Product Brief. specification. UV Module Solution. Description. Features and Benefits. Key Applications CMW-PS-C01. Table 1.

Similar documents
Preliminary specification

RoHS. Specification SAWW9H0A. 서식번호 : SSC-QP (Rev.00)

SURFACE MOUNT LED 405 nm, 1206 UV IL PACKAGE

Used as indicators of indicating the Degree, Functions, Positions etc, in electronic instruments

A214B/SUG/S400-X6 LAMP. Features. Description. Applications. Revision 1. Expired Period: Forever. LifecyclePhase: Low power consumption

ML520G55 FEATURES. Package: φ5.6mm TO-CAN PKG APPLICATION. Reverse voltage

SPECIFICATIONS. US0603YG LED Chip 0603 Yellow Green SWISSDIS. Swissdis AG Grasweg 7 CH-4911 Schwarzhäusern

SMT450. High Performance TOP LED

Recommendations/Comments for "IPC 1601" (Implementation subject to customer/supplier agreement)

SMD 2121 Black Frame MC-S2121BHA

Technical Data Sheet. Pb Free. Specification NB104 SSC. Customer. Rev. 03 July 서식번호 : SSC- QP (Rev.0.

PRODUCT SPECIFICATION

G155PU001S. Pigtailed 14-PIN DIL Laser Diode with TEC. FLMS Min. Typ. Max.

EVERLIGHT ELECTRONICS CO.,LTD.

ML60171C FEATURES. φ5.6mm TO-CAN PKG (with monitor PD) APPLICATION Motion sensor Printing. Reverse voltage (PD)

SPECIFICATIONS FOR REFOND SURFACE MOUNT LED

Technical Data Sheet 5mm Infrared LED, T-1

Technical Data Sheet 1.5mm Side Face Infrared LED

Metal, ceramic, plastic package products

Recommendations/Comments for "IPC 1601" (Implementation subject to customer/supplier agreement)

CLARA AC Crystal CLARA AC 50. LED-modules for downlight. A qualified solution to replace and exceed Halogen solutions in Downlights.

Specification MBT801-S

TSLC 6 UV LED 24v Strips

Flame Simulator User Manual. Publication Rev. A

ML562G84 APPLICATION. Display system. Symbol Parameter Conditions Ratings Unit. Pulse (Duty 40%)

Steril Air mobil. Owner s Manual. GENTRA Rıhtım cd. Yuva sk. No: ¾ Beyoğlu İstanbul Turkey Tel : Fax:

ML501P73 TYPE NAME. FEATURES High Output Power: 1.0W (Pulse) 0.5W (CW) High Efficiency: 1.0mW/mA (typ.) Visible Light: 638nm (typ.) 5.

33 Watt Low Voltage LED Fixture for Hazardous Location Lighting - Low Profile Linear Fixture - C1D2

PD100MF0MPx. Surface Mount Type, Opaque Resin Photodiode. PD100MF0MPx. Agency Approvals/Compliance. Features. Model Line-up.

Prizmatix UV Torch. User Manual

CATALOGUE LASER POINTERS

HFX Fiber Optic Component 50 Mbps, 650 nm LED

STRUCTURED LIGHT. LED Strobe Indicator ON = Light Active Green Indicator LED

ELLA ID. High CRI, High lm/w OptoDrive LED-module

PRODUCT SPECIFICATION

Instruction Manual E4 ChamberIR Heater

PRODUCT SPECIFICATION

Title: Laser Safety Effective Date: 9/91 Revision: 2/97 Number of Pages: 7

CM97-xxx-7x. Cooled 980nm Pump Laser Module. Product Datasheet. Features. Applications

Ultraviolet Lights on Daikin Applied Rooftop Systems and Rooftop Air Handlers

Technical Data Sheet 1.6mm Side Looking Phototransistor

UVDI-360. Get the Facts Straight on UV Disinfection. Room Sanitizer

LUXEON S. Philips Lumileds does not recommend staring directly into any LED lamp or luminaire. LUXEON S Photobiological Safety Report

Safety Manual Section 15 Radiation Safety

High Power COB LED. Features. Applications. ① Product line code: COB10W-C & COB10W-W. ② Product code base plate. ③ Chip code. ④ Emitting light colours

EN , EN , DALI 102/207, SELV Output, KS C 7655 Safety Certification Approved RoHS Compliant. Dim. Method

Stony Brook University Hospital Environmental Health & Safety Policy & Procedure Manual. EH&S 6-8 Original : 1/00 Revision Date: 3/16/15 Pages 6

VMS-3. Part Number: Ultraviolet Systems VMS-3. Installation, Operation & Maintenance

Laser Use at Subaru Telescope (NAOJ) Laser Safety Policy

Surface Mount 905 nm Pulsed Semiconductor Lasers High Power Laser-Diode Family for Commercial Range Finding

SHENZHEN LAMPLIC TECH CO., LTD UV LED SPOT CURING SYSTEM TECHNICAL MANUAL

UV measurements for medical applications using SiC photodiodes

PRODUCT SPECIFICATION

No. STSE-CC7186A <Cat.No > SPECIFICATIONS FOR NICHIA CHIP TYPE UV LED MODEL : NCSU034A(T) NICHIA CORPORATION -0-

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

LaserPlus Model LP-OA EDFA OPERATING MANUAL

INSTALLATION & MAINTENANCE

OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL

Instructions for Emperor Aquatics, Inc. s 16, 25, & 57 Watt Retro-Fit UV Sterilizer (for Savio s Skimmers)

ANTIBACTERIAL HAND VAC WITH UV LIGHT

Laser Safety Self-Audit Checklist

Reverse Package Infrared LED IR25-21C/TR8

Document No A9 Revised August Atlantic Ultraviolet Corporation

REGISTERED HANDBOOK. Document: ECN: Revision: C. MANUAL, O&M TrojanUVLogic TM System Systems Without Wiper AM, VM & TM Models

USER MANUAL. WDM-D15xx.xx. Single Wavelength Add/Drop Module for DWDM

Dust sensor SM-PWM-01A SPECIFICATION. Product Name: Dust Sensor Model No. : SM-PWM-01A 1 / 12

Surface Mount Ambient Light Sensor PTAS-P1F1708CH6. Features. Descriptions. Applications. Device Selection Guide

100W Explosion Proof Ultraviolet Portable LED Fixture - 365NM - EXP Cord Caps - 150ft Cord

Ref No: Date: September 30, 1994 ELECTRICAL AND ELECTRONIC EQUIPMENT NO. 2

, Backsuk-ri, Paju-eup, Paju-city, Gyeonggi-do, Korea TEL: FAX:

UV I UNIT030W / UV I UNIT055W

ULTRAMAX GOLD UMX REMOTE LAMP AIR DISINFECTION SYSTEMS w/ ODOR REDUCING TECHNOLOGY (PCO) OWNERS GUIDE

LUXEON Rebel. Philips Lumileds does not recommend staring directly into any LED lamp or luminaire. LUXEON Rebel Photobiological Safety Report

TEST REPORT IEC , 2 nd Edition Part 1: Equipment classification and requirements

Owner s Manual. Airgle Personal Air Purifier ( Model: AG25 )

UV Lamp and Quartz Sleeve Replacement/Maintenance

Application note. LCD Module. Precautions for LCM handling. LCM handling V 1.1

FagronLab NP-1 UV. Negative pressure workbench. User Manual

Inside your life! LG Innotek's innovative technologies will take you to a safe, convenient and enjoyable future. 7 th, May 2018

This slide presentation has been prepared for Temple University Health System and is intended only for use by it s faculty, staff and students.

FEBL8511_REFBOARD_Manual-01 ML FC. REFERENCE BOARD Manual for UV Sensor (QFN)

Radiation and Laser Safety

Model gffoz Process Ozone Sensor (In-Line)

SPECIFICATION OF ANALOG MEMS MICROPHONE. ( Ultra Mini Top Port ) MODEL NO. : F1-(A)MOE-C110T42-4CP

Erbium-Doped Fiber Amplifier (EDFA) - MW Series

Chemistry Instrumental Analysis Lecture 4. Chem 4631

Ultraviolet Systems UV-C 50 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

SPECIFICATIONS PARTICLE SENSOR KS-41B Higashimotomachi, Kokubunji, Tokyo , Japan

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

North Dakota State University Laser Safety

NX8601BF-AA. Data Sheet R08DS0109EJ0100 Rev.1.00 Apr 19, 2013 LASER DIODE DESCRIPTION FEATURES

High Lux Performance White LED MR16 Lamp

A measured step forward

PURPOSE OF THE PROCEDURE

Vertical Gel Systems-Dual CAT NO: EPS-V0011 & EPS-V0012

Real-time Monitoring Technology for Preservation Environment of Archives

Description. Applications Sensor development Methane Gas detection External modulation. DFB-1XXX-BF-XX-CW-Fx-Hx-N REV 004 1

SKLAR COATED SURGICAL INSTRUMENTS RECOMMENDED CARE & CLEANING INSTRUCTIONS

Technical Data Sheet 5mm Phototransistor T-1

1. Table of Contents VisiJet Materials Overview Disclaimer Ispropyl Alcohol (IPA) and Polypropylene Glycol

Transcription:

UV Module Solution specification Product Brief Description is disinfection Module with UV LED mounted on the Metal PCB. It can be easily connected electrically by putting in the connector. UV module is suitably designed for water and surface sterilization. Features and Benefits Deep ultraviolet LED Low thermal resistance Simple BOM Miniaturization Lead Free Product Key Applications Disinfection Table 1. Product Product type Input Voltage[Vin] Φe [mw] Min Wp [nm] Max Remark 12 3.0 270 280 Constant Voltage * Above data base on DC Power Supply Refer to the below test condition. 1

Table of Contents Index Product Brief Table of Contents Performance Characteristics Part list Mechanical Dimensions Packing Precaution for Use Revision History 2

Performance Characteristics Table 2. Electro Optical Characteristics, T a =25 Parameter Symbol Value Min. Typ. Max. Unit Peak wavelength [1] λp 270 275 280 nm Input Voltage V in 12 Vdc Power Consumption P 0.36 W Radiant Flux [2] Φe [3] 3.0 mw Spectrum Half Width Δλ 10 nm Weight g 10.0± 0.1 g Notes : (1) Peak Wavelength Measurement tolerance : ±3nm (2) Radiant Flux Measurement tolerance : ±10% (3) Φe is the Total Radiant Flux as measured with an integrated sphere. (4) All measurements were made under the standardized environment of Seoulviosys 3

Part list Table 3. Part List No Product type Item Specification Quantity MODULE GUARD (Material : PP) 1 INNER GUARD (Material : PP) 1 OUTER GUARD (Material : PP) 1 LED GUARD (Material : PP) 1 1 QUARTZ GLASS 1 SILICONE ORING_1 1 SILICONE ORING_2 1 LED PCB ASSY _(275nm AAP PKG ) 1 Wire_200mm 1 4

Mechanical Dimensions Module Guard Outer Guard Notes : - Dimensions of the indicated maximum value, and to allow a tolerance : ±0.5 [mm] 5

Mechanical Dimensions 6

Packing Pack the tray in a box *32ea UV LED modules packed per tray BOX *1BOX : 32ea per tray x 20Trays = 640ea *TOTAL : 640ea per 1BOX * If it is not a full box, apply the buffer material to fix the product * UV LED Module 20ea Trays and additional 1 dummy tray each up of box * Labeling Tapping Tapping * Tapping 21ea Trays. 7

Precaution for Use 1) Storage To avoid moisture penetration, we recommend storing UV Module in a dry box with a desiccant. The recommended temperature and Relative humidity are between 5 and 30 and below 50% respectively. UV Module must be stored properly to maintain the device. If the UV Module is stored for 3 months or more after being shipped from SVC, a sealed container with a nitrogen atmosphere should be used for storage. Replace the remained UV Module into the moisture-proof bag and reseal the bag after work to avoid those UV Module being exposed to moisture. Prolonged exposure to moisture can adversely affect the proper functioning of the UV Module. 2) Handling Precautions VOCs (Volatile organic compounds) emitted from materials used in the construction of fixtures can penetrate products and discolor them when exposed to heat and photonic energy. The result can be a significant loss of light output from the fixture. Knowledge of the properties of the materials selected to be used in the construction of fixtures can help prevent these issues. In case of attaching UV Module, do not use adhesives that outgas organic vapor. Please do not use(or storage) together with the materials containing Sulfur. Do not use inflammable material nearby the products. Do not touch the products with wet hand Do not fix or remodel the products. Do not drop the machine, or give strong impact on the products. The UV Module is encapsulated with special material for the highest flux efficiency. So it needs to be handled carefully as below - Avoid touching quartz glass parts especially with sharp tools such as Tweezers - Avoid leaving fingerprints cover parts. - UV Module will attract dust so use covered containers for storage. 8

Precaution for Use 3) Safety for eyes and skin The Products emit high intensity ultraviolet light which can make your eyes and skin harmful, 4) Cleaning So do not look directly into the UV light and wear protective equipment during operation. After assembly the product, empty the water and then wipe the UV Module with a dry towel. 5) Others Be sure to turn On / Off after module is connected. When connecting the module in the power on state, LED can be damaged by the influence of the inrush voltage / current. The driving circuit must be designed to allow forward voltage only when it is ON or OFF. If the reverse voltage is applied to UV Module, migration can be generated resulting in LED damage. Do not handle this product with acid or sulfur material in sealed space Please handle using equipment that prevents static electricity. Do not touch unless ESD protection is used. Ionizer, grounding and keeping appropriate humidity are necessary for work environment. The appearance and specifications of the product may be modified for improvement without notice 9

Revision History Revision Date Page Remarks 00 01. Dec. 2017 All The first edition 10