Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

Similar documents
Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

Preamplifier Power Supply PPS-02 user's guide

IR detection module VPAC-1000F user's guide

IR detectors user's guide

Series: MBC1-TC Mini Benchtop Temperature Controller

Compact Equipment Warranty Policy

ion Genesis Pump Controller

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

OPERATION AND INSTALLATION MANUAL

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Installation and Operations Manual

Installation Manual. THM-0100 Setpoint Thermostat Version THM HBX Control Systems Inc.

EQUIPMENT Operation Manual

VX SERIES Wireless Thermostat with Occupancy Sensor

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

Duct Mount. Installation Instructions

Horizontal Bottle Cooler Installation and Operation Manual

Operation and Maintenance Manual for the SODRTEK ST 400 Radiant Pre-Heating System P/N

External Wireless Sounder

Notes: 1 Square = 1 Foot

1228s Multidrop INSTRUCTIONS. Installation and Operation of the AMC-1228s Electrochemical Sensor Module For Use With Multidrop AMC Monitors

CD6102 / CD6102 OC / CD6102-2

Reacti-Therm I and III Heating Modules

WATCHMAN Model LBW-WATCHMAN Ammonia Leak Detector

Light Construction Equipment Consumer Warranty Policy

Quick-Start Operating Guide Document No Acrylic Vacuum Chambers Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

(HSTAT Series) Instruction Manual

Air Pump Up to 800 gallons

External Wireless Sounder


HotPoly Tote Tank / IBC Heaters (TTH Series)

Owner s Manual. PIR-1 IR Learner

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL

INSTALLATION AND OPERATING INSTRUCTIONS FOR THE VEHICLE-MOUNTED RADIATION DETECTION SYSTEM

HIGH VOLTAGE A.C. PROXIMITY DETECTOR HI-PROX

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Laser Distance Sensor Type M Analog-Output

AMC-CD2. Human Occupancy Detector INSTRUCTION MANUAL. Please read these instructions completely and carefully before starting.

GETZ MANUFACTURING PART # CYLINDER DRYER

MariGlo LED. Inspiring Excellence in Fish Keeping! 45 / 60 / 90 / 120.

CT2 Retro Box Installation Instruction Manual

Thermometer model 02059

aquamanta the experts in aquatic technology CH 025/050/100/ 150/200/300 NEW PHOTO Instruction Manual

EVD-1 Installation, Operation, and Instruction Manual

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL

esense CO2 Transmitter and Alarm

XPIN -XT X-ray Detector Operation Manual

Turbo Air Speed up the Pace of Innovation TBB-4SB CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT

AMC-RAM-4. Refrigerant Alarm Module USER MANUAL. Please read the installation and operating instructions completely and carefully before starting.

Remote Vehicle Control System

Introduction... 1 System Overview... 1 System Diagram... 2

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL. Manual v1.0

10810 W. LITTLE YORK RD., STE. 130 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL

This instruction manual explains the use of three models listed on the left.

Operation Manual Vortex mixer unitexer 1

PM100/PM100E PLANTER MONITOR. Operator s Manual

Environmental Monitoring SmartSlot Card

View the expanded manual: GEN5

3800 North Mill Road Vineland, NJ USA Tel: Fax: Web: Rev. A

6502B RF Distribution

EQUIPMENT Operation Manual

MAN AUTO IMPORTANT INSTRUCTIONS PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE

OPERATING INSTRUCTIONS FOR: MODEL: TGO-80W, 150W, 240W GLASSWARE DRYING OVEN

Model NT20e Installation Guide

20 High velocity Air

Introduction... 1 System Overview... 1 System Diagram... 2

CWR265SZ 26 Bottle Built-in Wine Cooler Owner s Manual

PIR Sensor. User s Guide

! "! # Please read these installation and operating instructions completely and carefully before starting.

A2Z Ozone, Inc. PRODUCT MANUAL

Pressurized Filter Up to 1250 gallons

OPERATION & INSTALLATION MANUAL

Thermometer with Probe model 00891A

Installation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc.

Rev. E 2013 Pentair Technical Products P/N Distributed by: McLean Parts

USER S OPERATING AND INSTRUCTION MANUAL

ECA-DIN. Users Manual. Current and Voltage Alarms. March 2018

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

ES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor

Installation & Operation Manual

Room Monitor SAVE THIS MANUAL FOR FUTURE REFERENCE.

EQUIPMENT Operation Manual

CHARGED PLATE DETECTORS

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

NIR O P E R A T I N G I N S T R U C T I O N S RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

I.D.L. Heaters Thermal Products Ltd. Roll n Warm Installation Manual

COMMERCIAL REFRIGERATOR INSTRUCTION MANUAL

1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR

XC Portable Air Conditioning

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

Industrial Vacuums, Inc

Instruction Manual. AcuRite Atlas. Indoor Display model 06061

Hades 2. Digital Recycle and Lighting Timer with High Temp Shut-Off Instruction Manual. Notes: 1 Square = Foot/Feet

Installation Guide

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL

Glass Door Merchandiser Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

EOS. Instruction Manual. 120V High Amperage Digital Humidity Controller. Part #

TESTSAFE. minipat APPLIANCE TESTER USER MANUAL

Transcription:

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide 1

Table of Contents 1. Warranty... 3 2. MTCC-01-xxx overview... 4 2.1. MTCC-01-xxx specification... 4 2.2. TE cooled detector temperature stabilization general information...5 2.3. MTCC-01-xxx operation... 6 2.4. Connectors... 7 2.5. Sample kit wiring... 8 2.6. MTCC-01-xxx physical dimensions [mm]...8 3. Getting started regards complete IR detection kit...9 3.1. Unpacking... 9 3.2. Installation & connections... 9 3.3. Switching on procedure... 9 4. MTCC-01-xxx other related information...10 4.1. CE Statement of conformity...10 4.2. Electromagnetic interference... 10 4.3. Operating temperature... 10 4.4. Storage information... 10 5. Safety instructions... 11 6. Troubleshooting... 12 2

1. Warranty VIGO System S.A. hereby represents and warrants all Products manufactured by VIGO and sold hereunder to be free from defects in workmanship or material during a period of twelve (12) months from the date of delivery save for products for which a separate warranty is given. If any Product proves however to be defective in workmanship or material within the period herein provided VIGO System undertakes to the exclusion of any other remedy to repair or at its own option replace the defective Product or part thereof free of charge and otherwise on the same conditions as for the original Product or part without extension to original warranty time. Defective parts replaced in accordance with this clause shall be placed at the disposal of VIGO. VIGO also warrants the quality of all repair and service works performed by its employees to products sold by it. In case the repair or service works should appear inadequate or faulty and should this cause malfunction or nonfunctioning of the product to which the service was performed VIGO shall at its free option either repair or have repaired or replace the product in question. The working hours used by employees of VIGO for such repair or replacement shall be free of charge to the client. This service warranty shall be valid for a period of six (6) months from the date the service measures were completed. This warranty is however subject to following conditions: 1. A substantiated written claim as to any alleged defects shall have been received by VIGO System within thirty (30) days after the defect or fault became known or occurred, and 2. The allegedly defective Product or part shall, should VIGO so require, be sent to the works of VIGO or to such other place as VIGO may indicate in writing, freight and insurance prepaid, properly packed and labeled. This warranty does not however apply when the defect has been caused through 1. 2. 3. 4. 5. 6. 7. 8. 9. normal wear and tear or accident; misuse or other unsuitable or unauthorized use of the Product or negligence or error in storing, maintaining or in handling the Product or any equipment thereof; wrong installation, assembly or failure to service the Product or otherwise follow VIGO's service instructions including any repairs or installation or assembly or service made by unauthorized personnel not approved by VIGO or replacements with parts not manufactured or supplied by VIGO; modifications or changes of the Product as well as any adding to it without VIGO's prior authorization; burned active element by irradiation above damage thresholds electrostatic discharges improper detector bias improper TE cooler bias (TE cooler damage or active element overheating). other factors dependent on the Customer or a third party. Notwithstanding the aforesaid VIGO System liability under this clause shall not apply to any defects arising out of materials, designs or instructions provided by the Customer. This warranty is expressly in lieu of and excludes all other conditions, warranties and liabilities, expressed or implied, whether under law, statute or otherwise, including without limitation any implied warranties of merchantability or fitness for a particular purpose and all other obligations and liabilities of VIGO or its representatives with respect to any defect or deficiency applicable to or resulting directly or indirectly from the Products supplied hereunder, which obligations and liabilities are hereby expressly canceled and waived. VIGO's liability shall under no circumstances exceed the invoice price of any Product for which a warranty claim is made, nor shall VIGO in any circumstances be liable for lost profits or other consequential loss whether direct or indirect or for special damage. RMA Request Instructions: No Product may be returned without first contacting VIGO for a Return Material Authorization ('RMA') number. Please obtain a RMA number at claim@vigo.com.pl before returning any item. When requesting a RMA number, please state your order number, the product you wish to return and the reason for return. We will only accept returns which have an RMA number. Authorized returns are to be shipped according to received instruction from VIGO in appropriate shipping box. An unauthorized return, i.e. one for which an RMA number has not been issued and authorized returns however, shipped with incorrect customs documents - will not be accepted. Please print the RMA number clearly on the return label to avoid any delay in processing. Please send package to: VIGO System S.A. 129/133 Poznanska St., PL 05-850 Ozarow Mazowiecki Poland 3

2. MTCC-01-xxx overview The MTCC-01-xxx (Miniature Thermoelectric Cooler Controller) is the module designed for supplying the thermoelectric cooler (being a part of the cooled IR detector) and providing the temperature stabilization process. The MTCC-01-xxx is suited to work with 2- and 3- stage cooled detector (2TE, 3TE). Due to the compact size, MTCC-01-xxx is especially convenient to use in OEM applications. Features Compact size Low cost Factory configured (user should NOT change these settings) High stability and precision Adjustable temperature Low power consumption 2.1. MTCC-01-xxx specification Parameter Unit Typical value Conditions, remarks 1) Temperature stability K ± 0.01 Settling time of the set detector temperature s 60 90 2-stage TEC, Tdet=230K 3-stage TEC, Tdet=210K Power supply voltage VDD V 2.6 to 5.5 4.0 to 5.5 for 2-stage TEC for 3-stage TEC Maximum TEC output current ITEC A 1.10 0.43 for 2-stage TEC for 3-stage TEC Maximum TEC output voltage Vtec V Dimensions 3.6 mm 70 x 45 x 19 Weight g 1) O Electrical characteristics @ TAMB = 20 C, VDD = 5 V width x depth x height 35 4

2.2. TE cooled detector temperature stabilization general information Every cooled detector, besides containing IR sensitive structure, is equipped with: TEC (ThermoElectric Cooler), Thermistor. Depending on the requirements, like responsivity, noise level, and therefore the final temperature, detectors fabricated by VIGO contain 2-, 3- or 4-staged TE cooler. The lowest achievable temperature depends also on ambient temperature and the heat dissipated by the detector due to the detector biasing. Considering all the factors and preparing measurements under conditions comparable with those in final application, detectors are described and the final temperature is defined. The thermistor being inside the detector package gives the feedback about the IR sensor temperature and allows the controller to perform the temperature control process. The thermistor is a component common for every type of the IR sensors, which makes the temperature measurement simple and repetitive for each detector. Having the detector parameters measured, the MTCC-01-xxx controller parameters (max current, depending on the cooler) and final temperature are set, and the system is ready to work. The MTCC-01-xxx module contains low noise and precise analog path, PID controller block, and the power stage for Peltier element driving. It also has diode indicating the actual state of the controller (getting the temperature down / ready to work). Temperature controller basing on the PID algorithm allows the system to quickly achieve the final temperature, keeping it long term stable with small fluctuations and can also adapt to varying environment conditions. The MTCC-01-xxx is a linear controller, so it doesn't introduce disturbances to the IR detection system and does not affect its performance. The MTCC-01-xxx is configured at the factory to achieve stable temperature of the detector at any ambient temperature up to 30 C (unless other value agreed at time of order). 5

2.3. MTCC-01-xxx operation Selecting the MTCC-01-xxx parameters MTCC-01-xxx controller was configured at factory to work with defined IR detection module. Do not change any setting, do not change controllers between modules. They are not equivalent. 6

LED indicators MTCC-01-xxx controller has two LED diodes indicating the state of the module. RED diode (marked as POWER) is lighted if the controller supply (VSUP) is properly connected. GREEN diode (marked as LOCK) is lighted if the detector temperature achieves the set value. After turning on the power supply the GREEN LED should be off for a maximum 300 seconds depending on the detector type. 2.4. Connectors The picture below shows the pin configuration of the module. Supply connector Preamplifier connector AMP 1x6 AMP 2x4 Pin Symbol Function Pin Symbol Function 1 +VDD TEC controller power supply 1 -VSUP Power supply output (-) 2 TGND TEC controller power supply 2 TH2 Thermistor input 3 +VSUP Power supply input (+) 3 Vfan / N.C. Fan supply / open 4 GND Power ground 4 -TEC TEC supply output (-) 5 Vfan / N.C. Fan supply / open 5 GND Power ground 6 -VSUP Power supply input ( ) 6 TH1 Thermistor input 7 +VSUP Power supply output (+) 8 +TEC TEC supply output (-) 7

2.5. Sample kit wiring 1 3 4 2 The sample IR detection kit consists of: 1) MTCC-01-xxx controller, 2) IR detection module (in the picture: SIPXC) 3) AMP 2x4 AMP 2x4 cable 4) AMP 1x6 power cable 2.6. MTCC-01-xxx physical dimensions [mm] 8

3. Getting started regards complete IR detection kit 3.1. Unpacking Before unpacking, verify if there are no visible damages of the package. Report them to the manufacturer or the distributor. 3.2. Installation & connections Mount the IR module in the measurement setup, Connect all elements with cables provided in the package, Make sure that all the elements are properly connected. The TEC controller is matched in the factory with the detector delivered in the IR detector set. Do not swap controllers between IR sets. 3.3. Switching on procedure Do not switch on the IR module power supply until ALL elements of the IR detection kit are correctly connected with the proper cables, Do not switch on the IR detector set power supply until you have confirmed that the detector set is adequately heat sinked (SIPxC and MIPxC series only). Switch on the thermoelectric cooler controller and wait until detector operating temperature is reached and stabilized. Ready state will be indicated by the LOCK green LED light, Before starting the measurements make sure the load resistance is valid. IR detector module output should be terminated by 50Ω or 1MΩ resistance depending on the bandwidth and is given in the test data provided on the module, Do not manipulate any connectors on the active IR kit this may introduce additional noises to the system or can cause severe damages due to electrostatic discharges. 9

4. MTCC-01-xxx other related information 4.1. CE Statement of conformity VIGO System declares that IR detection kit is fully compliant with: EU Low Voltage Directives: 73/23/EEC, 93/68/EEC EU Electromagnetic Compatibility Directives: 89/336/EEC, 91/263/EEC, 92/31/EEC, 93/68/EEC 4.2. Electromagnetic interference To avoid the electromagnetic interferences (EMI), please do not put any electromagnetic source close to the IR module. That may cause interference to the input of the preamplifier and disturb the useful signal in the IR track 4.3. Operating temperature Detector parameters are guaranteed for the environment temperature not exceeding 35 OC. 4.4. Storage information To ensure reliable operation and long lifetime of detector, the following conditions should be fulfilled: Storage temperature: -10ºC + 50ºC and 10% to 90% humidity, Avoid exposing to direct sunlight and strong UV/VIS light as this may result in degradation of a detector performance, Avoid electrostatic discharges (ESD). 10

5. Safety instructions To ensure safe and failure-free operation of the MTCC-01-xxx controller, comply with the following precautions: Do not swap TEC controllers between IR sets match serial number. Before connecting the power supply to the mains, make sure if it is compatible with the mains voltage and frequency. Do not use the controller if the temperature and the air humidity extends the values valid for the MTCC-01-xxx controller. Use the cables supplied to connect elements of the kit, dedicated for specified device only. Never cut or shorten any cable, it may cause damage to your device. Use the cables delivered by VIGO. In case of OEM systems, make sure the the cables match the specification of the controller. Turn off the power supply before plugging / unplugging cables. Avoid static discharges. MTCC-01-xxx controller is an OEM type, so it is not equipped with a case. Provide the proper shielding and avoid touching the module while operating. MTCC-01-xxx module doesn't require forced air cooling, but keep the radiator uncovered and allow the air to flowover the module. Important Note! If you are setting up own system with your own power supply, please make sure, the voltage/current matches the values of the TEC and the IR detector. 11

6. Troubleshooting Typical reasons of malfunction the controller and the possible solutions are collected in the following table. Symptom SUPPLY diode is not shining LOCK diode is never turned on, or turns of after some time LOCK diode is blinking Possible reason Typical solution Controller is not connected to the supply Connect the controller and the power supply together Power supply is not connected to the mains Connect the power supply to the mains Controller or power supply is broken Contact with the distributor or the manufacturer The controller is not connected with the IR detector Properly connect the controller and the detector TEC efficiency is too small Increase the final detector temperature by reconfiguring switches or using potentiometer Environment temperature is too high Keep the environment temperature within the limits. Controller or IR detector is broken Contact with the distributor or the manufacturer IR radiation flux is too strong Reduce the IR radiation level IR detector position is unstable, or it is exposed to the vibrations Properly mount the IR detector and keep it mechanically stable Controller or IR detector is broken Contact with the distributor or the manufacturer 12