Air Conditioner. user installation & manual manual. imagine the possibilities

Similar documents
INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

Air conditgioner. conditioner. User Installation manual/installation manual ARHVSD. future reference.

MAX INSTALLATION MANUAL AQN09VFUAGM AQN12VFUAGM AQN18VFUAGM AQN24VFUAGM AQN36VFUAGM

AS09HPAN AS12HPAN. Split-type Air Conditioner (Cooling and Heating)

INSTALLATION MANUAL Duct Type Series MH FECA

E S F I P D G DB A(1) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

Installation Instructions

INSTALLATION MANUAL MANUAL DE INSTALACIÓN MANUEL D INSTALLATION

TCB-DP22CUL. Drain Pump Kit. Model name : AIR CONDITIONER (SPLIT TYPE) Installation Manual. Installation Manual 2 Air Conditioner (Split type) English

Installation Instructions

Installation Instructions

INVERTER SPLIT - TYPE

Installation Manual. KS Series KS09 KS12 KS18 KS24 KS28. J3387_Kaden_Installer_Manual_ indd 1

DUCTLESS MINI-SPLIT INSTALLATION MANUAL COMFORT...BUILT TO LAST

Installation Instructions

Inverter Air Conditioner Installation Manual GIN 090/GIN 091 GIN 120/GIN 121 GIN 180/GIN 181 GIN 240/GIN 241

ROOM AIR CONDITIONER INSTALLATION MANUAL

Air conditioner. Installation manual AM777KN4DCH

SINGLE - ZONE Ductless Split System Heat Pumps Installation, Operation & Maintenance Manual

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

Installation Instructions

Dishwasher. Installation manual DW60M9990AP

1. BEFORE INSTALLATION

42PHW / 42PHQ 42PHQ...K

Installation Manual. WAS / WYS Series. For 9,000-36,000 BTU/hr Systems. Inverter+ and Inverter++ Models

Installation and Operation Manual. SVH Series. Inverter Single Zone Ductless Mini-Split SVH09SA-0 SVH09SA-1 SVH12SA-0 SVH12SA-1 SVH18SA-1 SVH24SA-1

Safety Precautions WARNING INSTALLING THE UNIT POWER SUPPLY LINE, FUSE OR CIRCUIT BREAKER

INSTALLATION MANUAL MANUAL DE INSTALACIÓN MANUALE D INSTALLAZIONE MANUAL DE INSTALAÇÃO MANUEL D INSTALLATION INSTALLATIONS-HANDBUCH

Installation Instructions

INSTALLATION. Glass Panel Doors (select models) CAUTION

Choosing the installation site. Installation. 07 Choosing the installation site

INSTALLATION MANUAL SPLIT TYPE ROOM AIR CONDITIONER (PART NO )

Installation Manual SPLIT-TYPE ROOM AIR CONDITIONER

DVC/DVH Series. Inverter Single Zone Ductless Mini-Split A-DVC/DVH 09SF A-DVC/DVH 12SF A-DVC/DVH 18SF A-DVC/DVH 24SF

INSTALLATION MANUAL COMFORT...BUILT TO LAST. 9,000, 12,000 and 18,000 BTU SINGLE-ZONE DUCTLESS MINI-SPLIT SYSTEM Heat Pump

SPLIT WALL-MOUNTED AIR CONDITIONER

Installation Instructions

Installation Manual Forest Series All Model Numbers

MULTI TYPE ROOM AIR CONDITIONERS INSTALLATION INSTRUCTIONS

Installation manual for room air conditioner

Installation Instructions

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

FLOOR TYPE AIR CONDITIONERS

1. BEFORE INSTALLATION

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO

Installation Manual. Aurora Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER CS

1. BEFORE INSTALLATION

QUICK CONNECT INSTALLATION MANUAL DUCTLESS MINI-SPLIT SYSTEM FOR MODELS: 2PAMSHQC12 2PAMSHQC18 2PAMSHQC24 2PAMSHQC36

Room Air Conditioner Service and Parts Manual

1. BEFORE INSTALLATION

Split Air Conditioner

Installation Manual. SYSPLIT WALL FLEXI Series SPLIT-TYPE ROOM AIR CONDITIONER

HEAT PUMP INSTALLATION MANUAL

OWNERS INSTRUCTION MANUAL

Installation Manual. Aurora Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER

Installation Manual. KSIF Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER

E XEIPI IO E KATA TA H

51AKB / 51 AKC OWNER S MANUAL

Air Conditioner. installation manual. imagine the possibilities

Installation Manual. Floor-Standing Type FLOOR-STANDING TYPE AIR CONDITIONER

Mini-Split Air Conditioner

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTIONS

Ductless Split Air Conditioner

1. BEFORE INSTALLATION

CEILING FAN OWNER'S MANUAL

Nortek Global HVAC, LLC

MULTI HEAT PUMP PANEL CONSOLE TYPE DUCTLESS INVERTER INDOOR UNIT INSTALLATION MANUAL. Models: CH09MCU230VI CH12MCU230VI CH18MCU230VI

Installation. Leveling

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

DLCSRA. INSTALLATION INSTRUCTIONS Outdoor Unit Ductless Split System Sizes 09 to 36 TABLE OF CONTENTS

Lifetime Limited Warranty

0RGHOV,QGRRU 8QLW MWM36Y3J 2XWGRRU 8QLW MRM36Y3J 11

51AKS I S O OWNER S MANUAL

INSTALLATION INSTRUCTIONS

Installation Manual Super-Slim Four-Way Cassette

INSTALLATION MANUAL. System Air Conditioner (Cooling and Heating) Cassette Type Series CH070CAV1 CH105CAV CH140CAV DB A(1) ENGLISH ESPAÑOL

Si REMOVAL PROCEDURE. 4.0/5.0/5.2/5.8/6.8/7.5 kw Class. Outdoor Unit Inverter Multi Type

Installation Manual. Oasis Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER CS

Installation. All about the. of your. Split Type Room Air Conditioner. Refer to Page 2 for table of contents.

Lifetime Limited Warranty

Glendale 52 in Ceiling Fan Owner's Manual. Glendale Ventilador de Techo de 1.32 m Manual del Propietario

1. BEFORE INSTALLATION

CEILING FAN OWNER'S MANUAL

CEILING FAN OWNER'S MANUAL

High Wall Split Air Conditioners 53QHCT KHCT

Refrigerator. Installation Guide. Free Standing Appliance

R410A SPLIT SERIES DC INVERTER

INSTALLATION MANUAL. R22 Split Series. Models FTY25GXV1 FTY35GXV1. Installation manual R22 Split series

CEILING FAN OWNER'S MANUAL

Air conditioner. Installation manual AC777KN4DCH

Installation Instructions

Table of Contents. Installation Manual. Accessories Safety Precautions Installation Overview Installation Diagram.

UltraV Series Outdoor Units

Installation Instructions

R32 INSTALLATION MANUAL ENGLISH AIR CONDITIONER (SPLIT TYPE) Indoor unit RAS-10PKVPG-E RAS-13PKVPG-E RAS-16PKVPG-E

Installation Instructions

INVERTER ONE-TWO/ONE-THREE/ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

Transcription:

ARFSSSBWK Series ARFSSSCUR AJ JNADCH Series Air Conditioner user installation & manual manual This manual is made with 100% recycled paper. imagine the possibilities Thank you for purchasing this Samsung product. To receive more complete service, please register your product at www.samsung.com/register EN ES FR DB68-04993A-00

Contents Safety precautions...2 Choosing the installation location...4 Accessories...5 Fixing the installation plate...6 Disassembling/Assembling the Cover panel for indoor unit installation...7 Connecting the wiring...9 Installing and connecting the assembly pipe of the indoor unit...11 Evacuating the indoor unit...12 Cutting or extending the pipe...12 Installing and connecting the condensate drain hose to indoor unit...14 Changing drain connection...15 Installing the indoor unit.................................................................................................. 16 Final check and trial operation...17 How to extend the power wiring...18 Sub PCB installation(optional)... 19 Safety precautions Carefully follow the precautions listed below because they are essential to guarantee the safety of the equipment. General information Carefully read the content of this manual before installing the air conditioner and store the manual in a safe place in order to be able to use it as reference after installation. For maximum safety, installers should always carefully read the following warnings. conditioner is sold or transferred. The manufacturer shall not be responsible for damages arising from the use of non compliant units. The manufacturer shall not be responsible for damage originating from unauthorized changes or the improper connection the warranty. The air conditioner should be used only for the applications for which it has been designed: the indoor unit is not suitable to be installed in areas used for laundry. Do not use the units if damaged. If problems occur, switch the unit off and disconnect it from the power supply. In order to help English-2

current laws. conditioner must be disposed of in authorized centers or returned to the retailer so that it can be disposed of correctly and safely. Installing the unit conditioner to the user. To help The air conditioner should be used only for the applications for which it has been designed : the indoor unit is not suitable to be installed in areas used for laundry. Our units must be installed in compliance with the spaces indicated in the installation manual to ensure either accessibility can be disassembled in conditions of complete safety either for people or things. Power supply line, fuse or circuit breaker compliance with current local safety standards. sufficient to ensure the operation of any other domestic appliance connected to the same electric lines. diagram included in the manual. English-3

Choosing the installation location Indoor unit Install the refrigerant piping length and the height difference of both indoor and outdoor units as indicated in the installation diagram. Out of the direct sunlight. or more or more You can select the direction of length 'H' meters maximum total pipe height Model L H AJ020 AJ024 The appearance of the unit may be different from the diagram depending on the model. English-4

Accessories The following accessories are supplied with the air conditioner: 01 Accessories in the indoor unit case INSTALLATION Tools required for installation General Tools Tools for test operations English-5

Fixing the installation plate the cable, pipe and hose pass to connect the indoor unit to the outdoor unit. Direction of pipe A D C D 1. Disassemble the cover panel as described in page 7~8. 2. Remove the Hanger plate from the indoor unit. B Screw 3. Determine the position of the pipe and drain hose hole as seen in the picture and drill the hole with an inner diameter of 2.56inch(65 mm) so that it slants slightly downwards. A D A D B C B C ] Model A B C D the direction of the pipe. 4. Fix the indoor unit. If you fix the indoor unit on a wall If you fix the indoor unit on a window frame If you fix the indoor unit on a gypsum board English-6

plate hanger. Assembling the hanger screw 01 INSTALLATION in the picture. Screw Disassembling/Assembling the Cover panel for indoor unit installation Please scan this QR code for detail video of indoor unit installation. In order to install the indoor unit, you must disassemble the cover panel first. Please proceed following instructions to disassemble and assemble the cover panel. Hooks (on the cover panel) may get damaged if you apply excessive force as you disassemble and assemble the cover panel. Please follow the following instructions. Removing the screws Cover panel is assembled on the bottom part of the indoor unit (as shown in the illustration) and it is fastened with screws. Remove the Cap screw first and unfasten the screws so that you can disassemble the cover panel. Cap Screw <Remove the Cap screw> Cover Panel English-7 <Unfasten the screw>

Disassembling/Assembling the Cover panel for indoor unit installation Removing the Cover panel (Before mounting the indoor unit) The bottom panel fits the main body using the side, center, and bottom hooks as shown. Unlock the side hooks first, and then unlock the center and bottom hooks. Check the location of the hooks before removing the cover panel. Location of the hooks on the central part Number and location of the hooks Side hooks Center hook Bottom hook Center hooks Bottom hooks Removing the hooks on the side For specific Hook location and quantity, please refer to cover panel with indicating arrows based on physical goods. Removing the hooks on the central part Caution (fragile) - Gently press the both side of the cover panel inwards ( ) and release the hooks on both sides( ). Caution (fragile) - Use both hands - Release each hook by pushing it up at an angle. Assembling the Cover panel (After mounting the indoor unit) To assemble the Cover panel, proceed in reverse order of disassembling. Use both hands for assembling and be extra careful not to damage the pipes and drain hose. Lock the side, center, and bottom hooks in this sequence. Tighten the bottom panel with the screws, and close the screw holes with their cap. <Lock the side hook> <Lock the bottom hook> <Fasten the screw> English-8 <Assemble the Cap screw>

Connecting the wiring If using a multi system, install as described in the installation manual supplied with the outdoor unit. Cable specification Model Power cable Interconnection cable Type GL supply, it must be incorporated in a wire with a contact opening of 01 INSTALLATION Connecting the cable Electrical work lb[. The terminal There is no ring There must be no space between the terminal and the screw when connected. is upside down. properly or there is a space between the screw and the ring terminal. Connect the air conditioner to grounding system before performing the electrical connection. cable is 98.4f 1. Extend the assembly cable if necessary. English-9

Connecting the wiring 2. Open the cover panel. 3. Remove the screw securing the connector cover. 4. Pass the assembly cable through the rear of the indoor unit and connect the assembly cable to terminals. (Refer to the picture below) 5. Pass the other end of the cable through the 2.56inch(65 mm) hole in the wall. 6. Close the connector cover by tightening the screw carefully. 7. Close the cover panel. 8. Remove the terminal board cover on the side of the outdoor unit. 9. Connect the cables to the terminals as seen in the picture. Indoor unit Indoor unit L1 L2 F1 F2 L1 L2 F1 F2 Outdoor unit Supply cable indoor units L1 L2 L1 L2 L1 L2 F1 F2 F1 F2 Outdoor unit 1 2 A 10. Connect the grounding conductor to the grounding terminals. 11. Close the terminal board cover by tightening the screw carefully. installation. English-10

Installing and connecting the assembly pipe of the indoor unit used. according to the exit position of the pipe when facing the wall: A B C Torque Outer Diameter f 1. Cut out the appropriate knock-out piece (A, B, C) on the rear of the ø indoor unit unless you connect the pipe directly from the rear. ø 2. Smooth the cut edges. 3. Remove the protection caps of the pipes and connect the assembly pipe to each pipe. Tighten the nuts first with your hands, and then with a torque wrench, applying the following torque: ø ø ø ø ø 01 INSTALLATION 4. Cut off the remaining foam insulation. 5. If necessary, bend the pipe to fit along the bottom of the indoor unit. Then pull it out through the appropriate hole. 6. Pass the pipe through the hole in the wall. English-11

Evacuating the indoor unit 1. Unscrew the caps at the end of each pipe. connect the pipes. may cause malfunction on the compressor. for product installation. caps Cutting or extending the pipe The length of the pipe can be: 1. Make sure that you have all the required tools (pipe cutter, reamer, flaring tool and pipe holder). 2. If you want to shorten the pipe, cut it using a pipe cutter, ensuring that the cut edge remains at 90 with the side of the pipe (see below examples of correct and incorrect cut edges). cutter Oblique Burr 3. To prevent a gas leak, remove all burrs at the cut edge of the pipe using a reamer. English-12

4. Put a flare nut slightly into the pipe and modify the flare. Flare 90 ± 2 B 45 ± 2 R 0.4~0.8 Outer Diameter (D) Depth (A) Flaring Size (B) ø ø ø ø 5. Check if you flared the pipe correctly (see examples of incorrectly flared pipes below). inch inch inch inch 01 INSTALLATION Correct Inclined Damaged Surface 6. Align the pipes to connect them easily. Tighten the flare nuts first with your hands, and then with a torque wrench, applying the following torque: Indoor outlet pipe Flare nut Connecting pipe Outer Diameter Torque f ø ø ø ø ø ø ø 7. For further details on how to connect to the outdoor unit and evacuate the air, refer to the installation manual supplied with the outdoor unit. English-13

Installing and connecting the condensate drain hose to indoor unit Indoor unit Drain hose slant upwards. The end of the drain hose water. The drain hose must not be bent. less Keep a clearance of at least drain hose and the ground. Ditch Do not place the end of the drain hose in a hollow. installation of the drain hose, pour water into whether the hose is well drained. Drain hose Drain hose Drain hose installation 4. Drain hose hole each side of connection by nch English-14

nch or more or more Drain hose drain hose Drain hose drain hose Shield downwards as seen in the picture. Drain hose Foam Insulation 01 INSTALLATION Changing drain connection Change the direction only when it is necessary. 1. Detach the rubber cap with the pliers. 2. Detach the drain hose by pulling it and turning to the left. Screw hole Screw 3. Insert the drain hose by fixing it with the screw into the groove of the drain hose and the outlet of the drain pan. 4. Attach the rubber cap with a screwdriver by turning it to the right until it fixes to the end of the groove. 5. Check for leakage on both side of the drain outlet. Drain hose Drain pan outlet Direction of the drained water English-15

Installing the indoor unit Then place the indoor unit on the installation plate. Insulation 1. To minimise condensation problems, wrap foam insulation (as shown in the figure) on a part without insulation on the end of the pipes. 2. Wind the pipe, assembly cable and drain hose with vinyl tape. 3. Place the bundle (the pipe, assembly cable and drain hose) in the lower part of the indoor unit carefully so it does not project from the rear of the indoor unit. 4. Hook the indoor unit to the installation plate and move the unit to the right and left until it is securely in place. an installation plate. 5. Wrap the rest of the pipe with vinyl tape. 6. Attach the pipe to the wall using clamps (optional). Installation plate Connecting wires Drain hose Connecting pipes English-16

Final check and trial operation ensure that the air conditioner operates correctly. Check the followings: 01 INSTALLATION 1. Press the Power button and check the following: The indicator on the indoor unit lights up. 2. Press the Mode button to select Cool or Heat mode. In Cool mode, use Temp hr. + or o In Heat mode, use Temp hr. + or o to conditioned space. 3. Press the Air swing button and check the following: 4. Press the Power button to stop the operation. place. English-17

How to extend the power wiring Items to prepare Tools Crimping pliers Insulation tape Spec Shape 1. As shown in the figure, peel off the shields from the rubber/wire of the power cable. - Peel off 20 mm of the wire shields of the tube installed already. 0.79(20) 0.79(20) 0.79(20) 2.36(60) 60 4.72(120) 7.09(180) 0.79(20) 2. Insert both sides of core wire of the power cable into the connection sleeve. 3. Using a compressor, compress the two points and flip it over and compress another two points in the same location. - The compression dimension should be 8.0. - After compressing it, pull both sides of the wire to make sure it is firmly pressed. Comp. dim. Compress it 4 times 4. Wrap it with the insulation tape twice and position your contraction tube in the middle of the insulation tape. 5. Apply heat to the contraction tube to contract it. Insulation tape Contraction tube 6. After tube contraction work is completed, wrap it with the insulation tape to finish. Insulation tape English-18

1(L) 2(N) F1 F2 1(L) 2(N) F1 F2 1(L) 2(N) F1 F2 Sub PCB installation(optional) 1. Turn the power off and take off the cover panel of the indoor unit. 2. Attach the Sub PCB to the Case Sub PCB. 3. Assemble the Case Sub PCB to the indoor unit. 01 INSTALLATION 4. Find the PCB wire, and connect the wire to the Sub PCB as seen in the picture. 5. Connect the wire(remote controller, central remote controller etc) to the Sub PCB. 1(L) 2(N) F1 F2 6. Assemble the Cover PCB and the front panel. If the Sub PCB is not installed, arrange the wire for multi system (connection) as shown in the illustration. Wire for multi system connection English-19