UV Flame Supervision System

Similar documents
LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

LAE10 LFE10. Use. Series 02

Flame Safeguards LFE10. Building Technologies HVAC Products

Flame Safeguards LFE10. Building Technologies HVAC Products

QRA2... QRA10... QRA53... QRA55... Flame Detectors. Siemens Building Technologies HVAC Products

LGA... Gas Burner Controls. Siemens Building Technologies Landis & Staefa Division

QRA10... QRA53... QRA55...

Flame detector. The QRA4.U is for use with the following types of burner control:

Flame detector. The QRA4.U is for use with the following types of burner control:

LGA... Gas Burner Controls. Siemens Building Technologies HVAC Products

QRA4.U. Flame Detector. Siemens Building Technologies HVAC Products

Flame detector. Building Technologies Division Infrastructure & Cities Sector

QRA10... QRA53... QRA55...

C Note! LGI16... Burner Controls. Building Technologies

QRA10... QRA53... QRA55...

LGA... Gas Burner Controls. Building Technologies Division

Infrared Flame Detectors

QRA10... QRA53... QRA55...

LOA2... LOA3... Oil Burner Controls. Siemens Building Technologies Landis & Staefa Division

LOA44.252A27. Oil Burner Control. Building Technologies HVAC Products

Infrared Flame Detectors

Use. Burner controls for use with forced draught gas or gas / oil burners of small to medium capacity in intermittent operation.

QRC1... Blue-flame Detectors. Siemens Building Technologies HVAC Products

LFL Series Burner Flame Safeguard Control

Use. The burner controls are certified to EN 230 and EN 298.

EUROBOX SERIES TYPES CM... SM... MM...

Oil Burner Controls LOA3... Building Technologies HVAC Products

LOA2... LOA3... Oil Burner Controls. Siemens Building Technologies HVAC Products

UV - flame detector dual fuel burners for intermittent burner operations

Basic unit with integrated air-fuel ratio control for forced draft burners

Burner Management System

Main Features. Functions. with automatic ignition and control functions for the heating and domestic hot water circuit

Oil Burner Controls LOA3... Building Technologies Division

LC3000 Level Controller Installation and Maintenance Instructions

Basic unit with integrated fuel-air ratio control for forced draft burners LMV Building Technologies Division

EURO-OIL SERIES TYPES G.. G../. OR.. OR../. F.. FR..

Burner controls. Building Technologies HVAC Products

EUROBOX SERIES TYPES CM...N SM...N MM...N

Oil Burner Controls LMO24... LMO44...

Oil Burner Controls LMO24... LMO44...

AUTOMATIC BURNER CONTROL SYSTEM SAFETY INFORMATION CONFORMITY

Forced draught gas burner

EUROFLAT SERIES TYPES C... S... M...

Gas burner automatic safety control MMI / 811.1

Basic Unit with integrated Fuel / Air Ratio Control for Forced Draft Burners LMV Building Technologies

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

Burner Management System

COMPACT FLAME CONTROLLER CFC 100

AUR300C. Advanced Ultraviolet Burner Controller

DMG 970. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners

Gas Burner Controls. Building Technologies HVAC Products

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

MICROFLAT SERIES TYPES C.../U T X

DKG 972. Gas Burner Safety Control. For 2-stage atmospheric gas burners

UV - flame detector KLC 10 for oil -, gas- and dual fuel burners for intermittent burner operations

Eclipse 90 UV Scanner Model A Version 1

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

Blue-flame Detectors

Burner Controls. Building Technologies HVAC Products

Burner Management System

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

for relative humidity and temperature

Use. Functions. Key function. Other functions

RAR... Photocell Detectors. Building Technologies Division

Building Technologies

Building Technologies Division

Distributed By: M&M Control Service, INC

Flame detector FD 2011 / FD 2012

Rules for Classification and Construction Additional Rules and Guidelines

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

Eclipse Self-Check UV Scanner

MBCE-110/230UV Flame Sensor Module

REA 105 Arc Protection Module. Operator s Manual

Product Range Overview

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller

DATASHEET. Burner control unit FDA 601x

Heating Controller for 2 heating circuits, d.h.w. and boiler, communicating

RVP331. Heating Controller for 2 heating circuits, d.h.w. and boiler. Building Technologies HVAC Products

for relative humidity and temperature

Safety. Operating instructions UV sensor UVS 10 DANGER WARNING. Contents CAUTION Edition Please read and keep in a safe place

Advanced Ultraviolet Burner Controller

Forced draught gas burner

Room Temperature Controller

PRODUCT: SEL-SV-MCQ-O5- K6 VERSION TECHNICAL SHEET 1/5 SAC

FLAME AMPLIFIER MODULE 3001

DKO 974/976 DKO 974 N/976 N. Oil Burner Safety Control

FlowJam S Ex. Bulk Flow Detection. Operating Instructions. SWR engineering Messtechnik GmbH

Old documentation - Only for your information! Product is not available anymore!

IRIS IP65 IRIS UNISCAN APPLICATION MANUAL

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

Fireye FLAME SCANNERS

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

RIELLO 40 GS/M SERIES

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

Immersion Temperature Controller

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products

Transcription:

7 783 UV Flame Supervision System DETACTOGYR LFE50 Series 02 ISO 9001 The LFE50 is a self-checking UV flame supervision system designed for use with continuously operating burners or for burners running with no interruption for more than 24 hours. Use General application notes One prerequisite for safe burner operation is a definitive flame signal, that is, a signal initiated by the burner flame alone. In the event of other influences or defects which simulate a flame signal, the flame supervision equipment must prevent any further burner operation. In order to detect a simulated flame signal in time, burner controls program automatically a functional test of the flame supervision circuit following each controlled shutdown (at the beginning of the startup sequence latest). The protection given by this test is the more effective the more frequently the burner is started and the shorter the actual operating period. With burners controlled in intermittent operation, this protection is given to a high degree. With this form of burner operation, the standards specify at least one controlled shutdown each 24-hour period - thus ensuring a minimum test frequency. Burners operating continuously must be monitored by self-checking flame supervision systems, such as DETACTOGYR. Field of use The self-checking flame supervision system DETACTOGYR, comprised of flame safeguard LFE50 and flame detector QRA50/51..., is designed for UV supervision. It can therefore be used for the supervision of oil burners with blue- or yellow-burning flames, for gas burners and dual-fuel burners. Automatic start-up and control of the burner is achieved using the control unit LEC1... (see data sheet 7761). The system is also suitable for use with manually operated burners. Prerequisite for the use of the DETACTOGYR system is sufficiently high UV radiation intensity at the viewing point of the UV detector. In combustion plants where heat generation must also be ensured in the event of failure of the flame supervision equipment, active redundancy circuitry can be easily achieved using two DETACTOGYR systems. Landis & Staefa CC1N7783E March 11, 1997 1/11

Mechanical design Flame safeguard LFE50 The flame safeguard is double-insulated and of plug-in design. It is suitable for mounting in any orientation into control cabinets or on control panels. Direct mounting on the burner is also permitted. The unit housing, made from impact-proof and heat-resistant plastic, contains the power section, the self-checking electronic flame signal amplifier with its flame relay, and a flame indication lamp. The plug and socket arrangement is designed such that erroneous plugging in of another type of unit into the baseplate is not possible. The spacious baseplate with four auxiliary terminals and four earth looping terminals facilitates the electrical installation. UV detector QRA50M for mounting onto a viewing tube (frontal light entry) The injection die-cast alloy detector head is sealed with a quartz-glass lens. In addition to the plug-in UV cell, the detector head contains a rotating shutter which - for the purpose of continuous testing of the UV cells striking and extinction voltage performance - interrupts the UV radiation at the rate of three times per second. The shutter is driven by a synchronous motor which has proved suitable for continuous operation over many years. The fixing of the detector onto the viewing tube is achieved by means of a mounting coupling with a 1 in. internal thread. A 3/8 in. tapping on the side of the coupling enables a cooling air conduit to be connected, provided dry, dust- and oil-free compressed air is available for this purpose. UV detector QRA51M for burner mounting (lateral light entry) The detector head, painted light grey/dark grey, is dust- and drip-proof. It has a flangedon robust, aluminium tube with a radiation entry window for lateral viewing. In this tube rotates a cylindrical, slotted shutter which interrupts the incidence of UV radiation to the UV cell, which is mounted directly behind the radiation entry window, at a rate of about three times per second (continuous testing of the striking and quenching performance of the cell). The outer tube can be rotated through 180 by loosening two locking screws. A special clamping flange is supplied with the detector to ensure its vibration- and turningproof fixing to the burner. 2/11 CC1N7783E March 11, 1997 Landis & Staefa

Mode of operation The flame is supervised by the UV cell, which is permanently under voltage. The UV cell strikes and effects a current flow to the flame signal amplifier input when subjected to radiation from the 190...240 nm range of the flame spectrum. The flame signal is transmitted via the contacts of the flame relay at the amplifier output to the control circuit of the burner such that with flame failure, the fuel valves are immediately closed and all other necessary control commands are automatically initiated (burner lockout, lockout alarm signal, etc.). With a self-checking flame supervision system, it must be ensured that only the detector current emitted in the presence of a flame is actually amplified and used as the «flame on» supervision signal. All other currents not generated through flame radiation, e.g. current emission from a self-striking UV cell (caused by ageing) or from any other detector circuit defect which simulates a flame, must be differentiated against and not treated as a flame signal. Thus, the flame safeguard must be able to differentiate clearly between a true flame signal and an erroneous flame simulation signal. For this purpose, the incident radiation at the UV cell is interrupted three times per second by a continuously rotating shutter. The shutter is so designed that is allows «light» and «dark» phases of practically equal length. Thus, the amplifier input does not receive a constant signal. The input signal is «cyclic». This ensures that the flame relay is energized only if the following prerequisites are fulfilled: - Flame is present - The intensity of UV radiation at the viewing point of the detector must be such that the UV cell will strike regularly from the beginning to the end of the «light» phase - The rotating shutter rotates at the determined speed so that the light and dark phases are given at the uniform rate of three times per second - The electric and electronic components of the flame signal amplifier function correctly Warnings In the geographical areas where DIN standards are in use, the installation must be in compliance with VDE requirement, particularly with the standards DIN/VDE 0100 and 0722! The electrical wiring must comply with national and local standards! Check wiring carefully before putting the unit into operation! Ensure protection against electric shock hazard on the unit and at all electrical connections by appropriate mounting! The LFE50 is a safety device! The loosening of the sealing screws as well as any changes to the factory-settings must therefore be carried out by authorized staff only! Check all safety functions when putting the unit into operation or after having replaced any fuses! The LFE50 must be completely isolated from the mains before performing any work on it! Condensation and ingress of humidity must be avoided! Ignition cable must always be laid separately, observing the greatest possible distance to other cables! Electromagnetic emissions must be checked from an application point of view! To protect the burner control from electric overload, both ignition and ionization electrode must be located such that arcing over of the ignition spark to the ionization electrode cannot occur! Observe the notes for laying the detector cables (refer to «Technical data»)! Landis & Staefa CC1N7783E March 11, 1997 3/11

Technical data Flame safeguard LFE50 Mains voltage AC 220 V -15 %...240 V +10 % External fuse 10 A max., slow AC 100 V -15 %...110 V +15 % Unit fuse 250 ma, slow; 5 x 20 mm Radio interference protection to VDE no radio interference Frequency 50...60 Hz ±6 % Operating voltage for Degree of protection IP40 - UV cell 250 V Mounting position optional - Rotating shutter motor 63 V Perm. contact loading 2 A max. Weight approx. 1.5 kg Power consumption approx. 13 VA Environmental conditions CE conformance - Transport IEC721-3-2 According to the directives of the European Community Climatic conditions class 2K2 Electromagnetic compatibility EMC Temperature -50...+60 C 89/336 EEC include. 92/31 EEC Humidity < 95 % r.h. Gas appliance directive 90/396 EEC Mechanical conditions class 2M2 Emissions EN 50081-1 - Operation IEC721-3-3 Immunity EN 50082-2 Climatic conditions class 3K5 Temperature -20...+60 C Humidity < 95 % r.h. Condensation, formation of ice and ingress of water are not permitted UV detector Degree of protection QRA50M: IP54 Perm. cable lengths QRA51M: IP40 - Using 5-core cable (for terminals 9, 10, 17, 18 and earth) 30 m max. Mounting position optional - Using 2-core cable Perm. ambient temperature -20...+50 C (for terminals 9 and 10 and 3-core cable Perm. storage temperature -55...+50 C for terminals 17, 18 and earth) 200 m max. Perm. pressure on the lens of the QRA50 500 mbar max. Weight of QRA50 / QRA51 approx. 0.75 kg Ordering Flame safeguard With baseplate AC 220 V...240 V LFE50 AC 100 V...110 V LFE50 - AC 110 V UV detector for mounting onto a viewing tube, complete with flange UV detector for burner mounting (lateral viewing), complete with clamping flange QRA50M¹) QRA51M¹) Spare UV cell - For QRA50M 4 502 4268 0 - For QRA51M 4 502 4065 7 Replacement fuse 250 ma, slow, 5 x 20 mm 4 519 1033 0 ¹) For all voltage variants 4/11 CC1N7783E March 11, 1997 Landis & Staefa

Prerequisites for reliable burner operation Checking of UV radiation intensity at the detector s viewing point by measuring the detector current Minimum detector current required with nominal voltage AC 220...240 V 70 µa Maximum possible detector current with nominal voltage AC 220...240 V 140 µa Internal resistance of measuring instrument «M» 5000 Ω max. Capacitance of capacitor «C» (to facilitate reading) 470 µf min./dc 25 V Arrangement of units for measurement This check of the UV radiation intensity, which also tests the striking performance of the UV cell, should be made not only during commissioning of the burner, but each time the UV cell has been changed. This check is also recommended in the event of modifications being made which affect the original operating conditions of the burner, for example changes to the burner head, introduction of combustion additives into the fuel (possible impact on filter), or any other changes carried out, which may lead to a reduction of incidence of radiation at the UV cell. Correct positioning of detector The ignition spark is a source of intensive UV radiation. If the burner has a long preignition time, the viewing tube of the detector should therefore be sited at the flame in such a way that the ignition spark lies outside the angle of incidence of UV radiation to the detector. If this is not observed, the burner control will lock out during the start-up sequence. In the case of burner installations for which ignition spark proving is specified, the viewing tube must be so sited that the UV radiation of both the ignition sparks and the flame are detected equally well. The discharge light of a UV cell may also be a source of UV radiation. In the case of burner supervision with two UV detectors, it must be ensured - through appropriate location of the cells - that they do not influence each other. Warning Powerful electron rays or X-rays may lead to faulty flame signals. This also applies to UV proportions in the light of halogen or gas discharge lamps. The QRA5... must be installed and adjusted such that only the flame to be supervised will be detected. Landis & Staefa CC1N7783E March 11, 1997 5/11

Protection of detector head against overtemperatures The service life of a UV cell is reduced with increasing ambient temperature. Under continuous operating conditions, the ambient temperature should not exceed 50 C. If the detector is mounted on a tube viewing into the combustion chamber, this temperature limit is often exceeded as a result of heat conduction. In this case, the UV cell s ambient temperature must be lowered by means of blowing cool air through the viewing tube into the combustion chamber (sketch A). Lateral air entry at an angle of 90 to the viewing tube (sketch B) is permissible only if the cooling air is dry and absolutely dust- and oil-free. Otherwise, the sealing disk of the detector head will become soiled, thereby reducing the incidence of radiation at the UV cell - or even block it completely. Basic circuit diagram Legend AL Alarm LEC1... Control unit BV... Fuel valve LFE10 Flame safeguard (for intermittent operation) C Capacitor LP Air pressure monitor DB Rotating shutter M... Fan FE Detector electrode QRA50/51 UV detector FR Flame relay S Fuse GP Gas pressure monitor (or similar) SM Synchronous motor with reduction gearing H Mains isolator UR UV sensitive cell (UV detector) HR... Auxiliary relay V Flame signal amplifier L1, L3 Flame indication lamp (built-in) W Limit thermostat or pressure monitor L4, L5 Flame indication lamp (remote) Z Ignition transformer 6/11 CC1N7783E March 11, 1997 Landis & Staefa

Connection examples Flame supervision of an expanding flame burner with DETACTOGYR 1. Automatic operation A control unit type LEC1... is required to control the burner. Switching of the burner is achieved automatically by means of the heat generation plant s control thermostat or pressurestat. 2. Semi-automatic operation This form of operation differs from automatic operation only in that the burner is switched on manually (pushbutton «I») - providing signal lamp «L5» indicates that the control unit LEC1... is «ready to start». The burner can be shut down either manually (pushbutton «0») or automatically through a limiter in the control loop between terminals 8 and 9. Connection examples for burner operation are given in data sheet 7761 for the control unit LEC1... Landis & Staefa CC1N7783E March 11, 1997 7/11

Supervision of an expanding flame burner with two selfchecking flame supervision systems DETACTOGYR in an active redundancy circuit This circuit is used when burner operation must be maintained even in the event of a fault in the flame supervision circuit. With failure of a flame safeguard or a UV cell - signalled by a horn or similar - self-checking supervision is maintained by the second system. This allows the fault to be corrected without having to shut down the burner. 8/11 CC1N7783E March 11, 1997 Landis & Staefa

Flame supervision of the main flame (A) of an interruptedpilot burner with DETACTOGYR Supervision of the pilot burner (B) using an ionization detector electrode «FE» and a flame safeguard LFE10 (up to completion of the 2nd safety time). Burner controlled with control unit LEC1..., as shown in data sheet 7761. This data sheet also contains information on the LFE10; further details are given in data sheet 7781. Landis & Staefa CC1N7783E March 11, 1997 9/11

Flame supervision of a manually operated single-stage burner with DETACTOGYR * If start-up shall be accomplished with ignition spark supervision, the UV detector must be installed such that it can detect the ignition spark and the flame equally well. In that case, the current path to the fuel valve must be connected to terminal 3 or 12 to make certain fuel will be released only after the flame safeguard has received an ignition spark signal (indicated by signal lamps L3 and L4). After the lamps have been lit, pushbutton «I» must be kept depressed until the burner has ignited. If the time of flame establishment shall be indicated also, flame safeguard LFE10 can be used (refer to data sheet 7781). Actuation of pushbutton «I» switches the ignition transformer on. At the same time, relay «d» is energized and releases the fuel supply. The length of time during which pushbutton «I» may maintain its «start signal» should be limited by means of a time relay. When the burner ignites, flame relay «FR» is energized, so that relay «d» is held in the energized position via current path 3-7 of the flame safeguard. The ignition transformer is switched off when pushbutton «I» is released. This completes the manual start-up sequence. The burner is switched off manually by pressing pushbutton «0», or automatically by means of a monitor in the phase connection. In the event of a flame failure or any other faults in the flame supervision circuit, the fuel supply is immediately interrupted. If such a fault occurs during a burner off period, neither ignition nor fuel release can be achieved. Warning The drop out delay time of relay «d» may not exceed 50 ms! 10/11 CC1N7783E March 11, 1997 Landis & Staefa

Dimensions Dimensions in mm Flame safeguard LFE50 (Baseplate 4 104 9023 0 is supplied with every LFE50; no separate order required) 32 ca. 75 53,5 ~77 R1" R3/8" 29 50 19 46 115 o8 o4,5 UV o32 15,5 100 132 23 23 119 75 4,5 12 21 60 ca. 107 7783m04/1196 ~40 107 UV detector QRA50... (with mounting coupling) for mounting onto a viewing tube UV detector QRA51... for burner mounting Landis & Staefa Produktion (Deutschland) GmbH Landis & Staefa CC1N7783E March 11, 1997 11/11