LINDOFLAMM thermal engineering.

Similar documents
Cold water HD 9/18-4 ST

U tube models PTU 09, 12, 15, 25, 30, 35, 40, 45. single linear tube models PTS 09, 12, 15, 25, 30, 35, 40, 45

NEPTUNE 1. Model: NEPTUNE Part List English

High pressure cleaning heads cleanliness all around

HD Kompakt Service Manual

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

Granule Gastro/Combi

WHU WATER HEATING UNITS. GENERAL MANUAL MODEL KEY. June 2007 WHU WATER HEATING UNITS

TOP AND CONSOLE PARTS

HDC Standard. Stationary high-pressure cleaner for the simultaneous use of 2 to 8 take-off points. Modular design. Intelligent pump control

Wallis & Stevens 7C. hand operated sprayer for cold bitumen emulsion. Contact: Sales at BX Plant on or

Wall-hung boilers. Spare parts catalogue. ecotec plus

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

SCC 101 G Valid as of G11SE0404 up to G11SE... SCC 101 G

Hakki Pilke Raven spare parts manual

BCP & BCM COMBI OVENS REPLACEMENT PARTS LIST

FLAT FLAME AND EXCESS AIR BURNERS

Parts and Service Manual

Cold water compact class HD 5/12 C

27" GAS DRYER MODELS: WGD95HEDW0 (White) WGD95HEDC0 (Chrome Shadow) 05/13/ Whirlpool Corporation Part No. W Rev.

SCC 201E Valid as of E21SE0404 up to E21SE... SCC 201E

27" GAS DRYER MODELS: 7MWGD87HEDC0 (Chrome Shadow) 08/19/ Whirlpool Corporation Part No. W Rev. A

Floor Standing Bath Shower Mixer. Fitting instructions. Please keep these instructions for future reference and request of replacement parts.

Installation guide Nordic mixer taps. Before installing read this guide first

NEPTUNE 2. Model: NEPTUNE 2-13 NEPTUNE 2-20 NEPTUNE 2-25 NEPTUNE 2-26 NEPTUNE 2-30 NEPTUNE 2-33 NEPTUNE 2-38 NEPTUNE Part List US-English

Oil burners fuel unit with solenoid valve

HD 7/11-4 Cage Classic

PARTS BOOK. From S/N:

K 2 Compact. K 2 Compact, ,

INTRODUCTION THIS MANUAL INCLUDES IMPORTANT SAFETY INFORMATION

Grant Spira 6-26kW and 9-36kW Wood Pellet Boilers

27" GAS DRYER MODELS: MGD7100DW0 (White) MGD7100DC0 (Chrome Shadow) 05/08/ Maytag Part No. W Rev. A

GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS. Spare parts suitable for LA CIMBALI

HDS 1000 BE EASY! Optimum ease of use. Maximum performance. Automatic burner cut-out in case of water shortage, overheating protection.

SECTION 1 - INSTALLATION UNLESS OTHERWISE STATED, PARTS WHICH HAVE BEEN PROTECTED BY THE MANUFACTURER ARE NOT TO BE ADJUSTED BY THE INSTALLER 1.1 MODE

CATALOG OF REPLACEMENT PARTS HSROG SERIES SINGLE RACK OVEN. A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO

TC MODULE (FFD) (with Gas Hob)

27" Gas Dryer MODELS: MGDB950YW3 (White) MGDB950YG3 (Cosmetallic) 05/31/ Maytag Part No. W Rev. A

SCC 61 E Valid as of E61SE0404 up to E61SE... SCC 61 E

Venco 75mm (3 ) Standard and De-airing Pugmill

Operating instructions

HORIZONTAL COOKING SERIES: 700 / 900 S.A.V MAINTENANCE & AFTER SALES WORK PPS-3WE711911CH

ALTO POSEIDON 5 WHY COMPROMISE The silent and efficient cold water high pressure cleaner

K K 2.120, ,

Weishaupt dual fuel burners Sizes 30 to 70 Version 1LN (NO X -reduction on gas operation) 1/2003 CA

TOX -Spray System SP. Data sheet /

Service manual IC LF/FLF/R/FR. Flatwork ironers

GASTEC QA. Approval Requirements 69-1

Propane Heater REMKO PGM 30 REMKO PGM 60

HD 5/12 C Plus. Compact, high performance pressure washer with unique stand-up or lay-flat operating positon and large carry handle.

HD 5/12 C + Mobility. Accessory storage

Hot water compact class HDS 5/12 C *AU

Single stage operation oil burner

VAILLANT SPARE PART CATALOGUE

HDS 7/16 C. Mobility. Efficiency

UL/FM Fire Protection Products. Reliable fire protection products for your commercial, industrial, or institutional property.

MODEL CMA-180UC PARTS MANUAL Rev 1.18

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

Water Safety Shut-Off Valve HON 790. Product information. serving the gas industry worldwide

Operating instructions. Web Cleaner 1 / 2. Air Line

Contents authorised persons

GAS HEATERS Models: Little Devil (inc ss), Devil 650/660(ss), Devil 850/860(ss), Devil 1250/1260(ss), Devil 1850, Devil 3000 & Devil 3150

Connection set. Radiator connection set for thermostatic and manual operation Ø 12

Xpert HD Xpert HD 7140, ,

HD 7/11-4 Classic. Durable and robust. Improved cleaning performance. Especially easy to maintain. Excellent mobility

GAS RESTAURANT RANGE MODELS 24L, 36L/LC, 48L, 481L/LC, 148L/LC, 60 L/LC/LCC, 160L/LC, 260L/LC/LCC

15 20 kw kw kw

EKO Line Pellet Boiler Wood Pellet Storage Solutions And Pellet Dosage Systems

RETROFIT APPLICATIONS ONLY

MULTIPLEX SELF RECUPERATIVE gas burner

OPERATING INSTRUCTIONS. Automatic welding machine LARON Version 2.1

Synergy Grill User & Engineer Installation & Conversion Guide

Installation Manual PS-200 & PS-201

Moisture inside the drum is due to final testing.

Installation Instructions for P/N: Algas-SDI thermostat retrofit kit

THE WHOLE WORLD OF AUTOGENOUS ENGINEERING

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function

Global-Tek (Singapore) Pte Ltd

INSTRUCTION MANUAL FOR OIL BURNER MODELS

HDS 6/14 C. Large tilting aid. eco!efficiency mode. Economical and environmentally friendly even during longer periods

HD 6/15-4 Classic. Durable and robust. Improved cleaning performance. Especially easy to maintain. Excellent mobility

Installation and Operating Instructions

Cold water compact class HD 6/13 C Plus *EU

GAS GRIDDLE INSTRUCTIONS MODEL: PGF GRIDDLES PGF 300, 600, 800, 1200

UL/FM Fire Protection Products. Reliable fire protection products for your commercial, industrial, or institutional property.

K K 2.100, ,

PACKAGED METALLIC BURNERS

COMMERCIAL STACKED GAS DRYER/WASHER

SPECIAL PRICE PROMOTION. WORKSHOP EQUIPMENT. CLEANING EQUIPMENT; WELDING RIG; WELDING SAFETY WALL.

INSTALLATION GUIDE NZ AU E

Installation Manual PS-225 & PS-275

TECHNICAL INSTRUCTIONS

K 4 Compact. K 4 Compact, ,

SuperKlean Washdown Products

TopVent Design Handbook

INSTRUCTION MANUAL FOR OIL BURNER MODELS

INSTRUCTION MANUAL FOR OIL BURNER MODELS

Semi-Automatic Suction Screen Filters 3"-4 Angle. Service & Maintenance Manual

JANUS 3 CIRCULATOR WATER HEATER INSTALLATION, COMMISSIONING & SERVICING INSTRUCTIONS G.C. No

ProCon Streamline Gas Condensing Boiler. Installation and Operating Manual.

Transcription:

Catalogue LINDOFLAMM thermal engineering. Tailored solutions for every heating application.

02 LINDOFLAMM thermal engineering. Tailored solutions for every heating application. Contents. 03 All-round offering 04 High-performance burner LF-H-4 to LF-H-16 (hand-operated) 05 High-performance LF-H-2D burner (hand-operated) 06 Acetylene/compressed air round head burner 07 Lance burner 08 Short lance burner 09 Handles 10 Machine shafts 11 Feed with mixing chamber and injector 12 Ball valves 13 Elbow joints 14 Flanges 15 Distributor 16 Adjusting valves 17 Ignition flame 18 Spare parts 19 All-round support. First-class services for LINDOFLAMM special burner applications.

LINDOFLAMM thermal engineering. Tailored solutions for every heating application. 03 All-round offering. AGA s range of LINDOFLAMM special burners has the perfect fit for every heating application. Our all-round heating solutions for semi- and fully-automated heating processes are tailored to customer requirements and deliver outstanding results. At the heart of each heating installation is the LINDOFLAMM burner. Further components and services from automatic ignition to monitoring, temperature control and documentation put the perfect finish on our offering. Our application engineers provide expert advice and work with customers to develop the right solution every time. They also start up installations and provide training on their correct operation. In addition to these services, we can also advise on and deliver the supporting gas supply system making AGA the preferred provider for all gas supply and heating needs.

04 LINDOFLAMM thermal engineering. Tailored solutions for every heating application. High-performance burner LF-H-4 to LF-H-16 (hand-operated). Burner type Gases Operating pressure bar Consumption* m³/h Handle Overall length L/mm Flame field Ø/mm LF-H-4 Acetylene 0.8 1.4 1.9 LF-S-3-H 375 10 100.004 Oxygen 2.5 3.5 1.6 2.2 LF-H-6 Acetylene 0.8 3.3 4.5 440 16 100.006 Oxygen 2.5 4.0 3.8 5.2 LF-H-8 Acetylene 1.0 5.0 7.1 500 18 100.008 Oxygen 2.5 4.0 5.8 8.9 LF-H-16 Acetylene 1.2 12.4 15.9 LF-S-4-H 650 28 100.016 Oxygen 3.5 5.0 14.3 18.3 Heating applications for large workpieces Flame straightening of large sheet thicknesses Thorough heating of heat wedges Fusing flame-sprayed coatings Heat-shaping of thick-walled plates, pipes and profiles Achieving high temperatures during heating Burner head at 45º angle with reinforcement between the mixer and feeder shaft Gas-cooled burner Injector with O-rings for internal and external tightness Brazed components for extra strength Extension options Ball valves on handle for quick opening/closing and reproducible flame adjustment * The consumption values, measured at the burner inlet, are related to the burner s power range. By altering the gas flow rate, the power in the specified range can be adjusted to the corresponding tasks. The consumption data should be noted when constructing the gas supply. The operating instructions contain further information about operating LINDOFLAMM burners. Our specialists are always available to provide further information.

LINDOFLAMM thermal engineering. Tailored solutions for every heating application. 05 High-performance LF-H-2D burner (hand-operated). Burner type Gases Operating pressure bar Consumption* m³/h Handle Overall length L/mm Flame field Ø/mm LF-H-2D Acetylene 0.6 0.8 1.7 LF-S-2-H 650 23 100.002 Compressed Air 2.0 4.0 5.6 11.9 Pre-heating components before welding and cutting Drying the area around a weld seam Maintaining interpass temperatures Post-heating Burner head at 45º angle with reinforcement between the mixer and feeder shaft Gas-cooled burner Injector with O-rings for external tightness Brazed components for extra strength Extension options Ball valves on handle for quick opening/closing and reproducible flame adjustment * The consumption values, measured at the burner inlet, are related to the burner s power range. By altering the gas flow rate, the power in the specified range can be adjusted to the corresponding tasks. The consumption data should be noted when constructing the gas supply. The operating instructions contain further information about operating LINDOFLAMM burners. Our specialists are always available to provide further information.

06 LINDOFLAMM thermal engineering. Tailored solutions for every heating application. Acetylene/compressed air round head burner. Burner type Gases Operating pressure bar Consumption* m³/h Number of nozzles Connecting thread in. Handle Overall length mm LF-H-2D-K Acetylene 0.6 0.8 1.7 9 1/2 LH LF-S-2-H 218 200.002 Compressed 2.0 4.0 5.6 11.9 Air Stationary pre-heating before welding and cutting Drying before welding Maintaining interpass temperatures Post-heating Burner head at 45º angle Nozzles arranged in a ring on the burner head Combination of several round heads available for large flame fields Mandatory additional equipment Gas mixture distributor Feed with mixing chamber Handle or machine shaft Extension options Ignition flame to start up the burner Ball valves or solenoid valves for reproducible results * The consumption values, measured at the burner inlet, are related to the burner s power range. By altering the gas flow rate, the power in the specified range can be adjusted to the corresponding tasks. The consumption data should be noted when constructing the gas supply. The operating instructions contain further information about operating LINDOFLAMM burners. Our specialists are always available to provide further information.

LINDOFLAMM thermal engineering. Tailored solutions for every heating application. 07 Lance burner. Burner type Gases Operating pressure bar Consumption* m³/h Number of nozzles Machine shaft Overall length mm Burner height mm LF-M-16D Acetylene 0.8 1.0 1.3 2.3 16 LF-S-2-M 500 100 200.016 Compressed 2.0 4.0 9.0 17.1 Air LF-M-33D Acetylene 0.8 1.0 2.4 4.4 33 1010 200.033 Compressed Air 2.0 4.0 17.2 31.5 Stationary pre-heating before welding and cutting Drying before welding Maintaining interpass temperatures Post-heating Elongated construction with exchangeable nozzles Nozzles arranged in a row Bolted flange connections enable several burner elements to be connected (max. length 2m) Parallel operation via distributors and bridges (max. number of nozzles: 66) Mandatory additional equipment Flange Feed with mixing chamber Machine shaft Extension options Optional automation using pilot flame and monitoring elements (flame monitoring, temperature monitoring, data capture systems, etc.) Ball valves or solenoid valves for reproducible results Gas mixture distributor * The consumption values, measured at the burner inlet, are related to the burner s power range. By altering the gas flow rate, the power in the specified range can be adjusted to the corresponding tasks. The consumption data should be noted when constructing the gas supply. The operating instructions contain further information about operating LINDOFLAMM burners. Our specialists are always available to provide further information.

08 LINDOFLAMM thermal engineering. Tailored solutions for every heating application. Short lance burner. Burner type Gases Operating pressure bar Consumption* m³/h Number of nozzles Connecting thread in. Machine shaft Overall length mm Burner height mm LF-M-8D Acetylene 0.8 1.0 0.7 1.3 8 1/2 LH LF-S-2-M 240 110 200.008 Compressed 2.0 4.0 5.3 9.4 Air LF-M-12D Acetylene 0.8 1.0 1.0 1.9 12 1/2 LH 360 110 200.012 Compressed Air 2.0 4.0 7.5 13.8 Stationary pre-heating before welding and cutting Drying before welding Maintaining interpass temperatures Post-heating Lightweight construction with exchangeable nozzles Nozzles arranged in a row Combination of several short lances available to cover a large flame field Heat shield made of heat-resistant steel Mandatory additional equipment Feed with mixing chamber Machine shaft Extension options Optional automation using pilot flame, ignition electrode and monitoring elements (flame monitoring, temperature monitoring, data capture systems, etc.) Ball valves or solenoid valves for reproducible results Gas mixture distributor * The consumption values, measured at the burner inlet, are related to the burner s power range. By altering the gas flow rate, the power in the specified range can be adjusted to the corresponding tasks. The consumption data should be noted when constructing the gas supply. The operating instructions contain further information about operating LINDOFLAMM burners. Our specialists are always available to provide further information.

LINDOFLAMM thermal engineering. Tailored solutions for every heating application. 09 Handles. Handle with connection for: Connecting thread in. Inner Ø of hose mm (ISO 3821) Special burner LF-S-2-H 3/8 LH 9.5 LF-H-2D 300.002 3/8 RH 9.5 LF-S-3-H 3/8 LH 9.5 LF-H-4, LF-H-6, LF-H-8 300.003 1/4 RH 6.3 LF-S-4-H 1/2 LH 12.5 LF-H-16 300.004 3/8 RH 9.5 Extension options To adjust the consumption of acetylene-oxygen/ compressed air series LF-H burners Ball valves on handle for quick opening/closing and a reproducible flame Ergonomic design ensures ease of use as well as comfortable, fatigue-free operation Furthermore the sturdy construction ensures that the handles have a long life The self-tightening radial seals at the inserts guarantee a quick and secure seal * The consumption values, measured at the burner inlet, are related to the burner s power range. By altering the gas flow rate, the power in the specified range can be adjusted to the corresponding tasks. The consumption data should be noted when constructing the gas supply. The operating instructions contain further information about operating LINDOFLAMM burners. Our specialists are always available to provide further information.

10 LINDOFLAMM thermal engineering. Tailored solutions for every heating application. Machine shafts. Machine shaft for use with: Connecting thread in. Inner Ø of hose mm (ISO 3821) Special burner LF-S-2-M 3/8 LH 9.5 LF-M-8D, LF-M-12D, 3/8 RH 9.5 LF-M-16D, LF-M-33D Area of application (number of nozzles) 8 66 400.002 Adjusting the consumption of LF-M series acetylene-compressed air burners with 8 66 nozzles Extension options Solenoid valves can be used instead of ball valves for automated heating applications. Brass machine shaft with integrated compressed air manometer, adjusting valves and ball valves The self-tightening radial seals at the inserts guarantee a quick, secure seal

LINDOFLAMM thermal engineering. Tailored solutions for every heating application. 11 Feed with mixing chamber and injector. Feed Connecting thread in. Length mm External Ø mm Area of application (number of nozzles) LF-S-2 F1 1/2 LH 300 16 8 12 400.021 LF-S-2 F2 1/2 LH 500 16 8 12 400.022 LF-S-2 F3 1/2 LH 300 16 13 24 400.023 LF-S-2 F4 1/2 LH 500 16 13 24 400.024 LF-S-2 F5 1/2 LH 300 16 25 41 400.025 LF-S-2 F6 1/2 LH 500 16 25 41 400.026 LF-S-2 F7 1/2 LH 300 16 41 57 400.027 LF-S-2 F8 1/2 LH 500 16 41 57 400.028 LF-S-2 F9 1/2 LH 300 16 58 66 400.029 LF-S-2 F10 1/2 LH 500 16 58 66 400.030 Using an injector to mix acetylene and compressed air Feeding the acetylene-compressed air mixture to the round head, lance or short lance burner Injector with O-rings for external tightness Brazed component joints

12 LINDOFLAMM thermal engineering. Tailored solutions for every heating application. Ball valves. Gases Connecting thread Nominal size Handle/machine shaft in. Acetylene 3/8 LH DN 6 LF-S-2-H, LF-S-3-H, 500.001 LF-S-5-H, LF-S-6-H Acetylene 3/8 LH DN 10 LF-S-2-M 500.002 Acetylene 1/2 LH DN 10 LF-S-4-H 500.003 Compressed air 3/8 RH DN 6 LF-S-2-H 500.004 Compressed air 3/8 RH DN 10 LF-S-2-M 500.005 Oxygen 1/4 RH DN 6 LF-S-3-H, LF-S-5-H 500.006 Oxygen 3/8 RH DN 10 LF-S-4-H, LF-S-6-H 500.007 For the quick shutting off of acetylene, oxygen and compressed air Reproducible flame adjustment The ball valves are made of chrome-plated brass and are equipped with double threaded connections in accordance with EN 560

LINDOFLAMM thermal engineering. Tailored solutions for every heating application. 13 Elbow joints. Connecting thread in. 3/8 RH 501.001 3/8 LH 501.002 1/2 RH 501.003 1/2 LH 501.004 Connecting feeds with burners, tubes with machine shafts or feeds with distributors The elbow joints are made of brass in accordance with EN 560

14 LINDOFLAMM thermal engineering. Tailored solutions for every heating application. Flanges. End flange Output flange Input flange Lance burners with connector Flange Connecting thread in. Input flange 1/2 LH 502.001 Output flange 1/2 LH 502.002 End flange 502.003 Connector 502.004 Joining, closing and connecting lance burners The flanges are made of brass and equipped with O-rings

LINDOFLAMM thermal engineering. Tailored solutions for every heating application. 15 Distributor. 150mm bridge 100mm input distributor 150mm input distributor Connection distance Input connecting thread in. Output connecting thread in. Number of output connectors 150mm input 1/2 LH 1/2 LH 2 503.001 distributor 150mm bridge 1/2 LH 2 503.002 100mm input distributor 1/2 LH 1/2 LH 3 503.003 Operating round head, lance or short lance burners in parallel Brass distributor with or without input connector Lance burners with 150mm input distributor and 150mm bridge

16 LINDOFLAMM thermal engineering. Tailored solutions for every heating application. Adjusting valves. Acetylene valve Compressed air valve Gases Connecting thread in. Nominal size Max. operating pressure bar Acetylene 3/8 LH DN 9 1.5 504.001 Compressed air 3/8 RH DN 9 40 504.002 Adjusting valve located on the machine shaft for regulating the flow of acetylene and compressed air Adjusting valve with vertical hand wheel and vertical valve cone Labelling Acetylene: red Compressed air: black

LINDOFLAMM thermal engineering. Tailored solutions for every heating application. 17 Ignition flame. Length of ignition flame (with hook, nozzle and adjusting valve) Connecting thread in. 600mm 3/8 LH 505.001 Safely igniting hand-operated and stationary burners Two-part brass ignition flame with adjusting valve Mixing principle: Acetylene with aspirated air With a brazed hook

18 LINDOFLAMM thermal engineering. Tailored solutions for every heating application. Spare parts. Acetylene/ compressed air replacement nozzle Coupling nut M16x1.5 O-ring for lance burner flange Socket spanners for nozzle assembly Replacement nozzle with cutting ring 1 506.001 Coupling nut for acetylene/ 1 506.002 compressed air nozzle Service package 1 10 5 2 1 506.003 Service package 2 20 10 4 1 506.004 Repairs to LINDOFLAMM special burners must only be carried by competent personnel, authorised by Linde AG. Linde AG is not liable for any damage resulting from unauthorised repairs or alterations carried out by the user or third parties without its approval.

LINDOFLAMM thermal engineering. Tailored solutions for every heating application. 19 All-round support. First-class services for LINDOFLAMM special burner applications. LINDOFLAMM special burner applications can be easily incorporated into customer production processes. Our all-round service package delivers a wide range of benefits for easy installation and operation. This extensive package comprises a wide range of services including: Integration management Installation service Burner optimisation Burner maintenance and service Targeted support For further information about LINDOFLAMM please contact your local AGA supplier.

AGA +46 8 706 95 00 www.aga.com 0414