Residential Combustion Application Selection and Cross-Reference Guide

Similar documents
Residential Combustion Application Selection and Cross-Reference Guide

Residential Combustion Application Selection and Cross-Reference Guide

Inventory Management Guide

Inventory Management Guide

Inventory Management Guide

Q4100C Hot Surface Igniter

Hot Surface Ignitor Kits

Homes and Residential Combustion Heating Season New Products and Promotions

24 VAC Intermittent Pilot Gas Ignition Control

50M56U-843 INSTALLER MUST READ DESCRIPTION PRECAUTIONS WARNING CAUTION

Quick Reference Guide. Application. Gas Furnaces Boilers Water Heaters Commercial Cooking. Features

SV9501/SV9502/SV9601/SV9602 SmartValve TM System Control

24 VAC Direct Spark Gas Ignition

Mascot. Gas-Fired Residential and Commercial Wall-Mounted Boiler. Easy Installation, 96% Efficiency, Fully Condensing

INSTALLATION INSTRUCTIONS FOR SERIES 9 INTERMITTENT PILOT IGNITION CONTROL

Single and Multi-Function Aquastat Controllers

L4064B2210 Fan and Limit Controller with 125 F fan on and 100 F fan off stops, 200 F high limit stop and 11 1/2 in. insertion

Product Number L4006A1017 L4006A1132 L4006A1967 L4006A2007 L4006B1007 L4006B1155 L4006B1163 3/4 (19) L4006H1004

Table of Contents. Part Number Index SANDYS INDUSTRIAL GLASS WHEELER A

SV9540; SV9640 SmartValve System Controls

50M56U-843 Universal Single Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

NOW. Fall Heating Specials. Take Advantage of Torrco s Fall Heating Program tailored to YOUR needs! If you don t see it, ask us! Stock Up. & $ave!

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

SV9520H SmartValve System Control Line Voltage Polarity Sense Models

Heating Basics Gas Valve Systems

THERMOSTATS THERMOSTATS HEATING AND COOLING

50M Integrated Single or Two-Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

Operator: Save these instructions for future use!

FG7T (C and L Series)

Y8610U Intermittent Pilot Retrofit Kit

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG:

Proudly assembled in U.S.A

D896 Automatic Vent Damper

Operator: Save these instructions for future use!

CG Section and Base Assembly Series 1 through 12

Operator: Save these instructions for future use!

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH S9V2B040U3-SUB-1-EN. February 2016 S9V2B040U3PSAA TAG:

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

About Carlin. Visit our website, or call us at to learn more about this authentic Made-in-America company.

Operator: Save these instructions for future use!

Interrupted Ignition Series Oil Primary Control

21D83M-843 Integrated Single Stage Furnace Control Replacement Kit INSTALLATION INSTRUCTIONS

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100D4-SUB-1-EN. March 2016 S9V2C100D4PSAA TAG:

CAUTION WARNING. 50T Integrated Furnace Control INSTALLATION INSTRUCTIONS DESCRIPTION PRECAUTIONS

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

TECHNICAL SUPPORT: SERVICE BULLETIN #4 (v ) AB2017 HOT SURFACE IGNITION MODULE OVERVIEW

Model Universal Oil Primary Control

STOP BY AND CHECK US OUT OR GIVE US A CALL AND LET S SEE WHAT WE CAN DO FOR YOU! ORDER ONLINE CALL OUR OFFICE FOR DETAILS

Proudly assembled in U.S.A

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

EG & PEG Series 5 EGH Series 5

50A Integrated Furnace Control

CATALOG: HVAC - Gas Space Unit Heating

All repair parts orders - no minimum charges. Please order with code number. All prices quoted are in U.S. dollars. All prices subject to change

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

CSD-1 COMMERCIAL BOILER CONTROLS

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

BUDERUS. Quality. Versatility. Efficiency. Superior Design. Comfortable. Efficient. Intelligent Heating. Conventional Gas Boilers

96% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

Qualifies for up to $ 1500 Energy Tax Credit! CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ALL NEW, ADVANCED USER FEATURES

Outdoor Reset IQ Option Card, p/n

GAS FURNACES. Communicating Furnace Thermostat. FORM NO. G Supersedes Form No. G RHC-TST550CMMS MID HIGH

Outdoor Reset IQ Option Card, p/n

TECHNICAL SPECIFICATIONS

8+* Bulletin No November 1997

BGH Series Hot Surface Ignition Control

SERIES 19A. mith PRESSURIZED WET BASE

INTRODUCTION THIS MANUAL INCLUDES IMPORTANT SAFETY INFORMATION

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-SOLO-9/04

LAARS MINI-THERM Gas-Fired Residential Hydronic Boilers

MG & SG SERIES BOILERS

INDEX APPLIANCE GAS WATER HEATER CONTROLS 150 ELECTRIC WATER HEATER THERMOSTATS 151 SNAP DISC CONTROLS/LIMITS/SWITCHES 152 GAS DRYER VALVES 153

Smart ways to save energy IntelliCon INSTALLATION MANUAL

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

SERIES 35-63J APPLICATIONS FEATURES SPECIFICATIONS AGENCY CERTIFICATIONS

INSTALLATION INSTRUCTIONS

GAS UNITS KITS AND ACCESSORIES 505,172M 08/06

Rheem Prestige Series Two-Stage Downflow Gas Furnace equipped with the Comfort Control 2. System. RGLE- Series 80% A.F.U.E. Input Rates kbtu

Refer to the Page 23 (inside back cover) for Model Nomenclature. Table of Contents

EGH Series 5. Control Supplement. EGH-105 to EGH-125 Natural gas CSD-1 control system

WE VE MADE OUR 90% FURNACES 100% EASIER. (Our 90% furnaces now make you more efficient, too.)

Operator: Save these instructions for future use!

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Phantom-X 399C/500C. Residential High Efficiency Gas Boilers PHNTM399C, PHNTM500C Submittal Sheet. Wholesaler Job Name Mechanical Contractor

LAARS MINI-THERM Gas-Fired Residential Hydronic Boilers

WARNING FLAIR INTERNATIONAL CORPORATION 600 OLD WILLETS PATH HAUPPAUGE, NEW YORK U.S.A. TEL.: (516) FAX: (516) AMERICAN

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

RHEEM 90%+ GAS FURNACES

95% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS REMOTE CONNECT CAPABLE CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

95% SERIES 2 HEAT ONLY AND COMBINATION GAS WALL MOUNT BOILERS. Bringing. heat and hot water into perfect Balance

AFUE 95% Heating Input 50,000 to 200,000 Btuh

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

TECHNICAL SPECIFICATIONS

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h

Transcription:

Residential Combustion 2011-2012 pplication Selection and Cross-Reference Guide

Support Online Tools Find everything you need to be successful in selling Honeywell products online. Product information, cross-references, demos and more are available at customer.honeywell.com. Table Of Contents PGE Residential Combustion Overview 4 New Products 6 Customer Service Honeywell provides toll-free access to product application, installation and support experts. Technical Support: 1-800-468-1502 Customer Service: 1-888-793-8193 Training Honeywell offers a variety of on-site and web-based training options at customer.honeywell.com. Rewards Make your business count with Honeywell's Contractor PRO Program. Honeywell's Contractor PRO program gives contractors reward points ($) back on Honeywell purchases. Visit www.contractorpro.com for more information. Sales Literature With Honeywell, you ll have access to sales materials that you can use to help grow your business. Visit literature.honeywell.com. Gas Valves 8 SmartValve System Controls 12 Ignition Modules 16 Glowfly Universal Hot Surface Igniter 20 Thermocouples/Thermopiles 22 Universal Electronic Fan Timer 24 Universal Integrated Furnace Control 26 Fan and Limit Controls 30 Oil/Hydronic Controls Oil Primaries 32 Outdoor Reset 36 quastats 38 Heating/Cooling Devices Oil/Hydronic Controls Phone: Residential Technical Support: 1-800-468-1502 Sales Support: 1-800-328-5111 Customer Service: 1-888-793-8193 Residential Zoning: 1-800-828-8367 Online: www.customer.honeywell.com www.forwardthinking.honeywell.com www.literature.honeywell.com Contractor PRO: Phone: 1-800-919-4835 Fax: 1-800-745-4999 Exclusive Technical Support for Contractor PRO members: 1-877-880-3383 www.contractorpro.com heating/cooling devices Relays/Contactors/Transformers 44 2 3

Residential Combustion Universal Products Honeywell Residential Combustion is the industry leader in combustion controls for applications including warm air furnaces, boilers, water heaters, hearth, pool and spa heaters, and service parts. Our products are used on appliances utilizing natural gas, propane, heating oil, and electric fuels and first The only thing we can t replace is you! In the HVC industry today time is money, particularly in the service department, and time lost is money lost. Every time your tech can t complete a job, you could lose money. Every time the tech has to head to the supply house, you could lose money. Every time the tech can t make it to that last call of the day because of extra trips to the supply house, you could lose money. With a parts strategy that includes Honeywell s Universal product portfolio you ll have the right part and you ll make more money nearly every time! The stocking recommendations included in this guide are shown by regional area, U.S. and Canada, and are averaged by product sales. They should be adjusted accordingly to your business size and needs. and foremost assure the safe operation of heating and cooling appliances. Sold primarily through OEM and wholesale channels, our family of products has both the largest breadth and depth of offering in the Product Line Universal Service Part Residential Combustion Universal Products Recommended Inventory Guide U.S. NorthEast U.S. Mid- tlantic U.S. North-NW U.S. South-SE U.S. West Recommended Branch Inventory Canada Eastern Canada Central - West S9200U1000 10 10 10 10 10 6 6 Direct Service Part Replacement (Gas Valves) HVC industry. Ignition Controls S8610U3009 24 24 24 12 12 24 24 S8910U1000 10 10 10 3 6 6 6 Y8610U4001 4 4 4 2 6 Y8610U6006 6 6 6 2 6 2 2 Our offerings include like-for-like replacement parts and a full line-up of universal products that cover Igniters Q3200U1004 20 20 20 20 20 20 20 Q3200U2002 6 6 6 6 6 6 6 Warm ir Limit ST9120U10011 12 12 12 6 6 12 8 almost any application, making Honeywell the only brand of replacement parts you ll ever need. The pages Thermocouple Q3401090 (U.S.) Q3401439 (Canada) 100 100 100 20 20 100 100 in this guide feature our universal products and exciting new offerings for the upcoming heating season! VR82002744 12 12 12 6 6 VR82002322 (Canada) 6 10 VR8200H1236 (Canada) 12 12 VR82002124 VR82002132 VR8304M3509 Gas Valves Hydronic Controls Oil Controls VR8345M4302 12 12 12 6 8 8 12 VR83004516 12 12 12 3 6 4 6 VR8245M2530 3 3 6 2 2 6 8 VR8345H4555 3 3 3 2 2 2 2 VR8345Q4563 2 2 2 N N 1 2 VS8201088 6 6 6 N 3 4 (VS8201054) 6 (VS8201054) L7224U1002 18 18 2 N N 12 8 L7224R1000 18 18 2 N N 12 8 W8735S1000 18 18 2 N N 12 8 W8735S1008 18 18 2 N N 12 8 R7284U1004 10 10 4 N N 12 4 VR8304M4507 VR8305M3506 VR83004508 VR83003500 VR82042076 VR8204M1091 VR82052024 VR8205H1003 VR8304H4503 VR8205Q2555 VR8304Q4511 VR8305Q4500 VS8201054 VS8201336 4 5

New for 2011-12 R7284 Universal Digital Electronic Oil Primary s an industry leader in innovation and new product development Honeywell is always working to provide solutions that make your job easier and more profitable. This heating season we are improving our line of products in the residential combustion market place. The legendary R7284 Universal Digital Electronic Oil Primary offers technicians a field configurable Universal control with intelligent diagnostics that improve system troubleshooting and reduce unnecessary part swapping. The S8610 Universal Intermittent Pilot Ignition Module got a facelift in 2010. The revamped control features direct pilot flame current readout, a simplified timing lock in mechanism and easier to read trouble codes. The S9200 Universal Integrated Furnace Control replaces over 140 furnace boards and includes a complete set of wiring harnesses for universal compatibility and simplified installation. The LED indicators provide system status, performance and diagnostic information. The Honeywell quareset offers homeowners with oil fired hydronic heating systems energy savings in a simple to install offering for the technician. Glowfly the Universal Hot Surface Igniter was the buzz last year with its one-of-a-kind six pack offering and visual cross-reference making it a must-have fter decades of setting the industry standard the time has come for a new Digital Universal Electronic Oil Primary. Its analog predecessor is a living legend and Honeywell has taken it further with a new integrated digital Quick-Fix Indicator for easy diagnostics and programming. The new case design provides an optimum viewing angle for the multi-lingual display along with providing increased wiring space in the junction box. The redundant burner relay and watchdog circuits make this control more reliable than ever before. Simply put, it takes a legend to make one. S8610 Universal Intermittent Pilot Ignition Module The best just got better. The updated version of the S8610U will give improved performance in challenging applications and simplify troubleshooting on service calls. Technicians will be able to get direct flame current readout with a standard micro-ammeter and quickly be able to determine flame strength direct from the board. single LED shows device status along with error codes that have been simplified to allow for faster troubleshooting. It s everything you ve come to expect from the Universal control with a whole lot more. for any service truck. Look for the new, updated packaging for Honeywell's Universal Products. The color packaging includes product specs and easy cross-referencing to make your job easier. Glowfly Introducing the Honeywell Glowfly, It s a whole new species. Replacing over 110 installed silicon carbide models, with a superior universal bracketing design, one of a kind visual cross-reference packaging and it s made from next generation OEM quality Silicon Nitride the Glowfly is the only igniter you will need. Pick up a six pack and light up your igniter business! 6 7

Gas Valves Honeywell has taken the guesswork out of gas valve selection with our complete line of universal gas valves. Contractors appreciate the reliability, ease of installation and time saved by carrying a select few gas valves on their truck. Carrying a few Honeywell Universal gas valves on each truck reduces the amount of inventory needed while still making sure technicians can complete the job in one trip. Honeywell's tried and tested gas valves ensure you will be getting the best product available on the market, every time. VR8345M/VR8345Q/VR8345H/ VR8245M Universal Electronic Ignition Gas Valve Wide-capacity control for almost any IP, HSI or DSI gas-fired appliances Compact fit simplifies field replacement Use with 24 Vac heating appliances, using natural, manufactured or LP gas Use the VR8345Q for a two-stage application, VR8345M for a standard and VR8345H for a slow-opening application Capacities from 20 to 200 (VR8245) cfh or 30 to 415 (VR8345) cfh When selecting a gas valve for your next job, look for these Honeywell features: Universal application Reduced inventory Easy installation and adjustments Compact design VR8300/VR8200 Universal Standing Pilot Gas Valve Combination gas controls for use in 24 Vac, gas-fired, standing pilot appliances with capacities from 20 to 200K Btu/h natural gas, 400 to 200K Btu/h LP gas Includes safety shutoff, manual valve, two automatic operators, pressure regulator and pilot adjustment Universal replacement for virtually all Honeywell and competitive standing pilot valve models VS820 Millivolt Combination Gas Valve Self-powered automatic control Use with 750 mv pilot generator Easy to install and service with all the adjustments and connections accessible from the top of the control 34 to 425 cfh capacity 8 9

Gas Valves Selection Guide Trade Replacements (Double-Check Specifications Before Replacement) Universal Service Part VR83004516 Direct Service Part Replacement Opening Characteristics (standard, step) Inlet/Outlet Size (in.) Specifications Pressure Regulator Setting (psi) VR83004508 Standard 3/4 x 3/4 3.5 in. wc (0.87 kpa) VR83003500 Standard 1/2 x 3/4 3.5 in. wc (0.87 kpa) VR83004516 Standard 3/4 x 3/4 3.5 in. wc (0.87 kpa) Temperature Range (-18 to 79 C) (-18 to 79 C) (-18 to 79 C) Q340 Thermocouple ccessories Includes 3/4" x 1/2" Reducer Bushing Natural to LP Conversion Kit None Two One None One One One Two One 3/4" Straight Flange ccessories Includes 1/2" x 3/8" Reducer Bushing Remote Rod dapter None None None None None None None None None Competitive Replacement Honeywell White-Rodgers Robertshaw VR83004003, VR83004011, VR83004037, VR83004045, VR83004557, VR83004565 VR83003104, VR83003120, VR83003153, VR83003161, VR83003203, VR83003559, VR83003567, VR83003575 VR83004003, VR83004011, VR83004037, VR83004045, VR83004557, VR83004565 36C01-405 700-400, 720-406 (7200ER) 36C03-300, 36C03-400, 36C03-433, 36C03-258 720-404 (7200ER) 720-403, 720-400, 720-402 700-400 VR82042076 Standard 1/2 x 1/2 3.5 in. wc (0.87 kpa) (-18 to 79 C) None None One One One None VR82041201, VR82041219, VR82042001, VR82042175, VR82042803, VR82042225 VR8245M2530 VR8204M1091 Standard 1/2 x 1/2 3.5 in. wc (0.87 kpa) VR82052024 Standard 1/2 x 1/2 3.5 in. wc (0.87 kpa) (-18 to 79 C) None None One None None One One One None VR8204M1075 36E01-204, 36E01-205, 36E01-206, 36E01-305, 36E93-304 722-079 (2000IPERHC) One One None VR82052008 36G22-214, 36J22-214 722-051 (2000DERHC), 720-051 VR8245M2530 Standard 1/2 x 1/2 3.5 in. wc (0.87 kpa) None None One None One None VR8205M1106, VR8205M2310, VR8205M2443, VR8205M2450, VR8205M2476 36E36-304, 36E22-214 720-079 (7200IPER), 720-080 (7200IPER-LP) VR8205H1003 Slow 1/2 x 1/2 3.5 in. wc (0.87 kpa) (-18 to 79 C) None None None None None None VR8305H4013, VR8305H4039, VR8205H2605 VR8345H4555 VR8304H4503 Slow 3/4 x 3/4 3.5 in. wc (0.87 kpa) (-18 to 79 C) None None One None None None VR8204H1006, VR8204H1055 720-070 (7200IPER-S7C), 720-071 (7200IPER-S7C), 720-072 (7200IPER-S7C), 720-073 (7200IPER-LP-S7C) VR8345H4555 Slow 3/4 x 3/4 3.5 in. wc (0.87 kpa) (0 to 79 C) None Two One None None None 36E98-304, 36E24-214, 36E52-214 700-052 VR8304M3509 Standard 1/2 x 3/4 3.5 in. wc (0.87 kpa) None One One None None None VR8345M4302 VR8304M4507 Standard 3/4 x 3/4 3.5 in. wc (0.87 kpa) VR8305M3506 Standard 1/2 x 3/4 3.5 in. wc (0.87 kpa) None Two One None One One None None None VR8304M4002 One None None VR8305M4066, VR8305M4165, VR8305M4231 36G22-214, 36C68-423 720-051 (7200DER) VR8345M4302 Standard 3/4 x 3/4 3.5 in. wc (0.87 kpa) None Two One None None None 36E36-304, 36C68-423, 36H32-423 VR8205Q2555 2-Stage 1/2 x 1/2 1.7 in. wc Low Fire; 3.5 in. wc High Fire None None One None One None VR8205Q2662, VR8205Q2746, VR8205Q2787, VR8205Q2381 36E54-214 VR8345Q4563 VR8304Q4511 2-Stage 3/4 x 3/4 VR8305Q4500 2-Stage 3/4 x 3/4 1.7 in. wc Low Fire; 3.5 in. wc High Fire 1.7 in. wc Low Fire; 3.5 in. wc High Fire None Two One None One One None None None VR8304Q4453 36C76-406, 36C76-420, 36C76-463 None None None VR8305Q4138, VR8305Q4146 36D13-208, 36G54-214 VR8345Q4563 2-Stage 3/4 x 3/4 1.7 in. wc Low Fire; 3.5 in. wc High Fire None Two One None None None 36E96-314, 36D13-405 720-082 (7200IPER2-4) VR82002744 VR82002124 Standard 1/2 x 1/2 3.5 in. wc (0.87 kpa) VR82002132 Standard 1/2 x 1/2 3.5 in. wc (0.87 kpa) (-18 to 79 C) (-18 to 79 C) One None One None None One One One None 720-400 (7200ER), 720-402 (7200ER) VR82002116, VR82002264, VR82002322* One One None 720-400 (7200ER), 720-402 (7200ER) VR82002744 Standard 1/2 x 1/2 3.5 in. wc (0.87 kpa) (-18 to 79 C) None None One One + One Elbow One None VR82002322* VS8201054 Standard 3/4 x 3/4 3.5 in. wc (0.87 kpa) 32 to 175 F (0 to 79 C) None Two None None One None VS8201005, VS8201013, VS8201047, VS8201278, VS8205204, VS8201922 36C03U-300, 36C03U-333, 36C03U-400, 36C03U-433 VS8201088 VS8201336 Standard 3/4 x 3/4 10.0 in. wc (2.49 kpa) 32 to 175 F (0 to 79 C) None Two None None One None VS8201211, VS8201740, VS8201120, VS8201898, VS8201872, VS8201906 VS8201088 Standard 3/4 x 3/4 3.5 in. wc (0.87 kpa) 32 to 175 F (0 to 79 C) None Two One None One Yes VS8201807, VS8202003, VS8201815, VS8201039, VS8202011 Notes: ll piloted valves have a 1/4" compression fitting. ll the VR valves come set for natural gas, but can be converted to LP gas. The VS8201054 is for natural gas. The VS8201336 is for LP gas. ll the VR valves have inlet and outlet pressure taps. The VS820 valves have just an outlet pressure tap. *Canadian Numbers For a complete cross-reference, visit www.customer.honeywell.com 10 11

SmartValve System Controls Honeywell SmartValve combines gas flow control and electronic ignition into a single unit, providing safety and simplified wiring and appliance construction. You ll find Honeywell SmartValves on equipment ranging from furnaces, water heaters, boilers and rooftops to infrared heaters, cooking units and much more. SmartValve Family members cover the full range of opening characteristics (slow, normal, fast) and ignition systems (hot surface, hot surface pilot) Universal kits include natural to LP conversion and 3 4" to 1 2" bushings Universal family increases service efficiency and reduces truck and warehouse inventory * Diagnostic Testers Flame Current Kit #395466 Input Voltage Harness #396085 Q3450C1185/Q3450C2092 SmartValve Pilot Burner The Q3450 SmartValve pilot burners provide pilot flame ignition and sensing for SmartValve intermittent pilot systems. They consist of replaceable igniter-flame rod assembly, bracket assembly, pilot target, ground electrode, orifice assembly, compression fitting and spring clip. The igniter lights the pilot burner. The flame rod proves the pilot flame and the pilot flame lights the main burner Used with SV9500/SV9600 SmartValve System. Replaceable Igniter-Flame Rod ssembly (Q3400). Integral keyed plug provides quick, convenient connection of igniter and sensor to SV9500/ SV9600. Q3450 has front or 20 degree right, left flame pattern. Natural and LP gas orifices available. Variety of target styles available. Variety of mounting brackets available. Q3400 Hot Surface Pilot/Sensor ssembly The Q3400 Igniter-Flame Rod ssembly replaces the original igniter-flame rod assembly in the Q3450 and Q3480 pilot hardware used with the SV9500 and SV9600 SmartValve system. The Q3400 has a unique keyed plug connector that will only fit the SV9500/SV9600 systems. Can be replaced without removing the pilot burner Max temp 250 C Order SKU Q34001024 12 13

SmartValve Control Systems Selection Guide Specifications Specifications Cross-Reference Ignition/pplication HSI Water Heaters Universal Service Part SV95702518 SV95702526 Gas Type Natural LP Opening Characteristics Standard Opening mbient Temperature Range 0 to 150 F (-18 to 66 C) Natural to LP Conversion Kit No Includes 3/4" x 1/2" Reducer Bushings None Includes Extension Harness No OEM Brands.O. Smith.O. Smith Replaces SV95702054, SV95702070, SV95702096 SV95702062, SV95702088, SV95702187 Intermittent HSI Pilot with Combustion ir Control and Limit Monitoring Forced ir Furnace SV9541Q2561 2-Stage Yes None Natural SV9641M4510 Standard Opening Yes Two No ICP, Heil, Tempstar, rcoaire, Comfortmaker, KeepRite ICP, Heil, Tempstar, rcoaire, Comfortmaker, KeepRite, Mestek, Slant/Fin SV9540Q2464, SV9541Q3098 SV9541M2094, SV9540M2229, SV9540M2260, SV9640M4116, SV9640M4124, SV9540M2278, SV9540M2245, SV9640M3126, SV9640M4132 Direct Ignition, General pplication SV9510M2511 SV9520M2536 SV9510K2539 Natural Standard Opening Slow Opening Yes None No Modine Roberts Gordon SV9510M2347, SV9510M2362, SV9410M2902, SV9510M2412, SV9510M2354, SV9410M2910, SV9510M2388, SV9510M2420 SV9420M2331, SV9520M2403, SV9420M2323 SV9510H2228, SV9510K2133, SV9510K2158, SV9510K2141, SV9510K2166 SV9520H8513 Fast-Slow Opening (-18 to 79 C) rmstrong, Concord, irease SV9520H8042, SV9520H8034, SV9520H8067, SV9520H8026 SV9601M4571 Two SV9601M4167, SV9601M3003,SV9601M4225 SV9501M2528 Standard Opening Yes No ICP, Heil, Tempstar, rcoaire, Comfortmaker, KeepRite SV9501M2056, SV9501M2080, SV9501M2718, SV9501M2726, SV9501M2031, SV9501M2049, SV9501M2239, SV9501M2700, SV9501M2734, SV9501M2742, SV9501M2064 SV9501M8129 Fast-Fast None SV9501M8103 Intermittent HSI Pilot, General pplication SV9502H2522 SV9602P4816 Natural Slow Opening (-18 to 79 C) Yes Laars, Utica, rmstrong, Concord, ireease Burnham, ICP, Heil, Tempstar, rcoaire, Comfortmaker, KeepRite SV9501H3415, SV9501H2417, SV9501H2409, SV9502H1706, SV9502H2704, SV9501H3423, SV9501H2425 SV9501P2004, SV9601P4107, SV9501P2053, SV9502P2101, SV9602P4105 SV9602P4824 SV9602P4832 Step Opening None Two Yes Burnham Burnham SV9501P2087, SV9601P4172, SV9502P2127, SV9602P4121 SV9501P2020, SV9501P2046, SV9601P4149, SV9601P4164, SV9502P2119, SV9502P2135, SV9602P4113, SV9602P4139 SV9602P4840 SV9601P4115 For a complete cross-reference, visit www.customer.honeywell.com 14 15

Ignition Modules Honeywell ignition controls have a long history of safe and reliable performance. Grow your business while reducing inventory with Universal ignition modules. full lineup of Universal replacement electronic control is available for nearly all intermittent or hot surface ignition applications from gas-fired furnaces to boilers. S8610U Universal Intermittent Pilot Ignition Module Flame voltage auto-adjusts for improved operation Usable in both single-rod or dual-rod systems Field-selectable pre-purge and ignition trial timings Simple, diagnostic LED helps direct service effort Direct pilot flame current readout with standard micro-ammeter Plug in vent damper connection simplifies installation Replaces over 400 Honeywell and competitive models When selecting ignition modules for your next job, look for these Honeywell features: Universal application with field adjustable timings Flexibility for use in single-rod or dual-rod systems Quality, reliability and safety of field proven controls Simplified installation S8910U Universal Hot Surface Ignition Module Easy field replacement for most hot surface ignition modules Single-rod or dual-rod systems LED diagnostics and field-adjustable ignition timings Natural or LP gas ll retrofit accessories included Replaces over 650 Honeywell and competitive products Y8610U Universal IP Retrofit Ignition System Kit Use with 24 Vac gas-fired atmospheric furnaces, boiler and heating appliances Convert standing pilot appliance to electronic ignition Natural or LP gas 16 17

Ignition Modules Selection Guide pplications Timings Features and Functions Cross-Reference Universal Service Part S8910U1000 Ignition System Line Volt Hot Surface Ignition Flame Sensor Ignition Sequence (Note 1) 1 or 2 Rods P Ignition Trials To Lockout (Note 1) 1 or 3 Field Selectable Ignition Trial Time 4 sec. or 7 sec. Field Selectable Between Trial Time 96 sec., 3 Trial Mode Only Pre-Purge Flame Failure Response Time 32 sec. 1.5 sec. Type of Gas Nat or LP Ignition Source Switched Line Voltage Typical Ignition Hardware Norton 201, Norton 271, Hot Surface Elements, Q354 Flame Rod Includes Honeywell White-Rodgers Robertshaw S89C1004, S89C1012, S89C1046, S89C1087, S89C1103, S89D1002, S89G1005, S89G1013, S89G1021, S89G1047, S89H1003, S89H1011, S89H1029, S89J1008, S890C1007, S890D1006, S890G1003, S890G1011, S890G1029, S890G1037, S890H1002, S890H1010, S890H1028 50E47-1 thru 50E47-79, 50E47-101 thru 50E47-179, 50E47-201 thru 50E47-279, 50E47-301 thru 50E47-379, 50F47-1 thru 50F47-79, 50F47-101 thru 50F47-179, 50F47-201 thru 50F47-279, 50F47-301 thru 50F47-379 HS780-17NL-104, HS780-17NL-108, HS780-17NL-304, HS780-17NL-308, HS780-17NR-104, HS780-17NR-306, HS780-17NR-308, HS780-34NL-108, HS780-34NL-304, HS780-34NL-306, HS780-34NL-308, HS780-34NL-312, HS780-34NR-104, HS780-34NR-306, HS780-34NR-308, HS780-34NR-312, HS780-34PL-308, Johnson Controls S8610U3009 Intermittent Pilot 1 or 2 Rods C C 15 sec. or 90 sec. Field Selectable 5 Minute Delay fter Failed Trial for Ignition 0 sec. or 30 sec. Field Selectable 2.0 sec. max. Nat or LP Internal Q345, Q3451, Q3452 Integral Damper Connector S86 Series,S90 Series, S8600 Series, S8610 Series, S8620 Series, S8660 Series, S8670 Series, S8680 Series 50D49-350, 50D49-360, 50D49-361, 50D50-843, 50D49-401 780-002, 780-003, 780-715, 780-735, 780-736, 780-737, 780-845, SP715, SP715, SP735D, SP735L, USI715U, SP735, SP750 Series CS42, 43, 44, 45, 46, 48, 49, G60, G65, G67, G770 Series Y8610U6006 Conversion for Standing Pilot Single Rod C C 15 sec. or 90 sec. Field Selectable 5 Minute Delay fter Failed Trial for Ignition 0 sec. 2.0 sec. max. Nat or LP Internal dapter for Pilot Burner Included Y8610U3003 Y8610U4001 Conversion for Standing Pilot Single Rod C C 15 sec. or 90 sec. Field Selectable 5 Minute Delay fter Failed Trial for Ignition 0 sec. 2.0 sec. max. Nat or LP Internal dapter for Pilot Burner Included Notes: 1. Ignition Sequence C P Continuous retry fter trial for ignition, pilot gas shuts off for five minutes, then another trial for pilot ignition takes place. The number of trials for ignition and trial time is determined by the selection tab. If a selection tab is not installed, the module will operate at four seconds trial time and one ignition trial. For a complete cross-reference, visit www.customer.honeywell.com 18 19

Universal Hot Surface Igniter Replacing a hot surface igniter can be a tricky job. Furnace designs and specifications change. ppliance designs can be tight and difficult to maneuver in. Then there s the need to carry a variety of replacement parts to match the range of hot surface igniter configurations out there. Now, those challenges have one reliable solution: Glowfly from Honeywell. Q3200U2002 Six Pack Q3200U1004 Single Pack 20 When selecting an igniter for your next job, look for these Honeywell features: Next-generation OEM silicon nitride quality for any installation Custom designed bracketing for universal installation The strongest warranty in the industry void being caught unprepared with the unique truck-ready six-pack Graphic instructions provide for quick and accurate bracket selection and installation Match and mount simplicity. Simply remove the old igniter and compare it with the diagrams on Glowfly s unique packaging guide to determine the correct mounting bracket for the job. Six brackets. 110+ possibilities. Every Glowfly comes fully equipped with six custom mounting brackets that are optimized to replace over 110 igniter applications from nearly every furnace manufacturer without modification. Igniter Bracket Replacement Cross Reference a Manufacturer OEM # Q3200U Bracket b merican Road Equip. 201W rco ir 1096048 1380680 D rmstrong ir 38322B001 LH33ZS001 Carrier/ Bryant/ Payne LH33ZS001 LH33ZS002 LH33ZS002 LH33ZS003 LH33ZS003 LH33ZS004 B or E c Claire Bros. C-238 C242 Coleman 1474-051 1474-052 Comfort Maker 1096048 D Detroit Radiant 201D DMO Ind. 20834 Dornback Furnace 271W Ducane 20015201 B Enero Tech 10399 Evcon 1474-051 1474-052 Evcon Coleman 025-32625-000 B B1401009 D Goodman B1401018 C B1401018S D HB Smith 50018 Heil 1096048 D Hupp Industries 09050 Intercity 1009604 1096048 D Majestic 75-92-104 75-92-105 Metzger 201N 201W Manufacturer OEM # Q3200U Bracket b Modine 5H76032 C Mor-Flo 3200618 511-330-193 B 105141000 Nordyne 632-0770 632-0880 201 271 B 201D 201K 201L Norton/St Gobain 201N 201R 201W 271N 271NM D 271P 271W Raypak 600915 B Rheem 62-22441-01 Roberts Gordon 90434300 B 90436600 41-402 41-403 B 41-404 B 41-405 Robertshaw 41-407 B 41-408 41-409 B 41-410 41-412 D 41-418 C 1380654 Snyder General 1380672 1380680 B Superior Fireplace 94851 a Table data is correct to the best of Honeywell s knowledge as of this publication s date. However, some appliances may have igniter applications that are beyond the capabilities of this kit. b For igniters that require bracket, use the template to determine the tab to be removed. c For Carrier sealed combustion furnaces, you must use bracket E and retain the existing orange gasket for use with bracket E. For a complete cross-reference, visit www.customer.honeywell.com Manufacturer OEM # Q3200U Bracket b Tempstar 1096048 D 340039P01 B138196P01 B B144676P01 B144676P02 B Trane B340039P01 IGN23 IGN26 B IGN30 B IGN34 Viessman 9302-094 Wayne Home Equip. 62821-001 62821-002 511-330-139 Weil McLain 511-330-190 511-330-193 B White LB 120-07549 767-301 767-303 F 767-306 767-311 767-350 767-353 F 767-354 767-357 F White-Rodgers 767-361 767-364 767-366 767-370 B 767-371 767-372 767-373 D 767-376 B 767-377 767-382 B Williamson 9050 025-27766-000 York 025-27774-000 025-29043-000 025-29050-000 21

Thermocouples/Thermopiles Contractors depend on Honeywell for easy installation and reliable performance. Built for long service life, the Honeywell Q313, Q340 and Q390 will work for nearly all pilot generated millivolt applications. When selecting a thermocouple or thermopile for your next job, look for these Honeywell features: Variety of lead lengths Easy installation Many accessories included Durability Q313 Replacement Thermopile Variety of lead lengths Push-in clip, split nut and adapter assembly included Male nut connector for Pilotstat included Generates 750 mv in a millivolt heating system Thermocouple and Thermopile Selection Guide Lead Length (in.) US Super Tradeline Canada Tradeline Thermocouples Cross-Reference White-Rodgers Robertshaw Husky Johnson Controls 18 Q3401066 Q3401405 Q3901095 H06E-518, HO6E-18 K16BT-18 K19T-18 24 Q3401074 Q3401413 Q3901046 H06E-524, HO6E-24 1970-24, 1980-24 K16BT-24 K19T-24 30 Q3401082 Q3401421 Q3901053 H06E-530, HO6E-30 1970-30 K16BT-30 K19T-30 36 Q3401090 Q3401439 Q3901061 H06E-536, HO6E-36 1970-36, 1980-36 K16BT-36 K19T-36 48 Q3401108 Q3401447 Q3901103 H06E-548, HO6E-48 K16BT-48 K19T-48 Q340 Universal Thermocouple Variety of lead lengths Push-in clip, split nut and adapter assembly included Male nut connector for Pilotstat included Generates 30 mv in standing pilot systems The Q340 is a premium thermocouple with the long life and durability that your customers demand; built with a maximum amount of copel, the Q340 will provide long-lasting service that reduces callbacks and keeps your customers happy Model Q313 Item Lead Length (in.) Thermopiles Connection Tradeline/Super Tradeline Q3131022 35 Nut & Spade Terminal Tradeline Q3131139 35 Clip & Spade Terminal Super Tradeline Push-In Clip Q3131170 35 Clip & Spade Terminal Super Tradeline PG9 dapter (393948) Q3131188 35 Nut & Spade Terminal Super Tradeline Push-In Clip, 1/2" ttaching Nut Q3131055 47 Nut & Spade Terminal Tradeline 1/2" ttaching Nut Q3131105 75 Nut & Spade Terminal Tradeline 1/2" ttaching Nut For a complete cross-reference, visit www.customer.honeywell.com Notes Q390 Universal Thermocouple Variety of lead lengths Push-in clip, split nut and adapter assembly included Male nut connector for Pilotstat included Generates 30 mv in standing pilot systems For situations where a utility grade thermocouple is the best solution, the Q390 is the right choice 22 23

Universal Electronic Fan Timer Replaces all others. The new universal platform that will not only integrate control of all combustion blower and circulating an operations in a gas warm air appliance but also replace most ST9120, ST9141 and ST9160 fan timer boards. Save room on your truck or on your shelves with a supply of ST9120U1011 timers and know you re covered. When selecting fan timers for your next job, look for these Honeywell features: Universal application Easy installation Quality construction for long service life ST9120U1011 Replaces 44 existing Honeywell controls to reduce inventory Integrates control of all combustion blower and circulating fan operations in a gas warm-air appliance Replaceable fuse DIP switch selectable heat and cool delay on and off times Diagnostic LED EC and HUM convenience terminal connections and continuous low speed indoor air circulation are provided ST9120U REPLCES OVER 44 EXISTING MODELS ST91011006 ST9120C3018 ST9120G4038 ST9160B1001 ST91011014 ST9120C4008 ST9120U1003 ST9160B1019 ST91011022 ST9120C4016 ST91411002 ST9160B1027 ST91202004 ST9120C4040 ST91411028 ST9160B1035 ST9120B1005 ST9120C4057 ST9141B1001 ST9160B1043 ST9120C1012 ST9120C5005 ST91501003 ST9160B1050 ST9120C1020 ST9120C5013 ST9150B2000 ST9160B1068 ST9120C2002 ST9120D3009 ST9150B2018 ST9160B1076 ST9120C2010 ST9120G2024 ST9150B2026 ST9160B1084 ST9120C2028 ST9120G2032 ST9150B2034 ST9160C1000 ST9120C3000 ST9120G4004 ST91601002 ST9160C1018 Universal Electronic Fan Timer OEM Replacement Guide Recommended Dip Switch Setting Replaced Control Model Number Original OEM ppliance 1 2 3 4 5 ST91011006 Rheem off off off off off ST91011014 Rheem off off off off off ST91011022 Trade off off off off off ST91201006 rmstrong off off off off off ST91202004 rmstrong on off on off off ST9120B1005 Ducane off on off off off ST9120C1012 Snyder General on off off off off ST9120C1020 Nordyne on off off off off ST9120C2002 York off off off off off ST9120C2010 Ducane off off off off off ST9120C2028 rmstrong off off off off on ST9120C3000 ICP off off on on off ST9120C3018 Bard on off off off on ST9120C4008 ICP off off on on off ST9120C4016 ICP off off on on off ST9120C4040 ICP off off on on off ST9120C4057 ICP off off on on off ST9120C5005 ICP off off on off off ST9120C5013 ICP off off on off off ST9120D3009 Goodman off off on off on ST9120G2008 ICP on off off on off ST9120G2016 ICP off off off on off ST9120G2024 Skymark off on off on off ST9120G2032 Skymark off on off off on ST9120G4004 ICP off off on on off ST9120G4012 ICP off off on on off ST9120G4038 Trade off off on on off ST9120U1003 Trade off off on off off ST91411002 Consolidated Industries off off on off on ST9160B1035 off off off off off ST9160B1068 rmstrong on off off off on ST9160B1076 Ducane off off off off off ST9160B1084 ICP off off on off on ST9120U Factory Default Setting off off off off off For a complete cross-reference, visit www.customer.honeywell.com 24 25

Universal Integrated Furnace Control The Honeywell Hot Surface Ignition Universal Integrated Furnace Control offers universal compatibility and remote monitoring and diagnostics. ble to replace a large number of furnace controls in singlestage heating and cooling appliances. Honeywell UIFCs are the only controls you need for residential natural or liquid propane fueled furnaces. When selecting furnace controls for your next job, look for these Honeywell features: Replaces over 140 furnace controls Complete set of wiring harnesses for universal compatibility, simplified installation and field-adjustable timings LED indicators provide system status, performance and diagnostic information EnviraCOM communications enabled HSI Universal Integrated Furnace Control Complete set of wiring harnesses for universal compatibility and simplified installation allowing for direct replacement of competitive boards LED indicators provide system status, performance and diagnostic information EnviraCOM -enabled for easy setup of local or remote monitoring and diagnostic systems Ready for remote services, whether you re replacing old controls or installing new equipment like the VisionPRO IQ, Telephone ccess Module or EnviraZONE Engineered for reliability and long-term performance mana 10207701, 10207702, 10207703, 10207710 Goodman 1809913, B1809913, B18099-13 ICM ICM280 ICP 1010806, 1380-686, 1380-699 Lennox 1214201 S9200U1000 replaces these Integrated Furnace Controls 624557, 6245570, 624557-0, 624564, 6245640, 624591, 624591, 624591-, 624591-B, 624591-C, 624591-D, 624628, 624628-0, Nordyne 6246310, 624631-0, 624631, 624631-, 624631-B, 710128, 902378, 902696, 903106, CR903106 Rheem/Robertshaw 62-24268-01, 62-24268-02, 62-24268-03, 695-200 Texas Instruments 6DT-1, 6DT-2, 61F3, 41F-5 D330927P01, D330930P01, D330934P01, D340035P01, D340354P01, D340774P01, D341235P01, 5050-571, 5055-571, 5050-473, Trane 5050-474, 5050-405, 5050-406, 5050-471 United Technologies 1012-925, 1012-925B, 1012-925C, 1012-955, 1012955, 1012-83-9651B, 1012933D, 1012-933D, 1012-83-9336HSC1, 1012-83-9337 5055-843, 5050-110, 5050-111, 5050-112, 5050-113, 5050-142, 5050-143, 5050-205, 5050-206, 5050-207, 5050-209, 5050-230, 5050-241, 5050-285, 5050-286, 5050-288, 5050-295, 5050-296, 5050-405, 5050-406, 5050-408, 5050-438, White-Rodgers 5050-471, 5050-473, 5050-474, 5050-571, 5055-120, 5055-143, 5055-241, 5055-285, 5055-286, 5055-288, 5055-438, 5055-474, 5055-571, 50T35730, 50T35-730, 50T35743, 50T35-743, D330927P01, D330930P01, D330934P01, D340035P01, D340354P01, D340774P01, D341235P01 03100662000, 031-00662-000, 031-00662-700, 031-01140-000, 031-01140-001, 031011140002, 031-01140-002, 031-01140-701, 031-01140-702, 031-01234-000, 031-01235-000, 031-01234-700, 031-01235-700, 031-01250-000, 031-01266-000, 31-01267-00, 031-01267-000, 031-01267-001, 031-01267-001, 031-01284-000, 031-01933-000, 031-01972-000, 031-01973-000, 031-02166-000, York 031-09166-000, 031-09167-000, 331-01933-000, 331-01972-200, 331-09167-000, 43101972100, 431-01972-100, P03101267001, P031-01267-001, PTH031011400-00, CR33101972200, CR03101973000, CR5055843, G951DB1401, G951DB1401C, G951DB-1401C, G951DB1402, G951DB-1402, G951EB-1403, 031-00662, 031-01266-000 For a complete cross-reference, visit www.customer.honeywell.com 26 27

Universal Integrated Furnace Control Selection Guide Goodman 1 ICM ICP Lennox Nordyne Rheem/Robertshaw Trane TI UTEC SKU 1809913, B1809913, B18099-13 Harness Field Settings Recommendation Safety Time Settings SW1 SW2 SW3 SW4 SW1 SW2 Main Harness E & Inducer/HSI Harness F On Off 60/90/120/180 60/90/120/180 Off On ICM280 Main Harness E & Inducer/HSI Harness F Check Control Field Settings Check Control Safety Timings 1010806 1380-686 1380-699 Inducer/HSI Harness On Off 60/90/120/180 1214201 Inducer/HSI Harness On Off On Off Off Off 624557, 6245570, 624557-0 624564, 6245640 624591 624591, 624591-624591-B 624591-C 624591-D 624628, 624628-0 6246310, 624631-0 624631, 624631-624631-B 710128 902378 902696 903106, CR903106 62-24268-01 62-24268-02 62-24268-03 Main Harness D & Inducer/HSI Harness B On Off 60/90/120/180 60/90/120/180 On Off Main Harness D & Inducer/HSI Harness C On Off 60/90/120/180 60/90/120/180 On On 695-200 D330927P01 On Off 60/90/120/180 60/90/120/180 Off Off D330930P01 D330934P01 D340035P01 Off Off Off On D340354P01 D340774P01 D341235P01 On Off On Off Inducer/HSI Harness 5050-571 On Off 60/90/120/180 60/90/120/180 Off Off 5055-571 2 Off Off On Off 5050-473 5050-474 5050-405 Off Off 60/90/120/180 60/90/120/180 Off On 5050-406 5050-471 41F-5 Main Harness E & Inducer/HSI Harness F On Off 60/90/120/180 60/90/120/180 Off On 6DT-1 6DT-2 Inducer/HSI Harness On Off 60/90/120/180 60/90/120/180 Off On 61F3 1012-925 1012-925B Main Harness D & Inducer/HSI Harness C On Off 60/90/120/180 60/90/120/180 On On 1012-925C 1012-955, 1012955 Main Harness D & Inducer/HSI Harness B On Off 60/90/120/180 60/90/120/180 On Off 1012-83-9651B Inducer/HSI Harness On Off 60/90/120/180 60/90/120/180 Off On 1012933D, 1012-933D 1012-83-9336HSC1 1012-83-9337 Main Harness E & Inducer/HSI Harness F On Off 60/90/120/180 60/90/120/180 Off On 1 Wiring harness G should be used if the control being replaced has a 2-pin inducer/igniter connector instead of a 4-pin inducer/igniter connector. Off Off Off On mana 1 White-Rodgers 1 York SKU Harness Field Settings Recommendation Safety Time Settings SW1 SW2 SW3 SW4 SW1 SW2 10207701 10207702 10207703 10207710 Inducer/HSI Harness On Off On Off Off On 5050-110 5050-111 On Off Off On 5050-112 60/90/120/180 60/90/120/180 5050-113 5050-142 Inducer/HSI Harness On Off Off Off 5050-143 On Check Settings Off On 5050-205 5050-206 On Off On Off Off On 5050-207 5050-209 5050-230 Inducer/HSI Harness On Off On On Off On 5055-241 5050-241 On Off 60/90/120/180 Off On 5050-285 Off Off On Off Off Off 5050-286 On Off 60/90/120/180 60/90/120/180 Off On 5050-288 Inducer/HSI Harness On Off On Off Off On 5050-295 On Off On Off Off On 5050-296 On Off Off On 60/90/120/180 60/90/120/180 5050-438 Check Settings On Off On 50T35730, 50T35-730 Main Harness E & Inducer/HSI 50T35743, 50T35-743 Harness F On Off 60/90/120/180 60/90/120/180 Off On 5055-120 Inducer/HSI Harness Off Off On Off Off Off 5055-143 On 30/60 Off Off Inducer/HSI Harness G 60/90/120/180 60/90/120/180 5055-285 On Off Off Off 5055-286 On Off Off On 5055-288 On Off 60/90/120/180 60/90/120/180 Off Off 5055-438 Inducer/HSI Harness Check Settings Off Off Off 5055-474 Off Off On Off Off Off 5055-843 Check Settings Check Settings 60/90/120/180 60/90/120/180 Off Off 03100662000, 031-00662-000 031-00662-700 031-01140-000 031-01140-001 031011140002, 031-01140-002 031-01140-701 031-01140-702 031.01234.000 031-01234-700 031-01235-000 031-01235-700 031-01250-000 031-01266-000 0310126700 031-01267-000 031-01267-001 031-01267-001 031-01284-000 3101933000, 031-01933-000 031-01972-000 031-01973-000 Inducer/HSI Harness On Off 60/90/120/180 60/90/120/180 Off On 031-02166-000 031-09166-000 031-09167-000 33101933000, 331-01933-000 331-09167-000 331-01972-200 43101972100, 431-01972-100 G951DB1401 G951DB1401C, G951DB- 1401C G951DB1402, G951DB-1402 G951EB-1403 P03101267001, P031-01267- 001 PTH031011400-00 CR33101972200 CR03101973000 CR5055843 031-00662 Use with only 120 VC ppliances For a complete cross-reference, visit www.customer.honeywell.com 28 29

Fan and Limit Controls Fan and Limits Selection Guide Honeywell fan and limits combines high temperature limit with circulating blower control. s an industry standard for many years, these controls have a large and varied installed base. You ll find Honeywell fan and limits on a wide range of furnace equipment. Our universal family increases service efficiency and reduces truck and warehouse inventory. Model OS# Region L4064B2228 US/ Canada Element Insertion Length (in.) 5 Replaces L4064B1600, L4064B3440, L4064B3010, L4064B1683, L4064B2228, L4064B2640, L4064B2889, L4064B2947, L4064B3374, L4064B3432, L4064B2897, L4064B3598, L4064B3515, L4064E2502, L4064E2585, L4064E2528, L4064F1098, L40642501, L40641339, L40641503 High Limit Stop ( F) Fan-on Stop ( F) Fan-off Stop ( F) Manual Fan Button Manual Reset 160 to 200 110 to 125 85 to 100 Yes No Switching ction Fan: SPST N.O. (make on rise), Limit: SPST N.C. (break on rise) Key features for the family of universal fan and limits: Family members cover the full range of insertion 5", 8", 11-1/2" L4064W1080 US/ Canada 5 L4064W1072, L4064W1163, L4064W1197, L4064W1056, L4064W1064, L4064W1296, L4064Y1565 200 120 90 Yes No Fan: SPST N.O. (make on rise), Limit: SPST N.C. (break on rise) djustment tool and cross-reference allow for field adjustment to factory settings Universal kit accessories reduce inventory L4064 High Limit and Fan Controller Used in all types of forced-air heating systems Three wiring terminal options available for easy installation vailable in a variety of fan and high-limit setting ranges Controls adapt to many competitive mounting holes in replacement applications Push-in receptacles for stripped wire L4064 models for timed fan on Special high temperature limit models available Suitable for line voltage, low voltage or millivoltage control applications L4064 L4064B2236 US/ Canada L4064R1142 Canada 8 L4064W1098 L4064B2210 US/ Canada US/ Canada 8 8 11.5 L4064B3457, L4064B1618, L4064B1691, L4064B2608, L4064B2905, L4064B2962, L4064B2772, L4064B3572, L4064B3051, L4064B3085, L4064B3499, L4064B3481, L4064B3390, L4064E2452, L4064E2544, L40642279, L40642998, L40642030, L40641735, L40641347, L40641511, L40642774 L4064R1019, L4064R1118, L4064R1126 L4064W1007, L4064W1171, L4064W1130, L4064W1221, L4064W1205, L4064W1288, L4064T1707, L4064T1715, L4064T1780, L4064T2093, L4064T2440, L4064W1015, L4064Y1573 L40641321, L40641453, L40642758, L40643046, L4064B3580, L4064B3465, L4064B1592, L4064B1725, L4064B1931, L4064B2210, L4064B2723, L4064B2863, L4064B2954, L4064B3036, L4064B3044, L4064B3077, L4064B2756, L4064B3069, L4064E2551 170 to 250 120 to 140 90 to 104 Yes No 180 to 250 125 100 Yes Yes 150 to 220 100 to 185 90 to 120 Yes No 170 to 250 122 to 130 90 to 104 Yes No Fan: SPST N.O. (make on rise), Limit: SPST N.C. (break on rise) Fan: SPST N.O. (make on rise), Limit: SPST N.C. (break on rise) Fan: SPST N.O. (make on rise), Limit: SPST N.C. (break on rise) Fan: SPST N.O. (make on rise), Limit: SPST N.C. (break on rise) L6064 High-Limit and Two-Speed Fan Controller Provides two-speed fan control Continuous low-speed and high-speed on-call for heat L4064R1134 Canada 11.5 L4064W1106 US/ Canada 11.5 L4064R1100, L4064R1068, L4064R1035, L4064R1027 L4064T1046, L4064T2457, L4064W1213, L4064W1254, L4064Y1540 170 to 250 125 100 Yes Yes 200 to 210 125 to 130 100 Yes No L60641052 Canada 5 L60641094, L6064E1020 180 to 200 105 to 125 90 to 100 No No Fan: SPST N.O. (make on rise), Limit: SPST N.C. (break on rise) Fan: SPST N.O. (make on rise), Limit: SPST N.C. (break on rise) Fan: SPDT, Limit: SPST N.C. (break on rise) Same overall size and mounting as L4064 Same specifications as L4064 L6064 L60641045 Canada 8 L60641086 200 125 to 130 100 No No L60641037 Canada 11.5 L60641003, L60641078, L60641151 200 125 to 165 85 to 100 No No Fan: SPDT, Limit: SPST N.C. (break on rise) Fan: SPDT, Limit: SPST N.C. (break on rise) * Some models limit, Fan On and Fan Off need to be adjusted. For a complete cross-reference, visit www.customer.honeywell.com 30 31

Oil Primaries Honeywell has set the standard for oil-fired furnaces, boilers and water heaters when it comes to oil primary controls. In addition to delivering dependability and high quality products, Honeywell has gone one step further to create an easy-to-use oil primary control designed to simplify installation and enhance maintenance. Our latest innovation will redefine that standard as the next generation of controls proves, it takes a legend to make one. R7284U1004 Universal Digital Electronic Oil Primary single part number for nearly all applications helps reduce inventory cost 16 character two line tri-lingual display provides simple programming and diagnostics No additional tool to purchase to take advantage of all control features Monitors igniter and cad cell and alerts technician what component caused ignition failure Error history and baseline readings provide system performance trends When selecting an oil primary for your next job, look for these Honeywell features: Universal application with field adjustable timings Integrated display allows for setup without using and external tool dvanced diagnostics that direct the technician to the likely cause of ignition failure Legendary performance and reliability R8184 Protectorelay Oil Burner Control Industry-standard intermittent ignition control Solid-state, flame-sensing circuit 45-second timing, safety switch Mounts on standard 4" x 4" junction box External button to manually reset safety switch after lockout Oil/Hydronic Controls R8182 Combination Protectorelay and Hydronic Heating Controllers Immersion-type quastat controller and oil burner primary control Provides high limit and low limit/circulator control Use in intermittent ignition applications Circulator zone control with ZC and ZR terminals on R8182D, E, H, J W8735S3000 EnviraCOM larm Module Works with any alarm generating EnviraCOM enabled control Local LED alarm present and communication active indication Simple low-voltage, 5-wire installation 32 33

Oil Primaries Selection Guide Oil Primaries Specifications Cross-Reference Ignition Type Universal Service Part Lockout Time (sec.) Valve On Delay (sec.) Blower Off Delay (min.) larm Contacts Manual Trip Lever w/ LED Indicator Honeywell Beckett Carlin White-Rodgers 15 0/15 0/2/4/6 Yes* Yes R7184U1004, R7184P1031, R7184P1049, R7184P1056, R7184P1064, R7184P1072 7505P125M 50200-02S, 602000-02S, 6020002S015120, 6020002S030015, 6020002S030030, 6020002S030120, 6020002S030300, 6020002S030010 Interrupted R7284U1004 15 15 0.25 0/15 0/2/4/6 30 No 45 0/15 0/2/4/6 Yes* No 15 Yes* R71841026, R71841075, R71841000 75050000 40200-02S 669-640,669-670 R7184B1024, R7184B1032, R7184B1016 R7184P1080, R7184P1098 R7184U1012 7505B1500 7505P1515 R71841018, R71841034 42230-02S R7184U1020 R71841042 R8184G1294, R8184G1302, R8184G4066, R8184G4074, R8184G4033, R8184G4090, R8184G1427, R8184G4058 669-440, 669-445, 669-470, 669-540 75050000 668-601, 668-670 Oil/Hydronic Controls Intermittent R7284U1004 30 45 Yes R8184G1393, R8184G1302, R8184G4074, R8184G4033 668-501 R8184G1286, R8184G1427, R8184G1458, R8184G4009, R8184G4025, R8184G4082, R8184G4108 48245-S 668-401, 668-415, 668-430, 668-515 Yes* 668-430 R8184M1051 45 R8184M1002 668-441, 668-451, 668-454 (1) Includes 40 V transformers and heat/cool thermostat connections for warm-air furnace applications. *larm accessory module required. EnviraCOM larm Module W8735S3000 Direct Service Part R8182 Combination quastat and Oil Primary Mounting Features and Functions Differential Temperature ( F) High Limit Low Limit/ Circulator Includes Upgraded Cross-Reference Honeywell R8182D1079 Vertical 10 fixed 10 to 25 Heat-Conductive Compound R8182E1118 R8182D1111 Horizontal 10 fixed 10 to 25 Heat-Conductive Compound R8182D1129 R8182H1070 J Box 10 fixed 10 to 25 Heat-Conductive Compound R8182J1042 J Box 15 fixed Heat-Conductive Compound R8182J1059 Product Number CD Cells (1) Lead Length (in.) C5541463 130367 60 Wire Termination 2 Flag 1/4" QC Mounting Bracket Type R C5541794 130367 60 Stripped Type R Notes: *120320 replacement CD cell 7.5 M minimum sensitivity at 2' candles. *130367 high-sensitivity CD cell 12 M minimum sensitivity at 2' candles. CD Cell Selector Guide Includes, B, E, J and P Mounting Brackets and Fuel Line daptor E Mounting Bracket and Fuel Line daptor Tradeline Value Super Tradeline Tradeline Replaces White-Rodgers Westwood C5541307, C5541315, C5541398, C5541133, C5541174, C5541372, C554C1570, C5541216, C5541927, C5541794 C5541307, C5541927 956-154 TMK-60 956-11 956-154 TMK-60 Stack Switches Model Number Ignition Type Replaces R1161055 Intermittent R1161063 R1171047 Interrupted For a complete cross-reference, visit www.customer.honeywell.com 34 35

Outdoor Reset The quareset improves comfort and efficiency inside because it knows the weather outside. Our new product is designed to help homeowners save on energy costs by operating their boiler at more efficient settings based on the actual outdoor temperature while providing the necessary heat to maintain a comfortable indoor temperature. Integrating easily into any Honeywell outdoor reset ready electronic quastat, this product provides easy installation and up to 15 percent energy savings for the homeowner. L7224R1000 Honeywell quareset Outdoor Reset System Designed to improve boiler efficiency by automatically resetting boiler water temperature based on outdoor temperature Upsell opportunity for contractors during a oil-fired service call Boost mode ensures homeowner comfort needs quickly met when control in reset Meets 2012 DOE mandate to include advanced control on boilers Compatible with EnviraCOM larm Module (W8735S3000) W8735S1000 Honeywell quareset Outdoor Reset Kit Designed to improve boiler efficiency by automatically resetting boiler water temperature based on outdoor temperature Upsell opportunity for contractors during a new boiler installation when an Outdoor Reset Ready quastat is present Simple installation with three wire connection to the quastat Compatitble with any L7224 or L7248 Outdoor Reset Ready quastat Oil/Hydronic Controls W8735S1008 Honeywell quareset Domestic Hot Water Kit Required for domestic hot water override with some Honeywell s quareset installations* Compatible with Honeywell quareset system and kit Ensures domestic hot water needs are met when combining quareset with an indirect DHW tank. Easy three-wire installation to quareset module * Kit required to enable domestic hot water override functionality with Indirect DHW tank when the Zr terminal on the quastat is not used or available for DHW demand. See instructions or visit customer.honeywell.com for complete details. *Honeywell Inc. 1979 Study; Control Systems Providing Energy Savings with single and multi-zone Hydronic Heating. 15% is the average energy savings and can only be achieved when installing an outdoor reset model, domestic hot water priority is off and the unit is installed as directed. 36 37

quastats The boiler industry standard, Honeywell quastats have a proven track record, wide OEM new equipment usage and a large installed base. Our electronic quastat family builds on this reputation while adding performance-enhancing features. Honeywell service parts have you covered, offering universal compatibility and improved service call efficiency while keeping both distributor and contractor satisfaction in mind. When selecting an quastat for your next job, look for these Honeywell features: Broad range and flexibility covers a variety of applications and needs Universal versions allow multiple mounting and configuration capability Universal versions reduce inventory and assure truck availability Electronic versions include communications as a standard feature, allowing add-on efficiency, troubleshooting and monitoring capability EnviraCOM communications enabled SINGLE-FUNCTION MULTI-FUNCTION L7224 Universal Oil Electronic quastat Diagnostic updates through easy-to-read LED displays +/- 2 F accuracy and faster response times djustable high- and low-limit differential Outdoor reset functionality available with W8735S1000 Provides multizone control Thermowell horizontal or vertical and flush mounting EnviraCOM communications enabled dd alarm contacts with W8735S3000 L8124/L8148 Triple quastat Relay Oil and gas versions High-limit or high-and-low-limit versions Mounts directly on boiler horizontally or vertically Provides multizone control Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems The L8148 includes a transformer to provide power for the low-voltage control circuit Gas versions include a transformer to provide power for the low voltage circuit L6006/L4006 quastat Controller Totally enclosed Micro Switch snap-acting switches operate on temperature rise to setpoint Visible control point scale and external adjustment screw permit easy setting Horizontal or vertical insertion of sensing element Direct or well immersion of the sensing element SPST and SPDT switching action L6008/L4008 quastat Controller Visible control point scale and external adjustment screw permit easy setting Horizontal or vertical mounting of the remote element into boiler, tank or other container Fast-responding remote temperature sensor SPDT or SPST switching action Oil/Hydronic Controls 38 39

Single-Function quastat Selection Guide Sensor and Thermowell Features and Functions Features and Functions Notes Cross-Reference Product Number 1 Switch Configuration Thermowell Included Thermowell Spud Size 14 NPT (in.) Capillary Length (in.) 2 Manual Reset Operating Temperature Range ( F) L40061009 Yes 1/2 1-1/2 100 to 240 L40061017 Yes 1/2 1-1/2 100 to 240 L40061132 Yes 3/4 3 100 to 240 160 L40061678 3 100 to 240 L40061959 3 40 to 180 L40061967 Yes 1/2 1-1/2 100 to 240 3 L40062007 3 100 to 240 L40062148 3 100 to 200 L4006E1042 Yes 130 to 270 3 240 L4006E1067 3 Yes 130 to 270 L4006E1091 SPST - N.C. (break on rise) 3 Yes 130 to 270 L4006E1125 3 Yes 100 to 200 L4006H1004 1-1/2 100 to 240 3 240 L4006G1022 3 100 to 200 L40081015 66 100 to 240 3 L40081130 120 130 to 270 L40081189 66 130 to 270 L4008E1156 66 Yes 130 to 270 250 L4008E1305 66 Yes 100 to 240 240 L4008E1313 66 Yes 100 to 200 3 L4008E1347 66 Yes 40 to 180 3 L4006B1007 SPST - N.O. Yes 1/2 1-1/2 100 to 240 L4006B1155 (make on rise) 3 100 to 240 L60061004 Yes 1/2 100 to 240 L60061012 Yes 1/2 1-1/2 100 to 240 L60061145 3 100 to 240 240 L60061244 3 100 to 240 L6006C1018 SPDT 65 to 200 L60081093 66-30 to 70 3 L60081192 66 100 to 240 240 L60081242 66 100 to 200 3 Factory Stop ( F) Differential Temperature ( F) 5 Fixed Electrical Ratings 4 Notes OEM or Trade Product Number 5 to 30 L4080B, L4080D Families, L40061058, L40061827, L40062015 5 Fixed L40062023 5 to 30 2 Fixed B 5 to 30 5 to 30 5 to 30 Canada Only L4006E1091, L4006E1109, L4006E1117, L4006E1125, L4006E1133 D D Bracket for Strap-On Mounting 7 H Canada Only 5 to 30 5 to 30 5 to 30 L4008E1040, L4008E1248, L4008E1321 L4008E1271, L4008E1313 Meets Certain State Specific Boiler Inspector Requirements 5 Fixed 5 to 30 L4006B1189, L4008B1163 5 5 to 30 L60061160, L60061269, L60061301, L60061327, L60061335 5 to 30 Horizontal Mount Only L40061004 5 to 30 5 to 30 Includes Surface Mount Using 1/4" NPT Female Threads or Surface Mount Through Base of Case L6006C1034, L6006C1059 5 to 30 L60081010 5 to 30 5 to 30 Oil/Hydronic Controls ll mounting is universal horizontal or vertical mounting unless noted. ll Tradeline quastats include heat-conductive compound. 1 Product Numbering 400X=SPST, 600X=SPDT X006=Thermowell Sense, X008=Remote Sense Make on Rise B Break on Rise D Break on Rise w/o Cover E Make on Rise w/manual Reset G Two SPDT H Make on Rise w/strap-on Mount 40 2 Capillary Length If less then 3" then insulation depth of thermowell 3 ll manual reset models comply with the CSD-1 requirement for Manual Reset. Devices with maximum Range of 200 F, 190 F 180 F are designed to meet local code requirements regarding maximum setpoints. Units having scale ranges above 240 F do not comply with SME Section IV for boilers, use 240 Maximum range quastats. 4 Electrical Ratings Millivolt: 0.25 @ 0.25 to 12 Vdc; FL: 8 @ 120 Vac/5.1 @ 240 Vac LR: 48 @ 120 Vac/30.6 @ 240 Vac D Millivolt: 0.25 @ 0.25 to 12 Vdc; FL: 1.3 @ 240 Vac/8 @ 120 Vac; LR: 48 @ 120 Vac/30.6 @ 240 Vac B FL: 2.6 @ 120 Vac/1.3 @ 240 Vac; LR: 15.6 @ 120 Vac/7.8 @ 240 Vac H FL: 8 @ 120 Vac/1.3 @ 240 Vac; LR: 48 @ 120 Vac/30.6 @ 240 Vac For a complete cross-reference, visit www.customer.honeywell.com 41

Multi-Function quastat Selection Guide Fuel Low Limit High Limit Features and Functions Cross-Reference Product Number Gas Oil Operating Range, Low Limit ( F) Differential Temperature, Low Limit ( F) Operating Range, High Limit ( F) Differential Temperature, High Limit ( F) Factory Stop ( F) Switching ction nticipator Setting Mounting Notes OEM Part Number L60811010 110 to 220 130 to 240 10 fixed SPDT H L60811069 L60811036 110 to 220 10-25 130 to 240 10 fixed SPDT H L40811023, L40811148, L40811155, L40811171, L40811189, L40811197 L8148E1265 180 to 240 15 fixed L8124E1016 110 to 220 10 to 25 130 to 240 10 fixed L8148J1009 120 to 240 8 fixed L7224U1002 110 to 220 10 to 25 130 to 240 5 to 20 adj. 240 2 SPST: High Limit & Circulator 2 SPST: High & Low Limit 2 SPST: High Limit & Circulator 3 SPST: High and Low Limit, Circulator 0.2 V 0.2 0.2 V/H 0.1 V/H/F Universal Oil, Digital Display and Settings, Used with Oil Burner pplications, EnviraCOM Communications L8148E1158, L8148E1182, L8148E1216, L8148E1065 ll L8124 or C, L8148 or C, L7224 or C, L7248 or C, L8151 Oil/Hydronic Controls L81241007 110 to 220 10 to 25 130 to 240 10 fixed 0.2 V L81241015, L81241015, L81241049, L81241106, L81241114, L81241130, L81241155, L81241015 L8124C1003 110 to 220 10 to 25 130 to 240 10 fixed 2 SPST: High & Low Limit 0.2 H L8124C1094, L8124C1102 L8124G1020 110 to 220 10 to 25 130 to 240 10 fixed 2 SPST: High & Low Limit 0.2 V L8124G1004, L8124G1012 L8124L1011 110 to 220 10 to 25 130 to 240 10 fixed 2 SPST: High & Low Limit 0.2 H L8124L1003, L8124L1029, L8124G1038, L8124G1046 L81481017 140 to 240 8 fixed 240 2 SPST: High Limit & Circulator 0.2 H L81481165, L81481157, L81481124, L81481090, L81481082, L81481009 * Replacement Sensors for the 7224U. OS Number Length 50001464-001 12" 50001464-004 36" 50001464-005 48" For a complete cross-reference, visit www.customer.honeywell.com 42 43

Relays/Contactors/Transformers Honeywell offers a complete range of relays, contactors and transformers for all your residential and commercial HVC applications. ll Honeywell products are designed to exceed safety and industry life cycle standards. In order to meet these criteria, a statistically significant sample of Honeywell products are tested to failure and to our stringent qualification requirements. This testing Transformers Honeywell offers NEM standard DC20-1992 and general purpose transformers. These transformers are available with single or multiple input voltages and with foot, conduit and plate mounting options. Transformers with circuit breakers that can be manually reset by pressing a button are also available. Honeywell also designs transformers for specific environmental requirements and with specialized termination options. methodology enables Honeywell to verify that these products will exceed industry standards. Relays Honeywell s switching relays are available in multiple configurations for various applications. For whatever you need general purpose relays or electric heat relays Honeywell has you covered. General Purpose and Heavy-Duty Switching Relays R4222, R8222, R4228 and R8228 for use in refrigeration and air-conditioning equipment, appliances and vending machines Time Delay Relay ST82 combines the R8222 or R8228 relay for use in compressor-run air conditioning and heat pump systems; this product features an electronic timer that delays blower shut off after the compressor has shut off. Fully Enclosed Line and Low-Voltage Fan Relays R4225 and R8225 for control of line voltage fan motors and auxiliary circuits. Input Voltage/Coil Voltage Switching Product Number Full Load mp Rating Relays Frequency Dimensions (in.) H x W X D Electrical Connections (main) Special Features 24 Vac DPST N.O. R8228D1018 5.5 DPDT (1 P & 1 P Duty) R8222V1003 1 7/8 x 2 5/32 x 2 3/8 DPDT Pilot Duty R8222N1011 Pilot duty 24 Vac DPDT R8222D1014 DPDT ST82D1004 2 7/32 x 2 1/16 x 2 9/16 80 sec shut off delay Q SPDT R8222B1067 12 DPDT Pilot Duty R4222N1002 120 Vac DPDT R4222D1013 1 7/8 x 2 5/32 x 2 3/8 SPDT R4222B1082 208/240 Vac DPDT R4222D1021 SPDT R82251017 24 Vac DPST N.O. R8225D1003 14 B 2 11/16 x 2 1/2 x 3 7/16 L 120 Vac SPDT, 1 N.O., 1 N.C. R42251008 24 Vac SPDT R8228B1012 18 1 7/8 x 2 5/32 x 2 3/8 Q Electric Heat Relays R82291005 24 Vac DPST 7 B 2 3/16 x 2 3/32 x 2 1/4 CHS Extra mounting R82291021 hardware Electric Furnace Sequencer 24 Vac R8330D1039 7.2 B 3 1/16 x 4 13/16 x 2 11/32 T Electric Heat Contactor 24 Vac DPST R82461038 30 2 3/16 x 2 1/4 x 3 5/16 Q, S Frequency: 60 Hz/50 Hz; B 60 Hz, C 50 Hz SPST: Single Pole Single Throw pprovals: UL, CS DPST: Double Pole Single Throw Temp Rating: -20 F to +150 F; 115 F max for R8225 DPDT Double Pole Double Throw Connectors: CHS Combination Head Screw; L Leadwires; Q Quick connect; T Terminals SPDT: Single Pole Double Throw Electrical Ratings (V) Electrical Ratings (Input Voltage) Product Number NEM Rated Mounting Main Connections Transformers Secondary Connections Frequency Dimensions (in.) H x W X D Special Features 19 V 120 Vac T201123 F L 2 x 2 1/4 x 1 7/8 T72D1006 P S 3 7/32 x 2 7/32 x (1 1/16 into x 2 in. above plate) T72D1089 F S 3 7/32 x 2 7/32 x 3 1/16 120 Vac T72D1188 P L 3 7/32 x 2 7/32 x 2 15/16 40 V T72D1683 M S T72D1956 Yes M L vailable only in Canada 3 7/32 x 2 7/32 x 3 1/16 T72D1691 M S 208/240 Vac T72D1733 M S vailable only in Canada 48 V 277 Vac T871189 F L L Energy limiting overload protection 480 Vac T871155 F L 2 15/16 x 2 7/32 x 2 1/4 Energy limiting overload protection 50 V 120/208/ Built-in protection; Primary winding T871106 M S 240 Vac burnout 120 Vac T120B1028 F L 1 11/16 x 3 3/16 x 1 3/4 Metal end bells 20 V 120/208/ 240 Vac T1201004 M S 2 7/8 x 1 7/8 x 2 15/16 Metal end bells T1401000 M S 3 3/16 x 2 3/8 x 3 1/8 Metal end bells 120 Vac T140B1206 F L 1 11/16 x 3 1/2 x 1 3/4 Plastic end caps 40 V 120/208/ T1401018 M S B 3 3/16 x 2 3/8 x 3 1/8 Metal end bells 240 Vac T140B1214 F L 1 11/16 x 3 1/2 x 1 3/4 Plastic end caps 50 V 75 V Frequency: Mounting; Connections: pproval 120/208/ 240 Vac 208/277/ 480 Vac T1501007 M S 1 11/16 x 3 3/16 x 1 3/4 Metal end bells T150F1022 M L 3 3/16 x 2 3/16 x 3 5/8 L No T150F1030 M L 3 3/16 x 2 3/16 x 3 5/8 Button for resetting circuit breaker & metal end bells Button for resetting circuit breaker & metal end bells 277 Vac T150B1252 F L, Q L, Q 1 11/16 x 3 1/2 x 1 3/4 Plastic end caps T1751008 M S 3 3/16 x 2 3/8 x 3 5/8 Metal end bells 120/208/ 240 Vac Button for resetting circuit breaker & T175F1023 M L 3 3/16 x 2 3/16 x 3 15/16 B metal end bells 208/277/ 480 Vac T175F1031 M L L 3 3/16 x 2 3/16 x 3 15/16 120 Vac T881005 F L 208/240 Vac T881021 F L 480 Vac T881047 F L 2 15/16 x 2 3/16 x 3 5/16 60 Hz/50 Hz; B 60 Hz; C Conduit ; F Foot; P Plate; M Foot, Conduit, Plate (F models do not come with plate options) L Leadwires (9 in. to 13 in.); Q Quick Connects; S Screw Terminals UL, CS Button for resetting circuit breaker & metal end bells Internally fused secondary for overload protection Heating/Cooling Devices 44 45

Relays/Contactors/Transformers Contactors Fan Centers Honeywell offers definite-purpose contactors for heating, cooling and refrigeration applications. vailable in 1, 2, 3 and 4 pole configurations. Multiple input voltage range from 24/120/208/240 configurations. vailable in 25, 30, 40, 50, 60, 75 and 90 mp configurations. Meet RI 780 and UL/CS/CUR standards. Quick connects for coil termination. Hex screw and quick connects on units up to 30 ; lugs on units rated at 40 and above. Poles Contact Ratings (FL @ 240, 277, 480, 600 Vac) Input Voltage/ Coil Voltage Product Number Dimensions (in.) H x W x D Economy Contactors Main Connections Coil Connections Contact Ratings (Resistive @ 240, 277, 480, 600 Vac) Cutler Hammer Cross Reference Information 1 with shunt 30 24 Vac DP10301000 2 7/32 x 2 1/2 x 3 5/16 48 C25CNB130T 45EG10J 91320, 17311 24 Vac DP20301003 3 1/4 x 3 5/8 x 3 7/8 CHS 48 C25BNB230T 45EG2OJ 61354, 17321 30 120 Vac DP2030B1002 2 7/32 x 3 5/16 x 2 5/32 40 C25BNB230 45EG2OF 61346, 17322 2 208/240 Vac DP2030C1001 2 7/32 x 2 1/2 x 3 5/16 Q 40 C25BNB230B 45EG2OG 61347, 17323 24 Vac DP20401002 C25BNB240T 45GG20J 61355, 17421 40 120 Vac DP2040B1001 2 3/8 x 3 5/16 x 2 LC 50 C25BNB240 45GG20F 61356, 17422 208/240 Vac DP2040C1000 C25BNB240B 45GG20G 61357, 17423 PowerPRO Contactors RI 780/790 Rated 25 DP10255005 2 7/32 x 2 1/2 x 3 5/16 CHS 30 Not vailable 45DG10J 61315 1 with shunt 30 24 Vac DP10305013 2 7/32 x 2 1/2 x 3 5/16 CHS 48 Not vailable 45EG10J 13101, 61320, 61720 40 DP10405004 2 23/64 x 2 1/2 x 3 5/16 LC 50 Not vailable 45GG10J 61330 20 24 Vac DP20205021 2 7/32 x 2 1/2 x 3 5/16 30 Not vailable 45CG20J 61310 120 Vac DP2020B5038 2 7/32 x 2 1/2 x 3 5/16 30 Not vailable 45CG20F 61336, 14122 24 Vac DP20305004 3 1/4 x 2 5/8 x 3 3/4 C25DND230T 45EG2OJ 61345, 13104, 91321, 60510 24 Vac DP20305012 3 1/4 x 2 5/8 x 3 3/4 60510 120 Vac DP2030B5003 2 7/32 x 3 5/16 x 2 5/32 C25DND230 45EG2OF 61346, 13105, 120 Vac DP2030B5011 2 5/16 x 3 5/16 x 2 5/32 CHS Q Not vailable 60031 2 30 208/240 Vac DP2030C5002 48 C25DND230B 45EG2OG 61347, 13106, 60512, 60032 208/240 Vac DP2030C5010 2 7/32 x 2 1/2 x 3 5/16 Not vailable Not vailable 6,051,291,323 277 Vac DP2030D5001 Not vailable Not vailable 60153, 24 Vac DP20405003 C25DNF240T 45GG20J 13107 91421, 61355, 61755, 60525, 40 120 Vac DP2040B5002 2 23/64 x 3 3/16 x 1 15/16 LC 50 C25DNF240 45GG20F 13108, 91422, 61356, 61756, 208/240 Vac DP2040C5001 C25DNF240B 45GG20G 13109, 91423, 61357, 61757, 60527, 14423 24 Vac DP30305003 C25DND330T 42BF35J 61430, 13113, 60515, 13007, 91331 30 120 Vac DP3030B5002 CHS 40 C25DND330 42BF35F 61431, 13114, 91332 208/240 Vac DP3030C5001 C25DND330B 42BF35G 61432, 13115, 91333, 60517, 13009 24 Vac DP30405002 C25DNF340T 42CF35J 60530, 14423, 61445, 13013 91431 40 120 Vac DP3040B5001 50 C25DNF340 42CF35F 61446 208/240 Vac DP3040C5000 C25DNF340B 42CF35G 60532, 60182, 61447, 13015, 91433 3 7/64 x 3 5/8 x 2 13/32 24 Vac DP30505001 C25DNJ350T 42DF35J 61460, 13619, 91531 50 120 Vac DP3050B5000 63 C25DNJ350 42DF35F 61461 3 208/240 Vac DP3050C5009 C25DNJ350B 42DF35G 60217, 60202, 61462, 13621, 91533 24 Vac DP30605000 C25FNF360T 42EF35J 61470 13625 91631 Q, S 60 120 Vac DP3060B5009 75 C25FNF360 42EF35F 61471 208/240 Vac DP3060C5008 LC C25FNF360B 42EF35G 60227, 60207, 61472, 13627, 91633 24 Vac DP30755016 C25FNF375T 42FE35J 60235, 61475, 13240, 91731 4 7/16 x 5 x 3 3/4 75 120 Vac DP3075B5015 4 7/16 x 5 x 3 3/4 95 C25FNF375 42FE35F 60237, 61476 208/240 Vac DP3075C5014 4 7/16 x 5 x 3 3/4 C25FNF375B 42FE35G 60245, 61477, 13242, 91733 90 120 Vac DP3090B5006 4 7/16 x 5 x 3 3/4 120 C25GNF390 42GE35F 61491 4 7/16 x 5 x 3 3/4 208/240 Vac DP3090C5005 120 C25GNF390B 42GE35G 60247, 61492, 13262 24 Vac DP40405001 C25ENF440T 42CF25J 61450, 13016 4 40 120 Vac DP4040B5000 2 5/8 x 3 3/4 x 3 7/64 50 C25ENF440 42CF25F 61451 208/240 Vac DP4040C5009 C25ENF440B 42CF25G 61452 Electric Heat Contactor 2 30 24 Vac R82461038 2 3/16 x 2 5/16 x 3 5/16 Q, S TCS, Q 48 @ 240 Vac, 277 Vac Furnas Mars SPECIL FETURES: First pole resistive only, second pole resistive/inductive combined; RI 780/790 rated For fan centers (relay and transformer combination), R8285 and R8239 NEM rated units offer low-voltage control of line-voltage fan motors and auxiliary circuits in heating, cooling or air-conditioning systems. Electrical Ratings (V) Electrical Ratings (Input Voltage) Switching Product Number Fan Centers NEM Rated Dimensions (in.) H x W X D Main Connections Secondary Connections Frequency Special Features DPDT R8239B1043 Super Tradeline* 40 V 120 Vac vailable only in DPST R8239D1007 Canada 4 1/2 x 4 3/16 x Yes DPST (1 Power, 1 Pilot) R8239D1015 3 3/32 Tradeline SPDT R82391052 L L Tradeline 50 V 120/208/240 Vac DPDT R8239B1076 Super Tradeline 120 Vac SPDT R82851048 Tradeline 40 V 4 3/16 x 4 1/2 x 120/208/240 Vac DPDT R8285B1053 No 2 13/16 Tradeline 50 V 120 Vac DPDT R8285D5001 Frequency: 60 Hz/50 Hz; B 60 Hz SPST: Single Pole Single Throw pprovals: UL, CS DPST: Double Pole Single Throw Temp Rating: -20 F to +105 F DPDT: Double Pole Double Throw Connectors: L Leadwires SPDT: Single Pole Double Throw Mounting: Standard 4 x 4 in. junction box * Super Tradeline models include extra hardware. Defrost Controller Choose the ST74 low-voltage time/temperature defrost controller for heat pumps. Resets the defrost cycle by remote contact closure. Mounts in outdoor section of heat pump. Utilizes special moisture barrier to protect circuitry. Defrost Controller Operation Time On Time Off Selectable Product Number Remote Contact Closure 10 min. 50/70/90 min. ST741053 uxiliary Switches Honeywell uxiliary Switches work Honeywell models of 3-pole contactors. Product Number Circuits Configuration DP3UX-1NO 1 Normally Open snap-on DP3UX-1NC 1 Normally Closed snap-on uxiliary Switches Dimensions (in.) H x W x D Contact Ratings (Resistive) Maximum (inrush) Current at 120/240/480/600 V Use With Heating/Cooling Devices Connectors: 46 BHS Binding Head Screw; Q Quick Connect; SS Sems Screw; CHS #10-32 Combination Head Screw; S #6 Screw; TCS Terminal Clamp Screw; LC Lug Connector pprovals: Temp Rating: -4 F to 149 F RI - 780: UL, CS 500,000 cycle mechanical life; 200,000 cycle electrical life; 10,000 cycle recycle life DP3UX-1NO- 1NC Normally Closed/Normally Open snap-on DP3UX-2NO 2 Normally Open snap-on DP3UX-2NC Normally Closed snap-on 2 26/32 x 2 17/32 x 7/16 10 60/30/15/12 mps DP3030 DP3090 Contactors 47