MAKING MODERN LIVING POSSIBLE. User Guide. Danfoss Air Units.

Similar documents
MAKING MODERN LIVING POSSIBLE. Installation Guide. Danfoss Air Units.

MAKING MODERN LIVING POSSIBLE. Danfoss Air Catalogue. Catalogue DANFOSS HEATING

Danfoss Air Heating Surfaces

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

Basic Plus2 Room Thermostats Floor Heating

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

User Manual HEAT RECOVERY VENTILATORS 1000 HE HE HE HE HE HE COMPACT 5585 COMPACT READ AND SAVE THESE INSTRUCTIONS.

READ AND SAVE THESE INSTRUCTIONS

VIGÖR HRV PLUS AND VIGÖR ERV

USER MANUAL. Portable Air Conditioner and Heater With Heat Pump Technology PAC18. Please read this manual carefully prior to operating the product.

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

HEAT RECOVERY VENTILATORS MODELS HRV 90H-V ECM, 90H-V

KSD-35 DR11 KUE-35 DVN11

Owner s Manual Super-Slim Four-Way Cassette

TPOne-B. Electronic Programmable Room Thermostat. Installation Guide. Danfoss Heating

MAKING MODERN LIVING POSSIBLE. User Guide. ECtemp 550. Electronic Intelligent Thermostat.

WARNING VL-220CZGV-E. 1. Safety Precautions LOSSNAY HEAT RECOVERY VENTILATOR (RESIDENTIAL USE) Contents. Eng-1. English

10L Dehumidifier. Model Number: LDH V AC 50/60Hz 290W

Sentinel Kinetic MVHR RANGE

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter

Modulating clock thermostat

Installation Guide. DEVIreg 535. Electronic Thermostat.

OWNER S MANUAL HIGH WALL INVERTER. (English) (MSHVD1S SERIES)

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N

Technical description. Atec.

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

PORTABLE AIR CONDITIONER

BRONZE MODELS 90H* 190H READ AND SAVE THESE INSTRUCTIONS

INSTRUCTIONS. Family 4 N 4062 Issue C Date 01/2011. CMV Certification reference NF205.

HEAT RECOVERY VENTILATORS MODELS AVS HRV EKO 1.5, AVS CONSTRUCTO 1.5V, NOVOFIT 1.0 AND ENERGY RECOVERY VENTILATOR MODEL AVS ERV EKO 1.

Register your product and get support at. AC4076. User manual

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h

20L Dehumidifier. Model Number: LDH V AC 50/60Hz 440W

CM921 - User Guide 1 day Wireless Programmable Room Thermostat with LoT technology

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

Diplomat Inverter/Diplomat Duo Inverter

USER GUIDE MODELS ERV CONSTRUCTO 1.5 QUATTRO ERV CONSTRUCTO 2.0 QUATTRO READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY rev.

Register your product and get support at AC4002 AC4004. User manual

USER GUIDE HEAT RECOVERY VENTILATORS MODELS HRV 90H-V ECM, 90H-V AND 60H NOVO+, MODEL ERV 90H-V ECM PLEASE READ AND SAVE THESE INSTRUCTIONS

AUS. Devireg TM 535 Installation and user manual

OWNER S MANUAL KPD-105 DTN11 KPD-140 DVN11 KPD-140 DTN11 KPD-160 DTN11 KPD-52 DVR11

OWNER S MANUAL HIGH WALL INVERTER. (English) (BSHVD1S SERIES)

PORTABLE AIR CONDITIONER

GB-DAS. Installation and user manual DEVIreg 850 controller

User Guide. itec.

Using the Remote Control Unit

User instructions DHP-AT

DAIKIN ROOM AIR CONDITIONER. Operation Manual

PRODUCT DATA COMPACT S BY NILAN. Sanitary hot water production. Passive heat recovery. Comfort heating. Ventilation < 375 m 3 /h. Active heat recovery

PAC12J. 12,000btu Cool & Heat Portable Air Conditioner. Please read this manual carefully prior to operating the product.

Vallox INSTRUCTIONS FOR USE AND MAINTENANCE. Compact. Supply and extract air ventilation with heat recovery

Register your product and get support at. AC4006. User manual

ECO AND DATE /06 ARTWORK DESCRIPTION. 22 page A6 : Saddle stitch (2-wire) 6 page : 4 colour : 170gsm Silk 18 page : 1 colour : 100gsm Silk

User manual AG-WT10. Indoor unit air/air heat pump UHB GB

Installation and user manual

VK-6008D. User Manual

TYBOX PAC. * _rev1* User guide. Programmable thermostat for heat pumps

Owner s Manual TABLE OF CONTENTS

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For models WA-1010E, WA-1010H, WA-1010M

Operation manual. Split system air conditioners FDXM25F3V1B FDXM35F3V1B FDXM50F3V1B FDXM60F3V1B. Operation manual Split system air conditioners

SmartDial. Wireless. User Manual. -en_gb language A004. Document in original

DEVIreg Opti Electronic Timer Thermostat fulfilling Eco Design Directive

Weather compensated flow temperature control of heating and boiler systems

User manual AG-WT10. Indoor unit air/air heat pump UHB GB LEK

Climapro 2. User manual. wireless room thermostat without receiver. To be left with the user.

MAKING MODERN LIVING POSSIBLE. Installation Guide. ECtemp 550. Electronic Intelligent Thermostat.

User manual. Always there to help you. Question? Contact Philips AC3252 AC3254 AC3256

EFET 535. Installation Manual INT INT

Portable Air Conditioner, Dehumidifier,Heater and Fan utilizing Heat Pump Technology

SAVE VTR 250/B. User Manual. Document in original language A001

SLIDER CASEMENT AIR CONDITIONER

living connect, Electronic Radiator Thermostat

UNIT MODEL/ POWER SUPPLY VOLTAGE VARIATION AMBIENT AIR ON CONDENSER

Product waste disposal - Protection of the environment:

Owner s Manual STAINLESS CONICAL CHIMNEY HOOD CONTENTS

Heat Recovery Ventilation Systems OWNER S GUIDE

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

MAKING MODERN LIVING POSSIBLE. Wiring Diagram. DHP-iQ.

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

CTS 602 by Nilan. Compact P. Compact P Sun. Compact P Cool. Compact P Cool Sun. Version: 5.00, Software-version: 2.11

PAC12H. 12,000btu Cool & Heat Portable Air Conditioner. Please read this manual carefully prior to operating the product.

SAVE VTC 700. Heat Recovery Ventilation Unit

OPERATION MANUAL. System Inverter Air Conditioners FXNQ20A2VEB FXNQ25A2VEB FXNQ32A2VEB FXNQ40A2VEB FXNQ50A2VEB FXNQ63A2VEB

SonoSelect and SonoSafe energy meters

Installation Guide. DEVIreg 534. Electronic Thermostat.

installation and operating instructions K224 rangehood

Instruction manual. Remote control electric IR HEATER

User Manual THR870CUK Programmable Thermostat

Capacity controller for water chiller AK-CH 650

Freemove Air.

P O R T A B L E Air Conditioner

Maintenance Matters. Maintaining Your Heat Recovery Ventilation System

USER MANUAL. OPTIMA 312 ES960C circuit board

Alarm System SECURE AS 302

Transcription:

MAKING MODERN LIVING POSSIBLE User Guide www.heating.danfoss.com

The English language is used for the original instructions. Other languages are a translation of the original instructions. (Directive 2006/42/EC) 2012 Copyright Danfoss A/S

Table of Contents 1 Introduction............................................. 3 2 Main Menu.............................................. 4 3 Menu Structure........................................... 6 4 Settings................................................ 7 5 Replacing Filters.......................................... 10 6 Replacing Air Dial Batteries.................................... 11 7 Cleaning the Air Unit........................................ 11 8 Heating Surfaces.......................................... 13 9 PC Controls.............................................. 15 10 Troubleshooting.......................................... 15 1 Introduction Congratulations on buying a Danfoss Air Unit The are among the most advanced, efficient, quiet and easy-to-use heat recovery ventilation systems. With the Air Dial you have the entire system under control, simply by turning and pushing one dial, while all necessary information is shown in the display. With this User Guide we wish to take you through the few steps needed to operate and to maintain your system. Danfoss Air Unit Air Dial Power supply CCM module All Danfoss Air units are Passive House certified by The Passive House Institute in Darmstadt. The Danfoss Air system uses Z-Wave wireless technology. Find more information on our website www.air.danfoss.com on the possibilities with Danfoss Air and Z-Wave technology. Danfoss Heating Solutions VUEWA702 3

2 Main Menu Main menu > Boost The manual Boost command is used when larger air flow than normal is required, e.g. when cooking something with a strong odour or when someone is smoking. As default the Boost function makes the unit run at full speed for 3 hours, but these parameters can be changed in the Settings Menu. The Autoboost function automatically increases the air flow, if humidity suddenly increases (e.g. caused by bathing or cooking). The Autoboost is active for 30 minutes, whereafter the system returns to the original air flow. The Autoboost function is switched on or off in the Settings menu. Main menu > Away The Away command is used to reduce the air flow to a minimum, e.g. when you leave the house for a longer period of time. The unit will automatically return to normal operation, when the Away period is over. Parameters for the Away period are set in the Settings menu. Note: If a heating surface is installed, it is turned off during the Away mode (saving energy). Main menu > Bypass (not available for w¹ units) The Bypass is a cooling function, which uses the heat exchanger for lowering the supply air temperature. When the Bypass is open, outdoor air is led directly into the house. The Bypass can be activated in two ways: 1. Manually, by pressing the Bypass command. This will start the Bypass function for 3 hours (run time can be changed in the Settings menu). The Bypass will not be activated if the outdoor temperature is below +5 C. 2. Automatically, if both outdoor air temperature and room temperature are above the level selected in the Settings menu. The Bypass automatically closes, when one of the temperatures is below the selected level. The automatic Bypass function is switched On or Off in the Settings menu. Cooling Recovery function is an automatic system feature with Auto Bypass activated. If the outdoor temperature rises above the indoor temperature, the Danfoss Air unit can automatically close the Bypass and use the heat exchanger as a cooling application to lower the supply temperature a few degrees. When Cooling Recovery is activated, the Bypass icon is Off. Main menu > Info The info command shows a list with the present status of the unit: all measured temperatures, fan steps, relative humidity in the room and much more... 4 VUEWA702 Danfoss Heating Solutions

Main menu > Mode With the Mode command you can choose how the Danfoss Air system is controlled: Mode > Off In the event of a toxic spill or fire outside the building, the unit can be turned off. After 24 hours, it starts up on step 1 of 10 to prevent moisture accumulation in the building. Thereafter the user can change the run mode if needed. Mode > Manual In Manual mode the air flow is kept constantly at the selected level (fan step 1 to 10). Bypass and Autoboost are automatically controlled, but can be switched off in the Settings menu. Mode > Demand In Demand mode the built-in humidity sensor ensures that the air flow is automatically regulated: if the relative air humidity is too low inside the house, the system reduces the air flow. if the relative air humidity is too high, the system will work with a larger air flow. Note: Outside the heating season the air flow will remain more or less constant at a rate equivalent to the basic step settings. This ensures maximum comfort at the time of year where heat loss is negligible. % Mode > Programme In Programme mode one of five pre-defined family profile is chosen. Based on the profile, ventilation rate is high during the periods when the house is occupied and less when the house is empty. Periods of increased air flow when bathing or cooking takes place are included in the programmes. If none of the pre-defined profiles suits your requirements, you can download a pctool (freeware) with the option of creating your own user profile. Find the download and installation manual at www.air.danfoss.com. If you choose Programme mode with no further settings, thee default profile is no. 1. PROG Danfoss Heating Solutions VUEWA702 5

3 Menu Structure Main menu Back Boost Away Bypass Info Mode Settings On / Off Activates manual boost for a limited time On / Off On / Off Reduces air volume to an absolute minimum inside a defined interval Activates manual bypass for a limited time Back Program Bypass Boost Time & Date Night cooling Restore defaults On / Off Fireplace opt. Back Factory settings: No Yes Set Back Boost duration: 3 hours Auto boost: On / Off Max. boost step: 10 / 10 Back Bypass (if room temp.): >22 C and >16 C Bypass duration: 3 hours Auto bypass: On / Off Back Profile 1 Profile 2 Profile 3 Profile 4 Profile 5 Back Demand Program Manual Off Back Actual step Humidity Filter remain Temperatures Accessories Show runtime Basic step Alarm status Alarm log SW & unit ID 6 VUEWA702 Danfoss Heating Solutions

Note: The "Bypass" options and functions are not available for the "w1" unit. 4 Settings Main menu > Settings > Program > Profile 1-5 Before choosing a pre-defined program, the Program menu must be activated. Go to Main menu > Mode and choose Program. Then you can choose between 5 different pre-programmed profiles, as shown below Or create your own custom profile with Danfoss PC Tool, which can be downloaded from www.air.danfoss.com (freeware). A custom profile will be visible in the menu as Main menu > Settings > Program > Profile > User defined. Profile 1: Family with children, both adults working normal hours. Fan (% of basis step) Fan (% of basis step) Weekdays Weekends Profile 2: Family with children, one working adult, normal working hours, one adult at home during the day. Fan (% of basis step) Fan (% of basis step) Weekdays Weekends Profile 3: Couple without children, both working adults, normal working hours. Fan (% of basis step) Fan (% of basis step) Danfoss Heating Solutions VUEWA702 7

Weekdays Weekends Profile 4: Single person (working adult), no one at home during work hours. Fan (% of basis step) Fan (% of basis step) Weekdays Weekends Profile 5: Small commercially used office or sales outlet area. Opening times 8 am-4 pm, closed at weekends. Fan (% of basis step) Fan (% of basis step) Weekdays Weekends Main menu > Settings > Bypass Set parameters for the automatic Bypass (outdoor temperature and room temperature). The automatic Bypass function is activated, when both outdoor air temperature and room temperature are above the selected parameters. If only one of the parameters is present, the automatic Bypass is not activated. To start the Bypass manually, press the Bypass command. The Bypass is active in the time period chosen in Main menu > Settings > Bypass > Timer (default setting is 3 hours). The Bypass will not be activated if the outdoor temperature is below +5 C. Note: Bypass options and functions are not available for the "w1" unit. Main menu > Settings > Boost Customise the Boost function to match individual requirements: 8 VUEWA702 Danfoss Heating Solutions

Set timer for manual Boost (default is 3 hours) Turn Autoboost On or Off. When Autoboost is On, it is active in all modes. Reduce maximum Boost step, if the default maximum step (10 = 100% fan speed) is too powerful for the system. Main menu > Settings > Time & date Set the actual time and date of the system. Main menu > Settings > Night cooling Turns the Night Cooling function On or Off (default setting is Off). With Night Cooling on the system automatically detects if it was a warm day (the outdoor air temperature is over 20 C at noon and at 4 PM). If so, the fresh, cool outdoor air is led directly to the supply air from midnight until 6 AM. The Night cooling function automatically stops if the outdoor air temperature falls below 10 C or if the extract air temperature falls below 18 C. Note: Night Cooling is not available for the "w1" unit. Main menu > Settings > Restore default Restore all user settings to factory default values. Main menu > Settings > Fireplace opt. Turns the Fireplace opt. On or Off. If a fireplace is present, the Fireplace opt. can prevent the creation of unwanted negative pressure, which can cause severe problems to humans and animals. With the Fireplace opt. On the Danfoss Air system monitors the temperature values continuously, preventing the unit from entering the automatic Defrost mode (in Defrost mode the unit de-ices the heat exchanger in periods with very low outdoor temperatures). If the temperature ratios demands a Defrost mode, the unit's automatic safety function immediately stops both fans for 30 minutes, then slowly starts again and checks the temperatures. If temperatures are OK the unit returns to normal operation, if temperatures are not OK the unit re-enter the safety function and stops for an additional 30 minutes. To avoid problems with negative pressure Danfoss recommends to install a pre-heating surface with the Danfoss Air unit (see chapter 8). Adjustment of the Danfoss Air unit When you are going to commission your unit for the first time or if you want to install a fireplace after some time, we recommend you to adjust both supply and distract air to be equal. Hereby you secure a "balanced" airflow. A too large supply air rate can cause an overpressure in the building. This must be avoided at any means due to an unwanted accumulation of humidity in the building. Legislative conditions The installation of a Danfoss Air system must always comply with all national, regional or local legislations and rules. Danfoss Heating Solutions VUEWA702 9

Important! Most homes include household appliances (cooker hood, dryer, central vacuum cleaner etc.), which can create negative pressure by removing air volume. It is important to check for these appliances and ensure that they will not affect the Danfoss Air system or the fireplace. Example Cooker hood with recirculation. The air volume is returned to the room after cleaning. This will not affect the Danfoss Air system or the fireplace. Cooker hood with direct exhaust. The air volume is removed from the room. This creates negative pressure, which will affect both the functionality of the Danfoss Air system and the combustion process of the fireplace, if there is no substitution of the air. If you experience any problems with negative pressure, contact you installer. 5 Replacing Filters Danfoss Air units are designed for an absolute minimum of maintenance. Maintenance is limited to one or two filter replacements a year, depending on air volume and local air pollution level. In industrial areas and in areas with a high concentration of pollen in the outdoor air the filters will be clogged faster than in a typical suburban environment. Danfoss Air units are fitted with original filters that are designed to protect the unit and the indoor climate. These filters have been tested and validated, so that they also protect the internal components like heat exchanger and fans. If other filters than the original spare parts are used, Danfoss cannot guarantee the full quality or lifetime for the internal components. Standard filters and optional pollen filters (F7 class) can be purchased from your installer. Replace filters when Air Dial gives the filter alarm (alarm sound from and message in display): 1. Remove the front panel (no tools needed). 2. Pull out the filters and inspect them visually. 3. If the filter is only lightly fouled/discoloured, you might try to clean it, using a vacuum cleaner with a brush. Normally this will not be worthwhile nor recommended. 4. Fit new filters* and reattach the foam covers. 5. Press the filter reset button on the front of the unit. * If you have bought a special pollen filter, it should be fitted in the filter slot to the right (on all models), as this is filtering the outdoor air. 10 VUEWA702 Danfoss Heating Solutions

User Guide Standard filter set The standard filter set are G4 class for both supply and discharge air, which provide basic filtration of particles larger than 10 μm. Order no. G4/G4 standard filter set for Danfoss Air Unit w¹ 089F0238 G4/G4 standard filter set for Danfoss Ait Unit w² 089F0239 G4/G4 standard filter set for Danfoss Air Unit a² 089F0236 G4/G4 standard filter set for Danfoss Air Unit a³ 089F0237 Pollen filter set If allergies are present in your family, choose a pollen filter set with F7 class filter for supply air to effectively filter out pollen. Order no. G4/F7 pollen filter set for Danfoss Air Unit w¹ 089F0242 G4/F7 pollen filter set for Danfoss Ait Unit w² 089F0243 G4/F7 pollen filter set for Danfoss Air Unit a² 089F0240 G4/F7 pollen filter set for Danfoss Air Unit a³ 089F0241 6 Replacing Air Dial Batteries When the Air Dial needs a new set of batteries it is indicated by an alarm sound. Lift the Air Dial off the wall bracket and replace with four AAA batteries. 2 1 7 Cleaning the Air Unit The inside of the Danfoss air unit should be cleaned every other year. 1. Disconnect power and remove the front panel. Danfoss Heating Solutions VUEWA702 11

User Guide 12 2. Remove the six screws holding the three metal rails (using the correct size torx key). 3. Remove the front foam panel to get access to the parts inside the unit. 4. Pull the thick round seal over the heat exchanger out sideways. When remounting the exchanger, the round seal should be inserted last. This is best done by locking in the two ends first and then pushing the rest of the seal into place. 5. The heat exchanger can now be lifted/pulled carefully out of the core. VUEWA702 Danfoss Heating Solutions

6. Pour a mild solution of regular dishwashing soap through the four open sides of the heat exchanger. Let it soak for 5-10 minutes before rinsing under running water. Dry the exterior of the heat exchanger, and gently slide the heat exchanger back into the unit. Clean interior surfaces of the unit with a wet sponge or cloth (use a mild soapy solution). Under no circumstances use solvents for cleaning the foam parts, as solvents can dissolve the special foam material. Avoid spraying water onto the main circuit board. If water is spilled onto the board, tap it lightly with a dry cloth and leave to air dry for min. 24 hours before reconnecting the power. Assemble the unit in reverse order: 1. Install the foam front panel. 2. secure the panel with the three metal rails. 3. Tighten torx screws. 4. Reinstall the front panel. You are now ready for another two years of trouble-free operation. 8 Heating Surfaces A pre-heating surface gives a large range of benefits for the Danfoss Air system and the indoor climate in general. Danfoss always recommends to install a pre-heating surface with the Danfoss Air unit. With a pre-heating surface the system is protected against entering the automatic Defrost mode, which can cause negative pressure in the building - especially if a fireplace is present. Preheating surface, electric 3 2 4 + 1 1. Outdoor air 2. Supply 3. Extract 4. Exhaust The electric preheating surface is used to protect the system against icing up at low outdoor temperatures. Before the outside air reaches the system, it is heated up from the current outside temperature to 0 C (which makes frost formation in the exchanger impossible). This solution ensures a permanent balance between the supply and extraction air. Adjustment is 100% stepless to ensure the lowest possible power consumption during operation. No settings are required on an electric preheating surface. Danfoss Heating Solutions VUEWA702 13

Afterheating surface, electric 2 + 3 1 4 1. Outdoor air 2. Supply 3. Extract 4. Exhaust The electric afterheating surface is used to ensure a minimum supply temperature before the air is blown into the room. The ventilation system will usually heat the outside air up to a temperature that is very close to room temperature so the electric afterheating surface is only used to give the supply temperature a little lift. Adjustment is 100% stepless to ensure the lowest possible power consumption during operation. The required supply temperature can be set from the Air Dial in Main menu > Settings > Temperature > Supply. Afterheating surface, water-based 2 + 3 5 6 1 4 1. Outdoor air 2. Supply 3. Extract 4. Exhaust 5. Pump 6. Central heating The water-based afterheating surface is (most often) used to ensure a minimum supply temperature before the air is blown into the room. The ventilation system will usually heat the outdoor air up to a temperature that is close to room temperature so the water-based afterheating surface is only used to give the supply temperature a little lift. 100% stepless control is carried out via the built-in motor valve. The required supply temperature can be set from the Air Dial in Main menu > Settings > Temperature > Supply. The afterheating surface can also in special cases be used as total heating in passive or 0 energy houses if all parts of the system have been dimensioned for it. If your system was configured for air heating, the room temperature can be set in the main menu. 14 VUEWA702 Danfoss Heating Solutions

Preheating/cooling surface, geothermal 3 1 2 4 5 1. Outdoor air 2. Supply 3. Extract 4. Exhaust 5. Pump The geothermal surface is able either to preheat or precool the outside air depending on the season. The control automatically determines what is required and controls the surface in and out of operation as required. The geothermal surface is provided with anti-freeze (brine) which is circulated in a buried ground pipe using a circulation pump. This means that it is free renewable energy that can be used with a clean conscience. In the winter, preheat can be used to prevent the system from going into frost protection mode and in the summer it can provide pleasant additional cooling by cooling the air before it reaches the system. When the geothermal surface is cooling, the ventilation system s bypass of course opens automatically. 9 PC Controls Control your DANFOSS AIR system from your PC screen via Ethernet. Make customised weekly programmes with the user-friendly week programme editor. Monitors and displays all temperatures and relative humidity in the house, in a single screenshot See trend curves for the last 14 days, all relevant sensors are logged hourly Easy access to advanced settings, all functions are described in a short and easy to understand text. Download Danfoss Air PC Tool from www.air.danfoss.com - it is free of charge! 10 Troubleshooting Error Cause Solution Alarm:Filter error Air filters are dirty. Exchange air filters. Alarm: Battery low Battery voltage in Air Dial is too low. Replace batteries (4 x AAA) in Air Dial. Alarm: No connection to CCM Communication between Air Dial and CCM module has failed, typically caused by an obstacle between Air Dial and CCM module, e.g. steel piping, other steel objects, insulation material clad with aluminum foil, etc. Another cause can be other wireless appliances that does not conform to wireless standards (radio noise). If an obstacle has been identified, move it. If this is not possible, move CCM module to a better location with a free line of sight. If the error occurs due to other wireless appliances in your house, try switching these off in turn to identify the faulty device. If none of the above helps, please contact your installer. Danfoss Heating Solutions VUEWA702 15

Alarm: No connection via modbus Alarm: Room air too cold Alarm: Fire Alarm: Sensor error Alarm: Supply air too cold Alarm: Fireplace stop activated Abnormally large negative pressure inside the house, doors binding Cable between CCM module and unit is unplugged or defective. Central heating system is not supplying heat. Room temperature is dropping, so the unit turn off to reduce involuntary heat loss. Alarm active if Air Dial measures a room temperature below +10 C. One of four temperature sensors in Danfoss Air unit or temperature sensor in Air Dial remote control has detected a temperature higher than +70 C. Unit turns off until all sensors indicate < +70 C. Temperature sensor in Danfoss Air unit or Air Dial is defective. The supply air sensor has detected a supply temperature below +5 C and the unit automatically stops to prevent unwanted cooling of the building. This detection is caused by negative pressure due to an external influence, e.g. a cooker hood with direct exhaust. With Fireplace opt. activated: the unit has stopped due to a risk of a negative pressure. Discharge air flow is larger than supply air flow. Either balancing was not carried out correctly during set-up of the system or unit is in extreme defrost conditions (can occur at outdoor temperatures < -12 C). Check cable and reconnect if necessary. If cable is connected, but error still occurs - contact installer. Check if heating system is functional. If the problem can not be solved, contact plumber/installer. When error has been remedied, shut down and restart ventilation system to resume normal operation. Power can be disconnected by pulling power cable from system. Examine all rooms, leave the house. When error has been remedied, shut down and restart ventilation system to resume normal operation. Power can be disconnected by pulling power cable from system. Contact installer. System continues to run, but with limited functionality. Power cycle the unit to start it again. Investigate which household appliance is the cause of the alarm. Danfoss recommends installing a pre-heating surface or/and using household components with air recirculation. For further details contact your installer. The unit stops for 30 minutes, then all temperatures are checked. If temperatures are OK the units starts again. If not the unit will cycle this process continuously until all temperatures are in the right range. A permanent solution could be installing a pre-heating surface. Contact your installer for further details. Imbalance of flow should be 4-10% in favour of discharge air, but if problems with doors binding is permanent, contact installer. If problems only arises during extreme winter condition, it is due to the integrated defrost controller that reduces the supply air (hence not a defect, but an expected, and very rare occurrence). 16 VUEWA702 Danfoss Heating Solutions

Condensation in window frames House temperatures are too high Noise from unit Noise from Air valves Frost icon in display Air exchange is too low. Condensation occurs when humidity is high and surface temperatures are low, typically in bathrooms or utility rooms, where clothes are drip drying (some condensation in bathrooms following a shower is normal, but should disappear within half an hour). House thermostats are set too high. Increase fan step (Manual mode) or change to Demand mode or Programme mode. Set Autoboost. on. Turn down thermostats. Bypass is disabled on ventilation system. Enable Bypass in Main menu > Bypass > Auto bypass. a-type unit: vibration noise may occur if unit is mounted directly onto joists. Unit should be mounted on a suitable platform. w-type unit: vibration noise may occur if rubber spacers are not fitted between unit and wall and/or if silicone strip is not fitted onto wall bracket. Defective fan bearings will produce a grinding noise. Air flow is too high. Pressure is too high over valve. No silencer is fitted to main duct. The system is in defrost mode, because low outdoor temperatures entail a risk of ice forming in the heat exchanger. Check that unit is mounted on platform, according to installation manual. Check that rubber spacers and silicone strip are fitted, according to installation manual. If fan ball bearing is suspected to be defective, contact installer. Noise is not a problem in a correctly sized and commissioned system. However, if air valves are closed (e.g. during cleaning), a hissing noise may occur. This is not an error, but a standard mode. The function stops automatically when the outdoor temperature rises. Danfoss Heating Solutions VUEWA702 17

18 VUEWA702 Danfoss Heating Solutions

Danfoss Heating Solutions VUEWA702 19

Danfoss A/S Heating Solutions Ulvehavevej 61 7100 Vejle Denmark Phone:+45 7488 8500 Fax: +45 7488 8501 Email: heating.solutions@danfoss.com www.heating.danfoss.com Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss Heating Solutions and the Danfoss Heating Solutions logotype are trademarks of Danfoss A/S. All rights reserved. VUEWA702 Produced by Danfoss Heating Solutions 08/2012