EVAPACK SERIES EVAPORATIVE PAD ADIABATIC HUMIDIFIERS

Similar documents
EvaPack SERIES EVAPORATIVE PAD ADIABATIC HUMIDIFIERS

INTELLIGENT SOLUTIONS FOR ADIABATIC COOLING IN DATA CENTERS

Custom modular design to fit any application

CONDAIR ME. In-duct evaporative humidifier and cooler Very low energy operation. Humidification and Evaporative Cooling

Media Pad Evaporative Air Humidifiers. HEF2 Series, for Air Handling Units HEF3 Series, for Air Ducted Systems

HIGH-PRESSURE ATOMIZING SYSTEM. Humidification and adiabatic cooling. Energy efficient Reduces cooling load Multiple zone capabilities

EVAPORATIVE COOLING AND HUMIDIFICATION. High-Pressure System Wetted Media System

Up to 10 zones. Spray directly into the space for high ceiling applications (approximately 30ft/9m)

Atomizing Nozzle Humidifiers. Designed for Air Handling Systems, and Manufacturers, Processors and Distributors of Humidity Sensitive Products.

Optimize Evaporative Cooler

High-Pressure Atomizing System

EVAPORATIVE COOLING AND HUMIDIFICATION. High-Pressure System Wetted Media System

PRESSURE FOG HIGH ATOMIZING HUMIDIFICATION SYSTEM

Steam Injection Humidifiers for use with steam boilers PRODUCT CATALOG

Fans Air handling units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans Air Humidifiers For DV Air Handling Units

humifog Pressurized water humidifi ers

Armstrong Cool-Fog Systems

Für Compacting alle Einsatzgebiete. Raumlufttechnik. High Pressure Humidifier and Airwasher Type HPH. Power Screw Type CPS. der dischargeoffinedust

High Pressure Fog System

Adsolair 56/58. Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system

Saving Energy With Evaporative Media

Evaporative Humidifier/Cooler FA6 for AHU s Technical manual FA6. HC/MMA/TGB /10 pdf SOS ReklamStudio

Steam Injection Humidifiers for use with steam boilers PR0DUCT CATALOG

LTG High Pressure Humidifier and Airwasher

Performance Rating of Commercial and Industrial Humidifiers

Colt CoolStream Adiabatic Cooling & Ventilation System

HumidiPack,HumidiPackPlus and HumidiPackPlus CF Steam Humidifier Systems

.4 Section Ductwork Low Pressure Metallic to 500 Pa..3 ANSI/ARI 640 Commercial and Industrial Humidifiers.

2003 METAL FORM MFG. FORM NO: PCIOM/03

mc multizone simple and robust, ideal for large industrial environments

GS Series. Gas Steam Humidifiers. Designed for air handling systems and for areas requiring individual humidification control

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY

S.A. Klein and G.F. Nellis Cambridge University Press, 2011

"ER" Series Electric Humidifier

Article Energy Saving Benefits of Adiabatic Humidification in the Air Conditioning Systems of Semiconductor Cleanrooms

Humidity matters! CAREL solutions for your humidification needs. carel.com. air humidification systems. isothermal and adiabathic humidification

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

ADVANCE TECHNOLOGIES FOR ADIABATIC COOLING AND HUMIDIFICATION Nortec Humidity, Inc. Fred Valentini Direct Room Systems Regional Manager Randall

Development of a Psychrometric Test Chamber. Michael J. Swedish. Associate Professor Mechanical Engineering Department Milwaukee School of Engineering

Adconair 76. Comfort air conditioning unit with counterflow plate heat exchanger. AIR VOLUME FLOW: 2,600 23,600 m³/h

Water atomiser through compressed air

EVAPORATIVE AIR-COOLING EQUIPMENT

A SYSTEM FOR HIGH-PERFORMANCE HUMIDIFICATION

HEF2 Series. Evaporative Humidifiers for Air Handling Units (A.H.U.) Installation and maintenance manual

Steam humidification: Reducing energy use, airstream heat gain, and condensate production

Steam Injection. Humidification system

Reducing energy use, airstream heat gain, and condensate production

For an ideal gas mixture, Dalton s law states that the sum of the partial pressures of the individual components is equal to the total pressure.

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

Reducing energy use, airstream heat gain, and condensate production

DVU-HP. Integrated Reversible Heat Pump System

2002 METAL FORM MFG. Form No: CCIOM/03

CONDAIR EL. Electrode boiler steam humidifier Easy maintenance with replaceable cylinders. Humidification and Evaporative Cooling

Cool, Clean and Comfortable Nortec HP-Series. Adiabatic In-Duct High Pressure Humidification System... Simply Awesome

TrilliumSeries Condenser 1 TRILLIUMSERIES CONDENSER 10 ECOFLEX CONTROLS 11 SELECTION AND PAYBACK ANALYSIS SOFTWARE 3 BENEFITS 8 MODES OF OPERATION

Colt CoolStream Evaporative Cooling & Ventilation System

Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans. Geniox.

Air Handling Units. Real HVACR people who understand your needs.

UNIT 1 AIR CONDITIONING 1. Write the various psychometric processes? Explain any four processes with neat sketches?

ME Mechanical Engineering Systems Laboratory. Experiment 3 - Mass and Energy Balances in Psychrometric Processes

DX Units. Ranging from 15 to 750 tons and 1,000 to 300,000+ CFM

Chapter 8 Balances on Nonreactive Processes PSYCHROMETRIC CHART

ORBIT WING THE BENEFITS SUMMARISED A COMPARISON. MICRO DROP duct humidifier Additional standards:

Chapter 14 GAS VAPOR MIXTURES AND AIR-CONDITIONING

AND AIR-CONDITIONING. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University

Air Handling Units. Geniox. Quick guide

DIGITAL-FLO SEMI-INSTANTANEOUS VERTICAL HOT WATER

HumidiClean Series HC-4000 Humidifier

Humidification Systems Product Guide

Comfort and health-indoor air quality

Flexible and efficient: Close Climate Control for IT equipment

PART 1 - GENERAL 1.1 WORK INCLUDED

Presenters. Brett Alexander. Mihir Kalyani. Troy Reineck

Reducing energy use, airstream heat gain, and condensate production

CE311 Fall 2016 Mid-Term Exam 1

Easdale International INFINITY

1.3 REFERENCES A. ANSI/NFPA 70 - National Electrical Code. B. ARI Commercial and Industrial Humidifiers.

Air-Handling System Cooling Options

Fundamentals of Psychrometrics. By James L. Murphy, Colorado Building Environments Sales Engineer

T1/B1 OPTIONAL ASEPSIS HYGIENIC AIR HANDLING UNITS. Fully washable & free cold bridge design for food and low temperature applications

air humidification systems adiabatic humidification humifog multizone high pressure atomised water humidifier carel.com

THE SIX STEPS OF HUMIDIFICATION DESIGN

Custom Air Handler Solutions Custom Units to Meet Your Unique Design Needs

The Basics - B Practical Psychrometrics. Jerry Cohen President Jacco & Assoc.

GEA Air Handling Units Modular configuration. Integrated refrigeration with optimized energy efficiency GEA CAIRplus.

LQQA Humidifier, for circulated water

INTELLIGENT HUMIDIFICATION. Two adiabatic humidification methods intelligently combined Condair DL. Humidification and evaporative cooling

Theoretical Performance Analysis Of Direct Evaporative Cooler In Hot And Dry Climates

Humidifier CERTO. How today s room humidifiers work

CONDAIR RS. Resistive steam humidifier With advanced scale management. Humidification and Evaporative Cooling

Best Humidifier Guide. Nortec s Guide to the Best in Humidification. Humidification and Evaporative Cooling

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

TOPAZ ADIABATIC COOLER

Chapter 14, Problem 27.

Double Intelligence Two adiabatic humidification methods intelligently combined. Humidification and Evaporative Cooling. humidity.

Cleanroom systems. Supply air ceiling and recirculated air ceiling OP. for operating rooms with low-turbulence displacement flow

Air-Handling System Cooling Options

HUMIDIFIERS EXTRAORDINAIRE

Greenhouse Temperature Management

The Growing Viability of UV LED for Wide Web Coating Applications. Tuesday, October 11, 2016

Transcription:

EVAPACK SERIES EVAPORATIVE PAD ADIABATIC HUMIDIFIERS

How the EVAPACK Series Works Simple, natural and efficient process Armstrong EVAPACK Series converts ordinary tap water to water vapor using an adiabatic process. Dry air passes through a corrugated bank of wetted cells media made from non-organic wet fibers. EVAPACK series uses the sensible air heat to evaporate the water. The air is cooled and humidified. Adiabatic process into psychrometric chart Usually they are two usual psychrometric design processes for evaporative humidification. Sensible heating: red horizontal lines Evaporative humidification: blue oblique lines Heating + humidification (line A-B-C). Pre-heating + humidification + post heating (line A-D-E-C). 80 90 100 30 Hot Dry Air Evaporative humidification Evaporative cooling Water Reserve 30 0,94 Cool Moist Air Evaporative Pad 30 28 26 24 22 120 110 70 2 20 20 30 40 10 0 E 10 60 1 20 1 0,84 C 90% 20 80% 70% 0,86 60% 0% 40% 30% 0,88 20% 0,90 18 16 14 12 10 8 6 100 90 80 70 A 0,78 0 0,80 0,82 D B 4 2 60 0 10 20 30 40 0 Both processes have humidity ratio (Δx) increase : from Xin (A) to Xout (C). The Saturation Efficiency (ŋ) or Cooling Efficiency is expressed in % and corresponds to the ratio between the entering dry bulb temperature and exiting dry bulb temperature over the wet bulb depression: ŋ = Real cooling/ Ideal cooling = (T in - T out ) / (T in - T wb ) with: T in is the inlet air dry bulb temperature, T out is the outlet air dry bulb temperature, T wb is the wet bulb temperature. For the humidification process B-C: the pad efficiency is smaller, and its thickness is thinner. For the humidification process D-E: the pad efficiency is higher, and its thickness is bigger. Typical configurations Direct evaporative humidification adds humidity to the supply air. Heating + humidification Pre-heating + humidification + post heating 2 North America Latin America India Europe / Middle East / Africa China Pacific Rim

EVAPACK Series Features and Benefits Plug and Humidify Easy and fast installation The EVAPACK humidifier water connections are on the side. Installation is quick, simple, and easy. Compact design with a maximum footprint of 600 mm. EVAPACK works with different type of water: potable water, reverse osmosis or soft water. Draining and over flow connections: 40 mm. Low and easy maintenance The EVAPACK humidifier cassettes are accessible by the side or by the front for big sizes. This reduces the requested replacement space. The cassette maintenance is made in seconds. EVAPACK humidifier water pump, water level detector, manual gate valves are on the service side, easily accessible for a simplified maintenance. Easy cleaning All EVAPACK elements are easy to disassemble, to clean and to reassemble. Customized Design EVAPACK humidifier is available for air handling units or ducts applications. Dimensions are customized according to your applications. Tailor made sizing. From approximately 0.36 m² to 9.00 m² in one piece assembly. Multiple EVAPACK humidifiers can be combined for larger sections. Efficient Low energy consumption EVAPACK humidifiers use the heat present in the air for humidifying and cooling. Optimized water contact surface EVAPACK has been designed to get the highest air/water contact surface. Up to 12% more than traditional evaporative pads. High efficiency and low pressure drop EVAPACK has been designed to maximize the efficiency and minimize pressure drop. North America Latin America India Europe / Middle East / Africa China Pacific Rim 3

EVAPACK Direct Water Series configuration and components Direct water configuration (DW) EVAPACK is supplied with the following standard components: Water basin with draining and overflow piping, EVAPACK evaporative cassettes (composed of EVAPACK evaporative pad and cassette frames in stainless steel 304), Side and top frames in stainless 304, Irrigation piping, Dispersion manifold(s) with calibrated orifices, Manual adjustment gate valve(s). 4 4 1 3 3 Options for DW configuration High efficiency integral droplet separator in PP material (requested for VDI 6022 hygienic configuration), Solenoid inlet water valve, Filling water pretreatment by U.V. Lamp with 0μm and μm water filters, Air relative humidity sensor, Air temperature sensor, Multiple stage control with solenoid valves (up to stage control), Water level detector (high water level Alarm). 6 2 Note: for electrical options our EVAPACK control pannel is recommended. Operation sequences A. Water enters from the water supply (1) and arrives to the dispersion manifold (4). The water flow is adjusted with a manual gate valve (3). B. The calibrated orifices deliver the water evenly over each media pad (). C. Dry air passes through a corrugated bank of wetted cells media (). Air is cooled and humidified. D. The excess water washes the EVAPACK evaporative pad and is eliminated (with minerals) from the water basin (2) through the draining connection (6). This DW configuration is recommended with high hardness supplied water (to increase the pad life time) or with reverse osmosis water (to reduce the RO water consumption). (For any additional information, please consult EVAPACK I.O.M. 42). 4 North America Latin America India Europe / Middle East / Africa China Pacific Rim

EVAPACK Recirculated Water Series configuration and components Recirculated water configuration (RW) EVAPACK is supplied with the following standard components: Water basin with draining and overflow piping, EVAPACK evaporative cassettes (composed of EVAPACK evaporative pad and cassette frames in stainless steel 304), Side and top frames in stainless 304, Irrigation piping, Dispersion manifold(s), Water pump, Manual adjustment gate valve(s), Water draining valve, Solenoid water filling valve, Water level sensor. 9 8 1 3 6 7 4 2 6 4 Note: All the electrical devices need our EVAPACK control panel to be used. Options for RW configuration High efficiency integral droplet separator in PP material (requested for VDI 6022 hygienic configuration), Filling water pretreatment by U.V. Lamp with 0μm and μm water filters, Water high temperature alarm, Air relative humidity sensor, Air temperature sensor, Multiple stage control with solenoid valves (up to 4 stage control), Water conductivity sensor. Operation sequences A. Water enters into the basin passing through the filling valve (1). The water level detector (7) controls the basin (2) filling, the pump (3) startingup and the fill valve opening. B. The recirculation water pump (3) supplies water to the different dispersion manifolds (). The water flow of each cassette (6) is adjusted with a manual gate valve (4).Calibrated orifices deliver the water evenly over each media pad (6). C. Dry air passes through a corrugated bank of wetted cells media (6), is cooled and humidified. D. The excess water washes the evaporative pad and falls (with minerals) into the water tank. E. The excess of minerals is drained by the draining valve minimizing the water consumption and the media scaling. This configuration is recommended when the available supplied water has a low or medium hardness. (For any additional information, please consult EVAPACK I.O.M. 42). North America Latin America India Europe / Middle East / Africa China Pacific Rim

EVAPACK Series model number MODEL NUMBER EVA - 1 - A/D xx Dw/Rw wwww hhhh ttt 0/1 R/L Service position R: right hand L: left hand Installation A: for air handling unit D: for duct Modular Configuration 10 20 Droplet separator 0: without droplet separator 1: with droplet separator Pad Thickness in mm Height in mm 11 21 Water System Dw: Direct water Rw: Recirculated water Width in mm EVAPACK series selection data Maximum width of the installation section Maximum height of the installation section Process airflow Inlet air conditions Requested outlet air conditions Application Maximum acceptable pressure drop 6 North America Latin America India Europe / Middle East / Africa China Pacific Rim

EVAPACK Evaporative pad The EVAPACK evaporative pad is an inorganic pad made of fiberglass sheets. High degree of wetting Special impregnated glass fibre material that allows for high moisture absorptive capability, ensuring continuous humidification. Rigid The media has a corrugated and compact structure. No rigidity loss. No fiber loss in the air flow. Safe None harmful substances. Complies the Directive Restriction of Certain Hazardous Substances (RoHS) 2011/6/UE (2002/9/CE). Hygienic Fulfils the requirements from the VDI 6022, Part 1 (04/2006) in microbial inertness and is suitable for use in HVAC-systems relating to this examination of microbial inertness. Fireproof Non-combustible Euro Class A1 according to EN ISO 1716:2011 and UNE EN ISO 1182:2011. Versatile EVAPACK evaporative pad accepts any potable water, soft water and reverse osmosis water. It can be used in all industrial and comfort applications. Free of odor from chemical and organics. Efficient The EVAPACK evaporative corrugation flute angle configuration has been designed to maximize the efficiency and minimize pressure drop. EVAPACK media pad performance charts based of the pad thickness Optimal Saturation Very low pressure drop (%) 100 9 90 Efficiency or Cooling effectiveness in % 200* (Pa) 200 190 180 170 160 10 Pressure drop in Pa 200* 8 80 10* 140 130 120 10* 110 7 100 70 100* 90 80 100* 70 6 60 0 60 40 30 20 10 0 1 1, 2 2, 3 3, 4 4, 0 1 1, 2 2, 3 3, 4 4, Air Front Velocity in m/s Air Front Velocity in m/s Droplet separator recommended Droplet separator necessary Droplet separator recommended Droplet separator necessary (*) maximal air front velocity recommended: 4. m/s. (*) maximal air front velocity recommended: 4. m/s. Remark: Other EVAPACK pad thicknesses are available, please consult Armstrong or your local representative. North America Latin America India Europe / Middle East / Africa China Pacific Rim 7

EVAPACK Control Basic control for RW configuration system Water pump Pump is protected against running dry according to DIN EN 1303-6.8.3.3 The pump has a thermic protection which can switch off the pump in case of overheating and gives a alarm signal to the control panel. It is also protected by the water level detector. Water level detector Two water control levels: 1 - The low water level: When the water level is below the low level, the pump is stopped. 2 - The high water level: When the water reaches the high level, the filling valve is closed. Drain Valve The control panel can switch on/off the drain valve. The drain valve controls basin emptying and the water deconcentration (or bleed-off). The deconcentration cycles can be adjusted by timer or by evaporated volume method. Basic control for RW configuration system. Multiple stages control With a RH sensor and solenoid valve(s), the EVAPACK control panel can adjust the water distribution on the pad cassettes. Up to 4 stage control. Stages watering control with by-pass damper With a RH sensor and solenoid valve(s), the EVAPACK control panel can adjust the water distribution on the pad cassettes and a proportional motorized damper. Multiple stages control for RW configuration system. Other optional controls Filling water pretreatment by U.V. Lamp with 0μm and μm water filters, Air relative humidity sensor, Air temperature sensor, Water temperature sensor, Water conductivity sensor. Multiple stages control for RW configuration system with by-pass damper. 8 North America Latin America India Europe / Middle East / Africa China Pacific Rim

EVAPACK Series certifications Safe Any harmful substances. Complies the Directive Restriction of Certain Hazardous Substances (RoHS) 2011/6/UE (2002/9/CE). Based on independent tests carried out by SGS Consumer Testing Services (IAS accredited). Safe No fiber loss in the air flow from EVAPACK evaporative pad. Based on independent tests carried out by SP Technical Research Institute of Sweden. Hygienic All the non-metallic parts fulfils the requirements from the VDI 6022, Part 1 (04/2006) in microbial inertness and is suitable for use in HVACsystems. Based on EN ISO 846 independent tests carried out by IHL BERLIN Institute for Hygiene. ILH BERLIN INSTITUT FÜR LUFHYGIENE Fireproof EVAPACK evaporative pad is non-combustible according to Euro Class A1. Based on EN ISO 1716:2011 and UNE EN ISO 1182:2011 independent tests carried out by Applus+ Laboratories. Designed according to VDI 6022 Hygienic standards. North America Latin America India Europe / Middle East / Africa China Pacific Rim 9

Notes 10 North America Latin America India Europe / Middle East / Africa China Pacific Rim

Notes North America Latin America India Europe / Middle East / Africa China Pacific Rim 11

INTELLIGENT SOLUTIONS IN STEAM, AIR, AND HOT WATER Armstrong International North America Latin America India Europe / Middle East / Africa China Pacific Rim Armstrong International Bulletin 99C-EN Printed in Europe - 06/17