United States Price List

Similar documents
United States Price List

Kingsman Catalogue. Wolseley Fireplace Catalogue. Proud Sponsor of: All prices are MFG list prices

United States Price List April 1, 2018

Hearth Products For the Specialty Hearth Dealer

ZERO CLEARANCE DIRECT VENT GAS FIREPLACE

Zero clearance direct vent gas fireplace

ZERO CLEARANCE DIRECT VENT GAS FIREPLACE

BENTLEY ZERO CLEARANCE DIRECT VENT GAS FIREPLACE

SOLACE. Zero Clearance Direct Vent Gas Fireplace

Zero Clearance Direct Vent Gas Fireplace

f i r e - p a r t s. c o m

Multi-Sided Direct Vent Decorative Gas Fireplace

Free Standing Direct Vent Gas Stove

f i r e - p a r t s. c o m

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions Model Number VRB46 Zero Clearance Vented Gas Fireplace Heater

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

Installation Instructions Model Number VRB46 Zero Clearance Vented Gas Fireplace Heater

Installation Instructions

Installation Instructions

AUSTIN % Natural Gas efficiency 38,000 BTU Top 4" / 7" Venting

AUSTIN % Natural Gas efficiency 38,000 BTU Top 4" / 7" Venting

Enviro. Designed to heat. Built to last. Designed to heat. Built to Last. For over 25 years, unsurpassed quality and craftsmanship

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

INSTALLATION INSTRUCTIONS MODEL NUMBER PVH58 HORIZONTAL POWER VENT TERMINATION

Installation Instructions

Multi-Sided Direct Vent Decorative Gas Fireplace

ENCLAVE ZERO CLEARANCE DIRECT VENT BAY PENINSULA GAS FIREPLACE

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

Model 31 and 33 DVI Fi rest y l es for Life

Installation Instructions

The Stanford 55L. Direct Vent Linear. Model Number Description MSRP

Installation Instructions

Manufactured by Sherwood Industries Ltd Victoria, BC, Canada enviro.com Printed in Canada, April 2017

For Propane Horizontal installations the venting must be a minimum of one foot vertical off the flue before going horizontal.

Installation Instructions Model Number ZRB46 Zero Clearance Vented Gas Fireplace Heater

designed to heat. built to last. GAS FIREPLACES

Installation Instructions Model Number FDV451 & MQFDV453 Free Standing Direct Vent Gas Stove

Real Fyre Direct Vent Inserts 2017 Product Brochure RH Peterson Co.

Installation Instructions Model Number ZDV3318, ZDV3622, ZDVRB3622 Zero Clearance Direct Vent Fireplace

BAYPORT 41 & BAYPORT 36

Model 31 and 33 DVI Gas Fireplace Inserts

BAYPORT 41 & BAYPORT 36

BAYPORT 41 & BAYPORT 36

BAYPORT 41 & BAYPORT 36

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems

bayport 41 & bayport 36

bayport 41 & bayport 36

H35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw)

H35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw)

Gas Inserts FEATURING

Gas Stoves. C34-10 Direct Vent Gas Stove. Side wall E F. Back wall F E. Model C34-NG10 C34-LP10

FYRESTARTER IPI. Gas Inserts. Direct Vent Systems WHAT A FIRE IS MEANT TO BE

Infinite Series. Installation Instructions

Installation Instructions Model Number FDV350 Free Standing Direct Vent Gas Stove (Field Convertible to Vented Stove)

Infinite Series Installation Instructions

GAS LOGS. Traditional. Fireplace Design Collection VENT-FREE

31 and 33 DVI Gas Fireplace Inserts

carlton 46 & carlton 39

Gas Fireplaces FEATURING

Tahoe Direct-Vent Fireplaces

Madison Series Direct-Vent Fireplaces

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

MONTEBELLO DLX. Traditional. Fireplace Design Collection DIRECT VENT GAS FIREPLACES

vent-free fireplaces Surround Yourself With Comfort

P P Gas Fireplace. P See Thru

GAS LOGS VENT-FREE. Our name is our promise. SUPERIOR GAS LOGS elevate the traditional log and fire presentation to a much higher level.

Gas Inserts & Freestanding FEATURING

CARLTON 46 & CARLTON 39

DoctorFlue.com. Traditional Series D i r e c t V e n t MODELS WINDOM SP Windom Specifications Specifications...6

Installation Instructions

Gas Fireplaces FEATURING

designed to heat. built to last. GAS FIREPLACE INSERTS

Direct Vent Fireplace Systems

GAS. F I R E P L A C E s

The Ravelle direct-vent gas fireplaces balance elegant design, premium-quality construction, and two heating capacities for unmatched flexibility.

RAVELLE DIRECT-VENT GAS FIREPLACES

OUTDOOR FIREPLACE MANUAL

Venting. Vent Material. Approved Venting Accessories Simpson Dura-Vent DV unless otherwise specified. Wall Thickness

DV TruFlame Catalyst Fireplaces, Canvas Portrait Fireplaces

Direct Vent Gas Inserts & Freestanding FEATURING

Installation Instructions

RAPTURE. Traditional. Fireplace Design Collection B-VENT GAS FIREPLACES

Direct Vent Luxury Fireplace Systems

the vail series vent-free gas fireplaces Surround Yourself With Comfort

INSTALLATION INSTRUCTIONS

SLAYTON 60, SLAYTON 42S & SLAYTON 36

CARLTON 46 & CARLTON 39

symmetry series louverless direct-vent Gas Fireplaces

Direct Vent Systems WHAT A FIRE IS MEANT TO BE

Stoves & Inserts. Gas. continentalfireplaces.com

Direct Vent Fireplace Systems

Direct Vent Gas Fireplaces WELCOME GREAT STYLE INTO YOUR HOME

Outdoor Bi-Fold Doors w/frame and Hood - Brushed Stainless. Stainless Steel Outdoor Weather Cover (cannot be used with doors in place)

RAPTURE. Traditional. Fireplace Design Collection B-VENT GAS FIREPLACES

CAPRI. INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

TIMELESS NORWEGIAN CRAFT GAS PRODUCTS

delano 36S & Nicollet 195S

Transcription:

United States Price List Effective October 1, 2018 (Revised 08/01/2018) Phone 204 632 1962 Fax 204 632 1960

TABLE OF CONTENTS Model Number Description Page Number FDV350 Free Standing Direct Vent Stove 3 FDV451 Free Standing Direct Vent Stove 4 Venting Accessories - Direct Vent Stoves 6 ZDV3318 Zero Clearance Direct Vent Fireplace 7 ZCV3622 Zero Clearance Direct Vent Clean View 36" 8 ZCVRB3622 Zero Clearance Direct Vent Clean View - Linear 9 HBZDV3624 Zero Clearance Direct Vent Fireplace 10 HBZDV3628 Zero Clearance Direct Vent Fireplace 11 HBZDV4224 Zero Clearance Direct Vent Fireplace 12 HBZDV4228 Zero Clearance Direct Vent Fireplace 13 HBZDV4736 Zero Clearance Direct Vent Fireplace 14 VRB46 Zero Clearance Direct Vent Clean View - Linear 15 ZCV39 Zero Clearance Direct Vent Clean View 39 Decorative 16 ZCV39H Zero Clearance Direct Vent Clean View 39 Heater 18 ZCV42 Zero Clearance Direct Vent Clean View 42 Decorative 20 ZCV42H Zero Clearance Direct Vent Clean View 42 Heater 22 MDV31 Multi-Sided Direct Vent Fireplace 24 Venting Accessories - 4/7" Direct Vent Fireplaces 26 Power Venting - 5/7" Direct Vent Fireplaces 27 MCVP42 Peninsula Clean View Direct Vent Fireplace - Decorative 28 MCVP42H Peninsula Clean View Direct Vent Fireplace - Heater 30 MCVST42 See Through Clean View Direct Vent Fireplace - Decorative 32 MCVST42H See Through Clean View Direct Vent Fireplace - Heater 34 Venting Accessories - 5/8" Direct Vent Fireplaces 36 Power Venting - 5/8" Direct Vent Fireplaces 37 ZV3600 Zero Clearance B-Vented Fireplace 38 IDV26 Direct Vent Fireplace Insert 40 IDV33 Direct Vent Fireplace Insert 42 IDV43 Direct Vent Fireplace Insert 45 VFI25 Vented Fireplace Insert 48 FP2085/2785 Outdoor Fire Pits & Fire Bowl 49 OFP42 Outdoor Gas Fireplace 50 VB18/24 Gas Log Sets - Vented 51 GL24/40 Gas Log Sets - Vented/Vent Free 52 ZVF24 Vent Free - Zero Clearance Firebox 53 ZVF33 Vent Free - Zero Clearance Firebox 54 MVF40 Vent Free - Multi-Sided Firebox 55 ZVFCV39 Vent Free - Clean View Circulating Universal Fire Box 56 ZVFCV42 Vent Free - Clean View Circulating Universal Fire Box 57 ZVFZCV47 Vent Free - Clean View Circulating Universal Fire Box 58 FVF350 Vent Free- Free Standing Stove 59

Page 3 FDV350 FREE STANDING DIRECT VENT GAS STOVES: Listed for USA/Canada as a Vented Gas Fireplace Heater, Dual Burner, Bay Viewing Area, Black Louver, Adjustable SIT Valve. 4/7 Flue, Certified for use in Mobile Home, Bedroom, and Bed sitting Room, Safety Screen Barrier, Flat Black, 37,000 BTU NG, 35,000 BTU LP FDV350N Free Standing Stove Millivolt Natural Gas $1,835 FDV350LP Free Standing Stove Millivolt Propane 1,900 FDV350NE2 Free Standing Stove Proflame 2 IPI Remote Thermostat Mod Fan NG 2,835 FDV350LPE2 Free Standing Stove Proflame 2 IPI Remote Thermostat Mod Fan LP 2,900 350DV CKLP Conversion Kit Millivolt To Propane 76 350DV CKNG Conversion Kit Millivolt To Natural Gas 76 350DV CKLPI2 Conversion Kit IPI To Propane 167 350DV CKNGI2 Conversion Kit IPI To Natural Gas 167 DOOR FRONTS: (REQUIRED FOR EACH UNIT) F35DB Door Frame and Ceramic Glass Black 625 LOG SET (REQUIRED FOR EACH UNIT) LOGF35 Log Set Fiber Split Oak (F350,F300,IDV33) 342 SAFETY BARRIER (REQUIRED FOR EACH UNIT) F35OCSS SAFETY BARRIER 250 ACCESSORIES: F45FK Fan Kit w/variable Speed Control (Temperature Sensing) 315 F45FK2 Fan Kit for Proflame 2, (Replacement) 288 F35RL Refractory Liner 155 F35BVC B Vent Converter (4/7" DV to 4" B Vent) 230 Z80PT Thermostat Programmable Digital Millivolt Wall Mount MV/PF1 150 GFRC Remote Control On/Off Millivolt 103

Page 4 FDV451 FREE STANDING DIRECT VENT GAS STOVE: Listed for USA/Canada as a Vented Gas Fireplace Heater, Dual Burner, Ceramic Glass, Glowing Embers, Hi/Lo SIT Valve, On/OFF Switch, 4/7" Flue, Black 34,500 BTU NG, 31,000 BTU Propane FDV451N Free Standing Stove (as above) Millivolt Natural Gas 1,754 FDV451LP Free Standing Stove (as above) Millivolt Propane 1,819 FDV451NE Free Standing Stove (as above) IPI Natural Gas 2,026 FDV451LPE Free Standing Stove (as above) IPI Propane 2,091 450DV CKLP Conversion Kit Millivolt To Propane 76 450DV CKNG Conversion Kit Millivolt To Natural Gas 76 450DV CKLPI Conversion Kit IPI To Propane 90 450DV CKNGI Conversion Kit IPI To Natural Gas 90 DOOR FRONTS: (REQUIRED FOR EACH UNIT) F450FBL Door Front and Vent Lid Charcoal with Flat Black Posts and Safety Screen 456 F450FSS Door Front and Vent Lid Charcoal with Stainless Posts and Safety Screen 523 SIDE DOORS: (REQUIRED FOR EACH UNIT) F451SDSBL Side Doors Black Frame Solid Panel Charcoal 293 F451SDSSS Side Doors Stainless Steel Frame Solid Panel Charcoal 417 LOG SET OR MEDIA: (REQUIRED FOR EACH UNIT) F45LG Log Grate FDV451/453 (Optional) 113 LOGF451 Log Set Oak 395 (Maximum Glass 15 lbs) Z5GC Glass Media 1/2" Bronze 5 lbs 90 RBCB1 Cannonballs Assorted size and colors 319 ACCESSORIES: F45FK Fan Kit w/variable Speed Control (Temperature Sensing) 315 F451RLT Refractory Liner Traditional 328 F451RLH Refractory Liner Herringbone 328 F451PL Porcelain Liner 3 Piece 439

Page 5 THERMOSTATS AND REMOTE CONTROLS GFRC Remote Control On/Off Millivolt 103 GTFRCN Remote Control Millivolt Thermostat/Modulating/Fan NG 537 GTFRCP Remote Control Millivolt Thermostat/Modulating/Fan LP 537 EGTRC Remote Control IPI Thermostat 310 EGTMRCN Remote Control IPI Thermostat/Modulating NG 421 EGTMRCP Remote Control IPI Thermostat/Modulating LP 421 EGTFRCN Remote Control IPI Thermostat/Modulating/Fan NG 567 EGTFRCP Remote Control IPI Thermostat/Modulating/Fan LP 567

Page 6 Horizontal Vent Starter Kit (Direct Vent Stoves) FDVHSK Termination, Wall Thimble, Black Wall Trim Plate, Mill Pac, Black Trim Rings, 542 7" x 24" Black Pipe, 7" x 48" Black Pipe, 90 Degree Elbow, 4" x 8' Flex Pipe, Vertical Vent Starter Kit (Direct Vent Stoves) FDVVSK Starter Kit Contains: Attic Insulation Shield, Fire Stop, Ceiling Trim Plate, 268 Black Trim Rings, Roof Support, Spacer Springs(6), Mill Pac Horizontal Venting FDVHT Horizontal Vent Termination 166 FDVHSQ Horizontal Square Vent Termination 206 FDVHSS Horizontal Stucco Shield 53 FDVHSCU Safety Cage Universal for Horizontal Termination 107 ZDVSS Siding Shield Heat Deflector for FDVHT Round Termination 24 ZDVSSLR Siding Shield Large Return for FDVHSQ or FDVHT 62 ZDVWT Wall Thimble (Horizontal Venting) 81 Z47ST24 Snorkel Termination 24" 616 Z47ST36 Snorkel Termination 36" 660 Z57STSC Safety Cage for Snorkel Termination 171 Vertical Venting FDVVT40 Vertical Vent Termination Convertible Between 15' & 40' Vertical 180 ZDVAIS Attic Insulation Shield 12" 89 Z7AIS24 Attic Insulation Shield 24" 118 ZDVVOS Offset Support 37 ZDVFS Fire stop Spacer 37 ZDVRS Roof Support 54 Z47GP36 Galvanized Pipe 4 and 7" Dia. x 36" (Vertical Installations) 202 Z47GP48 Galvanized Pipe 4 and 7" x 48" (Vertical Installations) 214 Flashings Vertical Venting ZDVAAF Flashing 7" c/w Storm Collar (1/12 to7/12) 75 ZDVAF2 Flashing 7" c/w Storm Collar (8/12 to 12/12) 101 ZDVAF3 Flashing 7" c/w Storm Collar Flat 98 ZDV7SC Storm Collar 7 Inch 19 Vent Pipe 7" and Flex Pipe 4" Clamps, Connectors FDV48P Black Pipe (7" Diameter x 48") 70 FDV36P Black Pipe (7" Diameter x 36") 64 FDV24P Black Pipe (7" Diameter x 24") 45 FDV12P Black Pipe (7" Diameter x 12") 30 FDVE90 Black Elbow (7" Diameter x 90 Degree) 45 FDVE45 Black Elbow (7" Diameter x 45 Degree) 45 ZDV4FP8 Flex Pipe 4" Diameter x 8 FT (Spacer Springs Not Included) 81 ZDV4FP20 Flex Pipe 4" Diameter x 20 FT (Spacer Springs Not Included) 187 ZDV4FC Flex Connector 4" Diameter 17 ZDV4FCL Flex Clamp 4" 13 ZDV4SS Spring 4" Standoff Spacer 13 Hard Pipe Adapter 4 x 6 5/8: ZDVDKA Dura Vent Stove Adapter (for Direct Vent Stoves) 86 7" Pipe Accessories F7DBC Decorative Black Collar 7" 33 F7DTP Decorative Black Wall Trim Plate 35

Page 7 ZDV3318 ZERO CLEARANCE DIRECT VENT GAS FIREPLACE 33" WIDE Listed for USA/Canada as a Vented Gas Fireplace, Pan Burner, SIT Valve with Hi/Lo, Wall Switch, 4/7" Sloped Top Flue, Tempered Glass, Safety Screen Framing Louvered 33 1/8" W x 31" H x 15 1/4" D ZDV3318N Fireplace, Millivolt Valve (as above) Natural Gas, 19,000 BTU $1,285 ZDV3318LP Fireplace, Millivolt Valve (as above) Propane, 18,000 BTU 1,342 ZDV3318NE Fireplace, IPI Valve (as above) Natural Gas, 19,000 BTU 1,563 ZDV3318LPE Fireplace, IPI Valve (as above) Propane, 18,000 BTU 1,621 3318 CKLP Conversion Kit Millivolt To Propane 76 3318 CKNG Conversion Kit Millivolt To Natural Gas 76 3318 CKLPI Conversion Kit IPI To Propane 90 3318 CKNGI Conversion Kit IPI To Natural Gas 90 LOG SET: (REQUIRED FOR EACH UNIT) LOGC50 Log Set Seven Piece Split Oak (ZDV3318/ 3622 Series) 171 GRILL KIT OR DESIGNER CLEAN VIEW KIT: (REQUIRED FOR EACH UNIT) Z33CVCK Designer Clean View Circulating Kit 348 VI30GBL Grill Kit Black 100 FIREPLACE ACCESSORY OPTIONS: Z3318ML Metal Brick Liner (3 PCE) 191 Z3318PRL Porcelain Reflective Panel Liner (3 PCE) 264 Z33FK Fan Kit w/variable Wall Mount Speed Control (Temperature Sensing) 309 Z33CSS Safety Screen Barrier 169 DECORATIVE SURROUNDS (For Louvered Units only) Z6SBL Surround Black 242 DECORATE THE BOTTOM OF YOUR FIREPLACE WITH LOG BITS: VLBIT4 Log Bits Large Four Piece Kit 111 VLBIT6 Log Bits Small Six Piece Kit 104 THERMOSTATS AND REMOTE CONTROLS DCHS Heat Shield Requiured for Millivolt Remote Receivers 17 EGTRC Remote Control IPI Thermostat 310 EGTMRCN Remote Control IPI Thermostat/Modulating NG 421 EGTMRCP Remote Control IPI Thermostat/Modulating LP 421

Page 8 ZCV3622 ZERO CLEARANCE CLEAN VIEW DIRECT VENT GAS FIREPLACE 36" WIDE Clean View Listed for USA/Canada, Includes: Tempered Glass, Tube Burner, SIT Valve with Hi/Lo Adjustment, Wall Switch, Safety Screen, 4/7" Flue. Framing 36 3/8 W x 37 1/4 H x 17 1/2"D ZCV3622N Fireplace, Millivolt Valve (as above) NG, 18,000 BTU $1,489 ZCV3622LP Fireplace, Millivolt Valve (as above) Propane 18,000 BTU 1,552 ZCV3622NE Fireplace, IPI Valve (as above) NG, 18,000 BTU 1,768 ZCV3622LPE Fireplace, IPI Valve (as above) Propane 18,000 BTU 1,831 3622 CKLP Conversion Kit Millivolt To Propane 76 3622 CKNG Conversion Kit Millivolt To Natural Gas 76 3622 CKLPI Conversion Kit IPI To Propane 90 3622 CKNGI Conversion Kit IPI To Natural Gas 90 LOG SET (REQUIRED FOR EACH UNIT) LOGC51 Log Set Split Oak (ZCV3622) 188 FIREPLACE ACCESSORIES OPTIONS: ZCV3622PRL Porcelain Reflective Panel Liner (3 PCE) 293 ZCV3622ML Metal Brick Liner (3 PCE) 196 Z36FK Fan Kit w/variable Speed Wall Mount Control (Temperature Sensing) 309 ZCV36CSS Safety Screen Barrier (Replacement) 214 ULK2 Universal Light Kit Two Lamps 262 ZCV36LMK Lower Panel Magnet Kit 23 DECORATE THE BOTTOM OF THE FIREPLACE VLBIT4 Log Bits Large Four Piece Kit 111 VLBIT6 Log Bits Small Six Piece Kit 104 SURROUND (Covers Framing Dimensions Unit must be installed flush to wall) ZCV36S1BL Surround Black (Coverage 34 1/16" H x 39" W) 242 THERMOSTATS AND REMOTE CONTROLS DCHS Heat Shield Requiured for Millivolt Remote Receivers 17 GTFRCN Remote Control Millivolt Thermostat/Modulating/Fan NG 537 EGTRC Remote Control IPI Thermostat 310 EGTMRCN Remote Control IPI Thermostat/Modulating NG 421 EGTMRCP Remote Control IPI Thermostat/Modulating LP 421

Page 9 ZCVRB3622 ZERO CLEARANCE CLEAN VIEW DIRECT VENT GAS FIREPLACE 36" Wide Listed for USA/Canada as a Vented Gas Fireplace, Includes: Linear Burner, Decorative Bronze Glass, SIT Valve with Hi/Lo Adjustment, Wall Switch, 4/7"Top Flue, Tempered Glass, Safety Screen, 17,500 BTU Framing 36 3/8 W x 37 1/4 H x 17 1/2"D ZCVRB3622N Fireplace Linear, Millivolt Valve (as above) Natural Gas $1,616 ZCVRB3622LP Fireplace Linear, Millivolt Valve (as above) Propane 1,681 ZCVRB3622NE Fireplace Linear, IPI Valve (as above) Natural Gas 1,900 ZCVRB3622LPE Fireplace Linear, IPI Valve (as above) Propane 1,965 3622RB CKLP Conversion Kit Millivolt To Propane 76 3622RB CKNG Conversion Kit Millivolt To Natural Gas 76 3622RB CKLPI Conversion Kit IPI To Propane 90 3622RB CKNGI Conversion Kit IPI To Natural Gas 90 SURROUND (COVERS 36" W X 22 1/2" H) (The fireplace must be covered up to an 1/8 of the opening with noncombustible materials) ZCVRB36SBL Surround Trim Kit 1 1/2" Wide Black 344 ZCVRB36SSS Surround Trim Kit 1 1/2" Wide Stainless Steel 575 FIREPLACE ACCESSORIES OPTIONS: ULK2 Universal Light Kit Two Lamps 262 Z3622PRL Porcelain Reflective Panel Liner (3 PCE) 293 Z36FK Fan Kit w/variable Speed Wall Mount Control (Temperature Sensing) 309 ZCVRB36CSS Safety Screen Barrier (Replacement) 201 THERMOSTATS AND REMOTE CONTROLS DCHS Heat Shield Requiured for Millivolt Remote Receivers 17 EGTRC Remote Control IPI Thermostat 310 EGTMRCN Remote Control IPI Thermostat/Modulating NG 421 EGTMRCP Remote Control IPI Thermostat/Modulating LP 421

Page 10 HB3624 ZERO CLEARANCE DIRECT VENT GAS FIREPLACE 36" WIDE Listed for USA/Canada as a Vented Gas Fireplace, Dual Burner, SIT Valve with Hi/Lo, Wall Switch, 4/7" Sloped Top Flue, Tempered Glass, Safety Screen Framing Louvered 36 3/8" W x 35" H x 17" D HBZDV3624N Fireplace, Millivolt Valve (as above) Natural Gas, 24,000 BTU $1,633 HBZDV3624LP Fireplace, Millivolt Valve (as above) Propane, 22,000 BTU 1,705 HBZDV3624NE Fireplace, IPI Valve (as above) Natural Gas, 24,000 BTU 1,911 HBZDV3624LPE Fireplace, IPI Valve (as above) Propane, 22,000 BTU 1,986 3624HB CKLP Conversion Kit Millivolt To Propane 76 3624HB CKNG Conversion Kit Millivolt To Natural Gas 76 3624HB CKLPI Conversion Kit IPI To Propane 90 3624HB CKNGI Conversion Kit IPI To Natural Gas 90 LOG SET: (REQUIRED FOR EACH UNIT) LOGC42 Log Set Four Piece Classic Oak (3320, 3624/28, 4224/28 Series) 142 LOGC43 Log Set Four Piece Traditional Oak (3320, 3624/28, 4224/28 Series) 171 LOGC44 Log Set Eight Piece Burnt Oak (3320, 3624/28, 4224/28 Series) 171 GRILL KIT OR DESIGNER CLEAN VIEW KIT: (REQUIRED FOR EACH UNIT) HB36CVCK Designer Clean View Circulating Kit 348 HB36GBL Grill Kit Black 86 FIREPLACE ACCESSORIES OPTIONS: HB36RLT Refractory Fiber Brick Liner (3 PCE) Traditional 201 HB36RRH Refractory Fiber Brick Liner (3 PCE) Red Herringbone 201 HB36RLH Refractory Fiber Brick Liner (3 PCE) Herringbone 201 HB36PL Porcelain Reflective Panel Liner (3 PCE) 442 Z36FK Fan Kit w/variable Speed Wall Mount Control (Temperature Sensing) 309 HB36CSS Safety Screen Barrier (Replacement) 214 HB36SBL Surround Black (For Louvered Unit Only) 242 DECORATE THE BOTTOM OF YOUR FIREPLACE WITH LOG BITS: VLBIT4 Log Bits Large Four Piece Kit 111 VLBIT6 Log Bits Small Six Piece Kit 104 THERMOSTATS AND REMOTE CONTROLS GTFRCN Remote Control Millivolt Thermostat/Modulating/Fan NG 537 GTFRCP Remote Control Millivolt Thermostat/Modulating/Fan LP 537 EGTRC Remote Control IPI Thermostat 310 EGTMRCN Remote Control IPI Thermostat/Modulating NG 421 EGTMRCP Remote Control IPI Thermostat/Modulating LP 421 EGTFRCN Remote Control IPI Thermostat/Modulating/Fan NG 567 EGTFRCP Remote Control IPI Thermostat/Modulating/Fan LP 567

Page 11 HB3628 ZERO CLEARANCE DIRECT VENT GAS FIREPLACE 36" WIDE Listed for USA/Canada as a Vented Gas Fireplace Heater, SIT Valve with Hi/Lo, Wall Switch, 4/7" Sloped Top Flue, Ceramic Glass, Safety Screen Framing Louvered 36 3/8" W x 35" H x 17" D HBZDV3628N Fireplace, Millivolt Valve (as above) Natural Gas, 28,000 BTU $2,301 HBZDV3628LP Fireplace, Millivolt Valve (as above) Propane, 26,000 BTU 2,334 HBZDV3628NE Fireplace, IPI Valve (as above) Natural Gas, 28,000 BTU 2,581 HBZDV3628LPE Fireplace Heater, IPI Valve (as above) Propane, 26,000 BTU 2,613 3628HB CKLP Conversion Kit Millivolt To Propane 76 3628HB CKNG Conversion Kit Millivolt To Natural Gas 76 3628HB CKLPI Conversion Kit IPI To Propane 90 3628HB CKNGI Conversion Kit IPI To Natural Gas 90 LOG SET: (REQUIRED FOR EACH UNIT) LOGC42 Log Set Four Piece Classic Oak (3320, 3624/28, 4224/28 Series) 142 LOGC43 Log Set Four Piece Traditional Oak (3320, 3624/28, 4224/28 Series) 171 LOGC44 Log Set Eight Piece Burnt Oak (3320, 3624/28, 4224/28 Series) 171 GRILL KIT OR DESIGNER CLEAN VIEW KIT: (REQUIRED FOR EACH UNIT) HB36CVCK Designer Clean View Circulating Kit 348 HB36GBL Grill Kit Black 86 FIREPLACE ACCESSORIES OPTIONS: HB36RLT Refractory Fiber Brick Liner (3 PCE) Traditional 201 HB36RRH Refractory Fiber Brick Liner (3 PCE) Red Herringbone 201 HB36RLH Refractory Fiber Brick Liner (3 PCE) Herringbone 201 HB36PL Porcelain Reflective Panel Liner (3 PCE) 442 Z36FK Fan Kit w/variable Speed Wall Mount Control (Temperature Sensing) 309 HB36CSS Safety Screen Barrier (Replacement) 214 HB36SBL Surround Black (For Louvered Unit Only) 242 DECORATE THE BOTTOM OF YOUR FIREPLACE WITH LOG BITS: VLBIT4 Log Bits Large Four Piece Kit 111 VLBIT6 Log Bits Small Six Piece Kit 104 THERMOSTATS AND REMOTE CONTROLS GTFRCN Remote Control Millivolt Thermostat/Modulating/Fan NG 537 GTFRCP Remote Control Millivolt Thermostat/Modulating/Fan LP 537 EGTRC Remote Control IPI Thermostat 310 EGTMRCN Remote Control IPI Thermostat/Modulating NG 421 EGTMRCP Remote Control IPI Thermostat/Modulating LP 421 EGTFRCN Remote Control IPI Thermostat/Modulating/Fan NG 567 EGTFRCP Remote Control IPI Thermostat/Modulating/Fan LP 567

Page 12 HB4224 ZERO CLEARANCE DIRECT VENT GAS FIREPLACE 42" WIDE: Listed for USA/Canada as a Vented Gas Fireplace, Dual Burner, SIT Valve with Hi/Lo, Wall Switch, 4/7" Sloped Top Flue, Tempered Glass, Safety Screen Framing Louvered 42 3/8" W x 37 1/4" H x 17" D HBZDV4224N Fireplace, Millivolt Valve (as above) Natural Gas, 24,000 BTU $1,882 HBZDV4224LP Fireplace, Millivolt Valve (as above) Propane, 22,000 BTU 1,924 HBZDV4224NE Fireplace, IPI Valve (as above) Natural Gas, 24,000 BTU 2,161 HBZDV4224LPE Fireplace, IPI Valve (as above) Propane, 22,000 BTU 2,202 4224HB CKLP Conversion Kit Millivolt To Propane 76 4224HB CKNG Conversion Kit Millivolt To Natural Gas 76 4224HB CKLPI Conversion Kit IPI To Propane 90 4224HB CKNGI Conversion Kit IPI To Natural Gas 90 LOG SET: (REQUIRED FOR EACH UNIT) LOGC42 Log Set Four Piece Classic Oak (3320, 3624/28, 4224/28 Series) 142 LOGC43 Log Set Four Piece Traditional Oak (3320, 3624/28, 4224/28 Series) 171 LOGC44 Log Set Eight Piece Burnt Oak (3320, 3624/28, 4224/28 Series) 171 GRILL KIT OR DESIGNER CLEAN VIEW KIT: (REQUIRED FOR EACH UNIT) HB42CVCK Designer Clean View Circulating Kit 383 HB42GBL Grill Kit Black 95 FIREPLACE ACCESSORIES OPTIONS: HB42RLT Refractory Fiber Brick Liner (3 PCE) Traditional 230 HB42RRH Refractory Fiber Brick Liner (3 PCE) Red Herringbone 230 HB42RLH Refractory Fiber Brick Liner (3 PCE) Herringbone 230 HB42PL Porcelain Reflective Panel Liner (3 PCE) 487 Z36FK Fan Kit w/variable Speed Wall Mount Control (Temperature Sensing) 309 HB42CSS Safety Screen Barrier (Replacement) 223 HB42SBL Surround Black (For Louvered Unit Only) 255 DECORATE THE BOTTOM OF YOUR FIREPLACE WITH LOG BITS: VLBIT4 Log Bits Large Four Piece Kit 111 VLBIT6 Log Bits Small Six Piece Kit 104 THERMOSTATS AND REMOTE CONTROLS GTFRCN Remote Control Millivolt Thermostat/Modulating/Fan NG 537 GTFRCP Remote Control Millivolt Thermostat/Modulating/Fan LP 537 EGTRC Remote Control IPI Thermostat 310 EGTMRCN Remote Control IPI Thermostat/Modulating NG 421 EGTMRCP Remote Control IPI Thermostat/Modulating LP 421 EGTFRCN Remote Control IPI Thermostat/Modulating/Fan NG 567 EGTFRCP Remote Control IPI Thermostat/Modulating/Fan LP 567

Page 13 HB4228 ZERO CLEARANCE DIRECT VENT GAS FIREPLACE 42" WIDE Listed for USA/Canada as a Vented Gas Fireplace, Dual Burner, SIT Valve with Hi/Lo, Wall Switch, 4/7" Sloped Top Flue, Ceramic Glass, Safety Screen Framing Louvered 42 3/8" W x 37 1/4" H x 17" D HBZDV4228N Fireplace, Millivolt Valve (as above) Natural Gas, 28,000 BTU $2,841 HBZDV4228LP Fireplace, Millivolt Valve (as above) Propane, 26,000 BTU 2,891 HBZDV4228NE Fireplace, IPI Valve (as above) Natural Gas, 28,000 BTU 3,120 HBZDV4228LPE Fireplace, IPI Valve (as above) Propane, 26,000 BTU 3,171 4228HB CKLP Conversion Kit Millivolt To Propane 76 4228HB CKNG Conversion Kit Millivolt To Natural Gas 76 4228HB CKLPI Conversion Kit IPI To Propane 90 4228HB CKNGI Conversion Kit IPI To Natural Gas 90 LOG SET: (REQUIRED FOR EACH UNIT) LOGC42 Log Set Four Piece Classic Oak (3320, 3624/28, 4224/28 Series) 142 LOGC43 Log Set Four Piece Traditional Oak (3320, 3624/28, 4224/28 Series) 171 LOGC44 Log Set Eight Piece Burnt Oak (3320, 3624/28, 4224/28 Series) 171 GRILL KIT OR DESIGNER CLEAN VIEW KIT: (REQUIRED FOR EACH UNIT) HB42CVCK Designer Clean View Circulating Kit 383 HB42GBL Grill Kit Black 95 FIREPLACE ACCESSORIES OPTIONS: HB42RLT Refractory Fiber Brick Liner (3 PCE) Traditional 230 HB42RLH Refractory Fiber Brick Liner (3 PCE) Herringbone 230 HB42RRH Refractory Fiber Brick Liner (3 PCE) Red Herringbone 230 HB42PL Porcelain Reflective Panel Liner (3 PCE) 487 Z36FK Fan Kit w/variable Speed Wall Mount Control (Temperature Sensing) 309 HB42CSS Safety Screen Barrier (Replacement) 223 HB42SBL Surround Black (For Louvered Units only) 255 DECORATE THE BOTTOM OF YOUR FIREPLACE WITH LOG BITS: VLBIT4 Log Bits Large Four Piece Kit 111 VLBIT6 Log Bits Small Six Piece Kit 104 THERMOSTATS AND REMOTE CONTROLS GTFRCN Remote Control Millivolt Thermostat/Modulating/Fan NG 537 GTFRCP Remote Control Millivolt Thermostat/Modulating/Fan LP 537 EGTRC Remote Control IPI Thermostat 310 EGTMRCN Remote Control IPI Thermostat/Modulating NG 421 EGTMRCP Remote Control IPI Thermostat/Modulating LP 421 EGTFRCN Remote Control IPI Thermostat/Modulating/Fan NG 567 EGTFRCP Remote Control IPI Thermostat/Modulating/Fan LP 567

Page 14 HB4736 ZERO CLEARANCE DIRECT VENT GAS FIREPLACES 47" WIDE Listed for USA/Canada, Dual Burner, Milli Volt Sit Valve with Hi/Lo Adjustment Wall Switch, Tempered Glass, Safety Screen, Four/Seven Sloped Flue, Framing (Louvered) 47 3/8" W x 43 1/8" H x 19 1/2" D ZERO CLEARANCE CLEAN VIEW DIRECT VENT GAS FIREPLACE HBZDV4736N Fireplace, Millivolt (as above) NG, 40,000 BTU $2,483 HBZDV4736LP Fireplace, Millivolt (as above) LP, 36,000 BTU 2,559 HBZDV4736NE Fireplace, IPI (as above) NG, 40,000 BTU 2,762 HBZDV4736LPE Fireplace, IPI (as above) LP, 36,000 BTU 2,840 4740HB CKLP Conversion Kit Millivolt To Propane 76 4740HB CKNG Conversion Kit Millivolt To Natural Gas 76 4740HB CKLPI Conversion Kit IPI To Propane 90 4740HB CKNGI Conversion Kit IPI To Natural Gas 90 LOG SET (REQUIRED FOR EACH UNIT) LOGF36 Log Set Fiber Split Oak 457 GRILL KIT OR DESIGNER CLEAN VIEW KIT: (REQUIRED FOR EACH UNIT) HB47CVCK Designer Clean View Circulating Kit 432 HB47GBL Grill Kit Black 111 OPTIONAL BRICK OR PORCELAIN LINERS HB47RLT Refractory Fiber Brick Liner (4 PCE) Traditional 379 HB47RLH Refractory Fiber Brick Liner (4 PCE) Herringbone 379 HB47RRH Refractory Fiber Brick Liner (4 PCE) Red Herringbone 379 HB47PL Porcelain Reflective Panel Liner (3 PCE) 692 OPTIONAL FIREPLACE ACCESSORIES Z36FK Fan Kit w/variable Speed Wall Mount Control (Temperature Sensing) 309 HB47CSS Safety Screen Barrier (Replacement) 255 DECORATE THE BOTTOM OF YOUR FIREPLACE WITH LOG BITS: VLBIT4 Log Bits Large Four Piece Kit 111 VLBIT6 Log Bits Small Six Piece Kit 104 OPTIONAL THERMOSTATS AND REMOTE CONTROLS GTFRCN Remote Control Millivolt Thermostat/Modulating/Fan NG 537 GTFRCP Remote Control Millivolt Thermostat/Modulating/Fan LP 537 EGTRC Remote Control IPI PF1 Thermostat 310 EGTMRCN Remote Control IPI PF1 Thermostat/Modulating NG 421 EGTMRCP Remote Control IPI PF1 Thermostat/Modulating LP 421 EGTFRCN Remote Control IPI PF1 Thermostat/Modulating/Fan NG 567 EGTFRCP Remote Control IPI PF1 Thermostat/Modulating/Fan LP 567

Page 15 VRB46 ZERO CLEARANCE DIRECT VENT GAS FIREPLACE 46" WIDE Listed for USA/Canada as a Vented Gas Fireplace Heater, Includes: Linear Burner, Bronze Glass Media, SIT Valve with Hi/Lo Adjustment, Wall Switch, 4/7" Top Flue, Tempered Glass 40 5/8 W x 13 7/8" H, Safety Screen Framing 46 3/4" W x 43 1/2" H x 18" D, 23,000 BTU, Max Glass Media 5 LBS The Fireplace Enclosure May Be Ventilated for TV Installations, Cool Touch Walls, and reduced Mantel Clearances. Ventilation up to 105 Sq/Inches will be required. Minimum Enclosure Height is 70", see Manual for details. For use with with Kingsman Flex Vent only. VRB46N Fireplace Linear, Millivolt Valve (as above) Natural Gas $3,219 VRB46LP Fireplace Linear, Millivolt Valve (as above) Propane 3,265 VRB46NE Fireplace Linear, IPI Valve (as above) Natural Gas 3,468 VRB46LPE Fireplace Linear, IPI Valve (as above) Propane 3,518 46ZRB CKLP Conversion Kit Millivolt To Propane 76 46ZRB CKNG Conversion Kit Millivolt To Natural Gas 76 46ZRB CKLPI Conversion Kit IPI To Propane 90 46ZRB CKNGI Conversion Kit IPI To Natural Gas 90 Required When Ventilating Enclosure Ventilation up to 105 Sq./Inches Choose V46EG Grill or Custom Grill or adequate ventilation as per manual V46EG Grill for Enclosure 46 9/16" W x 2 1/2" H unfinished 175 WALL SURROUND (COVERS 44 5/8"W X 17 1/8"H) ZRB46S1BL Surround Trim Kit 1 1/2" Wide Black 344 ZRB46S1SS Surround Trim Kit 1 1/2" Wide Stainless Steel 575 WALL SURROUND (COVERS 50 1/2"W X 22 1/2"H) ZRB46S2BL Surround Trim Kit 4" Wide Black 522 ZRB46S2SS Surround Trim Kit 4" Wide Stainless Steel 986 FIREPLACE ACCESSORIES OPTIONS: ULK2 Universal Light Kit Two Lamps 262 VRB46PL Porcelain Reflective Panel Liner (3 PCE) (for VRB46 Model Only) 406 Z46FK Fan Kit w/variable Speed Wall Mount Control (Temperature Sensing) 309 ZRB46CSS Safety Screen Barrier (Replacement) 269 RBCB1 Cannonballs Assorted size and colors 319 V46PTLK Tile Lip Kit for Promat Board 60 Z46PRO4 Promat Board ZRB46 4 Pce Kit 315 THERMOSTATS AND REMOTE CONTROLS GTFRCN Remote Control Millivolt Thermostat/Modulating/Fan NG 537 GTFRCP Remote Control Millivolt Thermostat/Modulating/Fan LP 537 EGTRC Remote Control IPI Thermostat 310 EGTMRCN Remote Control IPI Thermostat/Modulating NG 421 EGTMRCP Remote Control IPI Thermostat/Modulating LP 421 EGTFRCN Remote Control IPI Thermostat/Modulating/Fan NG 567 EGTFRCP Remote Control IPI Thermostat/Modulating/Fan LP 567

Page 16 ZCV39 ZERO CLEARANCE CLEAN VIEW DIRECT VENT GAS FIREPLACE 39" WIDE Listed for USA/Canada as a Decorative Vented Gas Fireplace, SIT Valve with Hi/Lo Flame Adjustment, Wall Switch, 4/7" Sloped Top Flue, Tempered Glass Viewing Area 29 5/8" W x 24 1/8" H, Safety Screen, Framing 39 1/2" W x 37 7/8" H x 18 1/2" D ZCV39N Fireplace, Millivolt Valve (as above) Natural Gas, 25,000 BTU $1,887 ZCV39LP Fireplace, Millivolt Valve (as above) Propane, 25,000 BTU 1,957 ZCV39NE Fireplace, IPI Valve (as above) Natural Gas, 25,000 BTU 2,164 ZCV39LPE Fireplace, IPI Valve (as above) Propane, 25,000 BTU 2,233 39ZCV CKLP Conversion Kit Millivolt To Propane 76 39ZCV CKNG Conversion Kit Millivolt To Natural Gas 76 39ZCV CKLPI Conversion Kit IPI To Propane 90 39ZCV CKNGI Conversion Kit IPI To Natural Gas 90 LOG SET OR GLASS TRAY AND MEDIA: (REQUIRED FOR EACH UNIT) LOGC3 Log Set Five Piece Glo Cast ZCV39/42 221 LOGF3 Log Set Five Piece Fiber ZCV39/42 291 ZCV39GT Glass Tray for ZCV39 (Requires 15 lbs of Glass Media) 146 Z5GC Glass Media 1/2" Bronze 5 lbs 90 RBCB1 Cannonballs Assorted size and colors 319 ULK2 Universal Light Kit Two Lamps (for use with ZCV39/42GT Glass Tray) 262 39ZCV 258 Pilot Shield for ZCV39/42GT (Replacement Part) 47 SURROUNDS AND SAFETY SCREEN ZCV39S1BL Surround Hearth Mount 4" Wide (Covers 40 5/8" W x 35" H) 349 ZCV39S1PFBL Surround Picture Frame 4" Wide (Covers 40 5/8" W x 37" H) 349 ZCV39S2PFBL Surround Picture Frame 1 5/8" Wide (Covers 36 1/8" W x 32 1/2" H) 319 ZCV39CSS Safety Screen Barrier Outside Fit (Replacement) 269 ZCV39CSS2 Safety Screen Barrier Inside Fit (Replacement) 269 FIREPLACE ACCESSORIES OPTIONS: ZCV39RLT Refractory Fiber Brick Liner (3 PCE) Traditional 291 ZCV39RLH Refractory Fiber Brick Liner (3 PCE) Herringbone 291 ZCV39RRH Refractory Fiber Brick Liner (3 PCE) Red Herringbone 291 ZCV39RLS Refractory Fiber Brick Liner (3 PCE) Stacked Brick 291 ZCV39PL Porcelain Reflective Panel Liner (3 PCE) 480 Z46FK Fan Kit w/variable Speed Wall Mount Control (Temperature Sensing) 309 ZCV TLK Tile Lip Kit (for Finishing Materials tile, brick) 59 DECORATE THE BOTTOM OF YOUR FIREPLACE WITH LOG BITS: VLBIT4 Log Bits Large Four Piece Kit 111 VLBIT6 Log Bits Small Six Piece Kit 104

Page 17 THERMOSTATS AND REMOTE CONTROLS GTFRCN Remote Control Millivolt Thermostat/Modulating/Fan NG 537 GTFRCP Remote Control Millivolt Thermostat/Modulating/Fan LP 537 EGTRC Remote Control IPI Thermostat 310 EGTMRCN Remote Control IPI Thermostat/Modulating NG 421 EGTMRCP Remote Control IPI Thermostat/Modulating LP 421 EGTFRCN Remote Control IPI Thermostat/Modulating/Fan NG 567 EGTFRCP Remote Control IPI Thermostat/Modulating/Fan LP 567

Page 18 ZCV39H ZERO CLEARANCE CLEAN VIEW DIRECT VENT GAS FIREPLACE 39" WIDE Listed for USA/Canada as a Vented Gas Fireplace Heater, SIT Valve with Hi/Lo Flame Adjustment, Wall Switch, 4/7" Sloped Top Flue, Ceramic Glass Viewing Area 29 5/8" W x 24 1/8" H, Safety Screen, Framing 39 1/2" W x 37 7/8" H x 18 1/2" D ZCV39NH Fireplace Heater, Millivolt Valve (as above) Natural Gas, 28,000 BTU $2,511 ZCV39LPH Fireplace Heater, Millivolt Valve (as above) Propane, 29,000 BTU 2,580 ZCV39NHE Fireplace Heater, IPI Valve (as above) Natural Gas, 28,000 BTU 2,789 ZCV39LPHE Fireplace Heater, IPI Valve (as above) Propane, 29,000 BTU 2,858 39ZCV CKLPH Conversion Kit Millivolt To Propane 76 39ZCV CKNGH Conversion Kit Millivolt To Natural Gas 76 39ZCV CKLPHI Conversion Kit IPI To Propane 90 39ZCV CKNHI Conversion Kit IPI To Natural Gas 90 LOG SET OR GLASS TRAY AND MEDIA: (REQUIRED FOR EACH UNIT) LOGC3 Log Set Five Piece Glo Cast ZCV39/42 221 LOGF3 Log Set Five Piece Fiber ZCV39/42 291 ZCV39GT Glass Tray for ZCV39 (Requires 15 lbs of Glass Media) 146 Z5GC Glass Media 1/2" Bronze 5 lbs 90 RBCB1 Cannonballs Assorted size and colors 319 ULK2 Universal Light Kit Two Lamps (for use with ZCV39/42GT Glass Tray) 262 39ZCV 258 Pilot Shield for ZCV39/42GT (Replacement Part) 47 SURROUNDS AND SAFETY SCREEN ZCV39S1BL Surround Hearth Mount 4" Wide (Covers 40 5/8" W x 35" H) 349 ZCV39S1PFBL Surround Picture Frame 4" Wide (Covers 40 5/8" W x 37" H) 349 ZCV39S2PFBL Surround Picture Frame 1 5/8" Wide (Covers 36 1/8" W x 32 1/2" H) 319 ZCV39CSS Safety Screen Barrier Outside Fit (Replacement) 269 ZCV39CSS2 Safety Screen Barrier Inside Fit (Replacement) 269 FIREPLACE ACCESSORIES OPTIONS: ZCV39RLT Refractory Fiber Brick Liner (3 PCE) Traditional 291 ZCV39RLH Refractory Fiber Brick Liner (3 PCE) Herringbone 291 ZCV39RRH Refractory Fiber Brick Liner (3 PCE) Red Herringbone 291 ZCV39RLS Refractory Fiber Brick Liner (3 PCE) Stacked Brick 291 ZCV39PL Porcelain Reflective Panel Liner (3 PCE) 480 Z46FK Fan Kit w/variable Speed Wall Mount Control (Temperature Sensing) 309 ZCV TLK Tile Lip Kit (for Finishing Materials tile, brick) 59 DECORATE THE BOTTOM OF YOUR FIREPLACE WITH LOG BITS: VLBIT4 Log Bits Large Four Piece Kit 111 VLBIT6 Log Bits Small Six Piece Kit 104

Page 19 THERMOSTATS AND REMOTE CONTROLS GTFRCN Remote Control Millivolt Thermostat/Modulating/Fan NG 537 GTFRCP Remote Control Millivolt Thermostat/Modulating/Fan LP 537 EGTRC Remote Control IPI Thermostat 310 EGTMRCN Remote Control IPI Thermostat/Modulating NG 421 EGTMRCP Remote Control IPI Thermostat/Modulating LP 421 EGTFRCN Remote Control IPI Thermostat/Modulating/Fan NG 567 EGTFRCP Remote Control IPI Thermostat/Modulating/Fan LP 567

Page 20 ZCV42 ZERO CLEARANCE CLEAN VIEW DIRECT VENT GAS FIREPLACE 42" Wide Listed for USA/Canada as a Decorative Vented Gas Fireplace, SIT Valve with Hi/Lo Flame Adjustment, Wall Switch, 4/7" Sloped Top Flue, Tempered Glass Viewing Area 33 5/8" W x 27 1/4" H, Safety Screen, Framing 42 1/2" W x 41" H x 18 1/2" D ZCV42N Fireplace, Millivolt Valve (as above) Natural Gas, 25,000 BTU $2,128 ZCV42LP Fireplace, Millivolt Valve (as above) Propane, 25,000 BTU 2,199 ZCV42NE Fireplace, IPI Valve (as above) Natural Gas, 25,000 BTU 2,407 ZCV42LPE Fireplace, IPI Valve (as above) Propane, 25,000 BTU 2,477 42ZCV CKLP Conversion Kit Millivolt To Propane 76 42ZCV CKNG Conversion Kit Millivolt To Natural Gas 76 42ZCV CKLPI Conversion Kit IPI To Propane 90 42ZCV CKNGI Conversion Kit IPI To Natural Gas 90 LOG SET OR GLASS TRAY AND MEDIA: (REQUIRED FOR EACH UNIT) LOGC3 Log Set Five Piece Glo Cast ZCV39/42 221 LOGF3 Log Set Five Piece Fiber ZCV39/42 291 ZCV42GT Glass Tray for ZCV42 (Requires 20 lbs of Glass Media) 154 Z5GC Glass Media 1/2" Bronze 5 lbs 90 RBCB1 Cannonballs Assorted size and colors 319 ULK2 Universal Light Kit Two Lamps (for use with ZCV39/42GT Glass Tray) 262 39ZCV 258 Pilot Shield for ZCV39/42GT (Replacement Part) 47 SURROUNDS AND SAFETY SCREEN ZCV42S1BL Surround Hearth Mount 4" Wide (Covers 44 5/8" W x 38 1/8" H) 396 ZCV42S1PFBL Surround Picture Frame 4" Wide (Covers 44 5/8" W x 40 1/8" H) 396 ZCV42S2PFBL Surround Picture Frame 1 5/8" Wide (Covers 40 1/8" W x 35 5/8" H) 349 ZCV42CSS Safety Screen Barrier Outside Fit (Replacement) 304 ZCV42CSS2 Safety Screen Barrier Inside Fit (Replacement) 304 FIREPLACE ACCESSORIES OPTIONS: ZCV42RLT Refractory Fiber Brick Liner (3 PCE) Traditional 319 ZCV42RLH Refractory Fiber Brick Liner (3 PCE) Herringbone 319 ZCV42RRH Refractory Fiber Brick Liner (3 PCE) Red Herringbone 319 ZCV42RLS Refractory Fiber Brick Liner (3 PCE) Stacked Brick 319 ZCV42PL Porcelain Reflective Panel Liner (3 PCE) 515 Z46FK Fan Kit w/variable Speed Wall Mount Control (Temperature Sensing) 309 ZCV TLK Tile Lip Kit (for Finishing Materials tile, brick) 59 DECORATE THE BOTTOM OF YOUR FIREPLACE WITH LOG BITS: VLBIT4 Log Bits Large Four Piece Kit 111 VLBIT6 Log Bits Small Six Piece Kit 104

Page 21 THERMOSTATS AND REMOTE CONTROLS GTFRCN Remote Control Millivolt Thermostat/Modulating/Fan NG 537 GTFRCP Remote Control Millivolt Thermostat/Modulating/Fan LP 537 EGTRC Remote Control IPI Thermostat 310 EGTMRCN Remote Control IPI Thermostat/Modulating NG 421 EGTMRCP Remote Control IPI Thermostat/Modulating LP 421 EGTFRCN Remote Control IPI Thermostat/Modulating/Fan NG 567 EGTFRCP Remote Control IPI Thermostat/Modulating/Fan LP 567

Page 22 ZCV42H ZERO CLEARANCE CLEAN VIEW DIRECT VENT GAS FIREPLACE 42" Wide Listed for USA/Canada as a Vented Gas Fireplace Heater, SIT Valve with Hi/Lo Flame Adjustment, Wall Switch, 4/7" Sloped Top Flue, Ceramic Glass Viewing Area 33 5/8" W x 27 1/4" H, Safety Screen, Framing 42 1/2" W x 41" H x 18 1/2" D ZCV42NH Fireplace Heater, Millivolt Valve (as above) Natural Gas, 29,500 BTU $3,079 ZCV42LPH Fireplace Heater, Millivolt Valve (as above) Propane, 29,000 BTU 3,148 ZCV42NHE Fireplace Heater, IPI Valve (as above) Natural Gas, 29,500 BTU 3,356 ZCV42LPHE Fireplace Heater, IPI Valve (as above) Propane, 29,000 BTU 3,425 42ZCV CKLPH Conversion Kit Millivolt To Propane 76 42ZCV CKNGH Conversion Kit Millivolt To Natural Gas 76 42ZCV CKLPHI Conversion Kit IPI To Propane 90 42ZCV CKNGHI Conversion Kit IPI To Natural Gas 90 LOG SET OR GLASS TRAY AND MEDIA: (REQUIRED FOR EACH UNIT) LOGC3 Log Set Five Piece Glo Cast ZCV39/42 221 LOGF3 Log Set Five Piece Fiber ZCV39/42 291 ZCV42GT Glass Tray for ZCV42 (Requires 20 lbs of Glass Media) 154 Z5GC Glass Media 1/2" Bronze 5 lbs 90 RBCB1 Cannonballs Assorted size and colors 319 ULK2 Universal Light Kit Two Lamps (for use with ZCV39/42GT Glass Tray) 262 39ZCV 258 Pilot Shield for ZCV39/42GT (Replacement Part) 47 SURROUNDS AND SAFETY SCREEN ZCV42S1BL Surround Hearth Mount 4" Wide (Covers 44 5/8" W x 38 1/8" H) 396 ZCV42S1PFBL Surround Picture Frame 4" Wide (Covers 44 5/8" W x 40 1/8" H) 396 ZCV42S2PFBL Surround Picture Frame 1 5/8" Wide (Covers 40 1/8" W x 35 5/8" H) 349 ZCV42CSS Safety Screen Barrier Outside Fit (Replacement) 304 ZCV42CSS2 Safety Screen Barrier Inside Fit (Replacement) 304 FIREPLACE ACCESSORIES OPTIONS: ZCV42RLT Refractory Fiber Brick Liner (3 PCE) Traditional 319 ZCV42RLH Refractory Fiber Brick Liner (3 PCE) Herringbone 319 ZCV42RRH Refractory Fiber Brick Liner (3 PCE) Red Herringbone 319 ZCV42RLS Refractory Fiber Brick Liner (3 PCE) Stacked Brick 319 ZCV42PL Porcelain Reflective Panel Liner (3 PCE) 515 Z46FK Fan Kit w/variable Speed Wall Mount Control (Temperature Sensing) 309 ZCV TLK Tile Lip Kit (for Finishing Materials tile, brick) 59 DECORATE THE BOTTOM OF YOUR FIREPLACE WITH LOG BITS: VLBIT4 Log Bits Large Four Piece Kit 111 VLBIT6 Log Bits Small Six Piece Kit 104

Page 23 THERMOSTATS AND REMOTE CONTROLS GTFRCN Remote Control Millivolt Thermostat/Modulating/Fan NG 537 GTFRCP Remote Control Millivolt Thermostat/Modulating/Fan LP 537 EGTRC Remote Control IPI Thermostat 310 EGTMRCN Remote Control IPI Thermostat/Modulating NG 421 EGTMRCP Remote Control IPI Thermostat/Modulating LP 421 EGTFRCN Remote Control IPI Thermostat/Modulating/Fan NG 567 EGTFRCP Remote Control IPI Thermostat/Modulating/Fan LP 567

Page 24 MDV31 MULTI SIDED DIRECT VENT FIREPLACE: SERIES Listed for USA/Canada as a Vented Gas Fireplace: Triple Burner, SIT Valve Hi/Lo Wall Switch, Tempered Glass, Safety Screen, 4/7" Sloped Top Flue, 30,000 BTU MDVR31N Multi Sided Fireplace, Right Burner, Millivolt Valve (as above) Natural Gas $2,967 MDVR31LP Multi Sided Fireplace, Right Burner, Millivolt Valve (as above) Propane 3,045 MDVR31NE Multi Sided Fireplace, RH Burner, IPI Valve (as above) Natural Gas 3,246 MDVR31LPE Multi Sided Fireplace, RH Burner, IPI Valve (as above) Propane 3,324 MDVL31N Multi Sided Fireplace, Left Burner, Millivolt Valve (as above) Natural Gas 2,967 MDVL31LP Multi Sided Fireplace, Left Burner, Millivolt Valve (as above) Propane 3,045 MDVL31NE Multi Sided Fireplace, LH Burner, IPI Valve (as above) Natural Gas 3,246 MDVL31LPE Multi Sided Fireplace, LH Burner, IPI Valve (as above) Propane 3,324 31MDV CKLP Conversion Kit Millivolt To Propane 76 31MDV CKNG Conversion Kit Millivolt To Natural Gas 76 31MDV CKLPI Conversion Kit IPI To Propane 90 31MDV CKNGI Conversion Kit IPI To Natural Gas 90 LOG SET: (REQUIRED FOR EACH UNIT) LOGC31 Log Set Seven Piece Cast Split Oak (for GLMVF40 or MDV31) 391 CHOOSE YOUR VIEW KIT AND GRILL KIT: (REQUIRED FOR EACH UNIT) M30PK Peninsula Kit Tempered 1x Large Glass,1x Small Glass and Safety Screens 827 MGPKBL Grill Kit Peninsula Black (Three Sets) 228 M30CK Corner Kit Tempered Glass, Shield & Panel, Safety Screens 775 MGCKBL Grill Kit Corner Black (Two Sets) 147 M30SK See Through Kit Tempered Glass, Shield & Panel, Safety Screen 730 GRILL KIT OR DESIGNER CLEAN VIEW KIT: (REQUIRED FOR EACH UNIT) Z36CVCK Designer Clean View Circulating Kit (Must be used on both sides, order two) 348 MGSKBL Grill Kit See Through Black (Two Sets) 180 ACCESSORIES OPTIONAL MDV38RLE Refractory Liner End (Small Panel) 94 MDV38RLS Refractory Liner Side (Large Panel) 140 Z36FK Fan Kit w/variable Speed Wall Mount Control (Temperature Sensing) 309 SURROUNDS (FOR SEE THROUGH LOUVERED INSTALLATION ONLY) Z36SBL Surround Black 242 SAFETY SCREENS Z36CSS Safety Screen Barrier Large Glass (Replacement) 201 M31CSSS Safety Screen Barrier Small Glass (Replacement) 169

Page 25 THERMOSTATS AND REMOTE CONTROLS GTFRCN Remote Control Millivolt Thermostat/Modulating/Fan NG 537 GTFRCP Remote Control Millivolt Thermostat/Modulating/Fan LP 537 EGTRC Remote Control IPI Thermostat 310 EGTMRCN Remote Control IPI Thermostat/Modulating NG 421 EGTMRCP Remote Control IPI Thermostat/Modulating LP 421 EGTFRCN Remote Control IPI Thermostat/Modulating/Fan NG 567 EGTFRCP Remote Control IPI Thermostat/Modulating/Fan LP 567

Page 26 HORIZONTAL STARTER KITS 4/7" ZDVHSK Horizontal Round Termination Vent Starter Kit 3 FT Length $245 Termination, Wall Thimble, 36" Flex Pipe, Screws, Mill Pac ZDVHSKSQ Horizontal Square Termination Vent Starter Kit 3 FT Length 289 Termination, Wall Thimble, 36" Flex Pipe, Screws, Mill Pac ZDVHSK5 Horizontal Round Termination Vent Starter Kit 5 FT Length 304 Termination, Wall Thimble, 60" Flex Pipe, Screws, Mill Pac ZDVHSKSQ5 Horizontal Square Termination Vent Starter Kit 5 FT Length 350 Termination, Wall Thimble, 60" Flex Pipe, Screws, Mill Pac HORIZONTAL VENTING 4/7" FDVHT Horizontal Round Vent Termination 4/7 166 FDVHSQ Horizontal Square Vent Termination 4/7 206 FDVHSCU Safety Cage Universal for Horizontal Termination 107 FDVHSS Horizontal Stucco Shield 53 Z47ST24 Snorkel Termination 24" 616 Z47ST36 Snorkel Termination 36" 660 Z57STSC Safety Cage for Snorkel Termination 171 ZDVWT Wall Thimble (Horizontal Venting) 81 ZDVSS Siding Shield Heat Deflector for FDVHT Round Termination 24 ZDVSSLR Siding Shield Large Return for FDVHSQ or FDVHT 62 VERTICAL VENTING 4/7" FDVVT40 Vertical Vent Termination 4/7 180 Z47VT Vertical Vent Termination (Skyline II/III VRB46/ZRB46) 180 ZDVAIS Attic Insulation Shield 89 Z7AIS24 Attic Insulation Shield 24" 118 ZDVVOS Offset Support 37 ZDVFS Firestop Spacer 37 ZDVRS Roof Support 54 Z47GP36 Galvanized Pipe 4 and 7" x 36" (Vertical Installations) 202 Z47GP48 Galvanized Pipe 4 and 7" x 48" (Vertical Installations) 214 FLASHINGS VERTICAL VENTING 4/7" ZDVAAF Flashing 7" c/w Storm Collar (1/12 to7/12) 75 ZDVAF2 Flashing 7" c/w Storm Collar (8/12 to 12/12) 101 ZDVAF3 Flashing 7" c/w Storm Collar Flat 98 ZDV7SC Storm Collar 7 " 19 FLEX KITS 4/7", CLAMPS, CONNECTORS AND INSULATION SLEEVE ZDVFK5 Flex Kit (4" & 7" Dia.) x 5FT (c/w Springs, Screws, Mill Pac) 165 ZDVFK8 Flex Kit (4" & 7" Dia.) x 8FT (c/w Springs, Screws, Mill Pac) 233 ZDVFK20 Flex Kit (4" & 7" Dia.) x 20FT (c/w Springs, Screws, Mill Pac) 443 ZDV4FC Flex Connector 4" Diameter 17 ZDV7FC Flex Connector 7" Diameter 25 ZDV4FCL Flex Clamp 4" 13 ZDV7FCL Flex Clamp 7" 14 ZDV4SS Spring 4" Standoff Spacer 13 MDV38IS Insulation Sleeve 3ft for Low Enclosures 50 HARD PIPE ADAPTERS 4/6 5/8" ZDVDFA Dura Vent Fireplace Adapter (Sloped Flue) 151 (For ZDV3318/ZCV36/39/42/HBZDV36/42/47/MDV31)

Page 27 HORIZONTAL POWER VENT STARTER KIT 4/7" Approved for Models: ZDV3622, ZDVRB3622, HBZDV3624, HBZDV3628, HBZDV3632 HBZDV4224, HBZDV4228, HBZDV4232, VRB46, HBZDV4736, ZCV39, ZCV42, ZCV3622, ZCVRB3622 and MDV31 series. STEP 1) CHOOSE HORIZONTAL POWER VENT TERMINATION HORIZONTAL POWER VENT STARTER KIT PVH58 Horizontal Power Vent Starter Kit Termination, Wall Thimble $1,095 20 Ft Wiring Harness, Mill Pac Note: Must use a one foot section of 5/8 DV hard pipe to connect to the Power Vent Termination (not supplied) STEP 2) CHOOSE CONTROL MODULE OR HARNESS DEPENDENT ON VALVE SYSTEM CHOOSE POWER VENT CONTROL MODULE OR HARNESS BY SYSTEM TYPE: PVC58MV Power Vent Control Module for Millivolt Models 851 PVC58IPI Power Vent Control Module for Proflame 1 IPI Models 851 584 X12 Harness for Proflame 2 IPI Deluxe Models 52 STEP 3) CHOOSE ADDITIONAL HARNESS EXTENSION (DISTANCE FROM POWER VENT TO APPLIANCE) CHOOSE APPROPRIATE LENGTH OF EXTENSION HARNESS: (Distance from the power vent to the appliance) PVH20H Harness Extension 20 FT 282 STEP 4) CHOOSE VENTING TO BE USED: SECTION 1 HARD PIPE, SECTION 2 FLEX VENT SECTION 1 DIRECT VENT HARD PIPE for entire installation (Two Adapters needed one at Flue and one at Termination) Flue of Fireplace Choose appropriate adapter for fireplace ZDVDFA Duravent Fireplace Adapter (for Gemini, Skyline, Solara, Solace, Bentley) 151 ZDVDKA Duravent Stove Adapter (Skyline III VRB46 Power Vent Only) 86 Termination End ZDVDIA Duravent Hard Pipe Adapter (used to connect 4/6 5/8 to 5/8 Hard Pipe) 266 SECTION 2 FLEX VENT Used for entire installation order Z47PVA Note: Must use a one foot section of 5/8 DV hard pipe connected to the power vent on all installations. Termination End Z47PVA Flex Pipe Adapter Kit (to adapt flex pipe to power vent to hard pipe) 146 FLEX VENTING KITS: ZDVFK5 Flex Kit (4" & 7" Dia.) x 5' (c/w Springs, Screws, Mill Pac) 165 ZDVFK8 Flex Kit (4" & 7" Dia.) x 8' (c/w Springs, Screws, Mill Pac) 233 ZDVFK20 Flex Kit (4" & 7" Dia.) x 20' (c/w Springs, Screws, Mill Pac) 443 POWER VENT ACCESSORIES ZDV4FC Flex Connector 4" Diameter 17 ZDV7FC Flex Connector 7" Diameter 25 ZDV4FCL Flex Clamp 4" 13 ZDV7FCL Flex Clamp 7" 14 ZDV4SS Spring 4" Standoff Spacer 13 PVH58WT Wall Thimble for Power Vent 113

Page 28 MCVP42 MULTI SIDED CLEAN VIEW PENINSULA DIRECT VENT FIREPLACE: Listed for USA/Canada as a Vented Gas Fireplace ANSI Z21.50, RH Burner, SIT Nova Valve with Hi/Lo Adjustment, Wall Switch, Safety Screens, Tempered Glass 5/8" Sloped Flue MCVP42N Peninsula Fireplace, Millivolt (as above) Natural Gas, 30,500 BTU $4,126 MCVP42LP Peninsula Fireplace, Millivolt (as above) Propane, 28,500 BTU 4,195 MCVP42NE Peninsula Fireplace, IPI (as above) Natural Gas, 30,500 BTU 4,403 MCVP42LPE Peninsula Fireplace, IPI (as above) Propane, 28,500 BTU 4,473 42MP CKLP Conversion Kit Millivolt To Propane 76 42MP CKNG Conversion Kit Millivolt To Natural Gas 76 42MP CKLPI Conversion Kit IPI To Propane 90 42MP CKNGI Conversion Kit IPI To Natural Gas 90 CHOOSE LOG GRATE & LOG SET OR GLASS TRAY & MEDIA : (REQUIRED FOR EACH UNIT) M42LG Log Grate (need to choose log set) 154 M42LOG4 Log Set KINGSMAN Oak 8 Pieces 725 MP42GT Glass Tray for MCVP42 (Requires Glass Media) 154 (Maximum Amount of Glass: 5lbs for Burner, and 20lbs for Tray) M42LOG3 Log Set KINGSMAN Driftwood 6 Pieces 725 Z5GC Glass Media 1/2" Bronze 5 lbs 90 RBCB1 Cannonballs Assorted size and colors 319 ULK3 Universal Light Kit Two Lamps (for use with Glass Tray) 262 42MVB 258 Pilot Shield for Glass Tray and Log Grate (Replacement Part) 47 FIREPLACE ACCESSORIES OPTIONS: MP42CSSS Safety Screen Barrier Small (Replacement) 164 MP42CSSL Safety Screen Barrier Large (Replacement) 223 MP42RLT Refractory Fiber Brick Liner Traditional 164 MP42PL Porcelain Reflective Panel Liner 194 DECORATE THE BOTTOM OF YOUR FIREPLACE WITH LOG BITS: VLBIT4 Log Bits Large Four Piece Kit 111 VLBIT6 Log Bits Small Six Piece Kit 104

Page 29 THERMOSTATS AND REMOTE CONTROLS GTFRCN Remote Control Millivolt Thermostat/Modulating/Fan NG 537 GTFRCP Remote Control Millivolt Thermostat/Modulating/Fan LP 537 EGTRC Remote Control IPI Thermostat 310 EGTMRCN Remote Control IPI Thermostat/Modulating NG 421 EGTMRCP Remote Control IPI Thermostat/Modulating LP 421 EGTFRCN Remote Control IPI Thermostat/Modulating/Fan NG 567 EGTFRCP Remote Control IPI Thermostat/Modulating/Fan LP 567

Page 30 MCVP42 MULTI SIDED CLEAN VIEW PENINSUAL DIRECT VENT FIREPLACE: Listed for USA/Canada as a Vented Gas Fireplace Heater ANSI Z21.88, RH Burner, SIT Nova Valve with Hi/Lo Adjustment, Wall Switch, Safety Screens, Ceramic Glass 5/8" Sloped Flue MCVP42NH Peninsula Fireplace, Millivolt (as above) Natural Gas, 31,250 BTU $6,064 MCVP42LPH Peninsula Fireplace, Millivolt (as above) Propane, 29,000 6,133 MCVP42NHE Peninsula Fireplace, IPI (as above) Natural Gas, 31,250 BTU 6,341 MCVP42LPHE Peninsula Fireplace, IPI (as above) Propane, 29,000 6,410 42MP CKLPH Conversion Kit Millivolt To Propane 76 42MP CKNGH Conversion Kit Millivolt To Natural Gas 76 42MP CKLPHI Conversion Kit IPI To Propane 90 42MP CKNGHI Conversion Kit IPI To Natural Gas 90 CHOOSE LOG GRATE & LOG SET OR GLASS TRAY & MEDIA : (REQUIRED FOR EACH UNIT) M42LG Log Grate (need to choose log set) 154 M42LOG4 Log Set KINGSMAN Oak 8 Pieces 725 MP42GT Glass Tray for MCVP42 (Requires Glass Media) 154 (Maximum Amount of Glass: 5lbs for Burner, and 20lbs for Tray) M42LOG3 Log Set KINGSMAN Driftwood 6 Pieces 725 ZG5C Glass Media 1/2" Bronze 5 lbs 90 RBCB1 Cannonballs Assorted size and colors 319 ULK3 Universal Light Kit Two Lamps (for use with Glass Tray) 262 42MVB 258 Pilot Shield for Glass Tray and Log Grate (Replacement Part) 47 FIREPLACE ACCESSORIES OPTIONS: MP42CSSS Safety Screen Barrier Small (Replacement) 164 MP42CSSL Safety Screen Barrier Large (Replacement) 223 MP42RLT Refractory Fiber Brick Liner Traditional 164 MP42PL Porcelain Reflective Panel Liner 194 DECORATE THE BOTTOM OF YOUR FIREPLACE WITH LOG BITS: VLBIT4 Log Bits Large Four Piece Kit 111 VLBIT6 Log Bits Small Six Piece Kit 104

Page 31 THERMOSTATS AND REMOTE CONTROLS GTFRCN Remote Control Millivolt Thermostat/Modulating/Fan NG 537 GTFRCP Remote Control Millivolt Thermostat/Modulating/Fan LP 537 EGTRC Remote Control IPI Thermostat 310 EGTMRCN Remote Control IPI Thermostat/Modulating NG 421 EGTMRCP Remote Control IPI Thermostat/Modulating LP 421 EGTFRCN Remote Control IPI Thermostat/Modulating/Fan NG 567 EGTFRCP Remote Control IPI Thermostat/Modulating/Fan LP 567

Page 32 MCVST42 MULTI SIDED CLEAN VIEW SEE THROUGH DIRECT VENT FIREPLACE: Listed for USA/Canada as a Vented Gas Fireplace ANSI Z21.50, RH Burner, SIT Nova Valve with Hi/Lo Adjustment, Wall Switch, Safety Screens, Tempered Glass 5/8" Sloped Flue MCVST42N See Through Fireplace, Millivolt (as above) Natural Gas, 30,500 BTU $4,041 MCVST42LP See Through Fireplace, Millivolt (as above) Propane, 29,000 BTU 4,115 MCVST42NE See Through Fireplace, IPI (as above) Natural Gas, 30,500 BTU 4,322 MCVST42LPE See Through Fireplace, IPI (as above) Propane, 29,000 BTU 4,410 42MST CKLP Conversion Kit Millivolt To Propane 76 42MST CKNG Conversion Kit Millivolt To Natural Gas 76 42MST CKLPI Conversion Kit IPI To Propane 90 42MST CKNGI Conversion Kit IPI To Natural Gas 90 CHOOSE LOG GRATE & LOG SET OR GLASS TRAY & MEDIA : (REQUIRED FOR EACH UNIT) M42LG Log Grate (need to choose log set) 154 M42LOG4 Log Set KINGSMAN Oak 8 Pieces 725 MST42GT Glass Tray for MCVST42 (Requires Glass Media) 154 (Maximum Amount of Glass: 5lbs for Burner, and 20lbs for Tray) M42LOG3 Log Set KINGSMAN Driftwood 6 Pieces 725 ZG5C Glass Media 1/2" Bronze 5 lbs 90 RBCB1 Cannonballs Assorted size and colors 319 ULK3 Universal Light Kit Two Lamps (for use with Glass Tray) 262 42MVB 258 Pilot Shield for Glass Tray and Log Grate (Replacement Part) 47 SURROUNDS, DESIGNER DOORS AND SAFETY SCREEN ZCV42S1BL Surround Hearth Mount 4" Wide (Covers 44 5/8" W x 38 1/8" H) 396 ZCV42S1PFBL Surround Picture Frame 4" Wide (Covers 44 5/8" W x 40 1/8" H) 396 ZCV42S2PFBL Surround Picture Frame 1 5/8" Wide (Covers 40 1/8" W x 35 5/8" H) 349 FIREPLACE ACCESSORIES OPTIONS: ZCV42CSS Safety Screen Barrier Outside Fit (Replacement) 304 ZCV42CSS2 Safety Screen Barrier Inside Fit (Replacement) 304 ZCV TLK Tile Lip Kit (for Finishing Materials tile, brick) 59 MST42RLT Refractory Fiber Brick Liner (2 PCE) Traditional 319 MST42PL Porcelain Reflective Panel Liner (2 PCE) 392 Z46FK Fan Kit w/variable Speed Wall Mount Control (Temperature Sensing) 309 DECORATE THE BOTTOM OF YOUR FIREPLACE WITH LOG BITS: VLBIT4 Log Bits Large Four Piece Kit 111 VLBIT6 Log Bits Small Six Piece Kit 104

Page 33 THERMOSTATS AND REMOTE CONTROLS GTFRCN Remote Control Millivolt Thermostat/Modulating/Fan NG 537 GTFRCP Remote Control Millivolt Thermostat/Modulating/Fan LP 537 EGTRC Remote Control IPI Thermostat 310 EGTMRCN Remote Control IPI Thermostat/Modulating NG 421 EGTMRCP Remote Control IPI Thermostat/Modulating LP 421 EGTFRCN Remote Control IPI Thermostat/Modulating/Fan NG 567 EGTFRCP Remote Control IPI Thermostat/Modulating/Fan LP 567

Page 34 MCVST42 MULTI SIDED CLEAN VIEW SEE THROUGH DIRECT VENT FIREPLACE: Listed for USA/Canada as a Vented Gas Fireplace Heater ANSI Z21.88, RH Burner, SIT Nova Valve with Hi/Lo Adjustment, Wall Switch, Safety Screens, Ceramic Glass 5/8" Sloped Flue MCVST42NH See Through Fireplace, Millivolt (as above) Natural Gas, 31,000 BTU $6,008 MCVST42LPH See Through Fireplace, Millivolt (as above) Propane, 29,250 BTU 6,076 MCVST42NHE See Through Fireplace, IPI (as above) Natural Gas, 31,000 BTU 6,284 MCVST42LPHE See Through Fireplace, IPI (as above) Propane, 29,250 BTU 6,353 42MST CKLPH Conversion Kit Millivolt To Propane 76 42MST CKNGH Conversion Kit Millivolt To Natural Gas 76 42MST CKLPHI Conversion Kit IPI To Propane 90 42MST CKNGHI Conversion Kit IPI To Natural Gas 90 CHOOSE LOG GRATE & LOG SET OR GLASS TRAY & MEDIA : (REQUIRED FOR EACH UNIT) M42LG Log Grate (need to choose log set) 154 M42LOG4 Log Set KINGSMAN Oak 8 Pieces 725 MST42GT Glass Tray for MCVST42 (Requires Glass Media) 154 (Maximum Amount of Glass: 5lbs for Burner, and 20lbs for Tray) M42LOG3 Log Set KINGSMAN Driftwood 6 Pieces 725 ZG5C Glass Media 1/2" Bronze 5 lbs 90 RBCB1 Cannonballs Assorted size and colors 319 ULK3 Universal Light Kit Two Lamps (for use with Glass Tray) 262 42MVB 258 Pilot Shield for Glass Tray and Log Grate (Replacement Part) 47 SURROUNDS, DESIGNER DOORS AND SAFETY SCREEN ZCV42S1BL Surround Hearth Mount 4" Wide (Covers 44 5/8" W x 38 1/8" H) 396 ZCV42S1PFBL Surround Picture Frame 4" Wide (Covers 44 5/8" W x 40 1/8" H) 396 ZCV42S2PFBL Surround Picture Frame 1 5/8" Wide (Covers 40 1/8" W x 35 5/8" H) 349 FIREPLACE ACCESSORIES OPTIONS: ZCV42CSS Safety Screen Barrier Outside Fit (Replacement) 304 ZCV42CSS2 Safety Screen Barrier Inside Fit (Replacement) 304 ZCV TLK Tile Lip Kit (for Finishing Materials tile, brick) 59 MST42RLT Refractory Fiber Brick Liner (2 PCE) Traditional 319 MST42PL Porcelain Reflective Panel Liner (2 PCE) 392 Z46FK Fan Kit w/variable Speed Wall Mount Control (Temperature Sensing) 309 DECORATE THE BOTTOM OF YOUR FIREPLACE WITH LOG BITS: VLBIT4 Log Bits Large Four Piece Kit 111 VLBIT6 Log Bits Small Six Piece Kit 104

Page 35 THERMOSTATS AND REMOTE CONTROLS GTFRCN Remote Control Millivolt Thermostat/Modulating/Fan NG 537 GTFRCP Remote Control Millivolt Thermostat/Modulating/Fan LP 537 EGTRC Remote Control IPI Thermostat 310 EGTMRCN Remote Control IPI Thermostat/Modulating NG 421 EGTMRCP Remote Control IPI Thermostat/Modulating LP 421 EGTFRCN Remote Control IPI Thermostat/Modulating/Fan NG 567 EGTFRCP Remote Control IPI Thermostat/Modulating/Fan LP 567

Page 36 HORIZONTAL STARTER KIT 5/8" MCVP42/MCVST42 Z58HSK5 Horizontal Vent Starter Kit 5/8" X 5 FT Flex, Termination, Wall Thimble $349 Wall Thimble Shield, Screws, and Mill Pac HORIZONTAL VENTING 5/8" Z58HT Horizontal Round Vent Termination 5/8 184 Z58WTS Horizontal Wall Thimble Shield (For Low Enclosures) 38 FDVHSCU Horizontal Safety Cage 107 Z58WT Horizontal Wall Thimble 81 Z58SS Siding Shield Heat Deflector for Horizontal Round Termination 24 Z58SSLR Siding Shield Large Return for Square or Round Terminations 62 VERTICAL VENTING 5/8" Z58VT Vertical Vent Termination 5/8 203 Z58AIS24 Attic Insulation Shield 24" 124 ZDVVOS Offset Support 37 Z58FS Firestop Spacer 45 Z58RS Roof Support 69 Z58GP36 Galvanized Pipe 5 and 8" Dia. x 36" (Vertical Installations) 240 FLASHINGS VERTICAL VENTING 5/8" Z58AAF Flashing 8" c/w Storm Collar (1/12 to7/12) 75 Z58AF2 Flashing 8" c/w Storm Collar (8/12 to 12/12) 101 Z58AF3 Flashing 8" c/w Storm Collar Flat 98 ZDV8SC Storm Collar 8 " 19 FLEX KITS 5/8", CLAMPS AND CONNECTORS Z58FK5 Flex Kit (5" & 8" Dia.) x 5' Expanded (c/w Springs, Screws, Mill Pac) 178 Z58FK8 Flex Kit (5" & 8" Dia.) x 8' Expanded (c/w Springs, Screws, Mill Pac) 251 Z58FK20 Flex Kit (5" & 8" Dia.) x 20' Expanded (c/w Springs, Screws, Mill Pac) 484 ZDV5FC Flex Connector 5" Diameter 21 ZDV8FC Flex Connector 8" Diameter 29 ZDV5FCL Flex Clamp 5" 14 ZDV8FCL Flex Clamp 8" 16 ZDV4SS Spring Standoff Spacer for Inner Pipe 13 Hard Pipe Adapter 5/8" Z58DFA Hard Pipe Adapter 5/8" (MCVP42, MCVST42) 213

Page 37 HORIZONTAL POWER VENTING 5/8" Approved for MCVP42, MCVST42 STEP 1) CHOOSE HORIZONTAL POWER VENT TERMINATION HORIZONTAL POWER VENT STARTER KIT 5/8" PVH58 Horizontal Power Vent Starter Kit Termination, Wall Thimble $1,095 20 Ft Wiring Harness, Mill Pac Note: Must use a one foot section of 5/8 DV hard pipe to connect to the Power Vent Termination (not supplied) STEP 2) CHOOSE CONTROL MODULE OR HARNESS DEPENDENT ON VALVE SYSTEM POWER VENT CONTROL MODULE OR HARNES BY SYSTEM TYPE: PVC58MV Power Vent Control Module for Millivolt models 851 PVC58IPI Power Vent Control Module for Proflame 1 IPI models 851 584 X12 Harness for Proflame 2 IPI Deluxe Models 52 STEP 3) CHOOSE ADDITIONAL HARNESS EXTENSION (DISTANCE FROM POWER VENT TO APPLIANCE) POWER VENT EXTENSION HARNESS: (Measure distance from the power vent to the appliance) PVH20H Harness Extension 20 FT 282 STEP 4) CHOOSE VENTING TO BE USED: SECTION 1 HARD PIPE, SECTION 2 FLEX VENT SECTION 1 DIRECT VENT HARD PIPE Used for entire installation Order Z58DFA Z58DFA DuraVent Hard Pipe Adapter 5/8" MCVST42/MCVP42 213 SECTION 2 FLEX VENT Used for entire installation Order Z58PVA Note: Must use a one foot section of 5/8 DV hard pipe to connect to the Power Vent Termination (not supplied) Z58PVA Flex Pipe Adapter Kit (to adapt flex pipe to power vent to hard pipe) 53 FLEX VENTING KITS: Z58FK5 Flex Kit (5" & 8" Dia.) x 5' Expanded (c/w Springs, Screws, Mill Pac) 178 Z58FK8 Flex Kit (5" & 8" Dia.) x 8' Expanded (c/w Springs, Screws, Mill Pac) 251 Z58FK20 Flex Kit (5" & 8" Dia.) x 20' Expanded (c/w Springs, Screws, Mill Pac) 484 OPTIONAL POWER VENT ACCESSORIES ZDV5FC Flex Connector 5" Diameter 21 ZDV8FC Flex Connector 8" Diameter 29 ZDV5FCL Flex Clamp 5" 14 ZDV8FCL Flex Clamp 8" 16 ZDV4SS Spring Standoff Spacer for Inner Pipe 13 PVH58WT Wall Thimble for Power Vent 113

Page 38 ZV3600 ZERO CLEARANCE B VENTED GAS FIREPLACES 36" WIDE SERIES Listed for USA/Canada as a Vented Gas Fireplace, with a Dual Burner, SIT Valve with Hi/Lo, Downdraft Limit Switch, Wall Switch, Tempered Glass, Safety Screen, 4" Top Flue, Framing 36 3/8 W x 34 H x 15 3/8"D ZV3600N B Vent Fireplace, Millivolt Valve (as above) Natural Gas, 21,000 BTU $1,392 ZV3600LP B Vent Fireplace, Millivolt Valve (as above) Propane, 20,000 BTU 1,428 ZV3600NE B Vent Fireplace, IPI Valve (as above) Natural Gas, 21,000 BTU 1,668 ZV3600LPE B Vent Fireplace, IPI Valve (as above) Propane, 20,000 BTU 1,706 3600ZV CKLP Conversion Kit Millivolt To Propane 76 3600ZV CKNG Conversion Kit Millivolt To Natural Gas 76 3600ZV CKLPI Conversion Kit IPI To Propane 90 3600ZV CKNGI Conversion Kit IPI To Natural Gas 90 LOG SET: (REQUIRED FOR EACH UNIT) LOGC42 Log Set Four Piece Classic Oak (ZDV3320, 3624/28, 4224/28 Series) 142 LOGC43 Log Set Four Piece Traditional Oak (ZDV3320, 3624/28, 4224/28 Series) 171 LOGC44 Log Set Eight Piece Burnt Oak (ZDV3320, 3624/28, 4224/28 Series) 171 GRILL KIT: (Required for each unit) Z1GBL Grill Kit Black 94 FIREPLACE ACCESSORIES OPTIONS: Z33FK Fan Kit w/variable Speed Wall Mount Control (Temperature Sensing) 309 Z36RL Refractory Liner (3 Piece) 163 Z65FAK Fresh Air Kit 44 Z36CSS Safety Screen Barrier (Replacement) 201 SURROUNDS (For Louvered Units only) (Coverage 34 1/2" H x 41 1/8" W) Z36SBL Surround Black 242 DECORATE THE BOTTOM OF YOUR FIREPLACES VLBIT4 Log Bits Large Four Piece Kit 111 VLBIT6 Log Bits Small Six Piece Kit 104

Page 39 THERMOSTATS AND REMOTE CONTROLS GTFRCN Remote Control Millivolt Thermostat/Modulating/Fan NG 537 GTFRCP Remote Control Millivolt Thermostat/Modulating/Fan LP 537 EGTRC Remote Control IPI Thermostat 310 EGTMRCN Remote Control IPI Thermostat/Modulating NG 421 EGTMRCP Remote Control IPI Thermostat/Modulating LP 421 EGTFRCN Remote Control IPI Thermostat/Modulating/Fan NG 567 EGTFRCP Remote Control IPI Thermostat/Modulating/Fan LP 567

Page 40 IDV26 DIRECT VENT FIREPLACE INSERT Listed for USA/Canada as a Vented Gas Fireplace, Includes Dual Burner with Glowing Embers, Ceramic Glass, Variable Speed with Thermostat Controlled Blower, Safety Screen, Two Three Inch Flues, 30,000 BTU/HR (Minimum Size of Fireplace for installation 28/33" W x 19 1/2" H x 14 1/8"D) IDV26N Insert Direct Vent, Millivolt Valve (as above) Natural Gas $2,255 IDV26LP Insert Direct Vent, Millivolt Valve (as above) Propane 2,315 IDV26NE Insert Direct Vent ( as above) IPI Natural Gas 2,534 IDV26LPE Insert Direct Vent ( as above) IPI Propane 2,594 26IDV CKLP Conversion Kit Millivolt To Propane 76 26IDV CKNG Conversion Kit Millivolt To Natural Gas 76 LOG SET OR GLASS SUPPORT PLATFORM: (REQUIRED FOR EACH UNIT) LOGF27 Log Set Fiber Split Oak (IDV26) 387 RSP10 Glass Support Platform with Bronze Decorative Glass IDV26/33/36 487 36IDV 204 Pilot Shield for RSP10 (Replacement Part) 47 CHOOSE CLEAN VIEW FRONT (REQUIRED FOR EACH UNIT) AND SURROUND IF NEEDED Clean View Front Slim Measures 35 5/8"W x 22 3/4"H (Components In for Minimum Fireplace Opening of 31" W) I26CV1BL Clean View Front Slim Black 1 3/4" Depth 251 I26CV3BL Clean View Front Slim Black 3 1/2" Depth 292 I26S1BL Surround Slim Black (Covers 42" W x 27 1/2"H) $167 I26SUBL Surround Universal Black 239 (Three Sided 47 1/2"W x 28 5/8" H, Picture Frame Size 47 1/2" W x 35 5/8"H) Clean View Front Series 1 Picture Frame 35 5/8" W x 25 7/8"H) I26CVPF1BL Clean View Front Slim Picture Frame Black 333 I26SPF1BL Surround Picture Frame Slim Black (Covers 39 3/8"W x 29 3/4" H) 226 I26SUBL Surround Universal Black 239 (Picture Frame Size 47 1/2" W x 35 5/8"H, Three Sided 47 1/2"W x 28 5/8" H) Clean View Front Series 2 Wide Measures 44 5/8"W x 26 5/8"H (Components Out for Minimum Fireplace Opening of 28" W) I26CV2BL Clean View Front Wide Black 286 I26CVPF2BL Clean View Front Wide Picture Frame Black (44 7/8" W x 33 1/2 "H) 380 I26SUBL Surround Universal Black 239 (Picture Frame Size 47 1/2" W x 35 5/8"H, Three Sided 47 1/2"W x 28 5/8" H)

Page 41 RISER FOR SURROUNDS RAISES COVERAGE HEIGHT BY 2 1/2" I33R40 Riser For Surround (2 1/2") For Use on I33S4028B 138 I33R44 Riser For Surround (2 1/2") For Use on I33S4430B 138 FIREPLACE ACCESSORY OPTIONS I26CSS Safety Screen Barrier (Replacement) 180 IDV26RL Refractory Brick Liner (3 PCE) 269 IDV26PRL Porcelain Reflective Panel Liner (3 PCE) 351 I33CS Mantel Clearance Shield 35 DECORATE THE BOTTOM OF YOUR FIREPLACE VLBIT4 Log Bits Large Four Piece Kit 111 VLBIT6 Log Bits Small Six Piece Kit 104 THERMOSTATS AND REMOTE CONTROLS EGTRC Remote Control IPI Thermostat 310 EGTMRCN Remote Control IPI Thermostat/Modulating NG 421 EGTMRCP Remote Control IPI Thermostat/Modulating LP 421 VENTING COMPONENTS IDVVT36 Vertical Vent Termination (3/3"), Mill Pac and Screws 175 IDVFK25 Flex Pipe Kit ( 2 x 3" Dia x 25FTGas Flex Liner) 384 IDVLCP Block Off Plate For Lower Chase (11 3/4" x 14 3/4") 34 ZDV3FC Flex Connector 3" Diameter 17 **MG Duravent (Order Kit #46DVA CL33)

Page 42 IDV33 DIRECT VENT FIREPLACE INSERT Listed for USA/Canada as a Vented Gas Fireplace, Includes Dual Burner with Glowing Embers, Ceramic Glass, Safety Screen, SIT Valve, Variable Speed Controlled Blower, Two Three Inch Flues, 31,000 BTU/HR NG, 28,500 BTU/HR LP, Minimum Fireplace Opening 26 3/8" W x 21 3/8" H x 14 3/8"D IDV33N Insert Direct Vent ( as above) CV Adaptable Millivolt Natural Gas $2,115 IDV33LP Insert Direct Vent ( as above) CV Adaptable Millivolt Propane 2,152 IDV33NE Insert Direct Vent ( as above) CV Adaptable IPI Natural Gas 2,394 IDV33LPE Insert Direct Vent ( as above) CV Adaptable IPI Propane 2,430 33IDV CKLP Conversion Kit Millivolt To Propane 76 33IDV CKNG Conversion Kit Millivolt To Natural Gas 76 33IDV CKLPI Conversion Kit IPI To Propane 90 33IDV CKNGI Conversion Kit IPI To Natural Gas 90 LOG SET OR GLASS SUPPORT: (REQUIRED FOR EACH UNIT) LOGF35 Log Set Fiber Split Oak (F350,F300,IDV33) 342 RSP10 Glass Support Platform with Bronze Decorative Glass IDV26/33/43 487 36IDV 204 Pilot Shield for RSP10 (Replacement Part) 47 CHOOSE LOUVER KIT OR CLEAN VIEW KIT AND APPROPRIATE SURROUND INSERT FITS FIREPLACE OPENING OF 26 3/8" W x 21 3/8" H x 14 3/8" DEEP I33LK Louver Kit with Pillars Black 251 VI30GBL Grill Kit Black (Required when using I33LK) 100 SURROUND KITS FOR USE WITH I33LK LOUVER KIT I33S3426B Surround Top Black (1Pce) (Covers 34 1/2" W x 26 5/8" H) 71 I33SR2BL Surround Clean View Black (Covers 39" W x 27" H) 164 I33S4028B Surround Black (3 Pce) (Covers 40" W x 28" H) 159 I33S4430B Surround Black (3 Pce) (Covers 44" W x 30" H) 175 I33USR4BL Surround Universal Black (Covers 45" W x 35" H) 175 INSERT FITS FIREPLACE OPENING OF 26 3/8" W x 21 3/8" H x 14 3/8" DEEP CLEAN VIEW I33CV/I33CV3 COVERAGE (33 3/8" W x 23" H) I33CVBL Clean View Kit Black 1 3/4" Depth 251 I33CVCV Clean View Kit Copper Vein 1 3/4" Depth 374 I33CVPW Clean View Kit Pewter 1 3/4" Depth 374 I33CV3BL Clean View Kit Black 3 1/2" Depth 299 SURROUND KITS FOR USE WITH I33CV/CV3 CLEAN VIEW KIT I33SR2BL Surround Clean View Black (Covers 39" W x 27" H) 164 I33SR2CV Surround Clean View Copper Vein 282 I33SR2PW Surround Clean View Pewter 282 I33USR4BL Surround Universal Black (Covers 45" W x 35" H) 175 I33SRP3BL Surround Picture Frame Black (Covers 41" W x 31" H) 213

Page 43 INSERT FITS FIREPLACE OPENING OF 26 3/8" W x 21 3/8" H x 14 3/8" DEEP CLEAN VIEW KIT I33CV5 SIZE (37 1/8" W x 25 1/4" H) When using a I33CV5 a Door Frame (I33SF1BL) is Required I33CV5BL Clean View Kit Black 2 1/4" Depth $449 I33SF1BL Door Frame c/w Safety Screen 342 A BACK TRIM SURROUND WILL BE REQUIRED IF THE FIREPLACE OPENING IS SMALLER THAN 29 3/8" W x 22 3/8" H X 16 1/8" D I33BT1BL Back Trim Surround Black (Covers 39" W x 26" H) 214 THE UNIVERSAL SURROUND MAY BE USED WITH BACK TRIM SURROUND I33USR4BL Surround Universal Black (Covers 45" W x 34" H) 175 When using a I33CVPF5 CV Picture Frame a Door Frame (I33SF1BL) is Required I33CVPF5BL Clean View Picture Frame Black (37 1/8" W x 25 1/4" H) 481 I33SF1BL Door Frame c/w Safety Screen 342 I33BTPFBL Back Trim Surround For Picture Frame Clean View (41" W x 31"H) 230 A BACK TRIM SURROUND WILL BE REQUIRED IF THE FIREPLACE OPENING IS SMALLER THAN 29 3/8" W x 22 3/8" H X 16 1/8" D INSERT FITS A FIREPLACE OPENING OF 29 3/8" W x 22 3/8" H x 16 1/8" DEEP CLEAN VIEW KIT I33CV5 SIZE (37 1/8" W x 25 1/4" H) When using a I33CV5 or I33CVPF5 a Designer Door or Door Frame is Required I33CV5BL Clean View Kit Black 2 1/4" Depth 449 I33SF1BL Door Frame c/w Safety Screen 342 SURROUND KITS FOR USE WITH I33CV5 I33SR2BL Surround Clean View Black (Covers 39" W x 27" H) 164 I33USR4BL Surround Universal Black (Covers 45" W x 35" H) 175 I33CVPF5BL Clean View Picture Frame Black (37 1/8" W x 25 1/4" H) 481 I33SF1BL Door Frame c/w Safety Screen 342 I33SRP3BL Surround Picture Frame Black (Covers 41" W x 31" H) 213 FIREPLACE ACCESSORIES Riser for Surrounds Raises Coverage Height by 2 1/2" I33R40 Riser For Surround (2 1/2") x 40" W 138 I33R44 Riser For Surround (2 1/2") x 44" W 138 Z33CSS Safety Screen Barrier (Replacement) 169 IDV33RL Refractory Brick Liner (3 PCE) 158 IDV33PRL Porcelain Reflective Panel Liner (3 PCE) 411 I33CS Mantel Clearance Shield 35

Page 44 THERMOSTATS AND REMOTE CONTOLS EGTRC Remote Control IPI Thermostat 310 EGTMRCN Remote Control IPI Thermostat/Modulating NG 421 EGTMRCP Remote Control IPI Thermostat/Modulating LP 421 VENTING COMPONENTS IDVVT36 Vertical Vent Termination (3/3"), Mill Pac and Screws 175 IDVFK25 Flex Pipe Kit ( 2 x 3" Dia x 25FTGas Flex Liner) 384 IDVLCP Block Off Plate For Lower Chase (11 3/4" x 14 3/4") 34 ZDV3FC Flex Connector 3" Diameter 17 **MG Duravent (Order Kit #46DVA CL33)

Page 45 IDV43 DIRECT VENT FIREPLACE INSERT Listed for USA/Canada as a Vented Gas Fireplace, Includes Dual Burner with Glowing Embers, Ceramic Glass, SIT Valve, Variable Speed Blower, 3" Air Intake 4" Exhaust, 34,250 BTU NG, 30,000 BTU LP Minimum Fireplace Opening: Non Recessed Size: 30 3/4" W x 25 5/8" H x 14 3/4"D IDV43N Insert Direct Vent ( as above) CV Adaptable Millivolt Natural Gas $2,394 IDV43LP Insert Direct Vent ( as above) CV Adaptable Millivolt Propane 2,444 IDV43NE Insert Direct Vent ( as above) CV Adaptable IPI Natural Gas 2,674 IDV43LPE Insert Direct Vent ( as above) CV Adaptable IPI Propane 2,725 36IDV CKLP Conversion Kit Millivolt To Propane 76 36IDV CKNG Conversion Kit Millivolt To Natural Gas 76 36IDV CKLPI Conversion Kit IPI To Propane 90 36IDV CKNGI Conversion Kit IPI To Natural Gas 90 LOG SET OR ROCK SUPPORT OR GLASS SUPPORT PLATFORM: (REQUIRED FOR EACH UNIT) LOGF36 Log Set Fiber Split Oak 457 RSP10 Glass Support Platform with Bronze Decorative Glass IDV26/33/43 487 36IDV 204 Pilot Shield for RSP10 (Replacement Part) 47 CHOOSE LOUVER KIT OR CLEAN VIEW KIT AND APPROPRIATE SURROUND INSERT FITS FIREPLACE OPENING OF 30 3/4" W x 25 5/8" H x 14 3/4" DEEP I43LK Louver Kit with Pillars (Includes Black Grills and Safety Barrier) 527 (Covers 39" W x 28 3/4"H) SURROUND KITS FOR USE WITH I43LK LOUVER KIT I43LKS1BL Surround Top Black (1Pce) (Covers 39" W x 31 3/4" H x 1/16" D) 91 I43LKS2BL Surround Black (3 Pce) (Covers 44" W x 32 3/8" H x 1/16"D) 206 I43US4736BL Surround Universal Black (1 Pce) (Covers 47" W x 36" H x 1/16"D) 206 INSERT FITS FIREPLACE OPENING OF 30 3/4" W x 25 5/8" H x 14 3/4" DEEP CLEAN VIEW KIT SERIES 1 and 3 SIZE (37 1/2" W x 27 1/4" H) I43CV1BL Clean View Kit Black 1 3/4" Depth (Includes Safety Barrier) 429 I43CV1CV Clean View Kit Copper Vein 1 3/4" Depth (Includes Safety Barrier) 565 I43CV1PW Clean View Kit Pewter 1 3/4" Depth (Includes Safety Barrier) 565 I43CV3BL Clean View Kit Black 3 1/2" Depth (Includes Safety Barrier) 473 SURROUND KITS FOR USE WITH I43CV1/CV3 CLEAN VIEW KIT I43SPF1BL Surround Picture Frame Black (Covers 43 1/2" W x 33 3/8" H x 1/2"D) 251 I43S4432BL Surround Clean View Black (Covers 44" W x 32" H x 1/2"D) 201 I43S4432CV Surround Clean View Copper Vein 325 I43S4432PW Surround Clean View Pewter 325 I43US4736BL Surround Universal Black (1 Pce) (Covers 47" W x 36" H x 1/16"D) 206

Page 46 INSERT FITS FIREPLACE OPENING OF 30 3/4" W x 25 5/8" H x 14 3/4" DEEP CLEAN VIEW KIT I43CV5 SIZE (41 3/16" W x 29 1/16" H) When using a I43CV5, a Door Frame and Back Trim Surround is Required I43CV5BL Clean View Kit Black 2 1/4" Depth $473 I43SF1BL Door Frame c/w Safety Screen 352 SURROUND KITS FOR USE WITH I43CV5 (When Installed in a fireplace opening smaller than 33 1/2"W x 26 5/8"H x 16 5/8" D a Back Trim Surround is Required, a Universal Surround may be needed also.) I43BT4230BL Back Trim Surround Black (Covers 42" W x 30" H x 1 1/4" D) 225 I43BT4432BL Back Trim Surround Black (Covers 44" W x 32" H x 1 1/4" D) 230 I43US4736BL Surround Universal Black (1 Pce) (Covers 47" W x 36" H x 1/16"D) 206 INSERT FITS IN A FIREPLACE OPENING OF 33 1/2" W x 26 5/8" H x 16 5/8" DEEP CLEAN VIEW KIT I43CV5 SIZE (41 3/16" W x 29 1/16" H) When using a I43CV5, a Door Frame is Required I43CV5BL Clean View Kit Black 2 1/4" Depth 473 I43SF1BL Door Frame c/w Safety Screen 352 SURROUND KITS FOR USE WITH I43CV5 FLUSH LOOK I43S4432BL Surround Clean View Black (Covers 44" W x 32" H x 1/2"D) 201 I43S4432CV Surround Clean View Copper Vein 325 I43S4432PW Surround Clean View Pewter 325 I43US4736BL Surround Universal Black (1 Pce) (Covers 47" W x 36" H x 1/16"D) 206 FIREPLACE ACCESSORIES (Riser for Surrounds Raises Coverage Height by 2 1/2") I33R44 Riser For Surround (2 1/2") x 44" W 138 IDV36RLT Refractory Fiber Brick Liner (3 PCE) Traditional 201 IDV36RLH Refractory Fiber Brick Liner (3 PCE) Herringbone 201 IDV36PRL Porcelain Reflective Panel Liner (3 PCE) 528 I33CS Mantel Clearance Shield 35 HB36CSS Safety Screen Barrier (Replacement) 214 I43CSS Safety Screen Barrier (I43SF1BL/MQ43DD1BL) 241

Page 47 THERMOSTATS AND REMOTE CONTROLS EGTRC Remote Control IPI Thermostat 310 EGTMRCN Remote Control IPI Thermostat/Modulating NG 421 EGTMRCP Remote Control IPI Thermostat/Modulating LP 421 VENTING COMPONENTS IDVVT43 Vertical Vent Termination (4/3"), (Mill Pac and screws) 185 I43FK25 Flex Pipe Kit (3&4" Dia x 25FT Gas Flex Liner) 395 I43LCP Block Off Plate For Lower Chase (11 3/4" x 14 3/4") 34 ZDV3FC Flex Connector 3" Diameter 17 ZDV4FC Flex Connector 4" Diameter 17 **MG Duravent Venting (Order Kit #46DVA CL34)

Page 48 VFI25 VENTED GAS FIREPLACE INSERT Listed for USA/Canada as a Vented Gas Fireplace, Includes Dual Burner with Glowing Embers, Ceramic Glass, SIT Valve with Hi/Lo, Variable Speed with Thermostat Controlled Blower, Safety Spill Switch, Safety Screen, Four Inch Flue, 25,000 BTU (Minimum Size of Fireplace for installation 24"W x 17 1/2"H x 16"D) VFI25N Fireplace Insert, Millivolt Valve (as above) Natural Gas $2,136 VFI25LP Fireplace Insert, Millivolt Valve (as above) Propane 2,168 25VFI CKLP Conversion Kit Millivolt To Propane 76 25VFI CKNG Conversion Kit Millivolt To Natural Gas 76 LOG SET: (REQUIRED FOR EACH UNIT) LOGC5 Log Set Four Piece Cast Split Oak (ZDV6000, VFI30, VFI25) 142 LOGC6 Log Set Five Piece Cast Split Oak with Ember Chunks (6000, VFI25/30) 242 GRILL KIT (REQUIRED FOR EACH INSERT) VI20GBL Grill Kit Black 100 SURROUND KIT AND TRIM KIT THREE PIECE (REQUIRED FOR EACH INSERT) V25S2436B Surround Deluxe Black (Size 24 13/16 x 36 3/16"W) 214 V25T2436B Trim Kit Black 101 V25S2640B Surround Large Deluxe Black (Size 26 13/16"H x 40 3/16"W) 238 V25T2640B Trim Kit Black 101 V2R2436 Riser For Deluxe Surround (2 1/2") For Use on V25S2436B 94 V2R2640 Riser For Deluxe Surround (2 1/2") For Use on V30S2640B & V25S2640B 94 FIREPLACE ACCESSORY OPTIONS VI25CSS Safety Screen Barrier (Replacement) $159 DCHS Heat Shield Requiured for Millivolt Remote Receivers 17 VENTING ACCESSORIES: VI4SK25 Chimney Liner Starter Kit (4" Diameter x 25') 256 Kit Includes: Aluminum Liner 25 Ft, Chimney Flashing, Rain Cap ZDV4FP8 Flex Pipe 4" Diameter x 8 FT 81 ZDV4FP20 Flex Pipe 4" Diameter x 20 Ft 187 ZDV4FC Flex Connector 4" Diameter 17 ZDV4FCL Flex Clamp 4" 13

Page 49 OUTDOOR FIRE PITS: Listed for Canada and USA FP2085N Round 20" Diameter 65,000 BTU Natural Gas $401 FP2085LP Round 20" Diameter 65,000 BTU Propane c/w Reg and 5 FT Hose 483 FP20COV Cover for Round Fire Pit 104 FP20SSR Stainless Steel Ring 117 FP2785N Rectangular 27" x 20" 65,000 BTU Natural Gas c/w Cover 616 FP2785LP Rectangular 27" x 20" 65,000 BTU Propane c/w Cover (c/w Reg & 5FT Hose) 692 LOG SET OR MEDIA : (REQUIRED FOR EACH FIRE PIT) LOGC85 Log Set Four Piece Cast Oak 241 MLR1410 Media 1/4" Lava Rock 10 lbs (Modern Look, no logs required) 43 OUTDOOR FIRE BOWLS FOR THE FP2085 FIRE PIT (FIRE PIT NOT INCLUDED) Fire Bowl Includes (Key Way Valve and Connectors 1/4 Lava Rock 20 Lbs, Leg Extension, Filler Strip Ring and SS Flex Connector) 30" Diameter x 14"H FPB30TB Fire Bowl Concrete Textured Charcoal 2,258 FPB30SG Fire Bowl Concrete Smooth Grey 1,737 FIRE BOWL OPTIONS: FPB30COVB Cover for Fire Bowl Black 221 FPB30TRG Trim Ring Charcoal 337 30FPB KWK Key Way Valve Kit and Components (for Custom Enclosures) 174 MEDIA REQUIREMENTS OPTIONS: (When not using LOGC85 Log Set) One bag of 1/4" Lava Rock is required for the Fire Pit. If ordering a Fire Bowl the 1/4" media is included with the Fire Bowl.

Page 50 OFP42 ZERO CLEARANCE OUTDOOR FIREPLACE 42" WIDE: Listed for USA/Canada For Outdoor Use Only, SIT Nova TMV Valve with Hi/Lo Adjustment Wall Switch, Stainless Steel Screens, Framing 42 1/8" W x 38 1/4" H x 18 1/2" D OFP42N Outdoor Fireplace, Satin Coat Black, Millivolt (as above) Natural Gas, 55,000 BTU $1,911 OFP42NS Outdoor Fireplace, Stainless Steel, Millivolt (as above) Natural Gas, 55,000 BTU 2,951 42OFP CKLP Conversion Kit Propane 55,000 BTU 76 LOG SET: (REQUIRED FOR EACH UNIT) LOGF37 Log Set Split Oak (OFP42) 467 FIREPLACE ACCESSORIES OPTIONS: OFP42SS Surround Stainless Steel 734 OFP42WCSS Weather Cover Stainless Steel 560 OFP42WCBL Weather Cover Black 220 OFP42RLT Brick Liner Traditional 369 OFP42RLH Brick Liner Herringbone 369 OFP42SA Spark Assist (AA Battery not included) 65

Page 51 VENTED GAS LOG SETS: Listed for USA and Canada Minimum Fireplace Dimensions: FOR 18" LOGS FOR 24" LOGS FOR 30" LOGS (25" Front Width, 18" Back Width, 18" Height x 15" Depth) (29" Front Width, 21" Back Width, 18" Height x 15" Depth) (36" Front Width, 26" Back Width, 18" Height x 17" Depth) ASH BED BURNER VSB18N Vented Gas Log Burner Millivolt Valve 48,500 BTU/HR Natural Gas $902 VSB18LP Vented Gas Log Burner Millivolt Valve 47,000 BTU/HR Propane 902 VSB24N Vented Gas Log Burner Millivolt Valve 73,000 BTU/HR Natural Gas 933 VSB24LP Vented Gas Log Burner Millivolt Valve 86,000 BTU/HR Propane 933 GRATE BURNER: VGB18N Vented Gas Log Burner Millivolt Valve 48,500 BTU/HR Natural Gas 902 VGB18LP Vented Gas Log Burner Millivolt Valve 47,000 BTU/HR Propane 902 VGB24N Vented Gas Log Burner Millivolt Valve 73,000 BTU/HR Natural Gas 933 VGB24LP Vented Gas Log Burner Millivolt Valve 86,000 BTU/HR Propane 933 LOG SET: (REQUIRED FOR EACH BURNER) VLOG18 Log Set Split Oak 18" 307 VLOG24 Log Set Reversible Charred Split or Barked Oak 24" 359 VLOG30 Log Set Reversible Charred Split or Barked Oak 30" 441 DECORATE THE BOTTOM OF YOUR FIREPLACE VLBIT4 Log Bits Large Four Piece Kit 111 VLBIT6 Log Bits Small Six Piece Kit 104 OPTIONAL ACCESSORIES:

Page 52 VENTED/VENT FREE GAS LOG SETS: (Listed for USA and Canada) Minimum Fireplace Dimensions: FOR 18" LOGS (19" Front Width, 19" Back Width, 18 3/4" Height x 12 1/2" Depth) FOR 24" LOGS (29" Front Width, 22 1/2" Back Width, 18 3/4" Height x 12 1/2" Depth) FOR 30" LOGS (38" Front Width, 28" Back Width, 18 3/4" Height x 13 1/2" Depth) GLVF24MAN Vent Free Gas Log Burner Manual Valve 38,250 BTU/HR Natural Gas $509 GLVF24MAP Vent Free Gas Log Burner Manual Valve 38,000 BTU/HR Propane 509 GLVF24MVN Vent Free Gas Log Burner Millivolt Valve 38,250 BTU/HR Natural Gas 730 GLVF24MVP Vent Free Gas Log Burner Millivolt Valve 38,000 BTU/HR Propane 730 LOG SET: (REQUIRED FOR EACH BURNER) LOGF18 Log Set Fiber Split Oak 18" 290 LOGF24 Log Set Fiber Split Oak 24" 335 LOGF30 Log Set Fiber Split Oak 30" 472 VENTED/VENT FREE MULTI SIDED GAS LOG SETS: (Listed for USA and Canada) BURNER SYSTEM: (Choose Appropriate Burner System) GLMVF40MVN Multi Sided Vent Free Burner System 38,000 BTU Natural Gas 840 GLMVF40MVP Multi Sided Vent Free Burner System 30,500 BTU Propane 840 LOG SET: (Required for Burner System Above) LOGC31 Log Set Seven Piece Cast Split Oak (for GLMVF40 or MDV31) 391 ACCESSORIES FOR MILLIVOLT GAS LOG SETS OPTIONAL Decorate the Bottom of Your Fireplace with Log Bits: VLBIT4 Log Bits Large Four Piece Kit 111 VLBIT6 Log Bits Small Six Piece Kit 104 VENT FREE HOODS FOR USA ONLY VFAHBL Adjustable Vent Free Hood Black 104 VFAHAB Adjustable Vent Free Hood Antique Brass 104 VFAHCR Adjustable Vent Free Hood Brushed Chrome 104 VFAHPB Adjustable Vent Free Hood Polish Brass 104

Page 53 ZVF24 Zero Clearance Vent Free Firebox 24" W with Pull Screens 580 Listed for USA, Framing 24 3/8" W x 30" H x 12 3/4" D BURNER SYSTEM (REQUIRED FOR ZVF24 FIREBOX) ZVFB2410MVN Vent Free Burner System Millivolt Valve 10,000 BTU/HR Natural Gas 611 ZVFB2410MVP Vent Free Burner System Millivolt Valve 10,000 BTU/HR Propane 611 (The ZVFB2410 Burner System is Bedroom Approved, unless stated otherwise.) ZVFB2426MVN Vent Free Burner System Millivolt Valve 26,000 BTU/HR Natural Gas 611 ZVFB2426MVP Vent Free Burner System Millivolt Valve 26,000 BTU/HR Propane 611 LOG SET: (REQUIRED FOR EACH UNIT) LOGF10 Log Set Fiber Split Oak 231 FIREPLACE SURROUNDS ZVF24SDBL Surround Deluxe Black Coverage (29"H x 25 1/2" W) 242 ZVF24SDCV Surround Deluxe Copper Vein Coverage (29"H x 25 1/2" W) 271 ZVF24SDPW Surround Deluxe Pewter Coverage (29"H x 25 1/2" W) 271 ZVF24SDSV Surround Deluxe Silver Vein Coverage (29"H x 25 1/2" W) 271 OVERLAY AND DESIGNER DOORS ZVF24ADDX Arch Door Frame Deluxe Black (352) 162 ZVF24ADDD Arch Door Frame Double Door Arch Black (355) 162 ZVF24DDA1BL Designer Door Arch Series 1 Black 531 FIREPLACE ACCESSORIES ZVF24RLH Refractory Fiber Brick Liner (3 PCE) Herringbone 214 ZVF24RLT Refractory Fiber Brick Liner (3 PCE) Traditional 214 Z33FK Fan Kit w/variable Wall Mount Speed Control (Temperature Sensing) 309

Page 54 ZVF33P ZERO CLEARANCE VENT FREE FIREBOX 33" WIDE 584 Listed for USA, with Pull Screens, Framing 33 1/8" W x 31" H x 13 3/4" D BURNER SYSTEM (REQUIRED FOR ZVF33 FIREBOX) Burner Systems Controls are Hidden and Accessed Through Grill ZVFB3330MAN Vent Free Burner System Manual Valve 30,000 BTU/HR Natural Gas 468 ZVFB3330MAP Vent Free Burner System Manual Valve 30,000 BTU/HR Propane 468 ZVFB3330MVN Vent Free Burner System Millivolt Valve 30,000 BTU/HR Natural Gas 613 ZVFB3330MVP Vent Free Burner System Millivolt Valve 30,000 BTU/HR Propane 613 LOG SET: (REQUIRED FOR EACH UNIT) LOGF18 Log Set Fiber Split Oak 18" 290 LOGF24 Log Set Fiber Split Oak 24" 335 GRILL Kit: (Required for each unit) VI30GBL Grill Kit Black 100 FIREPLACE ACCESSORY OPTIONS: SURROUNDS (Coverage 31 3/16"H x 36 5/8"W) Z6SBL Surround Black 242 FIREPLACE ACCESSORY OPTIONS: ZVF33DS Door Frame c/w Fixed Screen 224 Z33FK Fan Kit w/variable Wall Mount Speed Control (Temperature Sensing) 309 DECORATE THE BOTTOM OF YOUR FIREPLACE VLBIT4 Log Bits Large Four Piece Kit 111 VLBIT6 Log Bits Small Six Piece Kit 104 GTFRCN Remote Control Millivolt Thermostat/Modulating/Fan NG 537 GTFRCP Remote Control Millivolt Thermostat/Modulating/Fan LP 537

Page 55 MVF40 ZERO CLEARANCE UNIVERSAL MULTI SIDED VENT FREE FIREPLACE 995 Listed for USA as a Universal Firebox c/w Universal Bottom CHOOSE APPROPRIATE BURNER (REQUIRED FOR MVF40) Burner with Grate (Controls are Located in Firebox) Uses LOGC31 GLMVF40MVN Multi Sided Vent Free Burner System 38,000 BTU Natural Gas 840 GLMVF40MVP Multi Sided Vent Free Burner System 30,500 BTU Propane 840 LOG SET: (REQUIRED FOR EACH UNIT) Choose Appropriate Log Set LOGC31 Log Set Seven Piece Cast Split Oak (for GLMVF40 or MDV31) 391 Choose Your View and Grill Kit: (Required for each unit) MVF40CK Corner Kit View One Large Side Open, One Small Side Open 352 MGCKBL Grill Kit Corner Black (Two Sets) 147 MVF40SK See Through Kit View Two Large Sides Open 308 MGSKBL Grill Kit See Through Black (Two Sets) 180 MVF40PK Peninsula Kit View Two Large Sides Open, One Small Side Open 275 MGPKBL Grill Kit Peninsula Black (Three Sets) 228 Choose Your View and Grill Kit or Panel Kit: (Required for each unit) MVF40BK Bay Peninsula Kit View One Large Side Open, Two Small Sides Open 308 MGBKBL Grill Kit Bay Peninsula Black (Three Sets) 228 MVF40IK Island Kit View Four Sides Open $275 MGIKBL Grill Kit Island Black (Four Sets) 354 DECORATE THE BOTTOM OF YOUR FIREPLACE VLBIT4 Log Bits Large Four Piece Kit 111 VLBIT6 Log Bits Small Six Piece Kit 104 ACCESSORIES OPTIONAL MDV38RLE Refractory Liner End (Small Panel) 94 MDV38RLS Refractory Liner Side (Large Panel) 140 Z36SBL Surround Black (Coverage 34 1/2" H x 41 1/8" W) 242 Z36FK Fan Kit w/variable Speed Wall Mount Control (Temperature Sensing) 309 GTFRCN Remote Control Millivolt Thermostat/Modulating/Fan NG 537 GTFRCP Remote Control Millivolt Thermostat/Modulating/Fan LP 537

Page 56 ZERO CLEARANCE CLEAN VIEW CIRCULATING UNIVERSAL VENT FREE FIREBOX 39" WIDE ZVFCV39 Listed for USA, with Pull Screens, Framing 39 1/2" W x 37 5/16" H x 20 5/16" D $763 BURNER WITH GRATE (Required for each unit) GLVF24MAN Vent Free Gas Log Burner Manual Valve 38,250 BTU/HR Natural Gas 509 GLVF24MAP Vent Free Gas Log Burner Manual Valve 38,000 BTU/HR Propane 509 GLVF24MVN Vent Free Gas Log Burner Millivolt Valve 38,250 BTU/HR Natural Gas 730 GLVF24MVP Vent Free Gas Log Burner Millivolt Valve 38,000 BTU/HR Propane 730 LOG SET: (Required for each unit) LOGF18 Log Set Fiber Split Oak 18" 290 LOGF24 Log Set Fiber Split Oak 24" 335 SURROUNDS AND SAFETY SCREEN ZCV39S1BL Surround Hearth Mount 4" Wide (Covers 40 5/8" W x 35" H) 349 ZCV39S1PFBL Surround Picture Frame 4" Wide (Covers 40 5/8" W x 37" H) 349 ZCV39S2PFBL Surround Picture Frame 1 5/8" Wide (Covers 36 1/8" W x 32 1/2" H) 319 FIREPLACE ACCESSORIES OPTIONS: ZCV39RLT Refractory Fiber Brick Liner (3 PCE) Traditional 291 ZCV39RLH Refractory Fiber Brick Liner (3 PCE) Herringbone 291 ZCV39RRH Refractory Fiber Brick Liner (3 PCE) Red Herringbone 291 ZCV39RLS Refractory Fiber Brick Liner (3 PCE) Stacked Brick 291 Z46FK Fan Kit w/variable Speed Wall Mount Control (Temperature Sensing) 309 ULK2 Universal Light Kit Two Lamps 262 ZCV TLK Tile Lip Kit (for Finishing Materials tile, brick) 59 DECORATE THE BOTTOM OF YOUR FIREPLACE VLBIT4 Log Bits Large Four Piece Kit 111 VLBIT6 Log Bits Small Six Piece Kit 104 THERMOSTATS AND REMOTE CONTROLS FOR MILLIVOLT BURNERS GTFRCN Remote Control Millivolt Thermostat/Modulating/Fan NG 537 GTFRCP Remote Control Millivolt Thermostat/Modulating/Fan LP 537

Page 57 ZERO CLEARANCE CLEAN VIEW CIRCULATING UNIVERSAL VENT FREE FIREBOX 42" WIDE ZVFCV42 Listed for USA, with Pull Screens, Framing 42 1/2" W x 40 3/8" H x 20 5/16" D $842 BURNER WITH GRATE (Required for each unit) GLVF24MAN Vent Free Gas Log Burner Manual Valve 38,250 BTU/HR Natural Gas 509 GLVF24MAP Vent Free Gas Log Burner Manual Valve 38,000 BTU/HR Propane 509 GLVF24MVN Vent Free Gas Log Burner Millivolt Valve 38,250 BTU/HR Natural Gas 730 GLVF24MVP Vent Free Gas Log Burner Millivolt Valve 38,000 BTU/HR Propane 730 LOG SET: (Required for each unit) LOGF18 Log Set Fiber Split Oak 18" 290 LOGF24 Log Set Fiber Split Oak 24" 335 SURROUNDS ZCV42S1BL Surround Hearth Mount 4" Wide (Covers 44 5/8" W x 38 1/8" H) 396 ZCV42S1PFBL Surround Picture Frame 4" Wide (Covers 44 5/8" W x 40 1/8" H) 396 ZCV42S2PFBL Surround Picture Frame 1 5/8" Wide (Covers 40 1/8" W x 35 5/8" H) 349 FIREPLACE ACCESSORIES OPTIONS: ZCV42RLT Refractory Fiber Brick Liner (3 PCE) Traditional 319 ZCV42RLH Refractory Fiber Brick Liner (3 PCE) Herringbone 319 ZCV42RRH Refractory Fiber Brick Liner (3 PCE) Red Herringbone 319 ZCV42RLS Refractory Fiber Brick Liner (3 PCE) Stacked Brick 319 Z46FK Fan Kit w/variable Speed Wall Mount Control (Temperature Sensing) 309 ULK2 Universal Light Kit Two Lamps 262 ZCV TLK Tile Lip Kit (for Finishing Materials tile, brick) 59 DECORATE THE BOTTOM OF YOUR FIREPLACE VLBIT4 Log Bits Large Four Piece Kit 111 VLBIT6 Log Bits Small Six Piece Kit 104 THERMOSTATS AND REMOTE CONTROLS FOR MILLIVOLT BURNERS GTFRCN Remote Control Millivolt Thermostat/Modulating/Fan NG 537 GTFRCP Remote Control Millivolt Thermostat/Modulating/Fan LP 537

Page 58 ZERO CLEARANCE CLEAN VIEW CIRCULATING UNIVERSAL VENT FREE FIREBOX 47" Wide ZVFCV47 Listed for USA, with Pull Screens, Framing 48 1/2" W x 45 7/16" H x 22 5/8" D $954 BURNER WITH GRATE (Required for each unit) GLVF24MAN Vent Free Gas Log Burner Manual Valve 38,250 BTU/HR Natural Gas 509 GLVF24MAP Vent Free Gas Log Burner Manual Valve 38,000 BTU/HR Propane 509 GLVF24MVN Vent Free Gas Log Burner Millivolt Valve 38,250 BTU/HR Natural Gas 730 GLVF24MVP Vent Free Gas Log Burner Millivolt Valve 38,000 BTU/HR Propane 730 LOG SET: (Required for each unit) LOGF18 Log Set Fiber Split Oak 18" 290 LOGF24 Log Set Fiber Split Oak 24" 335 LOGF30 Log Set Fiber Split Oak 30" 472 SURROUNDS ZCV47S1BL Surround Hearth Mount 4" Wide (Coverage 50 9/16" W x 43 3/16" H) 445 FIREPLACE ACCESSORIES OPTIONS: ZCV47RLT Refractory Fiber Brick Liner (3 PCE) Traditional 395 ZCV47RLH Refractory Fiber Brick Liner (3 PCE) Herringbone 395 ZCV48RLT Refractory Fiber Brick Liner (3 PCE) Traditional 492 ZCV48RLH Refractory Fiber Brick Liner (3 PCE) Herringbone 492 ZCV48RLS Refractory Fiber Brick Liner (3 PCE) Stacked Brick 544 Z46FK Fan Kit w/variable Speed Wall Mount Control (Temperature Sensing) 309 ULK2 Universal Light Kit Two Lamps 262 ZCV TLK Tile Lip Kit (for Finishing Materials tile, brick) 59 DECORATE THE BOTTOM OF YOUR FIREPLACE VLBIT4 Log Bits Large Four Piece Kit 111 VLBIT6 Log Bits Small Six Piece Kit 104 THERMOSTATS AND REMOTE CONTROLS FOR MILLIVOLT BURNERS GTFRCN Remote Control Millivolt Thermostat/Modulating/Fan NG 537 GTFRCP Remote Control Millivolt Thermostat/Modulating/Fan LP 537

Page 59 FVF350 FREE STANDING VENT FREE STOVE 857 Listed for USA as a Vent Free Firebox, Black with Louver BURNER SYSTEM (REQUIRED FOR FVF350 STOVE) FVFB350MVN Vent Free Burner System Millivolt Valve 40,000 BTU/HR Natural Gas 695 FVFB350MVP Vent Free Burner System Millivolt Valve 40,000 BTU/HR Propane 695 DOOR FRAME (REQUIRED FOR EACH FVF350 STOVE) FVF350DB Door Frame Black and Fixed Mesh Screen 288 LOG SET: (REQUIRED FOR EACH FVF350 STOVE) LOGF35 Log Set Fiber Split Oak (F350,F300,IDV33) 342 ACCESSORIES: F45FK Fan Kit w/variable Speed Control (Temperature Sensing) 315 F35LG Louver Gold 125 GTFRCN Remote Control Millivolt Thermostat/Modulating/Fan NG 537 GTFRCP Remote Control Millivolt Thermostat/Modulating/Fan LP 537