Universal Input Digital Panel Meter With Bargraph, NA3

Similar documents
Universal controller for panel mounting Models CS6S, CS6H, CS6L

DIGITAL PANEL METER N20 type

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

02/11/2015

02/11/2015

Process Alarm Module RTA 421

General Specifications

DIGITAL PANEL METER N20Z TYPE

CTT8 TEMPERATURE MONITOR DEVICE

MO n : 12JMC rév A

I/A Series 716C 1/16 DIN Temperature Controller

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

TEMON 4-C. Doc. N MO-0368-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL. Microener- Copyright 2010 FW 2.1 Date Rev.

4/8/12/16 Channel Temperature Scanner with FREE Data Logging PC Software RS485

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

Series Temperature Controller Instruction Sheet

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

Temperature Controllers

UDC 700 Universal Digital Controllers and Indicator Specifications

RS485 MODBUS Module 8AI

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit

920 Series. A dry contact relay is provided for alarm annunciation back to a distributed control system (DCS).

/8 DIN Level Indicator

Alarm Modules Section E

4 Ó â. Contactor RTA421. Contactor with loop power supply for monitoring currentorvoltagesignals. Technical information TI074R/09/en

Dew point set DS 400

Sentry G3 Machinery Protection Monitor

NOVUS AUTOMATION 1/5. Range: -35 to 720 C (-31 to 1328 F) Range: -90 to 1300 C (-130 to 2372 F) Range: 0 to 1760 C (-32 to 3200 F)

Electronic Temperature Controller 70304,

Analog Annunciator Unit SACO 16 A3. Product Guide

7EF/7HF/7EC/7ES Temperature Controllers

Nov 08 PRODUCT SPECIFICATION SHEET

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

itemp RTD TMT 187 itemp TC TMT 188 Temperature head transmitter

Sentry G3 Machinery Protection Monitor

Carbon Monoxide Transmitter

Series Digital Controller Instruction Sheet

Miniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version)

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

condition monitoring WP4086 Condition Monitoring System The WP4086 CMS System surveys vibrations with up to 8 external accelerometers

TAIE. Features. FY600 (96mm X 48mm) Application:Control temperature,humidity, FY Series Digital PID Controller

WP4086 Condition Monitoring System

SHIMADEN DIGITAL INDICATORS

MICROJET RECORDER (180mm)

Micro-DCI 4 Channel Indicator Totalizers Series 53IT5100

... RD0-TI-Ex8.FF.* Temperature Multi-Input Device for Cabinet Installation. Features. Assembly. Function. Connection. Zone 1

Two-Channel Gas Controller

TAIE. Features. FY900 (96mm X 96mm) Application:Control temperature,humidity, FY Series Digital PID Controller

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail

On the job around the clock 24/7: Fire detection systems

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

Operating Instructions Edition 02/2007

MICROJET RECORDER (24-CHANNEL 180mm)

DS 96/48 P. Digital indicator. Short manual 41/33-89 EN Rev. 00 DIM

Series SHR-5620 Digital Display Volumetric Meter Operation Instruction

3500/61E & 3500/67E Temperature Monitor

Bulletin 900-TC. Bulletin 900 TC Temperature/Process Controllers. Certifications. Bulletin 900-TC8 Controller Models

910 Series Single-point heat-tracing control system

Dual-point heat-tracing control system

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

Product Information. PipeMonitor District Heating Monitoring with Leak Localisation

Digital Heater Element Burnout Detector K8AC-H

PSE-369A. KL4000 SERIES 100mm chart DOT-PRINTING TYPE HYBRID RECORDER

Multi-Gas-Controller MGC2

UDC1000 & UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

IM 77J01A07-01E 1st Edition Nov th Edition Feb Fixed code 0 Always 0. Output-2 signal

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

PolyGard 2-channel Gas Controller MGC-03

USB Interface for setup program. 1 analog output standard signal. LCD display with white background lighting. 1 relay output pre-alarm ( KV)

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

M2500 Engine Controller Installation Manual

HTC-915-CONT. Heat-Trace Control system

XLH210: controller for gas leak detectors

E5CN/E5CN-U (48 x 48 mm)

Point recorder KS 3660

User s. Manual) Model VJS7 Potentiometer Converter (Multi-function) (Isolated Single-output and Isolated Dualoutput

Speed and Frequency Seite 1 von 7

LC1350 Level Controller

F4 Process Controller Installation and Operation Guide

SA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

BC3250. Blowdown Controller

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

Advanced Test Equipment Rentals ATEC (2832)

Temperature Measurement Transmitters for field mounting

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

MICROJET RECORDER (180mm)

User's Manual. Model VJQ8 Pulse to Analog Converter. (Multi-function) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT

ORDERING INFORMATION FEATURES EL-WIN-USB (CONTROL SOFTWARE) Maximum Speci cations Typical Minimum Unit

Electrical installation solutions for buildings Technical details Energy efficiency

Transcription:

products Panel Panel Meters Digital Universal Input Digital Panel Meter With Bargraph, NA3 Universale input (programmable) Wide voltage, AC/DC control 4 digit, With or without 3/7 colour bargraph

Description Programmable meters with multicolour bargraph indicators NA3, NA5 and NA6 type are destined to measure and recording d.c. current or d.c. voltage, temperature, resistance and other non-electrical magnitudes like: level, flow, pressure, humidity, h Meters with bargraph are devices ensuring both a high measurement accuracy and very well visualization of the measuring process courses. Good visualisation of the process is possible using meters in 3 and 7 coloured bargraph built with diodes made in the gallium nitride technology. They can find application in various industrial fields, e.g.food industry, pumping stations and savage-treatment plants, chemical industry, weather stations, brewing industry and many other fields where they are destined for visualisation of the measured value and evaluation of the monitored manufacturing process change trend. They can also find application in automation systems where programmable controllers are applied. input: programmable voltage: 0...300 mv, 0...200V, - 5...60V current: 0...200 ma, 0...2A thermocouple, resistance thermometers 0...4/10Ω output: programmable - analog, relay (up to 8 relays in meter NA6 type ), digital RS-485 with MODBUS protocol supply: 95...230...253 V a.c./d.c., 20...24...40 V a.c./d.c. Kinds of execution: NA3 type horizontal, 1-measuring channel in 3 options: with bargraph, with bargraph and display, only with display NA5 type vertical, 1-measuring channel, with bargraph and display NA6 type vertical, 2-measuring channels, with 2 bargraphs and 2 displays. Next to programmable measuring functions meters have many additional functions: measurement of the input quantity and displaying it on the LED display and on the bargraph evaluation of the input signal into the indication on the base of the individual linear characteristic arithmetical: raising to a power, extraction of roots(additionally in NA6 type, operations in channels: summation, subtraction, multiplication, division) programming of the bargraph colour and resolution signalling of the set alarm value exceeding recording of the measured signal in programmed time intervals memorisation of maximal and minimal values programming of the measurement averaging time programming of the indication resolution lockout of parameter introduction by means of a password servicing of the RS-485 interface in MODBUS protocol, both in ASCII and RTU mode galvanic isolation fixing in the panel External dimensions: 96 x 24 x 125mm (NA3 type)

Example of application Technical

Kind of input Measuring range Pt100-200...850 C Pt500-200...850 C Pt1000-200...850 C J (Fe-CuNi) -30...1100 C K (NiCr-NiAl) -50...1370 C N (NiCrSi-NiSi) -100...1300 C E (NiCr-CuNi) -20...850 C R (PtRh13-Pt) 0...1760 C S (PtRh10-Pt) 0...1760 C T (Cu-CuNi) -50...400 C Resistance 0...400 Ω, 0...4000 Ω 0...60 mv, Rinp. > 9 MΩ 0...3 V, Rinp. > 4 MΩ Voltage 0...10 V, Rinp. > 4 MΩ 0...200 V, Rinp. > 4 MΩ 0...600 V, Rinp. > 4 MΩ 0...5 ma, Rinp. = 4 Ω Current 0...20 ma, Rinp. = 4 Ω 0...2 A, Rinp. = 10 mω ± 10% 0...5 A, Rinp. = 10 mω ± 10% Inputs Outputs Kind of output Features galvanic isolation with resolution 0.025% of range current programmable 0/4...20mA Analogue output load resistance 500Ω or voltage programmable 0...10 V load resistance 500Ω output response time: 100ms 1 or 2 relays NOC voltageless contacts maximum load carrying capacity: Relay output - voltage: 250 V a.c. 150 V d.c. - current: 5A 30 V d.c., 250 V a.c. - resistance load: 1250 VA, 150 W voltageless of OC type with npn transistor Open collector maximum load: 25 ma (OC type) range of appended voltages: 5...24 V d.c. interface type: RS-485 transmission protocol: MODBUS ASCII Digital (8N1, 7E1, 701), RTU (8N2, 8E1, 8O1, 8N1) baud rate: 2400, 4800, 9600 bit/s

Readout field External Features NA3-F 4 LED displays with 7 segments, digits of 7 mm high, indication range -1999...9999 NA3-B multicoloured bargraph as above NA3-D 4 LED displays with 7 segments, digits of 14 mm high, 3 alarm diodes, indication range as above Weight < 0.3 kg Overall dimensions 96 x 24 x 125 mm panel cut-out: 92+0,5 x 22.2+0,5 mm Protec! on grade (acc. to EN 60529) IP40 from frontal side IP20 from terminal side Rated Operating Conditions Supply voltage 95...253 V a.c./d.c. 20...40 V a.c./d.c. Power consumption < 8 VA Temperature ambient: -10...23...55 C Storage: -25...85 C Relative humidity < 95% Condensa! on inadmissible Safety and Compatibility Requirements Electromagnetic compatibility Noise immunity acc. to EN 61000-6-2 Noise emissions acc. to EN 61000-6-4 Safety requirements acc. to EN 61010-1 Connection diagram

Input Bargraph Alarm 1 Alarm 2 Alarm 3 Output Programmable parameters of the NA3 meter Input type typ Mathematical functions Func Kind of compensation Con Measuring averaging time Cnt Displayed characteristic Indi Measured value I_H1 Displayed value d_y1 Measured value I_H2 Displayed value d_y2 Bargraph type typb Bargraph colour colr Lower bargraph threshold brl Upper bargraph threshold brh Lower alarm threshold PrL Upper alarm threshold PrH Alarm type typa Delay of alarm operation dly Support of alarm signalling HOLd Colour of the lower threshold alarm index CurL Colour of the upper threshold alarm index CurH Lower alarm threshold PrL Upper alarm threshold PrH Alarm type typa Delay of alarm operation dly Support of alarm signalling HOLd Colour of the lower threshold alarm index CurL Colour of the upper threshold alarm index CurH Lower alarm threshold PrL Upper alarm threshold PrH Alarm type typa Delay of alarm operation dly Support of alarm signalling HOLd Colour of the lower threshold alarm index CurL Colour of the upper threshold alarm index CurH Output characteristic IndO Displayed value d_h1 Value on the analog output O_Y1 Displayed value d_h2 Value on the analog output O_Y2 RS-485 baud rate baud Kind of RS-485 transmission tryb Device address Adr

Ordering code Example of Order: The code: NA3 - F T R U 0 1 1 0 00 8 means: NA3 -digital meter with bargraph of NA3 type F -with a bargraph and digital display T -with a 3-colour display R -red display colour U -universal input 0 -lack of analogue output signal 1 -additional output: RS-485 digital output + 1 relay 1 -supply voltage: 95...253 V.a.c./d.c 0 -socket screw plug 00 -standard version 8 -without extra quality requirements