The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

Similar documents
intelligent fire alarm ID60series panels

ID50series. intelligent fire alarm panels

ZXSe Range Data Sheet

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

ID2000. intelligent fire alarm panel


ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

ID3000 intelligent. fire alarm panel

System 800 Addressable Fire Detection & Alarm System

Excel-EN Conventional Fire Control Panel

ID3000 intelligent. fire alarm panel

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide

DXc Control Panels. DXc1. DXc2. DXc4. Single Loop Control Panel, 230Vac, 2 sounder circuits. Dims 260 x 390 x 147mm (H x W x D)

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

Discovery 1-4 Loop 96 Zone, 40-Character Analogue Addressable Control Panel. Application Guide

user manual Document No , Revision 03 November 2015

Intelligent Security & Fire Ltd

The EN54 Part 2 & 4 Fire System

Components Brochure DX CONNEXION

Document No Issue 02 operation & installation manual. ZXr-A ZXr-P

Installation, Operating and Maintenance Manual

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

Product Data Sheet. Remote Terminals. Features:

ZSC100 Gas Detection and Alarm System Controller

OPERATION AND INSTALLATION MANUAL

Discovery 4 Loop Analogue Addressable Control Panel (NVI & NVA series Protocols)

The EN54 Part 2, 4 and 13 Fire System

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Document No Issue 4 user manual

Application, Installation, Operation & Maintenance Manual

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Conventional & Twin-wire Fire System

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Conventional Fire Alarm System 2014 V1.2

Syncro Matrix Analogue Addressable Fire Alarm Mimic Panel Product Manual

ID2000. operating manual

Product Catalogue. Intelligent Control Equipment for Life Safety. Issue 1

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

C E R T I F I C AT LPCB I O N B O A R D P R E V E N T L O S S. Cooper Fire Systems

Fire control panels FC360

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Advanced FireAlarm Panel 1-4Loop

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Intelligent Security & Fire Ltd

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

Precept Marine Control Panel Application Guide

SOLO Single Loop Addressable Fire Control Panel

Technical Data Sheet

Fire Alarm Control Panel EN54 2 & Operation & Programming MAN

An introduction to... Sigma

FIRE BRIGADE RESPONSE GUIDE. LoopSense. Fire Alarm Control Panel (AS4428 & AS & 4) Operation & Onsite Programming MAN

Reliably Advanced Extinguishing Control

Sita200plus. 200detectors. Single loop analogue addressable System

Intelligent Security & Fire Ltd

SALES SUPPORT DOCUMENT

RP1r-Supra / VSN-RP1r+ / ESS-RP1r-Supra Extinguishing Control Panel User Manual. HLSI-MN-103I v.06 September 2017

QA16 Addressable System

Laptop / PC Programming Manual

MINERVA MX. 800 Series Ancillary Equipment

Menvier Fire System MF9300

SmartTerminal AS7240. Installation and Operation Guide MAN2990-1

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

Algo-Tec 6500/6600 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS)

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

Installation & Commissioning Manual

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

Reliably Advanced Extinguishing Control

TrueAlarm Fire Alarm Controls

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Control Panel Engineering and Commissioning Instructions

2018 Johnson Controls. Tyco Fire & Security GmbH, Victor von Bruns-Strasse 21, 8212 Neuhausen am Rheinfall, Switzerland DUO-CEL

OPERATION / INSTALLATION

Protec. Protec Algo-Tec TM 6500 Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network. Fire Detection - Addressable

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections.

CONVENTIONAL FIRE CONTROL PANELS FS 5100 and FS 5200

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

ID50/60. installation, commissioning & configuration manual

INTELLIGENT FIRE ALARM CONTROL PANEL

Conventional Leaflets

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

DS7400Xi Addressable Control/ Communicator

VSN-RP1r Extinguishing Control Panel. User Manual (Software version 3.x) by Honeywell. doc. MIE-MN-570I rev.008

LifeAlarm Fire Alarm Control Panels

Input/Output Modules Data Sheet

4 wire conventional alarm system

Vigilant MX4428 Fire Alarm System

JUNO-NET. Fire Alarm Control Panel OPERATION & MAINTENANCE MANUAL

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

SIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL

Saxon Range 1-8 Zone Convertional Control Panels

Protec. Protec Algo-Tec TM 6500 Open Protocol Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network

Air Sampling Smoke Detection

Protec. Protec Algo-Tec TM 6400 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Control Panel User Guide (TO BE RETAINED BY THE USER)

Transcription:

990-052, Issue 6 20 March 2006 ID50 Series Single Loop Intelligent Fire Alarm Panels Section: Intelligent Fire Alarm Panels GENERAL The NOTIFIER ID50 series single loop intelligent fire alarm panels, has been developed for both installers and end users with efficiency in mind, offering a technically advanced range of facilities and functions while remaining easy to install, program and operate. 3 modules are available in the ID50 series, the basic ID50, the ID51 with printer option and the ID52 with printer option and space for 72 hours battery back up. The ID50 series has a capacity of 99 sensors and 99 input / output modules on the single loop. The panels have been certified to EN54 parts 2 and 4 requirements and will be produced to various European languages and local requirements as options. The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES Intelligent Features Certified to EN54 parts 2 and 4 One loop capacity (99 sensors and 99 modules) 16 fire zones, 16 non fire zones 64 CBE rules Filter by device type Printer option 72 hours backup option Adjustable sensor sensitivity Automatic High Test Day/Night mode facility Class Change Active and passive repeaters Programmable from the panel keypad or PC Two on board sounder circuits Two on board configurable outputs Autolearn facility Unconfigured device detection One man "Walk Test" by zone 512 event Historic Log Duplicate address fault monitoring Coincidence function Loop powered sounder support Non-latching Plant Alarm function Pulsing sounders support Output delay functions Remote Reset function 3 second response to manual call point activation Alarm verification algorithm Internal diagnostics program Fully on-site configurable Windows off-line configuration tool Loop and Battery calculator 20 characters of configurable zone text. 20 characters of configurable device location text User Interface 16 zone indications of fire and fault, disablement/test 2 Lines of 40 characters each on a backlit LCD Real time clock for timestamping of events 11 configurable passcodes for access restriction This document is not intended to be used for installation purposes. Every care has been taken in the preparation of this document but no liability can be accepted for the use of the information therein. Design features may be changed or amended without prior notice. For more information, contact NOTIFIER. Charles Avenue, Burgess Hill, West Sussex, RH15 9UF. United Kingdom Phone: +44 (0) 1444 230 300 Fax: +44 (0) 1444 230 888 ISO9001 Design, Manufacture and Supply to Quality Management Systems Certified to ISO9001:1994 Quality Systems Certificate No. 154 Assessed to ISO9001 Page 1 of 6 990-052 Issue 6

Numeric and Navigation keys Plant Alarm (Non-Fire) LED indication Housing Two part, mild steel cabinet Plastic moulded insert Passive Repeater A compact mild steel housing incorporates all electronics for the fully monitored repeater unit A 2 x 40 character LCD indicates all information Incorporated status LED s for FIRE,, DISABLEMENT, POWER, PRE-ALARM, TEST, DELAY ACTIVE, SYSTEM and COMMUNICATIONS LOSS Any combination of up to 16 total Passive/Active repeaters may be connected to a single ID50 Series Panel which will require an RS485 Interface Module PCB to be fitted in order to communicate Requires a 24V DC source at 90mA max. for power Optional semi-flush mounting Bezel Active Repeater A compact mild steel housing incorporates all electronics for fully the monitored repeater unit A 2 x 40 character LCD indicates all information Incorporated status LED s for FIRE,, DISABLEMENT, POWER, PRE-ALARM, TEST, DELAY ACTIVE, SYSTEM and COMMUNICATIONS LOSS are included, and control pushbuttons for MUTE BUZZER, END DELAY/EVACUTATE, SILENCE/RESOUND and RESET A keyswitch provides restricted access to control pushbuttons Any combination of up to 16 total Passive/Active repeaters may be connected to a single ID50 Series Panel which will require an RS485 Interface Module PCB to be fitted in order to communicate Requires a 24V DC source at 90mA max. for power Optional semi-flush mounting Bezel Windows Configuration Tool Simple to use Offline Configuration Simple to use Output Configuration Simple to use Text entry SYSTEM MODULES The ID50 Series Panel is available with the following modules. Choose from the required modules below. Each kit is supplied with all required fixings and installation instructions. 002-455 ID50 Panel ID50 single loop intelligent fire alarm panel. Complete with 16 zonal LED's, sounder circuit, 1.5A power supply and space for 12Ah batteries. Black/Grey. LPCB Approved. 002-462 ID51 Panel ID51 single loop intelligent fire alarm panel. Complete with 16 zonal LED's, sounder circuit, separate 3A power supply, printer option and space for 12Ah batteries. Black/Grey. LPCB approved. 002-460 ID52 Panel ID52 single loop intelligent fire alarm panel. Complete with 16 zonal LED's, sounder circuit, separate 3A power supply, printer option and space for 42Ah batteries. Black/Grey. LPCB approved. 020-644-009 PRN-ID Printer Module Kit for ID51/ID52 Includes thermal printer with power supply unit and roll of thermal paper. 020-553 RS485 Interface Module PCB Kit ID50 Includes the RS485 Interface Module PCB required for repeater interfacing to the ID50 Panel. Plugs into dedicated socket on ID50 Panel PCB Assembly. Includes instruction sheet and fixings. 020-479 RS485 Interface Module PCB Kit ID51 / 52 Includes the RS485 Interface Module PCB required for repeater interfacing to the ID51 / ID52 Panel. Plugs into dedicated socket on ID51 and ID52 Panel PCB Assemblies. Includes instruction sheet and fixings. Page 2 of 6 990-052 Issue 6

002-451 IDR-2P Passive Repeater Includes the complete passive repeater unit with all a s s e m b l e d electronics, Liquid Crystal Display (LCD), Fascia membrane and manual. 002-450 IDR-2A Active Repeater Includes the complete active repeater unit with all a s s e m b l e d electronics, Liquid Crystal Display (LCD), Control pushbuttons, Access control keyswitch, Fascia membrane and manual. 020-573 Mimic Control PCA Kit Supports up to 8 Mimic Drivers. Requires external 24Vdc power. 020-574 Mimic Driver & Terminal Board PCA Kit Provides 64 LED s or Relay outputs and 8 inputs. Up to 8 Mimic Drivers can be daisychained. Requires Mimic Control PCA kit and external 24Vdc power. 020-741 Kit IDR-CM (LCM) Main PCB IDR-CM Compact Mimic driver. Provides 16 programmable LED outputs, common fire, fault, test and disablement outputs and power OK output. Accepts a keyswitch input to enable evacuate, silence, lamp test, mute and reset inputs. Expandable with up to 9 additional driver boards each providing 16 additional programmable outputs (020-742). Requires 24Vdc and RS485 connection. 020-742 Kit IDR-CME (LCM) Expansion PCB IDR-CME Compact Mimic Expansion board. Provides 16 additional programmable LED ouputs. Requires Compact Mimic driver board (020-741). 020-599-009 ID50 Semi-flush Bezel Kit Includes semi-flush mounting bezel for ID50 Black/Grey and instruction sheet. 020-038-009 ID51 Flush Bezel Kit Includes flush mounting bezel for ID51, Black/Grey and instruction sheet. 020-039-009 ID52 Semi-flush Bezel Kit Includes flush mounting bezel for ID52, Black/Grey and instruction sheet. 020-600-009 Flush Bezel for IDR Repeaters Flush mounting bezel for IDR repeaters, Black/Grey. 020-562 ID50 Support Tool Kit Including Offline Configuration software, on-line manual and interconnection cable assembly. PANEL SPECIFICATIONS Primary Input Power ID50-230V, 50Hz, 1.0A ID51-230V, 50Hz, 1.6A ID52-230V, 50Hz, 1.6A Sounder Outputs 2 Sounder outputs rated @ 30V 1A each Sounder / Volt-free Outputs 2 Sounder / Volt-free outputs rated @ 30V 1A Note... Default as general fire and fault relay contacts. Open - Collector Outputs 2 configurable outputs rated together @ 60mA total output Auxiliary Output 24V Auxiliary Output rated @ 250mA Page 3 of 6 990-052 Issue 6

Power Supply / Battery Charger ID50 - Maximum 1.5A total output, 0.5A for battery charger, supporting 12Ah batteries to EN54 ID51/52 - Maximum 3A total output, 2.2A for battery charger, supporting 42ah batteries to EN54 Maximum of 1A available in alarm for sounders etc. Digital Input 1 configurable input defaulting to Level 2 access control Dimensions ID50 365 380 110 Weight ID50-6kg without batteries. ID51-9.5kg without batteries. ID52-15.5kg without batteries. Battery Space ID50 - Maximum 2 x 12V, 12Ah batteries ID51 - Maximum 2 x 12V, 12Ah batteries ID52 - Maximum 2 x 12V, 42Ah batteries Cable Access ID50-16 x 20mm knockouts in top of cabinet ID51-25 x 20mm knockouts in top of cabinet ID52-25 x 20mm knockouts in top of cabinet Dimensions Weight 750g Cabling Maximum 1200 metres communications cable with 150R terminating resistors at both ends Cable Access 5 x 20mm knockouts in top of cabinet 3 x 20mm knockouts in back of cabinet Environmental Limits Environmental Limits ID51 500 122 Climatic Classification : 3K5, (IEC 721-2-3) Operating Temperature : -5 C to +45 C Climatic Classification : 3K5, (IEC 721-2-3) Operating Temperature : -5 C to +45 C Humidity : 400 Humidity : 5% to 95% R.H. Panel Sealing : 5% to 95% R.H. Panel Sealing : IP 30, (EN 60529) ID52 IP 30, (EN 60529) 220 REPEATER SPECIFICATIONS 620 Primary Input Power 18-32V DC (+10%, -15%) Current Consumption Note... 90mA rated @ 24V DC All dimensions are in Millimetres Communications RS485 Page 4 of 6 990-052 Issue 6

PANEL CONTROLS AND INDICATORS Led Status Indicators FIRE DISABLEMENT TEST DELAY ACTIVE FIRE OUTPUT ACTIVE PRE-ALARM or SOUNDERS SILENCED (configurable) POWER SYSTEM EARTH PLANT ALARM or O/P : / DISABLED (configurable) FIRE CONTROL O/P : / DISABLED FIRE OUTPUT : / DISABLED SOUNDER : / DISABLED POWER SUPPLY PRE- ALARM (Configurable) Individual FIRE and / DISABLED / TEST LED s per zone Membrane Push-button Controls RESET EXTEND DELAY MUTE BUZZER SILENCE / RESOUND END DELAYS / EVACUATE Configuration and Selection Keys 12-Key Numeric / Navigation Keypad,, and Navigation Arrows (Select) Push-button (Shift) Push-button for numeric functions (Access Code Prompt) Push-button LCD Display Alphanumeric 80 Character (2 x 40) Backlit Display SYSTEM CAPACITY Intelligent Signalling Line Circuits (SLC) 1 Loop per panel Number of Zones 16 Zones of Fire Detection per panel 16 Zones of Non-Fire (Plant Alarm) per panel Intelligent Sensors 99 Intelligent Sensors per loop Addressable Modules 99 Addressable Monitored / Control Modules per loop Page 5 of 6 990-052 Issue 6

MUTE BUZZER DISABLEMENT POWER ACCEPT EVACUATE NOTIFIER SILENCE RESOUND SOUNDERS SOUNDERS PRE-ALARM TEST DELAY ACTIVE SYSTEM COMMUNICATIONS LOSS RESET IDR-2A **** Notifier ID50 prototype 21.04.99 **** ZONE FIRE ZONE DISABLE/TEST DISABLEMENT TEST BUZZER MUTED PLANT ALARM DELAYED MODE RELAYS DISABLED POWER ID50 FIRE CONTROL PANEL Complies with EN54-2/4 1997 Period of Manufacture 1999 POWER SUPPLY EARTH SYSTEM SOUNDER SOUNDERS DISABLED SOUNDERS SILENCED 7 RESET MUTE BUZZER SILENCE/ RESOUND END DELAYS/ EVACUATE 4 6 1 0..9 8 2 0 9 3 DISABLEMENT POWER PRE-ALARM TEST DELAY ACTIVE SYSTEM COMMUNICATIONS LOSS 0 0 9 9 1 1 1 1 8 8 2 8 8 7 2 3 3 3 3 7 4 4 6 4 4 6 6 5 5 6 5 5 IDR-2P ID50 SERIES FIRE CONTROL SYSTEM IDR-2A Repeater Panel ID50 Series Panel IDR-2P Repeater Panel FIRE FIRE 5 Call Point 1 FIRE 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Optical Sensor Ionisation Sensor Heat Sensor Control Relay Output 2 11 10 9 8 7 6 5 4 3 2 1 211109 10 8 7 6 5 4 3 2 1 Door Holder (Externally Powered) Optical Sensor Duct Sensor A x10 B x1 C x10 0 0 9 9 x1 MULTI Sensor HARSH Sensor A B C 2 11 10 9 8 7 6 5 4 3 2 1 2 11 10 9 8 7 6 5 4 3 2 1 NOTIFIER Short Circuit Isolation Module Sounder Control Unit MODULE ACTIVE NOTIFIER Call Point Loop Powered Sounder Loop-powered Beam Detector Ionisation Sensor Conventional Detector Interface AVAX addressable Loop-powered Sounder Base Loop-powered Sounder/beacon Base and Sensor Conventional Detectors Page 6 of 6 990-052 Issue 6