Electrical Program. Electrical Laws & Rules. Electrical RCW WAC B. Permits Inspections Access Description Directions Comments.

Similar documents
CHAPTER 14 ELECTRICAL CODE

Electrical Tech Note 107

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

National Electrical Code

Informational Bulletin on Mobile office Units Prepared by Mark Hilbert May 17, 2017

CONTINUING EDUCATION FOR OREGON ELECTRICIANS. AMERICAN ELECTRICAL INSTITUTE PO Box Spokane, WA

Chapter 1 General... 5

Bulletin An application for inspection not required Rule 2-005

WIRING AND PROTECTION

ELECTRIC and NEON SIGN STANDARDS. By Randy Wright RKW CONSULTING

Brown University Revised June 29, 2012 Facilities Design & Construction Standards SECTION ELECTRICAL DESIGN CRITERIA

TABLE OF CONTENTS CHAPTER 1 GENERAL RULES CHAPTER 2 WIRING AND PROTECTION... 51

Definitions; contractors licensed by Board; examination; posting license, etc.

TOM BURNS, PLANNING DIRECTOR

TABLE OF CONTENTS CHAPTER 5 SPECIAL OCCUPANCIES CHAPTER 1 GENERAL RULES... 19

NEC Requirements for Standby Power Systems. New England Building Officials Education Association Annual Conference October 5, 2015

Chapter 1 General...9 Article 100 Definitions...11 Article 100 Questions Article 110 Requirements for Electrical Installations...

TABLE OF CONTENTS CHAPTER 2 WIRING AND PROTECTION CHAPTER 1 GENERAL RULES... 19

ELECTRICAL CURRICULA OUTLINE CORE CURRICULUM 2015

FIRE ALARM: BY OTHERS, IF REQUIRED.

Florida Senate SB 982 By Senator Bennett

Iowa Electrical Examining Board Division of the State Fire Marshal s Office

FIRE ALARM: BY OTHERS, IF REQUIRED.

Electrical Code Incorporating the 2014 International Building Code as amended

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

APPENDIX - L INTERNATIONAL RESIDENTIAL CODE ELECTRICAL

.4 Do complete installation in accordance with latest Electrical Bulletins of the local inspection authority.

Town of Cicero Local Code Amendments

ELECTRICAL INSPECTION ACT REGULATIONS

2009 ELECTRICAL CODE REQUIREMENTS

Rocky Mountain Chapter IAEI Annual Meeting Northglenn, CO March 18-19, 2004

RESIDENTIAL OVER. 4. Would it be permissible to hard- wire the dishwasher in question 3? If so, under what conditions?

STATEWIDE CAREER/TECHNICAL EDUCATION COURSE ARTICULATION REVIEW MINUTES

CITY OF LOS ANGELES LARUCP ELECTRICAL PLAN CHECK LIST

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL

IEC and NCCER Mapping for Year 1

Spring Test 6 due 04/26/2013

2011 and 2014 National Electrical Code Changes Residential Only

Fee $15 Course: NEC Changes 5 This course is valid for these credentials: Credential Description Cred Code Credit Hours

C A L I F O R N I A E N E R G Y C O M M I S S I O N

Electrical Safety Program

Building Division 201 SE 3 rd STREET (Second Floor) OCALA, FL Phone: (352) BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS

SECTION LIGHTING CONTROLS

ORDINANCE NO

Troy's Home Inspection Services LLC

ORDINANCE NO. _ THE PEOPLE OF THE CITY OF LOS ANGELES DO ORDAIN AS FOLLOWS:

Recent Revisions and Proposed Key Changes to Fire Code

Muskogee Public Schools. Lockout/Tagout. Program

GROUP SR SPECIAL (ASSISTED SELF-PRESERVATION) OCCUPANCIES

Dwelling unit feeder/service conductor calculations

INSPECTION REQUIREMENTS: ENERGY CODE LIGHTING & ELECTRICAL NON-RESIDENTIAL

"This is only the scope of work for the project. For more information, interested parties should contact Procurement at

EasyWire Between Joists Installation Instructions

SUMMARY: Policy Title: Electrical Safety Work Practice Program. Policy Number: UNIV-EHS 430 Policy Approved: January 2014

Proposed Amendments To The 2008 National Electrical Code

Table of Contents CHAPTER 10 ADMINISTRATIVE RULES FOR CERTIFICATION OF CHILD CARE FACILITIES FIRE STANDARDS FOR FAMILY CHILD CARE HOME

ONE- AND TWO-FAMILY DWELLING ELECTRICAL CODE HANDOUT (2015 Michigan Residential Code Effective February 8, 2016)

Photovoltaic (Solar) Array Installation Guide

Subcontract Agreement No.

ENGROSSED SUBSTITUTE HOUSE BILL State of Washington 60th Legislature 2007 Regular Session

Carbon Monoxide Detectors in New and Existing Buildings

SIGNIFICANT CHANGES TO MINOR WORK AND ORDINARY MAINTENANCE

This fee schedule is for Building Inspection Fees only.

SUBJECT: Effective Date: Procedure Number:

Bold items are particular to the City of Euless

NATIONAL TRAINING BOARD (ELECTRICIAN) REGULATIONS 2008 BR 54/2008 NATIONAL OCCUPATIONAL CERTIFICATION ACT :38

SECTION 915 CARBON MONOXIDE DETECTION

Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

Schedule of Approved Fees

Construction Codes Advisory Council

SECTION 2 NEC REFERENCES SECTION 1 LOW-VOLTAGE AND POWER- LIMITED SYSTEMS...1. CHAPTER 1 GENERAL Introduction...35

GROUP SR SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES

Princeton Joint Unified School District Invitation for Bid Installation of District-Wide Lighting Occupancy Sensors

Exhibit A. Mechnical, Plumbing, and Electrical Plan Check and Inspection Fees. Total Cost Per Unit FEE TYPES MECHANICAL PERMIT FEES

RESIDENTIAL ELECTRICAL INSPECTIONS CHECKLISTS

Electrical Design Guidelines Table of Contents

Installation Instructions

2017 NEC Presented by: Russ LeBlanc

COMMERCIAL (IBC) FIRE ALARM SUBMITTAL GUIDE

First Published in the Wichita Eagle on DELINEATED 10/02/2010 ORDINANCE NO.

CITY OF LOS ANGELES ELECTRICAL PLAN CHECK CORRECTION LIST

"This is only the scope of work for the project. For more information, interested parties should contact Procurement at

AN ORDINANCE TO AMEND CHAPTER 7-BUILDING REGULATIONS, ARTICLE 1-UNIFORM CONSTRUCTION CODE, SECTION 7-2 -FEES TO ESTABLISH A NEW FEE SCHEDULE

SERIES & NO. SMI SUBJECT: SAFE CONSIDERATIONS FOR AN APPLICATION OF SPECIAL ELECTRICAL SYSTEMS

Building & Safety PERMIT APPLICATION

Commercial, Manufacturing and Industrial: Office Areas.18/total sq. ft. Agricultural buildings, detached garages, and accessory.15/total sq. ft.

CHAPTER 15 PART IV NATIONAL ELECTRICAL CODE, 2017

SAN JOAQUIN COUNTY ELECTRICAL PLAN CHECK CORRECTION SHEET (209) FAX (209)

$ Each additional variance per petition. $ All Other Zoning Districts: One variance per petition

10606 Bloomfield Ave Santa Fe Springs, CA USA

IMPORTANT NOTICE BUILDERS AND CONTRACTORS WORKING IN NORTH RICHLAND HILLS, TEXAS. June 17th, 2016

Code Compliance Report

***DRAFT - NOT FOR FILING***

Excellent Home Inspection Services, LLC

SECTION IDENTIFICATION FOR ELECTRICAL SYSTEMS

Please make yourselves familiar with the changes and start implementing them immediately so you can be better prepared for June 30 th, 2018.

Exhibit J. Subcontract Agreement No.

Entry Level Assessment Blueprint Electrical Construction Technology

CONNECTICUT. Downloaded

City of Calabasas Building and Safety Division Fee Schedule

Transcription:

Electrical Laws & Rules Licensing Electrical Work Scope Administrator Duties Certification Supervision RCW 19.28 WAC 296-46B Permits Inspections Access Description Directions Comments Electrical Program

RCW-The Law Revised Code of Washington 19.28 ELECTRICIANS AND ELECTRICAL INSTALLATIONS WAC-The Rules Washington Administrative Code 296-46B ELECTRICAL SAFETY STANDARDS, ADMINISTRATION, AND INSTALLATION

History Pre 1985 All HVAC work must be done by a licensed electrical contractor. Appropriate certifications were: 01, 02, 06, 07. 1985 Electrical Board policy allows a registered HVAC contractor to install one thermostat in 1- and 2- family dwellings.

History 1985-1997 Revisions to Electrical Policy 85-04 allow registered HVAC/R contractors to install low voltage, Class 2 control circuit cables exclusively for HVAC/R equipment in buildings that do not exceed three floors.

History 1998-1999 Illegal policies abolished by the Electrical Board. HVAC industry chooses to create the Limited Energy HVAC Technician (06A) Effective March 15, 1999

History 1999 Original (06A) scope-of-work limited to: Components within HVAC equipment both line and low voltage. Low voltage control systems in buildings that do not exceed three floors.

History 2001 HVAC/R Definitions added The HVAC/R scope-of-work expanded to allow the HVAC industry to disconnect and reconnect line voltage supply whips not over six feet in length. (Allows equipment to be replaced like-inkind)

History 2003 HVAC/R Scope Expands Some line voltage replacement work in external disconnecting means. Repair and replacement of components regardless of number of floors in building. Included work on equipment operating above 600 volts.

History 2003 HVAC/R 06B Scope HVAC/R restricted (06B) created. One year (2000 hours) instead of two years experience required. Reduced training under supervision (1000 hours) before testing and working alone. Reduced scope (1Ø, 250 V, 120 A) and easier examinations.

History 2006 HVAC/R 06A Scope Added Scope This specialty may: Install a bonding conductor for metal gas piping to an existing accessible grounding electrode conductor or grounding electrode only when terminations can be made external to electrical panelboards, switchboards, or other distribution equipment.

Scope of Work WAC 296-46B-920(f) Both 06A and 06B may: Install low voltage Class 2 HVAC wiring in all residential occupancies. Install, repair, replace, maintain line voltage components within HVAC/R equipment. Install, repair, replace, maintain line voltage components within HVAC/R external disconnects, not in a panelboard or motor control center.

Scope of Work WAC 296-46B-920(f) Both 06A and 06B may: Install short sections (not systems) of raceway for physical protection or access (sleeves) of LV cables. Repair, replace, maintain supply whips not over 6 feet, with same size wire. No restrictions on replacement wiring method.

Scope of Work WAC 296-46B-920(f) Both 06A and 06B may NOT: Install line voltage controllers or disconnects. Install, repair, replace, maintain: o Non-HVAC/R controls o Stand-alone line voltage heating equipment o Raceway systems o Services, feeders or branch circuits. (Conductors between split system outdoor and indoor unit is a branch circuit)

Scope of Work WAC 296-46B-920(f) Both 06A and 06B may NOT: Install panelboards, switchboards, motor control centers, or disconnects external to the HVAC/R unit.

Scope of Work WAC 296-46B-920(f) 06A specialty: Not limited by voltage, phase, or amperage. Install HVAC/refrigeration Class 2 lowvoltage control circuit wiring-components in non-residential occupancies that have no more than 3 stories above grade.

Scope of Work WAC 296-46B-920(f) 06A specialty: No 3 story limit for install of HVAC/R Class 2 low- voltage control circuit wiring/components if: It does not pass between stories, and done in previously occupied space (i.e. tenant improvement work)

Scope of Work WAC 296-46B-920(f) 06A specialty: Repair, replace, and maintain HVAC/R Class 2 low-voltage control circuit wiringcomponents in all occupancies regardless of the number of floors. No work in hazardous locations except inside the HVAC/R equipment.

Scope of Work WAC 296-46B-920(f) 06B specialty: Limited to HVAC/R systems 1Ø, 250 volt, 120 amps maximum. Limited in non-residential occupancies to no more than 3 stories above grade. No work in raceway systems. No work in hazardous locations.

RCW 19.28.041-Contractor License Required It is unlawful for any person, firm, partnership, corporation, or other entity to engage in, conduct, or carry on the business of installing or maintaining wires or equipment to convey electric current, or installing or maintaining equipment to be operated by electric current as it pertains to the electrical industry, without having an unrevoked, unsuspended, and unexpired electrical contractor license, issued by the department in accordance with this chapter. (Certified electricians are not allowed to do side jobs unless they are a licensed electrical contractor)

RCW 19.28.061-Administrator Duties and Requirements Duties: Available during working hours. Ensure all work complies with state electrical laws and rules. Ensure proper electrical safety procedures are used. Ensure all electrical labels, permits, and licenses are used. Ensure all corrections are completed. Notify department within 10 days of leaving a contractor. 20

Yellow Stripe Specialty certificates o No supervision required o Limited work scope Green Stripe General certificates o No supervision required o Unlimited work scope Red Stripe Training certificates o Supervision required o Work scope limited by supervising electrician

RCW 19.28.161-Certificates of Competency and Trainees Supervision means under the control and on the same jobsite as the certified electrician 75% of each working day. Ratio for specialty work: 1 certified electrician to 2 trainees. See WAC 296-46B-100 Definitions of supervision and jobsite. 22

WAC 296-46B-100 Definitions Supervision for the purpose of supervising electrical trainees, means that the appropriately certified supervising electrician is on the same jobsite as the trainee being supervised. The trainee is not considered to be on the same jobsite if the supervising electrician and the trainee are working: (a) In separate buildings at a single address (e.g. a campus, multi-building industrial complex, multi-building apartment complex, etc.) except for a single family residence; or (b) On an outdoor project (e.g. irrigation system, farm, street lighting, traffic signalization, etc.) where the trainee is more than 1,000 from the supervising electrician or where the trainee is more than 200 from the supervising electrician and out of sight. Jobsite means a specific worksite having a single address or specific physical location (e.g. a single family residence, a building, a structure, a marina, an individual apartment building with a specific address, etc.)

Training certificate renewal: Electrical trainees are required to have 48 hours of basic classroom education to renew. http://www.lni.wa.gov/tradeslicensing/electrical/licenseexamed/education/ TraineeClasses/default.asp

WAC 296-46B-945 Qualifying for examination (1)-(13) All details about qualifying for journeyman, specialty, and master electrician examinations have been grouped into this article. Qualifying experience for specialty examinations is detailed in Table 945-1. 25

Table 945-1 Experience Hours Specialty Minimum Hours of Work Experience Required to be Eligible for (4) (5) (9) Examination Minimum Hours of Work Experience Required for Certification (8) Residential certificate (02) 4,000 (3) 4,000 Pump and irrigation certificate (03) 4,000 (3) 4,000 Domestic well certificate (03A) 720 (1) (2) 2,000 (6) Signs certificate (04) 4,000 (3) 4,000 Limited energy system certificate (06) 4,000 (3) 4,000 HVAC/refrigeration certificate (06A) 4,000 (3) 4,000 (7) HVAC/refrigeration-restricted certificate (06B) 1,000 (1)(2) 2,000 (6) Nonresidential maintenance certificate (07) 4,000 (3) 4,000 Nonresidential lighting maintenance and lighting retrofit 720 (1)(2) 2,000 (6) certificate (07A) Residential maintenance certificate (07B) 720 (1)(2) 2,000 (6) Restricted nonresidential maintenance certificate (07C) 1,000 1)(2) 2,000 (6) Appliance repair certificate (07D) 720 (1)(2) 2,000 (6) Equipment repair certificate (07E) 1,000 (1)(2) 2,000 (6) Door, gate, and similar systems certificate (10) 720 (1)(2) 2,000 (6)

WAC 296-46B-970 Continuing education courses (1)-(21) All requirements for continuing education for administrators, master electricians, and electricians are located in this article. Certificate renewal requires: 8 hours per year X 3 years = 24 hours 8 hours must be National Electrical Code update 4 hours must be RCW/WAC update Remaining can be any approved industry related class 27

RCW 19.28.101-Corrections- Inspections-Entry-Permit Fees Corrections must be completed within 15 days, unless additional time is requested and approved. Inspectors may disconnect dangerous or unsafe wiring and must post notice. Illegal to reconnect until repaired and approved. 28

WAC 296-46B-901 Permitsresponsibility Electrical work permits must be obtained and posted at the job site prior to beginning the installation or alteration. 29

WAC 296-46B-901 Permitsrequirements for Class A work exempt from permits: the like-inkind replacement of lamps; a single set of fuses; a single battery smaller than 150 amp hour; contactors, relays, timers, starters, circuit boards, or similar control components; one household appliance; circuit breakers; single family residential luminaires; a maximum of five snap switches, dimmers, receptacle outlets, thermostats, heating elements, luminaire ballasts with an exact same ballast; component(s) of electric signs, outline lighting, or skeleton neon tubing when replaced onsite by an appropriate electrical contractor and when the sign, outline lighting or skeleton neon tubing electrical system is not modified; ten horsepower or smaller motor. 30

WAC 296-46B-100 Like in kind "Like-in-kind" means having similar characteristics such as voltage requirement, current draw, circuit overcurrent and short circuit characteristics, and function within the system and being in the same location. Likein-kind also includes any equipment component authorized by the manufacturer as a suitable component replacement part.

WAC 296-46B-908 Class B random electrical inspection Only sold to contractors, healthcare or large commercial/industrial facilities w/certified electricians. Validate the label online and affix on jobsite before beginning work. Sold in blocks of twenty. 32

WAC 296-46B-908 Class B random electrical inspection Like-in-kind replacement of: A motor over 10 HP. Internal wiring of a furnace, AC unit, or refrigeration unit. A furnace not over 240V, 100A. (Not a boiler). An AC, heat pump, or refrigeration unit not over 240V, 40A. Installation of devices or wiring for Class 2 or 3 thermostat. 33

Our Website www.lni.wa.gov Questions? Email ElectricalProgram@lni.wa.gov

WAC 296-46B-100 General definitions. HVAC/refrigeration specific definitions: (a) "HVAC/refrigeration" means heating, ventilation, air conditioning, and refrigeration. (b) "HVAC/refrigeration component" means electrical power and limited energy components within the "HVAC/refrigeration system," including, but not limited to: Pumps, compressors, motors, heating coils, controls, switches, thermostats, humidistats, low-voltage damper controls, outdoor sensing controls, outside air dampers, stand-alone duct smoke detectors, air monitoring devices, zone control valves and equipment for monitoring of HVAC/refrigeration control panels and low-voltage connections. This definition excludes equipment and components of non-"hvac/refrigeration control systems." (c) "HVAC/refrigeration control panel" means an enclosed, manufactured assembly of electrical components designed specifically for the control of a HVAC/refrigeration system. Line voltage equipment that has low voltage, NEC Class 2 control or monitoring components incidental to the designed purpose of the equipment is not an HVAC/refrigeration control panel (e.g., combination starters). (d) "HVAC/refrigeration control system" means a network system regulating and/or monitoring a HVAC/refrigeration system. Equipment of a HVAC/refrigeration control system includes, but is not limited to: Control panels, data centers, relays, contactors, sensors, and cables related to the monitoring and control of a HVAC/refrigeration system(s). (e) "HVAC/refrigeration equipment" means the central unit primary to the function of the "HVAC/refrigeration system." HVAC/refrigeration includes, but is not limited to: Heat pumps, swamp coolers, furnaces, compressor packages, and boilers. (f) "HVAC/refrigeration system" means a system of HVAC/refrigeration: Wiring, equipment, and components integrated to generate, deliver, or control heated, cooled, filtered, refrigerated, or conditioned air. This definition excludes non-hvac/refrigeration control systems (e.g., fire alarm systems, intercom systems, building energy management systems, and similar non-hvac/refrigeration systems) Jobsite means a specific worksite having a single address or specific physical location (e.g. a single family residence, a building, a structure, a marina, an individual apartment building with a specific address, etc.) Supervision for the purpose of supervising electrical trainees, means that the appropriately certified supervising electrician is on the same jobsite as the trainee being supervised. The trainee is not considered to be on the same jobsite if the supervising electrician and the trainee are working: (a) In separate buildings at a single address (e.g. a campus, multi-building industrial complex, multi-building apartment complex, etc.) except for a single family residence; or (b) On an outdoor project (e.g. irrigation system, farm, street lighting, traffic signalization, etc.) where the trainee is more than 1,000 from the supervising electrician or where the trainee is more than 200 from the supervising electrician and out of sight. WAC 296-46B-920 Electrical/telecommunications license/certificate types and scope of work. (2)(f) HVAC/refrigeration systems: (i) See WAC 296-46B-100 for specific HVAC/refrigeration definitions. (ii) For the purposes of this section when a component is replaced, the replacement must be like-in-kind or made using the equipment manufacturer's authorized replacement component. (iii) The HVAC/refrigeration specialties described in (f)(v) and (vi) of this subsection may: (A) Install HVAC/refrigeration: Telecommunications, Class 2 low-voltage control circuit wiring/components in all residential occupancies; (B) Install, repair, replace, and maintain line voltage components within HVAC/refrigeration equipment. Such line voltage components include product illumination luminaires installed within and powered from the HVAC/refrigeration system (e.g., reach-in beverage coolers, frozen food cases, produce cases, etc.) and new or replaced factory authorized accessories such as internally mounted outlets; (C) Repair, replace, or maintain the internal components of the HVAC/refrigeration equipment disconnecting means or controller so long as the disconnecting means or controller is not located within a motor control center or panelboard; (D) Install, repair, replace, and maintain short sections of raceway to provide physical protection for lowvoltage cables. For the purposes of this section a short section cannot mechanically interconnect two devices, junction boxes, or other equipment or components; and

(E) Repair, replace, or maintain line voltage flexible supply whips not over six feet in length, provided there are no modifications to the characteristics of the branch circuit/feeder load being supplied by the whip. There is no limitation on the whip raceway method (e.g., metallic replaced by nonmetallic). (iv) The HVAC/refrigeration specialties described in (f)(v) and (vi) of this subsection may not: (A) Install line voltage controllers or disconnect switches external to HVAC/refrigeration equipment; (B) Install, repair, replace, or maintain: Integrated building control systems, other than HVAC/refrigeration systems; Single stand-alone line voltage equipment or components (e.g., heat cable, wall heaters, radiant panel heaters, baseboard heaters, contactors, motor starters, and similar equipment) unless the equipment or component: Is exclusively controlled by the HVAC/refrigeration system and requires the additional external connection to a mechanical system(s) (e.g., connection to water piping, gas piping, refrigerant system, ducting for the HVAC/refrigeration system, gas fireplace flume, ventilating systems, etc. (i.e., as in the ducting connection to a bathroom fan)). The external connection of the equipment/component to the mechanical system must be required as an integral component allowing the operation of the HVAC/refrigeration system; or Contains a HVAC/refrigeration mechanical system(s) (e.g., water piping, gas piping, refrigerant system, etc.) within the equipment (e.g., "through-the-wall" air conditioning units, self-contained refrigeration equipment, etc.); Luminaires that serve as a building or structure lighting source, even if mechanically connected to a HVAC/refrigeration system (e.g., troffer luminaire used as a return air device, lighting within a walk-in cooler/freezer used for personnel illumination); Raceway/conduit systems; Line voltage: Service, feeder, or branch circuit conductors. However, if a structure's feeder/branch circuit supplies HVAC/refrigeration equipment containing a supplementary overcurrent protection device(s), this specialty may install the conductors from the supplementary overcurrent device(s) to the supplemental HVAC/refrigeration equipment if the supplementary overcurrent device and the HVAC/refrigeration equipment being supplied are located within sight of each other; or Panelboards, switchboards, or motor control centers external to HVAC/refrigeration system. (v) HVAC/refrigeration (06A): (A) This specialty is not limited by voltage, phase, or amperage. (B) No unsupervised electrical trainee can install, repair, replace, or maintain any part of a HVAC/refrigeration system that contains any circuit rated over 600 volts whether the circuit is energized or deenergized. (C) This specialty may: Install HVAC/refrigeration: Telecommunications, Class 2 low-voltage control circuit wiring/components in other than residential occupancies: That have no more than three stories on/above grade; or Regardless of the number of stories above grade if the installation: Does not pass between stories; Is made in a previously occupied and wired space; and Is restricted to the HVAC/refrigeration system; Repair, replace, and maintain HVAC/refrigeration: Telecommunications, Class 2 low-voltage control circuit wiring/components in all occupancies regardless of the number of stories on/above grade. Install a bonding conductor for metal gas piping to an existing accessible grounding electrode conductor or grounding electrode only when terminations can be made external to electrical panelboards, switchboards, or other distribution equipment. (D) This specialty may not install, repair, replace, or maintain: Any electrical wiring governed under article(s) 500, 501, 502, 503, 504, 505, 510, 511, 513, 514, 515, or 516 NEC (i.e., classified locations) located outside the HVAC/refrigeration equipment. (vi) HVAC/refrigeration restricted (06B): (A) This specialty may not perform any electrical work where the primary electrical power connection to the HVAC/refrigeration system exceeds: 250 volts, single phase, or 120 amps. (B) This specialty may install, repair, replace, or maintain HVAC/refrigeration: Telecommunications, Class 2 low-voltage control circuit wiring/components in other than residential occupancies that have no more than three stories on/above grade. (C) This specialty may not install, repair, replace, or maintain: The allowed telecommunications/low-voltage HVAC/refrigeration wiring in a conduit/raceway system; or Any electrical work governed under article(s) 500, 501, 502, 503, 504, 505, 510, 511, 513, 514, 515, or 516 NEC (i.e., classified locations).