CO2MSZ Carbon Dioxide Gas Monitor Single Zone

Similar documents
PGM-IR Halogen Monitor Bagless Portable Gas Monitor for Halogen Gases (Refrigerants)

HGM-RD Remote Display Module: Refrigerant Gas Monitoring System

HGM-RD Remote Display Module for Refrigerant Gas Monitoring System

MZ-RD Remote Display. Instruction Installation / Operation / Maintenance. Rev. 6 December 2011

PGM-IR Halogen Monitor

Portable area gas monitor with infrared sensor for halogen

HGM-MZ Halogen Gas Monitor Multi Zone

PGM-IR CO 2 Monitor. Instruction Operation and Maintenance. Portable Gas Monitor for Carbon Dioxide (CO 2 ) Gas. Rev.

Rev 4 12-APR IRLDS II and IRLDS II User Interface Installation and Operation Manual

Gas Monitor Multi Zone

SECTION 1 (Page 2) Introduction, standard accessories and mounting specifications.

HGM300/RDM800 PREVENTATIVE MAINTENANCE AND TECHNICAL SUPPORT. SECTION 1 HGM300 CPU reset, RDM800 CPU reset, WARM UP notes and HGM300 Self Test

SAFETY INFORMATION AND WARNINGS

Controllers. Instruction Manual WARNING

GG-R REFRIGERANT SENSOR. Installation and Operation Manual

Remote Relay Module (RRM)

Instruction Manual WARNING

GG-NO2 NITROGEN DIOXIDE GAS SENSOR. Installation and Operation Manual

Installation, Operation & Service Manual

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

Alnor AirGard 410HE Air Flow Monitor for Hazardous Environment Fume Hoods

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

Beacon 800 Gas Monitor Operator s Manual

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

Figure 1. Figure 2. See notes 1 and 2 below.

GG-H2S HYDROGEN SULFIDE GAS SENSOR. Installation and Operation Manual

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

SEC 2000 Millenium Infrared Gas Detector

Installation and Operations Manual

GASGUARD H2S EXP. Hydrogen Sulfide Sensor OPERATING & INSTALLATION MANUAL

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

SEC Signature Process Gas Analyzer

GASGUARD SO2 Sulfur Dioxide Sensor OPERATING & INSTALLATION MANUAL

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

KM300 Carbon Monoxide Detection System Installation Manual

Document No

Warranty Registration

GG-CO-EXP CARBON MONOXIDE SENSOR. Installation and Operation Manual

Oxygen Monitor Operating Manual

CO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

FLCH4R Garage and Utility Electric Heater

GG-NH3 AMMONIA GAS SENSOR. Installation and Operation Manual

GG-NH3-2% AMMONIA GAS SENSOR. Installation and Operation Manual

Carbon Dioxide Sample-Draw Detector Operator s Manual

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL

RK Carbon Monoxide Transmitter Operator s Manual

IT COULD FAIL TO PERFORM AS DESIGNED AND PERSONS WHO RELY ON THIS PRODUCT FOR THEIR SAFETY COULD SUSTAIN SEVERE PERSONAL INJURY OR DEATH.

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model 120VC Single Relay (100/25 PPM) (200/35 PPM)

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

RK/ RK Carbon Monoxide Detector Operator s Manual

Refrigerant / Combustibles Leak Detector

AMC-RAM-4. Refrigerant Alarm Module USER MANUAL. Please read the installation and operating instructions completely and carefully before starting.

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Model 405 AIRGARD Fume Hood Monitor

Introduction... 1 System Overview... 1 System Diagram... 2

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

RK CO 2 Transmitter Operator s Manual

Beacon 410A Gas Monitor Operator s Manual

CO2 Monitor Operating Instructions

Interrupted Ignition Series Oil Primary Control

Duct and Rough Service Carbon Monoxide Sensor

RK-05 Carbon Monoxide Detector Operator s Manual

OWNERS MANUAL. CARBON MONOXIDE DETECTOR MODELS Panel Mount & Remote Detectors (R) Guardian Avionics 1951 E. AIRPORT DRIVE TUCSON, AZ.

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Beacon 110 Gas Monitor Operator s Manual

High Performance Oilless Residential Light Commercial. Product Leadership Training Service Reliability

GAS MONITOR Model Model

User Manual. Humidity-Temperature Chart Recorder. Model RH520

RK / RK Methane Detector Operator s Manual

Static Pressure Alarm For Hazardous Location Fume Hoods

Manual No: Revision: E. Groundwater Sensor. Installation Guide

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 715

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

GG-VL-R REFRIGERANT VENT LINE SENSOR. Installation and Operation Manual

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

APC BC300 Series 40kW 208/450/480V User Guide

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

Humidity Monitor model 01080

Falcon-II Next Generation, Air Quality Monitor CO2 & Temperature

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model COSTAR 24VC-e Single Relay

GG-LEL2 COMBUSTIBLE GAS SENSOR. Installation and Operation Manual

Macurco HD-11 Hydrogen Gas Detector

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

GLD-30 Gas Leak Detector

MODEL QTS-1800 SERIES WALL MOUNT DIGITAL AND ANALOG TRANSMITTER/SENSOR

Operation and Maintenance

RK-02 Multi Point Detector Operator s Manual

Transcription:

CO2MSZ Carbon Dioxide Gas Monitor Single Zone Instruction 3015-4603 Installation / Operation / Maintenance Rev 2 - August 2009 Product Leadership Training Service Reliability

WARRANTY Bacharach, Inc. warrants to Buyer that at the time of delivery this Product will be free from defects in material and manufacture and will conform substantially to Bacharach Inc.'s applicable specifications. Bacharach's liability and Buyer's remedy under this warranty are limited to the repair or replacement, at Bacharach's option, of this Product or parts thereof returned to Seller at the factory of manufacture and shown to Bacharach Inc.'s reasonable satisfaction to have been defective; provided that written notice of the defect shall have been given by Buyer to Bacharach Inc. within two (2) years after the date of delivery of this Product by Bacharach, Inc. Bacharach, Inc. warrants to Buyer that it will convey good title to this Product. Bacharach's liability and Buyer's remedy under this warranty of title are limited to the removal of any title defects or, at the election of Bacharach, to the replacement of this Product or parts thereof that are defective in title. The warranty set forth in paragraph 1 does not apply to parts the Operating Instructions designate as having a limited shelflife or as being expended in normal use (e.g., filters). THE FOREGOING WARRANTIES ARE EXCLUSIVE AND ARE GIVEN AND ACCEPTED IN LIEU OF (I) ANY AND ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE: AND (II) ANY OBLIGATION, LIABILITY, RIGHT, CLAIM OR REMEDY IN CONTRACT OR TORT, WHETHER OR NOT ARISING FROM BACHARACH'S NEGLIGENCE, ACTUAL OR IMPLIED. The remedies of the Buyer shall be limited to those provided herein to the exclusion of any and all other remedies including, without limitation incidental or consequential damages. No agreement varying or extending the foregoing warranties, remedies or this limitation will be binding upon Bacharach, Inc. unless in writing, signed by a duly authorized officer of Bacharach. Register Your Warranty by Visiting www.mybacharach.com Declaration of Conformity Manufacturer s name: Manufacturer s address: Product Name: Bacharach, Inc. 621 Hunt Valley Circle New Kensington, PA 15068 CO2MSZ (Carbon Dioxide Gas Monitor Single Zone) conforms to the following harmonized European EMC standards: EN61326-1 EN61000 EN55022 Notice: Product improvements and enhancements are continuous; therefore the specifications and information contained in this document may change without notice. Bacharach, Inc. shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. No part of this document may be photocopied, reproduced, or translated to another language without the prior written consent of Bacharach, Inc. Copyright 2009, Bacharach, Inc., all rights reserved. BACHARACH is a registered trademark of Bacharach, Inc. All other trademarks, trade names, service marks and logos referenced herein belong to their respective owners. A Instruction 3015-4603

Table of Contents INTRODUCTION... 1 How To Use This Manual...1 Warning Statements...1 Caution Statements...1 Hazard Symbols on Monitor...1 Safety Precautions...2 AC Power Supply...2 Protective Grounding...2 Explosive Atmosphere...2 Proper Exhaust Venting...2 Working Inside the Monitor...2 Misuse and Modifications to Monitor...2 In Case of Malfunction...2 Fusing...2 Installation Category...2 Altitude Limit...2 Cleaning...2 Functional Overview...3 General Description...3 Understanding Monitoring levels...3 Suggested Location of Sampling Points...4 INSTALLATION... 5 Installation Considerations...5 Warnings and Cautions...5 Inspection...5 Locating the Monitor...5 Mounting Instructions...6 Connecting Gas Sample, Purge, and Exhaust Lines...6 Overview...6 Tubing Considerations...7 Connecting the Gas-Sample Line...7 Connecting the Purge Line...7 Connecting the Exhaust Line...7 Interior Schematic...8 Electrical Wiring...9 Connecting External Alarms...10 Overview...10 Connection...10 4-20 ma Current Loop Interface...11 OPERATION... 13 Front Panel Display and Controls...13 General Operation...13 Display Screens...14 Initial Power Up...14 Data Display Screen...14 Function Screens...15 Working with Gas Alarms...18 Overview...18 Clearing / Silencing a Gas Alarm...18 Viewing the Gas Alarm Log...18 Working with System Faults...18 Overview...18 Clearing / Silencing a Fault Alarm...18 Viewing the Fault Log...19 Fault Codes...19

Clearing the Stored PPM Log, Alarm & Fault Data...20 Working with the P-CHK Function...20 Overview...20 Keypad Functions...20 Screen Display...20 Working with the DIAGNOS Function...21 Overview...21 Keypad Functions...21 First Diagnostic Screen...21 Second Diagnostic Screen...21 Working with the Calibration Function...22 Overview...22 Calibration Procedure...22 Adjusting Calibration Factor...22 MAINTENANCE... 23 Warnings and Cautions...23 Hydrophobic Filters...23 Servicing Air Lines & Termination Filters...23 Fuses...23 Clock Battery...23 Sample Pump...23 Replacement Parts & Optional Accessories...24 Replacement Parts...24 Optional Accessories...24 Service Centers...25 Specifications...26

Introduction How to Use This Manual Thank you for investing in a BACHARACH CO2MSZ (Carbon Dioxide Gas Monitor Single Zone). This manual provides important information on how to install, operate, and service the CO2MSZ monitoring unit. To assure operator safety and the proper use of the monitor, please read, understand, and follow the contents of this manual. If you have a working knowledge of gas monitors, you will find this manual useful as a reference tool. If you are new to the use of gas monitors, you can educate yourself about the principles of infrared gas detection and the proper operation of this device by reading this manual thoroughly. Warning Statements The use of the word WARNING in this manual denotes a potential hazard associated with the use of this equipment. It calls attention to a procedure, practice, or condition, or the like, which if not correctly performed or adhered to, could result in personal injury or death. Caution Statements The use of the word CAUTION in this manual denotes a potential hazard associated with the use of this equipment. It calls attention to a procedure, practice, condition, or the like, which if not correctly performed or adhered to, could result in damage to the equipment. Hazard Symbols on Monitor This symbol indicates the need to consult this operating instruction manual when opening the enclosure. WARNING: A potential risk exists if the operating instructions are not followed. This symbol indicates the presence of electric shock hazards when the enclosure is opened. WARNING: To avoid risk of injury from electric shock, do not open the enclosure without first disconnecting AC power. Instruction 3015-4603 1

Safety Precautions AC Power Supply The CO2MSZ uses a universal power supply that accepts AC inputs of between 100 and 240 Vac, 50/60 Hz, and has a power consumption of 15 Watts. It is highly suggested that the monitor be connected directly to the AC power source, preferably on its own circuit (with UPS or surge protection). A switch or circuit breaker rated 1.0 A, 250 Vac, with a minimum terminal spacing of 3.0 mm must be attached to the monitor s AC power leads. This switch must also be located in close proximity to the monitor, and be in easy reach of the operator. This switch should also be clearly marked as the monitor s main AC disconnect device. Protective Grounding Under no circumstances should the CO2MSZ be operated without connection to a protective ground. Doing so poses a potential shock hazard and is also a violation of electrical safety standards applicable to this type of equipment. Explosive Atmosphere Do not operate this equipment in the presence of flammable liquids, vapors or aerosols. Operation of any electrical equipment in such an environment constitutes a safety hazard. Proper Exhaust Venting It is imperative that the monitor s exhaust port be vented as described in this manual. Failure to do so may constitute a safety hazard. Working Inside the Monitor Extreme care should be exercised when accessing the interior of the monitor. Only qualified electrical maintenance personnel should perform connections and adjustments. Always remove AC power before working inside the monitor. Misuse and Modifications to Monitor The protection provided by the monitor may be impaired if the monitor is used in a manner not specified by Bacharach, Inc. Changes or modifications to this monitor, not expressly approved, will void the warranty. In Case of Malfunction Do not continue to use this equipment if there are any symptoms of malfunction or failure. In the case of such occurrence, de-energize the power supply and contact a qualified repair technician or the nearest Bacharach Service Center. Use ONLY the provided knockouts for electrical and communication wiring. Drilling into the box will void the warranty. Fusing F1, F2: 1.0 A, 250 V, Type F Installation Category Installation Category II, Pollution Degree II, as defined by UL. Altitude Limit 6,562 ft (2,000 m) Cleaning Clean the outside of the monitor s case using a dry cloth DO NOT use soap and water. 2 Instruction 3015-4603

Functional Overview General Description Carbon dioxide (CO2) monitors are specified to support compliance to federal, state and local safety codes governing gas emissions. Avoiding significant CO2 gas loss reduces equipment replacement costs, maintains equipment efficiency, promotes safety, and protects the environment. The Bacharach CO2MSZ (Carbon Dioxide Gas Monitor Single Zone) is designed to continuously test for the presence of CO2 gas in an area that is located up to 500 ft (152.4 m) away from the monitor. The CO2MSZ displays that CO2 gas being monitored, along with displaying both the current gas level and the peak gas level detected in that area on its front panel LCD. The monitor retains a log of previous readings that can be easily accessed for analysis. An audible alarm and front panel indicators are provided to signal alarm and fault conditions, and relay contacts are provided that can be used to trigger external alarm devices in the event of a system fault, or if a leak (small), spill (medium), or evacuation (large) level of gas is detected. The system also includes a 4 20 ma current loop interface that can be connected to remote monitoring equipment. The CO2MSZ requires only minor periodic maintenance such as the occasional replacement of filters. The monitor incorporates active diagnostics that continuously check the system for proper operation. A front panel indicator is provided to alert an operator of system malfunctions, and fault codes are generated that enable the operator to identify the cause of the fault. Understanding Monitoring Levels Effective use of this monitor requires an understanding of what constitutes reasonable alarm set points for the type of gas being monitored. Most systems leak some gas. In a good tight installation these background levels will be acceptably low and often do not require corrective action. You can reduce nuisance alarms and needless service calls if the alarm levels are set at practical limits. The CO2MSZ is shipped with its leak, spill, and evacuate alarm levels set at 100, 300, and 500 ppm, respectively. Setting the monitor at these recommended alarm levels will satisfy the needs of most users. However, the ppm levels generated by system leaks into the environment are greatly influenced by the volume of air in the sampling area, air circulation, size of the leak, distance to the monitoring point, and a host of other variables. In some cases the alarm set points may need to be adjusted either up or down to achieve effective monitoring. Instruction 3015-4603 3

Suggested Location of Sampling Point At the point of a CO2 gas leak the gas is nearly pure. As CO2 gas is dispersed into the air, the gas molecules diffuse causing a dilution of the original concentration. The CO2MSZ measures the gas concentration at the point the sample is collected. Therefore, if the termination of the monitor s gassample line is not at the exact point of the gas leak, then the monitor will read a diluted mixture of CO2 gas and air. It should also be noted that CO2 gas is heavier than air and tends to collect below the point of a leak. Therefore a sample taken near the floor will have a greater concentration of gas than that collected above the source of a leak. Consequently, the sampling point should ideally be located as close as possible to the source of a potential leak. If this is impractical, then the alarm set points should be adjusted to compensate for the dilution of the gas. The CO2MSZ should be mounted outside of the mechanical room or at least just inside of a door to the room. This is the split architecture design for safety of the operator. The monitor should be readily accessible for easy visual monitoring and servicing. The total length of the sample line + exhaust line can be up to 500 ft (152.4 m). If the area around the monitor is not well ventilated, then an optional exhaust line and purge line can be run to an outside location. The total length of the exhaust line + purge line can not exceed 200 ft (61.0 m). It may be necessary to perform a smoke test of the mechanical room to determine the best monitoring point. The smoke test would provide the pattern of air currents present in the room. CO2MSZ Gas Leak Monitor Mechanical Room Placement 4 Instruction 3015-4603

Installation Installation Considerations Warnings and Cautions WARNING: Explosion hazard! Do not mount the CO2MSZ in an area that may contain flammable liquids, vapors or aerosols. Operation of any electrical equipment in such an environment constitutes a safety hazard. WARNING: Shock hazard! Always disconnect AC power before working inside the monitor. CAUTION: Drilling holes in the CO2MSZ enclosure may damage the unit and will void the warranty. Please use knockouts provided for electrical connections. CAUTION: The CO2MSZ contains sensitive electronic components that can be easily damaged. Be careful not to touch or disturb any of these components. Inspection The CO2MSZ has been thoroughly inspected and tested prior to shipment from the factory. Nevertheless, it is recommended that the monitor be re-checked prior to installation. Inspect the outside of the enclosure to make sure there are no obvious signs of shipping damage. Open the enclosure and inspect the interior of the monitor for loose components that may have become dislodged during shipment. If damage is discovered, please contact the nearest Bacharach Service Center for assistance. Locating the Monitor Place the monitor in a location that will require no more than 500 ft (152.4 m) of tubing (total of sample line + exhaust line) to reach the sampling area. Since the monitor uses ambient air to zero its gas sensor, the monitor should be located in an area that normally does not contain refrigerant gas. If an exhaust line is not used, then locate the monitor in a well ventilated area so that the exhaust gas does not accumulate around the monitor s ventilation holes. The CO2MSZ should be operated in an environment that is between 32 and 122 F (0 and 50 C); has a relative humidity of between 5 and 90% non-condensing; and is at an altitude of no more than 6,562 ft (2,000 m). The area should also be relatively free of dirt, grease, and oils that could adversely affect the operation of the monitor. The location should allow the monitor to be easily accessible for visual monitoring and servicing. Instruction 3015-4603 5 Mounting Instructions

The CO2MSZ should be installed plumb and level, and securely fastened to a rigid vertical mounting surface. The enclosure utilizes keyhole mounting brackets designed for ¼ inch fasteners. Install the four screws as shown in the diagram below or by using the provided mounting template. Allow the screw heads to protrude approximately 1/4". Enclosure Mounting Specs Hold the monitor flat against the mounting surface and allow it to slide down engaging the screw heads in the keyhole slots of the mounting brackets. Adjust the screws as necessary to hold the monitor securely against the mounting surface. Connecting Gas Sample, Purge, and Exhaust Lines Overview A single gas-sample line needs to be run from the CO2MSZ to the area of the facility to be monitored. An optional purge line can be run to bring fresh air into the monitor for detector zeroing purposes. And an optional exhaust line can be installed to vent the sample gas away from the monitor. All tubing connections are made on the bottom of the enclosure as shown in the illustration below. Purge Air Inlet Port CO2MSZ Bottom View Gas Sample Inlet Port ½" / ¾" Service Knockout* ½" / ¾" Service Knockout* Gas Sample Exhaust Port * There is an additional Service Knockout on top of the case 6 Instruction 3015-4603

Tubing Considerations Use ¼" outside diameter (0.040" wall) flex tubing for all air lines (P/N 304-2742 or equivalent). The tubing should be clean and free of moisture or other contaminants. The tubing should be cut cleanly with a sharp knife and care should be taken not to distort the tubing end. All tubing bends should have a radius of no less than 5" to ensure proper airflow. If kinks or obstructions occur in the line the monitor may not function properly. Connecting the Gas-Sample Line Please refer to Section Suggested Location of Sampling Point (Page 4) to learn more about where to take a gas sample. The gas-sample line can be up to 500 ft (152.4 m) in length. The combined length of the sample line and exhaust line (if one is used) should not exceed 500 ft. The end of this line should be placed near the potential leak source and positioned to reduce the possibility of mists, aerosols, oil, water, dust, or other contaminates from being drawn into the monitor. For added protection, a termination filter (P/N 3015-3420) supplied with the monitor must be attached to the end of this line. CAUTION: The introduction of contaminants through the gas-sample line can result in serious and permanent damage to the monitor. Connecting the Purge Line The purge line functions to bring fresh air into the monitor for the purpose of purging the detector and setting its baseline reading. This purge line is required if the monitor is located in an area that does not contain fresh air. The purge line can be up to 100 ft (30.5 m) in length. Ideally, this line should terminate in an area known to contain fresh air. To connect the purge line to the monitor, simply push the tubing into the Purge Air Inlet Port. If the purge line terminates outside the building, position the tubing so that no water or moisture can enter the line. For added protection from contaminates entering the monitor, a termination filter (P/N 3015-3420) must be attached to the end of this line. Connecting the Exhaust Line The exhaust line functions to carry the exhausted gas sample away from the monitor, and is required if the monitor is located in a confined, poorly ventilated area. If no purge line is used, it is a good idea to vent the exhausted gas sample away from the monitor to prevent erroneous readings due to improper zeroing of the detector. The exhaust line can be up to 100 ft (30.5 m) in length. Ideally this line should terminate outdoors in a location that is not exposed to the elements. Connect the exhaust line to the monitor by firmly pushing the tubing onto the Gas Sample Exhaust Port s barbed fitting. Ensure that no loops or dips are present that could trap condensate. This is likely as outside air can be cooler than instrument. Note that the exhaust line does not require a termination filter. Termination Filter (P/N 3015-3420) Instruction 3015-4603 7

Interior Schematic Interior Schematic LINE FUSES 1.0A, 250V, F AC INPUT GROUND STUD AC INPUT TERMINALS FACTORY DEFAULT SWITCH 4 20 ma (Output only - DO NOT apply power!) HYDROPHOBIC FILTER *AIR SAMPLE PUMP PURGE AIR IN HYDROPHOBIC FILTER EXTERNAL ALARM RELAY CONNECTOR IR BENCH GAS IN IR BENCH GAS OUT *NOTE: The plastic cable tie surrounding the air pump is to ensure safe handling during shipping. Please remove before operating. 8 Instruction 3015-4603

Electrical Wiring The CO2MSZ uses a universal power supply that accepts AC inputs of between 100 and 240 Vac, 50/60 Hz, and has a power consumption of 15 Watts. It is highly recommended that the monitor be connected directly to the AC power source, preferably on its own circuit. The connection should be completed with UL approved multi-conductor wire (14 18 AWG), rated 300 Vac at 105 C. Locate a convenient service knockout and install electrical conduit in the typical manner. Locate the AC Input Terminals and Ground Stud on the inside of the monitor (Page 8). Secure the incoming AC power neutral (white) and live (black) wires to the LINE 1 and LINE 2 terminals. Using the supplied crimp-on ring terminals, washers, and nuts, connect the incoming AC power ground wire (green) to the monitor s AC Input Ground Stud, and then install a separate wire between the ground stud and the GND terminal. A switch or circuit breaker rated 1.0 A, 250 Vac, with a minimum terminal spacing of 3.0 mm must be attached to the monitor s AC power leads. This switch must also be located in close proximity to the monitor, and be in easy reach of the operator. This switch should also be clearly marked as the monitor s main AC disconnect device. AC Power Connections WARNING: Electrical installation should be performed by a certified electrician, and should comply with all applicable NEC/CEC and local electrical safety codes. WARNING: The AC power ground wire must first be connected to the monitor s ground stud. Under no circumstances should this monitor be operated without a protective ground. Doing so poses a potential shock hazard, and is also a violation of electrical safety standards applicable to this type of equipment. CAUTION: Drilling holes in the CO2MSZ enclosure may damage the unit and will void the warranty. Please use knockouts provided for electrical connections. Instruction 3015-4603 9

Connecting External Alarms Overview The CO2MSZ includes four SPDT relays whose contacts are rated 2 A at 250 VAC (inductive) 5 A at 250 VAC (resistive). These relays are used for the connection of external alarm devices that are activated when the relay is energized. The relays are factory assigned to energize under the following conditions: Relay #1 Leak Alarm Point 500 ppm Relay #2 Spill Alarm Point 700 ppm Relay #3 Evacuate Alarm Point 1000 ppm Relay #4 Fault System Fault Event The alarm points of relays #1, #2, and #3 are set using the monitor s LEAKLVL, SPILLLVL, and EVACLVL function screens (Page 16). Connection Use any of the service knockouts to gain cable access to the interior of the monitor. Locate the External Alarm Relay Connector (Page 8). Secure the leads from the external alarm device and its power source to the connector as shown in the diagram below. The diagram on Page 11 shows a typical alarm device being connected to Relay 1. Note how power to this device is being tapped off the monitor s AC input. External Alarm Relay Connector Each relay may be connected as normally open (NO), or normally closed (NC). The relay contacts are rated 2 A at 250 VAC (inductive) 5 A at 250 VAC (resistive). Power for the external alarm devices may be supplied from an external power source, or from the monitor s AC input terminals. 10 Instruction 3015-4603

Typical External Alarm Relay 1 Wiring Jumper the Neutral line of an external power source or the monitor s AC input to the Common terminals on the relay connector. Connect one end of the strobe or horn to the NO terminal of whichever level of alarm is appropriate for the application. The other end of the strobe or horn is connected to the other leg of the external power source. For protection, install an in-line fuse of the appropriate size and design for the external alarm device being used. 4 20 ma Current Loop Interface An external 4 20 ma monitoring device (e.g., chart recorder) can be connected to the CO2MSZ using a shielded-twisted-pair cable. Use any of the service knockouts to gain access to the interior of the monitor. Locate the 4 20 ma Connector (Page 8), remove it from the circuit board, and then remove the resistor or shorting wire from its terminals. IMPORTANT! The 4-20mA output is a "floating" ground type and must be used with a loop-powered isolator as an accessory such as a Dataforth part number DSCL21-01. NOTE: A 100 ohm, ¼ W resistor must be inserted into the 4 20 ma connector if no external monitoring device is used. Failure to insert this resistor may cause a loop fault code <0010> to occur (Page 19). Secure the wire leads from the external monitoring device to the 4 20 ma connector as shown in the diagram below, making sure that the polarity at this connector matches the wiring at the monitoring device. The default current-to-ppm factor is set to 0.016 ma = 1 ppm, providing a measurement range 0 ppm (4 ma) to 1,000 ppm (20 ma). The current-to-ppm factor can be changed using the monitor s LOOP function (Page 16). To facilitate loop zero and span checking, note that when the LOOP function is selected the loop output is set to 20 ma, and upon exiting this function the loop output is set to 4 ma. 4 20 ma Current Loop Connector CAUTION: Never apply power to the 4 20 ma Current Loop Connector from an external power supply. Connect only a load resistor and/or a floating measurement device. Instruction 3015-4603 11

Notes: 12 Instruction 3015-4603

Operation Front Panel Display and Control Display Screen ENTER Press this button to: 1) Clear peak reading 2) Save a function screen s displayed value SILENCE / QUIT Press this button to: Keypad Use these buttons to: 1) Enter function mode and then move arrow (>) on screen to the desired function 2) Scroll through data 3) Change a function s value MONITOR ON Light (Green) 1) Flashes during warm-up 2) Lights steady during normal operation SYSTEM FAULT Light (Yellow) Flashes when any one or more of the faults listed on Page 19 occur ALARM Light (Red) Flashes when the detected gas level exceeds any of three preset alarm points 1) Acknowledge a system fault or gas alarm by turning OFF the internal audible alarm and de-energizing the corresponding fault/alarm relay 2) Return to the previous screen without saving data when in the function mode General Operation Once the CO2MSZ has been installed, set up, and powered ON, the monitor will make measurements in the area being sampled for CO2 gas without further operator intervention. The results of those measurements are shown on the front panel display. MEASURE 00955pk 340ppm CO2 In the example shown above, MEASURE indicates that the CO2MSZ is actively monitoring for CO2 gas, and that currently a concentration of 340 ppm is being detected. This display also indicates that a peak measurement of 955 ppm has been made. An operator can reset the peak value to zero by pressing the ENTER button. A log of up to 200 previous measurements can be viewed using the PPM LOG function (Page 15). If the detected gas level exceeds the preset Leak, Spill, or Evacuate alarm point, then the monitor responds by turning ON the front panel ALARM (red) light and energizing the corresponding alarm relay. If the internal audible alarm is turned ON, it too will activate (AUDALRM Page 16). Optional external alarm devices can be connected to the alarm relays to alert personnel that a Leak, Spill, or Evacuate alarm condition has occurred (Page 10). Pressing the front panel SILENCE button will acknowledge an alarm and turn OFF all alarm indicators with the exception of the front panel ALARM light. The alarm circuit will reactivate, however, if the alarm condition is not cleared within the time period set by the SILENCE function (Page 17). The ALARM light will turn OFF after the detected gas level goes below the lowest alarm point and after the SILENCE button is pressed. Instruction 3015-4603 13

If a system fault occurs (see Fault Code list on Page 19), the monitor responds by turning ON the front panel SYSTEM FAULT (yellow) light and energizing the fault relay. If the internal audible alarm is turned ON, it too will activate (AUDALRM Page 16). An optional external alarm device can be connected to the fault relay to alert personnel that a system fault has occurred (Page 10). Pressing the front panel SILENCE button will acknowledge the fault and turn OFF all alarm indicators with the exception of the front panel SYSTEM FAULT light. The alarm circuit will reactivate, however, if the fault condition is not cleared within the time period set by the SILENCE function (Page 17). The SYSTEM FAULT light will turn OFF only after the cause of the fault has been eliminated. A log of the alarm and fault events can be viewed using the monitor s ALARMS and FAULTS function (Page 15). Display Screens Initial Power Up When the CO2MSZ is first powered up all front panel lights are turned ON, and a splash screen appears showing the monitor s firmware revision level. After a brief moment the Warm Up screen is display along with the front panel MONITOR ON light (green) blinking. BACHARACH VERSION x.xx WARM UP The monitor takes 15 minutes to warm up; after which, the MONITOR ON light glows steady and the Data Display screen is displayed. Data Display Screen MEASURE 00955pk PURGE 00955pk PRES CHK 00955pk 340ppm CO2 340ppm CO2 340ppm CO2 During normal operation, the Data Display screen shows when the monitor is performing the following three functions: MEASURE indicates that the monitor is actively measuring the CO2 gas level at the sample point. In the example screens shown above, the monitor is currently detecting 340 ppm of CO2 gas, and that a peak measurement of 955 ppm has occurred. To reset the peak value to zero, press the ENTER button. PURGE is displayed when the monitor is resetting its infrared detector to a baseline ppm value using fresh air that is being drawn in through the Purge Air Inlet Port. This purging process is performed on an as needed basis, which is normally once every 6 to 8 minutes. PRES CHK is displayed when the monitor is performing an atmospheric pressure check, which is done to ensure the accuracy of the gas measurement under varying atmospheric conditions. This pressure check is performed every 30 minutes. 14 Instruction 3015-4603

Function Screens The Function screens are used to display stored data and to set up the monitor. From the Data Display screen, press any Keypad button to display the first Function Menu screen. Next, use the Keypad buttons to move the arrow (>) on the display next to the desired function, and then press the ENTER button to select that function. >PPM LOG FAULTS ALARMS DIAGNOS >GASTYPE SPILLVL LEAKLVL EVACLVL >LOG INT AUDALRM LOOP CLOCK >SILENCE ZONETMP SQUELCH CAL >P-CHK Once a function has been selected, use the Keypad to scroll through the displayed data or to change a parameter associated with that function. Press ENTER to save newly entered parameters. Press the QUIT button to return to the previous screen without saving. If no buttons are pressed within 90 seconds after selecting a function, the monitor will return to the Data Display screen. PPM LOG Contains records of the last 200 measurements. Each record shows the measurement s date, time, and ppm level. The interval at which the measurements are logged is determined by the LOG INT function. #025 995PPM @ 07/05/07 15:35 Use the Keypad Up and Down buttons to change the record number by a factor of 1. Use the Right and Left buttons to change the record number by a factor of 10. Press QUIT to return to the previous screen. In the example on the right, record #025 shows that a level of 995 ppm was measured on 07/05/07 at 15:35. The PPM Log can be cleared as described in Section Clearing the Stored PPM Log, Alarm & Fault Data (Page 20). ALARMS Contains records of the last 30 alarm events, with the monitor s most recent alarm being shown when the Alarm screen is first displayed. After 30 events have been recorded, the newest record overwrites the oldest. Each record displays either LEAK, SPILL, or EVAC including the date and time the alarm occurred. Use any of the Keypad buttons to scroll through the other alarm records. Press QUIT to return to the previous screen. Refer to Working with Gas Alarms (Page 18). The ppm levels at which alarms occur are set using the LEAKLVL, SPILLLVL, and EVACLVL functions. In the example on the right, record #03 shows that a spill event occurred on 07/10/07 at 15:06. #03 SPILL @ 07/10/07 15:06 FAULTS Contains records of the last 30 fault events, with the monitor s current fault status being shown when the Fault screen is first displayed. After 30 events have been recorded, the newest record overwrites the oldest. Each record lists an event s numeric fault code plus the date and time the fault occurred. Use any of the Keypad buttons to scroll through the other fault records. Press QUIT to return to the previous screen. Refer to Working with System Faults (Page 18). #15 <1000> @ 07/10/07 12:37 In the example on the right, record #15 shows that a Purge Flow Fault <1000> occurred on 07/10/07 at 12:37. Instruction 3015-4603 15

DIAGNOS Enters the diagnostic function. Press the Up Arrow Keypad button to toggle between the monitor s two diagnostic screens. Refer to Working with the DIAGNOS Function (Page 21). 4.26500v <0000> 24.5cD 14.00psi 0.4ppm 0.00 0.00002au 4.260v GASTYPE CO2 gas monitors do not have a library of other gases to choose from, therefore CO2 is the only gas type listed. Press QUIT to return to the previous screen. LEAKLVL Sets the Leak Alarm level, adjustable from 1 to 1999 ppm. Factory default is 500 ppm. The Leak Alarm level cannot be set higher than either the Spill or Evacuate Alarm levels. Use the Keypad to set the desired Leak Alarm level, and then press ENTER to save that level and return to the previous screen. SPILLLVL Sets the Spill Alarm level, adjustable from no lower than the Leak Alarm level to a maximum value of 1999 ppm, but not higher than the Evacuate Alarm level. Factory default is 700 ppm. Use the Keypad to set the desired Spill Alarm level, and then press ENTER to save that level and return to the previous screen. EVACLVL Sets the Evacuate Alarm level, adjustable from no lower than the Spill Alarm level to 1999 ppm. Factory default is 1000 ppm. Use the Keypad to set the desired spill level alarm level, and then press ENTER to save that level and return to the previous screen. LOG INT Sets the interval at which measurements are logged to memory from 1 to 9999 minutes. Factory default is 10 minutes. The logged measurements can be viewed using the PPM LOG function. Use the Keypad to enter the desired value, and then press ENTER to save that value and return to the previous screen. LOOP Adjusts the loop factor of the 4 20 ma current loop. Factory default is 0.016 ma per ppm, which provides an output range of 0 ppm (4 ma) to 1,000 ppm (20 ma). Use the Keypad to set the desired loop factor, and then press ENTER to save that value and return to the previous screen. SELECT GAS TYPE CO2 EDIT LEAK LEVEL 500 PPM EDIT SPILL LEVEL 700 PPM EDIT EVAC LEVEL 1000 PPM LOG INTERVAL IS 0010 min EDIT LOOP FACTOR 0.016 ma/ppm To facilitate loop zero and span checking, note that when the LOOP function is selected the loop output is set to 20 ma, and upon exiting this function the loop output is set to 4 ma. AUDALRM Allows the monitor s internal audible alarm to be associated with any function of the monitoring system. Factory default is OFF. Use the Keypad to select the desired audible alarm function, and then press ENTER to save that value and return to the previous screen. Audible Alarm Settings: OFF, ANY ALARM, SYSTEM FAULT, LEAK ALARM, SPILL ALARM, EVAC ALARM, MONITOR STOPPED NOTE: MONITOR STOPPED indicates there is a critical system fault, and the monitor is no longer functioning correctly. AUDIBLE ALARM IS OFF 16 Instruction 3015-4603

CLOCK Sets the monitor s date and time. Use the Keypad to enter the correct date and time, and then press ENTER to save those values and return to the previous screen. Time is displayed in a 24 hour format, while the date is displayed as mm/dd/yy. SILENCE Used to enter a length of time for which the internal audible alarm and the external alarm are turned OFF when the front panel SILENCE button is pressed. The factory default is 300 seconds (5 minutes). If the cause of the alarm/fault has not been cleared at the end of this time period, the internal audible alarm and the external alarm device are reactivated. Use the Keypad to enter the desired time period, and then press ENTER to save that value and return to the previous screen. SQUELCH Sets a value of between 0.0 and 100 ppm that prevents the display of measurements below that value. Factory default is 0 ppm. For example, if the squelch setting is set to 5 ppm, then the monitor will not display measurements that are below that value. Use the Keypad to enter the desired value, and then press ENTER to save that value and return to the previous screen. ZONETEMP Used to enter the temperature of the area being monitored in C, thus giving a more accurate ppm reading. The factory default is 25 C. Use the Keypad to enter the desired temperature, and then press ENTER to save that value and return to the previous screen. CAL Used to change the monitor s calibration factor. This function is to be used ONLY with instructions from a Bacharach Service Center. Factory default is 1.000. P-CHK This Pressure Check function displays the current manifold pressure and the stored ambient pressure in psia, along with the difference between these two pressures and the current fault code. Refer to Working with the P-CHK Function (Page 20). SET DATE & TIME 07/10/07 15:30 SILENCE TIMEOUT 0300 sec SQUELCH BELOW 5 ppm TEMP AT ZONE = 25 degc R717 CALFACTOR 1.000 14.72 * AMB14.81 0.09dif <0000> Instruction 3015-4603 17

Working with Gas Alarms Overview If the CO2 ppm level in the area being monitored exceeds its preset Leak, Spill, or Evacuate Alarm level (Page 16), the CO2MSZ will detect this alarm condition and turn ON the front panel ALARM light (red). Additionally, an external alarm device may activate and the monitor s internal audible alarm may sound if those features have been enabled (Pages 10 & 16). Clearing / Silencing a Gas Alarm Once the gas-alarm circuit has been triggered all alarm indicators remain turned ON, even after the detected gas level returns to normal. Press the SILENCE button to clear all gas-alarm indicators after the cause of the alarm has been cleared and the detected gas level has dropped below all alarm levels. Pressing the SILENCE button while a gas-alarm condition still exists causes the internal audible alarm and all external alarm devices that are connected to the alarm relays to turn OFF for a period of time as set by the SILENCE function (Page 17). The front panel ALARM light remains ON, however, as an indication that an alarm condition still exists, but will automatically turn OFF once the gas level returns to normal. The alarm circuit will reactivate at the end of the silence period if the detected gas level is still above an alarm level. Viewing the Gas Alarm Log From the Data Display screen, use the Keypad buttons to place the arrow (>) on the display next to the ALARMS function. Then press ENTER to display the alarm log. The alarm log shows the type of alarm (LEAK, SPILL, or EVAC), plus the date and time it occurred. If CLEAR is displayed, this indicates that an alarm was acknowledged at the date and time shown. Immediately after selecting the ALARM function, the most recent alarm event is displayed. In the example on the right, record #03 shows that a #03 SPILL @ Spill Alarm occurred on 07/10/07 at 15:06. If more than 30 alarm events 07/10/07 15:06 have occurred, then the newest event overwrites the oldest. The Alarm Log can be cleared as described in Section Clearing the Stored PPM Log, Alarm & Fault Data (Page 20). Working with System Faults Overview If a system malfunction occurs, the CO2MSZ will detect the problem and turn ON the front panel SYSTEM FAULT (yellow) light. Additionally, an external alarm device may activate and the monitor s internal audible alarm may sound if those features have been enabled (Pages 10 & 16). Clearing / Silencing a Fault Alarm The SYSTEM FAULT light and all other fault indicators will automatically turn OFF after the cause of the fault has been eliminated. Pressing the SILENCE button while a fault condition still exists causes the internal audible alarm and the external alarm device that is connected to the fault relay to turn OFF for a period of time as set by the SILENCE function (Page 17). The front panel SYSTEM FAULT light remains ON, however, as a reminder that a fault condition still exists. The alarm circuit will reactivate at the end of the silence period if the cause of the fault has not been corrected. The SYSTEM FAULT light will automatically turn OFF once the fault has been cleared. 18 Instruction 3015-4603

Viewing the Fault Log From the Data Display screen, use the Keypad buttons to place the arrow (>) on the display next to the FAULTS function. Then press ENTER to display the fault log. The fault log shows the monitor s current fault status. If the fault is still present when the FAULTS function is selected, then the current cause of the #03 <0800> @ fault is displayed along with the date and time it occurred. If the cause of the 07/12/07 08:17 fault has been cleared, then the fault log will show <0000> along with the date and time the fault was cleared. Use the keypad buttons to scroll #04 <0000> @ through the fault log. In the examples shown on the right, record #03 shows 07/12/07 08:30 that a Zone Flow Fault (fault code <0800>) occurred on 07/12/07 at 08:17, while record #04 shows that the fault was cleared on 07/12/07 at 8:30. The cause of the fault is identified by a numeric fault code. To convert the fault code into a text description of the fault, first press the ENTER button and then use the Keypad buttons to scroll through the display until the text description of the fault appears. If the fault code is a combination of two or more faults, then continue to use the Keypad buttons until all fault text descriptions have been displayed. For example, the fault code <1800> represents the combination of both a Zone Flow <0800> and a Purge Flow <1000> fault as shown on the right. The Fault Log can be cleared as described in Section Clearing the Stored PPM Log, Alarm & Fault Data (Page 20). FAULT CODE<1800> 12 ZONE FLOW FAULT CODE<1800> 13 PURGE FLOW Fault Codes FAULT CODES ARE ADDITIVE. For example: A fault code of <1800> indicates that both a Purge Flow Fault <1000> and a Zone Flow Fault <0800> have occurred. <0001> Box Temperature Fault: Enclosure temperature is outside normal range (or IR detector has failed). Check that the monitor is not being subjected to extreme temperatures. Verify that the ventilation holes are not obstructed. Use the DIAGNOS function (Page 21) to check the Box Temperature. <0200> Gain Set Fault: The digipot autotune sequence has failed. This fault will only occur on first boot up or after a firmware upgrade. Call the factory for further instructions. <0400> A/D Fault: A fault has occurred in the analog-to-digital circuitry. Contact the factory with this information for further instructions. <0800> Zone Flow Fault: Check for: A kink in the gas-sample line or exhaust line; a blocked external termination filter; a blocked internal hydrophobic filter (Page 8); a failed pump. <0002> Bench Temperature Fault: Optical bench is outside normal operating range (or IR detector has failed). Check that the monitor is not being subjected to extreme temperatures. <0004> - Manifold Pressure Fault: The manifold pressure is outside normal operating range (or IR detector has failed). Enter the DIAGNOS function(page 21) and record ALL data. Call the with this information for further instructions. <0010> Loop Fault: The 4 20 ma current loop is open, or there is a high resistance in the circuit. Check the wiring to the load/monitoring circuit. If this feature is not being used, a 100 ohm resistor must be connected to the 4 20 ma connector (Page 11). <0100> Zero Filter Fault: There is CO2 gas present in the purge air. Locate the monitor in an area containing fresh air, or install a purge air line. Refer to Locating the Monitor (Page 5). <1000> Purge Flow Fault: Check for: A kink in the purge line; a blocked external termination filter; a blocked internal hydrophobic filter (Page 8); a failed pump. Once the blockage has been cleared, the monitor will return to normal operation after the monitor completes a purge cycle. <4000> Zero Fault: The IR detector s output voltage is out of tolerance. Enter the DIAGNOS function (Page 21) and record ALL data. Call the factory with this information for further instructions. <8000> Clipping Fault: The detector voltage may be out of tolerance. Use the DIAGNOS function (Page 21) to check the IR detector voltage. Call the factory with this information for further instructions. Instruction 3015-4603 19

Clearing the Stored PPM Log, Alarm & Fault Data Up to 200 gas measurements, and 30 alarm and fault events are stored by the monitor. To clear stored data, first display the data to be cleared by using the PPM LOG, ALARMS or FAULTS function (Page 15). Next, press the Right Arrow Keypad and ENTER buttons at the same time. A single, long tone should be heard when the data has been successfully cleared. Working with the P-CHK Function Overview The P-CHK function (Pressure Check Function) (Page 17) is useful to a service technician for troubleshooting a flow fault problem. The monitor will trigger a flow fault if the pressure drop from ambient is less than 0.2 psi during a purge cycle, and 0.5 psi during a measurement cycle. Keypad Functions From the Data Display screen, use the Keypad buttons to place the arrow (>) on the display next to the P-CHK function. Then press ENTER to display the Pressure screen. The Left Arrow Keypad button toggles the purge valve open and closed. An asterisk () appears when the purge valve is open (purging). The Down Arrow Keypad button toggles the pump ON and OFF. Pressing the ENTER button stores the current manifold pressure shown on the left to the ambient pressure shown on the right (must be done with the pump OFF). Screen Display 14.72 * AMB14.81 0.09dif <0000> Manifold Pressure * Stored Ambient Pressure Pressure Difference Fault Code Manifold Pressure Current manifold pressure in psia. Stored Ambient Pressure Stored ambient pressure in psia. Pressure Difference The difference between the current manifold pressure and the stored ambient pressure. Fault Code Current fault code (Page 19). Purge Valve Asterisk (*) When viewing the Pressure screen, the purge valve can be opened and closed by pressing the Left Arrow Keypad button. An asterisk appears on the display when the purge valve is open. 20 Instruction 3015-4603

Working with the DIAGNOS Function Overview The DIAGNOS function displays sensor data and status information useful to a service technician for troubleshooting various fault conditions. Explanations of the data shown in these screens are given below. Keypad Functions From the Data Display screen, use the Keypad buttons to place the arrow (>) on the display next to the DIAGNOS function. Then press ENTER to display the first of two Diagnostic screens. Press the Up Arrow Keypad button to toggle between the First and Second Diagnostic screen. First Diagnostic Screen 4.26500v <0000> 24.5cD* 14.72psi Bench Voltage Fault Code Detector Temperature C * Manifold Pressure 0.00250n <0000> 29.5cB* 14.72psi Noise Box Temperature C Fault Code * Manifold Pressure In the first diagnostic screen, the user can toggle between displaying the Bench Voltage / Noise and Detector Temperature / Box Temperature by pressing the Right Arrow Keypad button. Bench Voltage This is the current peak-to-peak output of the IR detector. In the absence of CO2 gas this value can range from 3.90000V to 4.50000V. Noise The Noise value is a 16 point running average of the noise portion of the IR detector s output. This reading is valuable mainly when CO2 gas is NOT present. Detector Temperature This is the current detector temperature in C. Box Temperature This is the current internal enclosure temperature in C. Fault Code Current fault code. A value of <0000> indicates that no faults are being detected. Manifold Pressure Current manifold pressure in psia. Purge Valve Asterisk (*) The purge valve can be opened and closed by pressing the Left Arrow Keypad button. An asterisk appears on the display when the purge valve is open. Second Diagnostic Screen 0.4ppm 0.00 0.00002au*4.260v PPM Level µmole/liter Avg. Absorption Unit * Detector Voltage PPM Level Parts Per Million Level is the current detected gas level, and is the volume concentration referenced to standard temperature and pressure. Average Absorption Unit This is the optical absorbency. In the absence of CO2 gas the absorbency is 0.00000 au. When sampling CO2 gas, its value varies proportionally with the gas concentration. µmoles/liter This is the absolute concentration in micro-moles per liter of CO2 gas. Detector Voltage This is a running average of the IR detector s bench voltage as displayed in the First Diagnostic screen. Purge Valve Asterisk (*) When viewing the diagnostic screen, the purge valve can be opened and closed by pressing the Left Arrow Keypad button. An asterisk appears on the display when the purge valve is open. Instruction 3015-4603 21