compact office 24V compact office 24V Lux

Similar documents
compact office 24V compact office 24V Lux

ECO-IR 360C NT. Presence detector. Art. Nr Bedienungsanleitung 2. Notice d utilisation 22. Installation manual 42

PräsenzLight PräsenzLight PräsenzLight A.. PräsenzLight A..

PresenceLight 180 PresenceLight 360

PresenceLight 180A-KNX.. PresenceLight 360A-KNX.. PresenceLight 180B-KNX.. PresenceLight 360B-KNX..

1. Product characteristics 4 2. Safety 5 3. Proper use 5 4. Operation 6

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Function description. Channel A light. Motion detector

3. Intended use. 4. Function. 1. Product characteristics. 2. Safety. Functional description. Channel A light. Motion detector

Motion detector themova P360 KNX UP WH themova P360 KNX UP GR

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Motion detector

2. Safety. 1. Product characteristics. 3. Proper use. 4. Operation. Function description. Presence detector

2. Safety. 1. Product characteristics. 3. Proper use. 4. Operation. Function description. Presence detector

2. Safety. 4. Function

1. Basic safety information 3 2. Proper use 3

KNX/EIB - Product database - Application description

Product and Applications Description

1. Basic safety information 3 2. Proper use 3

IP 55 (category II) IP 54 (category II) 4. Connection. 1. Basic safety information. 2. Proper use. 5. Installation. 3. Description.

User Manual 120/240/300 Outdoor Motion Detector

Infrascan Passive Infrared Motion Sensor Surface-Mount 753SSR Series. Installation Instructions

Detailed operating instructions

FR-A180 FR-A360. Occupancy detector. Use

GE Lighting. Lighting Controls. DALI Digital Lighting Controls

Detailed operating instructions

Connections, displays and operating elements C D E G H. Installing the control unit

UP 258E11 OPTISENS OFFICE

1. Basic safety information 3 2. Proper use 3

OPERATING INSTRUCTIONS

DIMAX DIMAX D GB F I E NL. Installation and operating instructions Universal dimmer DIMAX 532. Minimum DIMAX 532.

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

DIMAX DIMAX 534 plus D GB F I E nl. Installation and operating instructions Universal dimmer. DIMAX 534 plus

PRESENCE DETECTOR. PD-C360i/8 mini KNX PD-C360i/12 mini KNX / 13 7 REMOTE CONTROL PRESENCE DETECTOR

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features

0701 CO Light, HVAC, Monitoring, Brightness

Ceiling PIR HS presence detector. Product Guide. Overview. Features

Operating instructions

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

11,9. Ordering data. Max. cable length sensor head 1 basicdim ILD lx 150 lx m 1

PIR movement and presence detectors 10 A

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor

GMA4100-DP. Control Panel. Operation Manual. Worldwide Supplier of Gas Detection Solutions

LED Compatible Daylight Harvesting and Motion Sensor System

SCHMIDT LED Measured Value Display MD Instructions for Use

luxcontrol DALI basicdim DGC Product Manual

Push Button Electronic Timer. 31VETR3 Series. Installation Instructions

Use of the application program

luxcontrol lighting control system basicdim basicdim ILD Compact control module with ambient light sensor and motion sensor

Tri-level Control HF Sensor

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Analogue Dimming Microwave Presence/Absence Detector

11,1 30. Ordering data

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

Automatic switch attachment Standard Installation Instructions

Push Button Electronic Timer. 31VETR Series. Installation Instructions

HF Motion Sensor Introduction

PRODUCT DATA AND INSTALLATION SHEET MWS5-SA STAND ALONE MINIATURE CEILING MOUNTED MICROWAVE PRESENCE DETECTOR

The two type sensors are innovative and active motion dimmable LED drivers or ballasts.

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Devices for Special Applications

II SL. Installation Guide. VOLTEX IMS64-2 Dual output indoor flush mount PIR motion detector IMS64-2

EBMHS (standard & slim-line PSU)

SMART BASIC BASIC-IR DAYLIGHT

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

User manual. ABB i-bus EIB. Zone Terminal MT/S Intelligent Installation System ABB STOTZ-KONTAKT

Danfoss gas detection unit Type GD Heavy Duty

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

, ,

Premium Version Tri-level Dimming Control

Carbon Monoxide (CO) Gas Detector March 15 GCO 300

Integrated PIR detectors

Tri-level Control HF Sensor

MWS3A-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

Eco-sensors - PIR. Catalogue number(s): / / Use. 1. Use Technical characteristics (continued)

EBDSPIR-PRM-2CH, EBDSPIR-PRM-2CH-NC

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

SWITCHLITE MRE SLD MAN SWITCHLITE MRE SLD IP55

C-Bus PIR Occupancy Sensor. Installation Instructions 5751L

EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC

NEWS THEBEN THEBEN 2

VITMR-EBDSPIR-PRM. PIR Presence/Absence Detector IR with Ceiling Rose. Product Guide. Overview. Features

MWS3 Ceiling Mount Microwave Occupancy Detector

Introduction. Dimming Function MC003V (Standard Version) MC003V R (Reinforced Version)

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Rev KNX Technical Reference Manual Busch Präsenz tech 6131/ /11-500

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features

PPAD-C-230V. Ceiling PIR presence/absence detector. Product Guide. Overview. Features

Busch-Watchdog presence. Overview and applications of presence detectors.

MWS6-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

L / -014L / -015L

IP65 High Bay Dual Sense Sensor

M1000 Alarm Annunciator

Technical Manual. Level Alarm Unit CARLA & WIDS

LOGIC MODULE EX-22 For lighting control with automatic regulation of light level

FLAME AMPLIFIER MODULE 3001

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.

Instructions for the fan motor control system, SILVER C

Direct Dim Microwave Presence/Absence Detector

Transcription:

Presence detector compact office 24V compact office 24V Lux Art. Nr. 201 4 000 Art. Nr. 201 4 001 D F GB E I NL S N FIN DK Bedienungsanleitung 2 Notice d utilisation 22 Installation manual 42 Manual de instrucciones 62 Istruzioni per l'uso 82 Gebruikershandleiding 102 Bruksanvisning 122 Bruksanvisning 142 Käyttöohje 162 Betjeningsvejledning 182 1103019405 / 04.2010 Theben HTS

English Installation manual Table of contents Presence detector compact office 24V compact office 24V Lux 1. Safety.................................................. 43 2. Function and performance characteristics....................... 44 3. Fitting and connection...................................... 45 4. Start-up................................................. 48 5. Parallel circuit operation.................................... 52 6. Use of the user remote control clic............................ 53 7. Test Operation............................................ 54 8. Technical specifications..................................... 55 9. Warranty declaration....................................... 57 10. Troubleshooting.......................................... 58 42

GB Thank you for purchasing an Theben HTS presence detector and putting your trust in us. 1. Safety Familiarise yourself with the compact office 24V (Lux) before assembly and start-up by reading this operating instructions. IMPORTANT! The unit requires no maintenance. Opening the unit or inserting foreign bodies into it will invalidate the warranty. Proper use The presence detector serves exclusively for the purpose contractually agreed between the manufacturer and the user. Any other use is regarded as improper. The manufacturer is not responsible for any resulting damage. 43

2. Function and performance characteristics The presence detector compact office 24V (Lux) detects persons within a room on account of slightest movements. Simultaneously, its light sensor measures the brightness in the room and compares it to the preset brightness threshold. Two relays (compact office 24V) or one relay (compact office 24V Lux) serve as switching outputs. The presence detector compact office 24V (Lux) is used preferably in offices, small passageways and ancillary rooms. A mechanical safety lock protects the detector against unauthorised removal. The switching contact A «Light» switches on the lighting in case of presence and insufficient brightness, and off in case of absence or sufficient brightness. Switching contact «Light»: potential-free relay Adjustable brightness threshold and switch-off delay Suitable for fluorescent and compact energy saving lamps as wells as for halogen and incandescent lamps Pulse function for staircase lighting timer QuickSet plus service remote control (optionally) clic user remote control (optionally) The switching contact B «Presence» (compact office 24V only) controls heating, ventilation and air-conditioning systems. The contact closes in case of presence, a switch-on delay allows a delayed switching on. 44

The contact can also be used for room surveillance purposes. Using reduced sensitivity, it only responds on very distinct movements. Switching contact «Presence»: potential-free relay Adjustable switch-on delay and switch-off delay Surveillance function GB The analog output 0-10V (compact office 24V Lux only) provides the brightness measured by the detector s light sensor as an analog signal. The output can be used like a light sensor and functions independently from the presence detector. Analog output 0-10V Linear or logarithmic output of brightness 3. Fitting and connection 3.1 Presence detection The ideal mounting height is 2,0-3,0m. The sensitivity of the detector decreases with increasing mounting height. In order to ensure proper detection of persons, the detector requires an unobstructed view of the persons. Office equipment, plants, suspended lamps etc. may affect the presence detection (shading). 45

M height Seated persons Walking persons 2,0m 9 m 2 3,0m x 3,0m 20 m 2 4,5m x 4,5m ± 0,5m 2,5m 16 m 2 4,0m x 4,0m 36 m 2 6,0m x 6,0m ± 0,5m 3,0m 20 m 2 4,5m x 4,5m 49 m 2 7,0m x 7,0m ± 1,0m 3,5m --- 64 m 2 8,0m x 8,0m ± 1,0m Detection range (mounting height 3,0m) 3 2 1 0.8 Lux o 0 m 3.5 3 2 1 0 1 2 3 3.5 seated persons walking persons 3,5 3 2 1 0 1 2 3 3,5 46

3.2 Light measurement The detector measures artificial light and daylight reflected directly beneath the detector (beam width approx. ± 30 ). GB The mounting location is used as the reference for the lighting levels. With indirect lighting, the artificial light at the detector s mounting location should not exceed 2000 Lux (Brightness value > 2000 Lux). 3.3 Connection A concealed housing should be used for flush-mounted fitting of the presence detector. A surface frame is available for surface mounting. 24V= ~ 24V= ~ + - compact power 24V See the technical data + - compact power 24V Lux A1 A2 B1 B2 A1 A2 0-10V + - 0-10V 47

4. Start-up The detectors are supplied ready for operation with a factory setting of recommended standard values. The QuickSet plus service remote control for starting-up the system is optionally available. With the remote control all potentiometer values can be set from a distance. 4.1 Settings for switching contact A «Light» Potentiometer Brightness threshold LUX Scale Transfer zones (no working area) approx. 2 Working areas (office, conference room) approx. 4 Activities requiring good visibility (laboratory, drawing, etc.) > 5 Deactivation of brightness measurement «on» Depending on the installation location, natural light intensity, furniture, reflection characteristics of the room and the furniture it may be necessary to correct the settings by 1-2 steps on the scale. For ease of setting up, we recommend the service remote control QuickSet plus. 48

Switch-off delay time Transfer areas approx. 5min. Working areas approx. 10min. In the range between 2-15min the switch-off delay varies according to its self-learning behavior. The set values <2min or >15min remain fixed. «Pulse»: staircase lighting timer control (0.5sec. on / 10sec. off ) GB DIP switch Light measurement: adaptive or fixed hysteresis auto : the light measurement is in adaptive mode. fix : if the lighting is continuously overridden by a superordinate logic, the adaptive mode can be deactivated. auto 0-10V lin 4.2 Settings for analog output 0-10V (compact office 24V Lux only) fix 0-10V log Linear or logarithmic output of brightness 0-10V lin : linear output of brightness 0-10V log : logarithmic output of brightness; improved resolution at low lux values 49

4.3 Settings for switching output B «Presence» (compact office 24V only) Switch-off delay time for presence The pre-set values remain unchanged (no self-learning effect). Switch-on delay time for presence In case of presence, the contact does not close before the set switch-on delay has elapsed. 0 = Contact closes immediately in case of presence. Room surveillance function; the contact closes only in case of distinct movements (effective protection against false alarms). 10s 50

4.4 Behaviour on switching on Whenever the sensor module is plugged onto the power module or the unit is energised, the detector goes through tree phases which are indicated by an LED. 1. Start-up phase (30sec) LED flashes every second, both contacts are closed (light and presence on) In case of absence, both contacts open after 30sec. 2. Service phase (10min) The Light contact reacts instantaneously on brightness in order to check the brightness threshold. If the brightness is insufficient the lighting is switched on (LED on),and if the brightness is sufficient the lighting is switched off (LED off). The service phase can be terminated earlier by actuating the clic user remote control. 3. Operation The detector is ready for operation (LED off). GB 51

5. Parallel circuit operation The relay outputs of a number of detectors can be connected in parallel circuit operation. This enables coverage of large and irregularly shaped rooms such as corridors, underground parkings e.g. A parallel connection of 0-10V analogue outputs is not permissible. The total permissible load does not increase. Presence detection and brightness measurement by all detectors together. The brightness threshold value and switch-off delay time must be adjusted individually for each detector. The user remote control clic can only be used subject to certain restrictions (see section 6). 24V= ~ 24V= ~ + - compact power 24V + - compact power 24V + - compact power 24V Lux + - compact power 24V Lux A1 A2 B1 B2 A1 A2 B1 B2 A1 A2 0-10V + - A1 A2 0-10V + - 0-10V See the technical data 52

6. Use of the user remote control clic a Please note that the user remote control clic can only be used to limited extent with a number of detectors connected in parallel. GB Amount of devices One device Two devices Three and more devices Group adresses clic Group addresses freely selectable. See user instructions for user remote control clic fore more details Device 1: Group adress A or C Device 2: Group adress B or D clic: Group adresses A+B or C+D The ON and OFF commands switch the lighting on and off respectively. The user remote control clic cannot be used! 53

7. Test Operation The test mode serves to check the presence detection and the wiring. 7.1 Setting the test mode with DIP-Switch Set DIP switch to «Test». 1. Start-up phase (30sec) Both contacts are closed for 30sec. (LED 20s «on», 10s «off» ) 2. Test mode In case of movement (LED on), both contacts close. In case of absence (LED off), both contacts open after 10sec. NOTE: no brightness measurement. The detector remains permanently in the test mode. 7.2 Setting the test mode with QuickSet plus While setting the test mode with the service remote control QuickSet plus, the detector jumps the start-up phase and changes directly into the test mode. Test mode ceases automatically after 10 minutes. The detector performs a reset (see section 4.3). 54

8. Technical specifications Sensor module Detection range: horizontal vertical compact office 24V 360 120 Recommended mounting height (Mh) 2,0-3,0m Maximum range 6 x 6 m (Mh. 2.5m) 8 x 8 m (Mh 3.5m) Mixed light control Light measurement deactivated Switch off delay for light Short pulse Switch off delay for presence Switch on delay for presence Room surveillance Power modules ca. 10-1500Lux on 10sec. - 20min. 0.5sec. on / 10sec. off 10sec. - 120min. 0sec. - 10min. compact power 24V compact power 24V Lux Nominal voltage 24V AC/DC ± 20% Relay output A1, A2 for light Relais, potential free Type of contact 24V @ AC/DC ±20% potential-free micro-contact Switching capacity: minimal maximal 1V / 1mA *) 50W / 460VA GB *) A load of more than 60V or 100mA on the switching contact (max. 1.5W) changes its characteristics permanently; the minimum load specification of 1V/1mA can no longer be guaranteed. 55

Relay output B1, B2 for presence (compact power 24V only) Type of contact potential-free micro-contact Switching capacity: Analog output 0-10V (compact power 24V Lux only) Output voltage Load resistor Mixed light measurement minimum maximum Relay potential-free User remote control clic 907 0 515 56 24V @ 2Aµ, 230V~2Aµ 1V / 1mA *) 50W / 460VA 0-10V 0-10V DC > 10kΩ linear approx. 10-1500 Lux logarithmic approx. 10-5000 Lux Depth 40mm Diameter 48mm Mounting plate 70 x 70mm Screw terminals max. 2x 2.5mm2 Size of concealed housing (for flush-mounting) Dim. 1, (NIS,PMI) Ambient temperature 0-50 C Degree of protection IP 40 Article numbers compact office 24V 201 4 000 compact office 24V Lux 201 4 001 Surface frame for compact 907 0 514 Service remote control QuickSet plus 907 0 532

9. Warranty declaration Theben HTS presence detectors are manufactured and quality-tested with the utmost care using state-of-the-art technologies. Theben HTS therefore guarantees perfect function, provided the detectors are used as intended. However, should a defect occur, Theben HTS offers the following warranty within the scope of its General Terms and Conditions of Business: GB Please bear in mind the following points: The warranty period is 24 months, commencing from the manufacturing date. The warranty becomes null and void if you or third parties undertake alterations to the units. If the presence detector is connected to a software-controlled system, the warranty for this connection is only valid provided the stated interface specification is adhered to. We undertake to repair or replace as quickly as possible all supplied components which have become defective or unusable as a result of demonstrably bad material, faulty design or defective workmanship up to the expiry of the warranty period. Returns In the event of a warranty claim please send the unit together with the delivery note and a brief description of the fault to the dealer concerned. Industrial property rights The concept including hardware and software of these units is protected by copyright. 57

10. Troubleshooting Fault Lighting does not switch on or switches off in case of presence and darkness With persons present, the lighting is on although the brightness is sufficient Lighting does not switch off or switches on spontaneously in case of absence Lighting keeps switching on and off during the service phase Error blinking (4x per second) Cause Lux value setting is too low; Lighting was switched off manually with clic; Person is outside the detection range; Detection is disturbed by obstacles; Set switch-off delay setting is too short Lux value setting is too high; The lighting has been switched on manually with clic recently (wait for 30 min); Detector is in test mode Wait until the switch-off delay time has elapsed (self-learning effect); Disturbing heat sources within the detection range (heaters, incandescent lamp/ halogen lamp, moving objects (e.g. curtains due to open windows) Too much artificial light is falling on the detector, increase lux value. Set DIP switch to fix or reposition the detector. Failure during self test; Device not working! CE Declaration of Conformity This device complies with the protection regulations of the EMC directives 2004/108/EC and of the Low Voltage directive 2006/95/EC. 58

Dimensions compact office 24V, compact office 24V Lux 102,5 26 27 GB 48 76 66 33 78 40 46 102,5 15,5 Subject to change without prior notice. Errors and omissions excepted. 59

Theben AG Hohenbergstrasse 32, DE-72401 Haigerloch Tel. +49 (0) 74 74 692-0 Fax +49 (0) 74 74 692-150 Hotline Tel. +49 (0) 74 74 692-369 Fax +49 (0) 74 74 692-207 hotline@theben.de Switzerland Theben HTS AG Im Langhag 11, CH - 8307 Effretikon Tel. +41 (0)52 355 17 00 Fax +41 (0)52 355 17 01 www.theben-hts.ch Please find the contact addresses for additional countries on www.theben.de 60