ID50series. intelligent fire alarm panels

Similar documents
intelligent fire alarm ID60series panels

ID2000. intelligent fire alarm panel

ID3000 intelligent. fire alarm panel

ID3000 intelligent. fire alarm panel

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

ZXSe Range Data Sheet

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

DXc Control Panels. DXc1. DXc2. DXc4. Single Loop Control Panel, 230Vac, 2 sounder circuits. Dims 260 x 390 x 147mm (H x W x D)

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

Components Brochure DX CONNEXION

Product Data Sheet. Remote Terminals. Features:


HART XL High Sensitivity Smoke Detection

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

System 800 Addressable Fire Detection & Alarm System

HART XL High Sensitivity Smoke Detection

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Intelligent Single Loop Fire Alarm Control Panel

Intelligent 2 & 4 Loop Fire Alarm Control Panels

The EN54 Part 2, 4 and 13 Fire System

SMALL SCALE SOLUTIONS

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

DS7400Xi Addressable Control/ Communicator

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

Advanced FireAlarm Panel 1-4Loop

Intelligent Security & Fire Ltd

-Industrial. W hen All Else Fails... Difficult Applications. The Only TRULY Industrial Air Sampling Detector For Hostile and Difficult Environments

The EN54 Part 2 & 4 Fire System

Laptop / PC Programming Manual

Vigilant MX4428 Fire Alarm System

Product Catalogue. Intelligent Control Equipment for Life Safety. Issue 1

AFP-300/400 OPERATORS MANUAL INTELLIGENT FIRE DETECTION AND ALARM SYSTEM SOFTWARE VERSION 2.2 REVISION AUS 3

Discovery 4 Loop Analogue Addressable Control Panel (NVI & NVA series Protocols)

NETWORKING AND INTEGRATION

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide

ID2000. operating manual

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

Intelligent Earliest Warning Aspirating Fire Detector

Notifier by Honeywell: SMART Detection. SMART Detection. The Ultimate in False Alarm Technology...Make the SMART choice

user manual Document No , Revision 03 November 2015

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

GE Security EST Fire & Life Safety. Sophisticated io-series. Intelligent Life Safety Systems for small to mid-size buildings

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

Different types of Fire Alarm System

Addressable Fire Alarm Control Panel

Intelligent addressable fire alarm control panel

ACP10 & ACP50 Security Systems

Discovery 1-4 Loop 96 Zone, 40-Character Analogue Addressable Control Panel. Application Guide

Aspirated Smoke Detectors

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

Fire Control Panel FS5100

Consultant Specification AGILE Wireless Fire Detection System

Solution F1. Fire Control Panels the new generation

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Variable Frequency Drive SERIES MP800 VFD

Fire detection and alarm system Operating instructions

Input/Output Modules Data Sheet

GE Security Vigilant Fire & Life Safety. Easy. V-Series Intelligent Life Safety Systems

Solution F2. Fire Alarm Control Panels one step ahead.

SIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

LaserFOCUS VLF-250 Engineering Specification

Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology

ZM2 OPERATING AND MAINTENANCE INSTRUCTIONS

STANDARD TECHNICAL SPECIFICATION FOR AN ANALOGUE ADDRESSABLE FIRE DETECTION SYSTEM

Fire control panels FC360

TECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2

Document No Issue 4 user manual

Analogue Addressable Fire Panel Range

Across-the-Line SERIES MP300 Combined Manual and Automatic

Control Panel User Guide (TO BE RETAINED BY THE USER)

>WIRELESS> ALARM SYSTEM CR200

INTELLIGENT FIRE ALARM CONTROL PANEL

The supplier and installer of the system should be approved by the local civil defence authority.

Intelligent Security & Fire Ltd

Polycarbonate External Sounder & Strobe Unit

MX4428. Addressable Fire Alarm System. Features. Advantages & Options

The CWSI System CALL WITH QUESTIONS. RELY ON OUR KNOWLEDGE. DEPEND ON OUR EXPERIENCE. (800)

Document No Issue 02 operation & installation manual. ZXr-A ZXr-P

(68.52) X. June 2000 supersedes February vigilon ADVANCED FIRE DETECTION & ALARM SYSTEMS

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual

SPECIFICATION: AlarmLine TM INTELLIGENT LINEAR HEAT DETECTION

Fire control panels FC726 FC726-XA

MINERVA MX. 800 Series Ancillary Equipment

C E R T I F I C AT LPCB I O N B O A R D P R E V E N T L O S S. Cooper Fire Systems

Operating instructions SENTRI4 Control panel based Fire detection and alarm system

Air Sampling Smoke Detection

CONVENTIONAL FIRE CONTROL PANELS FS 5100 and FS 5200

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

Conventional Detectors

Sita200plus. 200detectors. Single loop analogue addressable System

ZSC100 Gas Detection and Alarm System Controller

Soft Start Series MP700 Solid State, Reduced Voltage

Addressable Fire Alarm Control System 2100 series

Transcription:

ID50series intelligent fire alarm panels

features LPCB approved to EN54 parts 2 and 4 One loop capacity (99 sensors and 99 modules) 16 fire zones, 16 non fire zones Supports NOTIFIER advanced range of advanced detection OptiPlex HARSH TM HAZARD TM 64 CBE rules Filter by device type Printer option Supports up to 72 hours backup Adjustable sensor sensitivity Automatic High Test Day / Night mode facility Time programs Class Change Autolearn facility One man walk test 2 x 40 character backlit LCD Active and passive repeaters Programmable from the panel keypad or PC Supports loop powered sounders Two on board sounder circuits Two on board configurable outputs Non-fire function support Introduction The NOTIFIER ID50 series single loop intelligent fire alarm panels, have been developed for both installers and end users with efficiency in mind, offering a technically advanced range of facilities and functions while remaining easy to install, program and operate. Three models are available in the ID50 series. The compact ID50, the ID51 with internal printer option and a larger separate power supply and the ID52 with internal printer option, a larger separate power supply and added space for 72 hours battery back up. A full range of intelligent sensors, advanced detection products, input and output devices, repeaters, mimic drivers and other peripherals complement the ID50 series to bring you the most complete and powerful single loop intelligent fire alarm panels in the market place. System The NOTIFIER ID50 series intelligent fire alarm panels are ideally suited for smaller system configurations such as schools, nursing homes, shopping units and offices. In more challenging environments such as stables, saw mills, food processing plants etc. detection is made possible by using the advanced range of sensors from NOTIFIER. The ID50 series provides control of 99 heat, smoke or multi-criteria sensors and a combination of 99 call points, monitor modules, control modules, conventional interface modules, loop powered beam detectors, sounders and relays on a single loop. In addition to the 16-zone fire/fault and 15 general status information LED s, the ID50 series have a 2 x 40 character, backlit LCD with variable viewing angle for easy reading. User-definable text messages can be read directly from the panel to provide details of fire and fault event locations. Advanced detection HARSH TM sensor (Hostile-Area Smoke Head) The HARSH sensor provides early warning detection in hostile environments where traditional smoke detectors are not practical. Using a small air fan and a highperformance replaceable filter, air and smoke are drawn into a photoelectric sensing chamber, while unwanted airborne particulate and water mist are

51109 Notifier 4/8/06 13:49 Page 5 The OptiPlex sensor from NOTIFIER combines superior optical smoke chamber design and thermistor heat elements with a sophisticated sensor algorithm to provide the next generation of multi sensors. Using advanced algorithms, OptiPlex continuously samples the environment and adjusts its sensitivity and alarm thresholds automatically to provide optimum removed. This feature allows HARSHTM to operate in difficult applications, such as textile, paper mills, and food processing plants, which due to environmental condition tend to cause nuisance alarms with standard smoke detectors. OptiPlex sensor (thermal & optical sensor in one) sensitivity for the conditions that exist at that time. Using both smoke and heat elements enable the sensor to respond quickly to a broad range of fire types whilst remaining unaffected by passing phenomena. This unique sensor, as well as utilising drift compensation, also provides two maintenance levels enabling preventative maintenance before the sensor reaches a maintenance-required level. Configuration The NOTIFIER ID50 series are selfcontained, on-site programmable, intelligent fire alarm panels. They can be programmed either from the panel keypad or from a personal computer using the off-line Windows -based configuration tool. An Auto-Learn facility allows the user to install and commission a Today s building environments are standard system with a minimum varied and often change. Public of effort. areas change from being occupied to empty, offices are cleaned thus producing dust to become airborne, a storeroom is storing plastics one day and cardboard another. These environments are normal and whilst wanting to provide a safe environment for the occupants, unwanted alarms are very undesirable. HAZARDTM sensor The panel software can be Many industrial environments are upgraded on site via a personal potentially explosive. Often, in computer using the NOTIFIER those environments, electronic flash-programming tool, making it equipment must be enclosed in very easy to update existing sites expensive, heavy, explosion-proof with the latest features. housings, which create a physical barrier between the electronics and the explosive environment. The HAZARDTM sensor from NOTIFIER provides a cost-effective alternative to explosion-proof fire detectors by providing an electronic barrier. HAZARDTM is specifically designed to operate with intrinsic safe barriers, which limit power to the hazardous area to safe levels.

The ID50 series software allows the system designer to group addressable sensors or modules into 16 zones. Output control actions may be grouped by alarm patterns and, if required, enable individual addresses to be activated by specific inputs or groups of inputs. This significantly simplifies configuration, reducing the time it takes to set up a complete system, and this allows actions in the event of fire to be customised using powerful input and output configurations to suit specific applications. Alternatively, the default mode can be used which gives the basic protection required by most safety standards to achieve a near instant functional system, suitable for emergency retrofit applications. System security and integrity is an important aspect of the ID50 series. An optional tamper switch can be installed to protect against unauthorised cover removal. Furthermore, user controls on the front panel are protected by up to 10 individually configurable passwords making it virtually impossible for unauthorised people to access the panel and its manual controls and change the system configuration. Alternatively, the key-switch can be used to enable/disable level 2 access. All configuration data is retained in non-volatile memory and is, therefore, protected against complete loss of the power supply. The models ID50 With A compact enclosure (380mm x 365mm x 110mm) and a single PCB with onboard power supply (1.5A), the ID50 provides the user with an easy to install/maintain Fire Alarm System. ID51 The ID51 is housed in a slightly larger enclosure (500mm x 400mm x 110mm) than the ID50 to accommodate for an internal mounted printer. A larger separate power supply (3A) is fitted in the ID51 to cater for the more power hungry applications. ID52 The ID52 is housed in a large enclosure (500mm x 620mm x 208mm) to accommodate for an internal mounted printer and space for up to 42AH batteries for 72 hours battery backup. A larger separate power supply (3A) is fitted in the ID52 to cater for the more power hungry applications and to provide enough power to support 72 hours of battery (42AH) backup should the mains AC power fail. Two front covers are provided on the ID52. One is fitted at the top part of the enclosure and one is fitted at the bottom part of the enclosure, thereby allowing for easy installation and maintenance of the panel, printer and batteries. Repeater and Mimic Driver The IDR Series repeaters and mimic drivers complement the ID Series intelligent fire alarm panels. By placing repeaters and/or graphical mimic display panels at strategic points in the facility such as nurse stations, floor landings, gatehouse or control rooms valuable time can be saved when identifying the location of a fire and/or evacuating the building. The IDR series repeater panels combine a compact design with a 2 x 40 character LCD. The LCD replicates the display on the ID50 series and uses the same, simple, menu-driven user interface. The control buttons and keys on the

repeaters enable the operator to navigate through the menu options and event displays. The nine LED indicators provide the user with a quick summary of the general system status. The repeater s compact design makes it very easy to install and commission in either surface mount or flush applications. The repeaters can store up to 150 most-recent events, therefore making commissioning very easy. Two models are available: a) IDR2A Active Repeater: Accept, Evacuate, Silence Sounders, Resound Sounders and Reset. The following, configuration and test functions are provided: Edit Normal message, Lamp Test, LCD Test and Buzzer Test. In addition to these standard test functions the IDR2A repeater has Power Diagnostics and a Push-button Test option. b) IDR2P Passive Repeater Mimic The mimic is a highly versatile product, which allows tremendous flexibility in configuring large numbers of system status LED s, relays and programmable digital inputs. Up to 16 mimics can be attached to the ID50 series via an RS485 communication link. Utilising the maximum capabilities of a full array of 16 mimics, 8192 LED or relay driven outputs, 896 high current outputs and 128 digital inputs are available. The IDR2A Active repeater will repeat the LCD & LED indications on the main fire alarm panel and allow the operator to command the system using system control pushbuttons such as Mute Buzzer, The IDR2P passive repeater is an indication-only repeater with no controls. The LCD and the common system status LED s follow the indication on the main fire alarm panel. The IDR2P has the same configuration and standard test functions as the IDR2A active repeater. Each mimic consists of a microprocessor based mimic control board and up to 8 flexible driver boards. Each driver board provides 64 LED or low current relay drivers, 8 high current driven outputs and 8 programmable digital inputs typically used for Mute, Lamp Test, Enable, Reset, Silence or other. Termination boards are also available to simplify wiring of LED s relays and other devices to each driver board

NOTIFIER international offices UK AUSTRALIA BENELUX BRAZIL CANADA CHILE CHINA GERMANY HONG KONG INDIA ITALY JORDAN LEBANON MEXICO POLAND SINGAPORE SOUTH AFRICA SPAIN SWEDEN USA VENEZUELA Charles Avenue Burgess Hill W. Sussex RH15 9UF T: +44 (0) 1444 230 300 F: +44 (0) 1444 230 888 E: sales@notifierfiresystems.co.uk www.notifierfiresystems.co.uk local distributor Every care has been taken in the preparation of this data sheet but no liability can be accepted for the use of the information therein. Design features may be changed or amended without prior notice. available only from your NOTIFIER Engineered System Distributor Ref: 573 (0206)