Service Quick Guide SQG_CL_15/01_EN Indesit Company, Service Department Table - New Platform 2005 Electronic Refrigerators, combination and double-door 1 LED1 LED2 LED3 2 Table 1 In the case of the Led interface (fig.1 - fig.2), faults are displayed by combinations of Leds ( Table 1) Off Blinking Off Alight Off Alight Alight Blinking Off Off Alight Alight Off Blinking Alight Off Off Off Alight Blinking Alight Alight Alight Alight Blinking Blinking Alight Off Off Blinking Alight Blinking Blinking F20 Blinking Off Blinking Off Blinking Blinking F21 Alight Alight Blinking Blinking Blinking Off Blinking Alight Alight Blinking Blinking Blinking F23 Blinking Alight Blinking Alight Off Off F24 Off Alight Blinking Off Off Blinking F25 Alight Off Blinking Off Off Alight Blinking Off Alight Alight Alight Off 1/5
Table - New Platform 2005 Electronic Refrigerators, combination and double-door 3 4 LED5 LED3 LED4 F= N =XX LED1 LED2 5 2/5 F= Table 2 In the case of the Mid interface with Led arrays and buttons (fig.3), faults are displayed by combinations of Leds on the Freezer temperature bar ( Table 2). In the case of the Digit interface with segment display (fig.5) and Touch interface (fig.4) faults are shown by messages in the display segments. LED4 LED5 Alight Off Off Off Off Off Alight Off Off Off Alight Alight Off Off Off Off Off Alight Off Off Alight Off Alight Off Off Off Alight Alight Off Off Alight Alight Alight Off Off Off Off Off Alight Off Alight Off Off Alight Off Off Alight Off Alight Off Alight Alight Off Alight Off Off Off Alight Alight Off Alight Off Alight Alight Off F20 F21 F23 F24 F25 F28 N =XX LED4 LED5 Off Alight Alight Alight Off Alight Alight Alight Alight Off Off Off Off Off Alight Alight Off Off Off Alight Off Alight Off Off Alight Off Off Alight Off Alight Alight Off Alight Off Alight Off Alight Alight Off Alight Alight Alight Alight Off Alight Off Off Off Alight Alight Alight Off Off Alight Alight Off Alight Off Alight Alight Off Off Alight Alight Alight
Table - New Platform 2005 Electronic Refrigerators, combination and double-door 3/5 Compressor relay sticking Compressor relay open y power board Freezer fan unit does not run Electronic damper does not close/open Triac driving defrost heating element short-circuit No power draw of defrost heating element Incorrect switching of solenoid valve File setup error (EEPROM not programmed or faulty) NO-FROST Models: y ON/ OFF DAMPER STATIC Models with CCZ: SEC- ONDARY SOLENOID VALVE - Check for water leaks that may affect connector J1 causing the relative contacts to short; - Check motor terminal board (possible problems due to incorrect connection which may cause short-circuits); - Renew motor; - Check effi ciency of contacts on connector J1 on the PCB; - Check on wiring connector J1 between pins 3 and 2 for an impedance value that is compatible with the value given in the specifi c table. - Check that the compressor is not stopped due to overtemperature conditions (thermal cutout open) - Renew motor; - Check impedance on wiring connector J6 between pins 2 and 1 checking that the value is compatible with the value given in the relevant table; - Check correct connection of the freezer fan on the freezer compartment wiring junction box; - Renew freezer fan unit; - Check effi ciency of J3 connector contacts on PCB; - Check efficiency of connection of electronic damper at foam protected connector behind multifl ow; - Renew electronic damper; - Check condition by checking for impedance on wiring connector J6 pins 3 and 4; - Check connections of the defrost heating elements and possible short circuits on the freezer compartment wiring junction box; - Renew heating element. - Renew PCB - Check for continuity of the defrost heating element on pins 3 and 4 of connector J6, ensuring that the impedance value read is compatible with the value given in the relevant table; - Check for correct connection of the defrost heating element and the drip tray heating element on the freezer compartment wiring junction box; - Check the correct impedance value on the defrost heating element across the heating element terminals; - Check that the fuses have not blown; - Renew defrost heating element; - Check effi ciency of contacts on connector J8 on the PCB; - Check for impedance on wiring connector J8 pins 1 and 2 and ensure that the value is compatible with the value given in the relevant table; - Check correct switching of the solenoid valve With the compressor running, check that the solenoid valve switches when the refrigerator compartment is set to OFF. - Renew solenoid valve; - In the case of a production PCB, renew PCB and EEPROM; - In the case of replacement PCB and EEPROM, check correct insertion of EEPROM in PCB socket. NO-FROST Models: y ON/OFF DAMPER - Check effi ciency of contacts on connector J7 on the PCB; - Check efficiency of the damper connection to the connector inside the air duct in the variable temperature refrigerator compartment; - Renew ON/OFF damper; CCZ STATIC models with SECONDARY SOLENOID VALVE fault - Check effi ciency of contacts on connector J5 on PCB; - Check impedance on wiring connector J5 pins 1 and 2, ensuring that the value is compatible with the value given in the relevant table; - Check correct switching of the solenoid valve. With the compressor running, check that the solenoid valve switches when the variable temperature compartment is set to OFF. - Renew solenoid valve; Check
Table - New Platform 2005 Electronic Refrigerators, combination and double-door F20 4/5 Fridge fan driving Triac (Combi NF models) short-circuit No communication between display PCB and control PCB Fridge fan does not run (Combi NF models) y power board Multiflow heating element driving Triac short-circuit Fridge fan unit does not run (static models) Multiflow heating element fails to switch on (NO-FROST models) Vacuum pump does not work (Ever Fresh model) AQUA CARE 1 solenoid valve does not work (Aqua Care model) AQUA CARE 2 solenoid valve does not work Fridge lamp fails to switch on - Check efficiency of contacts on connector J6 on PCB; - Check condition by checking impedance on wiring connector J6 pins 1 and 2 - Check fridge fan connections inside refrigerator compartment; - Renew fridge fan. - Renew PCB For LED interface PCB: - Check continuity of connector J13 / LED PCB 5-way and 7-way connectors; - Renew display PCB; For Indesit digit interface PCB and Ariston LED interface PCB on appliances with CCZ and/or Ever Fresh System: - Check continuity of connector J13/ interface PCB 4-way connector; - Renew display PCB. For Touch interface PCB: - Check continuity of connector J13/interface PCB 4-way connector; - Check continuity of connector J13/connector inside cabinet control panel; - Check continuity of connector inside cabinet control panel / interface PCB 4-way connector; - Renew display PCB. - Check efficiency of contacts on connector J6 on PCB; - Check for continuity of the defrost heating element on connector J6 pins 1 and 2, ensuring that the impedance value read is compatible with the value given in the relevant table; - Check correct connection of the fridge fan; - Check correct impedance value of the fridge fan; - Renew fridge fan; - Check impedance on wiring connector J2 pins 3 and 1, ensuring that the value read is compatible with the value given in the relevant table; - Check for short-circuits on the Multiflow heating element inside the refrigerator compartment; - Renew Multiflow heating element; - Check for impedance on wiring connector J2 pins 3 and 1, ensuring that the value read is compatible with the value given in the relevant table; - Check correct connection of the fridge fan (of Multifl ow heating element) inside refrigerator compartment; - Renew fridge fan unit (Multiflow heating element); - Check efficiency of contacts on connector J4 on PCB; - Check impedance on wiring connector J4 pins 1 and 2, ensuring that the value read is compatible with the value given in the relevant table; - Renew vacuum pump or AQUA CARE 1 solenoid valve; - Check effi ciency of contacts on connector J10 on the PCB; - Check for continuity of the solenoid valve on pins 3 and 4 of connector J10, ensuring that the impedance reading is compatible with the value given in the relevant table; - Check correct connection of AQUA CARE 2 solenoid valve; - Check correct impedance value of AQUA CARE 2 solenoid valve; - Renew AQUA CARE 2 solenoid valve; - Check for impedance on wiring connector J2 pins 4 and 6; - Renew lamps;
Table - New Platform 2005 Electronic Refrigerators, combination and double-door F21 F23 F28 NTC ambient probe UI FRIDGE Air NTC probe open / short circuit FRIDGE Evaporator NTC probe open / short-circuit F24 FREEZER Air NTC probe open / short-circuit F25 F40 F41 F42 F43 F44 F45 F46 F47 F49 F50 F51 F52 F53 FREEZER Evaporator NTC probe open / short-circuit CCZ Air NTC probe open / shortcircuit Display PCB does not work ON/OFF button does not work I Care button does not work Holiday button does not work ICE PARTY button Ever Fresh button Super Freeze button Super Cool button Alarm button FRIDGE + button FRIDGE - button CCZ button FREEZER + button FREEZER - button - Check NTC probe, ensuring that the impedance value read on pins 3 and 4 of - Check NTC probe, ensuring that the impedance value read on pins 1 and 2 of - Check NTC probe, ensuring that the impedance value read on pins 5 and 6 of - Check NTC probe, ensuring that the impedance value read on pins 1 and 2 of - Check efficiency of contacts on connector J12 on the PCB; - Check NTC probe, ensuring that the impedance value read on pins 3 and 4 of 5/5