RF Admittance Technology FACTS

Similar documents
LS 1 Empty Belt Detector RF Admittance PXL1-XX02 PNL1-A. LS 2 Plugged Chute Detector RF Admittance PXL1-XX50 PNL1-A LS 3

Installation and Operating Instructions

Oxygen Deficiency Monitor and Oxygen Analyzers. Oxygen Sensors for 0-25% and ppm

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

Instrumentation and Controls Group

Electronic Pressure Digest. Pressure and Temperature Transmitters

Ultrasonic Point Level Switches

Electronic Flow Switches

Ultrasonic Switches. Features & Benefits

Quick Start Guide For the

Product Guide LEVEL MEASUREMENT PRESSURE MEASUREMENT TEMPERATURE MEASUREMENT FACTORY AUTOMATION

Dependable Solutions for Gas Detection

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

TABLE OF CONTENTS Flow Detect 1000 Specifications 3 Description 4 Principle of Operation 4 Detection Through Walls 4 Sensing Beam Shape 4 Installation

Instruction Manual. Princo Model L3522. Point Level Controllers with LEVEL SENTRY. Rev 2, June 2013

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

Rosemount 2100 Series

Oxygen Deficiency Monitor and Oxygen Analyzers. Oxygen Sensors for 0-25% and ppm

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

Continuous and Point Level Measurement. Radiometric Sensors for Liquid and Solid Level Measurement

E C H O T E L C O N T A C T U L T R A S O U N D

Sensall Sapphire. Thermo MeasureTech ULTRASONIC POINT LEVEL SYSTEM

Model D12-IR. Digital Gas Transmitter...

C1N & C2N SERIES Fluid heating for light industrial applications

ue short form catalog Leaders in Safety, Alarm & emergency Shutdown

Cimco Series 21. Series 21 - Specifications INDEX. Description. Operational Specification 2

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

Centro-Matic Automated Lubrication Systems System Controls

ULTIMA X5000. MSAX5000.com

Sitron s CF Line of Flow Switch Monitors

Ronan Model X96S Series Density System

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Cabinet Cooler Systems

S5000 Gas Monitor. GMS5000.com

Level Measurement. Point level measurement Capacitance switches. Pointek CLS100. Overview. Configuration

Ronan Model X90 Series Point Level Monitor

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Introduction to Flow Switch

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

Level Measurement. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.

Pre-March 2016 Design - Click to be redirected to newer SBS-H2 design SBS-H2. Hydrogen Gas Detector Kit

B.D.I. The B.D.I. (Burst Disc Indicator) Alarm System is designed for use with Continental Disc

Model Q45P/R. ph/orp Monitor...

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100 5/9. Overview. Configuration

FUNCTIONAL SAFETY MANUAL. Gassonic Observer-H and Observer-i Ultrasonic Gas Leak Detector

Sanitary Pressure Transmitter

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

Sapphire ULTRASONIC POINT LEVEL SYSTEM

T500 Elite - Hotbus Plant Wide Monitoring System for Bucket Elevators & Conveyors

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Dräger Polytron 8310 IR Detection of flammable gases and vapour

FLT93 Installation, Operation and Troubleshooting Guide

Model Q45P/R. ph/orp Monitor...

Dräger Polytron 8000 Stationary gas detector (EC)

Quick Start Manual July pointek CLS100

SAFETY MANUAL. Multispectrum IR Flame Detector X3301

Ronan Model X96S Series Weighing System

FUNCTIONAL SAFETY MANUAL

Sensor Interface Module Installation/Operation Instructions

BDI-FLX B URST SY STE M BENEFITS BDI-FLX AVAILABLE FOR INDUSTRIAL AND SANITARY APPLICATIONS

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Dräger Polytron 5100 EC Detection of toxic gases and vapors

EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR

Dräger Polytron 5700 IR Detection of flammable gases and vapours

The LC-100 s valved manifold controls the flow of air and allows the LC-100 to accurately monitor liquid levels with a minimal air usage.

CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

C1N Series - Light Industrial Heaters Tankless Water Heating Solutions

Liquid Helium Level Instruments

SAFETY MANUAL. Intelligent Sensors for H 2 S Gas Applications

SAFETY MANUAL. X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors

Keltech SNA-Series - Safety Shower Heaters Tankless Water Heating Solutions

I.S. Interfaces. for the Process Industry. display. i.s. interface. isolation. temperature. universal

Discontinued. SN Series - Safety Shower Heaters Tankless Water Heating Solutions. Standard Equipment. Construction. Code Compliance and Certifications

Transmitter Series. Intelligent Transmitter Series Tailor the Measurement to Your Needs INGOLD

SAFETY MANUAL. IR5000 Open Path Hydrocarbon Gas Monitoring System

SULLAIR DESICCANT DRYERS

TECHNICAL DATA OBSOLETE

SAFETY MANAGER SC Ensure safety, simplify operations and reduce lifecycle costs

SAFETY MANUAL. PointWatch Eclipse Infrared Hydrocarbon Gas Detector Safety Certified Model PIRECL

Capital Controls SERIES 70CV3000 CHLOROMATIC VALVE

I.S. Interfaces. for the Process Industry. display. i.s. interface. isolation. temperature. universal

The Clark-Reliance Corporation TWIP System Installation and Maintenance Instructions - Form E112 -

SBS-H2. Hydrogen Gas Detector Kit. For battery charging rooms and other areas where hydrogen gas may be present

POINTEK ULS 200 ULTRASONIC LEVEL SWITCH

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Remote Relay Module (RRM)

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Dräger Polytron 8700 IR Detection of flammable gases and vapors

CAPITAL CONTROLS SERIES WP70CV3 GAS FEEDERS

VIEW. Matters. Magnetic Level Indicators Series. with. indicator. The. 200º viewing angle. 200º viewing angle

Industrial Grade Gas Detection

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

SNA-SKID Series - Preassembled Safety Shower Heater Skid Tankless Water Heating Solutions

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

RED1. Technical Support And Installation Manual. Models ST, E1, E2, E3, E4, and 420. Approved

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Transcription:

RF Admittance Technology FACTS Each year RF Admittance is the most purchased technology offered in electronic point level products Versatile technology, well proven in a wide range of applications in solid, liquid, and slurry conditions, unequalled in differentiating the interface between insulating and conducting liquids Cote-Shield technology eliminates false alarms due to coatings on the sensing element Robust technology is capable of handling environmental extremes from cryogenic to 2,000ºF and process pressures from vacuum to 10,000 psi. Broad selection of industrially designed sensors are available for applications ranging from light powders to rocks, water to corrosive acids, with sanitary models for the pharmaceutical, biomedical, and food and beverage industries Sensors can be easily shortened or lengthened in the field No calibration products with automatic verify and certify test features When evaluating instrumentation for purchase there are some basic considerations that should be taken into account before making a decision. For an electronic point level switch, careful consideration should be given to which product technology will provide the highest reliability. It only stands to reason that often times manufacturers will make the claim that their technology and products are best suited for you. We suggest that you focus on the facts and don't let yourself become distracted by their claims. Listed are some facts to take into account when considering whether or not the RF Admittance technology and Drexelbrook products are best suited for your particular needs. Maintenance requirements are drastically reduced due to no moving parts, eliminating the need for excessive spare parts inventory, thus improving cost of ownership

DREXELBROOK FACTS Over 45 years of application and product experience for both point and continuous level applications Recognized as the worldwide leader of exceptional RF Admittance level products Leader in innovative and award winning designs using RF Admittance technology and proprietary sensors RF Admittance point level products represent best-in-class products in their particular product group Selecting the right supplier is another important part of the evaluation process. Once again, we will give you the facts and you can make the decision. We hope after your review, that you feel we have given you enough good reasons to choose Drexelbrook as your supplier. Every other point level technology we offer delivers the highest value in their product class We have a well established worldwide network of independent representatives and distributors that are ready to serve you with an average of over 30 years experience with Drexelbrook Level is our only business, which allows us to focus entirely on the level needs of the many markets we serve and the needs of those customers Drexelbrook has an installed base of over 2 million electronic point level switches, from the easiest to the most difficult applications, in every industrial sector Drexelbrook consistently earns high rankings for electronic point level and other technologies (Control Magazine Readers Choice Awards)

INTELLIPOINT RF Admittance Point Level Switch Our BEST and most versatile point level switch for liquids, slurries, interface and granular applications. The Intellipoint is suitable for extreme applications, temperatures from cryogenic to 2,000ºF and pressure from vacuum to 10,000 psi. Sensors are designed for everything from light powders to rocks, slurries, and sanitary requirements. Drexelbrook's exclusive Cote- Shield circuitry eliminates false trips even with heavy coatings on the sensing element. The Intellipoint automatically calibrates itself; simply install the sensor in your vessel and connect power. An AutoVerify self-check circuit continuously monitors the complete instrument to validate that the switch is functioning properly. A watchdog circuit monitors the AutoVerify function, and indicates a fault if the AutoVerify circuit fails. The manual Certify not only checks the function of the switch and the control loop, but also checks the AutoVerify self-test circuits to make sure that they are also working properly. All these features make the Intellipoint the most versatile point level switch on the market. ThePoint RF Admittance Point Level Switch ThePoint RF Admittance switch offers PREMIUM features at an economical price. ThePoint has the Auto-calibration feature; simply install in the vessel and power it up. No messing with potentiometers or initializing with buttons or magnets. ThePoint microprocessor-based electronic unit calibrates itself. ThePoint has no moving parts to wear out or hang up. This, along with Drexelbrook's Cote-Shield circuitry, eliminates the maintenance required with mechanical switches. These features make ThePoint the ideal choice to replace high maintenance, less robust, point level products. ThePoint provides reliable level switch operation for a wide variety of point level applications needs. Z-Tron III RF Admittance Point Level Switch The Z-Tron III is an ECONOMICAL, general-purpose level switch for many liquids, slurries, and granular applications. The one-piece unit (electronics integrally mounted to the sensing element) is easily installed through a 3/4 inch NPT coupling. Calibration is attained with a potentiometer adjustment. Drexelbrook's Cote-Shield circuitry enables the Z-Tron III to ignore coatings on the sensing element. The Z-Tron III provides reliable point level operation for many of your point level switch applications at an economical price. Auto-Calibration Auto-Ranging power supply Dual compartment housing Relay or current outputs Integral or remote mount electronics AutoVerify and Certify test features No moving parts for maintenance free operation Applications from cryogenic to 2,000ºF, vacuum to 10,000 psi 3A/sanitary sensors available Optional SIL 1 and SIL 2 compliant models 3 year warranty Auto-Calibration Push-button selectable manual calibration and high sensitivity for special applications Auto-Ranging power supply Relay or current outputs Integral Integral or remote mount electronics No moving parts for maintenance free operation Applications from cryogenic to 500ºF, vacuum to 1,000 psi 3A/sanitary sensors available 2 year warranty One-time calibration with a potentiometer adjustment Relay outputs No moving parts for maintenance-free operation Applications from cryogenic to 250ºF at 200 psi 1-year warranty

PRODUCT SPECIFICATIONS INTELLIPOINT RF ThePoint Z-Tron III Modes of Operation: High and Low Level Modes of Operation: High and Low Level Modes of Operation: High and Low Level Repeatability: 2mm (0.08 inches) Repeatability: 2mm (0.08 inches) Repeatability: 2mm (0.08 inches) conductive liquids conductive liquids conductive liquids Response Time: Less than 1 second Response Time: Less than 1 second Response Time: Less than 1 second Ambient Temperature: -30 to 70ºC (-28 to Ambient Temperature: -30 to 70ºC Ambient Temperature: -40 to 70ºC 158ºF) KEMA, -40 to 70ºC (-40 to 158ºF) (-28 to 158ºF) KEMA, -40 to 70ºC (-28 to 158ºF) FM, CSA (-40 to 158ºF) FM, CSA Indicators LEDs: Green lit = Normal, Indicators LEDs: Line Power Unit - Green Indicators LEDs: Line Power Unit - Green not lit = Alarm Power, Red Relay 1 Alarm, Red Relay 2 Alarm Power, Red Relay Alarm Supply Voltage: 120+25 VAC, 50/60 Hz Loop Power - Green Power - Red Alarm Loop Power - Green Power - Red Alarm (standard unit), 230+25 VAC, 50/60 Hz Supply Voltage: Line Power Unit 85-250 Supply Voltage: Line Power Unit 19-250 (optional), 15 to 30 VDC (optional) VAC, 21-100 VDC, Auto-detecting without VAC, 18-200 VDC, Auto-detecting without Power Consumption: 1 watt maximum jumpers DC to 400 Hz jumpers (50/60Hz) Output: DPDT relay Loop Power Unit 13 to 30 VDC Loop Power Unit 13 to 30 VDC Approvals: UL / CUL / 508 general purpose, Power Consumption: 2 watts maximum Power Consumption: 2 watts maximum CE Mark Output: Line Power Unit (2) DPDT relay Output: Line Power Unit DPDT relay Housing: NEMA 4X, explosion proof Loop Power Unit 8mA / 16mA Loop Power Unit 8mA / 16mA MTTF (Mean Time To Failure): 110 years Approvals: FM, CSA, ATEX, CE Mark (loop power unit) Housing: NEMA 4X, explosion proof Approvals: FM, CSA, ATEX, GOST, CEPEL, CE Mark Housing: NEMA 4X, explosion proof Wireless Interface Solution Products AMETEK Drexelbrook wireless interface utilizes 902-928 MHz ISM band spread spectrum frequency hopping technology to guarantee a license-free, interference-free link between remote devices and the control room. Costly cable and conduit runs are eliminated and replaced with a maintenance-free, reliable wireless solution. Applications include monitoring of level, pressure, flow, and switching of discrete outputs and alarms. Any product that provides a 4 to 20 ma or discrete output can take advantage of this low cost solution that replaces expensive cable and conduit. Products are available for point-to-point and multi-point-to-point installations, plus twoway communication. DREXELBROOK 205 Keith Valley Road Horsham PA 19044 U.S.A. U.S.A. Sales: 800-553-9092 24-Hour Service: 800-527-6297 International Support: 215-674-1234 Domestic Sales Fax: 215-956-3815 or 215-956-3824 International Sales Fax: 215-672-8981 Main Fax: 215-674-2731 E-mail: drexelbrook.info@ametek.com 2007, by AMETEK, Inc. Printed in the U.S.A. 5M707PDF (270010) Drexelbrook #420-0001-298