PROGRAMMING MANUAL. CM (Micro v. 1.0)

Similar documents
SPARE PARTS LIST TPC A P - TPC VA P

Roll Heated Flatwork Finisher

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB

GH10PA USER MANUAL. Program version 01 MANUAL FOR CONTROLLER FOR CONTROLLING CENTRAL HEATING BOILERS FIRED WITH PELLETS AND OATS

Cylinder Ironers. Operating Supplement. 320 mm Diameter, OPL Insertion width 1664 mm, 2080 mm Refer to Page 5 for Model Identification

INSTALLATION AND MANINTENANCE INSTRUCTIONS

Operating Instructions XWA11V XWA11V. Walk-In Temp / Door /Alarm / Light Module

XWA11V. Walk-In Temp / Door /Alarm / Light Module

USE AND MAINTENANCE. Cm Pelet-set (60-90 kw) TECHNICAL INSTRUCTIONS

MINITOP Refrigerated Self-Service Display underneath

PHASE DMC USER S MANUAL

TECHNICAL INSTRUCTIONS USE AND MAINTENANCE

Operating Instructions XWA11V. XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring

End User Manual ACO 35 MFFI COMBI

1. COMMISSIONING OF THE BOILER en DESCRIPTION FUNCTION BUTTON DESCRIPTION SYMBOL DISPLAY

tcu.z Commercial Programmable Thermostat Installation Instructions

XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring

KFP-CF Series Operation Manual

Installation & Maintenance Manual

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

OMNITOP Refrigerated Display with Ventilated Cooling

EasyTronic III MANUAL SERVICE

Tumble Dryer. Installation/Operation/Maintenance

ZM2 OPERATING AND MAINTENANCE INSTRUCTIONS

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector)

DFZ. In Cab Control Description and Operation

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL

Roth Touchline. German quality since Quick and easy user manual 1/10

Electronic Pellet Burner Controller NPBC-V3-1

AC&R Controller RWR Basic Documentation VR2002 for water to water heat pump units

USE AND MAINTENANCE. Cm Pelet-set TECHNICAL INSTRUCTIONS. (14-35 kw) For boilers: EKO-CK P (EKO-CK 20-40) EKO-CKB P (EKO-CKB 20-40)

Electronic Pellet Burner Controller NPBC-V3M

OPERATION AND MAINTENANCE MANUAL

Monitoring Software for NPBC-V3M-1 User Manual

Instructions of use and maintenance page 2 Electric and refrigerating diagrams page 3 Manual of the thermostat page 4 Spare parts page 6

B-40/B-41 Modulating Temperature Controller

IN NOURISHING SECURITY.

User manual CLIMATIC 200/400 - Controller. Providing indoor climate comfort

SERIES. End User Manual ACO 27 MFFI G.C.N: ACO 32 MFFI G.C.N: ACO 27 RFFI G.C.N: ACO 32 RFFI G.C.

03.03.mmm REV.2 09/01

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

ENGLISH. REMOTE CONTROL / ROOM THERMOSTAT Wireless INSTALLATION SERVICING AND USER MANUAL

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

MODEL T900/950 60LB CAPACITY COMPUTER CONTROL COIN WASHER

Kyung Dong Oil Boiler. Contents. 1. General Warnings Safety Warnings

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

OVEN INDUSTRIES, INC.

ProCon Boiler Controller Commissioning Quick Reference Guide

PHASE NON-COIN USER S MANUAL (S.A.F.E.)

Cimco Series 21. Series 21 - Operator Instruction Manual INDEX. Description. Standard Instructions 2 to 4. Operating Control Panel 5

DFZ. Cabin Control Description and operation

PHASE COIN USER S MANUAL

Digital Thermostat Models: VS30W and VS30B

User Manual. Dryer Controller M720

Quickheat 30 weather compensated boiler control

Each burner shall be equipped with a Micro-Processor Based Burner Management Flame Safeguard and Parallel Positioning Control System.

NR-20DU. Keep this manual near this remote controller for future reference whenever maintenance or service is required.

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

Technology Menu Commercial Laundry

EBC20. Instructions for fitting, installation and operation. Read and save these instructions!

Servicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use

Janfire Pellet Burner Boiler. for single / double burner management (Version 1.1)

USER GUIDE VOGUE MAX SYSTEM

Servicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use

OPERATING INSTRUCTIONS

Digital Thermostat. Models: VS35W and VS35B INSTALLER / USER MANUAL

Ref. 1067/024 Ref. 1067/032A Ref. 1067/052A

Cm Pelet-set (60-90 kw)

Q - Series Boiler. Troubleshooting Manual

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point

INSTRUCTION FOR THE USER THC V E OIL BLU

CentaurStat 7 User Operating Instructions Central Heating Programmable Room ThermoStat

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

Product waste disposal - Protection of the environment:

Line Voltage Non- Programmable Thermostat Installation Instructions & User Guide

SWEBO Bioenergy Manual pellet burner PB20 Rev no. Date Page PBM1: (36) Installation and maintenance instructions

Products documentation (REVISION DATE: 03/10/2011) OMFP6010 (60cm PIROLITIC OVEN)

BG2000S PRE-MIX GAS BURNER

Dryer Controller M720

British Gas 330+ High Efficiency Condensing Boiler. Instructions for Use. To b e l e f t w i t h t h e u s e r. British Gas Service Tel:

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

SWEBO Bioenergy Manual pellet burner PB50 Rev no. Date Page PBM1: (37) Installation and maintenance instructions

Operating principle. Bolero XL (2008)

MACHINE OPERATION. Additional information (including troubleshooting and service) can be found in the individual chapters of the Instructions for use.

Cloudwarm W i- Fi Thermostat Comfort Anywhere Anytime MANUAL

SERVICE MANUAL WASHING WM-WD. Front loader. Platform. EWM1000 EWM1000plus EWM2000evo EWM3000new ENV06 11xx21xx 25xx/35xx

DPC-1 Programmable digital thermostat with communication Versión 2.0. Technical Information. Ref: N

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

Oven Control System Operation - Ver 2.8

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

The Information Contained in this Document is Proprietary and should only be used for Service or Training of Authorized Blodgett Servicers who will

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

User Manual RBS 24. for model CE series ENERGY. Wall mounted instantaneous combi boiler room sealed chamber

(CH 4 ) METHANE GAS DETECTOR AE09/GM, AE09/GM-12, AE09/GM-24

NetworkAIR AFX. Operation and Maintenance AFX65 AFX18

Dixell Installing and Operating Instructions release 7.0

Operating principle. Quinto

OPERATING INSTRUCTIONS. Drying cabinet DC 7774 DC Read the instructions before using the machine.

ADAC. Advanced Deaerator Control

Transcription:

PROGRAMMING MANUAL CM 42-432-632-232-95-255-325 (Micro v..)

CONTENTS: MAIN FEATURES... 3. GENERAL... 3.2 USER INTERFACE... 3.2. KEYS (LOCATED ON THE MEMBRANE)... 3.2.2 SUMMARY OF FUNCTIONS ACTIVATED BY KEY COMBINATIONS... 4 2 FUNCTIONS... 5 2. USAGE OF THE MACHINE... 5 2.. START-UP... 5 2..2 SHUTDOWN PROCEDURE... 5 2.2 CONTROL OF CYLINDER ROTATION... 6 2.3 HEATING... 7 2.3. ELECTRICAL HEATING... 7 2.3.. Heating by a single resistor group... 7 2.3..2 Heating by two resistor groups... 7 2.3.2 GAS HEATING... 7 2.3.3 INDIRECT VAPOUR HEATING... 8 2.3.4 PROGRAMMING THE OPERATING TEMPERATURE... 8 2.4 PROGRAMMING PARAMETERS... 9 2.4. TEMPERATURE MEASUREMENT UNIT... 2.4.2 MAXIMUM SET TEMPERATURE... 2.4.3 OPERATING TEMPERATURE... 2.4.4 REGULATION HYSTERESIS... 2.4.5 STOP TEMPERATURE... 2.4.6 HEATING TYPE... 2.4.7 NUMBER OF RESISTOR GROUPS... 2.5 ALARMS... 2 2.5. INSUFFICIENT AIR FLOW (AL)... 2 2.5.2 SAFETY TABLET (AL2)... 2 2.5.3 THERMAL WARNING FAN (AL4)... 2 2.5.4 SPEED REGULATOR ALARM (AL5)... 3 2.5.5 NO FLAME (AL6)... 3 2.5.6 OVERHEATING OR SENSOR NOT CONNECTED (AL7)... 3 2.6 RESETTING THE PARAMETERS... 4 22/2/27 Page 2 of 4

MAIN FEATURES. GENERAL This microprocessor controls the drying and ironing machines.. A single processor card is capable of controlling models that differ with respect to the cylinder diameter or the heating method (electrical, gas or vapour)..2 USER INTERFACE.2. KEYS (LOCATED ON THE MEMBRANE) Cylinder temperature Speed Increase preset temp. Display preset temp. Decrease preset temp. Increase ironing speed Decrease ironing speed Machine start Button Machine stop button 22/2/27 Page 3 of 4

.2.2 SUMMARY OF FUNCTIONS ACTIVATED BY KEY COMBINATIONS START + STOP + ### programming machine parameters START + SET + ### reset data (-) + (+) reset gas device ### means activating the card by connecting it..22/2/27 Page 4 of 4

2 FUNCTIONS 2. USAGE OF THE MACHINE 2.. START-UP To start the machine, press the START button: START - the indicators light up and show the current temperature and the preset speed (cf. chapter "Control of cylinder rotation") - the indicator VMS lights up (VST is always on) - the fan starts working - the cylinder starts rotating - after 5 seconds, the heating is authorized 2..2 SHUTDOWN PROCEDURE To stop the machine, press the STOP button. STOP The shutdown procedure depends on the current temperature. - if the temperature is automatic shutdown temperature TA (by default 8 C), the machine switches off. - if the temperature is > temperature TA, only the heating is switched off. When the temperature drops below the temperature TA, the whole machine will switch off. During this time interval, the temperature indication and the VMS indicator will blink. The value of TA may be programmed by the manufacturer or during the installation (see "Programming parameters"). 22/2/27 Page 5 of 4

2.2 CONTROL OF CYLINDER ROTATION The cylinder motor is controlled by a speed regulator. You may select 7 different factory preset speeds. ### The speed may be adjusted by the user when the machine is ON by pressing the two arrow keys «up» and «down». The result is shown on the speed display. (Ex.) The current selected value will even be recalled after a power interruption. When the selected speed is not upon starting the machine, the cylinder will rotate at speed while the detected temperature remains below the operating temperature TF (3 C by default); once this temperature is reached, the programmed speed will be activated. When the temperature drops below TF during the operation of the machine, the speed will not be readjusted. When the selected speed is, the cylinder will rotate at speed regardless of the temperature. 22/2/27 Page 6 of 4

2.3 HEATING 2.3. ELECTRICAL HEATING Depending on the model, the electrical heating consists in modifying the current through one or two groups of resistors, controlled by the heating switches. The choice between or 2 resistors is made by setting a parameter (see "Programming parameters"). 2.3.. Heating by a single resistor group When the machine is set up to work with a single resistor group, a special control function is activated (closing and opening the heating relay switch around the set point) in order to be able to achieve and maintain the preset temperature correctly and to avoid the thermal overshoot associated with this kind of heating. It is therefore not an anomaly when you hear the heating relay switch switching frequently when you select this functionality. To show that the heating is activated, the decimal point of the temperature indication lights up. 2.3..2 Heating by two resistor groups When the machine is set up to work with two resistor groups, the temperature regulation switches the first group just as if it were the only control group, while the second resistor group is operated continuously when the temperature is below the set temperature, and switches off when the set temperature is attained. The second group is again activated below a preset hysteresis (see "Programming parameters"). To show that the heating is activated, the decimal point of the temperature indication lights up continuously when both heating groups are on, and blinks when only one group is on. 2.3.2 GAS HEATING When the heating is performed using a gas heater, the machine is fitted with a special electronic device that controls the ignition and working of the heater. The microprocessor controls the gas heater directly when the temperature is lower than the preset temperature. The procedure for resetting the gas heater is given in the alarm section. To show that the heating is activated, the decimal point of the temperature indication lights up. In the section Alarms you will find what to do in case there is no flame. 22/2/27 Page 7 of 4

2.3.3 INDIRECT VAPOUR HEATING When the heating is done using the indirect vapour method, the machine will not perform any heat regulation (and the temperature will be directly proportional to the vapour pressure of the vapour feed of the machine). The microprocessor simply indicates the temperature of the cylinder but will not act on the heating itself. 2.3.4 PROGRAMMING THE OPERATING TEMPERATURE The operating temperature may be set when the machine is on, using the following procedure: ### Press SET The current set value blinks in the display SET ### Use the + and keys to change this value. Hold the key down to change the number rapidly. 3 seconds after releasing the + or key, the displayed value is stored, after which the display again shows the current detected temperature. Programmable range:...tmax C (32...Tmax F) Precision: C The maximum value that the user may set (Tmax) is established by the manufacturer or during the installation using a special procedure. See "Programming parameters". When the selected heating method is electrical, a special system is activated to reduce the overshoot of the heating, such that the preset temperature can be obtained within a range of plus or minus 5 c. This system switches the heating on and off repeatedly as the preset temperature is approached. Therefore, with this type of heating the sound of the relay switching on and off repeatedly is not indicative of a fault condition. 22/2/27 Page 8 of 4

2.4 PROGRAMMING PARAMETERS Some parameters, which normally need not be modified by the user, can be programmed by a special procedure: - Temperature measurement unit 2- Maximum preset temperature: TMax 3- Operating temperature: TF 4- Temperature regulation hysteresis: H 5- Temperature for automatic shut-down: TA 6- Heating type 7- Number of resistor groups installed To enter the parameter setting mode, keep the STOP and START buttons pressed simultaneously and switch the machine on. STOP START The temperature display shows the value of the first parameter to set, while the speed display shows a letter or a number that identifies the parameter. The value blinks to indicate that it may be modified. Use the keys + and to modify the set value. Press SET to confirm the current value and proceed to the next parameter. SET When pressing SET after setting the last parameter, the first parameter is shown again. To exit the parameter setting mode, press STOP or switch the machine off and on. STOP or The setting of the last parameter is only stored if you have confirmed it by pressing SET before leaving the parameter setting mode. 22/2/27 Page 9 of 4

2.4. TEMPERATURE MEASUREMENT UNIT The actual setting is shown on the TEMP display, while U is shown on the VIT display. E.g.: Available values: C / F Default value: C 2.4.2 MAXIMUM SET TEMPERATURE This setting is the maximum value the user may select (Tmax, see "Programming the operating temperature"). The current value is shown on the TEMP display, while M is shown on the VIT display. E.g.: Default value: 8 Parameter range:...8 C (34...356 F) Precision: C 2.4.3 OPERATING TEMPERATURE This setting establishes the operating temperature (TF, see "22. cylinder start-up modes"). The current value is shown on the TEMP display, while r is shown on the VIT display. E.g.: Default value: 3 Parameter range:...8 C (34...356 F) Precision: C 2.4.4 REGULATION HYSTERESIS This setting defines the hysteresis for the temperature regulation. The current value is shown on the TEMP display, while H is shown on the VIT display. E.g.: Default value: 2 22/2/27 Page of 4

Parameter range:...5 C (2...9 F) Precision: C With electrical heating with 2 resistor groups, the hysteresis only affects the second group, while the first is controlled in the usual manner. 2.4.5 STOP TEMPERATURE This setting establishes the maximum stop temperature of the machine, TA (see "Shut-down procedure"). The current value is shown on the TEMP display, while is shown on the VIT display. E.g.: Default value: 8 Parameter range:...8 C (34...356 F) Precision: C 2.4.6 HEATING TYPE This setting establishes whether the heating is electrical (and the same for vapour) or by gas. The current value is shown on the TEMP display, while C is shown on the VIT display. E.g.: Default value: EL Available values: Electrical ("EL. ") / Gas (and vapour) ("GAS") 2.4.7 NUMBER OF RESISTOR GROUPS This setting establishes the number of heating resistor groups installed on the drying and ironing machine. The current value is shown on the TEMP display, while n is shown on the VIT display. E.g.: Default value: 2 Available values: / 2 NOTE: This parameter is only displayed when the electrical heating method has been selected previously. 22/2/27 Page of 4

2.5 ALARMS 2.5. INSUFFICIENT AIR FLOW (AL) This alarm is only activated when the card is set up to work with gas heating. When the pressure valve in the chimney opens for 2 seconds or more, the buzzer is activated for minute while the display shows "AL". + In this case, the heating is switched off. You should now check the direction of rotation of the fans (arrows indicated on the motor), if you have just installed the machine, or check your exhaust system (if the alarm stops when you disconnect the gas exhaust pipe on top of the machine, it is likely that your exhaust is too narrow or blocked). The alarm is not activated during the first seconds after starting the fan, in order to allow the air flow to settle. The alarm is cancelled automatically when the pressure switch returns to its normal position or when the machine is switched off. 2.5.2 SAFETY TABLET (AL2) When the hand protection system is activated (safety tablet), the buzzer is activated for minute and the display shows "AL2". + The machine switches off automatically. Attention: this device is for your safety. Do not override this safety device in order to avoid serious injury to the user! The alarm is cancelled by restarting the machine or switching the machine off and on. 2.5.3 THERMAL WARNING FAN (AL4) When the thermal relay of the fan is activated, the buzzer is activated for minute and the display shows "AL4" : + The fan and the heating are switched off, while the machine remains on. The alarm is automatically cancelled when the machine returns to a normal situation (the thermal relay is closed) or when the machine is switched off. Usually, this alarm is caused by dirt on the fan. 22/2/27 Page 2 of 4

2.5.4 SPEED REGULATOR ALARM (AL5) When the speed regulator alarm is activated, the buzzer is activated for minute and the display shows "AL5" : + The machine switches off automatically. The alarm is cancelled by restarting the machine or switching the machine off and on. This fault condition may be due to an overload of the cylinder motor caused by a thick object inside the machine, or by dirt in the cylinder motor. 2.5.5 NO FLAME (AL6) This alarm is only activated when the card is set up to work with gas heating. When the burner is on or being ignited and the condition no flame occurs, the buzzer is activated for minute and the display shows "AL6". The command for ignition remains active and the machine remains on. To try to re-ignite the burner, press the keys + and simultaneously after the alarm stops. + When the gas device cancels the fault indication, the alarm stops. If this reset fails, the alarm is activated again and one of the following fault conditions occurs: - No gas supply: check that the manual valve of the gas feed is open - The gas pressure is insufficient or the type of gas is incorrect (see the installation section) - The ignition electrode is broken: replace it To cancel the alarm without re-igniting the burner, stop the machine by pressing STOP. 2.5.6 OVERHEATING OR SENSOR NOT CONNECTED (AL7) If the temperature sensor is not connected or broken, or if it detects a temperature above 2 C continuously for 2 seconds, the buzzer is activated for minute and the display shows "AL7". The machine still works and the alarm can be cancelled by switching the machine off. + 22/2/27 Page 3 of 4

2.6 RESETTING THE PARAMETERS If needed, you may reset the parameters to standard values. To activate the standard values, you must start the card up while pressing the keys START and SET simultaneously. The display shows "Pr" to confirm the command and the machine remains in this mode and is not activated. START SET ### To return to the normal working condition, switch the machine off and on again. PARAMETER For electric or steam heating For gas heating temperature measurement unit C C max. set temperature 8 C 8 C Operating temperature 3 C 3 C temperature regulation hysteresis 2 C C stop temperature 8 C 8 C heating type electrical gas number of resistor group (CM-) for -42-432-632-232 2 for 95-255-325 22/2/27 Page 4 of 4

Maquinaria para lavanderia Machinery for laundry Machines pour blanchisserie Pol. Ind. La Quintana C/Energia, nº 2 854 Sant Julià de Vilatorta (Barcelona) SPAIN Tel.: +34 938 887 53 Fax: +34 938 887 663 http://www.domuslaundry.com e-mail: domus@domuslaundry.com export@domuslaundry.com SERVICIO POST-VENTA / AFTER SALE SERVICE Recambios / Spare Parts Tel. +34 938 887 683 Fax: +34 938 887 26 e-mail: parts@domuslaundry.com Servicio Técnico / Technical service Tel. +34 938 887 673 Fax. +34 938 887 26 e-mail: sat@domuslaundry.com