Flush-Mount Backing. Flush-Mount ADA Compliant Backing (pat# 5,189,857) :

Similar documents
DESIGN AND CONSTRUCTION STANDARDS SPECIFICATION GUIDELINES

ADA Checklist Transient Lodging, Hotels, Motels, Inns, Boarding Houses, Dormitories and similar facilities

D & L A.D.A. SOLUTIONS 448 WEST MAIN ST. AUBURN,WA (800) HOUR FAX (206) FROM THE PARTS PEOPLE. SUPPLY and MFG.

Plumbing Guidelines 2012 IBC/ANSI A

Residential Accessibility Checklist - for Unit Types A and B With Connecticut Amendments Type A Units Accessibility Requirements rev.

SECTION XPRESS II INCLINED WHEELCHAIR PLATFORM LIFT. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

Home Safety Checklist From Adaptive Remodeling Solutions, LLC Monona, WI

Plumbing Guidelines 2015 Minnesota Accessibility Code Based on the 2012 IBC and 2009 ANSI A117.1

Facilities Procedure for Accessibility or Compliance Related Requests:

ADA Checklist AIRPORTS

A. Section Masonry Assemblies: Anchor placement in masonry.

GSL Artira Inclined Lift Specifications L DS Section

Aging-In-Place Remodeling Checklist

RITTNER FRENCH ASSOCIATES Rittner French Associates / Rittner Products, Inc.

Triple Gel Coat Walk in Tubs A1A Ultimate Edition

#PSBTWE1000 INSTALLATION GUIDE

Solutions and Cost Estimates Johnson Gill Annex and Courthouse 1 Kings Highway Middletown, NJ

Garaventa GSL Artira Inclined Platform Lift

PLUMBING FIXTURES Reserved

BATHROOM FOR ALL GENERATIONS. STYLISH ATTRACTIVE MEMORABLE

Unit # E ± 1,200 SF Width ± 20' Depth ± 60'

For the Lifespan: The Caregiver Guide Module 4 The Accessible Home

A Home Safety Checklist

Maintaining Seniors Independence Through Home Adaptations A SELF-ASSESSMENT GUIDE

Inspection Checklist. Kitchen

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2017

SECTION INCLINE WHEELCHAIR LIFTS. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

COX DISTINCTIVE DOOR SYSTEMS.

HUTS SANITATION TANKS, DRUMS & BINS PIPING

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 12/12/2018

SAFETY WITH STYLE IN THE BATH

BUILDER S PRE-INSPECTION CHECKLIST

Unit # H ± 2,000 SF Width ± 25' Depth ± 80'

ROVAL COLLECTION PAPER TOWEL DISPENSERS TOILET TISSUE DISPENSERS MIRRORS AUTOMATIC HAND DRYERS

Working with. Safe at Home: Tips for the Over-65s

disasterrelief.com 3 Phase Sanitation Plan By

BUILDER S PRE-INSPECTION CHECKLIST


sanctuary walk-in bathtubs PROUDLY BROUGHT TO YOU BY

HOW TO SELECT CABINETS

Beautifully crafted for your peace of mind. Smartly designed for your sense of style.

Staying Independent. A Fall Prevention Checklist

Behavioral Health Series

Safe at Home. Suggestions for Homeowner Created in partnership with the Administration on Aging. Assessor: Assessor: Homeowner Name: Address:

JAMES P. KISSANE, ARCHITECT

Seniors Home Program

Cubicles > chplenclose

Accessible Showers and ADA Showers

Checklist. Your Home Safety. Staying On Your Feet. A few simple steps can make your home safer and help prevent you from falling

ASI Guide Specification

Cubicles > glassbox-t

Cubicles > glassenclose

walk-in bathtubs Thank you for choosing an AmeriGlide Sanctuary Walk In Tub, the world s highest quality walk-in bathtub.

University of Delaware

Home Safety Checklist *

Making Crimp Connections

Cubicles > glassbox-f

A Home Safety Checklist

AGING IN PLACE CHECKLIST Use this checklist to identify fall hazards and accessibility for the homeowner and family members.

Use a minimum loading pad 6' curb length of a hard surface to connecting curb and sidewalk.

5SLR52XXD-B Series Fan UL Model No. : 5SLR52. Owner s Guide and Installation Manual

WALL MOUNTED SHOWER SYSTEMS

5CO52XX Series Fan UL Model No. : 5CO52. Owner s Guide and Installation Manual. Attach sales receipt to this card and retain as your proof of purchase

Building Dimensions Custom Dimensions Available

Unit # 1038 ± 900 SF Width ± 15' Depth ± 60'

DESIGN STANDARDS SECTION PLUMBING FIXTURES AND EQUIPMENT. 1.3 Wall hung toilet room fixtures. Urinals for handicapped may be stall type.

UNLIMITED FREEDOM. EVERYWHER

A U TO S M O K E. Model AUTO SMOKE FIRE SHUT Flat Slats Fire Shut Rolling Doors

BC Building Code Checklist Part 3 Planning and Development Department

3VNR52/42XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3VNR52XXD / 3VNR42XXD

Product Specification

CHAPTER 4 FIXTURES WHAT FIXTURES ARE REQUIRED? SINGLE-FAMILY RESIDENCE

DATE OF PURCHASE: RETAILER NAME: MODEL NUMBER: RETAILER ADDRESS:

Accessible Home Design and Remodel Checklist

Suitability of the house for those with disabilities - Living Elements. ACCESSIBILITY STATEMENT

Condensate Removal Pumps for Air Conditioner PB PE-60245

PERFORMANCE EVALUATION TEST REPORT. Rendered to: GREENFIELD MANUFACTURING COMPANY. PRODUCT: Hanger Screws

5GFR52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5GFR52XXD

DESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point.

Universal Design Recommendations for Accessible Housing. Mauricio A. Lizama, Ph.D., ATP

Ceiling Fan Installation Instructions

5AZR56XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5AZR56XX

3CLMR56XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3CLMR56XXD

Guardrail and Barrier Systems

TUBS & SURROUNDS FIBERGLASS TUB STANDARD FIBERGLASS GARDEN TUB

Unit HH Gregg. ± 30,000 SF Width ±26' Lakeland Retail Center. Lease Outline Drawing. Unit HH Gregg. Depth ± 145' HVAC Units & Information

Preliminary Study Document. Horicon. Horicon, Wisconsin

2). Crane Co. 4). Kohler Co. 5). Universal-Rundle Corp. Revised September 29, 2017 Commercial Plumbing Fixtures

Cubicles > glassbox-f

Shower Column and Shower Seat Catalog

Life Safety Checklist

Lowe s Accessible Home LIVE RIGHT. Solutions for life s changing needs

AD HOC HEALTHCARE COMMITTEE MEANS OF EGRESS WORK GROUP APPROVED CODE CHANGE DRAFTS CODE GROUP B MOE COMMITTEE

The Professional Choice

PLAN REVIEW SUBMITTAL GUIDE

Adaptive Gardening Tips and Techniques

2018 PRODUCT CATALOG

5DI52XXD/5DI52XXD-L Series Fan UL Model No. : 5DI52. Owner s Guide and Installation Manual

Chapter 6: Plumbing Elements and Facilities. 603 Toilet and Bathing Rooms Wheelchair Accessible Compartment

3DIR52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3DIR52XXD

Transcription:

Flush-Mount Backing Flush-Mount ADA Compliant Backing (pat# 5,189,857) : Flush-Mount is the backing solution that is easy and fast to install between studs when a smooth wall is demanded. UL Tested to 250 push/pull point load complying with ADAAG Section 4.26. Mounts in a straight line for path of travel in hospitals, schools, etc...available in 14 gauge. Meets the requirements of the Americans with Disabilities Act Accessibility Guidelines (ADAAG), the BOCA (1999), Standard Code (1997), and UBC (1997) model building codes, the International Building Code 2000, and both the ICC/A117.1-1998 Section 609 (Grab Bars) Section 610 (Seats) and ANSI/ASCE 7-98 Standards. All Rights Reserved. Copyright 2013 Page 1

(Americans with Disabilities Act Accessibility Guidelines) ADAAG Section 4.26 4.26 Handrails, Grab Bars, Tub and Shower Seats. 4.26.1* General. All handrails, grab bars, and tub and shower seats required to be accessible by 4.1 (application), 4.8 (ramps), 4.9 (stairs), 4.16 (water closets), 4.17 (toilet stalls), 4.20 (bath tubs) or 4.21 (shower stalls) shall comply with 4.26. 4.26.3 Structural Strength. The structural strength of grab bars, tub and shower seats, fasteners, and mounting devices shall meet the following specification: (1) Bending stress in a grab bar or seat induced by the maximum bending moment from the application of 250 lbf (1112N) shall be less than the allowable stress for the material of the grab bar or seat. (2) Shear stress induced in a grab bar or seat by the application of 250 lbf (1112N) shall be less than the allowable shear stress for the material of the grab bar or seat. If the connection between the grab bar or seat and its mounting bracket or other support is considered to be fully restrained, then direct and torsional shear stresses shall be totaled for the combined shear stress, which shall not exceed the allowable shear stress. (3) Shear force induced in a fastener or mounting device from the application of 250 lbf (1112N) shall be less than the allowable lateral load of either the fastener or mounting device or the supporting structure, whichever is the smaller allowable load. (4) Tensile force induced in a fastener by direct tension force of 250 lbf (112N) plus the maximum moment from the application of 250 lbf (1112N) shall be less than the allowable withdrawal load between the fastener and the supporting structure. (5) Grab bars shall not rotate within their fittings. ICC/A117.1-2003 Section 609 (Grab Bars) Section 609 (Grab bars) 609.8 Structural Strength. Allowable stresses in bending, shear, and tension shall not be exceeded for materials used where a vertical or horizontal force of 250 lb (1112 N) is applied at any point on the grab bar, fastener mounting device, or supporting structure. Section 610 (Seats) 610.4 Structural Strength. Allowable stresses in bending, shear, and tension shall not be exceeded for materials used where a vertical or horizontal force of 250 pound (1112 N) is applied at any point on the seat, fastener mounting device, or supporting structure. All Rights Reserved. Copyright 2013 Page 2

Flush-Mount ADA Compliant Backing (pat# 5,189,857) Flush-Mount Backing is the only product on the market today to meet the requirements of the Americans with Disabilities Act Accessibility Guidelines 4.26 (ADAAG), the BOCA (1999), Standard Code (1997), and UBC (1997) model building codes, the International Building Code 2000, and both the ICC/A 117.1-2003 Section 609 (Grab Bars) Section 610 (Seats) and ANSI/ASCE 7-98 Standards. Flush-Mount is the only product ever tested to UL Standards requiring 250 pull/point load for handrails, grab bars, and seats. Replaces: Steel Plate Backing Steel Plate backing has never been UL Tested to 250 lbs pull/point load and does not pass any code. Flat Strap Backing Flat strap backing has never been UL Tested to 250 lbs pull/point load and does not pass any code. Flush-Mount Backing is the most cost effective means where ADA Code applies and a smooth wall is needed. No other product on the market today can accomplish this with full code compliance. Flush-Mount is the only patented backing system that meets ADA Code with a smooth wall. All Rights Reserved. Copyright 2013 Page 3

All Rights Reserved. Copyright 2013 Page 6

Here is an example of our Flush-Mount Backing assembled for the installation of a baby changing station. Our patented design allows 8 inches of lateral movement as well as 2 inches of vertical movement. Metal-Lite's P.E. stamped Backing system is the only ADA Code Compliant product on the market. All Rights Reserved. Copyright 2013 Page 7

This rendering illustrates the versatility of Metal-Lites patented Flush-Mount backing system that allows your wall mounted applications to be positioned at any location along your wall. Metal-Lite has the only Code Compliant Backing available. All Rights Reserved. Copyright 2013 Page 8

Metal-Lite's patented Flush-Mount Backing is the only installation solution for continuous Handrails that meet ADA and all nationwide code requirements. This backing system can also be used for the installation of individual applications. All Rights Reserved. Copyright 2013 Page 9

The example above represents the adaptability of Metal-Lites Flush-Mount Backing which is the only product on the market today to meet the requirements of the Americans with Disabilities Act Accessibility Guidelines. All Rights Reserved. Copyright 2013 Page 10