Space Saver. New easy guide. Connecting your Space Saver to a central heating system. Issue 001 February 2018 ENGLISH UK IRL SmithsEP.co.

Similar documents
Space Saver. New Easy Guide. Connecting your Space Saver to a central heating system BEFORE AFTER

Sargasso Range. Installation manual. Sargasso S. Issue 001 January 2018 ENGLISH UK IRL SmithsEP.co.uk

Pedestal Range. Installation and user manual. Kiosk. Trafalgar. Tube. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk

Space Saver. Installation and user manual SS3 SS5 SS7 SS9. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk

Sargasso Range. Installation manual. Sargasso A. Issue 001 January 2018 ENGLISH UK IRL SmithsEP.co.uk

Space Saver. Installation and user manual. Issue 001 March 2018 ENGLISH UK IRL SmithsEP.co.uk. Issue March 2018 smithsep.co.

Sargasso Range. A new range of radiant panels for heating commercial applications

Hydroflame. Flame-effect fan convectors Installation and User Guide Elite and Classic Models. Contents

Aegean Range. A new range of fan coils for heating and cooling commercial applications

Signature, Sovereign, Sentry, Sentinel, Staccato Fan-Assisted Radiator. Installation & User Guide

Bar valve with fixed and adjustable shower heads. Installation guide. Midas Plus installation instructions Page 1

AQ150:Midas 10/9/15 14:50 Page 1 AQ150. Thermostatic bar mixer valve with adjustable head. Installation guide

INSTALLATION & TECHNICAL MANUAL

Aquamixa. Thermo. Thermostatic shower valve with manual bath fill

INSTALLATION & TECHNICAL MANUAL

Thermostatic bar mixer valve with adjustable head Installation guide

Please tape down. NewTeam Ltd. Customer Service Dept. Brunel Road Earlstrees Industrial Estate Corby Northants NN17 4JW

SEALED THERMAL STORE

ENERSTORE. Vented Hot Water Storage System INSTRUCTIONS PLEASE LEAVE WITH HOUSEHOLDER

VD 3401 Chauffage central Installation, Operating, Maintenance and After Sales Manual

ADVANCE ECB ELECTRIC COMBINATION BOILER

Turboboost SHOWER PUMPS. Installation Manual. 1.5 bar and 2.0 bar

Please tape down. NewTeam Ltd. Customer Service Dept. Brunel Road Earlstrees Industrial Estate Corby Northants NN17 4JW

SHOWER PUMPS. Installation Manual. 1.5 bar and 2.0 bar

Assessment Schedule - TS.6

CPC-180-ABNAB. 180 litres, 535mm x 1550mm high

Panel Radiators. Installation and operating instructions. ThermaRad Classic.

Installation Instructions and User Guide. Thermostatic Recessed Dual Control Shower Valve. Models covered: CAS SHCVO C, COB SHCVO C, ORB SHCVO C,

ferroli Boiler Replacement Maxima 35C- Modena HE

SINGLE LEVER CERAMIC DISC MANUAL SHOWER VALVE

How to keep your home safe and dry. Start here

HW3 Handwash Installation and Operating Instructions

Surface Temperature Tests on an LST Fan Convector

Installation Instructions and User Guide Thermostatic Recessed Dual Control Shower Valve

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Quartz. Thermo. Concealed shower valve with adjustable head. Quartz Thermo installation guide page 1

Your Central Heating System

Stored Water District Heating Interface Units. Heat Interface Units

INSTALLATION GUIDE AND WARRANTY INFORMATION

Installation Instructions and User Guide

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

OWNER S GUIDE SEQUENTIAL THERMOSTATIC SHOWER VALVE. 150mm Inlet Pipe Centres. Shower Control. Handles and. may differ depending.

MIDAS. Installation instructions 110/220

warm water underfloor heating installation manual v4b-aug 08 Nu-Heat design innovation expertise service

Installation Instructions and User Guide Thermostatic Recessed Dual Control Shower Valve with Integral Diverter

Understand and apply domestic central heating system installation and maintenance techniques

Aquatique. Shower heads. Fixed and adjustable height heads. Aquatique shower kits installation guide page 1

JANUS 3 CIRCULATOR WATER HEATER INSTALLATION, COMMISSIONING & SERVICING INSTRUCTIONS G.C. No

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Installation Instructions Flute Tap Range

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

Dream DCV. Thermostatic Dual control mixer valve range. Installation guide

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C, 140 AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS

IMAGINATION SOLAR LTD. Installation Guide B1. Planning the Plumbing and Wiring

Mini Tender Section 1.1 External Wall Insulation, Mechanical and Electrical Installation

Energy Efficiency Rating

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

PANDORA HEAT BANKS OXFORD BROOKES, HARCOURT HILL. Operation and Maintenance. THERMAL INTEGRATION LTD. Tel: Internet:

FRANKE MINERVA 3-IN-1 HOT WATER TAP HEATING TANK INSTALLATION GUIDE

Kiko Concealed Shower Mixing Valve KK80010CP

HHIC consumer guide to gas boiler servicing

MEGAFLO HE Iss 1

Energy Performance Certificate

Contents. Warning: Installation... 2 Warning: Operation...2 Warning: Disposal...3

Inta City Shower Mixing Valve CT20010CP

Kiko Bath Shower Mixing Valve KK90015CP

GENERAL FITTING GUIDE THERMOSTATIC BAR SHOWER MIXER with RIGID RISER KIT

Installation guide Billi B-3000 Sparkling Dual levered slimline tap option

Packaged Solutions. Basic Packages

Tristor MF. Installation Guide

Beautifully Traditional

Enzo Safe Touch Thermostatic Shower EZ10010CP & EZ10014CP

Enzo Concealed Shower Mixing Valve

Alpha CombiMax 350 and 600

THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

POWER SHOWERS Models 4500M 5002M 4500T 5002T

DOMESTIC HEATING CONTROLS ARE EASY PART 1 - THE BASICS

Electric Flow Boiler

Deluge Shower Mixing Valve 10045CP

Combined electric boiler and domestic hot water store

INTA ION MODERN BAR / BATH SHOWER MIXER CP

INSTALLATION INSTRUCTIONS OWNERS GUIDE & WARRANTY STATEMENT

Puro Mini Dual Control Shower Mixer PU90010CP

T550i power shower pump Installation and operating instructions

Baxi System 100 HE Plus. User s Operating Instructions. Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler

Installation Instructions and User Guide Thermostatic Recessed Three Control Shower Valve with Integral Twin Stopcocks

Aqua & Instantaneous Electric Shower Installation Instructions SERVICE POLICY

Installation Instructions and User Guide Thermostatic Recessed Three Control Shower Valve with Stopcock & Two outlet Diverter

KICKSPACE 500, 600, V & 800

Installation Instructions and User Guide Thermostatic Recessed Dual Control Shower Valve

EFG ENERGY OPTIMISING SYSTEMS

INSTALLATION INSTRUCTION

Owner s Manual. Installation Details Owner s Information Warranty. 25L and 50L Electric Storage Water Heater

Installation Instructions and User Guide. Heritage Fixed Riser Kit. Models Covered: STC03 (Chrome) STA03 (Gold)

PERFORMANCE SHOWER PRODUCTS

Link-Up. Solid Fuel Association Guide to Central Heating.

Jetflush 4 Instruction Manual

Infra Red Thermostatic Wall Mixer

Electrician Installation Manual Icon 52 inch (132cm) Ceiling Fan

Related party disclosure: Technical Information Benchmark. 99 m² 336 kwh/m² per year 73 kg/m² per year

Transcription:

Space Saver New easy guide Connecting your Space Saver to a central heating system Issue 001 February 2018 ENGLISH UK IRL SmithsEP.co.uk Issue 001 - February 2018 SmithsEP.co.uk 1

Introduction This document is intended as an easy step-by-step guide to connecting your Smith s Space Saver plinth heater to your central heating system. It is aimed at those who are typically replacing a panel radiator or connecting to an existing central heating system. We hope it offers an invaluable resource to both professional installers and competent DIY ers alike. It will show you what heating systems are suitable for Space Saver, how to connect your unit to your existing system and help you get the best performance from your heater. This guide is intended to be read in conjunction with the Installation and User Guide provided with the product. We would stress that should you have any doubts regarding connection of our product to the central heating system you should consult a professional. Details of a local qualified installer can be found by contacting the Chartered Institute of Plumbing and Heating Engineering on 01708 472791 or visit their Website on www.ciphe.org.uk How does it work? Space Saver is connected to your existing central heating system pipework. Hot water passes through the unit and transfers the heat to aluminium fins. Cooler air is drawn in by an electric fan and heated as it passes through the aluminium fins, and then is gently blown back into the room via a low level grille. This not only gives a more even temperature spread, but will heat the room up in less than half the time of a traditional panel radiator. Cold air in Warm air out Cold air in Space Saver Dual models have an additional electric heating element to allow the unit to produce heat when the central heating system is switched off. Only models designated 12V are suitable for use in bathrooms and other high humidity areas. Space Saver grille - available in a large range of finishes 2 SmithsEP.co.uk Issue 001 - February 2018

Is your central heating system suitable? Nearly all central heating systems, including micro-bore, are suitable for the installation of a Space Saver heater. The only exception is a one pipe system (see diagram below), which has been little used since the sixties and early seventies. The diagrams below and on page 4 will help you identify your central heating system. One pipe open vented Gravity fed pumped heating cylinder feed & expansion tank pump Two pipe open vented Gravity fed pumped heating cylinder feed & expansion tank pump Two pipe open vented Fully pumped feed & expansion tank cylinder pump Issue 001 - February 2018 SmithsEP.co.uk 3

Is your central heating system suitable? Nearly all central heating systems, including micro-bore, are suitable for the installation of a Space Saver heater. The only exception is a one pipe system (see diagram below), which has been little used since the sixties and early seventies. The diagrams below and on page 3 will help you identify your central heating system. Two pipe sealed system cylinder pump Expansion vessel If you have a sealed system or combination it s best to locate the pressure gauge and filling loop which are usually located next to each other. You will also need the manufacturer s recommended system pressure information for when you come to refill the system. Combination filling loop mains cold in Microbore Space Saver can be integrated into heating systems with Ø10mm microbore pipework but it is very important that the amount of microbore pipework used to include the Space Saver into the heating system is minimised, ideally to less than 3m. If the amount of microbore pipework is excessive the flow rate through the Space Saver may be compromised and the performance of the Space Saver maybe adversely affected reducing the heat output of the product. It may also prevent the automatic thermostatic may not switch the fan on as the water temperature in the product fails to achieve the required 38 C. Please refer to the current edition of either the CIBSE Guide B1 Heating or CIPHE Plumbing Engineering Services Design Guide. 4 SmithsEP.co.uk Issue 001 - February 2018

Connecting your Space Saver to the central heating system Read this guide in conjunction with the Installation & User Guide provided with the product. Copies are available from the download centre on www.smithsep.co.uk or by calling us on 01245 324560. Before beginning please ensure you read all the safety and guidance notes within the Installation & User Guide. You should now have identified your heating system and whether it is suitable to incorporate a Space Saver heater. Your next step is to drain the system of water (see page 6) to enable you to cut into the pipe work at the proposed location of the Space Saver unit. Positioning Space Saver Space Saver is primarily designed for installation in the space beneath kitchen/utility room units, behind the plinth. However, Spacer Saver can also be installed in other locations such as stair risers and built-in furniture. Only 12 volt models can be used in bathrooms and other high humidity areas. Space Saver can be fitted directly onto the floor (diag A) or raised in a plinth (diag B). If raised, the product should be placed on a stable level platform. Cut the plinth as described in the Installation & User Guide. A B Plinth Plinth Positioning the Pipework The heater connects to your existing heating system s flow and return pipes. If you are unsure what these pipes are, or of the system you have, then refer to the system diagrams on pages 3 of this guide. System flow and return pipes to the heater must, where possible, be at the same level or below the heater s own flow and return pipes. This will reduce the risk of air traps. If this cannot be avoided, ensure that a finger vent is fitted allowing any air traps to be vented. Positioning the Fused Spur Now is a good time to work out the best position for the electrical fused spur. Safety regulations require that the fused spur must not be positioned directly above the heater and be easily accessible once installation is complete. Be careful, when placing inside a cupboard, that objects can t hit the switch accidentally. Electrical work should only be carried out by a qualified electrician in compliance with building regulations. Issue 001 - February 2018 SmithsEP.co.uk 5

Connecting your Space Saver to the central heating system Draining the system 1. Turn off the electric isolation switch normally adjacent to the. 2. If you have an open vented system turn off the mains water supply to the feed and expansion tank. The stopcock valve is normally located near the tank. If there is no stopcock valve tie the ball cock (float arm) in the up position using a batten to keep the valve closed. For combination s and system s, please refer to manufacturers instructions for draining and refilling. 5. Close the bleed valves and the water will continue to drain from the system. 6. Lastly drain any inverted pipe loops. Pipes are often run through ceiling voids and drop down walls to individual radiators. This is called an inverted pipe loop. Each loop should have its own draincock. It is only necessary to drain the inverted loop. inverted pipe loop 3. Attach a length of hose to the main draincock, usually located on the return pipe near the. Place the other end of the hose to a suitable drain. Open the draincock with a key or adjustable spanner and the system will start to drain. draincock Connecting the Space Saver 1. Cut and prepare the pipework and connect the heater as detailed in the Installation & User Guide. 4. Water may be held in the radiators due to the vacuum that is created. To release the water, work from the highest radiator down and open the bleed valves on each radiator to release the trapped air. 6 SmithsEP.co.uk Issue 001 - February 2018

Refilling the heating system IMPORTANT We recommend the use of central heating protectors as these provide long term protection of domestic central heating systems against internal corrosion. If your system has been treated with a central heating protector you should refer to the manufacturer s instructions for topping up and refilling your heating system. Information regarding previous treatment may be with your heating system installation and user guides, on a label near the or if fitted, on a label near the feed and expansion tank. Untreated systems must be thoroughly cleansed and flushed before treating as existing debris can damage the installation. If in doubt seek professional advice. 1. First check that you have closed all the draincocks and radiator bleed valves. 2. Turn on the supply to your system. If you have an open vented system turn on the valve to the expansion tanks or untie the ballcock. If you have a sealed system your system feed will most likely be located at the. 3. In an open vented system the water will stop filling the expansion tank when the system is full. In a sealed system the system is full when you reach the required pressure as recommended by your manufacturer. 4. As the system fills up air will be trapped in the top of the radiators. You will have to bleed each one, this time starting from the lowest level radiator and working upward. You may also have to bleed the circulating pump. 5. As you bleed the air out of the radiators it will need to be replaced by water. In an open vented system this will be fed automatically, but in a sealed system you will have to let more water in to keep the pressure at the correct level. It s a good idea to have two people during this procedure, one bleeding the radiators and one topping up the water. 6. Check all draincocks and bleed valves for signs of leakage and tighten if necessary. Completing the Installation 1. Refer to the Installation and User Guide to complete the commissioning of your Space Saver. Balancing the central heating system The balancing of the system should be carried out by a qualified person; the following notes are for guidance only. The balance of your central heating should not be affected by installing a Space Saver as part of the system. If however you get little or no heat output from the Space Saver heater it may be that the balance of the system was not correct prior to the installation. Prior to balancing, you should: a. Check the power supply is switched ON. b. If fitted, ensure the room thermostat is calling for heat. c. Increase the water temperature. The purpose of balancing is to achieve equal heat distribution and heat output across all heat emitters (radiators, etc) on your central heating system. Generally, upstairs radiators get hotter quickest because is lighter than cold water and so naturally rises. Consequently, radiators that are farthest from the, and those at the lowest level, will need a larger volume of. To achieve the correct balance, it is necessary to restrict the flow of water through each radiator by adjusting the lockshield valve. For best results, the temperature of water leaving the radiator should be 10% lower than that of the water entering the radiator. This will ensure maximum efficiency and give a longer life to the. The Space Saver within your system does not need balancing but you should ensure the isolating valves supplied are fully open. lockshield valve thermostatic or wheelhead valve Issue 001 - February 2018 SmithsEP.co.uk 7

Happy to help Smith s Environmental Products Ltd is one of the leading manufacturers of heating and cooling products in the UK. We are committed to achieving the highest standards and our faith is supported by a free five year parts and labour guarantee with every product. Our customer service is second to none and we are happy to offer any help and guidance that you might need. Stockists All products are available nationally from Builders Merchants, Plumbers Merchants, Heating Equipment Distributors and Kitchen Equipment Distributors. In the event of difficulty, please contact us or visit our website SmithsEP.co.uk for details of your nearest stockist. Information and advice Full technical specifications and list prices is available to download from our website or in hard copy from our office. Also available on our website are price lists, individual product data sheets, installation & user guides, where to buy, who to contact and a media centre. Alternatively contact our office 9.00am to 5.00pm Monday to Friday. To view the full product information download the datasheet at: www.smithsep.co.uk For product information, customer services or sales support call us on +44 (0) 1245 324900 For the Republic of Ireland, contact MT Agencies on 01 864 3363 Sales: sales@smithsep.co.uk General information: info@smithsep.co.uk Smith s Environmental Products Ltd Blackall Industrial Estate, South Woodham Ferrers, Chelmsford, Essex CM3 5UW SmithsEP.co.uk @SmithsEP_UK #ThinkSmiths Issue 001 February 2018 As part our commitment to continuous improvement Smith s Environmental Products may change the specifications of its products without prior notification or public announcement. All descriptions, illustrations, drawings and specifications in this publication present only general particulars and shall not form part of any contract. All dimensions are in mm unless otherwise stated. Smith s, providing comfort for the built environment 8 SmithsEP.co.uk Issue 001 - February 2018