µdim Microwave Sensors User Manual

Similar documents
PRODUCT DATA AND INSTALLATION SHEET MWS5-SA STAND ALONE MINIATURE CEILING MOUNTED MICROWAVE PRESENCE DETECTOR

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features

Analogue Dimming Microwave Presence/Absence Detector

SENSA MRE DDM MR

Direct Dim Microwave Presence/Absence Detector

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

SWITCHLITE MRE SLDM ADJ

MWS3A-PRM Product Guide

EBMHS (standard & slim-line PSU)

Product Guide. Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Integrated PIR detectors

, ,

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

MWS6-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

PPAD-C-230V. Ceiling PIR presence/absence detector. Product Guide. Overview. Features

Ceiling PIR HS presence detector. Product Guide. Overview. Features

LPC3BSP65 & LPC3BDP65

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

LPCMPIRM65 & LPCMPIRDSI65

MPAD-C 12-24V. Ceiling microwave presence/absence detector 12-24V AC/DC. Product Guide. Overview. Features

SWITCHLITE MRE SLD MAN SWITCHLITE MRE SLD IP55

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

VITMR-EBDSPIR-PRM. PIR Presence/Absence Detector IR with Ceiling Rose. Product Guide. Overview. Features

MWS3A-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC

EBDSPIR-PRM-2CH, EBDSPIR-PRM-2CH-NC

SWITCHLITE MRE DDM ADJ

EBDSPIR-PRM-LV Product Guide

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Ceiling Microwave presence/absence detector 12-24V AC/DC

Installation Guide. Ceiling PIR Detector (311) Features and Connections

MWS3 Ceiling Mount Microwave Occupancy Detector

Mounting bezel Retaining spring. Detects movement within the detection range, allowing load control in response to changes in room occupancy.

Sensors Explained AUTOMATION

IP65 High Bay Dual Sense Sensor

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

GI1DPC/B User Guide. Mains tungsten GLS filament or halogen lamp Min 60W Max 300W. Linear fluorescent

IP65 High Bay Dual Sense Sensor

Description FEATURES. l Innovative dual mount system requires only one sensor for either flush or surface mount applications

Tri-level Control HF Sensor

Standalone Presence Detectors

Tri-level Control HF Sensor

Built-in HF Sensor for High Bay

Tri-level Control Sensor

TOCR02 2 PART MICRO MOTION SENSOR W/IR REMOTE CONTROLLER

12W Round LED Wall/Ceiling Light with Microwave Sensor

Premium Version Tri-level Dimming Control

False Ceiling HF Sensors

18W Round LED Wall/Ceiling Light with Microwave Sensor

FR-A180 FR-A360. Occupancy detector. Use

II SL. Installation Guide. VOLTEX IMS64-2 Dual output indoor flush mount PIR motion detector IMS64-2

KingShield. - Occupancy Detectors NEW. For complete Lighting Control... ORION RANGE. P High performance for optimum switching of all types

360º FLUSH MOUNT CEILING PIR LIGHT CONTROLLER INSTALLATION & OPERATING. Cat No. SLFM360 INSTRUCTIONS

Detector switch - Dual Tech

Detector switch - Dual Tech SCS

e-sense move dali Manual

Model: MLSA360N. Installation & Operating Instructions. 360º Night Eye PIR Light Controller

Loop out. Ambient daylight threshold

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

60W Multi PIR Bulkhead

3. Intended use. 4. Function. 1. Product characteristics. 2. Safety. Functional description. Channel A light. Motion detector

2000W PIR LIGHT CONTROLLER SLB2000-Black SLW2000-White INSTALLATION & OPERATING INSTRUCTIONS

Daylight harvest function to regulate light output for maintaining required lux level

VERSION 2 VISION LIGHTING CONTROLS

Surface Mount Wall PIR Light Controller. Model: PDWM1500. Installation & Operating Instructions

Microwave Sensor. Basic Microwave Sensor. Energy Saving Motion Sensor. Introduction Features Technical Specification. 3 Dimensions

luxcontrol lighting control system basicdim basicdim ILD Compact control module with ambient light sensor and motion sensor

HF Motion Sensor Introduction

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

The two type sensors are innovative and active motion dimmable LED drivers or ballasts.

An-10 Wireless lighting control technology

An-10 Wireless lighting control technology

5 Litex Elite. Industrial. Up to 170Llm/cW. Mains lighting IK10

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Function description. Channel A light. Motion detector

11,9. Ordering data. Max. cable length sensor head 1 basicdim ILD lx 150 lx m 1

PMCSF6 OCCUPANCY SENSOR

North America Version / Dimming Function. Introduction

Product and Applications Description

BIANCO SENSOR FLUSH MOUNT 15W MODEL # GBCL400HFSR

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

CHALLENGER 66 INDUSTRIAL

Schneider Electric occupancy sensor range. Lighting the way to simple energy saving solutions

Integrated SensorDIM LED Driver Daylight Monitoring Version

360º Surface Mount Ceiling PIR Light Controller

For assistance with the product please contact: HELPLINE. For a product brochure please contact:

LED Compatible Daylight Harvesting and Motion Sensor System

Installation Instructions

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor

Introduction. Dimming Function MC003V (Standard Version) MC003V R (Reinforced Version)

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

Infrared Ceiling Mount Sensor

Transcription:

Microwave Sensors User Manual P e o p l e I n n o v a t i o n s S o l u t i o n s

1. Introduction µdim Table of Contents Page Introduction 2 Technical data 3 Dimensions and mounting options 9 Connections 10 Setup 11 Programmming 12 Fault finding 14 μdim Microwave Sensors The μdim series of miniature microwave presence detectors provide automatic control of lighting loads with optional manual control. The unit comes complete with a selection of fixing clips, allowing unobtrusive flush mounting of the sensor head into ceiling tiles or on to solid surfaces. It has been designed so that it can be used for ceiling mounted or wall mounted applications. As microwave radiation penetrates plastic and glass, this unit has been specifically designed to be mounted inside a luminaire. Three versions are available: switched, 1-10V analogue, and DALI. All of which will switch incandescent, fluorescent and compact fluorescent lighting. The unit detects movement using a microwave sensor and turns the load on. When an area is no longer occupied the load will switch off after an adjustable time out period has elapsed. Feature SL-MW-SW SL-MW-AN SL-MW-DA Up to 8m microwave sensing Lux sensor Presence detection Infrared remote setting Relay output 1-10 V Dimming output - - DALI Dimming output - - 2

SL-MW-SW µdim Microwave Switching Sensor The SL-MW-SW miniature microwave presence detector provides automatic control of lighting loads. The unit comes complete with a flush-mount bracket, allowing unobtrusive mounting of the sensor head into ceiling tiles or onto solid surfaces. It has been designed so that it can be used for luminaire mounted or ceiling mounted applications. As microwave radiation penetrates plastic and glass, this unit has been specifically designed to be mounted inside a luminaire. The product consists of the following : Sensor head with integral RJ11 sensor lead Power supply unit Flush mount bracket 2. Technical Data Presence detection: when movement is detected the load will automatically turn on; when the area is no longer occupied the load will automatically switch off after an adjustable time period. 1) No presence detected, daylight, lights OFF 2) Presence detected,sufficient daylight, lights OFF 3) Presence detected, insufficient daylight, lights ON 4) No presence detected, night time, lights OFF 3

SL-MW-SW µdim Microwave Switching Sensor Technical specifications Sensor head 2. Technical Data Supply voltage Max load capacity Light level Connections Terminals (supply unit) 220-240 V AC, 50 Hz 2 A Light to dark Integral RJ11 cable between supply unit and sensor head 1.5mm 2 (solid core cable only) Material Sensor head, surface mount baseplate, flush bracket Flame retardant ABS Flange mount bracket & Lens PMMA (Clear acrylic) Power supply unit housing Flame retardant polycarbonate Type Class 2 Operating Temperature -10 C to 50 C Lens Recommended mounting location Green LED - time Red LED - lux / presence setting indicator Yellow LED - sensitivity / absence setting indicator SAFETY The microwave radiation emitted by these units is extremely low power. At a distance of > 50mm the power density is <6% of the ANSI IEEE C95.1 1991 recommended microwave power density. At a distance of 5mm from the unit it is <84% of recommended power density. Conformity Detection area EMC-89/336/EEC LVD-73/23/EEC Avoid direct sunlight entering the sensor Do not site within 1m of forced air heating or ventilation. Do not fix to a vibrating surface. Avoid metallic objects directly in front of the sensor head. Do not fit to a suspended luminaire When installing the sensor head behind a glass / polycarbonate diffuser will reduce the detection range by approximately 20%. Note: On maximum sensitivity, the detector unit is extremely sensitive to movement and may detect through glass, thin walls or partitions. If this causes a problem, reduce its sensitivity using the SA-IR-PROG 2.8m Programmer. 8m 5m 12m 4

SL-MW-AN µdim Microwave 1-10V Sensor The SL-MW-AN miniature microwave presence detector provides automatic control of lighting loads. The unit comes complete with a flush-mount bracket, allowing unobtrusive mounting of the sensor head into ceiling tiles or onto solid surfaces. It has been designed so that it can be used for luminaire mounted or ceiling mounted applications. As microwave radiation penetrates plastic and glass, this unit has been specifically designed to be mounted inside a luminaire. The product consists of the following : Sensor head with integral RJ11 sensor lead Power supply unit Flush mount bracket 2. Technical Data Presence detection: when movement is detected the load will automatically turn on; when the area is no longer occupied the load will automatically switch off after an adjustable time period. 3) Presence detected some daylight. Lights on and dimmed to maintain lux level 1) No presence detected, daylight, lights OFF 4) Presence detected, insufficient daylight. Detector measures and implements maintained illumininance 2) Presence detected,sufficient daylight, lights OFF 5) No presence detected, night time, lights OFF 5

SL-MW-AN µdim Microwave 1-10V Sensor Technical specifications Sensor head 2. Technical Data Supply voltage Max load capacity Light level Connections Terminals (supply unit) 220-240 V AC, 50 Hz Relay Output - 2 A Dimmed Output - 4 x 1-10V ballasts Light to dark Integral RJ11 cable between supply unit and sensor head 1.5mm 2 (solid core cable only) Material Sensor head, surface mount baseplate, flush bracket Flame retardant ABS Flange mount bracket & Lens PMMA (Clear acrylic) Power supply unit housing Flame retardant polycarbonate Lens Recommended mounting location Green LED - time Red LED - lux / presence setting indicator Yellow LED - sensitivity / absence setting indicator Type Class 2 Operating Temperature -10 C to 50 C SAFETY The microwave radiation emitted by these units is extremely low power. At a distance of > 50mm the power density is <6% of the ANSI IEEE C95.1 1991 recommended microwave power density. At a distance of 5mm from the unit it is <84% of recommended power density. Conformity Detection area EMC-89/336/EEC LVD-73/23/EEC Avoid direct sunlight entering the sensor Do not site within 1m of forced air heating or ventilation. Do not fix to a vibrating surface. Avoid metallic objects directly in front of the sensor head. Do not fit to a suspended luminaire When installing the sensor head behind a glass / polycarbonate diffuser will reduce the detection range by approximately 20%. 2.8m Note: On maximum sensitivity, the detector unit is extremely sensitive to movement and may detect through glass, thin walls or partitions. If this causes a problem, reduce its sensitivity using the SA-IR-PROG Programmer. 8m 5m 12m 6

SL-MW-DA µdim Microwave DALI Sensor The SL-MW-DA miniature microwave presence detector provides automatic control of lighting loads. The unit comes complete with a flush-mount bracket, allowing unobtrusive mounting of the sensor head into ceiling tiles or onto solid surfaces. It has been designed so that it can be used for luminaire mounted or ceiling mounted applications. As microwave radiation penetrates plastic and glass, this unit has been specifically designed to be mounted inside a luminaire. The product consists of the following : Sensor head with integral RJ11 sensor lead Power supply unit Flush mount bracket 2. Technical Data Presence detection: when movement is detected the load will automatically turn on; when the area is no longer occupied the load will automatically switch off after an adjustable time period. 3) Presence detected some daylight. Lights on and dimmed to maintain lux level 1) No presence detected, daylight, lights OFF 4) Presence detected, insufficient daylight. Detector measures and implements maintained illumininance 2) Presence detected,sufficient daylight, lights OFF 5) No presence detected, night time, lights OFF 7

SL-MW-DA µdim Microwave DALI Sensor Technical specifications Sensor head 2. Technical Data Supply voltage Max load capacity Light level Connections Terminals (supply unit) 220-240 V AC, 50 Hz Relay Output - 2 A Dimmed Output - 4 x DALI ballasts Light to dark Integral RJ11 cable between supply unit and sensor head 1.5mm 2 (solid core cable only) Material Sensor head, surface mount baseplate, flush bracket Flame retardant ABS Flange mount bracket & Lens PMMA (Clear acrylic) Power supply unit housing Flame retardant polycarbonate Lens Recommended mounting location Green LED - time Red LED - lux / presence setting indicator Yellow LED - sensitivity / absence setting indicator Type Class 2 Operating Temperature -10 C to 50 C SAFETY The microwave radiation emitted by these units is extremely low power. At a distance of > 50mm the power density is <6% of the ANSI IEEE C95.1 1991 recommended microwave power density. At a distance of 5mm from the unit it is <84% of recommended power density. Conformity Detection area EMC-89/336/EEC LVD-73/23/EEC Avoid direct sunlight entering the sensor Do not site within 1m of forced air heating or ventilation. Do not fix to a vibrating surface. Avoid metallic objects directly in front of the sensor head. Do not fit to a suspended luminaire When installing the sensor head behind a glass / polycarbonate diffuser will reduce the detection range by approximately 20%. Note: On maximum sensitivity, the detector unit is extremely sensitive to movement and may detect through glass, thin walls or partitions. If this causes a problem, reduce its sensitivity using the SA-IR-PROG 2.8m Programmer. 8m 5m 12m 8

Dimensions & Mounting options Sensor head 3 300 o 4mm o 11mm 39 19 18 19 1.5 Fixing lugs for bulkhead fitting Bulkhead plate max. thickness 1mm Details for using bulkhead fixing lugs Power supply unit 133 22.5 145 Flush mounting the sensor head using the flush mount bracket The product can be mounted into a flat panel of a luminaire using the flush mount bracket as shown below. If flush mounting in a panel that is greater than 6mm thick, remove bottom of retention arms with side cutters. A 44mm diameter hole will be required in the panel to mount the flush mount bracket. 20.5 3. Dimensions 44 44 mm 6 mm 9

Connections Connect the power supply via the terminal block on the power supply unit as shown overleaf. Live supply to the L terminal, Neutral to the N terminal and the load to the LIVE OUT (L/out) terminal. Connect the sensor head to the power supply unit using the RJ11 connector, ensuring it clicks in place. In the case of dimming applications, connect the D+ and D_ connections to the corresponding terminals on the luminaire dimming ballast. On power up, the load should come on immediately. Vacate the room or remain very still and wait for the load to switch off (on the factory preset, this should take approximately 15 minutes, but the timing out period can be adjusted down to 1 minute to help speed up the setup procedure please see next section for details on set-up & adjustment). Check that the load switches on when movement is detected. SL-MW-SW Sensor head Power supply unit N LOAD max 2A L SL-MW-AN Sensor head 4. Connections LOAD max 2A N L 1-10V Ballast N L C0(-) C1(+) Power supply unit SL-MW-DA Sensor head LOAD max 2A N L Power supply unit DA+ DA- DALI Ballast N L 10

Setup Positioning The detector should be sited so that the occupants of the room fall inside the detection pattern shown in picture. Please note that when ceiling mounting, the recommended ceiling height of the sensor head is 2.4m. Note that the lower the sensor is installed the smaller the detection range will be, subject to the parameters shown on the diagram. Avoid direct sunlight entering the sensor. Do not site within 1m of forced air heating or ventilation. Do not fix to a vibrating surface. Avoid metallic objects directly in front of the sensor head. Do not fit to a suspended luminaire. Settings adjustment:- On initial power up, the factory set default settings are:- Time = 20 minutes. Lux = Maximum (i.e. lights will switch on in full daylight on detection). Sensitivity = Maximum. 8m 2.8m 5m Time All versions set the time period using the programming handset (see section 6). The factory default is 20 minutes. 12m Lux SL-MW-SW the switch level on lux setting determines the ambient light level at which the lights turn on. This can be set using the programming handset (see section 6). Setting to maximum (level 7) ensures that lights always come on (this is also the default setting). SL-MW-AN/DA switch level on described above is available using the programming handset only. The push button lux adjustment determines the dimming output level and can be set using push button the programming handset light level and works as follows: During operation the output level varies very gradually. However when the level is changed the unit automatically enters setup mode: in this mode the output level varies rapidly. After the setup time the unit reverts to normal. When adjusting, allow the output level to settle by changing very gradually. To disable the constant light function completely, set the level to maximum. 5. Setup 11

Programming All the following functions can be programmed using the SA-IR-PROG handset: Number of Shift key presses Preset functions 0 1 2 3 Programmer Graphics Description SHIFT 1 SHIFT 2 SHIFT 1 SHIFT 2 SHIFT 1 SHIFT 2 SHIFT 1 SHIFT 2 Button Activation On / Raise On Raise Turn lights on or to raise lights. Off / Lower Off Low er Turn lights off or to lower lights. Walk test On Off When set to On this causes a red LED to flash on the sensor when it detects mov ement. Use this f eature to check f or adequate sensitiv ity lev els. Time Out (Time adjustment) Lux on level (Switch level on) 1, 10 & 20 minutes 5, 15 & 30 minutes 10 seconds Once the detector is turned on, this v alue sets how long the lights will stay on once mov ement has ceased. 2, 5 & 7 4, 6 & 9 Lux lev el setting to prev ent the luminaires being switched on if the ambient light lev el is sufficient (adjustable between 1 and 9). The luminaires will alway s be switched on at lev el 9. Light Level 2 (200) 5 (500) 7 (700) Lux off level (Switch level off) 4 (400) 6 (600) 9 (900) Sets a target light lev el to be maintained by the lighting system. 2, 5 & 7 4, 6 & 9 Lux lev el setting to switch the luminaires off during occupancy if the ambient light lev el goes abov e the setting (adjustable between 1 and 9). Lev el 9 will alway s keep the lights on. This setting can be used for window row switching. Sensitivity 1, 5 & 9 3, 6 & 8 Sensitiv ity lev el f or detecting mov ement. 1 = low sensitiv ity 9 = high sensitiv ity Defaults D Returns the unit to the def ault settings. Burn-in 0 50 100 Determines how long the output will be at 100% so that lamps burn-in. The burn-in time is not aff ected by power supply interruptions. Shift Use this button to select the settings in red and blue signif ied by the Shif t 1 and Shift 2 LEDs 6. Programming 12

13

Fault finding LOAD DOES NOT COME ON LIGHTS DO NOT GO OFF Check to see if the live supply to the circuit is good. Strap across the L and LIVE OUT (where used) terminal to turn the load on. Ensure that the area is left unoccupied for longer than the selected timer setting. If the supply and wiring are good, check the LUX level setting. Increase the LUX level setting to allow the controller to turn on at higher ambient natural light level. If the detection range is smaller than expected, check the diagram above. Rotating the sensor slightly may improve the range. Make sure that the sensor is not adjacent to circulating air, heaters or lamps. If the unit false triggers reduce the sensitivity using the sensitivity settings (see section 4 and 5). Part numbers SL-MW-SW SL-MW-AN SL-MW-DA Miniature PIR with switched (relay) output Miniature PIR with 1-10V Analogue and switched (relay) output Miniature PIR with DALI and switched (relay) output Accessories SA-IR-PROG IR programming handset Helvar Oy Ab Yrittäjäntie 23, P.O.Box 100 FI-03601 Karkkila Finland www.helvar.com FI: +358 9 56 54 1 UK: +44 1322 222 211 SE: +46 8 545 239 70 FR: +33 1 3418 1281 IT: +39 02 55 30 10 33 DE: +49 6104 78075 RU: +7 (495) 728 82 91 HU: +36 1 2393 136 CN: + 86 512 6763 3078 IMPORTANT NOTICE! This device should be installed by a qualified electrician in accordance with the latest edition of the IEE wiring regulations. Product: µdim Microwave sensors User Manual Doc No. T13 144 1C Issue 2 Product not to be used in the U.S.A. 14