SERVICE MANUAL. 300 Series Motorized 35650, 35651, 35652, 36750, 36751, and Model

Similar documents
568X, 587X, 588X Series

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

OWNERS GUIDE TO INSTALLATION AND OPERATION

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S12 S16

SERIES 'HE' PLASTIC HORIZONTAL PUMP MODEL: H2 x1½

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S2 S4 S5 SS6 SS7 S8

SHURFLO 316 STAINLESS STEEL CLOSE-COUPLED SELF-PRIMING FLEXIBLE IMPELLER PUMPS OPERATION INSTRUCTIONS, PERFORMANCE, SPECIFICATIONS & PARTS MANUAL

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

316 Stainless Steel Close- Coupled Self-Priming Flexible Impeller Pumps

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

1 1/8 Inch Centrifugal Pump Operation and Maintenance Guide

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

SELF-PRIMING CENTRIFUGAL PUMPS BMLS-M & BMLS-H

Specifications Information and Repair Parts Manual 316A-95, 316B-95, 393A-95, 393B A-95 thru 394D-95, 399A-95

SuperKlean Washdown Products

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

569, 570, 571, 572 Series

569, 570, 571, 572 Series

Model 6050-Series. PumpAgents.com - buy pumps and parts online SELF-PRIMING PUMPS. Model 6050-Series

INSTRUCTION AND REPAIR MANUAL

Types TMUB, TMUAH and. J Jockey Pumps

OWNERS GUIDE TO INSTALLATION AND OPERATION END SUCTION CENTRIFUGAL PUMPS

AC 4 & 5 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions ASSEMBLY ELECTRICAL CONNECTIONS INSTALLATION

Chemical Motor Pump Unit BN

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

AC6/6H & AC8/8H Horizontal Metric Models

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

LC Series - Light Commercial Pump Station Installation and Operation Manual

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

MARLOW PUMPS RECIRCULATION

Owner's Manual. (200 Gallon Lawn Service Skid Sprayer) Technical Specifications. Operation. General Information. Warranty/Parts/Service

sta-rite Call C and CC Series Installation/Operation/Parts For further operating, installation, or maintenance assistance:

CAST IRON IMPELLER B4JRMBH. TYPE B SINGLE STAGE CENTRIFUGAL PUMP Bearing Frame Mount TABLE I

GP22/32 SERIES Sealed Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

CAR-MON DUST COLLECTORS SERIES 207, 2410, 3015

3020/3120 Series DEMING PUMPS. Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet

Vertical Inline Models

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

489 & 490 Series CAST IRON UNITS BRONZE UNITS STAINLESS STEEL UNITS MAINTENANCE. Figure 1 - Mechanical Seal Replacement

AXPR Wall Mounted Axial Panel Fans

Action Electric Drum Pumps

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

17 U.S. gallon portable low profile drain with electric pump

SPARUS 160 ENERGY EFFICIENT AQUACULTURE DUTY PUMP

This label warns for risk of electrical shock when failing to observe.

INSTRUCTION MANUAL DN0136 REVISION D

X1 series Submersible Drainage Pump

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

STATION MODEL: KPCG21-24x48 PUMP MODEL: KEEN KPCG21 VOLTAGE: 230 PHASE: 1 TANK DIMENSIONS: 24 DIAMETER X 48 DEEP

Dean Pump High Temperature Chemical Process Inline Pumps

DESCRIPTION MAINTENANCE INSTALLATION OF NEW SEAL REMOVAL OF OLD SHAFT SEAL

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

SECTION STEAM CONDENSATE PUMPS

INSTRUCTION MANUAL with Replacement Parts

SERIES ES BASE MOUNTED TURBINE PUMPS

Family Curve. Submersible Grinder Pumps 1¼" and 2" Discharge. Effluent/Grinder Pumps.

REF. NO Clamp Assembly 8 1 set Gasket (4 per set) S.S. Lock-washer 3/8 x 1/ Brass Impeller 3.

Oil burners fuel unit with solenoid valve

DNJ SERIES PUMPS END SUCTION CLOSE COUPLED

CPVC Horizontal. Series HV. Centrifugal Pump. Flows to 132 GPM Pressure to 81 Ft. TDH. Model HV-1 1/2DV

PENGUIN SERIES HSC PUMPS INTRODUCTION

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

E.2 series high efficiency circulator. Installation and operating instructions

STAINLESS STEEL UNITS

Oil burners fuel unit with solenoid valve

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Disposal Unit (BKSDU) Burger King Shortening. Operation, Service & Parts Manual BURGER KING BKSDU

VADA - V80-H PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

V80-H Multistage Pump Instruction Manual

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

HORIZONTAL AGITATOR ASSEMBLY

TECHNICAL DATA. Wet 26a. February 22, 2009

GALAXY FLOOR MACHINE

VL Series Pump. Owner s Manual. NOTE - To prevent potential injury and to avoid unnecessary service calls, read this manual carefully and completely.

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2

DESCRIPTION IMPELLER INSPECTION MAINTENANCE POWER CORD REPLACEMENT IMPELLER REPLACEMENT MECHANICAL SEAL REPLACEMENT IMPELLER INSPECTION /REPLACEMENT

INSTRUCTION MANUAL POWER DRIVE UNIT MODEL PAD-350 ONE YEAR LIMITED WARRANTY

SELF-PRIMING JET PUMPS

SHURflo Bronze Pedestal Self-Priming Flexible Impeller Pumps

CPE RANGE PUMPS CPE RANGE PUMPS. MODEL Nos: CPE15A1 15A3 20A1 20A3 30A1 30A3 PART Nos:

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 1

A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1

J SERIES. Technical Specifications. Centrifugal Pumps for J Series Condensate & Boiler Feed Pumps. Features

Installation and operating instructions. E.2 Series high efficiency circulator

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP

Series 47 and 247 Mechanical Water Feeders. Series 47-2 and Combination Mechanical Water Feeder/Low Water Cut-Off ! WARNING

Models Series Series

BSP4/BSPD4, BSP6/BSPD6 & BSPD8 Self-Priming Sewage and Trash Pumps. Installation and Service Manual

Models Series Series

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

Dogeroo & Super Dogeroo

Acquaer Ltd. H-4900, Fehérgyarmat, Szatmári út 11. CENTRIFUGAL PUMP Instruction Manual ACm60 / ACm75 / ACm150 / ACm150B2

ICED CAPPUCCINO MACHINE Taylor MODEL: 390

NHS VERTICAL AGITATOR

Transcription:

Section: MOYNO 500 PUMPS Page: 1 of 4 Date: March 1, 1998 SERVICE MANUAL MOYNO 500 PUMPS 300 Series Motorized 35650, 35651, 35652, 36750, 36751, and 36752 Model DESIGN FEATURES Housing: Cast iron/316 SS Pump Rotor: AISI 416 stainless steel/ansi 316 SS Pump Stator: NBR Seal: NBR (Nitrile) Motor Shaft: Mechanical (carbon/ceramic) Motor: 3 phase; 1-1/2 HP, 208/230/460V for Models 35650 and 35651; 2 HP, 230/460V for Models 36751 and 36750; 1 phase; 1-1/2 HP, 115/230V for Model 35652; 1 phase; 2 HP, 115/230V for Model 36752.60 Hertz, 1725 rpm, totally enclosed Note: Alternate elastomers available. Refer to Repair/ Conversion Kit Numbers, page 4. INSTALLATION Mounting Position. Pump may be mounted in any position. When mounting vertically, it is necessary to keep bearings above seals to prevent possible seal leakage into bearings. Pre-Wetting. Prior to connecting pump, wet pump elements and mechanical seal by adding fluid to be pumped into suction and discharge ports. Turn pump over several times in a clockwise direction to work fluid into pump elements. Piping. Piping to pump should be self-supporting to avoid excessive strain on pump housings. See Table 1 for suction and discharge port sizes of each pump model. Use pipe dope or tape to facilitate disassembly and to provide seal on pipe connections. Electrical. Follow the wiring diagram on the motor nameplate or inside the terminal box for the proper connections. The wiring should be direct and conform to local electrical codes. Check power connections for proper voltage. Voltage variations must not exceed + 10% of nameplate voltage. Motors do not have overload protection. To prevent damage to pump, pump rotation must be clockwise when facing pump from motor end. OPERATION Self-Priming. With wetted pumping elements, the pump is capable of 25 ft. suction lift with pipe size equal to port size. Be sure suction lines are air tight or pump will not self-prime. DO NOT RUN DRY. Unit depends on liquid pumped for lubrication. For proper lubrication, flow rate should be at least 10% of rated capacity. Pressure and Temperature Limits. See Table 1 for maximum discharge pressure of each model. Unit is suitable for service at temperatures shown in Table 2. Storage. Always drain pump for extended storage periods by removing bottom drain plug. To drain Model 36750, 36751 and 36752 remove suction housing bolts and loosen suction housing. Caution: Suction pressure should never be greater than discharge pressure. Table 1. Pump Data Pump Model 356 367 Suction Port 1-1/2 2 (NPT) Discharge Port 1-1/4 1-1/4 (NPT) Voltage Rating (VAC) See Motor Name Plate For Voltage Ratings Discharge Pressure (psig) (maximum) 50 50 NOTE: SSU = 5 x CP (approximate) specific gravity See Motor Name Plate For Voltage Ratings Table 2. Temperature Limits Elastomer Temperature Limits *NBR 10-160 F *EPDM 10-210 F *FPM 10-240 F *NBR = Nitrile EPDM = Ethylene-Propylene-Diene Terpolymer FPM = Fluoroelastomer

Page 2 TROUBLE SHOOTING WARNING: Before making adjustments, disconnect power source and thoroughly bleed pressure from system. Failure to do so could result in electric shock or serious bodily harm. Failure To Pump. 1. Motor will not start: Check power supply. Voltage must be ± 10% of nameplate rating when motor is in locked rotor condition. 2. Motor runs and thermally kicks out: Check for excessive pressure. Increase ventilation to motor. Do not use less than #14 wire size. 3. Stator torn; possible excessive pressure: Replace stator, check pressure at discharge port. 4. Flexible joint broken; possible excessive pressure: Replace joint, check pressure at discharge port. 5. Wrong rotation: Rotation must be clockwise when facing pump from motor end. Reverse the connections of any two line leads to the motor. 6. Excessive suction lift or vacuum. Pump Overloads. 1. Excessive discharge pressure: Check pressure at discharge port for maximum ratings given in Table 2. Fluid viscosity too high: Limit fluid viscosity to 100 CP or 500 SSU. Noisy Operation. 1. Excessive suction lift or vacuum: Maximum suction lift is 25 feet for water. 2. Suction line too small: Check pipe size. Be sure lines are free from obstructions. 3. Pump cavitates: Pump speed is 1725 rpm. Viscosity of fluid should not exceed 100 CP or 500 SSU. 4. Flexible joint worn: Replace joint. Check pressure at discharge port. 5. Insufficient mounting: Mount to be secure to a firm base. Vibration induced noise can be reduced by using mount pads and short sections of hose on suction and discharge ports. Seal Leakage. 1. Leakage at startup: If leakage is slight, allow pump to run several hours to let faces run in. 2. Persistent seal leakage: Faces may be cracked from freezing or thermal shock. Replace seal. Pump Will Not Prime. 1. Air leak on suction side: Check pipe connections. PUMP DISASSEMBLY WARNING: Before disassembling pump, disconnect power source and thoroughly bleed pressure from system. Failure to do so could result in electric shock or serious bodily harm. 1. Disconnect power source. 2. Remove suction and discharge piping. 3. Remove screws (112) holding suction housing (2) to discharge housing (1). Remove suction housing (2) and stator (21). 4. Rotor (22) can be detached from flexible joint (24) by using a punch to remove rotor pin (45). Support joint when removing pin. 5. Flexible joint (24) can be removed from motor shaft by using a punch through the discharge port to remove shaft pin (46). 6. Carefully slide mechanical seal (69) off motor shaft. 7. Remove discharge housing (1) from motor (70) by removing screws (112A and 112C) and washers (215). 8. Carefully pry seal seat out of discharge housing (1). If any part of mechanical seal (69) is worn or broken, the complete assembly should be replaced. Seal components are matched parts and not interchangeable. 9. Remove slinger ring (77). PUMP ASSEMBLY 1. Replace slinger ring (77). 2. Attach discharge housing (1) to motor (70) using lock washers (215) and body screws (112A). 3. Install mechanical seal (69) using the following procedures: a. Clean and oil sealing faces using light oil (not grease). Caution: Do not use oil on EPDM parts. Substitute glycerin or soap and water. b. Oil the outer surface of seal seat, and push assembly over motor shaft into the bore of the discharge housing (1) seating it firmly and squarely. c. After cleaning and oiling the shaft, slide the seal body along the shaft until it meets the seal seat. d. Install seal spring and spring retainer on shaft. 4. On Model 367, position seal spacer (69A) on motor shaft with slots away from seal (69). 5. Pin flexible joint (24) to motor shaft with shaft pin (46) using a punch through the discharge port. 6. Pin rotor (22) to flexible joint using rotor pin (45). Support joint while installing pin. 7. Slide stator (21) on rotor (22) carefully locating stator flange in housing groove. 8. Secure stator (21) and suction housing (2) to discharge housing (1) using screws (112). 9. Proceed as in installation instructions.

Page 3

Page 4 PARTS LIST Item Description Pump Model Numbers No. 35650 35651 35652 36750 36751 36752 1 Discharge Housing 350-0632-007 350-0632-000 350-0632-007 340-0951-007 340-0951-000 340-0951-007 2 Suction Housing 350-0489-000 350-0280-000 350-0489-000 350-0302-007 350-0302-000 350-0302-007 *21 Stator 340-3505-120 340-3506-120 *22 Rotor 320-6392-015 320-6392-000 320-4431-000 330-3077-000 330-2042-000 330-3077-000 24 Flexible Joint 320-1618-000 320-1749-000 *45 Rotor Pin 320-4069-003 320-4439-002 *46 Motor Pin 320-4069-005 320-4439-001 *69 Mechanical Seal 320-3945-000 320-1750-000 69A Seal Spacer 320-1737-000 70 Motor 330-7845-003 330-7845-000 330-8054-002 330-2802-004 300-2802-001 330-8053-004 72 Motor Support 320-4446-000 77 Slinger Ring 320-6385-000 103 Nuts (2 req.) 614-0010-111 (3/8-16) 112 Screw, Hex Hd 619-1530-161 (3/8-16 x 1) (4 req.) 619-1530-161 (3/8-16 x 1) (6 req.) 112A Screw, Hex Hd (4 req.) 619-1530-161 (3/8-16 x 1) 619-1550-161 (1/2-13 x 1) 112B Screw, Hex Hd (2 req.) 320-6918-000 (3/8-16 x 1-3/4) 215 Lock Washer 623-0010-411 (3/8) (4 req.) 623-0010-411 (3/8) (6 req.) 215A Lock Washer (4 req.) 623-0010-411 (3/8) 623-0010-431 (1/2) 261 Pipe Plug 610-0120-011 (1/8 NPT) * Recommended spare parts REPAIR/CONVERSION KIT NUMBERS (For cast iron pumps only) Item Model 35651 Model 36751 No Description NBR EPDM FPM NBR EPDM FPM Kit No. 311-9123-000 311-9125-000 311-9126-000 311-9060-000 311-9036-000 311-9124-000 21 Stator 340-3505-120 340-3505-320 340-3505-520 340-3506-120 340-3506-320 340-3506-520 24 Joint 320-1618-000 320-6508-000 320-6509-000 320-1749-000 320-6378-000 320-6515-000 69 Seal 320-3945-000 320-6380-000 320-6510-000 320-1750-000 320-6390-000 320-6517-000 46 Pin (Motor) 320-4069-005 320-4439-001 45 Pin (Rotor) 320-4069-003 320-4439-002 *NBR = Nitrile EPDM = Ethylene-Propylne-Diene Terpolymer FPM = Fluoroelastomer ABRASION RESISTANT SEALS Models Elastomer 356 367 NBR 320-6505-000 320-6511-000 EPDM 320-6506-000 320-6512-000 FPM 320-6507-000 320-6513-000 1999 by Moyno, Inc. Moyno is a registered trademark of Moyno Inc. Printed in U.S.A.

Double The Length Of Your Moyno Pump Warranty For FREE! For your free pump warranty extension, choose from one of the three options below: 1. Go to www.moyno.com and fill out the registration form online 2. Mail this form by placing it in an envelope and sending it to: Moyno, Inc. Attn: Tish Wilson 3. Fax this form to 937-327-3177 P. O. Box 960 Springfield, OH 45501-0960 U.S.A. Thank you for choosing a Moyno Pump. Please take the time to complete this warranty registration form.upon receipt of your form, your standard limited warranty on defective material and workmanship will be extended to twice the standard period of time at no additional cost to you. We appreciate your business and look forward to serving you in the future. MOYNO Always Insist on Genuine Moyno Replacement Parts! Moyno Pump Warranty Registration Pump Model # Pump Serial # Purchased From Date Purchased Your Name Your Title Your Company Name Address City/State (Province)/Zip Code Phone Number Fax Number E-mail Application for Which This Pump Was Purchased Material Flow Rate Process Temperature Operating Speed Viscosity ph Value Hours Operated per Day Continuous Intermittent Discharge Pressure Suction Pressure NPSH Available Percent of Solids Particle Size Abrasion Rating How Did You First Hear of Moyno Pumps? Advertisement Postcard Trade Show Referral Distributor Salesperson Previous Experience With Moyno Pumps Other Explain Below Thank You!