TECH SHEET - DO NOT DISCARD PAGE 1 COMPONENT TERMINAL TEST CONNECTOR P5-1 P5-3 APPLIANCE MANGER P2-6 K9 WARM DRAWER RELAY K3 BAKE IGNITER RELAY T3-3

Similar documents
TECH SHEET - DO NOT DISCARD PAGE 1 COMPONENT TERMINAL TEST CONNECTOR P5-1 P5-3 P2-2 V APPLIANCE MANAGER P2-7 P2-8 P1-7 P1-5 P1-4

WARNING FOR SERVICE TECHNICIAN S USE ONLY

PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY

FOR SERVICE TECHNICIAN S USE ONLY

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

FOR SERVICE TECHNICIAN S USE ONLY

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

KAC - 57 TECHNICAL EDUCATION JOB AID W & 30 Built-In Single and Double Wall Ovens. Multimedia Enhanced

Dacor Technical Service

NOTICE . SAFE SERVICING PRACTICES. Electric Wall Oven with Electronic Oven Control

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires it.

KITCHENAID CONSUMER SERVICES Technical Training Department

SERVICE MANUAL. for Thermador Professional Series Built-in Wall Ovens. Models: PO301, POD301, PO302, POD302, PODC302, POM301, POMW301

TECH SHEET DO NOT DISCARD PAGE 1. If unsuccessful entry into diagnostic mode, actions can be taken for specific indications:

Products documentation (REVISION DATE: 03/10/2011) OMFP6010 (60cm PIROLITIC OVEN)

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

C Series Oven Training Program

WFR 2460 Service Tips -- Test Program

Technical Seminar HL-BD82S. Electric Built-In Oven. Panasonic Canada 2013

MSPA-MP METAPACK SERVICE MANUAL. Visual step-by-step guide to easily identify & correct technical problems! Gecko Electronics Inc.

Installation Instructions

2 PREPARE THE OPENING

FOR SERVICE TECHNICIAN ONLY DO NOT REMOVE OR DESTROY WARNING

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power before servicing, unless testing requires power.

DIAGNOSTIC GUIDE DISPLAY FAULT/ERROR CODES E1 THERMISTOR OPEN IMPORTANT. Activating the Diagnostic Test Mode. Test Mode Functionality

PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY

Hoshizaki America, Inc.

Service. Electric Slide-In Range

GE JB400 Steam Clean Range. Range Models: JB400DP1WW JB400DP1BB JB400SPSS

OVEN PARTS For Models: KEMS378SBL05, KEMS378SWH05, KEMS378SSS05 (Black) (White) (Stainless)

! CAUTION All safety information must be followed as provided in Service Manual ! WARNING

DIAGNOSTIC GUIDE LESS DRY TEST

Fast Track Troubleshooting

Electric Slide-In Range JES8750BA* JES8850BA* JES8850BC* JES9750BA* JES9800BA* JES9860BA* JES9860BC* JES9900BA* JES9900BC*

SERVICE DATA SHEET (9704) Rev. D

Ilnstallat!on. nstruct=ons. Before You Begin. Parts Included. Tools Needed. Built-In Wall Oven with Microwave ATTENTION INSTALLER

COOKTOP, BURNER AND GRATE PARTS For Model: JGRP548WP00 (Stainless)

! CAUTION. All safety information must be followed as provided in Service Manual ! WARNING

30" BUILT-IN COMBINATION MICROWAVE WALL OVEN Models:

OVEN PARTS For Models:KEMS308SBL05, KEMS308SWH05, KEMS308SSS05 (Black) (White) (Stainless)

TECH SHEET - DO NOT DISCARD PAGE

This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used by those not properly qualified.

Model OD302 Model OS302 MODELS A

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

FOR SERVICE TECHNICIAN ONLY DO NOT REMOVE OR DESTROY

DIAGNOSTIC GUIDE DIAGNOSTIC TEST DISPLAY FAULT/ERROR CODES IMPORTANT. Activating the Diagnostic Test Mode. Before servicing, check the following:

TECH SHEET - DO NOT DISCARD PAGE 1 DIAGNOSTIC GUIDE

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

TABLE OF CONTENTS ELECTRIC BUILT-IN OVEN. Model No. HL-BD82S. Canada

Installation Instructions Wall Ovens

S Series Ovens. Thermador Field Service

Service Manual. Thermador Built-In Oven. for. Models: SMW272 B, SMW272S, SMW272W, SMW272P STOP TIME SELF CLEAN OVEN LIGHT COOK TIME BAKE OFF

WARNING. Electrical Shock Hazard FOR SERVICE TECHNICIAN ONLY DO NOT REMOVE OR DESTROY L WASHER. Pub # /18/10 GE

Yale Real Living Touchscreen Deadbolt Installation and Programming Instructions

Installation Instructions

FOR SERVICE TECHNICIAN S USE ONLY

FIREYE EPD260, EPD261, EPD270 PROGRAMMER MODULES

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

Attached is Supplement three for service manual We suggest you file this with your Manual for reference.

Manual Examination Table

NN-A750WB NN-A720MB NN-A770SB 27L WHITE SILVER STAINLESS United Kingdom

1998 DISHWASHERS Servicing and Troubleshooting

Operator s Manual. 68 Inch Digital Conveyor Pizza Ovens

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

Technical Service Guide

FOR SERVICE TECHNICIAN S USE ONLY

Technical Service Guide

FOR SERVICE TECHNICIAN S USE ONLY

Technical Service Guide

Installation Instructions 30 French Door Built-in Wall Ovens

Aprilaire Dehumidifier Troubleshooting Manual Models 1830 & 1850

TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY

Service. Electric Freestanding Range

DC50X2 Models 50 Pound Stacked Commercial Dryer. Troubleshooting,Fault Codes, and Schematics. Starting serial number Part # /13

Low Water Cutoff (LWCO) IQ Option Card p/n , for Hot Water Boilers

KM-24 MICROHOOD COMBINATION

DIAGNOSTIC GUIDE DAMP DRY TEST

Installation Instructions

TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY

Maytag Gemini Range Service Manual

1998 WHIRLPOOL POWER CLEAN FILTER DISHWASHERS

Inside Outside

EASY-WAVE Trash & Linen Chute System Installation

XIII Troubleshooting

Hoshizaki America, Inc.

STEAMPRO. Steam Generator Troubleshooting and Service Guide

Operator: Save these instructions for future use!

SLIDE IN RANGE FREE STANDING RANGE BASIC: FER710DRS MODEL: NE58F9710WS MODEL CODE: NE58F9710WS/AC. 1. Precaution

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to washer before servicing, unless testing requires power.

30" BUILT-IN ELECTRIC COMBINATION MICROWAVE WALL OVEN MODELS: WOC54EC0AB03 (Black) WOC54EC0AW03 (White) WOC54EC0AS03 (Stainless)

Heating elements BSH/series 700 -convection system- FULGOR. SpA ELETTRODOMESTICI

Dishwasher Cycle Chart Condensation Dry System

COOKTOP PARTS. For Models: YKESV908PS01, YKESV908PM01 (S.Steel) (Meteorite) Illus. Part No. No. DESCRIPTION

Installation Instructions

Yale Real Living Assure Lock Push Button Deadbolt Installation and Programming Instructions (YRD216)

The Information Contained in this Document is Proprietary and should only be used for Service or Training of Authorized Blodgett Servicers who will

Transcription:

ECH SHEE - DO O DISCARD PAGE 1 ARIG Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or electrical shock. OE: Schematic shows door latch switch in the COOK position with oven door open, oven off, halo element off and light on. ES COEC R/ COPOE ERIAL G COECIO (SPLICE) O COECIO LEGED O SOE ODELS I LIE COECIO P1-2 = COEC P1 POSIIO 2 GD G ULIPLE FUCIOS / CIRCUIR ECLOSED IHI Caution: Label all wires prior to disconnection when servicing controls. iring errors can cause improper and dangerous operation. Verify proper operation after servicing. P1 KEPAD USER IERFACE P2 P5-1 P5-3 APPLIACE AGER P2-1 V P2-2 V P2-5 AI OVE SES EA PROBE P2-6 RASFER P7-1 HERAL CUOFF HERAL S OPES 130 C (266 F) @110 C±3 C (230 F±6 F) P6 AR DRAER SES P2-7 P2-8 DO SICH P1-4 BU LACH SICH 4-2 K9 AR DRAER RELA 5-1 / / AR DRAER 850 K3 BAKE IGIER RELA 3-3 R/ 4-3 4-4 K1 BROIL IGIER RELA K4 COVECIO RIG RELA K2 HALO RELA 3-1 3-2 BU/ 3-4 HALO 1200 COVECIO RIG 1400 / SURFACE BURER IGIIO SICHES K8 OVE LIGH RELA K5 COVECIO FA RELA K6 COOLIG FA RELA K7 LACH O RELA R/ BU/ R/ BU R R/ OVE LIGH 15 OVE LIGH P8-6 R/ 15 P8-3 COVECIO FA 40 P8-4 COOLIG FA 33.8±10% LACH O 3 HERAL S CLOSES P8-5 BR @60 C±3 C (140 F±6 F) GAS VALVE ODULE BROIL SOLEOID COO BAKE SOLEOID DSI 10 9 8 7 6 5 4 3 2 1 J2 SURFACE IGIS J4 J3 GD BAKE BROIL G BR 4,852,544 4,974,804 5,008,516 5,064,998 5,138,137 5,142,125 5,175,413 5,185,047 5,321,229 5,349,162 5,378,874 5,382,552 SOFARE COPRIGHED. HIS PRODUC IS COVERED B OE E OF HE FOLLOIG PAES: U.S. PAE OS. 5,422,460 5,424,512 5,438,180 5,441,036 5,491,314 5,571,433 5,571,434 5,620,623 5,694,916 5,749,388 5,756,970 5,767,488 5,808,278 5,810,576 5,813,320 5,841,112 5,856,654 5,881,710 5,910,265 5,918,589 5,924,857 5,928,543 5,961,311 5,967,634 5,983,888 6,008,478 6,017,211 6,035,848 6,043,461 6,079,756 6,087,944 6,097,000 6,111,231 6,163,017 6,201,222 6,232,584 AD OHER PAES PEDIG. 6,263,782 6,349,717 6,363,971 6,375,150 6,392,204 6,394,081 6,403,929 6,437,294 6,509,551 6,545,251 6,570,136 6,614,006 6,663,009 6,666,676 6,693,262 6,698,417 6,698,923 6,700,101 6,722,356 6,734,403 6,784,404 6,841,761 6,870,138 6,904,969 6,930,287 6,935,330 F SERVICE ECHICIA S USE OL PAR O. 10112145A

PAGE 2 ECH SHEE - DO O DISCARD SRIP CIRCUIS BAKE, PREHEA, CLEA During Clean, Broil solenoid is active during first thirty minutes only, followed by activation of Bake solenoid for remainder of Clean cycle. he following individual circuits are for use in diagnosis, and are shown in the O position. Do not continue with the diagnosis of the appliance if a fuse is blown, a circuit breaker is tripped, or if there is less than a 120 VAC (115 VAC Canada) power supply at the wall outlet. P2-1 V AI OVE SES APPLIACE AAGER P2-2 V 4-3 K3 BAKE IGIER RELA K2 HALO RELA P2-5 P2-6 P1-4 3-3 3-4 BU EA PROBE DO SICH LACH SICH HALO 1200 / 4-4 K1 BROIL IGIER RELA K7 LACH O RELA 3-1 P8-5 BR LACH O 3 (F CLEA OL) BU/ R/ BU R GAS VALVE ODULE BROIL SOLEOID COO BAKE SOLEOID DSI 10 7 6 4 3 2 1 J2GD J4 BAKE J3 BROIL G BR BROIL 4-3 4-4 APPLIACE AAGER K2 HALO RELA K1 BROIL IGIER RELA P2-1 V AI OVE SES P2-2 3-4 3-1 V DO SICH BU/ BU HALO 1200 BROIL SOLEOID COO GAS VALVE ODULE / 10 7 4 3 J2 GD 2 J3 BROIL G BR COOLIG FA APPLIACE AAGER K6 COOLIG FA RELA P8-4 HERAL S CLOSES @60 C±3 C (140 F±6 F) COOLIG FA 33.8±10% SURFACE UI ypical SURFACE BURER IGIIO SICHES DSI 10 9 4 SURFACE IGIS J2 GD PAR O. 10112145A F SERVICE ECHICIA S USE OL

ECH SHEE - DO O DISCARD PAGE 3 SRIP CIRCUIS OVE LIGHS he following individual circuits are for use in diagnosis, and are shown in the O position. Do not continue with the diagnosis of the appliance if a fuse is blown, a circuit breaker is tripped, or if there is less than a 120 VAC (115 VAC Canada) power supply at the wall outlet. APPLIACE AAGER K8 OVE LIGH RELA P8-6 R/ DO SICH R/ OVE LIGH 15 R/ OVE LIGH 15 COVECIO BAKE eat probe is optional and not shown. 4-4 4-3 APPLIACE AAGER K4 COVECIO RIG RELA K5 COVECIO FA RELA K3 BAKE IGIER RELA P2-1 V P2-2 V 3-2 P8-3 3-3 R/ DO SICH COVECIO FA 40 R AI OVE SES COVECIO RIG 1400 COO BAKE SOLEOID GAS VALVE ODULE 10 6 4 2 1 J2 GD J4 BAKE G COVECIO ROAS eat probe is optional and not shown. 4-3 APPLIACE AAGER K2 HALO RELA K5 COVECIO FA RELA K3 BAKE IGIER RELA P2-1 V P2-2 V 3-4 P8-3 3-3 R/ DO SICH COVECIO FA 40 R AI OVE SES HALO 1200 COO BAKE SOLEOID / GAS VALVE ODULE 10 6 4 2 1 J2 GD J4 BAKE G COVECIO BROIL 4-3 4-4 APPLIACE AAGER K5 COVECIO FA RELA K2 HALO RELA K1 BROIL IGIER RELA P2-1 V P2-2 V P8-3 3-4 3-1 BU/ BU DSI 10 7 4 3 2 J2 GD J3 BROIL G BR AI OVE SES DO SICH COVECIO FA 40 HALO 1200 BROIL SOLEOID COO GAS VALVE ODULE / F SERVICE ECHICIA S USE OL PAR O. 10112145A

PAGE 4 ECH SHEE - DO O DISCARD SRIP CIRCUIS he following individual circuits are for use in diagnosis, and are shown in the O position. Do not continue with the diagnosis of the appliance if a fuse is blown, a circuit breaker is tripped, or if there is less than a 120 VAC (115 VAC Canada) power supply at the wall outlet. COL POER/ CLOCK KEPAD P1 USER IERFACE P2 P6 APPLIACE AAGER P7-1 HERAL CUOFF 130 C (266 F) HERAL S OPES @ 110 C±3 C (230 F±6 F) RASFER AR DRAER APPLIACE AAGER P2-7 P2-8 AR DRAER SES 4-2 K9 AR DRAER RELA 5-1 / / AR DRAER 850 / DISPLA CODES Before proceeding with any corrective action, perform the following steps to enter the Diagnostics mode: 1. o recall last failure code, if not displayed, press the Off key to place the range in an idle state. 2. Press the Off and Start keys in the following order: OFF, OFF, SAR. 3. Verify the error code displayed on the control by observing for longer than 1 minute. If the error returns, use the applicable procedure listed below for the actual error code that is displayed. F0 Default F1 Internal E0 E0 ESSAGE/DESCRIPIO SUGGESED CRECIVE ACIO PROCEDURE o failure REPLACE OVE USER IERFACE PROCEDURE: Before proceeding, perform steps 1 through 3 above chart to enter the Diagnostics mode. B. Replace the user interface. C. Replace all parts and panels before operating. D. Plug in range or reconnect power. E. Verify operation is normal. Go to step 1 and complete checks. F1 E1 REPLACE OVE APPLIACE AAGER Internal PROCEDURE: Before proceeding, perform steps 1 through 3 above chart to enter the Diagnostics mode. B. Replace the appliance manager. C. Replace all parts and panels before operating. D. Plug in range or reconnect power. E. Verify operation is normal.go to step 1 and complete checks. ESSAGE/DESCRIPIO SUGGESED CRECIVE ACIO PROCEDURE F2 E0 KEPAD DISCOECED Keypad E1 SUCK/SHED KE PROCEDURE: Before proceeding, perform steps 1 through 3 above chart to enter the Diagnostics mode. B. Check that the keypad is firmly connected. C. Replace all parts and panels before operating. D. Plug in range or reconnect power. E. Observe for longer than 1 minute. F. If error remains then go to step G. G. Unplug range or disconnect power. H. Replace keypad. I. Replace all parts and panels before operating. J. Plug in range or reconnect power. K. Observe for longer than 1 minute. L. If error remains then go to step.. Unplug range or disconnect power.. Replace cable between user interface and keypad. O. Replace all parts and panels before operating. P. Plug in range or reconnect power. Q. Observe for longer than one minute. R. If error remains, go to step S. S. Unplug range or disconnect power.. Replace user interface. U. Replace all parts and panels before operating. V. Plug in range or reconnect power.. Verify operation is normal. Go to step 1 and complete checks. PAR O. 10112145A F SERVICE ECHICIA S USE OL

ECH SHEE - DO O DISCARD PAGE 5 F3 Sensors E1 E2 ESSAGE/DESCRIPIO SUGGESED CRECIVE ACIO PROCEDURE AI SES OPE SHED LOER OVE SES OPE SHED ARIG DRAER SES OPE SHED EA PROBE SHED enter the Diagnostics mode. B. Open the console and make sure the indicated temperature sensor is plugged in. If it is not, plug it in to the connector and go to step I. If it is plugged in, go to step C. C. Check connector P2 on the appliance manager. ake sure it is plugged in and fully seated. If it is not, make the proper connection and go to step I. If it is already properly connected, go to step D. D. Visually inspect the wires between P2 on the appliance manager and the indicated temperature sensor. ake sure the wires are not cut or pinched. If the wires appear to be intact, unplug the P2 connector on the appliance manager. Go to step E. E. easure indicated temperature sensor resistance value (measure between appropriate P2 connector pins). For the following sensors, the resistance value should read: ain Oven Sensor Between 931 and 2869 Ω. (Approx. 1080 Ω at room temp.) Lower Oven Sensor Between 931 and 2869 Ω. (Approx. 1080 Ω at room temp.) arm Drawer Sensor Between 1,500 and 319,000 Ω. (Approx. 119,420 Ω at room temp.) eat Probe Sensor Between 1,300 and 103,000 Ω. (Approx. 59,000 Ω at room temp.) (Insert meat probe into meat probe jack located inside the oven cavity prior to reading resistance.) easure any P2 connector pin to chassis. Resistance value should read open. If it does not, replace sensor harness. Repeat step E. If the indicated temperature sensor does not meet these requirements, go to step F. If the temperature sensor does meet the requirements, go to step I. F. For AI, LOER and AR DRAER sensors: Replace appropriate temperature sensor. Repeat step E. If the requirements are not met, replace sensor harness. Repeat step E. If the requirements are still not met, go to step G. For EA PROBE sensor: Replace meat probe sensor. Repeat step E. If the requirements are not met, replace sensor harness. Repeat step E. If the requirements are still not met, replace the meat probe jack. Repeat step E. If the meat probe sensor is still not meeting the requirements, go to step G. G. Replace the appliance manager. Ensure all connectors are properly seated. H. Ensure all wiring connections are made. I. Replace all parts and panels before operating. J. Plug in range or reconnect power. K. Observe for longer than 1 minute. L. Initiate a bake cycle. Let the cycle run at least 1 minute. If no error returns, cancel the cycle. he problem has been repaired. If the error occurs again, restart the troubleshooting procedure at step A. ESSAGE/DESCRIPIO SUGGESED CRECIVE ACIO PROCEDURE F5 E0 DO AD LACH SICH DO O AGREE Inputs E1 DO LACH O OPERAIG enter the Diagnostics mode. O VERIF DO SICH: A. hile in Diagnostics, open the oven door. 1 should appear in the second clock digit from the left. Close the oven door. he clock digit should toggle to 0. If the digit did not toggle, go to step B. If the digit did not toggle after replacing the door switch, go to step D. If the digit did not toggle after replacing the door switch harness, go to step F. If the digit did toggle, door switch is operating correctly. B. Unplug range or disconnect power. C. Replace door switch. (If door switch is integral to the door latch motor assembly, replace the entire door latch motor assembly). Go to step H. E. Check integrity of all harness wires and connections between the appliance manager and the door switch. Ensure no shorted wires to chassis. If the wiring is bad, replace the door switch harness. Go to step H. If the wiring is good, go to step H. F. Unplug range or disconnect power. G. Replace appliance manager. Go to step H. H. Replace all parts and panels before operating. I. Plug in range or reconnect power. J. Enter the Diagnostics mode described in steps 1 through 3 above chart on page 4. Repeat step A. O VERIF DO LACH SICH / O ASSEBL: A. hile in Diagnostics, press the CLEA key to cycle the latch motor to the locked position. 1 should appear in the first clock digit from the left when locked. Press the CLEA key to cycle the latch motor to the unlocked position. he clock digit should toggle to 0. If the digit did not toggle, go to step B. If motor runs continuously, wait until motor reaches the unlocked position, open the door, press the OFF key, go to step B. If motor did not run, go to step H. If the digit did not toggle after replacing the door latch motor assembly, go to step D. If the digit did not toggle after replacing the door latch switch harness, go to step F. If the digit did toggle, door latch switch is operating correctly. B. Unplug range or disconnect power. C. Replace door latch motor assembly. Go to step K. E. Check integrity of all harness wires and connections between the appliance manager and the door latch switch. Ensure no shorted wires to chassis. If the wiring is bad, replace the door latch switch harness. Go to step K. If the wiring is good, go to step K. F. Unplug range or disconnect power. G. Replace appliance manager. Go to step K. H. Unplug range or disconnect power. I. Check integrity of latch mechanism from cam to latch pawl and door slot. Ensure that pawl aligns with the door slot. Correct any mechanical malfunction. J. Check continuity of the latch motor and of electrical connections between appliance manager P8 and motor. If continuity is present, replace appliance manager. Go to step K. K. Replace all parts and panels before operating. L. Plug in range or reconnect power.. Enter the Diagnostics mode described in steps 1 through 3 above chart on page 4. Repeat step A. F SERVICE ECHICIA S USE OL PAR O. 10112145A

PAGE 6 ECH SHEE - DO O DISCARD F6 E0 ESSAGE/DESCRIPIO SUGGESED CRECIVE ACIO PROCEDURE LOS COUICAIO enter the Diagnostics mode. B. Open the console and make sure the P6 connector on the appliance manager and the P2 connector on the user interface are fully inserted. If not, plug in connectors and go to step F. If fully plugged in, go to step C. C. Visually inspect all of the four wires between P6 on the appliance manager and P2 on the user interface. ake sure the wires are not cut or pinched. If the wires appear to be intact, perform a continuity check between Pin 4 of the appliance manager and Pin 4 of the user interface. Do the same for Pins 1, 2, and 5. Both of these checks should result in a reading of less than 5Ω. If either of these checks fail, go to step E. If these checks pass, reconnect P2, then go to step D. D. Replace the appliance manager. Ensure all connectors are properly seated; then go to step F. E. Replace the wiring harness (signal) and go to step F. F. Ensure all wiring connections are made. G. Replace all parts and panels before operating. H. Plug in range or reconnect power. I. Observe for longer than one minute. J. If the error does not appear, initiate a bake cycle. Let the cycle run at least one minute. If no error occurs, cancel the cycle. he problem has been repaired. If the error occurs again, restart the troubleshooting procedure at step A (except in step D replace the user interface if the appliance manager has already been replaced). ESSAGE/DESCRIPIO SUGGESED CRECIVE ACIO PROCEDURE F6 E1 COOK RAGE OVER EPERAURE E2 CLEA RAGE OVER EPERAURE (Continued) enter the Diagnostics mode. A. Press the BAKE key to cycle the Bake relay on and off. If the Bake relay does not turn on and off, go to step F. If the element or gas valve does not cycle with the relay, go to step D. If the element or gas valve did cycle on and off, go to step B. B. Press the BROIL key to cycle the Broil relay on and off. If the Broil relay does not turn on and off, go to step F. If the element or gas valve does not cycle with the relay, go to step D. If the element or gas valve did cycle on and off, go to step C. C. Press the COVEC BAKE key to cycle the convect bake relay on and off. If the Convect Bake relay does not turn on and off, go to step F. If the element does not cycle with the relay, go to step D. If the element did cycle on and off, go to step D. E. Check integrity of all harness wires and connections between the appliance manager and the electric elements. Ensure no shorted wires to chassis. GAS ODELS: Ensure all wiring and connections between the control and spark module, spark module and bake/broil gas valve are good. If the wiring is good, go to step K. ELECRIC ODELS: Ensure all wiring and connections between the appliance manager and elements and the appliance manager and the user interface are good. If the wiring connections are not intact, go to step J. If the wiring is good, go to step I. F. Unplug range or disconnect power. G. Replace the appliance manager. Go to step Q. H. Unplug range or disconnect power. I. Replace the display. Go to step Q. J. Replace the harness. Go to step Q. K. Replace spark module. L. Replace all parts and panels before operating.. Plug in range or reconnect power.. Enter the diagnostics mode described in steps 1 through 3 above chart on page 4. Press the BAKE key or the BROIL key to turn the Bake or Broil gas valve on and off. If the Bake or Broil valves will not turn off, go to step O. If the Bake or Broil valves will not turn off after being replaced, go to step H. If the Bake or Broil valves do turn off, go to step Q. O. Unplug range or disconnect power. P. Replace the Bake/Broil gas valve. Go to step L. Q. Replace all parts and panels before operating. R. Plug in range or reconnect power. S. Verify operation is normal. Go to step 1 and complete checks. PAR O. 10112145A F SERVICE ECHICIA S USE OL

ECH SHEE - DO O DISCARD PAGE 7 ESSAGE/DESCRIPIO SUGGESED CRECIVE ACIO PROCEDURE F6 E3 II OVE/AR DRAER OVER EPERAURE (Continued) enter Diagnostics mode. A. Press the arming Drawer O key, then the arming Drawer OFF key to cycle the arming Drawer relay on and off. If the arm Drawer relay does not turn on and off, go to step D. If the element does not cycle with the relay, go to step B. If the element does cycle with the relay, go to step B. B. Unplug range or disconnect power. C. Check the integrity of all harness wires, the connections between the appliance manager and the electric element, and the connections between the appliance manager and the user interface. If the wiring connections are not intact, go to step F. If the wiring is good, go to step G. E. Replace the appliance manager. Go to step H. F. Replace the harness. Go to step H. G. Replace the user interface. Go to step H. H. Replace all parts and panels before operating. I. Plug in range or reconnect power. J. Verify operation is normal. Go to step 1 and complete checks. ESSAGE/DESCRIPIO SUGGESED CRECIVE ACIO PROCEDURE F6 E4 USER IERFACE/APPLIACE AAGER ISACH (Continued) enter Diagnostics mode. ait 10 seconds. B. Plug in range or reconnect power. C. Enter into Diagnostics mode by pressing OFF, OFF, SAR. D. Press BAKE. Ensure Bake relay energizes by inspecting Bake element is active. E. Press BROIL one time for outer broil element. Ensure Outer Broil relay energizes by inspecting the Outer Broil element. F. Press BROIL again for Inner Broil element. Ensure Inner Broil relay energizes by inspecting the Inner Broil element. G. Press SELF CLEA to drive door latch to lock door. Press again to reset door latch to normal state. H. If all functions do not work properly, go to step L. I. If all functions are working, the Appliance anager and User Interface are working properly. J. Exit Diagnostics by pressing OFF. K. Press BAKE and ensure that the Bake relay energizes and the control enters the Bake Preheat. ait up to 60 seconds to ensure error has been resolved. If error returns, proceed to step L. L. Unplug range or disconnect power.. Remove covers for access to controls.. Replace the appliance manager. Ensure all connections are properly seated. O. Replace all parts and panels before operating. P. Plug in range or reconnect power. Q. Press BAKE and ensure that Bake relay energizes and the control enters into Bake/Preheat. ait up to 60 seconds to ensure error has been resolved. If error returns, go to step R. R. Unplug range or disconnect power. S. Replace the user interface. Ensure all connections are properly seated.. Replace all parts and panels before operating. U. Plug in range or reconnect power. V. Press BAKE and ensure the Bake relay energizes and the control enters into Bake/Preheat. ait up to 60 seconds to ensure error has been resolved.. Verify operation is normal. Go to step 1 and complete checks. F SERVICE ECHICIA S USE OL PAR O. 10112145A

PAGE 8 ECH SHEE - DO O DISCARD ESSAGE/DESCRIPIO SUGGESED CRECIVE ACIO PROCEDURE F6 E5 O CAVI SIZE COAD (Continued) PROCEDURE: Control should immediately power up in Cavity Size Select mode. Using key #6 (DO) and key #3 (UP) scroll through to locate the corresponding cavity size. Once located press the SAR key to accept the proper cavity size for the oven being programmed. Control should reinitialize to cavity size selected. If error returns at least 60 seconds after cavity size has been set, go to step A. B. Plug in range or reconnect power. C. Enter into Diagnostics mode by pressing OFF, OFF, SAR. Press #6 (DO) once ain Diagnostic screen appears. Screen should identify cavity size for oven being programmed. If this is incorrectly shown, press CLOCK to edit current programmed size. Press #6 (DO) to locate proper cavity size. Once located, press SAR to accept the new cavity size. Control will reset and initialize the new cavity size programmed. ait for 60 seconds to ensure error has been corrected. If error is corrected, go to step F. If error returns, go to step D. E. Replace user interface ensuring all connections are properly seated and go to step F. F. Replace all parts and panels before operating. G. Plug in range or reconnect power. H. Control may power up in Cavity Size Select mode. Set cavity size as outlined in step C by locating proper cavity size and pressing SAR once located. I. Verify operation is normal. Go to step 1 and complete checks. PAR O. 10112145A OE: his sheet contains important echnical Service Data. F SERVICE ECHICIA OL DO O REOVE DESRO PAR O. 10112145A F SERVICE ECHICIA S USE OL 11/06