model 120VC Single Relay (100/25 PPM) (200/35 PPM)

User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access

RKA-06 Sample-Draw Detector

Spa Control System OWNER S MANUAL

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

MODEL: O ELECTROCHEMICAL O2 DETECTOR (Used with ST1400 O2 Sensor) Part Number: MAN Rev. 0

Model C Combustible Gas Transmitter. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

NT DUAL CHANNEL DISPLAY. User Guide

MACURCO INC. CONTROLLERS & CARBON MONOXIDE DETECTORS SS103-3A, SS103-10A SS102H, SS102HC-1 INSTALLATION & OPERATING INSTRUCTIONS

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Remote Relay Module (RRM)

INSTRUCTION MANUAL HS-229G

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

HIH-4010/4020/4021 Series Humidity Sensors

CO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

ST-IAM Sensor Transmitter Integrated Area Monitor. Check / Calibration Procedure* 10 ASH (1)

MODEL QTS-1800 SERIES WALL MOUNT DIGITAL AND ANALOG TRANSMITTER/SENSOR

AT-G-DETECT Gas Sensing System

Installation Guide

Transcription:

GASGUARD Cl 2 Chlorine Sensor OPERATING & INSTALLATION MANUAL

Operating and Installation Manual 2

Table of Contents GasGuard Cl 2 Operating and Instruction Manual General description. 4 Installation.. 4 Locating the sensor. 4 Installation guidelines 5 Wiring.. 6 Operation.. 7 Start-up... 7 Calibration.. 7 Maintenance. 9 Specifications.. 10 Warranty.. 11 Calibration Technologies 866-394-5861 3

Operating and Installation Manual General Description The GasGuard Cl2 sensor is a +24 VDC, three-wire, 4/20 ma sensor for chlorine which utilizes proven electrochemical sensor technology for fast and accurate detection. The 0 5 ppm detection range of the GasGuard Cl2 provides real-time continuous monitoring of chlorine concentrations accurately down to 0.5 ppm without false alarms. The GasGuard Cl2 provides an industry standard linear 4/20 ma output signal compatible with most gas detection systems and PLCs. The output signal is not affected by drastic temperature and moisture variations that occur during daily process cycles. The transmitter circuit board is sealed in potting compound, protecting sensitive electronic components and copper tracing from corrosion. The specially vented chemical-resistant polycarbonate enclosure protects the sensor from accidental damage, weather and direct hose-hits from clean-up crews. Installation Locating the sensor One of the most important considerations when installing GasGuard Cl2 sensors is that they must be easily accessible for calibration and maintenance. For optimum personnel protection (representative concentration reading that an employee would be exposed to), mount the sensor at a height in the breathing zone of the employees. It would typically be about five feet off the ground, which also allows easy access. As a general rule of thumb, try to mount sensors within 30 feet of potential leak sources. Caution: Remove protective cap. The sensor is shipped with a cap installed over the electrochemical cell to preserve cell life. The cell will not detect chlorine gas with this cap installed. Remove cap and discard during installation. 4

Operating and Instruction Manual Installation Guidelines: Remove and discard protective cell cap Always mount the sensor vertically. Must be easily accessible for calibration and maintenance. Mount the sensor close to the potential leak source. For optimum personnel protection, mount sensor in the breathing zone (4 5 above floor). Take air movement and ventilation patterns into account. To prevent electrical interference, keep sensor and wire runs away from mercury vapor lights, variable speed drives, and radio repeaters. Protect sensor from physical damage(forklifts, etc.). If mounting sensor outdoors, consider prevailing wind direction and proximity to the most likely source of leaks. Protect the sensor from sun and rain as much as possible. Never mount the sensor in CA (controlled atmosphere) rooms because normal atmospheric levels of oxygen are required for operation. For highly critical locations more than one sensor should be installed in each room. Mount sensor enclosures through the mounting holes as shown in Figure 1. Use the supplied selftapping screws for mounting on sheet metal surfaces. Figure 1: Mounting dimensions 5

Operating and Installation Manual Wiring Electrical wiring must comply with all applicable codes. Electrical Power: 24 VDC regulated, 350 ma. Output: Linear 4/20 ma output. Monitoring equipment may have a maximum input impedance of 700 ohms. Cable Recommendation: 20/3 shielded cable (General Cable C2525A or equivalent). Length of cable to sensor should be no greater than 1,500 feet. Monitoring: Monitoring equipment must be configured to indicate a fault if the signal is below 1 ma. All signals over 20 ma must be considered high gas concentrations. Alarm setpoints should not be lower than 10% of full-scale range. Wiring Guidelines: Always use three conductor, insulated, stranded, shielded copper cable. Do not pull sensor wiring with AC power cables. This can cause electrical interference. If cable runs cannot be made without a splice, all splice connections should be soldered. Ground the shield at the main control panel. Connect the shield wire in the sensor terminal block labeled SHLD. Use only the existing conduit hole for connections to the sensor. to case ground of monitoring equipment (earth gnd) to ground terminal of power supply to +24V terminal of power supply to signal input of monitoring equipment Figure 2: Wiring diagram 6

Operating and Instruction Manual Operation Start-up Before applying power, make a final check of all wiring for continuity, shorts, grounds, etc. It is usually best to disconnect external alarms and other equipment from the sensor until the initial start-up procedures are completed. After power-up, allow at least 1 hour for the system to stabilize before testing the sensors. Because sensors are normally located at a distance from the main unit, the test time required and accuracy of the response checks will be improved if two people perform the startup procedures and use radio contact. Start-Up Test: 1) One person exposes each sensor to calibration gas or chlorine/water solution. 2) The second person stays at the control unit to determine that each sensor, when exposed to the gas fumes, is connected to the proper input and responds, causing appropriate alarm functions. Calibration The GasGuard Cl2 Sensor comes factory calibrated and should require only minimal adjustments after installation. There are two pots on the preamp that are used for calibration. Note: Never measure sensor output in ma. Always use mvdc or VDC voltmeter settings. Zero Calibration: After the unit is installed and has been powered up for a minimum of 12 hours, the unit can be zero calibrated by the following: Apply Zero Air gas at 0.5 to 1.0 L/min. Adjust the zero pot until the sensor outputs 40 mv from Test [-] to Test [+] (see Figure 3). Span Calibration: Never adjust the span pot without certified calibration gas or chlorine generator. If span adjustment is required, the following procedure will span the unit: Perform zero adjustment before spanning. Apply span gas at 0.5 to 1.0 L/min. Sensor should react to gas within 15 seconds Once the output signal has peaked (or five minutes maximum) adjust the span pot until the correct output is achieved (see Figure 3). Note: Below are a few response characteristics which may be an indication that the gas sensor is at or near the end of its useful life. If any of these are observed, the cell should be replaced: Slow response to / recovery from calibration gas. Failure of the output to reach 50% of the calibration gas value prior to span adjustment. Unable to achieve correct output during span adjustment. 7

Operating and Installation Manual Sensor cable plugs into socket Green LED indicates power Red LED indicates filter activation Span adjustment Zero adjustment Gas cell 40-200 mv mvdc Black Black Red - + 8 Figure 3: Sensor board components and zero/span adjustments

Operating and Instruction Manual Maintenance The GasGuard Cl2 was designed for long life and minimal maintenance. For proper operation it is essential that the test and calibration schedule be adhered to. Calibration Technologies recommends the following maintenance schedule Maintenance Guidelines: The sensor is shipped with a factory calibration. Sensor should be calibrated 6 months from purchase date. Calibrate the detector at least once every 6 months. Calibration should be performed with certified calibration gas. Calibration kits and replacement cylinders are available from Calibration Technologies. Chlorine generators are also available. In highly critical areas, a response test should be performed between calibrations to verify proper sensor response and alarm functions. This can be done with calibration gas or chlorine/water solution. The response test is not required if multiple electrochemical sensors are installed in the same room. All tests and calibrations must be logged. Sensor Life: These electrochemical cells are extremely reliable, but several things can cause the cell chemicals to become depleted including: a period of time exposure to high temperatures continuous, long term exposure to chlorine When the cell becomes depleted, the unit will give no indication of failure other than that the sensor will not respond. For this reason it is absolutely essential that these sensors be calibrated on a regular basis. Typical sensor life is two to three years. When the cell becomes depleted, a replacement cell can be obtained from Calibration Technologies. Simply unplug the cell s ribbon cable from the transmitter, pull the old cell from the spring clip, discard the old cell and replace it with a new one. The sensor can be calibrated after a 12 hour warm-up period. 9

Operating and Installation Manual 10 Specifications Detection Principle: Electrochemical Detection Method: Diffusion Gases: Chlorine (Cl2) Ranges: 0/5 ppm Output Signal: Linear 4/20 ma (max input impedance: 700 Ohms) Power Supply: +24 VDC, 350 ma Response Time: T 50 = less than 60 seconds T 90 = less than 120 seconds Accuracy: +/- 5% of value, but dependent on calibration gas accuracy and time since last calibration Zero Drift: Less than 0.1% of full-scale per month, noncumulative Span Drift: Application dependent, but generally less than 3% per month Linearity: +/- 0.5% of full-scale Repeatability: +/- 1% of full-scale Wiring Connections: 3 conductor, shielded, stranded, 20 AWG cable (General Cable C2525A or equivalent) up to 1500 ft. Enclosure: Injection-molded NEMA 4X polycarbonate gasketed housing. Captive screw in hinged lid. For non-classified areas. Temperature Range: 0 F to +120 F (-18 C to +49 C) Humidity Range: 5% to 100% condensing Dimensions: 7.5 high x 6.5 wide x 3.75 deep Weight: 2 lbs

Limited Warranty & Limitation of Liability Calibration Technologies, Inc. (CTI) warrants this product to be free from defects in material and workmanship under normal use and service for a period of one year (gas sensor covered for six months), beginning on the date of shipment to the buyer. This warranty extends only to the sale of new and unused products to the original buyer. CTI s warranty obligation is limited, at CTI s option, to refund of the purchase price, repair, or replacement of a defective product that is returned to a CTI authorized service center within the warranty period. In no event shall CTI s liability hereunder exceed the purchase price actually paid by the buyer for the Product. This warranty does not include: a) routine replacement of parts due to the normal wear and tear of the product arising from use; b) any product which in CTI s opinion, has been misused, altered, neglected or damaged by accident or abnormal conditions of operation, handling or use; c) any damage or defects attributable to repair of the product by any person other than an authorized dealer or contractor, or the installation of unapproved parts on the product The obligations set forth in this warranty are conditional on: a) proper storage, installation, calibration, use, maintenance and compliance with the product manual instructions and any other applicable recommendations of CTI; b) the buyer promptly notifying CTI of any defect and, if required, promptly making the product available for correction. No goods shall be returned to CTI until receipt by the buyer of shipping instructions from CTI; and c) the right of CTI to require that the buyer provide proof of purchase such as the original invoice, bill of sale or packing slip to establish that the product is within the warranty period. THE BUYER AGREES THAT THIS WARRANTY IS THE BUYER S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. CTI SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, WHETHER ARISING FROM BREACH OF WARRANTY OR BASED ON CONTRACT, TORT OR RELIANCE OR ANY OTHER THEORY. 11

01/2013